Contents
1. INS INS ING ING 8 3 Remote control Users who are able to control the module via M n7 nr System Voltage System Voltage short call Temperature Temperature The number of users up to 400 These users are able to control outputs x SN ee via short call to activate voice listening and to activate ARM DISARM mode I Service Service of the system Action of the user is free to select The actions to be done by the 1551 a module after the telephone number having been recognized might be assigned to every telephone number The following actions may be selected regarding telephone number of each user e To activate outputs OUT1 OUT2 OUT3 OUT4 optionally This function might be used to lock a vehicle s ignition to start a vehicle and for remote control of other equipment e ARM DISARM security system e Activate voice listening via external microphone MIC GSM SMS DIAL security and remote control systemwww topkodas It 9 9 Temperature control and maintenance Heating and cooling system control Temperature control with GSM phones GTalarm thermostat measure temperature through a probe that is on system cable and can drive any of outputs OUT1 OUT2 OUT3 you can program which to activate or deactivate the heating cooling system so to keep the temperature required This is the way to keep room temperature required Temperature range is 40 to 80 degrees Celsius or accordingly Fahrenheit It is possible to set a
2. via SMS messages The second via PC by connecting the module to PC via programming cable Full change of parameters is possible only via PC by connecting programming cable If possible we recommend to configure the module via PC 18 1 SIM card GTalarm module is not locked with a particular GSM network This means that a user may use SIM card of any GSM service provider with a possibility to send SMS and to call In order to control the module via a short call SIM card should be have Caller ID option Usually SIM cards have such option If your card can not identify a caller please contact GSM service provide or use another SIM card Locate SIM card into a holder Card s circuitry should look downward and card s key cut angle should look upwards The card holder is of Push Push type This means that after pushing the card once it is fixed and after pushing it again it is released Locate SIM card into a holder AN Note do not locate SIM card with force because you may damage SIM card holder 2 Gently push it 3 Fix SIM card 18 2 Configuration and control of GSM communication module via SMS messages Only basic parameters of the module shown in the table 18 1 may be configured via SMS messages All parameters of the module may be changed via USB by using configuration software SERA Configuration of the module via SMS messages may be performed only with installer s password 18 1 The table shows configuration a
3. 17 Remote control of the module via SMS messages or via short call With the help of SMS messages it is possible to control devices connected to outputs Outl Out2 Out3 Out4 It is possible to ARM DISARM the security system Control command for user USER are available in the table No 18 2 The amount of users when controlling via SMS is unlimited Example of control command when changes the states of all three outputs and inquiry is made to send information via SMS about output states after changing of output states USER123456 51 52 500 123456 user code space character 51 changing of the first output state space character 52 changing of the second output state space character 53 changing of the third output state space character 80 information request command see table 18 1 space character 5 to send information via SMS about output states More examples of controlling via SMS message see the chapter Configuration of GSM communication module via SMS modules All outputs may be controlled via short call the module will automatically reject the call Up to 400 users may control the module All users optionally may control outputs Outl Out2 Out3 OUT4 ARM DISARM the security system and activate voice listening MIC It is possible to assign to each user that he is able to control This is comfortable to use a single module for controlling of few gates when several masters are 18 Preparation to
4. alarm INST123456_71_5 5 Temperature value for freezing equipment control INST 123456 72 28 5 Temperature value for heating equipment control INST 123456 73 21 7 More information about SMS commands see chapter 178 2 9 3 Connection of temperature sensor Zll Fla EEEE gt jn a eo PF Ir ho It IN IN 1S keeb EEB EBEE EEEk ISSTSISSSISSSSSISISISISISTS TO 92 Plastic Package LM335Z V Ve ADJ a LM335 BOTTOM VIEW DS005698 8 Bottom View Order Number LM335Z or LM335AZ See NS Package Number Z03A 10 ARM DISARM of the module The module can work in ARM mode and DISARM mode ARM DISARM state of the module may be changed thus via short call via SMS message via Dalass Maxim iButton and by using Lock Unlock inputs All modes of ARM DISARM may supplement each other For example The module may be activated via Touch input and deactivated via short call or SMS message 10 1 ARM DISARM via short call It is possible for 400 users to activate deactivate the module via short call The module will recognize user s number and will automatically cancel the call Not recognized numbers are being ignored Information on how to program the user numbers is available in the description of SERA 10 2 ARM DISARM by sending SMS message It is possible to ARM DISARM of the module by sending SMS message and using USER or INST password Example of SMS message e Disarm the system USER 12
5. Eua Inputs Out Onti SiM card READY Signal level fis PITT TLL Registration Registered home network SMS Service Centre Address o OBSS99992 14 gt Temperature Controller i Testing and Diagnostic Out4d Onit System State ARM M Touch Input System voltage 13 16 i ar53 ADC hss ARMDISARM System Temperature 13 3 ae ar ag ADC _ARMDISARM System Low Temp Aarm High Temp Alarm Swich on testing Switch off testing COMS is closed a COMS i opened 4 at Cie COMa Connected GTALARM w1 111026 Z 19 Software updating Updating of firmware version should be performed via PC The following is necessary e mini USB configuration cable e configuration software SERA e the new software version which may downloaded at www topkodas It More about software updating process see user manual of the software SERA Annexes 1 Annex GSM SMS DIAL security and remote control systemwww topkodas It 29
6. Low Temperature 20 0 Low Temp Alarm SMS Hanm Low Temperature OF Te jour Low Temp Alarm 2 D E Low Temperature Alarm SMS Text Low Temp Alarm Enable Temperature sensor is connected to the system wire contacts 9 Temp and 19 Temp Alarm and restore temperature may be changed Upon temperature alarm the module will send SMS message to a user And if setting exist the module will switch the selected output It is comfortable to use this function for indoor heating management In a case of accuracy shortage temperature sensor may be calibrated additionally Following the equation Temperature X ADC Y and by selecting X and Y coefficients Temperature calibration may be performed in software SERA in testing window It is necessary to have accurate thermometer in order to measure temperature at least in two points In testing window to read temperature ADC indications in these points Following the equation Temperature X ADC Y to calculate X and Y coefficients Calculated X and Y coefficients should be programmed in the module It is easy to calculate X and Y coefficients in MC Excel by using trendline y 0 3284x 269 26 Heating Hysteresis Temperature Sensor Calibration 0 3466 w 274 5 vr Equation Temperatures A 400 Teperature Temperature may be measured in Celsius and Fahrenheit GSM SMS DIAL security and remote control systemwww topkodas lt 10 9 1 Premisses automation temp
7. Optional output type FLASH feature may be used for direction indicators on arming or disarming or in the event of alarm Optional output type Sending of periodical test including system parameters SMS about state of each sensor alarms power supply voltage and GSM communication level Built in GSM module Testing and diagnostic of the module via USB by using program SERA Remote set up via SMS messages Configuration of the module via USB Free configuration program SERA Very compact Content b AS By Pe CU Rie US seeen a EE EE EEE E EE OEE O EE E 4 2 EDP ATONE EUe V O eere ene E E EE E E REE E O E 4 3J Ubcddenmitons and TrM eaaa teeter EE E T EE EE EE 4 4 Short description of the operation principle cc ccccccccssssssssseeeeecceeeeeeeeeesaaesssseeseeeeeeeeeeeeeeeeeaaeaeeeeseeeeeeeeeeeeeeeeaaas 5 Big eA Se OMB ING sree cates se Seepace pe sees oa eceacuonecs ca vecae scene E E E aaaiees 6 IL Standard Packa CONE ON ensia E E bance sscoaiesh anaes 6 D2 Additional accessories under Treguesi irisscan iian E A a N EA aA Ea iaaa 6 TE o E SS DE E EOT E A E PA A E E OAT I A E E AT 7 7 General view of the product and layout of Control devices ccceccecccccccccccccseseeeeeeseeeecceeeeeeeesesaaaaseuseeseeeeeeeeeeeeeeeaaas 8 TE Input output connector pinouts meaning and layout seeeeeeessssssssssssssetterrersssssssssssssetrrrrressssssssssseseeereeee 9 8 MS E A N A E IEE E Sede sit AI A seine asus ve sele
