Home
Neutron Engineering Inc.
Contents
1. 3248 _ Polarization 1 186Hz 4058 _ Our calculated Measurement Instrumentation Uncertainty is shown the tables above These are our Uy values in CISPR 16 4 2 terminology Since Table 1 of CISPR 16 4 2 has values of measurement instrumentation uncertainty called Ucispr as follows Conducted Disturbance mains port 150 kHz 30 MHz 3 6 dB Radiated Disturbance electric field strength on an open area test site or alternative test site 30 MHz 1000 MHz 5 2 dB It can be seen that our Uab values are smaller than Report No NEI FCCE 1 1403073 Page 7 of 27 Neutron Engineering Inc 3 GENERAL INFORMATION 3 1 GENERAL DESCRIPTION OF EUT Equipment MotherBoard Model Name ARM C2 DEP details of EUT technical specification please refer to the User s Manual DC Voltage supplied from DC Source Note 1 For a more detailed features description please refer to the manufacturer s specifications or the User s Manual Report No NEI FCCE 1 1403073 Page 8 of 27 Neutron Engineering Inc 3 2 DESCRIPTION OF TEST MODES To investigate the maximum EMI emission characteristics generates from EUT the test system was pre scanning tested base on the consideration of following EUT operation mode or test configuration mode which possible have effect on EMI emission level Each of these EUT operation mode s or test configuration mode s mentioned above was evaluated r
2. 37 Lane 365 YangGuang St NeiHu District 114 Taipei Taiwan TEL 886 2 2657 3299 Gow FAX 886 2 2657 3331 Report No NEI FCCE 1 1403073 Page 1 of 27 Neutron Engineering Inc Declaration Neutron represents to the client that testing is done in accordance with standard procedures as applicable and that test instruments used has been calibrated with the standards traceable to National Measurement Laboratory NML of R O C or National Institute of Standards and Technology NIST of U S A Neutron s reports apply only to the specific samples tested under conditions It is manufacture s responsibility to ensure that additional production units of this model are manufactured with the identical electrical and mechanical components Neutron shall have no liability for any declarations inferences or generalizations drawn by the client or others from Neutron issued reports Neutron s reports must not be used by the client to claim product endorsement by the authorities or any agency of the Government This report is the confidential property of the client As a mutual protection to the clients the public and Neutron self extracts from the test report shall not be reproduced except in full with Neutron s authorized written approval Neutron s laboratory quality assurance procedures are in compliance with the ISO Guide 17025 requirements and accredited by the conformity assessment authorities listed in this test rep
3. 4 1 7 TEST RESULTS EUT 2 Relative Humidity Test Voltage AC 120V 60Hz FULL SYSTEM 100 0 5 h 3 Phase Line Limil AWG mm Em rcc Apr 00 0 150 05 MHz 30 000 Reading Corect Measure Mk Freg Level Factor ment Limit Over MHz dBuV dB dBuV dBuV dB Detector Comment 1 0151 4263 973 5236 7900 26 64 peak 2 0 1913 4069 10 09 5078 1900 2822 peak 3 0 25 8 34 64 9 85 4449 7900 3451 4 0 3322 2990 9 72 3962 7900 3938 peak 5 98000 2257 971 3228 73 00 4072 peak 6 202500 2387 10 19 3406 73 00 38 94 peak Report No NEI FCCE 1 1403073 Page 15 of 27 Neutron Engineering Inc EUT MotherBoard Model Name 2 Relative Humidity Test Voltage AC 120V 60Hz FULL SYSTEM 100 0 WW hy 1 WAP nre tdmen n Phase Neutral Limi 0 0 0 150 MHz 5 30 000 Reading Corect Measure 0 No Mk Freq Level Factor ment Umit Over MHz dB dBuV dBuV de Detector Comment 1 0 1563 41 62 9 75 51 37 7900 27 63 peak 2 0 1920 40 95 10 08 51 03 1900 27 97 peak 3 0 2555 3410 9 85 4395 1 00 35 05 peak 4 0 2858 2847 9 69 3816 7900 4084 peak B 0 3873 28 10 9 72 37 82 7900 41 18 peak 6 0 4573 2526 9 75 3501 7900 4399 Report NEI FCCE 1 1403073 Page 16 of 27 Neutron Engineering Inc 4 2 RADIATED EMISSION TEST 4 2
4. B1 No 37 Lane 365 YangGuang St NeiHu District 114 Taipei Taiwan Radiated emission Test Below 1 GHz 0501 VCCI RN R 2829 RN 95335 DN TW1010 132 1 Ln 329 Sec 2 Balian Xizhi Dist New Taipei City 221 Taiwan Radiated emission Test Above 1 GHz VCCI RN G 91 RN 614388 DN TW1054 IC Assigned Code 4428C 1 1F No 61 Ln 77 Sing ai Rd Neihu Dist Taipei City 114 Taiwan R O C 2 2 MEASUREMENT UNCERTAINTY The measurement uncertainty is not specified by FCC Industry Canada rules and for reference only The reported uncertainty of measurement y U where expended uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k 2 gt providing a level of confidence of approximately 95 The measurement instrumentation uncertainty considerations contained in CISPR 16 4 2 A Conducted emission test Measurement Frequency Range _ U gt dB NOTE 150 kHz 30 MHz 194 20 B Radiated emission test 4 Measurement Frequency Ant 30 MHz 200 MHz 286 0501 30 MHz 200 MHz 256 200 MHz 1 000 MHz V 288 200 MHz 1 000 MHz H 298 Test Site Measurement Frequency Range Uncertainty NOTE 30 200MH2 3358 Horizontal 200 1000MHz 341dB _ radiated Polatization 1 186 f 397dB 718 4064 _ gt 30 200MHz 3228 Vertical 200 100MHz
