Home
WHITE LIGHTNINGTM WHITE LIGHTNINGTM
Contents
1. When using studio flash units you cannot leave your camera in automatic mode as its internal meter will not be able to detect the light that will be emitted by your flash units and will thus be set to an inaccurate shutter speed and aperture opening causing your picture to be overexposed Manual exposure is a camera mode which is non automatic and requires the photographer to set their own aperture and f stop for each shot This mode does not rely on the camera s internal metering system but rather requires you to take a reading with a separate flash meter to determine correct settings When using external flash units your camera should be adjusted manually BRACKETING When shooting bracketing is taking several photographs of the same scene and setup with different exposure settings both above and below the target setting indicated by the flash meter As different brands of meters vary in their readings for a correct exposure bracketing both above and below the indicated settings will ensure that you get a properly exposed picture RECOMMENDED LONG TERM USE For the X Series X800 and X1600 up to 400 full power shots per hour may be used This will increase at lower power settings and excess use will be identi fied by the unit s overheat alarm With the X3200 up to 240 full power shots per hour may be used also increasing with lower power settings Always power down then unplug your unit when not in use FREQUENTLY ASKE
2. D QUESTIONS Q What will trigger the built in slave tripper A Our built in slave tripper is sensitive to both visible and infrared flashes of light and will be triggered by conventional flash It will in fact be triggered by any light flash that it sees One flash unit in your setup will reliably fire all of the other flashes allowing wireless firing The slave cell will be tripped by an on camera conventional flash and an infrared slave as well The slave may be inadvertently tripped by flashes from other photographers in the area and or other infrared signals as well Q Can the built in slave tripper be turned off A Yes The internal slave sensor is automatically disabled when a sync cord or blank dummy plug is inserted in the sync jack With the sync cord inserted the unit will only take its cue to fire from your camera To disengage the slave tripper without connecting it to your camera you can simply insert a blank dummy plug into the sync jack A dummy plug is simply a 1 4 inch blank stereo plug and you can order these from us should you need any Q Should I be concerned about the sync voltage A Digital camera users are often concerned about the sync trigger voltage as units with high voltages can be unsafe for the camera The X Series Flash Units however use a low sync voltage under 6 volts which is safe for use with a hot shoe adaptor or PC sync connector Some flash units especially cheap or old unit
3. Nashville Tennessee 37204 Toll Free Customer Service Line 1 800 443 5542 Local 615 383 3982 Fax 615 383 0676 e mail info paulcbuff com www PAULCBUFF com
4. WHITE LIGHTNING The White Lightning X Series Operation Manual The X Series Flash Units are manufactured and directly sold by White Lightning a division of Paul C Buff Inc and includes models X800 X1600 and X3200 This manual may also be used for operation of the retired X2400 model WHITE 2725 Bransford Ave Nashville TN 37204 tT _ loll Free Customer Line 1 800 443 5542 LI G HTN H G Local 615 383 3982 Fax 615 383 0676 Thank you for purchasing an X Series Flash Unit Please call us if you need any assistance v 02 2011 Safety Precautions For your safety please note these warnings WARNING To avoid potentially lethal conditions connect this unit only to a 3 wire grounded outlet Do not operate with 2 wire extension cords or use adapters to connect to ungrounded outlets WARNING This unit contains high voltages and internal components which can store dangerous voltages even when the unit is unplugged WARNING The unit contains NO USER SERVICABLE PARTS and should not be disassembled except by a qualified technician The only parts you may replace yourself are the flashtube and the modeling lamp though caution must be taken here and the unit must be powered down while these items are replaced WARNING Before attempting to operate your flash unit securely mount the unit to a light stand WARNING Always power down your unit and unplug it from the AC power source before removing adding or adju