8. 24 hours from 00 am to 99 00 no test In the example test to users will be send each hour p 14 30 15 55 Periodical test time format HH mm Input IN1 IN2 IN3 IN4 IN5 IN6 IN7 IN8 IN9 modes unz aa JENIN See O delay 1 interior 2 instant 3 24h 4 silent 5 fire GSM SMS DIAL security and remote control systemwww topkodas It 19 109 111112214 02011114 Input IN1 IN2 IN3 IN4 IN5 IN6 IN7 IN8 IN9 types 0 NO type 1 NC type 2 EOL Service messages Arm Disarm Reset Test 1 ON 0 OFF In the example service messages Reset and Test will be sent Input triggering IN1 IN2 IN3 IN4 IN5 IN6 IN7 IN8 IN9 1 on 0 off In the event of example IN6 IN8 IN9 alarm will be activated Input restores IN1 IN2 IN3 IN4 IN5 IN6 IN7 IN8 1 ON 0 OFF In the example inputs INI IN3 IN5 IN6 IN8 IN9 will be restored Ct se IN1 input name changing up to 16 symbols the end symbol IN2 input name changing up to 16 symbols the end symbol IN7 input name changing up to 16 symbols the end symbol IN8 input name changing up to 16 symbols the end symbol IN9 temperature alarm name changing up to 16 symbols the end symbol A eC IN4 input restore name changing up to 16 symbols the end symbol IN9 temperature restore name changing up to 16 symbols the end symbol Ct Outl output activation text changing up to 16 symbols the end symbol Out2 output acti
9. OD el AU trace ei atest ocausseesiednanet E E E 18 ols MIN O ecco totems enact ana ce tte oz setae E E E secede 19 18 2 Configuration and control of GSM communication module via SMS messages cccccceeeeeceeeeeeeseseeeees 19 153 Conhisuravion of the module yid PC serieren ari E E E EOE aiai 25 18 4 Installation of the product and connection diagram eeeessssssssseseeseeeeeessssssssssssesetrereressssssssssssseereereessssss 26 18 5 Mounting instruction and connection diagram of security system for premises cccccceceeeeeeeeeeeeeeeeeeees 26 18 6 Premisses automation temperature controller installation and connection diagram ssssssesrssssssssseeee 27 Lice eS el Aa MATOS ICS erroei on a a Eaa E aN 29 D e a a E N E N E A A 29 S S ENE AOE A T E EEE E A A O T A A E E A A 29 PEE RITE E AEE E A E I E T E E E A E A A E O 29 GSM SMS DIAL security and remote control systemwww topkodas lt 3 1 Safety requirements Before applying the module in operation please read this user s guide Any operations related with mounting of the module and connecting of peripheral devices should be performed only after unplugging the module from the mains 2 Application of the device GSM communication module GTalarm hereinafter the Module is applied for transferring of GSM SMS messages to the mobile phone of a user The module GTalarm may be applied for protection of house garages cottages vehicles as well as
10. kal Es clallallelclelslelslelelee lS A olala Z1Z Z1Z1Z Z Z E Z SSSSESSSSSSSSSSSSS Z p 3 5 a gt ii COM Lo ARM State awa Aa External Pra power supply Flash Lamp _ BUZZER i 5 3 Z Z H 2 A A gt 12V Z 8 eae Ol Ol vla Ols BELL a 2 a at aE a 2 D B D no Pr DL 2 gt 12V aa x aa S mole Hols aa 5 S 7 a N XS3 COM GND i Led Gr 1 O nee RS 12y COM COM COM COM COM Soom l sad Tamper1 Tamper2 Tamper3 iButton Probe Optional O O O O O O COM NC NC NC GSM remote control 124 The module configuration blank sample for this diagram you will find after installing configuration program SERA located in the directory ConfigTemplates File name GTalarm_ v1 House_Office_Alarm tcfg 18 6 Premisses automation temperature controller installation and connection diagram Preparation of the module for operation by using configuration software pictures and the more detailed info are available in SERA description e Parameters of the selected output are set Output state SMS text output operation description OUT definition CTRL SMS DIAL state type State mode Steady If necessary output operation might be inverted e Inthe GSM communication window parameters of the users to send SMS and DIAL should be set Also check boxes should be checked to send SMS and DIAL to a user about temperature alarms e In GSM remote control window tel
11. message via short call DIAL Maxim Dallas iButton key iButton DSI990A 64 Bit ID Automatic periodical test Test sending in a form of SMS message Periodicity for communication control messages tests from 1 to 99 nights and days according to selected time Power supply voltage Nominal power supply voltage 12 6 V Power supply voltage range 9 16 V Consumption current In standy 08 0 eee Re nee ee eT oe oer re ene Cen et at ee ene nee een ner err tee eer t eee eet eee less than 50 mA In dialling or SMS sending mode 00eeeeeees less than 300 mA Environmental parameters Storage temperature range from 40 to 85 C 40 iki 185 F Operational temperature range from 30 to 75 C from 22 to 167 F Max relative humidity under 40 C 104 F wu cccccceseeeeseeeeseeees 95 GSM SMS DIAL security and remote control systemwww topkodas It 7 PACA Woie Mi repr n S EN tes one teen eaateneuenonesencieeetees 150g Mod le were Ni sepicnsceccsdadareocnsdcnqsatsteamerescsansed erei AEE 80g Overall dimensions of the module cece eee ee cecceccecescecceccscescescecescescesceces 84x60x32 mm Current consumption in idle running depends on inputs connection type on output state and load 7 General view of the product and layout of control devices SIM card holder of Push Push type GSM antenna connector RESET button MiniUSB programming connector MOD red LED see 7 1 table WDG GPS green LED s
12. use standard 6 8 wires cable for designed for installation of security system For sound signalling we recommend to use siren DC12V up to 1500mA It is recommended to connect the siren to the system by using 2x0 75 sq mm double insulation cable It is possible to supply the security system from stabilized power supply source 10 15V and not less than 1 5A It is necessary to calculate max current of power supply The current of the alarm system is the current used by sensors relays siren and other devices It is most convenient to use power supply source applied for power supply of security systems with the option to connect backup lead battery It is recommended to mount remote control relays into sockets Sockets may be easily fixed in metal box It is necessary to select relays according to preferred voltage and current Auxiliary BUZZER is recommended to be installed inside the premises not far from the entrance Buzzer operates together with the main siren also when the system starts calculating the time to leave the premises and the time till alarm response of the security system after entering the premises see clause 7 1 It is possible to use buzzer of Hitpoint PB12N23P12Q or similar modified piezoelectric 12V DC 150mA max Buzzer GSM SMS DIAL security and remote control systemwww topkodas It 26 Antenna i Reset Mini USB SIM Card MICROPHONE AC 110 220V gt N UYYY gt Temperature Sensor af A GA A
13. used to powering the module Attention AC equipment can not be connected directly to the module It is necessary to use a special relays or other methods which are in compliance with electrical safety requirements Attention When controlling devices from the AC network it is necessary to follow all electrical safety requirements Module connection scheme to control heating or cooling equipment Furnance Heater Cooling Device Air Conditioner Z fg Po a E x i lt e ry A jN oa ce ae 7 ie l SSR Output 5 Ry D an a A gt 5 x cs iv e e O a z E Z ama 7 GD os HANYOUNG Q seur i Po GD A 5 Bar a z AC 85 260V rw ny A GND DC 85 260V 5 24V Input 5 24V Input DC 10 14V gt 1A HN FUSE 5A bower Coetral DOLT GSM SMS DIAL security and remote control systemwww topkodas It 11 9 2 Remote temperature control via SMS messages Temperature may be changed in remote manner by using SMS commands Overheating temperature value upon reaching which the following SMS message will be sent High temperature alarm INST 123456 70_35 5 INST user type installer 123456 user code space character 70 the command to change overheating temperature alarm value space character 35 5 overheating alarm temperature value The end symbol Freezing temperature value upon reaching which the following SMS message will be sent Low temperature
