Home

Installation Instructions for the garage door operator

image

Contents

1. IDUL RECEIVER CARD 2 Press the hand transmit ter button you want to use The operators light stops blinking the transmitter was succesfully programmed Quick reference Programming additional hand transmit ters from a distance Remark additional hand transmitters can be programmed either like the first transmitter or from a distance as explained below 1 Open the garage door After the garage door is closed for approx 50 cm and close you have got 10 seconds to pro it again ceede to step 2 2 Press buttons 1 2 simultaneousely on any registered transmitter for 3 sec The operators begins blinking release the hand transmitters buttons 3 Take the new hand transmitter and press the button you want to use shortly The operators light stops blinking the hand transmitter was successfully programmed 18 Basics As a standard the operator is equipped with a 433 MHz AM remote control set The coding is done via rolling code the code is changed after each impulse receiver and transmitter agree com pletely automatic about the next code to be used New codes will be chosen out of a pool of billions of possible codes Your operator is equipped with our standard remote control set when you hand transmitters looks like the one shown on the right hand side The 4 channel MIDI transmitter is standard equipment the 2 channel MINI transmitter is avail
2. Installation Instructions for the garage door operator TS Solar This booklet must be handed over to the end user together with the user manual English Content Information and Remarks Directives and Regulations Use of the operators Garage Doors The installers declaration of conformity Older Garage Doors Important Information for the Installer 3 Instruction for the users Security Advises for the Installation 4 Installation Different Conditions for Installation 5 Minimum space above the garage door Door Arm Extension C Rail Extension Pre Mounting the operator 6 Installing the operator 6 Minimum head room above the door Adjusting the running length blocks 8 The Emergency Release 9 When there is a second entrance to the garage When the garage door is the only entrance The Solar Components TS Solar Mounting the Solar Panel 10 TS Solar Using the Solar Panel 11 TS Solar Power Cord 11 Printed Circuit Board Adjustments and Connections Before Usage Connecting the Battery Cable 12 Devices for Adjustments 12 TEST Button 1 LEARN Button 2 Combined TEST LERN button functions Programming Running Length and Force 13 Information 1 Adjusting the running length blocks 2 Starting the programming mode 3 Start the learning cycle Quick Reference Special Functions 14 Readjusting the time for the internal light Setting the pre warning ON OFF Programming the Soft Modes The BOTTOM Soft Sto
3. ige 8 a 3 Shortly press the b TEST button iag Solar TEST si le l 4 Shortly press the TEST button iag Solar TEST sl DP E i 5 Shortly press the red LEARN button LERN LEARN TEST RUN ARENS LERN LEARN TEST RUN n gt z MODUL RECEIVER CARD LED TEST indicates status LED on pre warning ON LED off pre warning OFF LERN LEARN TEST RUN JL RECEIVER CARD By pressing the TEST button the pre warning is switched on and off LED on pre warning ON LED off pre warning OFF LERN LEARN TEST RUN L RECEIVER CARD The chosen adjustment is saved into the memory AODUL RECEIVER CARD 14 TOP soft mode BOTTOM soft mode a Quick Reference Programming the BOTTOM Soft Mode 1 During the first learning cycle in CLOSING direction LERN LEARN TEST RUN P al 2 The operator is running in CLOSING direction with increased speed LERN LEARN TEST RUN DIP gt Zz DUL RECEIVER CARD ON Als 5 ON MODUL RECEIVER CARD Keep the LEARN button pressed during the first run in CLOSING direction and keep it pressed the operator increases speed Release the LEARN button at the position where the soft stop shall start in future If the LEARN button is kept pressed until the door is completely shut then the soft stop will be disabled 3 The operator reaches the CLOSED position It will proceed with the lear
4. 2 Durance of the internal light How to adjust these functions is explained on page 14 Special Functions Information To properly use the operator it is necessary to programme the run ning length and the force Using the operator without these important adjustments may lead to damages on the garage door and the operator For test runs without a garage door the running length blocks must be tightened please refer to page 8 Adjusting the running lenth blocks The programming procedure is done completely automatic with an automated procedure The programming mode needs to be started first it will be indicated by the blinking operators light The quick reference on this page shows a short summary of the procedure 1 Adjusting the running length blocks This step is descriped on page 8 Adjusting the running length blocks Remark the blocks are fixed by tightening the screw 2 Starting the programming mode Keep the LERN LEARN button 2 pressed for 3 seconds release it once the operators light begins blinking The operator is now running in programming mode 3 Start the learning cycle Shortly press the LERN LEARN button 2 once again The operator now starts three fully automatic measurement runs 3 1 First the block for OPENING direction is searched for 3 2 Second the operator closes the garage door with low speed during this run you may also chang
