Installation Manual

image

Contents

1. Air inlet Air inlet Air dircharge vent Features and appearance will vary all the figures provide a demonstration to introduce the funtion USE OF UNIT MOUNTED OPERATION PANEL ES ein perator ede racar amp Operation running Telenor Ta Fresh air exchange procedure 1 Remove the front cover by pulling out at the bottom to release it then lit it up to clear the rail along the chassis top Fig a 2 Put the air exchange switch to open state Fig b Figa Figb Note The air exchange switch is normally placed at the left closed position When it is moved to the right the unit will discharge a little amount of air from inside room to keep the air fresh but if the switch is placed at the right position for long time the cooling effect will be affected Our company has provided the thoughtful services for customers and the air conditioner had been installed self diagnosis system to display the code for failure Fallure Code Goniant at defect E C
2. 1 The wall sleeve must be properly installed accoding to the wall sleeve installation instructions Page12 15 2 install the outdoor grille from the room side If replacing and old chassis with an existing grille or using a specialized grille in a new installation please contact our company dealer to determine if the new chassis should be used with the nonstandard specialized grille 3 INSTALLATIOIN 1 Front cover removal Remove the front cover by pulling out at the bottom to release it then lift it up to clear the rail along the chassis top INSTALLATION PROCEDURES 2 Chassis installation Slide the chassis into the wall sleeve until the chassis flanges contact the front edge of the wall sleeve then secure with four screws through the chassis flange holes Wal Sies po Chassis Outhide wan Side Chassis in 3 Wires connection of wall mounted controller optional procedure it is just suitable for wall mounted controller model Firmly connect the electrical junctor of wall mounted controller to the junctor on the right bottom of chassis 4 Front cover installation Reinstall the front cover by hooking the top over the rail along the chassis top then pushing it in at the bottom 4 o 4 TEST OPERATION Connect to power source check to see if the operational mode buttons work properly Check to see if the room temperature control and the function control work properly Check if the water
3. 1Samp 20 amp aE TANDEM PERPENDICULAR TANDEM TYPE TYPE TYPE
4. USERS Read this Manual carefully before using the packaged terminal air conditioner to ensure proper operation of the unit IN ren TO INSTALLATION Make sure that an authorized technician or contractor does the installation for you dh WARNING Make sure that breaker is installed for safe operations 1f breaker is ntinsatled may resutin lec shock or other hava Do not install the unit in a place where there might be leakage of inflammable gases xe In the case That the gases are leaked out and accumulated around the machine t may result in fre hazards or otherl seen Make sure that the power source of the unit is properly grounded the packaged terminal air conestionr id to the grounding wire of hs power ouroe Improper grounding wil isad to possiie Sacre shock Er aier nizat T 0na ii INSTRU ik Do not press stretch damage heat or modify the power cord ore wires lt may rest in Biete shock Srerneatng re Snead or her ecient In the case that fhe power ora ls damaged ot thal a replacement For the power cord is required due to Some oher reasons pisase coniatt our Company dealer or an auinorized nannance technician Pazara Do not use the fuse with improper capacity or other metal Ke Improper Use of metal wires copper ves forthe tuse may raul in auy poriormanves cf tne machine or Pr Do not insent sticks or other hard lobjections into the ai
5. the batteries so as to prevent the leakage of the electrolyte from damaging the hand held remote controller METHODS OF MAINTENANCE Before proceeding with the methods of maintenance make sure that the packaged terminal air conditioner is turned off and the plug is pulled out from the socket Before the operational seasons BB check to see it there are any blocking objects around the air inlet and outlet of the units DD check to see it the installation base is corroded or rusty EJ check ir the grounding is propery made ground wire DD creck ir ie air iter screen is clean E correcto me power source Load batteries in the remote controller remote controller model After the operational seasons Set the temperature at 30 Cor 86 F and let the machine run in cooling mode for half a day Make the interior of the unit dry Stop the operation of the machine and turn off the power switch It is recommended to pull he plug irom the power socket in the non operatonal season tor Pe sake of safety and saving energy Clean the air filter sereen and install it back to place Glean the air conditioner Take the batteries out from the remote controller remote controller model During the operational seasons Clean the air fitar screen at a standard interval of once very Imo weeks E remove ne air iner screen Take out the air fler screen directly grasping it fram the front c