5. Horizontal 200 1000MHz 341dB _ radiated Polatization 1 18GHz f 397dB e a _ gt 30 200MHz 3228 Vertical 200 100MHz 3248 _ Polarization 1 186Hz 4058 _ Our calculated Measurement Instrumentation Uncertainty is shown the tables above These are our Uy values in CISPR 16 4 2 terminology Since Table 1 of CISPR 16 4 2 has values of measurement instrumentation uncertainty called Ucispr as follows Conducted Disturbance mains port 150 kHz 30 MHz 3 6 dB Radiated Disturbance electric field strength on an open area test site or alternative test site 30 MHz 1000 MHz 5 2 dB It can be seen that our Uab values are smaller than Report No NEI FCCE 1 1404241 Page 7 of 27 Neutron Engineering Inc 3 GENERAL INFORMATION 3 1 GENERAL DESCRIPTION OF EUT CPU MAINBOARD WITH ARM PROCESSOR Model Name ARM C2 FULL details of EUT technical specification please refer to the User s Manual DC Voltage supplied from DC Source Note 1 For a more detailed features description please refer to the manufacturer s specifications or the User s Manual Report No NEI FCCE 1 1404241 Page 8 of 27 Neutron Engineering Inc 3 2 DESCRIPTION OF TEST MODES To investigate the maximum EMI emission characteristics generates from EUT the test system was pre scanning tested base on the consideration of following EUT operation mode
6. Correct Factor Correct Factor Antenna Factor Cable Loss Amplifier Gain if use Margin Level Measurement Value Limit Value FREQUENCY RANGE OF RADIATED MEASUREMENT FOR UNINTENTIONAL RADIATORS Highest frequency generated or Upper frequency of measurement used in the device or on which the device operates or tunes MHz Below 1 705 Range MHz 1 705 108 1000 108 500 2000 500 1000 9000 harmonic of the highest frequency or Above 1000 40 GHz whichever is lower Report No NEI FCCE 1 1404241 Page 17 of 27 4 2 2 MEASUREMENT INSTRUMENTS LIST 1 GHz Kind of Equipment Type No Calibrated until Log Bicon Schwarzbeck VULB 9160 3173 Nov 28 2014 Jun 02 2014 a ts uma Jun 02 2014 Jun 02 2014 5 EMI Test Receiver Receiver R amp S Mar 20 2015 System Controller or TurnTable Table Chance Most Most 5 1 5 Software Version NB 03A Above 1 GHz Kind of Equipment Type No Calibrated until 1 Pre Amplifier Agilent 8449B 3008A01714 Apr 15 2015 HARBOUR E Microflex Cable INDUSTRIES 2 478 LL142 May 13 2014 Microflex Microflex Cable AS S104 SMAP 1 1 10M May 15 2014 Microflex Cable mm 27478 LL142 utn May 13 2014 5 SpectrumAnalzr R amp S FSP 40 100129 20 2014 DA Softwar
7. Limits and then QP Mode measurement didn t perform NOTE Above 1 GHz a Reading in which marked as Peak means measurements by using are Peak Mode with instrument setting in RBW 1 MHz VBW 1 MHz Reading in which marked as AV means measurements by using are Average Mode with instrument setting in RBW 1 MHz VBW 10 Hz b All readings are Peak Mode value unless otherwise stated AVG in column of Note If the Peak Mode Measured value compliance with the Peak Limits and lower than AVG Limits the EUT shall be deemed to meet both Peak amp AVG Limits and then only Peak Mode was measured but AVG Mode didn t perform Report No NEI FCCE 1 1404241 Page 19 of 27 destin A 2 Neutron Engineering Inc 4 2 4 DEVIATION FROM TEST STANDARD No deviation 4 2 5 TEST SETUP Below 1 GHz Stand alone device Ground Plane Test Above 1 GHz Stand alone device Spectrum Analyzer Amp 4 2 6 EUT OPERATING CONDITIONS The EUT tested system was configured as the statements of 4 1 6 Unless otherwise a special operating condition is specified in the follows during the testing Report No NEI FCCE 1 1404241 Page 20 of 27 destin 1 5 2 0 4 2 7 TEST RESULTS BELOW 1 GHZ CPU MAINBOARD WITH ARM PROCESSOR Temperature ARM C2 FULL 21 C felative Humidity _ EE Test Mode FULL SYSTEM 30 0 dBuM m 40 30 000 127 00 No Freq MHz 1 67 5080 2 81 0
8. data in this report Conducted emission Test C01 VCCI RN C 2918 RN 95335 TW1010 132 1 Ln 329 Sec 2 Balian Xizhi Dist New Taipei City 221 Taiwan Radiated emission Test Below 1 GHz 0502 VCCI RN R 2669 RN 95335 DN TW1010 132 1 Ln 329 Sec 2 Balian Xizhi Dist New Taipei City 221 Taiwan Radiated emission Test Above 1 GHz VCCI RN G 91 614388 DN TW1054 IC Assigned Code 4428C 1 1F No 61 Ln 77 Sing ai Rd Neihu Dist Taipei City 114 Taiwan R O C 2 2 MEASUREMENT UNCERTAINTY The measurement uncertainty is not specified by FCC Industry Canada rules and for reference only The reported uncertainty of measurement y U where expended uncertainty U is based on a standard uncertainty multiplied by a coverage factor of k 2 gt providing a level of confidence of approximately 95 The measurement instrumentation uncertainty considerations contained in CISPR 16 4 2 A Conducted emission test Test Site Measurement Frequency Range gt dB NOTE 150 kHz 30 MHz 194 B Radiated emission test 4 Measurement Frequency Ant 30 MHz 200 MHz 248 0502 30 MHz 200 MHz 216 200 2 1 00 V 250 200MHz 1 000MHz H 266 Test Site Measurement Frequency Range Uncertainty NOTE 30 200MHz 3358
