Home

User Manual UM1008-1

image

Contents

1. carefully isolated from various human and mouse tissues CirmBlots Blots are prepared by transferring gel fractionated mRNA to a positively charged nylon membrane which ensures the complete transfer of even long messages We assured the transfer of the largest transcript 9 Kb CirmBlots blots provide greater sensitivity than ordinary Northern Blots CirmBlots Blots RNA are concentrated to a small area by using specially designed combs A lane of marker which sizes are 281 725 955 1383 1908 2604 4981 and 6583 bases is included on each CirmBlots blot CirmBlots Northern Blots give maximum sensitivity and utility They can be stripped and re probed several times Most of the CirmBlots contain 2 5 ug of poly A RNA from human or mouse tissue CirmBlots Blots have been clipped in the top left hand corner to provide an orientation for the markers and RNAs Note diagram on the following page for RNAs orientation To Obtain more CirmBlots Blots information and CirmBlots publications please Visit www cirmblots com CirmBlots Pre Made Multiple Tissue Northern Blots 3 WW CIRMBLOTS COM CirmBlots Multiple Tissue Northern Blots User Manual UM 1008 1 Revised J an 2004 ll List of Components Stored unused CirmBlots Blots at room temperature in a sealed plastic bag away from light Store Used CirmBlots Blots at 4 C in a sealed plastic bag until needed Store control probe at 20 C 1 CirmBlots Northern Blot Pre
2. wash shake off excess solution with forceps do not blot dry and wrap the blot immediately with plastic wrap When reprobing uncover the blot immediately place it in heated sterile water containing 0 5 SDS and follow the rest of the protocol provided for removing probes If the membrane has not partially dried see Section A above E Signal Decreases after two reprobings This problem is especially common for low abundance genes You may not see signals as strong as those observed for high abundance transcripts such as actin CirmBlots Pre Made Multiple Tissue Northern Blots 10 WW CIRMBLOTS COM
3. CirmBlots Multiple Tissue Northern Blots User Manual UM 1008 1 Revised J an 2004 CirmBlots A Technologies Advancement Company Multiple Tissues Northern Blots User Manual UM 1008 1 Revised Jan 2004 For Research Use Only CirmBlots Pre Made Multiple Tissue Northern Blots 1 WW CIRMBLOTS COM CirmBlots Multiple Tissue Northern Blots User Manual UM 1008 1 Revised J an 2004 Table of Contents Page l Introduction 3 ll List of Components 4 lll Preparation of Additional Solutions Required 5 IV CirmBlots Blots Orientation Lanes Identification 6 V Hybridization of CirmBlots Blots 7 VI Protocol 8 Vil Trouble Shooting Guide 9 CirmBlots Pre Made Multiple Tissue Northern Blots 2 WW CIRMBLOTS COM CirmBlots Multiple Tissue Northern Blots User Manual UM 1008 1 Revised J an 2004 I Introduction CirmBlots Blots are ready to hybridize Multiple Tissue Northern Blot optimized for intact mRNA and maximum sensitivity CirmBlots Blots can be used for the relative quantitative or and specific messages to assess gene expression across all tissues Identifying alternative spliced transcripts and to determine the size of specific messages CirmBlots premium quality pre made blots allow the user to precede a rapid gene expression analysis without the time consuming inconvenience of RNA isolation gel preparation and transfer procedures CirmBlots Multiple Tissue Northern Blots contain 2 5 ug of poly A RNA per lane The RNAs are
4. a width 5 5 cm Front of Northern Blot Back of Northern Blot Nucleic acid on the side Nucleic acid on other side CirmBlots Pre Made Multiple Tissue Northern Blots 7 WW CIRMBLOTS COM CirmBlots Multiple Tissue Northern Blots User Manual UM 1008 1 Revised J an 2004 VI Protocol l Hybridization e Prehybridization membrane for 1 4 hours at 42 C with 5 10 ml Prehybridization buffer e Heat labeled probe for 3 minutes at 95 C cool on ice e Discard Prehybridization buffer add hybridization buffer and probe incubate at 42 C at least 8 hours e Wash membrane 1 x 15 minutes with 2 x SSC at room temperature e Wash membrane 2 x 15 minutes with 2 x SSC with 0 1 SDS at 65 C e Wash membrane 1 x 15 minutes with 0 1 x SSC with 0 1 SDS at 65 C optional e Wrap the membrane with saran wrap and expose film at 80 C overnight Note Never let the membrane dry until the blot is stripped If you are using hybridization bottles make sure that the marked side of the membrane is flush against the side of the bottle Bubbles between the membrane and the bottle can prevent hybridization to those areas ll Stripping and Rehybridization e Wash membrane for 0 5 3 hours in strip solution at 70 80 C until on radioactivity can be detected on the membrane e The membrane can now be air dried and stored at room temperature e For rehybridization several times following the hybridization protocol CirmBlots Pre Made Multiple Tissu