5. through the automatic force setting the requested values for forces and reversion will be according to the regulations But it needs to be taken in consideration that most older garage doors do not meet the regulations EN 12604 and EN 12605 especially regarding security features They might still have sharp edges bearing the danger of severe injuries for example sectional doors might not have a finger protection between the sections Unfortunately the entire regulations do not mention how to handle the automation of such an older garage door the danger basically is not the automation but the construction of the door Therefore we strongly recommend to check the garage door for sharp edges bearing danger when the door is moving take any necessary action to avoid the dangers and make the door safer check the doors springs and readjust them if necessary grease or oil the pivotal points and rollers of the garage door check that the door may be easily used by hand Information and Remarks Important Information for the Installer x yx x CE x Kur If however the dangers cannot be avoided we recommend to use the automatic pre warning function of the operator The opera tors lighting will then be blinking for approx 5 sec before every movement of the garage door People inside the garage will be warned before the opening and can step back from the garage door in time Instruction for the u
6. No AN 16062003 ve Dokument Nr AN 16062003 N x We Wir Seip Antriebstechnik GmbH Grombacher Stra e 83 75045 Walzbachtal J hlingen Deutschland hereby declare that the following products comply to the mentioned EC regulations erkl ren hiermit da die nachfolgenden genannten Produkte den unten angegebenen EG Richtlinien entsprechen Type of Product Produktart Garage Door Operator Torantrieb Product Name Modell TS Solar TS Akku Approved according to 89 336 EEC and 73 23 EEC Gepr ft nach 89 336 EWG und 73 23 EWG Referring EC regulations Angewandte harmonisierte Normen Electromagnetic Compatibility EN 61000 3 2 2000 Elektromagnetische Vertr glichkeit Limits for harmonic current emissions Grenzwerte f r Oberschwingstr me EN 61000 3 3 1995 Corrigendum 1997 A1 2001 Limitation of voltage changes voltage fluctuations and flicker in publik low voltage supply systems Grenzwerte f r Spannungsschwankungen und Flicker EN 61000 6 3 2001 Emission standard for residential commercial and light industrial environments St raussendung f r Wohnbereich Gesch fts und Gewerbereiche sowie Kleinbetriebe EN 61000 6 2 2001 Generic standards Immunity for industrial environments Fachgrundnorm St rfestigkeit Industriebereich Low Voltage Directive EN 60335 2 95 2001 7 Niederspannungsrichtlinie Particular requirements for drives for vertically moving garage doors for residential use Anforderungen f r Antrieb
7. TS series is compatible with HomeLink systems from Software Revision 6 or higher Older Software Revisions are not supported Information on the Software Revision in your car can be obtained from the cars documenta tions Information on how to program your HomeLink device can either be obtained from your cars documentations or from the internet site www eurohomelink com Remote Contro Additional Informatio 4 channel MIDI transmitter 433 MHz rolling code Battery Usable types of batteries A23 23A 23L EL12 VR 22 and MN 21 Voltage 12V n Used batteries must be disposed of according to national laws 2 channel MINI transmitter optional extra 433 MHz rolling code Two Batteries Two batteries type CR1616 or DL1616 are required Voltage 2 3V 6V Used batteries must be disposed of according to national laws Please avoid to drop the hand transmitter parts could be damaged inside the transmitter That might lead to malfunctions 19 Technical Information Technical Data Pre Warning Light adjustable Soft Stop in Closing Direction adjustable Net Running Length 2 640 mm ax Running Length with Extension 4 050 mm 500 mm Overall Length 3 200 mm Maximum Pulling Force Force Setting for Operation Running Speed Speed in Soft Mode Lighting Durance adjustable Recommended max running cycles per 3 Openings approx day for TS Solar I Recommended max running cycles per 6
8. distance from the ground To make the solar panel work most efficiently it should be adjus ted to the south as precisely as possible the more exact it faces south the better the output Please pay attention to the following restriction when choosing a location for fitting the solar panel the most efficient output is reached by adjusting the panel as exactly to the south as possible shades from buildings or trees should be avoided as far as possible In the shade the solar panel will not produce any electricity bare in mind that in winter the sun will pass on a lower horizon than in summer the solar panel could be shaded by a opposite building in winter Check this with the residents who will know the circumstances during the seasons best The correct angle of 60 is held by the bracket Run the cable total length 7m into the garage from the outer wall of the garage do not run it directly through the ceiling Make sure the cable rises from the outside to the inside of the garage to keep water from flowing inside ATTENTION the solar panels and cables must be connected correctly to the P C B If the connection is made the wrong way around then the battery will not be recharged 10 Screws holding the panel in the correct distance from the ground rubber bumpers The cable should rise slightly from the outside to the inside of the garage Connecting the solar panel Minus blue Plus
9. the learning cycles the DIP switch no 1 fulfills its normal function Normal Force Higher Force during CLOSING Soft Stop as to page 10 TIP should you decide to remove the jumper then plug it back onto one pin only so it remains available on the PC B for later use 13 Printed Circuit Board Adjustments and Connections External Connections LED Diag Solar TEST 412V T5 ji Ak t u nz a Gnd ee N D O I a AN lL 5 Empfanger ka i r 4 o Mm i A ollo p O O i Jo ai H 12v _ tl E E G L5 LS Test TST 12Vdc F Gnd g E9 Ls Sender 5 se FE ts _LS SE 1 7 ee l E End D End e Be Bk2 Sicherheits 7 C N End B Gnd Bt A BT Solar ze lle e J S amp 2s a S 8 Netzeingan 23aVac a 11 i m 8 1 iJ E Q R 2 r PE O PE pO i D EEE L il O Connector Function Push Button and BT Gnd Floating connector for push button and key switch no electricity to come into contact Key Switch A B with these connectors Gnd Om BT OG 12V DC Supply 12V Gnd 12V DC Poewer Supply for external security devices 150 mAmp max F H This connector only carries voltage as long as the operators light in switched on it can therefore not be used for external remote receivers uv OH HIV LS TSTIC R Gn IO Photo Cell tr