9. from it during test It is however continuously scanned for data input activity Report No NEI FCCE 1 1404241 Page 14 of 27 Neutron Engineering Inc 4 1 7 TEST RESULTS CPU MAINBOARD WITH ARM ARM C2 FULL Relative Humidity Test Voltage AC 120V 60Hz FULL SYSTEM Phase Line 1000 2 50 n Rule nsa 0 0 0 150 0 5 MHz J 30 000 Reading Measure 0 No Freq Leve Factor ment Limit Over MHz Detector Comment 1 01528 46 64 973 5637 79 00 2263 2 0 1920 4436 1014 5450 79 00 2450 peak 3 04510 30 20 971 39 91 79 00 3909 4 12290 25 75 965 3540 73 00 37 60 peak 5 10 1500 23 82 990 33 72 73 00 3928 6 24 0000 28 06 985 37 91 73 00 35 09 peak Report No NEI FCCE 1 1404241 Page 15 of 27 y y Neutron Engineering Inc CPU MAINBOARD WITH ARM ARM C2 FULL Relative Humidity 120V 60Hz Test Voltage Test Mode 100 0 LT adeat 0 0 0 150 Freq MHz 0 1661 0 2417 0 6690 2 7139 9 2500 24 0000 F Level dBuV m 44 63 37 91 27 07 21 49 22 28 31 19 0 5 ULL SYSTEM Factor 9 86 9 96 9 62 9 70 9 67 9 88 Report No NEI FCCE 1 1404241 Phase Neutral Reading Correct Measure ment 54 49 Af 87 36 69 31 19 32 15 41 07 MHz L
10. or test configuration mode which possible have effect on EMI emission level Each of these EUT operation mode s or test configuration mode s mentioned above was evaluated respectively Mode 1 FULL SYSTEM Conducted emission test Mode 1 FULL SYSTEM Radiated emission test Mode 1 FULL SYSTEM Report No NEI FCCE 1 1404241 Page 9 of 27 E 5 Flash 2 Adapter E 3 E 4 Headset MP3 C 1 RJ 45 Cable 2 E 8 SD Card C 2 Power Cable E 9 Micro SD Card C 3 USB Cable C 4 Audio Cable 2 C 5 Audio Cable C 6 Data Cable C 7 Data Cable 4 Report No NEI FCCE 1 1404241 Page 10 of 27 3 4 DESCRIPTION OF SUPPORT UNITS The EUT has been tested as an independent unit together with other necessary accessories or support units The following support units or accessories were used to form a representative test configuration during the tests CPU MAINBOARD 1 WITH ARM AEN co ARM C2 FULL N A EUT PROCESSOR CN 09RRC7 44751 I os 323 myo g 4 958 Flash MP3 pp HVO4T 95NY781 Case MEMORY oP WM X YES NO 4 NO _________ ssj 1 The support equipment was authorized by Declaration of Conformity DOC Report No NEI FCCE 1 1404241 Page 11 of 27 4 EMC EMISSION TEST 4 1 CONDUCTED EMISSION TEST 4 1 1 LIMITS FREQUENCY RA
11. 0 Polarization Vertical 4000 00 Over dB 2T 58 35 06 41 08 40 93 38 19 34 70 4500 00 Detector peak peak peak peak peak ARM C2 DEP 62 5000 00 6000 00 MHz Comment Page 23 of 27 destin 9 Temperature Test Voltage Test Mode 100 0 dHuM m 1 h 2 M n 1000 000 1500 00 No Freq MHz 1 1087500 2 1450 000 3 2487500 4 3237500 5 4137500 6 46525000 2000 00 Reading Level dBuV 54 59 50 43 36 29 35 92 36 15 37 01 Factor 5 08 3 13 0 30 1 68 5 46 597 Report No NEI FCCE 1 1403073 S000 00 Measure ment dBuV m 49 61 47 30 36 59 37 60 41 61 42 98 2 Relative Humidity 62 Polarization Horizontal 58 3500 00 4100 00 4500 00 2000 00 6000 00 MHz Limit Over dBuV im dB Detector Comment 80 00 30 39 peak 80 00 32 70 peak 80 00 4341 peak 8000 4240 peak 80 00 38 39 peak 80 00 37 02 peak 24 of 27 Neutron Engineering Inc 5 EUT TEST PHOTO Conducted emission test photos FULL SYSTEM Report No NEI FCCE 1 1403073 Page 25 of 27 Radiated emission Below 1 GHz test photos FULL SYSTEM ee Report No NEI FCCE 1 1403073 Page 26 of 27 9 Radiated emission above 1 GHz test photos FULL SYSTEM WZ Report No
12. 080 3 121 4900 4 178 6000 5 250 0100 6 5000000 Report No NEI FCCE 1 1404241 Polarization Vertical 224 00 321 00 418 00 Heading X Correct Measure Level Factor ment dBuV dB dBuVim 33 75 5 33 26 42 41 57 f AS 34 14 41 37 4 25 37 12 43 16 5 26 37 90 43 98 9 94 38 44 38 18 0 92 39 10 515 00 Limit dBuV m 40 00 40 00 40 00 40 00 47 00 47 00 612 00 11 58 5 86 2 88 2 10 B 56 f 30 709 00 806 00 Detector QP peak peak peak peak peak Comment 1000 00 MHz Page 21 of 27 Testi 2 Neutron Engineering Inc CPU MAINBOARD WITH ARM PROCESSOR Model Name ARM C2 FULL 21 Relative Humidity AC 120V 60Hz Temperature Test Voltage Test Mode FULL SYSTEM Polarization Horizontal 300 3 d 00 30 000 127 00 224 00 321 00 418 00 515 00 512 00 709 00 806 00 1000 00 MHz Reading Comec Measure No Mk Freq Level Factor ment Limit Over MHz dBu Detector Comment 1 121 5160 39 15 4 24 34 91 40 00 5 09 2 176 5000 38 02 5 24 3278 40 00 7 22 3 250 0000 45 53 5 54 3999 4700 701 4 4642100 39 84 0 45 4029 4700 671 5 500 0000 41 08 0 92 4200 4700 5 00 6 1000 000 29 81 10 42 4023 4700 677 Report NEI FCCE 1 1404241 Page 22 of 27 Test CPU MAINBOARD WITH ARM Model Name ARM C2 FULL PRO
13. 1 LIMITS Below 1 GHz FREQUENCY MHz dBuV m dBuV m NOTE 1 The limit for radiated test was performed according to as following FCC Part 15 Subpart B 2012 ICES 003 Issue 5 2012 CAN CSA CISPR 22 10 CISPR 22 2008 2 The tighter limit applies at the band edges 3 Emission level dBuV m 20log Emission level uV m 4 The test result calculated as following Measurement Value Reading Level Correct Factor Correct Factor Antenna Factor Cable Loss Amplifier Gain if use Margin Level Measurement Value Limit Value Above 1 GHz FREQUENCY Class A dBuV m at 3m Class A dBuV m at 10m MHz PEAK AVERAGE PEAK AVERAGE Above 1000 80 60 695 495 FREQUENCY Class B dBuV m at 3m MHz PEAK AVERAGE Above 1000 NOTE 1 The limit for radiated test was performed according to as following FCC Part 15 Subpart B 2012 ICES 003 Issue 5 2012 2 The tighter limit applies at the band edges 3 Emission level dBuV m 20log Emission level uV m 3m Emission level 10m Emission level 20log 10m 3m 4 The test result calculated as following Measurement Value Reading Level Correct Factor Correct Factor Antenna Factor Cable Loss Amplifier Gain if use Margin Level Measurement Value Limit Value FREQUENCY RANGE OF RADIATED MEASUREMENT FOR UNINTENTIONAL RADIATORS Highest frequency generated or Upper frequency of measurement used in the device or on which the d