6. WAZmMAZOO uWOEMIAOTM Foreword This Instruction Manual is the standard version for all models for the packaged terminal air conditioners manufactured by our company The appearance of the model that you purchased may be slightly different from the anes described in the Manual but it does not affect the proper operations and usage Please read this Manual carefully and keep the Manual available for reference at a later time Addition to the user manual The packaged terminal air conditioner is not intended for the use of young children or infirm persons without supervision The packaged terminal air conditioner shall be installed in accordance with national wiring regulations ifthe power cord is damaged t must be replaced by qualified person in order to avoid a hazard Due to continual product improvement the right is reserved to change specifications and design without notice This symbols refers to a hazard or unsafe practice which can result in severe personal injury or death EATON This symbols refers to a hazard or unsafe practice which can result in personal injury or product or property damage Contents Instructions to end users Names and functions of various parts Use of unit mounted operation panel Use of wall mounted controller Use of hand held remote controller Methods of maintenance Diagnosis on troubleshooting Installation procedures Wall sleeve installation Cnanee Bs INSTRUCTIONS TO END
7. ad to the Ifcomplete buring ot thase appaances Do not use the following articles Re EE on o fap aaae sree Sra te may ae delanmator or Do not let the delivered air blow to your body directly for Tong time N might cause dlecomion o your Body or harm your health 7 Do not sit on the unit or place heavy objects on it The taling ot the unt might cause bod fries or other ICheck to see if the supporting parts of the units are properly fixed and firm 1 he supporting pata raae Meet males tint ram taling down which might Ease tony mres f arune It the air conditioner is not to be used for a long period of time please pull out the plug from the power source socket to ensure safely Turn off the air conditioner before puling out the plug fal Ifthe unit needs to be removed for installation elsewhere or for repairs please contact our company dealer or authorized technicians In case of occurrence of abnormality burning smell for example please stop the operation of the unit disconnect the power and contact our company dealer or authorized techincians NAMES AND FUNCTIONS OF VARIOUS PARTS Front View Filter screen iii To take out diracty grasping trom here A DIONS a irom here Operation panel Air return grids For intake of room a Front cover Rear View Outdoor grille
8. be used to support the block above the wall sleeve Fig 8 The sleeve can not support the load of bricks blocks if directly under a window silluse of lintel may not be necessary ft ag 114 Bubble Tit To Outside SS Moly or toggle bot 0 Wood screw Shey Expansion anchor bolt Fig7 Note The fastening parts and wood screws etc are prepared by end users themselves D WALL SLEEVE INSTALLATION 5 Weather proofing Weather proofing gaps between the exterior wall and the sleeve with caulking or other equivalent weather proofing material Fig 9 aes wtb Fig Note installation in extra thick walls a Ifthe sleeve is being installed in a thick wall where the sleeve is recessed more than 3 an extended wall sleeve will be required with depths as called out in chart 1 bjif the sleeve is being installed in a wall where the recess 3 or less a flashing must be installed under the sleeve and extend up 2 on each side The flashing must include a drip rail as shown above Fig 9 6 Electrical requirements Provisions should be made to have a proper electrical outlet near the sleeve All wiring must be made in accordance with local codes and regulations The line cord included with the chassis if used will extend to a wall receptacle located with in the area shown in Fig 10 F 58 MODEL WALL RECEPTACLES SEV SOVT 30
9. drainage is smooth and unblocked Check if there are abnormal sounds during operations WALL SLEEVE INSTALLATION To ensure the best performance of the packaged terminal air conditioner please observe the following wall sleeve installation procedures and do the installation in accordance with related requirements 1 Wall sleeve assembly optional procedure a Unpack all parts and accessories referring to Fig 1 assemble the wall sleeve by first cliplocking the side pieces to the bottom piece then the top piece to the assembled side and top pieces b Handle the wall sieeve carefully ol the wall sleeve is deformed chassis installation may be hindered If the wall sleeve has become deformed straighten it before installing it in the wall Se fh rA IA ee Fig 1 2 Wall sleeve location When making the wall opening please observe the following requirements The air inlet and outlet should be unblocked and the air can be delivered to every comer of the room b Install the unit in places that are away from heat sources or sources of inflammable gases c install the unit in places that are not directly exposed to sunlight d Do not install the unit in places that are subject to strong wind or dust Do not install the unit in places where the operational noise and exhausted air might trouble your neighbors There should be sufficient space margins around the unit to facilitate maintenance and repairs refer to F