10. 83 and the other relevant provisions of the FTEG Article 3 of the R amp TTE Directive when used for its intended purpose bei bestimmungsgem er Verwendung den grundlegenden Anforderungen des 83 und den brigen einschl gigen Bestimmungen des FTEG Artikel 3 der R amp TTE entspricht 83 1 1 Article 3 1 a does not refer to this type of product 3 1 1 Artikel 3 1 a bezieht sich nicht auf diesen Produkttyp es gibt hierzu keine Norm Protection requirement concerning electromagnetic compatibility 83 1 2 Article 3 1 b Schutzanforderungen in Bezug auf die elektromagnetische Vertr glichkeit 3 1 2 Artikel 3 1 b EN 300 220 1 1997 EN 300 683 1997 EMV EMC Directive 89 336 EEC 92 31 EEC 93 68 EEC Pa Peter Seip Gesch ftsf hrer Walzbachtal J hlingen 16 06 2003 eo e ANTRIEBS P Grombacher Stra e 83 75045 Walzbachtal J hlingen Germany www seip com 23 ANTRIEBS Pra
11. NTION The TS Solar TS Akku is equipped with a fully automatic measure ment for the required running length When shipped the opera tor is programmed with a standard running length for factory testings If you want to run the operator for testing purposes you must fix the blocks inside the c rail by tightening the screws A test run may only be done after making sure that the blocks are fixed properly Otherwise damaged might apply to the operator Installing the operator Minimum head room above the door Meassure the distance between the ceiling and the highest point reached by the garage door 1 The minimum headroom necessary for mounting the operator is 35 mm If there is less headroom please pay attention to page 5 The front fixing angle can be mounted either at the lintel or at the ceiling 1 Meassure the middle of your garage door and make a mark on the lintel and the top of your door 2 2a 2 Fix the front fixing angle in the middle either at the lintel or at the ceiling We recommend the lintel if possible 2 2a Installation Installing the operator 3 Attach the C rail to the front fixing angle 3 Put a carton piece under the motor head unit to avoid damages 4 To fix the motor head to the ceiling we recommend you to use a ladder 4 When the operator is laying on the ladder you can open the garage door Adjust the C rail according to the mark you made in the middle of the gara
12. Openings approx day for TS Akku I Accumulator Lead 12V 12Ah Type Panasonic LC RA1212P Expected Accumulator Life Time 3 to 5 years approx Power Supply TS Solar I Solar Panel 38 cells 10WP 18 4V at 0 55A Power Supply TS Akku I 230 Vac Wiring re e tt es Splar IEST LERN LEARN TEST RUN cle 8 Internal Wiring Devices for adjustments 230Vac Blue mains supply 230V N Button Runs the operator OPEN STOP CLOSE Brown mains supply 230V L1 Test Run Licht Brown blue Lighting 12V Button For automatic force setting and registration Lighting Lern Learn of hand transmitters Bat 12V Plug for Battery Cables red cable Pole black cable Pole Others MOTOR Connector for the plug from the motor HF Modul Receiver Plug for receiver module 433 MHz Card Earthing from the printed circuit board to the base plate FUSE Fuse T10A Earth Cable The earthing of the mains supply green from power yellow is connected to the base plate with a cord screw SOLAR Solar Panel brown and blue TS Solar only 20 Technichal Information Messages from LED lamps and operators lighting The TS Solar TS Akku is equipped with an automatic diagnostic system which provides information via the external LED lamps These messages are Status Messages In intervalls of 10 seconds the yellow and green LED lamps give information about the battery status and if the battery is being rechared or not Yello
13. able as an optional If your operator is equipped with another remote control set please refer to the manufacturers instructions for programming Programming Transmitter and Receiver To use a hand transmitter it must first be registered programmed by the receiver Only one hand transmitter button can be used for one receiver Registering the first hand transmitter The first hand transmitter e g no hand transmitter has been registered for the receiver yet must be learned directly via the operators main electronic 1 Press the LERN LEARN button on the main electronic for approx 3 seconds until the operator s light starts blinking and release the LERN LEARN button 2 Press the hand transmitter button you want to register to the receiver the operators light stops blinking when the transmit ters signal was received The transmitter is now registered Registering additional hand transmitters When at least one hand transmitter has been registered by the receiver you may program additional hand transmitters from a distance 1 The garage door must be closed 2 Open the garage door approx 50 cm and close it again 3 After the garage door is closed you have got 10 seconds to press the buttons 1 2 simultaneously on the registered hand transmitter the operator s light then starts blinking 4 The light will keep blinking for another 10 seconds during that period of time you must press the button on the new hand t