14. 183 7600 36 40 5 87 30 53 4000 94T peak 2499200 4319 6 08 37 11 47 00 9 89 6 301 2800 36 79 4 04 3275 4700 1425 peak Report NEI FCCE 1 1403073 Page 21 of 27 Neutron Engineering Inc EUT ARM C2 DEP Relative Humidity Test Voltage AC 120V 60Hz Test Mode FULL SYSTEM Polarization Horizontal 177 00 224 321 00 478 00 515 00 612 00 7049 00 80600 1000 00 Reading Corect Measure No Mk Freq Level Factor ment Limit Over MHz dBuV dBuvim dBuV m dB Detector Comment 1 822600 4410 1001 3409 4000 591 2 183 9000 3433 5 89 28 44 40 00 11 56 peak 3 249 7800 4100 6 08 3492 47 00 12 08 peak 4 301 4000 36 18 4 04 3214 47 00 14 86 peak 5 435 5000 30 79 1 08 29 71 47 00 17 29 peak 6 5024200 2998 0 41 30 39 47 00 16 61 peak Report No NEI FCCE 1 1403073 Page 22 of 27 esti 9 Temperature Test Voltage Test Mode 10 0 m 2 1000 000 1500 00 Mk Freq 1 2 3 2450 000 4 3475 000 5 4225 000 6 5837 500 Report No NEI FCCE 1 1403073 A000 00 Reading Level dBuV 57 50 48 07 36 77 36 35 36 27 37 24 zt 00 Factor 5 08 3 13 0 15 212 554 8 06 S000 Comect Measure ment 52 42 44 94 38 92 39 07 41 81 45 30 Relative Humidity 3500 00 dBuV m 60 00 60 00 60 00 60 00 60 00 60 0
15. CESSOR Temperature 25 Relative Humidity 162 Test Voltage AC 120V 60Hz Test Mode FULL SYSTEM Polarization Vertical 1000 dBuv m TT TT 0 0 1000 000 1500 00 000 00 200 3000 500 00 4000 00 4500 00 5000 00 6000 00 Reading Correct Measure No Mk Freq Level Factor ment Limit Over MHz dBuV dB dB Detector Comment 1 1137 500 50 40 4 82 45 58 80 00 34 42 2 1437 500 47 19 3 20 44 59 80 00 35 41 3 2362500 43 62 0 16 43 46 8000 3654 peak 4 3312500 4333 200 4533 8000 3467 5 3950 000 43 18 508 4826 8000 3174 peak 6 4525000 42 49 584 4833 8000 3167 peak Report NEI FCCE 1 1404241 Page 23 of 27 5 1 5 4 re Temperature Test Voltage Test Mode 100 0 dBuv m 0 0 1000 000 1500 00 Freq MHz 1 1087 500 2 1712500 2400 000 4 3062 500 J 3612 500 6 4475000 2000 00 Reading Level dBuV 46 54 42 89 43 37 43 53 43 88 42 76 2500 Correct Factor dB 5 08 2 28 0 03 0 69 3 39 arr Report No NEI FCCE 1 1404241 CPU MAINBOARD WITH ARM PROCESSOR 3000 00 Measure ment dBuV m 41 46 40 61 43 34 44 42 Af 27 48 53 3900 Limit dBuV im 80 00 80 00 80 00 80 00 80 00 80 00 4000 00 Over 38 54 39 39 36 66 35 58 32 73 3147 Model Name ARM C2 FULL Relative Humidity 62 xm 4500 00 2000 00 Detec
16. NEI FCCE 1 1403073 Page 27 of 27 Neutron Engineering Inc ATTACHMENT PHOTOGRAPHS OF EUT Project No 1403073 Page 1 of 3 Testy lt 5 Neutron Engineering Inc CEEE ETE ae oe um FSS 28508 ja LEE Tow Project No 1403073 Page 2 of 3 13 17 Neutron Engineering Inc Testi 5 i L i Project No 1403073 Page 3 of 3
17. NGE 150 KHZ 30MHZ FREQUENCY Class A dBuV Class dBuV 1 The tighter limit applies at the band edges 2 The limit of marked band means the limitation decreases linearly with the logarithm of the frequency in the range 3 The test result calculated as following Measurement Value Reading Level Correct Factor Correct Factor Insertion Loss Cable Loss Attenuator Factor if use Margin Level Measurement Value Limit Value 4 1 2 MEASUREMENT INSTRUMENTS LIST Kind of Equipment Type Calibrated until TWO LINE me ENV216 101050 Apr21 2015 Test TestCable TIMES CFD300 NL Jun 16 2014 B EMI Test Receiver R amp S 0 100082 Mar 20 2015 Measurement EZ Software Version NB 03A Remark N A denotes No Model Name No Serial No or No Calibration specified Report No NEI FCCE 1 1404241 Page 12 of 27 Neutron Engineering Inc 4 1 3 TEST PROCEDURE a The EUT was placed 0 8 meters from the horizontal ground plane with EUT being connected to the power mains through a line impedance stabilization network LISN All other support equipments powered from additional LISN s The LISN provide 50 Ohm 50uH of coupling impedance for the measuring instrument b Interconnecting cables that hang closer than 40 cm to the ground plane shall be folded back and forth in the center forming a bundle 30 to 40 cm long c cables that are not
18. ON Equipment CPU MAINBOARD WITH ARM PROCESSOR Brand Name CJB ARM C2 Model Name ARM C2 FULL Applicant C J B Computer Job Srl Date of Test Apr 18 2014 Apr 30 2014 Standard s FCC Part 15 Subpart B 2013 Class A ICES 003 Issue 5 2012 Class A CAN CSA CISPR 22 10 Class A CISPR 22 2008 Class A ANSI C63 4 2009 The above equipment has been tested and found compliance with the requirement of the relative standards by Neutron Engineering Inc EMC Laboratory The test data data evaluation and equipment configuration contained in our test report Ref No NEI FCCE 1 1404241 were obtained utilizing the test procedures test instruments test sites that has been accredited by the Authority of TAF according to the ISO 17025 quality assessment standard and technical standard s Report No NEI FCCE 1 1404241 Page 5 of 27 Neutron Engineering Inc 2 SUMMARY OF TEST RESULTS Test procedures according to the technical standards Ds ICES 003 Issue 5 2012 Radiated emission Below 1 GHz pass CAN CSA CISPR 22 10 H A PASS NTEU CISPR 22 2008 Radiated emission Above 1 GHz 2 NOTE 1 denotes test is not applicable in this Test Report 2 If the EUT s max operating frequency does not exceed 108 MHz the test will be performed Report No NEI FCCE 1 1404241 Page 6 of 27 Neutron Engineering Inc 2 1 TEST FACILITY The test facilities used to collect the test