14. 00 ooooo0000000 ooooo0000000 ooooo0000000 oooo00000000 oooooo000000 oooooo000000 g oooooo000000 ooooo0000000 oooooo000000 oooooo000000 000000000000 14 ooooo0000000 ooooo0000000 oooooo000000 oooooo000000 oooooo000000 oooooo000000 oooooo000000 ooooooo000000 ooooo0000000 11 1 iButton keys entering deletion directly into configuration program table In the configuration program to open Remote Control USERS table And to enter Button codes for users Upon entering desirable codes it is necessary to write the configuration into the module OY Dn ei wolne 11 2 iButton keys entering deletion via SMS messages Association of keys is carried out by activating special programming mode by sending SMS or by pressing Learn iButtons configuration program Format of SMS message is as follows INST123456 63 1 You will receive a message into your mobile phone in relation to activation of iButton key programming mode Touch the key to the reader and its unique code will recorded into system memory Buzzer will notify you about successful recording by beeping twice The system allows to associate up to 400 iButton keys For example You may link either one or 400 keys Each time when touching the key the system records its code till all desirable keys will be recorded If during 2 minutes not a single iButton key will not be learned the system will automatically exit keys learning mode or after
15. 1800 1900 MHz Sending of SMS messages Receiving of calls and dialling Outputs OUTI max current V 1500 mA OUT2 max current V 1500 mA OUT3 max current V 1500 mA OUT4 max current V 1500 mA All outputs can be controlled via short call DIAL or via SMS message This feature may be used for gate opening ignition locking etc Output alarm parameters may be programmed Programmable algorithms for outputs operation CTRL SMS DIAL SIREN BUZER ARM state Zones OK Light Flash inverting pulse mode INI IN7 inputs SMS text for input alarm and restore Programmable enabling or disabling of inputs Input type NC NO EOL Algorithm for zones operation delay interior instant 24 hours silent fire Response time Time of additional response Commutation of selected out put INS voltage control internal power supply voltage input Alarm voltage programmable Restore voltage programmable Programming based voltage calibration Power supply voltage range from 8 0 V to 16 V Measurement scale 0 01V IN9 temperature control parameters External temperature sensor Alarm temperature programmable Restore temperature programmable Programming based calibration of temperature sensor Temperature measurement range from 40 C to 80 C Measurement system Fahrenheit Celsius Measurement scale 0 1 C 0 18 F Module control ARM DISARM of the security system via Touch input 5 control algorithms via SMS
16. 3456 59 0 e Arm the system USER 123456 59 1 GSM SMS DIAL security and remote control systemwww topkodas It 12 More info see 8 2 10 3 ARM DISARM by using Touch input A few ARM DISARM modes of the security system are available e Ist mode gt 500ms Positive Pulse On Touch input If in input Touch gt 500ms the impulse will appear into V the security system s state will be changed from ARM to DISARM or wise versa e 2nd mode gt 500ms Negative Pulse On Touch input algorithm similar as 1 mode only inverted e 3rd mode Positive Level ARM Negative Level DISARM On Touch input When in input Touch is a positive level V the state of the module will be ARM When negative level V the state of the module will be DISARM e 4th mode Positive Level DISARM Negative Level ARM On Touch input as the 3rd mode is only inverted e 5th mode iButton Access ID On Touch Input uses Touch input System state ARM DISARM is changed by using Dalass Maxim iButton key Button DS1990A 64 Bit ID see Fig GTCO 14 ARM state LED K 2 Y DS1990A Serial Number iButton iButton Probe V A r 7 Touch a ip L 18 4 COM aati Fig GTCO V A ol Touch ARM DISARM input ARM DISARM switch Fig 10 1 10 4 Automatic arming of the security s
17. EI IMEI number of GSM modem HW hardware version SW software version System state request according to the command USER123456 80 7 GSM SMS DIAL security and remote control systemwww topkodas lt 24 123456 user code space character 80 command see table 18 1 space character e 7 command system state request The module will sent two part message to the number the SMS was sent from Below you will see the example of received SMS message following request command USER123456 80 7 The first of two SMS System voltage State ARM Clarification system state Inputs In0 Door closed Clarification state of the first input In1 PIR1 OK Clarification state of the second input In2 PIR2 OK Clarification state of the third input In3 MicrowaveRestore Clarification state of the forth input In4 Shock restore Clarification state of the filth input The second of two SMS Inputs In5 Ignition OFF Clarification state of the sixth input In6 Siren OFF Clarification state of the seventh input In7 Battery restore Clarification state of the eighth input In8 Temp restore Clarification state of the ninth input Output states Outl OFF Clarification state of the first controlled output Out2 OFF Clarification state of the second controlled output Out3 OFF Clarification state of the third controlled output The module is considered to be installed properly and communicati
18. Exit Delay are applied for this zone Such type zones are used for connection of door sensor o Interior disturbance of this type of the zone will not be responded if alarm of Delay type zone occurred and Entry Dlay or Exit Delay time still have not run out Such type zones may be used for connection of motion sensor in front of the door The input will be activated immediately if the door has not been opened before o Instant Instant zone Upon disturbance of this zone the system will immediately activate burglary alarm o 24 hours Upon disturbance of this zone the system will activate burglary alarm not depending whether the security system is in ARM or in DISARM modes The applications of this type zones are safes storehouses tampers of the sensors o Silent silent zone is always active not depending on whether the security system is ARM or DISARM Upon disturbance of this zone SMS messages are being generated but the siren will not be activated These zones may be applied for voltage temperature control AC mains failure control and for alarm of silent panic o Fire this zone is always active not depending on whether the security system is ARM or DISARM The zone generates a special siren signal with interruptions The zone is applied for smoke sensors and for fire alarm e Enabling or disabling of zone alarm or restore e Input speed time of the input reaction this is the time period during which chan
19. NO EOL SSS ARM DISARM state LED anode Negative supply voltage GND 8 Users 8 1 Control and programming of the module via SMS messages 8 1 1 Installer Installer is able to execute all INST commands available in the table S The installer is able to change parameters of the module only with INST password 8 1 2 User User is able to execute only user s USER commands available in the table S 2 A user may send SMS request any time and receive parameters of the security system zones and inputs states communication strength temperature etc SMS messages may be used to control outputs Outl Out2 Out3 Out4 and to activate ARM DISARM mode A User is able to control the module only when using USER password USER 1 Communication Settings x Please note that all phone 8 2 Users to receive SMS DIAL messages OEE piae Rap L PEA country code area The number of users up to 16 These users are able to receive DEEE R 1 For example messages or and calls after alarm response of the security system or Aei communication test or system state test messages which are being generated after alarm response of the security system or following test messages 5049 SMS AlarmRestore p Dialing to USER Alarm Restare M oM IT M schedule The number of users up to 16 See Error Reference source not M N2 Select Al in2 Select All ound on how to define types of messages to be sent to different users Bis clear at E earan
20. Topkodas UAB Topkodas GSM SMS DIAL security and remote control system User s guide Prog Version GTalarm v1 APPLICATION Individual protection of houses garages cottages and other premises For remote monitoring of premises and for control via GSM network Remote control of the devices via GSM network Access control Gate door control Automation of premises temperature and voltage control GSM thermostat for premisses and heating systems Remote voice listening FEATURES GSM SMS DIAL security and remote control systemwww topkodas It 7 inputs Fully programmable zones 1 inputs for arm disarm the security system 4 programmable 1 5 OC outputs for remote control or for fulfilment of selected function 1 output for monitoring of system s state LED indicator 16 users who receive information about protected object Reception of information in a form of SMS or via DIAL short call 400 users Activation deactivation ARM DISARM and output control by using Maxim Dallas iButton keys iButton DS1990A 64 Bit ID 400 users being able to control gate or electromagnetic lock via free short call ARM DISARM of the system via free short call Temperature measurement For temperature control tracking alarm and control Voltage measurement Voltage monitoring and alarm External microphone Remote voice listening option via external microphone Option to connect BELL for sound siren alarm System state BUZZER
