Home
KAM Laserscan 1000 3D Manual
Contents
1. Pattern list DMX 1 TA ce es te rs Eres 176 191 192 207 208 223 224 239 240 255 Specifications Mains Input AC100 240V 50 60Hz 250V 1 6A Slow Blow 20mm Glass 40w 20 Audio Sound Activated 100mW 638nm red laser Laser Power 80mW 532nm green laser 300mW 450nm blue laser NettWeight 4 2Kg S O Laser Classification Class 3B 10
2. FUNC UP DOWN ENTER I Note In DMX MODE once the DMX cable is connected to the laser and DMX controller the DMX LED in front panel of laser will be ON Controlling units via DMX each unit uses 19 DMX channels To set the DMX address 1 Press the function button until is displayed range 001 512 2 Using the up down buttons select the desired DMX starting address 3 Press the enter button to confirm 4 Continue this formula to address any additional units Note on setting the DMX address of units If one or several units are to be controlled at the same time with the same features set all units DMX address to the same value Example all units to 001 If individual control of several units is required each unit must have its on unique address and no channels must cross Example unit 1 set to 001 unit 2 to 020 etc adding 19 clear channels each time Master slaving units with no DMX controller Set the master unit to the desired setting Example auto or sound Set all other units to slave mode To set slave mode press the function button until SLA is displayed then press the enter button to confirm Only one unit must be set as a master and all other units must be set as slave Connect each unit together via a 3pin DMX lead PATTERN MIRROR REVERSE SETTING FIG A e Press FUNC to enter the MODE selection D T e Use the up down buttons to set the LED display to iT match Fig A E e Press ENTER to confirm the setting Si an
3. INSTRUCTION MANUAL LASERSCAN 1000 3D Exceptional 3D ILDA laser with 5 different effects in a single unit MANUAL VERSION 1 0 10 04 71 2 Due to continuous product development please ensure that you have downloaded the latest instruction manual for this product from the Kam website at www kam co uk For the latest instruction manual updates and information on the entire Kam range visit www kam co uk Kam products are manufactured by Lamba plc Unit 1 Southfields Road Dunstable Bedfordshire United Kingdom LU6 3EJ Telephone 44 0 1582 690600 Fax 44 0 1582 690400 Email mail lambaplc com Web www lambaplc com If this product is ever no longer functional please take it to a recycling plant for environmentally friendly disposal Due to continuous product development specifications and appearance are subject to change Copyright Lamba plc 2010 E amp OE Thank you for purchasing this KAM product we are sure that it will serve you for many years to come To optimise the performance of this product please read these operating instructions carefully to familiarise yourself with the basic operations of this unit After you have read the instructions please retain them for future reference This unit has been tested at the factory before being shipped to you To prevent or reduce the risk of electrical shock or fire do not expose the unit to rain or moisture To prevent a fire hazard do not expose the unit to a
4. de Option to choose the operating mode of laser Stand alone mode pre programmed effect Automatically cycle through its built in programs This mode will only show the in air effects Automatically cycle through the built in 3D effects Automatically cycle through the built in traditional beam effects Automatically cycle through the built in northern lights effects Automatically cycle through the built in gratings effects Automatically cycle through the built in 3D universe effects UT Cycle through its built in programs by sound activation This mode will only show the in air effects SUO SOUND ACTIVATION MODE Sound sensitivity The laser has a built in microphone and to reduce and increase the sensitivity of the pick up which will alter the reaction of the programs use the Sound activation mode settings e Press FUNC till you see S6 e Press UP DOWN to set the microphone sensitivity S 0 is no sound activation from S 1 to S 9 the sensitivity level will increase and be more sensitive e Press Enter to confirm ATTENTION In pre programmed standalone MUSIC SHOW mode the laser beam will black out in 3 seconds without AUDIO MIC activated signal DMX MODE e Press FUNC to enter the MODE selection e The LED panel will show 001 for DMX mode e Press ENTER to confirm the setting DMX 512 Now the laser is working in DMX mode Sa f we Use the up down buttons to select the DMX address 8