19. ST PROCEDURE a The EUT was placed on the top of a rotating table 0 8 meters above the ground at a 3m or 10 meter open area test site The table was rotated 360 degrees to determine the position of the highest radiation The height of the equipment or of the substitution antenna shall be 0 8 the height of the test antenna shall vary between 1 m to 4 m Both horizontal and vertical polarizations of the antenna are set to make the measurement c The initial step in collecting radiated emission data is a spectrum analyzer peak detector mode pre scanning the measurement frequency range Significant peaks are then marked and then Quasi Peak detector mode re measured d If the Peak Mode measured value compliance with and lower than Quasi Peak Mode Limit the EUT shall be deemed to meet QP Limits and then no additional QP Mode measurement performed e For the actual test configuration please refer to the related Item EUT Test Photos NOTE Below 1 GHz a Reading in which marked as QP or Peak means measurements by using are Quasi Peak Mode with Detector BW 120 kHz b All readings are Peak unless otherwise stated QP in column of Note Peak denotes that the Peak reading compliance with the QP Limits and then QP Mode measurement didn t perform NOTE Above 1 GHz a Reading in which marked as Peak means measurements by using are Peak Mode with instrument setting in RBW 1 MHz VBW 1 MHz Reading in which marked as AV means measuremen
20. VERIFICATION This is to certify that the product listed in follows was were tested in the Neutron EMC Laboratory to comply with the criteria limits Class A of conducted and radiated emissions of the Technical Standards FCC Part 15 Subpart B established by the FCC USA Equipment Model Name Applicant Address Standard s Report s CPU MAINBOARD WITH ARM PROCESSOR ARM C2 FULL C J B Computer Job Srl Via Ghislandi 24 25125 BRESCIA ITALY FCC Part 15 Subpart B 2013 ANSI C63 4 2009 ICES 003 Issue 5 2012 CISPR 22 2008 CAN CSA CISPR 22 10 NEI FCCE 1 1404241 The test data data evaluation and equipment configuration contained in our test report s above was were obtained utilizing the test procedures test instruments test sites that has been accredited by the Authority of TAF according to the ISO 17025 quality assessment standard and technical standard s The test data contained in the referenced test report relate only to the EUT sample and item s tested Authorizeq Signatory Neutron Engineering Inc 2 B1 No 37 Lane 365 YangGuang St NeiHu District 114 Taipei Taiwan 7 TEL 886 2 2657 3299 886 2 2657 3331 VERIFICATION This is to certify that the product listed in follows was were tested in the Neutron EMC Laboratory to comply with the criteria limits Class A of conducted and radiated emissions of the Technical Standa
21. connected to a peripheral shall be bundled in the center The end of the cable may be terminated if required using the correct terminating impedance The overall length shall not exceed 1 m d LISN at least 80 cm from nearest part of EUT chassis e For the actual test configuration please refer to the related Item EUT Test Photos NOTE a Reading in which marked as Peak QP or AVG means measurements by using are Quasi Peak or Average Mode with Detector BW 9 kHz 6 dB Bandwidth b All readings are Peak Mode value unless otherwise stated QP or AVG in column of Note If the Peak or QP Mode Measured value compliance with the QP Limits and lower than AVG Limits the EUT shall be deemed to meet both QP amp AVG Limits and then only Peak or QP Mode was measured but AVG Mode didn t perform 4 1 4 DEVIATION FROM TEST STANDARD No deviation 4 1 5 TEST SETUP Vertical Reference Ground Plane 40 cm EUT Test Receiver 80 cm os Report No NEI FCCE 1 1404241 Page 13 of 27 Neutron Engineering Inc 4 1 6 EUT OPERATING CONDITIONS The EUT used during radiated and or conducted emission measurement was designed to exercise a manner similar to a typical use The sequence used is 1 Read write from to mass storage device 2 Send Receive data to from remote system 3 Send Receive audio to from audio devices 4 Repeated from 1 to 3 continuously As the mouse is a strictly input device no data is transmitted to
22. del Name ARM C2 DEP Applicant CJB Computer Job s r l Date of Test Mar 12 2014 Mar 26 2014 Standard s FCC Part 15 Subpart B 2012 Class A ICES 003 Issue 5 2012 Class A CAN CSA CISPR 22 10 Class A CISPR 22 2008 Class A ANSI C63 4 2009 The above equipment has been tested and found compliance with the requirement of the relative standards by Neutron Engineering Inc EMC Laboratory The test data data evaluation and equipment configuration contained in our test report Ref No NEI FCCE 1 1403073 were obtained utilizing the test procedures test instruments test sites that has been accredited by the Authority of TAF according to the ISO 17025 quality assessment standard and technical standard s Report No NEI FCCE 1 1403073 Page 5 of 27 Neutron Engineering Inc 2 SUMMARY OF TEST RESULTS Test procedures according to the technical standards Sandal Subpart B 2012 PASS ICES 003 Issue 5 2012 Radiated emission Below 1 GHz pass CAN CSA CISPR 22 10 H A PASS NTEU CISPR 22 2008 Radiated emission Above 1 GHz 2 NOTE 1 denotes test is not applicable in this Test Report 2 If the EUT s max operating frequency does not exceed 108 MHz the test will be performed Report No NEI FCCE 1 1403073 Page 6 of 27 Neutron Engineering Inc 2 1 TEST FACILITY The test facilities used to collect the test data in this report Conducted emission Test C03 VCCI RN C 4461