21. be kept attached for 15 sec white keys learning mode will be activated Buzzer beeps ARM state indicator starts blinking 500 500ms Further another keeps you need to learn should be touched After 120 sec the module will automatically exits the keys learning mode The same applies to keys deletion mode Keep MASTER key attached for 30 sec ARM state indicator starts blinking 250 250ms After the same procedure applies to all other keys you want to delete After 120 sec the module will automatically exits keys learning mode GSM SMS DIAL security and remote control systemwww topkodas It 14 12 Module inputs zones GTalarm module has e 7 programmable external inputs zones e temperature sensor input e Measuring of power supply voltage Internal input is visible in programming table e Control input Touch see section 0 3 Each input may be linked with selected output i e to switch selected output depending on output state This feature enables to apply the module for premisses automation and temperature control For example For example if temperature drops below the standard limit the module is able to automatically activate heating system and also to inform a user about critical temperature by sending him an SMS 12 1 Equivalent input diagrams Equivalent 1 7 input diagram P GTCO INI I 12 2 Sensor connection diagrams Sensors may be connected fo
22. cicccccscessccensdeesievedeecasecdecencvdueaceasdeeetevsd bidebecasienedseusceues teabedebescatucdedenceiat 16 123 Microphone and vOICe Ms emi S xc 22coveciercccscetsceauddeessevedeesntecveteacpseezceusddeeetavad nade aiaa ai aai i aa airi 16 I MPO Cr aA SOUL DUIS soinn S 16 13 1 Equivalent output diagrams iis icccsacveiieswetedtenconetiuccaieiieateiets ocvetedtohivowtsacseieiboncetelvenienbedbakdunciiesdeieataatelaivadeielieys 16 13 2 Output connection diagrams ssesssssseeeeeeeeeeessssssssssseseeterrrrsssssssssssssrerrrrrsesssssssssssesetereressssssssseseeeererresessss 16 13 3 Operational output parameters sosssssseeoeoeeeeeesssssssssseseetterrersssssssssssssettereresssssssssssseeteereressssssssssssesereeeresessss I7 14 Timers of the security system nenesssssssseeeeeeererssssssssssssseetrrrersssssssssssseeereeresssssssssssseseteereesssssssssssseeeeeerresesssssseess I7 14 1 Setting of built in clock module nnnnennnnnnnnnnnssnsssssssssseeeeererssssssssssssssererersssssssssssssseeeereresssssssssssseetereeresessss I7 15 Automatic periodical test sending 000oooooeeeeeeesssssssssseseeterrerssssssssssssscerrrrressssssssssssssttrerereossssssseseeeererereesssssssseees 17 TGs VTC SS SSS SC T ea oestrus antes orn net eeneses E aan eto nerd me EA A E AE 18 17 Remote control of the module via SMS messages or via Short Call 0 0 0 ccccccccssssssssssseeeeceeeeeeeeeeesaasaeeesssseeeeeeeeees 18 TSG Hee Pa ALO UO
23. e following SMS message will be 70 30 0 35 54 A sent High temperature alarm Freezing temperature value upon reaching which the following SMS message will be 71 2 0 10 3 4 sent Low temperature alarm Send via SMS a part of information regarding configurations of the module 1 05 12 command code parameters will be sent 21 28 command code parameters will be sent 31 38 command code parameters will be sent none 1 40 49 command code parameters will be sent to make a request about output states Out 1 Out 4 test request system state request input output states will be sent along with current state of the system ARM DISARM O To D 123456 654321 To change installer s INST code recommended to change before applying the module in operation GSM SMS DIAL security and remote control systemwww topkodas lt 20 Remote module reset Reset by using SMS message Time format of the module dd MM yyyy HH mm dd day of the month 1 31 93 none 31 12 2010 23 55 MME moN Aske yyyy year HH hours 0 23 mm minutes 0 59 Examples of typical programming messages 1 Programming of users telephone numbers to send SMS and to make a call INST123456 01 37011111111 01 123456 installer s code space character 0l command code programming of users numbers space character user s telephone number without comprised of country code operator s code and user s telephone numbe
24. e security system USER123456 59 1 ARM the security system It is possible to receive test of the module on the basis if request command USER123456 80 6 123456 user code space character 80 information request command see table 18 1 space character 6 command test request 1 enable OUTI output 1 OUT1 2 OUT2 3 OUT3 4 OUT4 48 Output triggering time limit set for 48 seconds After time limit of 48 seconds OUT1 will be disabled Upon sending command SMS USER123456 80 6 test message will be sent to the number from which SMS message has been sent Below see the example of received test SMS message Clarifications Signal strength Numerical values of communication signal level Corresponds the following meanings according GSM telephone 0 very weak signal communication loss limit 1 5 very weak signal correspond to one bar on the monitor of a mobile phone 6 9 satisfied signal correspond to two bars on the monitor of a mobile phone 10 14 good signal correspond to three bars on the monitor of a mobile phone 15 and more excellent signal corresponds to four bars on the monitor of a mobile Test Signal strength 17 System voltage 13 16V Temperature 26 1 C IMEI 356895030001799 HW GTalarm SW GTALARMv1 100801 Voltage Voltage of car battery or other power supply source the module is connected to Temperature temperature sensor s showings C or F IM
25. ee7 1 table REG yellow LED see7 1 table Power supply and input output connector External microphone connector tS a a a E 7 1 Meaning of LEDs Name Indication variations Meaning eae Flashes remains lit for GSM module is in ARM security mode External indicator 50ms turns off for ARM state 15 300ms contact Blinking remains lit for GSM module is in DISARM non security mode 50ms turns off for 10s Blinking remains lit for The module is functioning WDG green built in 50ms turns off after LED 1000ms The module is out of order or no voltage Lights continuously Modem has been registered to the network Flashes remains lit for Modem is being registered to the GSM network 50ms turns off for 300ms Off Modem failed to register to the network Flashes Power supply OK and the module is registered to the GSM network MOD red built in Lights continuously Modem power supply is OK but the module failed to register to LED the GSM network Modem power supply failure or it is switched off REG yellow built in LED GSM SMS DIAL security and remote control systemwww topkodas It 8 7 1 Input output connector pinouts meaning and layout V E 1 GND_ Negative supply voltage GND Z gt Z o o 4 Input2 2zones input NC NO EOL S 5 Input3 3 zones input NC NO EOL SS 6 Input4 4zones input NC NO EOL S 8 Input6 6 zones input NC NO EOL SSS 9 Input7 7 zones input NC
26. eeeeeeeeeeeeaaaeseeenees 12 10 3 ARM DISARM by using Touch input cccccccccccccccccccecceeeeeseeseseseeeeeeeceeeeeeeaaaeeeseseseeeeeeeeeeeeeeeeasaeageennes 13 10 4 Automatic arming of the security system Auto rearm ou ccccccccccccceceeeeceeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeess 13 10 5 Bell confirmation signal by arming disarming the Security SYSteM cccccccccsssssssseseseeeeceeeeeeeeeeeeaaaeeseeeees 13 Me WUE Ny eE A E eoebacienisopoeedstel doasiausdomtanen E 14 11 1 iButton keys entering deletion directly into configuration program table cccccssseeeeeeeeeeeeeeeeeaeaeeeeeeees 14 11 2 iButton keys entering deletion via SMS messages cccccccccssssssssssseeeecccceeeeeeeeeeaeeeseecseeeeeeceeeeeeseeeeaaaaaeeesses 14 11 3 iButton keys learning by using MASTER Key 0 00 ccccccccsssssesesseeeeceeeeeeeeeeeesaaaeeeesseeeeeeeeeeeeeeeeseaaaeaeesnees 14 2 Module inputs ZO S et ecaed te actenrg pte tcseatnasiectoptcenuinsstniciee cates aa ins tuiive pe aeuaiga desiauiedlstaneniciuieauiatyoubaeunsa dedaianed ethene vlodcianinaytawenaaten 15 l2 Fo ivalnt imputi dia Tams 2 susota as tce endi n E aE aa aE 15 De o or COMMCC MOM a E a a sncesatenseeureccaueniecadapbsesueau dens tamil sense ber ee meu tuacnlangeeineaute 15 12 3 ENpUt COMMPUTALION PALaMClelS sassserceveckenccescetsceeudsesssevednesntecvereacpseezceasddzeeavad nade aiaia and aiiai diia aain 15 12 4 Voltage measuring INS Gmternal a sccvc