5. ii Ai e 6 FUNC UP DOWN ENTER FIG B e Using the up down buttons set the LED display to match X Fig B This will rotate the graphic in the X direction S DMX 512 vf e 6 O FUNC UP DOWN ENTER FIG C e Using the up down buttons set the LED display to match DMX 512 Fig C This will flip the graphic in the Y direction w P L i FUNC UP DOWN ENTER ILDA Control Mode This unit has the ILDA DB25 port which allows control of the laser via a PC Mac laser or lighting software The PC must be connected to an interface and then the ILDA cable from the interface is connected to the ILDA input socket on the rear of the laser When connecting the ILDA plug to the laser this will override all built in standalone functions of the laser and can then only be controlled by the PC Mac software Removing the ILDA cable will re enable all standalone functions Please note it should be possible for any ILDA controlled software to operate this laser if your software is having problems controlling the laser this maybe down to a cable connection issue Some interfaces and cables may have different wiring configuration The fourth and seventeenth pin of the ILDA socket need to be connected If you rectify this issue on your interface then this will cure the control issue DMX Channels Chart Several operating modes were pre programmed into this laser projector on DMX channel 1 To enable full DMX control channel 1 must be set to DMX contro
6. l mode and have a value of 250 255 this will enable the rest of the DMX channels DMX channels chart when ILDA is connected Function o O 000 004 No grating rotating 005 127 Clockwise grating rotating cat Slatin ave 128 133 No grating rotating 134 255 Anticlockwise grating rotating 000 031 Laser 3D Effect 032 063 Scanned Beam Effect Pattern Effect 064 095 Laser Lumina Effect J gt lt O Q gt gt 2 n O Q gt D gt O gt 7 O O gt D O F D Q Function Laser OFF AUT Auto Show with Mixed 5 effect A3D Laser 3D Effect Auto Show AUB Scanned Beam Effect Auto Show AUL Laser Lumina Effect Auto Show AUN Burst Grating Effect Auto Show AUO Laser Universal Effect Auto Show SOU Sound Show with Mixed 5 Effect S3D Sound show with LASER 3D SOB Sound show with Scanned Beam SOL Sound show with LASER LUMIA SON Sound show with Burst Grating SOO Sound show with Laser Universal DMX MODE 1 Group Patterns 2 Group Patterns 3 Group Patterns 4 Group Patterns 5 Group Patterns Every 16 for 1 Group total 16 patterns Original Value 000 018 019 036 037 054 055 072 073 090 091 108 109 126 127 144 145 162 163 180 181 198 199 216 217 234 235 255 000 051 052 103 104 155 156 207 208 255 000 255 000 007 008 015 016 023 024 031 032 039 040 047 048 055 056 063 064 111 112 159 160 127 208 255 Channel CH 1 Mode CH 2 Gro
7. ny naked flame sources Unplug this apparatus during lightning storms or if it is unlikely to be used for long periods of time When installing the unit please ensure you leave enough space around the unit for ventilation Slots and openings in the unit are provided for ventilation to ensure reliable operation of the product and to protect it from overheating To prevent fire hazard the openings should never be blocked or covered Always handle the power cable by the plug Never pull out the plug by pulling on the cable Never touch the power cable when your hands are wet as this could cause an electric shock Do not tie a knot in the cable The power cable should be placed such that it is not likely to be stepped on A damaged power cable can cause a fire or give you an electrical shock Check the power cord periodicaly if you ever find that it is damaged replace it before using the unit again Contact your retailer for a replacement The voltage of the available power supply differs according to country or region Be sure that the power supply voltage of the area where this unit is to be used meets the required written on the unit CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN The lightning flash symbol inside a triangle is intended to alert the user to the presence high voltage within the unit s enclosure that may be of sufficient power to constitute a risk of electrical shock to persons Caution to prevent the risk of electric shock d
8. o not attempt to open the unit No user serviceable parts inside Refer all servicing to qualified service personnel The exclamation mark inside a triangle is intended to alert the user to the presence of important operating and maintenance instructions in the literature accompanying the appliance Any modification carried out on the unit may invalidate the unit s warranty lf applicable only use the stand tripod or bracket specified or sold with the apparatus Select the installation location of your unit carefully Avoid placing it in direct sunlight or locations subject to vibration and excessive dust Do not use the unit where there are extremes in temperature below 41 F 5 C or exceeding 95 F 35 C Unpacking and safety Please unpack your new product carefully your new product should reach you in perfect condition Please check that no damage has occurred during transit If any damage is found do not operate your unit Please contact the retailer you purchased it from immediately If there is any damage to the mains cable do not use the device Always disconnect the unit from the mains supply when carrying out any servicing or cleaning of the unit The serial number for this equipment should be located on the rear or underside of the unit Please make a note of this number as you will need it for your warranty it is a good idea to keep a copy of the serial number for your own records Unpacking instructions CAUTION Immediately