14. an be used for quicker recharging of the battery using a 230V power supply if however 230V are available by means of an extension cable Whilst the solar panel can only recharge the battery during approx 5 hours of usable sunlight in wintertimes the recharging from a 230V source can be made 24 hours a day e g about five times quicker When using the TS Solar sensibly 2 to 3 openings a day the power cord should not be needed Attention If the battery is damaged then the operator will not work with 230V either The power cord is only supposed to recharge the battery it is not possible to run the operator directly from 230V 11 Printed Circuit Board Adjustments and Connections Before Usage Connecting the Battery Cable Before using the TS Solar TS Akku the battery needs to be connected to the P C B The red and black battery cables are equipped with a polarized plug which needs to plugged onto the electronics connector Bat 12V Information red cable Pol black cable Pol Devices for Adjustments 2 1 LERN LEARN TEST RUN OION a if This page only shows the functions of the buttons and potentiometers on the P C B To programme the operator ple ase refer to page 13 onwards TEST Button 1 With this button you put the operator into operation The button works on the OPEN STOP CLOSE principle e g the first pu
15. ansmitter Photo Cell receiver Photocell with self test Explaination the P C B offers the possibility to check the photo cells functions before the operator starts running This test is made by simulating a fault on the photo cell for 1 Second before every run ATTENTION if the self testing function shall be used then the photo cell must be connected as shown below BEFORE run ning the learning cycle otherwise the self test will not work Photo Cell transmitter Photo Cell receiver 16 Printed Circuit Board Adjustments and Connections Advanced Connections Soy e LEDs iag Solar TEST ar i i 12Vde 100 gZ ANT 1Ls ee i u N J N ET w 2 _ glo lol 3 E mza H 12V _ 5l N N a LS LS Test 6 ES T u N 3 G TST Ti2Vde A o a F Gnd AA LS Sender BE U w 5 ena Em SLZ Bk2 Ger heits 4 L T c L a Sehlupt er B Gnd ee 7 n ia g BT I is A BT Solar zelle P Ne S E VU Z 7 2x S I 2 J AUF a C Netzeingan Es _ 23aVac 0S Nu L 3 q O N a N N we N 7 PE Safety Beam Hatch Door and Emergency Stop Function with 8 2 kOhm The devices on this connector are checked during the complete opening and closing procedure When this connector is inter resistor rupted then the operator will stop immediately followed by a short reversio
16. be maintained before automation The door must be easily opened and closed by hand A garage door must not be automated unless it is easy to open and close manu ally Garage Doors In January 2001 the European regulations EN12604 and EN12605 became compulsory for garage doors Before installing an au tomatic door operator it must be assured that the garage doors applies to these regulations the information can be obtained from the manufacturers declaration of confirmity A Seip door opera tor may be installed to any door that complies to the regulations Should a garage door not be compliant then please refer to the chapter older garage doors The installers declaration of conformity No matter whether a door operator was delivered together with a garage door or seperately the installer must issue a declaration of conformity for the complete installation With this declaration the installer assures that the installation was made according to the instructions given by the manufactur ers e g the installation instructions of the garage door and the operator This declaration can only be issued by the installer and may not be issued from the manufacturer If both components comply to the directives and the installation was made as to the manufacturers instructions the whole installa tion will normally be CE compliant Older Garage Doors When automating an older garage door the TS series will still comply to the regulations
17. brown The Solar Components TS Solar Using the Solar Panel The cells on the solar panels are connected serially The total output of the panel is determined by the cell providing the lowest output This means that if only one cell is covered by snow frost leafes or shade that the complete output of the panel may be zero Dependant on the remaining batteries capacity it is recommended to quickly remove any obstacle from the solar panel If the obstacle is only to remain for a few hours then there is no need for instant action e g snowfall in the morning where the snow will be melted away in the afternoon It should be avoided that the solar panel cannot produce any out put for two or more days Though a full batteries capacitiy will last for approx 20 days without recharging please refer to chapter Technical Data max running cycles the battery will have run flat by then The operator will then switch off until the batterie is recharged Especially in winter with only little daily sunlight the recharging procedure for a flat batterie might take 3 to 6 days when being dependant on the solar panel only Whether the solar panel is producing any power for recharging the battery can be seen at the yellow LED lamp which is visible on the outside of the operators housing TS Solar Power Cord As a serial standard the TS Solar is shipped with a power cord If required the power cord c
18. cs needs to be exchanged 6 blinks No information can be written to the microprocessor The electronics disables itself and needs to be exchanged 7 blinks A relais is damaged The electronics disables itself and needs to be exchanged 8 blinks General fault The electronics disables itself and needs to be exchanged 9 blinks Error with the detection of Hall Sensor signals Either the mo tors Hall Sensor or the electronics is faulty red green yello ERROR A TA 20 CM o k EE en 1x 29 LOW 0x 0 0x o STOP we QE sec 3E n 10 s60 OF 10sec Additional Messages only from the red LED lamp 3 blinks Photo Cell either an obstacle is blocking the photo cell or the photo cell is damaged The error message will be cancelled when the error was eliminated Error on the 8k2 connector Safety Beam Hatch Door ei Fehler an der 8k2 Auswertung Schlupft r Kontaktleiste either an obstacle is blocking the Safety Beam Hatch Door or one of the devices is faulty The error message will be cancelled when the error was eliminated 21 EC Declaration of Confirmity EG Konformitatserklarung Law Volt Directive 73 23 EEC im Sinne der EG Richtlinien ee en Niederspannungsrichtlinie 73 23 EWG a it nderungen Electro Magnetical Compatibility 89 336 EEC Be ahd Smendmente k X Elektromagnetische Vertr glichkeit 89 336 EWG x mit Anderungen Document