27. ephone numbers of users who will be able to control selected outputs via free short call should be entered GSM SMS DIAL security and remote control systemwww topkodas It 27 In Inputs windows input parameters should be set After pressing temperature sensor line IN9 at the bottom of the window temperature parameters options will be shown Alarm and restore temperatures should be set Input eeen Alem esre Tirat Type Te Det ee Beien Restore a Restore Restore Restore Restore Restore Restore al Hatery restore Temp restore IHS IH4 IHS IHG IH ln Temperature parameter Alarm temperature fi 5 IE Restore ee s si RIE OOOO OO lt lt Td NC NC NC NC NC NC NC NC Aditional Calibration x 0 3329 y 270 37 Temperatures ADCT silent silent Silent silent Silent silent Silent silent silent 00m O00ms O00ms O00ms O00ms O00ms 00m 6S000ms O00ms Disable 60s Disable 60s Disable 60s Disable 60s Disable 60s Disable 60s Disable 6000s l e If necessary automatic output management depending on the temperature should be set At the end of IN9 line select which output will be controlled It is also necessary to check check boxes Alarm and Restore e And to set Input speed and Repeat time times In order to control big power alternating current equipment it is comfortable to use solid state relays Standard AC DC adapter with the vo
28. erature controller installation and connection diagram Preparation of the module for operation by using configuration software pictures and the more detailed info are available in SERA description e Define parameters of the outputs Output state SMS text output operation description OUT definition CTRL SMS DIAL state type State mode Steady If necessary output operation might be inverted e Inthe GSM communication window parameters of the users to send SMS and DIAL should be set Also check boxes should be checked to send SMS and DIAL to a user about temperature alarms e InGSM remote control window telephone numbers of users who will be able to control selected outputs via free short call should be entered e On The Temperature Controller Settings window set the cooler device temperature control settings o Cooling temperature value High temperature Cooling hysteresis Select cooler control output OUT1 OUT4 or disable if cooler device is not used Determine the temperature value at which will be sent an SMS overheat temperature alarm Determine the temperature at which the value will be sent an SMS temperature alarm o Ifyou want to receive overheat alarm need to check box Enable e Similar settings are done with heater control options O O Oe In order to control big power alternating current equipment it is comfortable to use solid state relays Standard AC DC adapter with the voltage 10V 14V and current gt 1A might be
29. finishing programming of the keys you might send SMS message INST123456 63 0 This SMS will disable recording of new keys into memory In the event of failure to send this message ARM DISARM of the system via iButton key will not operate Control functions for all newly associated keys will be assigned according to MASTER key For example If MASTER key will control OUT1 all newly associated keys will also control OUT1 In order to delete all iButton keys from the memory e g if it was lost or if it was stolen please send SMS INST123456 63 3 All key codes available in the system memory will be deleted Association again will be carried out as described early 0 0 OO gaga 0 OOO Oy 3 oO Oo Oy Oo oo Oo Oo na a a agaga agaga aaaaaoqa aaa OOO OOOO 0 OOo OO oOo Oo oy ooo 0 0 OO 0 3 OO OO 3 oO OO 3 oo Oo ag 7 0 OO 0 7 3 OO 3 3 Oy 3 3 2 4 3 Oo kK 7 0 0 OOO OO Oo OO OO aaga gaa agona _ co In order to delete iButton key from the memory it is necessary to have that key which you want to delete from the memory and to send SMS message INST123456 63 2 After sending that SMS message the module will delete these keys which will be touched to the reader 2 minutes later the module will deactivate the keys deletion mode 11 3 iButton keys learning by using MASTER key The mode for new keys learning may be activated by using MASTER key Master key should
30. for access control gate control objects automation smart house and temperature control For premisses protection and many other applications In the event of burglary the device depending on programmed operation algorithm is able to call or to send SMS to up to 16 users A user is able to hear what is going on premises after answering a call or he may make a call by himself A user is able to receive an SMS with detailed information about status of each protected zone and number of alarm events The user is able to control the device via SMS messages only if he knows user s password If a call is being performed from the telephone number not included in the system s data base the call is rejected immediately The module has system voltage control If power supply voltage drops below the defined value a user automatically will be notified via SMS The SMS message includes voltage of backup battery System Voltage The module has external temperature sensor A user receives information about temperature alarms and restores via SMS messages The SMS on voltage of the module and ambient temperature is also available Temperature may be measured in Celsius and Fahrenheit SMS periodical test ensures communication control of the module Test sending time is programmable Test Time The test will include all essential information GSM communication strength system car battery s power supply voltage temperature and IMEI of the module Remote Cont
31. ged input state should remain stable in order to let the module to register alarm or restore input state e Repeat time this is the time period during which repeated event of the input will be ignored e Zone action switching of selected output OUTI OUT2 OUT3 OUT4 in the event of alarm or restore May be used for object automation For example for indoor temperature control Upon dropping of temperature will critical limit heater would be switched on automatically 12 4 Voltage measuring IN8 internal This input is visible only in configuration window of the SERA software of the module IN8 input is intended for power supply voltage control A user will always be alerted that a car battery has been charged or discharged This the car battery will be protected from full discharge or damage Alarm and restore voltages are programmable Voltage measurement may be calibrated additionally 12 5 Microphone and voice listening Microphone should be connected to the external microphone connector 10 see 7 In order to avoid noises the microphone should be mounted as far as possible from GSM antenna 400 users are allowed activating voice listening in the objects In order to allow a user to activate voice listening it is necessary in user table GSM remote control to check the box MIC 13 Programmable outputs The module GTalarm has 4 programmable outputs Outputs of the module may be used to switch relay LEDs siren or
32. h are the more convenient for him 58 command changes the state of selected output for set time limit If you wish to change invert OUT1 OUT4 states and to receive information about output states the following message should be sent USER123456 50 150 3 805 123456 user code space character 50 to change state of selected output space character 1 to change state of first output OUT 1 space character 50 to change state of selected output space character 3 to change state of third output OUT3 space character 80 5 command to send SMS about output states This command is not necessary Possible commands Clarifications If you wish to activate OUT1 and to deactivate OUT2 USER123456 51 1520805 123456 user code space character 51 set OUT 1 state space character GSM SMS DIAL security and remote control systemwww topkodas It 23 e 1 deactivated output e space character e 52 set OUT2 state e space character e 0 deactivated output e space character e 805 command to send SMS about output states This command is not necessary Output control by selecting trigerring time interval USER123456 58 1 48 enable OUT 1 for 48 seconds USER 123456 58 2 5 enable OUT2 for 5 seconds 123456 user code space character 58 command see table 18 1 space character automatically e ARM DISARM of the security system via SMS message USER123456 59 0 DISARM th
33. h way to ensure GSM communication It is necessary to properly select place for GSM antenna GSM antenna can not be hidden deeply in metal constructions to prevent GSM communication screening GSM antenna should be mounted as fa as possible from electronic sensors shock microwave microphone temperature sensors etc because GSM electromagnetic field may disturb operation of sensors or other electronic devices We are not liable for disturbances related with your GSM communication service provider Connection diagram is available in the annex however other connections versions are also possible Fuses are necessary In order to check operation of the module it is necessary to activate used sensors door PIR sensor etc and to observe their operation The user should receive messages a about alarmed zones depending on programming If SMS messages have not been received please check GSM communication and whether the module is configured properly by sending 80 command with 1 2 3 4 5 6 7 parameters We recommend to check configurations of the module and test with the software SERA The module is considered to be equipped properly and communications is reliable if all sent SMS and calls are properly received as well as all user commands are being performed 18 5 Mounting instruction and connection diagram of security system for premises It is recommended to use standard motion fire glass breaking sensors For powering of sensors we recommend to