23. e Version NB 03A Schwarzbeck BBHA9120D 9120D 546 Aug 21 2014 Remark N A denotes No Model Name No Serial No or No Calibration specified Report No NEI FCCE 1 1404241 Page 18 of 27 Neutron Engineering Inc 4 2 3 TEST PROCEDURE a The EUT was placed on the top of a rotating table 0 8 meters above the ground at a 3m or 10 meter open area test site The table was rotated 360 degrees to determine the position of the highest radiation The height of the equipment or of the substitution antenna shall be 0 8 the height of the test antenna shall vary between 1 m to 4 m Both horizontal and vertical polarizations of the antenna are set to make the measurement c The initial step in collecting radiated emission data is a spectrum analyzer peak detector mode pre scanning the measurement frequency range Significant peaks are then marked and then Quasi Peak detector mode re measured d If the Peak Mode measured value compliance with and lower than Quasi Peak Mode Limit the EUT shall be deemed to meet QP Limits and then no additional QP Mode measurement performed e For the actual test configuration please refer to the related Item EUT Test Photos NOTE Below 1 GHz a Reading in which marked as QP or Peak means measurements by using are Quasi Peak Mode with Detector BW 120 kHz b All readings are Peak unless otherwise stated QP in column of Note Peak denotes that the Peak reading compliance with the QP
24. ed Item EUT Test Photos NOTE a Reading in which marked as Peak QP or AVG means measurements by using are Quasi Peak or Average Mode with Detector BW 9 kHz 6 dB Bandwidth b All readings are Peak Mode value unless otherwise stated QP or AVG in column of Note If the Peak or QP Mode Measured value compliance with the QP Limits and lower than AVG Limits the EUT shall be deemed to meet both QP amp AVG Limits and then only Peak or QP Mode was measured but AVG Mode didn t perform 4 1 4 DEVIATION FROM TEST STANDARD No deviation 4 1 5 TEST SETUP Vertical Reference Ground Plane 40 cm EUT Test Receiver 80 cm os Report No NEI FCCE 1 1403073 Page 13 of 27 Neutron Engineering Inc 4 1 6 EUT OPERATING CONDITIONS The EUT exercise program used during radiated and or conducted emission measurement was designed to exercise the various system components in a manner similar to a typical use The program contained on a PC hard disk and is auto starting on power up Once loaded the program sequentially exercises each system component in turn The sequence used Is 1 Send Receive data to from remote system 2 Send Receive audio to from audio devices 3 Repeated from 1 to 2 continuously As the mouse is a strictly input device no data is transmitted to from it during test It is however continuously scanned for data input activity Report No NEI FCCE 1 1403073 Page 14 of 27 Neutron Engineering Inc
25. espectively Mode 1 FULL SYSTEM Conducted emission test Mode 1 FULL SYSTEM Radiated emission test Mode 1 FULL SYSTEM Report No NEI FCCE 1 1403073 Page 9 of 27 C 1 RJ 45 Cable C 2 Power Cable C 3 USB Cable C 4 Audio Cable 2 C 5 Audio Cable C 6 RS232 Cable C 7 DATA Cable 4 Report No NEI FCCE 1 1403073 E 5 FLASH E 6 SD CARD 7 MICRO SD E 8 Adapter Page 10 of 27 3 4 DESCRIPTION OF SUPPORT UNITS The EUT has been tested as an independent unit together with other necessary accessories or support units The following support units or accessories were used to form a representative test configuration during the tests MotherBoard ARM C2 DEP VER NA CN 44751 SB ONOBRRCT E Du NNNM MK MERE DELL HVOAT 95NY781 Micro SD SanDisk 8 ADAPTER TG 6001 24V 0503024837 mE hid Ti 1 The support equipment was authorized by Declaration of Conformity DOC Report No NEI FCCE 1 1403073 Page 11 of 27 4 EMC EMISSION TEST 4 1 CONDUCTED EMISSION TEST 4 1 1 LIMITS FREQUENCY RANGE 150 KHZ 30MHZ FREQUENCY Class A dBuV Class dBuV 1 The tighter limit applies at the band edges 2 The limit of marked band means the limitation decreases linearly with the logarithm of the frequency in the range 3 The
26. evice operates or tunes MHz Below 1 705 Range MHz 1 705 108 1000 108 500 2000 500 1000 9000 harmonic of the highest frequency or Above 1000 40 GHz whichever is lower Report No NEI FCCE 1 1403073 Page 17 of 27 4 2 2 MEASUREMENT INSTRUMENTS LIST Below 1 GHz Kind of Equipment Type No Calibrated until Log Bicon Antenna Schwarzbeck VULB 9160 3176 Jun 13 2014 Pre Amplifier MH648A 09961 02 2014 Test Cable TIMES LMR 400 Jun 02 2014 Test Cable TIMES LMR 400 OS01 1 Jun 02 2014 EMI Measuring 6 Spectrum Analyzer Analyzer ADVANTEST Spectrum Analyzer ADVANTEST R3162 140100131 Sep 24 2014 Chance Most Most CMTB45 1 5 N A EZ ee Software Version NB 02A Above 1 GHz Kind of Equipment Type No Calibrated until NE Antenna 1G UT 91200 9120D 325 Jun 15 2014 Pre_Amplifier Agilent 84498 3008 01714 Apr 16 2014 HARBOUR B Microflex Cable INDUSTRIES 27478 LL142 May 13 2014 Microflex Microflex Cable AS 5104 5 1 1 10M May 15 2014 HE Microflex Cable INDUSTRIES 2 478 LL142 T 13 May 13 2014 6 Spectrum Analyzer R amp S FSP 40 100129 Jun 20 2014 Measurement EZ EMC Remark N A denotes No Model Name No Serial No or No Calibration specified Report No NEI FCCE 1 1403073 Page 18 of 27 Neutron Engineering Inc 4 2 3 TE