19. e the length of the factory pre set soft stop as described on page 13 3 3 The operator stops when the garage door ist closed the measured running length is now stored in the memory 3 4 The operator opens the garage door and measures the re quired opening force 3 5 The operator closes the garage door and measures the re quired closing force 3 6 The operator stops in closing position and remains blinking for a couple of seconds Once all the measures values have saved in the memory the opera tors light stops blinking now the operator is ready for use Procede with the programming of hand transmitters on page 18 s Di r TEST a ag Solan TES J J Printed Circuit Board Adjustments and Connections Programming Running Length and Force 2 1 anlaa The running length blocks for opening and closing direction must be properly adjusted please refer to page 8 Press the LERN LEARN button for approx 3 seconds The operators light begins blinking release the LERN LEARN button 2 Start programming mode LERN LEARN TEST RUN gt z ug HE MODUL RECEIVER CARD Press the LERN LEARN button once again shortly the operator now starts three fully automatic measurement runs gt Z ug HE MODUL RECEIVER CARD The learning cycle stops after the three runs The garage door is then closed and the operators light stops blinking The pro gramming is
20. e von Garagentoren mit Senkrechtbewegung zur Verwendung im Wohnbereich EN 60335 1 1994 A1 1996 A2 2000 A11 1995 A12 1996 A13 1998 A14 1998 A15 2000 A16 2001 Safety of household and similar electrical appliances Sicherheit elektrischer Ger te f r den Hausgebrauch Safety in Use EN 12453 2000 Nutzungssicherheit Safety in use of power operated doors requirements Nutzungssicherheit kraftbet tigter Tore Anforderungen EN 12445 2000 Safety in use of power operated doors Test methods Nutzungssicherheit kraftbet tigter Tore Pr fverfahren Peter Seip Gesch ftsf hrer Walzbachtal J hlingen 24 01 2005 ANTRIEBS Pa Grombacher Stra e 83 75045 Walzbachtal J hlingen Germany www seip com 22 EC Declaration of Confirmity EG Konformitatserklarung in accordance with the Radio and Telecommunications en dem nn ke Sch on Terminal Equipment Act FTEG and Directive 1999 5 EC unikasonsendemnncniungen UNG OEFISENLINIE x y Document No FU 18102004 x Dokument Nr FU 16062003 x x We Wir Seip Antriebstechnik GmbH Grombacher Stra e 83 75045 Walzbachtal J hlingen Deutschland declare that the product erkl ren da das Produkt SKR 433 1 Code B43A023004 1 Hand Transmitter as remote control for garage door operators Handsender als Fernbedienung f r Garagentorantriebe Short Range Device Funkger t geringer Reichweite SRD complies with the essential requirements of
21. efore installing the operator you should check the garage for the conditions of installation You will need optional extras in either of the following situations If the garage door is higher than 2 250 mm you will need a c rail extension Two sizes of extensions are available 500mm and 1 000 mmm The operator may be extended by a maximum of 1 500mm the maximum height of a garage door is 4 150mm Should the minimum space between the garage door and the ceil ing be smaller than 35mm then a door arm extension is needed For an extension you can use a metal beam from any DIY market The beam should not be shorter than the door s height Installation Pre Mounting the operator During this procedure be careful not to twist the chain Therefore do not lift the parts slide them along the floor 1 The operator is laying unpacked in front of you The motor head unit is on your right hand side 2 Lay part 1 to the front 3 Fix through pushing the C profile coupling piece 2 over it all the way home 4 Slide C rail part 3 in front of part 1 5 Set part 3 in the C rail coupling piece 4 at an angle inserting it from above as shown 6 Press down part 3 to tension the chain 7 Turn around the operator and screw in the milled nuts into the C rail coupling pieces Your operator now is readily premounted for installation The chain has been pretensioned in the factory do not change the chain tension ATTE
22. ge door Fix the operator to the ceiling when you have made sure the C rail is running straight to the front Use the supplied bracket to fix the C rail to the ceiling pic 4 and 4a 5 Now fix the door arm to the garage door 6 Take care that the angle between the operator and the door arm does not exceed a max of 45 it may be lower 6 The limit blocks must be tightened before running the Operator The garage doors bolts must be removed before running the operators otherwise damages on the garage door or operator might occure For additional security our locking set can be obtained as an optional extra Installation Adjusting the running length blocks These adjustments must be made before the programming of the forces and the running length Starting the programming procedure without correctly ad justed blocks may lead to damages on the garage door and the operator Vorgehensweise 1 The operator is mounted and the door arm is fixed to the gara ge door The trolley is locked to the chain and stands somewhere between the two blocks If however trolley and chain need to be moved you may do this using the TEST RUN button 2 Release the trolley Pic 1 and manually close the garage door 3 The block for the closing direction is now right in front of the trolley Pic 2 If not the block must be moved until it touches the trolley 4 Tighten the blocks screw to keep it in place Take care not t