34. ion ARM DISARM is selected 4 Delete user s for remote control via short call telephone number according to ID number or all numbers at once INST123456 61 001 Delete user s telephone number whose ID number is 001 It is possible to select from 001 to 400 INST 123456 62 Delete all numbers of remote control users from 001 to 400 5 Inputs programming INST123456 11 00000111 12 01101111 80 1 123456 installer s code space character 11 command see table 18 1 space character 00000111 used inputs are calculated from the left to the right IN IN2 IN3 IN4 IN5 alarms are disabled and IN6 IN7 IN8 alarms are enabled e space character e 12 command see table 18 1 GSM SMS DIAL security and remote control systemwww topkodas It 21 space character 01101111 IN1 IN4 restores are disabled IN2 IN3 IN5 IN6 IN7 IN8 restores are enabled space character 80 command see table 18 1 space character 1 will send command code 05 12 parameters back to SMS sender More input parameters may be changed via USB 6 Programming of input names INST123456 21 Alarmluggage 22 Alarmcapote 23 Alarmdoor 80 2 Output names programming INST 123456 40 37011111111 01 43 ignition off 80 4 123456 installer s code space character 40 command see table 18 1 space character ignition on name of output state when ignition is on 43 command see table 18 1 space character ign
35. ition off name of output state when ignition is off space character 80 command see table 18 1 space character 4 will send 40 49 parameters of command codes 7 Programming of output parameters INST123456 48 1010 49 1053 80 4 48 command outputs inversion see table 18 1 space character 1010 OUT 1 inverted OUT2 normal OUT3 inverted OUT4 normal space character 49 command description of operation output algorithm see table 18 1 space character 1053 OUTI siren OUT2 remote control OUT3 light signalling device FLASH OUT4 ARM State space character 80 command see table 18 1 space character 4 will send 40 49 parameters of command codes 8 Module control modes ARM DISARM see chapter see 0 3 ARM DISARM by using Touch input chapter INST123456 05 1 123456 installer s code space character 05 command see table 18 1 space character 1 ARM DISARM mode see chapter see 0 3 ARM DISARM by using Touch input chapter GSM SMS DIAL security and remote control systemwww topkodas It 22 18 2Table of users codes Command Beginn arameters 8 Password P ing default settings 1 OUT1 2 OUT2 3 OUT3 4 OUT4 Change state of selected 50 none 1 2 3 4 OUT output Output state changes every time after sending command code Explanation see below the table 1 2 3 4 1 2 3 4 selectable output number 58 ane ia delimiter Time in seconds Time de
36. limiter ARM DISARM command 0 DISARM the security system 1 59 none Oor 1 i ARM the security system Send via SMS a part of information regarding configurations of the USER 123456 module 01 12 command code parameters will be sent 21 28 command code parameters will be sent 31 38 command code parameters will be sent ce eee 40 49 command code parameters will be sent to make a request about output states Out 1 Out 4 test request System state request will send information on input output states and system state ARM DISARM Time format of the module dd MM yyyy HH mm dd day of the month 1 31 93 none ome month 1 12 yyyy year HH hours 0 23 mm minutes 0 59 Outputs control via SMS messages Output states of the module may also be controlled via SMS messages Let s assume that vehicle ignition should be blocked thus the first output should be connected to ignition blocking relay For outputs control the following commands are used 50 51 52 53 54 58 Command 50 changes inverts state of selected output When this command is being sent output state is being changed 1 e if output has been deactivated it is activated and vice versa 51 52 53 54 commands sets preferred output state if O is being sent the output is being deactivated if 1 the output is being activated 50 and 51 52 53 54 commands performs the same action i e changes output states The user may use command whic
37. llowing 4 different connection diagrams e NC normally closed contact e NO normally open contact e NC EOL normally closed with end of line resistor line resistor e NO EOL normally closed with end of line resistor resistor NOTE All resistors should be 1 kOm 10 The length of wires for connection of sensors can not exceed 300m and resistance of wire connected to sensor contacts can not exceed 300 Ohms Resistors should be mounted as near the sensor as possible Improper connection of resistors system will not work properly 3 IN1 IN7 5 IN1 IN7 A IN1 IN7 3 IN1 IN7 Ano IKO O NO EOL Anc IK 0 NC OL COM COM COM COM 12 3 Input configuration parameters INPUT 3 Settings l x ame tetotion NG T Zone Type Door opened Alarm SMS Text Door closed Restore SMS Text Zone Options W Alarm Enabled Zone Speed 200ms ms J Restore Enabled Event Repeat Timeout 602 Z Zone Action The following parameters may be set for all inputs GSM SMS DIAL security and remote control systemwww topkodas lt 15 e Text of SMS messages for alarms and restores This text will be included when sending SMS message to a user about alarms and restores of zones e Input types NC NO EOL These parameters should be set depending on type of zone connection e Definitions of input application o Delay Entry Exit zone Set Entry delay and
38. low temperature alarm and a high temperature alarm Passage through these thresholds will trigger alarm SMSs You can choose a temperature hysteresis If the temperature is too low or too high the Module will send SMS message including warning and actual temperature value allowing you to take action or a output to be activated to correct the temperature For example a user can receive a reporting SMS and also switch output on or off to achieve the requested temperate This is quite powerful temperature control system not only for residential use but for professional use only If your company sells heating on a calories basis this solution can help you a lot avoiding energy waste and useless trips to a location If you have a house in the mountains and want to make sure temperature is kept correctly GT auto is a professional solution to implement this decision Module can be used to monitor industrial refrigerators electrical transformers animal farms or any location or machine where temperature control is significant Temperature controller configuration window Temperature Controller Settings odling Settings High Temperature 26 0 ne High Temp Alarm SMS Alarm High Temperature ee z L La EF D h cooling Hysteresis 0r ge High Temp E Cooler Output jourt Cooler OFF High Temp Alarm 300 0 Lif High Temperature Alarm SMS Text High Temp Alarm Enable ee Hester OFF eating Settings Low Temp n _ Heater Ob
39. ltage 1OV 14V and current gt 1A might be used to powering the module Attention AC equipment can not be connected directly to the module It is necessary to use a special relays or other methods which are in compliance with electrical safety requirements Attention When controlling devices from the AC network it is necessary to follow all electrical safety requirements Module connection scheme to control heating or cooling equipment ieee Device a M AC 85 260V DC 85 260V SN t gaat ad oras AeH N pA ea i g S 2 bp y O UN NAA SIM Card oli a a A N aleile 5 Bee i AIR mooo Antenna WIS ICO IN ZIZIZIZ 4 4 4 4 jm i _ 2 zh TIT SISISISISTSISISISISISIISTSTS GSM SMS DIAL security and remote control systemwww topkodas It Reset Mini USB a DC 10 14V SPA ooo O V FUSE 5A V 12V AC DC adapter 10 14V gt 1A 28 18 7 Testing and diagnostics Diagnostics and testing of the module may be performed via USB port with software SERA The software will show system input output GSM states in real time Thus it would be easier to evaluate whether the module operates as appropriate SERA GTALARM configuration E ioj x File Setup Devices Update About aal ej n System Options H GSM Communications USERS amp Remote Control ti Onf 259772030854955 Eois Outputs