5. e Northern Blots 8 WW CIRMBLOTS COM CirmBlots Multiple Tissue Northern Blots User Manual UM 1008 1 Revised J an 2004 Vil Troubleshooting Guide A High background Lengthening the time of low or high stringency washes rarely decreases high background signals Remove the probe from the blot as you would for reprobing Monitor the process with a Geiger counter to verify com is reduced to almost background levels If there is still a high background store the blot covered in plastic wrap at 20 C for 2 3 half lives The half life of 3P is 14 days High background can occur for several reasons Unincorporated 3P dNTPs are not fully removed from the probe Check the ratio of TCA precipitable cpm to total cpm in the final probe preparation Adjust chromatography conditions to achieve a ratio of gt 95 We also recommend purifying your hybridization probe by exclusion chromatography Average size of the DNA probe is too large Optimal sizes range from 200 800 nucleotides Increase the ratio of random primers to template DNA Concentration of probe in hybridization solution is too high For DNA probes do not exceed 2 x 10 cpm ml For oligonucleotide probes do not exceed 5 x 10 cpm ml B Hybridization signals absent or very weak If signals are not generated after 1 2 days of x ray film exposure the hybridization probe may have a low specific activity Make a new probe with fresh P The specific activity of your probe shou
6. ld always be gt 5 x 10 cpm ug and for maximum sensitivity gt 1 x 10 cpm ug If specific activity is still low upon repeating the labeling you may be using too little DNA We use 25 50 ng measured from the ODz60 of a concentrated stock If you have a small quantity of DNA electrophorese the amount you have been using on an agarose gel next to a known amount of DNA markers and estimate the amount of probe DNA If a clear ethidium bromide stained band is not observed you have less than 25 50 mg and therefore should use 2 3 times more DNA for probe labeling If this fails optimize labeling conditions with a known amount of control probe such as P actin CirmBlots Pre Made Multiple Tissue Northern Blots 9 WW CIRMBLOTS COM CirmBlots Multiple Tissue Northern Blots User Manual UM 1008 1 Revised J an 2004 C Probe not fully homologous to target If you are using a cross species probe you may need to reduce the stringency of your final wash by using Wash Solution 1 instead of Wash Solution 2 and decreasing the temperature by 5 10 C When using a synthetic oligonucleotide probe ensure that the probe is completely homologous to the target D Inability to strip and reprobe If you are unable to reprobe the blot the membrane may not have been stripped completely or may have been allowed to dry or partially dry If a membrane is allowed to even partially dry subsequent removal of the probe may be impossible To prevent drying after your final
7. mium Quality RNA e 25 ml Hybridization Solution CirmBlots Pre Made Multiple Tissue Northern Blots 4 WW CIRMBLOTS COM CirmBlots Multiple Tissue Northern Blots User Manual UM 1008 1 Revised J an 2004 lll Preparation of Additional Solutions Required DEPC Water o 50 mM NaOH 10 mM NaCl 0 1 Tris Cl pH 7 4 e 20X SSC 3 M NaCl 0 3 M Sodium Citrate pH 7 0 To Prepare 20X SSC Solution 1 Dissolve 173 3 g NaCl and 88 2 g of Sodium Citrates in 800 ml of DEPC water 2 Adjust the pH to 7 0 with a few drops of the 10NaOH solution of the concentrated Acetic Acid 3 Adjust the volume to 1 liter 4 Autoclave o Wash Solution 1 2X SSC 0 05 SDS Wash Solution 2 0 1X SSC 0 1 SDS CirmBlots Pre Made Multiple Tissue Northern Blots 5 WW CIRMBLOTS COM CirmBlots Multiple Tissue Northern Blots User Manual UM 1008 1 Revised J an 2004 IV CirmBlots Blots Orientation Lanes Identification Lanes are in the following orientation order left to right e g CirmBlots item HBO2 1 Markers 2 Heart 3 Brain 4 Placenta 5 Lung 6 Liver 7 Skeletal Muscle 8 Kidney 9 Pancreas Sample RNA Lanes Blot Numbering 123456789 e length 7 cm 2 e width 5 5 cm width 5 5 cm All CirmBlots products are sold for intended for research use only unless otherwise indicated CirmBlots products are not intended for diagnostic or drug purposes CirmBlots Pre Made Multiple Tissue N
8. orthern Blots 6 WW CIRMBLOTS COM CirmBlots Multiple Tissue Northern Blots User Manual UM 1008 1 Revised J an 2004 V Hybridization of CirmBlots Blots A To Hybridize CirmBlots 1 Remove the CirmBlots from the sealed plastic bag 2 Add sufficient pre warmed Hybridization Solution to keep the blot uniformly wet and Prehybridize at the desired hybridization temperature 3 Add probe to the hybridization solution hybridize the CirmBlots Blots at the desired hybridization temperature Generally we recommend the use of 1 x 10 cpm ml of DNA or RNA probe 1 10 pM nonisotopic DNA probe or 0 1 nM nonisotopic RNA probe The hybridization time is typically overnight depending on the type of hybridization buffer used and the abundance of the target and type of probe used RNA or DNA 4 Perform the post hybridization washes Generally the post hybridization washes are performed at the hybridization temperature for times empirically determined to give optimal specific signal to background signal ratios We recommend two low stringency washes of 15 minutes each and two high stringency washes of 15 minutes each 5 Expose the blot to X ray film 3P probe in a cassette For nonisotopic detection follow the kit or reagent manufacture s directions 6 The following diagrams indicated CirmBlots RNA and Lanes locations Sample RNA Lanes Blot Numbering 123456789 e length 7 cm e e width 5 5 cm

Download Pdf Manuals

image

Related Search

Related Contents

Hama VPL-CX76 Projector User Manual  Sanyo POA-RCKIT03 projector accessory  Preguntas Generales Preguntas acerca de la  BAUINVENTAR.kfz - MobileLocationController » Anmeldung  BATERÍA RECARGABLE Manual de Usuario 1  PORTA-DAVIT 500    Samsung Система за домашно кино HW-E350 Наръчник за потребителя  guia pluria - HTM Eletrônica  Manuel d`utilisation Kit de Changement de pile  

Copyright © All rights reserved.
Failed to retrieve file