23. he emergency release together with a second person Stay inside the garage and close the door with the operator Let the second person open the door manually with the door keys If this works the emergency release is mounted properly Do not leave the garage and close the garage door with the operator before you have tested the emergency release When there is a second entrance to the garage You can use the supplied handle for the emergency release pic 2 Thread the emergency release cable through the handle Fix the metal clamps to the cable where the handle shall be placed Shorten the cable below the metal clamps the handle is now be ing held by the clamps In case of a power failure the user can now open the garage door by releasing the operator with the handle for the emergency release The Solar Components TS Solar Mounting the Solar Panel The standard supply of the TS Solar contains a solar panel with a fixing bracket The solar panel produces electricity by means of sunlight with which the operators battery is recharged Only use the solar panel supplied with the operator The operators electronics is optimized for the output of this panel Using an other solar panel may cause severe damage to the operators electronics Fix the solar panel to the bracket using the rubber bumpers as shown in the sketches on the right The cable must come off the upper end of the solar panel Two screws help to keep the correct
24. he soft stop can be adjusted during the first au tomatic measurement run in closing direction Please proceed as described below 1 Start the learning cycle refer to page 11 2 the operator runs in closing direction with low speed 3 press the LERN LEARN button and keep it pressed the operator is now increasing the speed 4 release the LERN LEARN button at the position where the soft stop shall begin the operator will safe this position as the beginning of the BOTTOM soft stop If the Soft Stop is to be disabled then the LEARN button must be pressed until the door is completely closed 5 the operator will reduce speed with a short delay and then reach the closing position 6 the operator will procede with the remaining measurement runs When the operators light stops blinking all measured values are saved in the memory the BOTTOM soft stop now is in the programmed position Disabling the TOP Soft Modes The TS Solar TS Akku will start the closing procedure from OPENING position with slow speed e g TOP Soft Mode Dependant on the performance of the garage door it might be necessary to disable this Soft Mode especially when the operator reverses during that period e g pressure detection Procedure for disabling the TOP Soft Mode Set DIP Switch no 1 to OFF before starting the learning cycle and leave it in that setting until the learning cycles are completed the TOP Soft Mode then is disabled After
25. is off pre warning is OFF LED TEST FUNK is glowing pre warning is ON 4 by shortly pressing the TEST RUN button the pre warning can be switched ON and OFF 5 after making your choice shortly press the LERN LEARN but ton the setting will be saved to the operators memory Printed Circuit Board Adjustments and Connections Quick Reference Time for internal light 1 Keep the red LEARN button pressed for 6 seconds pyp SIM sr a 2 Release LEARN button After 3 seconds the operators light starts blinking after 6 seconds the green LED TEST turnes on gt u DUL RECEIVER CARD LED TEST is on LE Plat ine LEDs D TEST DIP iag Solar 3 Shortly press LERN LEARN button LERN LEARN TEST RUN Aple 8 LED TEST begins blinking at 1 second intervalls Each blinking adds 10 seconds to the ta time starting from zero LERN LEARN TEST RUN mae gt Zz 4 DUL RECEIVER CARD 4 Press LEARN button shortly when required time is reached avem estan a Quick Reference Pre Warning 1 Keep the red LEARN button pressed for 6 seconds DIP zo The adjusted time will be saved in the memory gt Zz DUL RECEIVER CARD After 3 seconds the operators light starts blinking after 6 seconds the green LED TEST turnes on UL RECEIVER CARD 2 Release LEARN button LED TEST is on iag Solar TEST sds
26. l still be approx 50 meters The range might be influenced by old batteries in the hand transmitter if you should experience a problem with the range please change the batteries first The lower the batteries run the lower the range will be Building materials of the garage In a garage made of concrete and steel you might reach a lower range than in an ordinary garage build of stone The more steel was used for the walls the shorter the range of your remote con trol Remote control activity in the area Radio and television transmitters close to your garage might reduce the range Older baby phones Especially older baby phones might influence the range of the remote control severely These devices send strong signals via the houses internal power supply net These signals also intrude other devices via the wall plug as eg the operator It is extreemely unlikely that the range will drop to an unaccept able distance If however problems should occure we will like to be helpful Use with a HomeLink System The HomeLink System is becoming more and more popular in private households Most frequently it is being used in cars the HomeLink module is integrated in the car It allows the driver to activate the door operator with a push of button which is installed in his car Once pro grammed the driver does not need the hand transmitter to access the garage with his car The standard remote control supplied with the