40. med the system turns into ARM state along with beep sound to confirm the action o ARM state state of alarm system ARM DISARM May be used for light indication o Inputs OK if any of zones is disturbed the output will be alarmed This feature is usually used for indication whether all zones are in order o Light Flash used for connection of light signal Upon alarm of the security system the light starts blinking Lights will also blink when arming disarming the security system e Output inversion e Output type is constantly on off or impulse e Output impulse duration 1 65535 seconds 14 Timers of the security system Entry Delay time period during which the user after passing Delay zone should manage to disarm the security system Exit Delay time period during which the user should manage to leave the object and pass Delay zone Siren time Siren switch on time in the event of alarm Test time time of automatic periodical test Test Period test sending period in 24 hours 14 1 Setting of built in clock module Built in clock of the module is to be set by SMS message or by using configuration software Time setting via SMS message INST123456 93 31 12 2010 23 55 123456 Inst password space character 93 command for clock setting space character e 31 12 2010 23 55 time dd MM yyyy HH mm Time format of the module dd MM yyyy HH mm dd day of the month 1 31 MM month 1 12 yyyy year HH ho
41. n fact the module will make repetitive calls following the programmed number of calls Note Efficiency of this function depends on interpretation of call control by the operator in some cases the operator may wrongly interpret the call and thus the module will make repetitive calls each 60 seconds following the programmed number of repetitions by default 3 repetitions In such case GSM operator may be changed or simply the amount of DIAL repetitions reduced Parameters of the module are set by sending SMS or via PC by using standard miniUSB cable and configuration software SERA which is available to download at www topkodas It Page In order to activate voice listening it is necessary to call from a user s telephone number When calling the module will immediately activate voice listening which will last as long as the user will reject the call or when the module will start performing other commands Calls from other telephone numbers of non authorized users are ignored GSM SMS DIAL security and remote control systemwww topkodas It 5 5 Package content Note Some package content may be optional Please ask seller for more information 5 2 Additional accessories under request Mini USB cable Mini CD 1 pcs iButton DS1990A F5 key e User s guide in PDF e Program SERA e USB drivers GSM SMS DIAL security and remote control systemwww topkodas It 6 6 Specifications Parameters of built in GSM module Quad band 850 900
42. na NA S A A A 9 8 1 Control and programming of the module via SMS messages ccsssssssssseeeeeceeeeeeeeeeeaeaessseeeeeeeeeeeeseeeeeaaas 9 okle Tae aean E E AEE E E TEN EA E O O TEO ET O N TEE E 9 oile U Pee E T T EEA I EA TAE EE AAEE EEE TETAN A AAO RS 9 8 2 Users to receive SMS DIAL is A Sa acisstercdtenatandenstera ne yaodtandenannnnsaloascntane adeentles adawaecamcanaehancioossudossa ines daanossmenasaten 9 8 3 Remote control Users who are able to control the module via short Call cee eeesseeessseeeeeeeeeeeeeeeeeeeeeeaees 9 9 Temperature control and maintenance Heating and cooling system COMtIOL ccccceeecceeeeeeeeeeeeeaeeseeeseseeeeeeeess 10 9 1 Premisses automation temperature controller installation and connection diagram eeeesseeesseeeeeeeeeeees 11 9 2 Remote temperature control via SMS messages sssssssssseseeeeeeresssesssssssssseeereresssssssssssssseterreressssssssssseeereree 12 9 3 Connection of temperature SONS OF sesserireriosnsa en aan EAEE EENE EEEE AEN arsi 12 10 ARM DISARM ofthe module eeeeeeeeseeeessseeseesesessessssseesereeeeeeeeeeeeeeeeeeeeeeerereeseereeeeeeereeerereeeeeeeeerereeeeeeeeeeeeeeeees 12 10 1 ARM DISARM via short call c cccccccccccsccccccccccscccccccccccccccscceccccccceccccnececccccccecccccececcecccceccccnececceacecececesecences 12 10 2 ARM DISARM by sending SMS message ccccccccccccccccceeeeessesseeeecceeeeeeeeeaeeaaeeessseeeeee
43. nd control codes of the module Configuration of the module may be performed via SMS messages Configuration SMS command structure Verifier INST Install This verifier is used for configuration of parameters of the module USER User This verifier is used for module control Installer s or user s password space character Command code space character Configuration array One SMS message may include as many commands as one SMS message may cover i e 160 symbols including spaces In such case firstly verifier should be sent password should be written without space after the verifier and further come command code parameter command code parameters etc separated with space The module executes the commands as follows the first command next after the password and further go all other commands from the left to the right 18 1 T able of Installer s command codes Command Examples of command parameters default parameters Clarifications settings examples Telephone number of users to whom send SMS and to whom make a call DIAL up to w frome foa 16 symbols the end symbol after the symbol user priority number 01 16 should be entered maa Delete selected user s telephone number according to priority number User ID from 01 to 16 03 mone f Delete telephone numbers of all users cao ARM DISARM control modes 0 1 2 3 4 5 see 10 3 chapter Ca 01 Periodicity of communication test in
44. on is reliable if all messages and calls are received properly and all user command are being executed properly 18 3 Configuration of the module via PC The module may be configured and tested via PA by using standard miniUSB cable This configuration is being performed by using the software SERA which you may download at www topkodas lt More info about the module configuration by using SERA program see SERA description loxi File Setup Devices Update About jla ale B cysten Options System Settings i a GSM Alarm Security System Access Control Temperature Controller Inputs ardware details i Event SMS Text Installer Password p 6 symbols Auto reARM HA GTALARM H Custom SMS Text FETT M Siren Peep on ARMDISARM Root Temperature Controller User Password 6 symbols V Zone Auto Bypass PA GTALARM v1 111026 Testing and Diagnostic Temperature Scale celcius ARM IDIGARM hethod Button Access ID Gn Touch Input Learn Buttons Stop Learning frao Test Period f Days 0 disabled Entry Delay z Exit Delay _Set Module Clock PU ie e aA aa E Siren Time Read Module Clock Module Time 31 10 2011 13 48 50 Reset Module COMMS i closed COMS is opened bet Ces lieu kd COMMS Connected iGTALARM 1 111026 E GSM SMS DIAL security and remote control systemwww topkodas lt 25 18 4 Installation of the product and connection diagram The module should be installed in suc
45. operate Before or after installation of the module it is necessary to configure its parameters SIM card settings may be configured by using only GSM phone How to prepare the module to operate e Connect system connector GSM antenna e Connect power supply source 10 15V battery or stabilized 10 15V 1A power supply source Check and if necessary enter SMS message centre number using GSM phones Mostly SIM card already has SMS centre number inserted please skip this step Remove PIN code request of the SIM card it can be done using GSM phone Install SERA configuration program Connect USB cable to the PC and to the module Launch SERA program Guidelines on how to use SERA program is available in SERA description GSM communication strength IMEI and SMS centre number are available in Test window see SERA description Configure telephone numbers to which information should be transferred e Set the numbers to send SMS and to make a call e Set active inputs which will be used For example if the input will not be used it should be disabled GSM SMS DIAL security and remote control systemwww topkodas It 18 e Set periodicity of communication test if OO is entered the test will not be send e Set input parameters e Set output OUT1 OUT2 OUT3 OUTS states if applied After inserting SIM card or upon changing parameters of the module it is necessary to press RESET button There are two types to configure the module The first
46. other sound device Current for OUT1 OUT4 is 1500mA All outputs are protected from short circuit over voltage and overheating 13 1 Equivalent output diagrams OUT 1 OUT4 outputs is open collector in terms of grounding V OUT1 OUT4 equivalent diagram GTalarm OUT1 OUT4 COM 13 2 Output connection diagrams Examples of output connection diagrams see below GSM SMS DIAL security and remote control systemwww topkodas lt 16 GTalarm 1500mA GTalarm 1500mA OUTI1 OUT4 OUTI1 OUT4 lt amp V Siren L v L COM V COM 13 3 Operational output parameters The following parameters may be set for each output e SMS text for ON output state e SMS text for OFF output state e Output operation algorithm OUT def o CTRL SMS DIAL output is used for remote control via short call or SMS e g for ignition blocking for gate control or for remote vehicle starting etc o SIREN output used for connection of siren Siren time can be changed o BUZER sound signalling device In the event of zone alarm beeps continuously When security system starts calculating exit delay the user is able to hear short repetitive sound signals When 10 seconds are left till the begging of activation signals are being repeated each 0 5 seconds If after expiry of the delay time all zones remain unalar