9. performance y NA lt gt D 2 A aana of procedures other than what is specified Vo el ee herein may result in hazardous radiation Y e o y i n etal i as E Ss exposure r DHO n J o Front Panel os 1 Laser output Laser output aperture BrT Laserscan 2 Power Red LED is ON i 1000 3D 3 Music Synchronise to detected music signal j SS as LIGHTING G 0e skin exposure to direct or scattered radiation D 1 Rear Panel amma wn 08 3 9 KEEP THIS OUTPUT FREE AND CLEAR CHAIN O O Nida 6 REMOTE ILDA THROUGH FUNCTION SETTING ON Kp z gi G r ILDA INPUT TRR ge O O P pacan OL IGH TIN G MER BA www kam co uk 5 OO 4 Switch Power on and off 10 Cooling fan Never cover the fan 5 Mains input with intergrated fuse holder 11 Safety eye Attach the safety cable 6 DMX input 3 PIN Male XLR 12 LED function displaY 7 DMX output 3 PIN Female XLR 13 Safety switch turns unit off immediately 8 ILDA input Standard ILDA DB25 input 14 Key switch 9 ILDA through Standard ILDA DB25 output Operating Mode When the laser is powered on the LCD monitor on rear panel shows the current operating standalone mode DMX address or Slave mode With help of the LCD control panel it is very easy to set and change the operating mode of the laser The next time the laser is powered on it will show the last setting used before the laser was powered off FUNC Mo
10. up CH 3 Pattern Green Yellow Blue Purple Light Blue White Colour Rolling Colour Jumping Colour Moving Strobing Full pattern without clipping 001 127 0 99 fixed pattern clipped 128 255 Clipping Speed 000 127 100 5 fixed pattern zoomed 128 169 Zooming IN 170 209 Zooming OUT 210 255 Alternately Zooming 000 255 Fast to Slow 000 127 0 359 degree fixed Y axis rolled 128 191 Clockwise rolling 192 255 Anticlockwise rolling 0 255 Fast to Slow 000 127 0 359 degree fixed X axis rolled 128 191 Clockwise rolling 192 255 Anticlockwise rolling 0 255 Fast to Slow 000 127 0 359 degree fixed Z axis rolled 128 191 Clockwise rolling 192 255 Anticlockwise rolling 0 255 Fast to Slow 000 127 128 different fixed position on X axis 128 191 Clockwise moving 192 255 Anticlockwise moving 0 255 Fast to Slow CH 4 Colour CH 5 Clipping CH 6 Zooming CH 7 Zoom speed CH 8 Y Axis rolling CH 9 Roll speed CH 10 X Axis rolling CH 11 Roll speed CH 12 Z Axis Rolling CH 13 Roll speed CH 14 Y Axis moving CH 15 Move speed 000 127 128 different fixed position on Y axis CH 16 X Axis moving 128 191 Clockwise moving 192 255 Anticlockwise moving CH 17 Move speed 0 255 Fast to Slow 000 004 No grating rotating 005 127 Clockwise grating rotating el TE ote rotano 128 133 No grating rotating 134 255 Anticlockwise grating rotating 096 127 te E
11. upon receiving a fixture carefully unpack the carton check the contents to ensure that all parts are present and have been received in good condition Notify the shipper immediately and retain packing material for inspection if any parts appear damage from shipping or the package itself shows signs of mishandling Save the package and all packing materials In the event that a fixture must be returned to the factory it is important that the fixture be returned in the original factory box and packing Contents 1 x Laser 2 x Keys 1 x Interlock connector and 1 x Power cord Power Supply Cable EU Cable US Pin International FUSE 5mmx20mm LightBlue White Neutral N N j i TEEN mom omn tm l O DMX 512 connection between fixtures The fixture is equipped with 3 pin XLR sockets for DMX input and output The sockets are wired in parallel Only use a shielded twisted pair cable designed for 3 pin XLR plugs and connectors in order to connect the controller with the fixture or one fixture with another XLR connection DMX output DMX input XLR mounting sockets rear view XLR mounting plugs rear view 1 Shield 2 Signal 3 Signal Building a serial DMX chain DMX 512 Controller operation Master slave ai ysl operation e lf you are using a standard DMX controller you can connect the DMX output of the controller directly with the DMX input of the first fixture in the DMX chain If you
12. wish to connect DMX controllers with other XLR outputs you need to use adapter cables DMX controller not supplied e Connect the DMX output of the first fixture in the DMX chain with the DMX input of the next fixture Always connect output with the input of the next fixture until all fixtures are connected e lf you use a controller with 5 pins DMX connector you need to use a 5 to 3 pins adapter e The DMX output and input connectors are pass through to maintain the DMX circuit when power is disconnected to the unit e Each fixture needs to have a DMX address to receive the data from the controller The DMX address number which could be read from rear panel of each fixture is between 000 511 Proper laser set up amp usage This fixture has been designed to be hung It is recommended for safety purposes your lighting effect are properly mounted using a Suitable hanging clamp and safety cable Items appropriate for safe and effective mounting are easily sourced from your lighting vendor International laser safety regulations require that lasers must be operated in the fashion illustrated below with a minimum of 3 meters 9 8 ft of vertical separation between the floor and the lowest laser light vertically Additionally 2 5 meters of horizontal separation is required between laser light and audience or other public spaces 3 Meters Adjust Angle 5 TUEA I A p r o D At nane S f A CAUTION Use of controls adjustments or