27. n If more than one device is connected then they must be connected in series The connector can be used for the following components 1 Safety Beam Standard safety beams are equipped with an 8 2kOhm resistor The resistor on the P C B between Gnd and SLZ must therefore be removed 2 Hatch Door Contact A hatch door within the garage door can be secured with a switch when the switch is not activated e g the hatch door stands open the operator will not work 3 Emergency Stop The procedure to connect an emergency stop push button is the same as for the hatch door contact LS LS Gnd Gnd TS siz Qha siz O Hatch Door Safety Beam and Hatch Door OSE Transmitter DIP Switches DIP Switch No Function Standard setting ON Function 1 DIP Switch position before and during the learning cycle 1 TOP Soft Mode enabled disabled enabled disabled Two ref page 15 Functions Function 2 DIP Switch position after the learning cycle normal force higher force Force during the last 500mm before reaching closing limit Standard setting ON side hinged tilting or sec Side Hinged Door door tional door 5 een S SY 17 Remote Control Programming the Hand Transmitters Quick reference programming the first hand transmitter 1 Keep the LERN LEARN button pressed for approx 3 sec The operators light will start blinking LERN LEARN TEST RUN e
28. ning cycle two more runs before finishing the pro gramming The CLOSING Soft Stop will then be set as to your adjustments Quick Reference Disabling the TOP Soft Mode 1 Set DIP Switch No 1 cycle z E 2 Start the learning cycle to OFF before starting the learning LERN LEARN TEST RUN faa e ODUL RECEIVER CARD 3 Set DIP Switch No 1 back to ON when the learning cycle is completed Ban qs Printed Circuit Board Adjustments and Connections Special Functions Programming the Soft Modes The TS Solar TS Akku is shipped with factory pre set values for the Soft Modes if the learning cycle is run without any changes to the factory settings then the pre set values will be programmed automatically The BOTTOM Soft Stop The length of the BOTTOM Soft Stop may be changed during the first run of the learning cycle in closing direction Extending the BOTTOM Soft Stop is recommended if the garage door slams on closing Reducing or disabling the BOTTOM Soft Stop is recommen ded when the bottom of the garage door does not close comple tely Expecially when mechanical spring locks are installed these might not engage When the BOTTOM Soft Stop is disabled the garage door reaches the closing position with a higher speed This gives the door a higher momentum and the bottom can fall into the doors frame the locks can then engage Programming the BOTTOM Soft Mode The length of t
29. now complete 4 You may now procede with chapter Remote Control on page 18 INFORMATION When the learning cycles are made as to the procedure described on this page then the operator will be pro grammed with the standard values for the soft modes Shall the soft modes be changed or disabled then please refer to pages 14 15 The learning cycle can be repeated at any time Running a new learning cycle will overwrite the old values and substitute them with the new ones 13 Special Functions Readjusting the time for the internal light The time for the internal light may be adjusted from 10 seconds to 5 minutes The factory setting is 3 minutes To readjust the time procede as described below 1 Keep the LERN LEARN button pressed for 6 seconds Release the button once the green LED TEST FUNK turnes on 2 Shortly press the LERN LEARN button again 3 The green LED TEST FUNK now starts blinking at 1 second intervalls each blinking increases the time by 10 seconds 5 Once the required time is reached press again the LERN LEARN button shortly The value is then saved in the memory the pro gramming is finished Setting the pre warning ON OFF 1 Keep the LERN LEARN button pressed for 6 seconds Release the button once the green LED TEST FUNK turnes on 2 Shortly press the TEST RUN button 3 The green LED TEST FUNK indicates whether the pre warning is switched ON or OFF LED TEST FUNK
30. o tighten it too strongly the c rail should not be bended 5 Now the garage door needs to be opened manually The trolley will lock into the chain you have to release it once again to fully open the garage door Pic 1 6 The block for the opening direction is now right in front of the trolley Pic 3 If not the block must be moved until it touches the trolley 7 Tighten the blocks screw to keep it in place Take care not to tighten it too strongly the c rail should not be bended 8 The trolley now needs to be locked back to the chain After that the programming procedure may be started page 12 onwards Installation The Emergency Release In case of a power failure the garage door can be opened by hand Therefore the operator first needs to be released When the garage door is the only entrance It is necessary to connect the emergency release to the door s handle pic 1 otherwise the garage cannot be accessed in a power failure situation Procede as follows 1 Find out in which direction the door handle moves when open ing the door 2 Drill a hole in that side of the door handle which turns down wards 3 Thread the cable through the hole and fix it with the enclosed metal clamps Be carefull not to put a high tension on the emer gency release cable the operator then might release from the garage door during a normal opening cycle 4 Check the function of t
31. p Programming the BOTTOM Soft Mode Disabling the TOP Soft Modes External Connections 16 Push Button and Key Switch 12V DC Supply Receiver Module Advanced Connections 16 Photocell without self test Photocell with self test Safety Beam Hatch Door and Emergency Stop Opto Sensoric Components DIP Switches 17 TOP Soft Mode enabled disabled Force during the last 500mm before reaching closing limit Side Hinged Door Remote Control Programming the Hand Transmitters 18 Basics Programming Transmitter and Receiver Clearing the receivers memory Additional Information 19 Using the remote control Criterias influencing the range Use with a HomeLink System Technical Information Technical Data 20 Wiring 20 Messages from LED lamps and operators lighting 21 Status Messages Error Messages Messages from the red LED lamp and the operators lighting Additional Messages only from the red LED lamp It is within legal regulation and without restriction to use a Seip door operator with any garage door that has been ap proved for use with other certified door operators Directives and Regulations The garage door operator TS Solar TS Akku complies to the latest European directives and regulations The declaration of conformity is enclosed at the end of these instructions Use of the operators The operators were designed for the use with up and over doors tilting and canopy type and sectional doors All garage doors need to