47. r the end symbol e 0l user ID number 01 16 In this example the telephone number of Ist user is entered After the telephone number has been entered all events of the security system will be sent to a user Optional events to be send may be selected only when configuring via USB i 123456 948921 To change user s USER code recommended before applying the module in operation 2 Itis possible to delete telephone numbers one by one according order of priority or all 16 numbers at once INST123456 02 15 INST123456 02 15 Delete user s telephone number whose ID number is 15 It is possible to select from 01 to 16 INST123456 03 INST123456 03 Delete all 16 users telephone numbers 3 To enter user s telephone number for remote control via short call INST123456 60 3701111111 001 000100 123456 installer s code space character 60 command code programming of users telephone numbers for remote control via short call space character 3701111111 user s telephone number without comprised of country code operator s code and user s telephone number the end symbol e 00l user ID number from 001 to 400 In this example the telephone number of Ist user is entered the end symbol e 000100 What actions should be done after making call to a user Sequence from the left to the right OUT1 OUT2 O0UT3 OUT4 ARM DISARM MIC 0 active functions 1 non active function In the example the funct
48. rol by Dialling The module compares incoming number with programmed users numbers and in a case of coincide activates an output or other action and interrupts the call automatically All parameters of the module should be configured via PC by using software SERA or in remote manner by sending appropriate SMS including password 3 Used definitions and terms e Installer a person provided with INST installer s password e User is a person being aware USER password e Authorized user is a person whose mobile phone s number is entered in GSM module Two authorized users with the same rights may be entered into the module e Configuration programming of the settings which will define the operation of the item For example user s telephone numbers set up of periodicity for sending SMS message input names etc Event event a user receives the information about ARM status of the security system The module is in ARM mode DISARM status of the security system The module is in standby mode only 24h inputs are active NO input type Normal Open this means that the alarm will be send when the input will be connected with ground V NC input type Normal Close this means that the alarm will be send when the circuit between input and ground V will be broken EOL end of line resistor input type with resistor Service messages ARM DISARM test resetting of the system DIAL the system makes a call to the n
49. umber specified Pull up resistor is that it weakly pulls the voltage of the wire it is connected to towards V or whatever voltage represents a logic high MIC microphone COM negative power supply terminal V positive power supply terminal SSR Solid State Relay Caller ID Caller s identification GSM SMS DIAL security and remote control systemwww topkodas It 4 4 Short description of the operation principle The module transfers messages on events of the security system to the mobile phone of a user via GSM communication channel Upon alarm occur the module will generate SMS message about alarmed sensors Door PIR Fire etc SMS message is being sent to a user in line with a short call This is to reduce the probability that a user will not observe SMS message It is possible to send SMS and to call to 16 users The algorithm of message sending is SMS1 SMS2 SMSn till all SMS messages will be send After DIAL1 DIAL2 DIALn All messages are being sent until all users will be notified about the event Preferred messages and texts of these messages should be defined when programming the module The module understands when the call is rejected and will not repeat calling When the module is calling to the user s phone the user can not reject the call at least 15 seconds Otherwise the module will understand that the user s number is busy and will try to repeat the call again In a case the user s number is busy i
50. urs 0 23 mm minutes 0 59 After successful setting of module time the module will send confirmation SMS the clock will be set The timer may be set according to PC time via USB by using configuration software SERA In order to set module s timer time it is necessary to press Set Module Clock button 15 Automatic periodical test sending Periodical test may be used for communication control of the module It is necessary to carry out these actions GSM SMS DIAL security and remote control systemwww topkodas It 17 e To set built in clock of the module see chapter 4 e To set test sending periodicity in 24 hours e To set test sending time at which hour of the 24 hours the test will be sent Test sending may be disabled by setting test sending time 00 Periodical test may be used for SIM card s account control The following parameters of the module are available in a test message GSM communication strength power supply voltage temperature IMEI number of the module software version 16 Messages sending Messages are being sent in the event of alarm after ARM DISARM of the security system if specified in the configuration upon test sending time if specified in the configuration after changing the module configuration if specified in the configuration upon sending request about parameters command code 80 SMS about alarm of the security system is doubled with a short telephone call if specified in configuration
51. vation text changing up to 16 symbols the end symbol Out4 output activation text changing up to 16 symbols the end symbol Out output deactivation text changing up to 16 symbols the end symbol Out2 output deactivation text changing up to 16 symbols the end symbol Example outputs OUT1 OUT2 OUT3 OUT4are inverted Description of output Out1 Out2 Out3 Out4 operation algorithm In the above example OUT1 will operate in siren mode OUT2 for remote control OUT3 to connect buzzer BUZZER OUT4 Zones OK 1 OUTI1 2 OUT2 3 OUT3 4 OUT4 Change state of selected OUT output Output state changes every time after sending command code Explanation see below the table 59 none fort o ARM DISARM command 0 DISARM the security system 1 ARM the security 59 none Oor 1 system Command to enter new user for remote control via short call Command parameters none TelNo 001 000100 User telephone number end symbol user ID number from 001 to 400 dial action 0 js frome off or 1 on sequence OUT1 OUT2 OUT3 OUT4 ARM DISARM MIC Delete selected user s telephone number according to ID number User ID from 001 to 62 none __ Delete alll telephone numbers of remote control users from 001 to 400 _ _ 0 to turn off iButton keys association mode 63 1 l to associate new iButton keys 2 to delete touched iButton keys none 3 to delete all iButton keys Overheating temperature value upon reaching which th
52. ystem Auto rearm If the function Auto reARM is on the module will automatically return to ARM state if during Entry Delay none of zones was alarmed This feature is active only if the module was deactivated via telephone DIAL or SMS This protects from casual disabling of the system via telephone 10 5 Bell confirmation signal by arming disarming the security system The siren will generate confirmation signal when arming disarming the security system if function Siren signal on ARM DISARM was selected in the software SERA When the security system is to be turned in ARM mode the bell will beep once when in DISARM mode the bell will beep twice GSM SMS DIAL security and remote control systemwww topkodas It 13 11 iButton keys The First iButton key may be learned recorded by touching it to the reader Without the need to send any SMS The system will notify about successfully recording of the key into memory by shortly beeping twice via buzzer The system will automatically assigns control function ARM DISARM The first key is the main key MASTER Other keys might be learnt thus 1 To enter key codes directly into configuration programme table 2 By pressing Learn iButton button in a configuration table 3 By sending SMS with command for new keys learning 4 By using MASTER key 5 Q S User Name User Phone 21 Out3 Out4 Arm Disarm MIC Master Jon 1100658984949 AF0028758580 oooooo0000
Download Pdf Manuals
Related Search
Related Contents
CURRICULUM VITÆ cPCI_216_Basic 4U_10U_84HP_1_1 User Manual COLLE ENDUIT LIEGE/ FIBRES DE BOIS SPI 200-12SS SPI 200-24SS Owners Manual Samsung 8 kg 1 400 RPM Máquina de lavar roupa EcoBubble WF80F5E5U4W manual de utilizador Amplicom PowerTel 57 Fender 1515 User's Manual Closet Maid S16GDW10 User's Manual Philips Citrus Press 25W, 0.6L SOIN DU LINGE Professional Ariel Copyright © All rights reserved.