5. a with its PC connection When the sync cord is plugged into the sync jack the flash unit will fire This flash will indicate that the sync cord is detected and that the unit will take its cues to fire from your connected camera 6 Adjust your positioning and flashpower settings The output settings that you choose will vary based on your subject your envi ronment and your desired effects The positioning will vary as well depending on the coverage distance and intensity required The modeling lamps will help you to determine positioning as they will show you exactly where your light will hit matching the specularity of the source with any modifying acces sories With your flash unit powered ON and connected to your camera you are ready to take a meter reading of the light adjust your camera settings and begin shooting METERING When using flash units and various light modifying techniques the best way to ensure a proper exposure is to use a high quality dedicated flash meter There are several manufacturers who offer excellent meters allowing you to enter the specific settings that you ve chosen for a shot and read the amount of light present You can connect the provided sync cord directly to a hand held meter and select the cord option for the meter s fire signaling Once you have entered the appropriate film speed ISO and shutter speed into the meter you are ready to take a reading The meter s test or f
6. ange as the flashpower or turned completely OFF The lamp may be additionally set to indicate recycle going out when the unit is fired then coming back on to indicate when recycle is complete A full range of accessories are compatible with the X Series units as a quick release mechanism attaches the entire line of standard Paul C Buff Inc reflectors and modifying accessories while dual holders allow the simultaneous use of umbrellas and counter weight shafts WHAT ARRIVES WITH EACH X SERIES FLASH UNIT Our Standard User Replaceable 250 Watt Modeling Lamp e 250 Watt 4600 Lumens Quartz Edison base light bulb e 3000 hour typical life expectancy Our 14mm 5600 K Daylight Balanced Flashtube e user replaceable flashtube e 250 000 flashes typical life expectancy Our 7 inch Silver Field Reflector 80 beam spread e recessed outer lip for snapping in our honeycomb grids e pre cut umbrella hole fits standard poles up to 3 8 inch in diameter Our Standard 15 foot Power Cord Our Standard 15 foot Sync Cord 1 4 inch Stereo Plug to PC A Black Polycarbonate Shipping Cover A Set of Small Nylon Clips for attaching gels and filters to the reflector THE X SERIES CONTROL PANEL pee ee The Back Control Panel on a aa the X Series flash unit offers Q 2 5f 1 4f 1 3f 1 2f 1 1f 1 100 you clear control of the unit s 132 116 1 8 1 4 1 2 FULL r G o m features conveniently labeled and ma collectively loca
7. d allow it to cool If the flash unit is triggered but fails to fire properly the misfire alarm will sound for one second If this alarm sounds first check your flashtube to ensure that it has not broken or come loose f either alarm fires and you are unable to correct the problem please contact our Customer Service Department at 1 800 443 5542 The Housing The units are housed in aircraft grade aluminum extrusions with molded poly carbonate rear bezels Our swivel stand mount is attached to the housing with a tightening knob to attach your unit securely to a light stand and an adjustment arm to change the position and direction of the unit SETUP INSTRUCTIONS 1 Remove the shipping cover Your flash unit arrives with a black polycarbonate shipping cover in place You must remove this cover prior to operation The cover is held in place with four fingers on the faceplate of the unit which are used to hold accessories as well such as reflectors and softbox speedrings To remove the cover slide the silver faceplate release lever to the left This will cause holding fingers on the faceplate to contract allowing you to pull the shipping cover straight off of the faceplate Releasing the lever will allow the holding fingers to expand back into the holding position Please make sure the modeling lamp is installed before using your flash unit 2 Securely mount your flash unit to an appropriate light stand The black swivel mounting brack
8. d cord manufacturer s PC cord While this is rare if you feel that your cord simply won t match please contact us If you have other questions please contact us You can call us on our toll free line at 1 800 443 5542 or on our local line at 615 383 3982 We re here Monday through Friday from 9 00am until 5 00pm CST You can email us as well at info paulcbuff com ABSOLUTE SATISFACTION GUARANTEE Paul C Buff Inc offers a 60 Day Absolute Satisfaction Guarantee If for any reason you are not satisfied with the equipment that you have purchased from Paul C Buff Inc you may return your equipment within 60 days for a complete refund minus the cost of shipping WARRANTY Paul C Buff Inc offers a 5 Year Factory Warranty on all White Lightning X Series X800 X1600 and X3200 flash units The obligation of Paul C Buff Inc is limited to the repair or replacement of products that have become defective under normal use as outlined in the manual The warranty does not apply to the flashtubes or modeling lamps as these become exhausted based on normal use except in the unusual case of an unexpected manufacturer s defect Should you experience any difficulties please contact us so that we can assess your predicament and let you know if we need to bring in your unit for repair This product was Made in the USA by Paul C Buff Inc White Lightning a division of Paul C Buff Inc 2725 Bransford Avenue