32. rans mitter which you want to use with the operator Once the new transmitter is registered the operator s light stops blinking The procedure must be repeated for each new hand transmitter Clearing the receivers memory Keep the LERN LEARN button pressed for approx 15 sec The operators light and the red LED Diag will start blinking after 3 seconds After another 10 seconds the red LED DIAG will glow constantly You can then release the LERN LEARN button All previousely programmed hand transmitters are now cleared from the receivers memory Using the remote control To reduce the power consumption the remote receiver is being switched on and off in short intervalls when the operator is in stand by mode kept pressed for approx 3 seconds to make sure that the signal is recognized by the receiver N Therefore the hand transmitters button must be As long as the operators lighting is switched on the receiver is activated permanently During this time even shorter signals from the hand transmitter are recognizes immediately Criterias influencing the range The TS operators are equipped with a high quality remote control set as a standard Nevertheless the remote control is the part of the operator which might be influenced by circumstances in the surroundings of the garage With our standard remote control you might reach a range of more than 100 meters In areas with high disturbancies the range wil
33. sers Please instruct the users as follows Use of the hand transmitter Use of the emergency release in case of a power failure Hand over the separate User Manual to the customer Inform the user about the Security Advises in the User Manual Up and over door sectional door Information and Remarks Security Advises for the Installation Important Safety Instructions for Installation WARNING INCORRECT INSTALLATION CAN LEAD TO SEVERE INJURY Follow all Installation Instructions Read page 3 of this instruction carefully before the installation Before installing the drive remove unnecessary ropes from the existing installation Maintain the garage door according to the advises on page 3 and to the door manufacturer s manual If possible install the drive at a height of at least 2 10 m and the manual release at a height less than 1 80 m Locate the push button within sight of the door but away from moving parts and at a minimum height of 1 50 m Fix the label warning against entrapment next to the push but ton The label fixed to the manual release may not be removed After installation ensure that the mechanism is properly adjusted and that the drive reverses when the door contacts a 40 mm high object placed on the floor Minimum space above the garage door 35mm Minimum C Rail Extension Door Arm Extension Installation Different Conditions for Installation B
34. sh opens the door the second push stops the door and the third push closes the door etc The green LED lamp TEST is switched on as long as you press the TEST button and shows that the impulse was received an recognised by the electronics Attention to use the TEST button on a factory preset operator it first must be set into LEARNING Mode indicated by the operators blinking light Otherwise the operator will only run for a short distance and stop with an error message The TEST button will work properly once the operator was set up and the learning cycle was completed 12 LEARN Button 2 This button fulfills the following functions 1 Learning the forces 2 Registering learning a hand transmitter 3 Adjusting the length of the CLOSING Soft Stop 4 Starting advanced programming functions The LEARN button must be pressed for approx 3 sec the button can be released once the operator s light starts blinking Whilst the operator s light is blinking you can either register a new hand transmitter by pushing the hand transmitters button OR you may start the learning of forces by pressing the button once again Details on both procedures can be obtained from the chapters Programming Running Length and Force on page 13 and Remote Control on page 18 Combined TEST LERN button functions Through a combined use of TEST and LERN button the following special functions can be adjusted 1 Pre warning light
35. w LED Recharging of the battery 0 blinks The battery is not being recharged TS Solar I no energy from the solar panel e g at night TS Akku l no 230V power supply 1 blink The battery is being recharged TS Solar I energy is received from the solar panel TS Akku I 230V are coming from the net Green LED Status of the battery 0 blinks The battery has no sufficient voltage to run the operator the electronic disables the operator until the battery was recharged It will then automatically enable the operator 1 blink The batteries voltage is low the operator can only be used for a restricted number of runs When this state is reached the operators light will be blinking during the run 2 or 3 blinks The battery is full and provides sufficient voltage to run the operator Error Messages Error Messages are provided by the red LED lamp Diag on the electronics together with the red LED lamp on the outside of the housing With some of the messages the operators lighting will be blinking simultaneousely Messages from the red LED lamp and the operators lighting 2 blinks The limits cannot be reached though neither an obstacle was nor a damage on the hall sensor was detected There is even tually a damage on the operators mechanics the electronic disables the operator 5 blinks The microprocessor has lost its data try to execute the learning cycle If this does not work then the electroni