27. ff Yarig Authorized Signatory Neutron Engineering Inc B1 No 37 Lane 365 YangGuang St NeiHu District 114 Taipei Taiwan TEL 886 2 2657 3299 FAX 886 2 2657 3331 Report No NEI FCCE 1 1404241 Page 1 of 27 Neutron Engineering Inc Declaration Neutron represents to the client that testing is done in accordance with standard procedures as applicable and that test instruments used has been calibrated with the standards traceable to National Measurement Laboratory NML of R O C or National Institute of Standards and Technology NIST of U S A Neutron s reports apply only to the specific samples tested under conditions It is manufacture s responsibility to ensure that additional production units of this model are manufactured with the identical electrical and mechanical components Neutron shall have no liability for any declarations inferences or generalizations drawn by the client or others from Neutron issued reports Neutron s reports must not be used by the client to claim product endorsement by the authorities or any agency of the Government This report is the confidential property of the client As a mutual protection to the clients the public and Neutron self extracts from the test report shall not be reproduced except in full with Neutron s authorized written approval Neutron s laboratory quality assurance procedures are in compliance with the ISO Guide 17025 requirements and accredited by the conf
28. imit 79 00 79 00 73 00 73 00 73 00 73 00 Over dB 24 51 31 13 36 31 41 81 40 85 31 93 Detector peak peak peak peak peak peak Comment Limit AVG 30 000 16 27 Neutron Engineering Inc 4 2 RADIATED EMISSION TEST 4 2 1 LIMITS Below 1 GHz FREQUENCY MHz dBuV m dBuV m NOTE 1 The limit for radiated test was performed according to as following FCC Part 15 Subpart B 2013 ICES 003 Issue 5 2012 CAN CSA CISPR 22 10 CISPR 22 2008 2 The tighter limit applies at the band edges 3 Emission level dBuV m 20log Emission level uV m 4 The test result calculated as following Measurement Value Reading Level Correct Factor Correct Factor Antenna Factor Cable Loss Amplifier Gain if use Margin Level Measurement Value Limit Value Above 1 GHz FREQUENCY Class A dBuV m at 3m Class A dBuV m at 10m MHz PEAK AVERAGE PEAK AVERAGE Above 1000 80 60 695 495 FREQUENCY Class B dBuV m at 3m MHz PEAK AVERAGE Above 1000 NOTE 1 The limit for radiated test was performed according to as following FCC Part 15 Subpart B 2013 ICES 003 Issue 5 2012 2 The tighter limit applies at the band edges 3 Emission level dBuV m 20log Emission level uV m 3m Emission level 10m Emission level 20log 10m 3m 4 The test result calculated as following Measurement Value Reading Level
29. ormity assessment authorities listed in this test report Limitation For the use of the authority s logo is limited unless the Test Standard s Scope s Item s mentioned in this test report is are included in the conformity assessment authorities acceptance respective Report No NEI FCCE 1 1404241 Page 2 of 27 1 Neutron Engineering Inc Table of Contents REPORT ISSUED HISTORY 1 VERIFICATION 2 SUMMARY OF TEST RESULTS 2 1 TEST FACILITY 2 2 MEASUREMENT UNCERTAINTY 3 GENERAL INFORMATION 3 1 GENERAL DESCRIPTION OF EUT 3 2 DESCRIPTION OF TEST MODES Page O 3 3 BLOCK DIAGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED 10 3 4 DESCRIPTION OF SUPPORT UNITS 4 EMISSION TEST 4 1 CONDUCTED EMISSION TEST 4 1 1 LIMITS 4 1 2 MEASUREMENT INSTRUMENTS LIST 4 1 3 TEST PROCEDURE 4 1 4 DEVIATION FROM TEST STANDARD 4 1 5 TEST SETUP 4 1 6 EUT OPERATING CONDITIONS 4 1 7 TEST RESULTS 4 2 RADIATED EMISSION TEST 4 2 1 LIMITS 4 2 2 MEASUREMENT INSTRUMENTS LIST 4 2 3 TEST PROCEDURE 4 2 4 DEVIATION FROM TEST STANDARD 4 2 5 TEST SETUP 4 2 6 EUT OPERATING CONDITIONS 4 2 7 TEST RESULTS BELOW 1 GHZ 4 2 8 TEST RESULTS ABOVE 1 GHZ 5 EUT TEST PHOTO Report No NEI FCCE 1 1404241 Page 3 of 27 1 Neutron Engineering Inc REPORT ISSUED HISTORY Issued Date NEI FCCE 1 1404241 Original Issue May 05 2014 Report No NEI FCCE 1 1404241 Page 4 of 27 Neutron Engineering Inc 1 VERIFICATI
30. ort Limitation For the use of the authority s logo is limited unless the Test Standard s Scope s Item s mentioned in this test report is are included in the conformity assessment authorities acceptance respective Report No NEI FCCE 1 1403073 Page 2 of 27 1 Neutron Engineering Inc Table of Contents REPORT ISSUED HISTORY 1 VERIFICATION 2 SUMMARY OF TEST RESULTS 2 1 TEST FACILITY 2 2 MEASUREMENT UNCERTAINTY 3 GENERAL INFORMATION 3 1 GENERAL DESCRIPTION OF EUT 3 2 DESCRIPTION OF TEST MODES Page O 3 3 BLOCK DIAGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED 10 3 4 DESCRIPTION OF SUPPORT UNITS 4 EMISSION TEST 4 1 CONDUCTED EMISSION TEST 4 1 1 LIMITS 4 1 2 MEASUREMENT INSTRUMENTS LIST 4 1 3 TEST PROCEDURE 4 1 4 DEVIATION FROM TEST STANDARD 4 1 5 TEST SETUP 4 1 6 EUT OPERATING CONDITIONS 4 1 7 TEST RESULTS 4 2 RADIATED EMISSION TEST 4 2 1 LIMITS 4 2 2 MEASUREMENT INSTRUMENTS LIST 4 2 3 TEST PROCEDURE 4 2 4 DEVIATION FROM TEST STANDARD 4 2 5 TEST SETUP 4 2 6 EUT OPERATING CONDITIONS 4 2 7 TEST RESULTS BELOW 1 GHZ 4 2 8 TEST RESULTS ABOVE 1 GHZ 5 EUT TEST PHOTO Report No NEI FCCE 1 1403073 Page 3 of 27 1 Neutron Engineering Inc REPORT ISSUED HISTORY Issued Date NEI FCCE 1 1403073 Original Issue Mar 27 2014 Report No NEI FCCE 1 1403073 Page 4 of 27 Neutron Engineering Inc 1 VERIFICATION Equipment MotherBoard Brand Name N A Mo