10. e air conditioner wil prevent he un ion cooling operator There is no sufficient cooling or heating Ts the room temperature set properiy blocked 1 the air fiter screen clean not Are the doors or windows opened Is the room directly exposed to sunlight Hot e Are there any heating sources inside the room 1 Are there many people inside the room he packaged terminal air condones remains abnormal in oparatin aliar the above the pdwer ana carck our company dele or aahonced twa In any of the following cases please turn off the power of the packaged terminal air conditioner and immediately contact the dealer or authorized technician hacks and inspection please daconnect The tuse is frequently blown or the breaker keeps shutting 5 me The electric abnormally hot The insulation sheath of the power cord is torn wire turns f The switches do not work There are abnormal noises when the machine is operating INSTALLATION PROCEDURES A To ensure the unit operates safely and eficientiy it must be installed by qualified or experienced technicians The appliance must be installed in accordance with national wiring regulations It the supply cord is damaged t must be replaced by the manufacturer service agent or a qualified technician in order to avoid a hazard 1 NAMES OF PARTS 2 WALL SLEEVE AND OUTDOOR GRILLE
11. h Using Feld supplied sieeve angles TEA 212 ee age TSS at usingTeld supplied sleeve angles 16 14 4217F 16 18 24 sleeve dimensions Note 1 equals to 25 4mm please refer to using WALL SLEEVE INSTALLATION If the field supplied case angles must be used during installation Fig 5 proceed as follows a Position the case angles around top and sides of sleeve to get the proper depth be sure to have the angles pointing outside Mark the sleeve using the case angles as a template for screws c Drill 5 32 hole at the marked position irom step 2 above only use 10X1 2 screws d Install the screws from the outside of the sleeve do not drill any holes in the base of the sleeve 4 Installation of the sleeve in the wall opening a Place sleeve into the wall refer to Chart 1 D2 for room side projection minimum 1 2 to a maximum 1 3 4 without subbase The rear outside edge of the sleeve should stick out a min of 1 4 past the outside wall to be able to caulk properiy do not seal the drain holes on the outside grile side ot sleeve it is desired to have the rear grille flush on the outside a drip rail must be installed under the sleeve and caulking applied between the drip rail and sleeve b To ensure the unit s maximum efficiency the sleeve must be installed a slight downward pitch rom the indoor side to the outdoor side Fig 6 then fasten the wall sleeve Fig 7 c Lintels should
12. h the GLK button The time indicator is flickering and can set the presen Soe Press the HOUR button set to AM 10 00 am a gt Press the MIN button set to 30 ae Pres the CLK button again and then close the back cover de Timer operation procedure Timed switch off During the operation press the TIMER button and the unit wll enter the timed switch off mode Press the HOUR button to set the desired time the timer can make the setting in the range from 1 12 hours After the setting the digits shown on the display screen will go down by 1 for every elapsed hour Timed switch on In the standby mode press the TIMER button and the unit will enter the timed switch on mode Pres the HOUR button to set the desired time the timer can make the setting in the range from 1 12 hours After the setting the digits shown on the display screen will go dawn by 1 for every elapsed hour Releasing procedure Press the TIMER button again to release the mode Replacement of batteries When the signal from the remote controller becomes Weak and the unit can not receive it properly or the indication on the display screen becomes blurred please replace the hand held remote controller with two new batteries Note 1 The positive and negative poles must match the installation positions 2 Do not use an old battery together with a new battery 3 If the hand held remote controller is not to be used for long time take out
13. igs 2 and 3 Critical dimensions N CEAL X Fig2 Fig3 Note Care should be taken in location of electrical supply entry in relationship to the sleeve for later access refer to Fig 10 2 WALL SLEEVE INSTALLATION Chart 1 Dimensions Recommended installation clearance bt Top of case to finished ceiling 3 min Projection of case into room 1 2 minimum up to 1 ue 3 4 maximum without use of electrical sub base Note 2 3 8 minmum when sub base is used Da Minimum projection of case to the ouisida 1 Height above finished foor or top of carpet 1 2 mirimum bs recommended without sub base 3 minimum with sub base D5 Leftight side of case to adjacent wall 3 Preparation of the wall The sleeve should be installed during construction and lintels should be used to support the block above the wall sleeve The sleeve can not support the load of bricks blocks For existing construction wall opening must be created the proper dimensions are necessary to avoid use of fillers or additional framing The sleeve is modular in height and width refer to Fig 48 Chart 2 Height Fits 2 courses concrete block Fits 6 courses standard brick Fits 5 courses jumbo brick Width Fits approximately 3 stud spaces Fig 4 Chart 2 minium finished lopening dimensions aight width aight width dept