9. et allows you to affix your unit to any of our light stands Once you have expanded the footprint of the stand to its stable position set the unit on top of the stand and allow the brass stud to slide inside the opening Use the black knob on the mounting bracket to tighten the screw and secure the position Use the black positioning handle on the bracket to adjust the direction and angle of the flash unit Once your unit is securely mounted and positioned you may then adjust the height of the stand See the images on the following page to learn more positioning handle the brass stud fits inside the stand mount tightens around the brass stud Note The X Series stand mount fits light stands with 5 8 inch or smaller studs 3 Attach your accessories Reflectors To attach any of our reflectors to the faceplate of your flash unit you will use the faceplate lever to expand and contract the holding fingers in the same manner used to remove your shipping cover When you slide the lever to the left the holding fingers will contract allowing you to place your reflector around the fingers When the lever is released the fingers will expand to hold the reflector securely in place For proper fitting ensure that all four fingers are holding the inside of the reflector Softboxes and Octaboxes The speedring of your assembled softbox will fit on the faceplate in place of the reflector attached and removed as the reflec tors are
10. ff Inc remote control for remote operation of functions Slave Tripper SLAVE cell The unit contains a sensitive built in slaver tripper which fires the unit whenever it sees the light from another flash unit or from an infrared signal The slave tripper can be dis engaged by plugging a sync cord or a blank dummy jack into the sync jack Sync Jack The sync jack allows you to connect the unit to your camera with the provided sync cord PC connection When a sync cord or blank dummy plug is connected the slave tripper is disengaged and the unit will only fire from the connected camera The X Series trigger sync voltage is under 6 volts Dump Light The DUMP light indicates the unit s charge overcharge status This light shines red when the unit is charged to a higher flashpower than what is selected when the flash power is changed from a higher to a lower setting To avoid overexposing the next frame wait for the DUMP light to go out the unit will automatically dump the excess charge Depending on the power adjustment made the automatic dump may take up to one full minute but you can instantly dump this charge by pressing the TEST button to flash the unit Circuit Breaker Reset Button The RESET button allows you to reset the circuit breaker if it is tripped from excessive rapid use Pressing this button in will reset the circuit breaker ON OFF AC Power Switch The Powe
11. indicates that the unit has recycled and is ready to flash again at the indicated settings With the switch released the lamp will remain on at the output level indicated through the shoot A 1 pz m gt o lt Recycle Indicator Ready Light The READY light shines green to indicate that the unit is recycled and ready to flash at the indicated settings m 7 4 als ao ale ao SIE k an Q O Test Flash The red TEST button allows you to test flash your unit Range Switch on the X1600 X2400 and X3200 units only The blue RANGE button switches the unit from High Power Full to Low Power 1 4 mode When in High Power mode the unit is using all of its capacitors and the flashpower slider will adjust the output over a stepless 5 f stop power vari ability from Full down to 1 32 power When in Low Power mode the unit is using only one of its capacitors and the flashpower slider will adjust the output over a stepless 5 f stop power variablity from 1 4 down to 1 128 power As the modes overlap there is a total 7 f stop range available When in Low Power mode the flash duration and recycle time is decreased by a factor of 4 and the modeling lamp will be set to dimmed to 1 4 of its power The unit will test flash itself whenever you switch the range Remote Control Jack This standard RJ 11 connector jack accepts the four con ductor telephone cords provided with each Paul C Bu