31. rds FCC Part 15 Subpart B established by the FCC USA Equipment MotherBoard Model Name ARM C2 DEP Applicant CJB Computer Job 5 Address Via Ghislandi 24 25125 Brescia BS ITALY Standard s FCC Part 15 Subpart B 2012 ANSI C63 4 2009 ICES 003 Issue 5 2012 CISPR 22 2008 CAN CSA CISPR 22 10 Report s NEI FCCE 1 1403073 The test data data evaluation and equipment configuration contained in our test report s above was were obtained utilizing the test procedures test instruments test sites that has been accredited by the Authority of TAF according to the ISO 17025 quality assessment standard and technical standard s The test data contained in the referenced test report relate only to the EUT sample and item s tested Authorizeq Signatory Neutron Engineering Inc 2 lt B1 No 37 Lane 365 YangGuang St SR NeiHu District 114 Taipei Taiwan TEL 886 2 2657 3299 tuam FAX 886 2 2657 3331 Neutron Engineering Inc FCC Test Report Issued Date 05 2014 Project No 1404241 Equipment CPU MAINBOARD WITH ARM PROCESSOR Model Name ARM C2 FULL Applicant C J B Computer Job Srl Address Via Ghislandi 24 25125 BRESCIA ITALY Tested by Neutron Engineering Inc EMC Laboratory Date of Receipt Apr 18 2014 Date of Test Apr 18 2014 Apr 30 2014 n Testing Engineer LON IV 0 Technical Manager 14 Je
32. test result calculated as following Measurement Value Reading Level Correct Factor Correct Factor Insertion Loss Cable Loss Attenuator Factor if use Margin Level Measurement Value Limit Value 4 1 2 MEASUREMENT INSTRUMENTS LIST Kind of Equipment Type Calibrated until TWO LINE Test TestCable TIMES CFD300 NL co Jun 16 2014 B Test Receiver R amp S ESCI 100080 Apr 01 2014 Measurement EZ Software Version NB 03A Remark N A denotes No Model Name No Serial No or No Calibration specified Report No NEI FCCE 1 1403073 Page 12 of 27 Neutron Engineering Inc 4 1 3 TEST PROCEDURE a The EUT was placed 0 8 meters from the horizontal ground plane with EUT being connected to the power mains through a line impedance stabilization network LISN All other support equipments powered from additional LISN s The LISN provide 50 Ohm 50uH of coupling impedance for the measuring instrument b Interconnecting cables that hang closer than 40 cm to the ground plane shall be folded back and forth in the center forming a bundle 30 to 40 cm long c cables that are not connected to a peripheral shall be bundled in the center The end of the cable may be terminated if required using the correct terminating impedance The overall length shall not exceed 1 m d LISN at least 80 cm from nearest part of EUT chassis e For the actual test configuration please refer to the relat
33. tor Comment peak peak peak peak peak peak 6000 00 MHz Page 24 of 27 Neutron Engineering Inc 5 EUT TEST PHOTO Conducted emission test photos FULL SYSTEM Report No NEI FCCE 1 1404241 Page 25 of 27 Neutron Engineering Inc Radiated emission below 1 GHz test photos FULL SYSTEM Report No NEI FCCE 1 1404241 Page 26 of 27 Neutron Engineering Inc Radiated emission above 1 GHz test photos FULL SYSTEM Report No NEI FCCE 1 1404241 Page 27 of 27 Neutron Engineering Inc ATTACHMENT PHOTOGRAPHS OF EUT Project No 1404241 Page 1 of 3 Testy 88 1 gt gt EE ET 59 99 1 29 ges vvv vno TESEN ORGAN f Project No 1404241 Page 2 of 3 1 Neutron Engineering Inc Project No 1404241 Page 3 of 3 Neutron Engineering Inc FCC Test Report Issued Date Mar 27 2014 Project No 1403073 Equipment MotherBoard Model Name ARM C2 DEP Applicant CJB Computer Job s r l Address Via Ghislandi 24 25125 Brescia BS ITALY Tested by Neutron Engineering Inc EMC Laboratory Date of Receipt Mar 12 2014 Date of Test Mar 12 2014 Mar 26 2014 Testing engineer Technical Manager 14 Jeff Yarig Authorized Signatory Neutron Engineering Inc 1
34. ts by using are Average Mode with instrument setting in RBW 1 MHz VBW 10 Hz b All readings are Peak Mode value unless otherwise stated AVG in column of Note If the Peak Mode Measured value compliance with the Peak Limits and lower than AVG Limits the EUT shall be deemed to meet both Peak amp AVG Limits and then only Peak Mode was measured but AVG Mode didn t perform Report No NEI FCCE 1 1403073 Page 19 of 27 destin A 2 Neutron Engineering Inc 4 2 4 DEVIATION FROM TEST STANDARD No deviation 4 2 5 TEST SETUP Below 1 GHz Stand alone device Ground Plane Test Above 1 GHz Stand alone device Spectrum Analyzer Amp 4 2 6 EUT OPERATING CONDITIONS The EUT tested system was configured as the statements of 4 1 6 Unless otherwise a special operating condition is specified in the follows during the testing Report No NEI FCCE 1 1403073 Page 20 of 27 425175 2 re Neutron Engineering Inc 4 2 7 TEST RESULTS BELOW 1 GHZ EUT MotherBoard Model Name ARM C2 DEP Relative Humidity Test Voltage AC 120V 60Hz 40 Am 0 0 30 000 0 127 00 224 321 00 418 00 515 00 512 00 709 00 806 00 1000 00 Reading Corect Measure No Mk Freq Level Factor ment Umit Over MHz dBuV dBuV m dB Detector Comment 1 66 1920 4198 7 38 3460 4000 5 40 peak 2 145 1300 3437 5 37 29 00 40 00 11 00 peak 3 162 1040 33 20 4 91 2829 4000 1171 peak 4