14. ommunication Faure Ez indoor col Temperature sensor Taare E Indoor Temperature sensor Taare Er Syalam abnormally provacon E Guldoor cal Temperatura sensor Talore E Ovarheaing Potesio Detrasing OF Datrasing USE OF WALL MOUNTED CONTROLLER Wall mounted controller and hand held remote controller are optional parts please read the sections corresponding to the specific model you have choosen d ie ott hooh l pe 3 e Een Paeroa OF ONOFF a gitar tow Ff eee aera i rarer bat von Note 1 Do not use nails or other sharp objects to press the button because the sharp objects wil scratch the panel 2 Pressing the WARM and COOL buttons together beyond 3 seconds can lock the panel keyboard and pressing the two buttons again would cancel the lock function 3 When you tum on the machine if the wall mounted controller is connected there will be 4 seconds delay for operating the controlle In this time the unit mounted operation panel and hand held remote controller will not work but the digital pipe and indication lamp of operation panel can work the wall mounted controller is disconnected there will be 3 5 seconds delay for operating the unit mounted operation panel and you will be able to operate the machine with hand held remote controller It it is in the situation of starting up before powe
15. over coll Ly BD cican ne air ter screen I the air fiter screen is very diry you may use tewarmn wate about SO or io chean t and enar tay Note Do not use boing water to clean the screen Do not bake the sereen dr Da not put wth foo much oroe ED ist the air fiter screen W cian the air conditioner Use sott dry cioth to wipe their conattonar or use a Vuum cleaner i do the Caan condone is very sed howsehold Iotergent to do the Note It the air fiter screen is blocked by dust the performance of cooling and heating operations will be affected the operational noise will be larger and the power consumption will be increased Therefore periodic cleaning of the air filter screen is necessary DIAGNOSIS ON TROUBLESHOOTING Inspection and treatment prior to maintenance Please check the following items before asking our company dealer or authorized technician for after sale services The packaged terminal air conditioner does not work at all Is the power plug inserted into the socket properly my as p Is there a power failure or is the fuse blown 1s the timer set for the TIMER ON mode I the packages terminal air conditioner remote controller modal fs efor imed swich on operation mode i wil nat Siart operating before the set ime ts reached Ts the ambient temperature lower than 16 C or 61 F 1t so the auto protection function o h
16. r cutting off the PTAC wil start up automatically after the power is on The LED will display it immediately following the memorial content and the relay will do the time delay start up according to random numbers 120 240 seconds This function can prevent from the accident of electric network surge when the same type of air conditioners are installed in the same property and start up in the same time after power is supplied USE OF HAND HELD REMOTE CONTROLLER mo MUME ponm i aml 6 Se a s 8 88 3B rere owore Ta The a Q sachet naan gr Pe YO Bcd nnd Fe a Above figure shows all indications for the purpose of explanation practically only the applicable is indicated Cool Fan Heat mode operation procedu Press the ON OFF button with the remote controller pointing toward the packaged terminal air conditioner Press the MODE button select the operation mode cool fanv heat Press or button to set your desired temperature The setting temperature range is 61 88 F 16 31 C Press the FAN SPEED button to set your desired air flow rate high mid low USE OF HAND HELD REMOTE CONTROLLER Present time setting procedure When cells are inserted the present time is automatically set to AM 0 00 EX set to AM10 30 Open the back cover pus
17. r inlet or outlet The high speed rotation of he an blades may cause scadents Do not place such arlicles as insecticides paints or other flammable spraying agents near the packaged terminal air conditioner or spray them against the air conditioner Omo tight resultin fre hazards 1 the air conditioner and the burning appliances have to be used in the same room try to get good ventilation in the room Yertlation may lead to the Do not wash the air conditioner with water 1t may cause elect shock ar other oa INSTRUCTIONS TO END USERS CAUTION Do not try to stop the operation of the packaged terminal ai conditioner by pulling the power cable from the socket This could result in sactc shock fre Taza or oiner accents Make sure that there is no dust on the plug before you plug in the power socket and make sure the plug is put correctly plugged into the socket href dust on tha plug or the piaga ais not Pi eaula recut n slecrie shock fee hazards ot Difer accidents Try as much as possible to avoid the sunlight and warm air from entering the room During the cooing operation window ural or louver Binas as be used fo shada of the sunlight Try to reduce the generation of heat in the room during cooling operations Place the heating source outside of the room i possible do not use burnin appliances in the air condition room eP tk may le