12. ire button will fire the unit s in your setup and indicate the appropriate settings so that you may set your camera controls accordingly A reading from the camera position or from the subject position may be used to determine an overall average scene reading Depending on the subject you may additionally want to take spot meter readings With these readings you can set your camera s controls appropriately for the amount of light present considering the aperture and shutter speed needed for the specific effect desired Once you have taken your reading made necessary adjustments and set your camera s controls you can remove the sync cord from the meter and return it to your camera You are now ready to shoot Note When metering for a correct exposure you cannot rely on your in camera meter as it cannot detect the light that will be produced by the flash unit s when fired Most cameras employ a Through The Lens Meter TTL which takes light readings by sending out a pre flash in order to detect the amount of available light While this reading has no way of detecting the flash the signal may also inadvertently trip your unit s built in slave tripper causing a premature flash AUTOMATIC VS MANUAL CAMERA MODES The automatic mode is a setting on your camera that allows the camera to use its internal meter to automatically adjust the aperture and shutter speed for a shot based on the prescribed ISO setting and the available light
13. r Switch located above the Power Cord Jack is the main ON OFF switch for the flash unit Power Cord Outlet Each X Series unit is supplied with our 15 foot AC Power Cord to connect the unit to a 120 Vac 50 60 Hz power source The power cord is plugged into this outlet with a standard IEC Connector then into a a grounded power outlet The flash units will not function properly if the ground is defeated For safety using a surge protector is recommended when multiple flash units are plugged into a single outlet FRONT VIEW DIAGRAM umbrella screw dual umbrella holes holding fingers 4 flashtube modeling lamp faceplate release lever expands and contracts the four holding fingers positioning handle stand mount tightening screw light stand brass stud X SERIES FEATURES Built in Cooling Fan While the units incorporate axial flow thermodynamics to reduce heat build up each unit also has a built in forced air cooling fan to prevent overheating The thermostatically controlled fan automatically comes on when temperatures rise from extended use at 104 F Warning Alarms Each unit contains audible warning alarms to indicate overheat and misfire If the unit s temperatures reach higher levels where the internal components may be threatened the unit will produce a periodic tone Continued use will increase the urgency of this tone Should the overheat alarm sound it is best to power down your unit an
14. s use sync voltages as high as 50 60 volts which can damage some cameras Most digital cameras can accept up to 6 volts synced You can check your camera s manual to confirm its maximum allowable sync voltage Q My X Series unit does not fire All I hear is a clicking sound The ready light comes on and the modeling lamp works but there is no flash What does this mean A lf the ready light comes on and you hear a faint click when you push the test button the most likely problem is an exhausted flashtube Flashtubes by design will become exhausted based on use and a new flashtube should fix the problem Q I m having problems with my supplied sync cord fitting into the light and the PC connection on my camera Did get the wrong cord A The sync cord supplied with your flash unit is a 15 foot cord with a 1 4 inch stereo plug on one end and a PC connector on the other end To insure a proper connection you must push both the PC connection and stereo plug in fully until they cannot be pushed in any further Simply pushing the stereo plug in one more click solves many problems of this nature However given manufacturing tolerances it is only natural to get an occasional minus sync cord mating up with a plus camera PC connector and vice versa A PC connector set requires a tight fit to prevent misfires and there are slight size differences occasionally noted between a camera manufacturer s PC outlet an
15. sting any accessories WARNING Do not allow unattended children around studio flash equip ment as potentially dangerous conditions may result including burns and electrical shock hazards Please be safe with your equipment POWER REQUIREMENTS As the X Series units require an AC power source each unit comes with a 15 foot power cord This cord connects to the flash unit on the back control panel with a standard IEC connector and then must be connected to a 120 VAC 50 60 Hz power outlet When shooting in an environment where a suitable AC power source is not available we recommend the exclusive use of one of our Vagabond Portable Power Systems The Vagabond Systems are designed specifically for Paul C Buff Inc flash units and power packs offering a convenient lightweight self contained portable power source at a very low cost please call us or visit our website for specific product details PRODUCT DESCRIPTION The X Series flash units are extremely precise high power electronic photo graphic flash units They are designed for professional studio use as well as demanding location work due to their compact yet highly durable construc tion and extruded housing The flashpower and modeling lamp intensity are continuously variable over a stepless 5 f stop power variability independently adjusted on separate rear panel faders The X1600 and X3200 may addi tionally be switched between HIGH and LOW power modes to add ano
16. ted for simple and j quick manipulation MODEL READY TEST Oe Na Note The Blue RANGE Switch that allows the unit to switch from High Power to Low Power mode is only available on the X1600 and X3200 models j z Manufactured In USA by Paul C Buff Inc Nashville Slider Control of Flashpower The flashpower is independently adjusted with the top slide fader marked with lightning bolts on either side over a complete 5 f stop power variability from Full down to 1 32nd of the total power The slider adjusts the flashpower stepless ly in whole f stop increments and everywhere in between 0 Slider Control of Modeling The modeling lamp output is independently adjusted with the lower slide fader below the flashpower slider marked with light bulbs on either side over the same full 5 f stop power variability Modeling Lamp Control MODEL The white MODEL button is the ON OFF switch for the modeling lamp When depressed the modeling lamp will be turned ON when released the modeling lamp will be turned OFF The lamp must be turned on before the READY feature may be used Modeling Lamp Recycle Indicator MODEL READY The black READY button is the ON OFF switch for the modeling lamp recycle status indicator feature When depressed the lamp will visually indicate the unit s recycle status by dimming after each flash as the unit recycles When the modeling lamp comes back on this
17. ther 2 f stops and to reduce the recycle and flash duration to 1 4 of the normal power The unit delivers energy stored in its internal capacitor bank to a critically matched circular hard glass flashtube designed for S600K daylight spectrum with low UV emission This yields minimal flash duration while maintaining energy conversion efficacy within 1 4 of an f stop of the maximum attainable from Xenon light sources of this type For wireless firing capabilities each X Series unit contains a sensitive built in slave tripper which is disabled when a sync cord or blank dummy plug is inserted into the sync jack Each unit arrives with a 250 Watt quartz modeling lamp This long life bulb is encased in a large frosted glass envelope to eliminate hot spots and pattern errors that are common to small clear envelope household bulbs The unit offers highly accurate modeling boasting what you see is what you get modeling This is a result of careful engineering of the flash and modeling components with respect to polar patterns specular content and accurate tracking of light ratios from both sources With respect to tracking accuracy the units employ full voltage regulation of the flash circuits as well as the modeling lamp circuits allowing the system to maintain consistent flash and model ratios under real world powerline conditions The modeling lamp may be set on FULL power adjusted with the rear panel fader over the same available r
18. with the holding fingers Umbrellas You may use an umbrella with the standard 7 inch reflector or bare bulb Line up the hole in the reflector with either of the dual umbrella holes in the unit s housing The umbrella pole fits through both holes and is then tightened in place with the black screw Honeycomb Grids To use our grids you will need either the standard 7 inch reflector or the UMF LiteMod Unit Mainframe With either reflector attached you can snap one grid directly into the recessed outer lip Gels Filters Our gels filters may be used with the UMF LiteMod Unit Mainframe sliding into the frame using the GELH Gel Holders or with the UBR Background Reflector or standard 7 inch reflector With the reflectors you can use the provided self adhering nylon clips for attachment Please see the individual accessories for a complete description of use and attachment or call us should you need assistance 4 Connect your power cord and turn the unit ON The provided 15 foot power cord connects to the flash unit on the back control panel then plugs in to a 120VAC 50 60Hz power outlet With the power cord connected turn your unit on The green READY light indicates that your unit is powered and ready to fire 5 Connect your sync cord to your camera The 1 4 inch male stereo plug on one end of the provided sync cord plugs in to the sync jack on the back panel of the unit and the other end of the cord will connect to your camer
Download Pdf Manuals
Related Search
Related Contents
LEVANCIO 取扱説明書-基本編-(第4版) 追補版 Varimixer 305N User's Manual ATTACHED) Epson 1280 Printer User Manual Origin Storage 250GB TLC SATA Untitled Incipio SA-574-BLK mobile phone case INSTRUCTION MANUAL GUIDE D`UTILISA TION MANUAL DE Copyright © All rights reserved.