1. Part Description Connecting with Computer D Displa Display Setting Model Display Sample Description DR100 IY 1A A A L Recording Interval 1 Second Open the connector cover Default Settin r tla l Ini Sampling 10 ms and the temperature and humidity are alternately displayed Corner Holders 9 DRO1 DR20 o TAL TET TLL Z L Recording Interval 1 Second Open the cover of the USB connector I2 Hen ee t iJm Sampling 10 ms and the temperature and humidity are alternately displayed LCD MiniB 1S indicates the recording interval is 1 second 10m indicates the sampling cycle 1M is displayed when the recording interval is 1 minute Ge Sampling Cycle Response Frequency Display Display When Trace Mode is On 20msec 100Hz i A himn THC chirm Alternately displayed lt A Connect the USB cable 10msec 100Hz a l fam TRE Hr Z Alternately displayed Insert the USB connector MiniB end of the 5msec 100Hz IA Hm TEI Egem Alternately displayed provided USB cable 7 40Hz Mee Gr Eedi et Eyra N Alternately displayed 7 20Hz H Gm TIA Ehm Alternately displayed 2msec 100Hz I Am TRIO ffm Alternately displayed
2. 3 Connect with your computer voz ke tm TREZ Zm N Altematety displayed Tapped holes for Connect the USB TYPE A end of the provided attachment plates USB cable with the USB port on your 2 45Hz IH tr PEAN LA etrr 2 Alternately displayed computer E W E Battery Chamber Cover P 25Hz y H g r k i k c m Alternately displayed 1msec 100Hz l A l a THC T rr Alternately displayed A 70Hz H l n HPRH LA f irf Alternately displayed p 45Hz NH l n RIH i rr Alternately displayed 25Hz VE him TEIE ot a ff 2 Alternately displayed Battery AA Alkaline a Chamber A Batteries LR6 x2 old D eh eetl ry a a W is displayed to show that the threshold has been set How to mount Attachment Plates s Trigger standing by Pree diim _ are alternately displayed The threshold triggers the trace mode to stand by Trigger measurement TO ira F W L i B awara of the mouriting direction in progress Pret tem Triggered to start measuring and p and are alternately displayed during measurement Warnings Data capacity is full c par T pa rt i i Warning and measurement conditions are alternately displayed See how the attachment plate is mounted as How to Install Batteries shown inthe sketch i i iT Battery is low DA S a N a A i _ Recording stopped nth ttery chamber cover Excess over Le ee ee A S ni ON 1 Ope e battery chamber cove threshold detect
3. Cycle of 10 msec Operating Temperature and WENO Humidity Range 0 50 C RH less than 70 no condensation Measurement 75 5 H x60 5 W x33 D mm Weight Approximately 135g including batteries USB Cable AA Alkaline Batteries 2 Warning Sticker Accessories Attachment Plates 2 Software CD ROM Safety Precautions Definition Failure to follow these instructions could result in death or serious injury Failure to follow these instructions could result in mild or moderate injury Symbols and Conventions A Warnings A Caution A Warning includes Caution A The description is shown in the pictogram The example at left indicates General Caution Warning Danger S Prohibited Avoid The description is shown in the pictogram X The example at left indicates Dismantling Prohibited Compulsory Required The description is shown in the pictogram The example at left indicates Remove plug from socket Please read the following instructions and the User s Manual carefully prior to use This device is limited to use as attached and packaged with the object to be measured Do not drop the device and avoid excessive impact Do not use for objects relevant to human or animal life This device is not a high precision electronic measuring instrument Do not dismantle or attempt to modify the device Do not use or store under the following conditions Extremely high tem
4. a E MEN G GRAVITY SHOCK RECORDER User s Manual G MEN DR01 DR20 DR100 Thank you for your purchase Please read the User s Manual carefully prior to use S IC SRIC Corporation SRIC Corporation http www sric co jp E info box sric co jp 2014 10 Accessories Od a EUSB Cable MiniB WAA Alkaline Batteries LR6 WMagnet G Trace E Attachment Plates WApplication Software WWarning Sticker WUser Registration Card WStartup Guide WUser s Manual WWarranty Certificate About the G MEN 3 Axis Direction Symbol G MEN measures the acceleration with 3 direction sensors X Y and Z Each sensor detects positive and negative force Graphs and CSV data depict acceleration with values of X Y and Z axes and signs The G MEN 3 Axis Direction Symbol A Direction WCopying or reproduction of this User s Manual in part or in whole without prior authorization is strictly prohibited Specifications design and any other information included in this User s Manual may be revised without prior notice HiTo the best of our knowledge this User s Manual is accurate at the time of printing but should you encounter any omissions or inaccuracies please contact your dealer or our Customer Support MiThis product is designed and manufactured for use within Japan This product is designed to be used while attached and packaged with the
5. a gas CEI of acceleration to date Install the unit by securing the Attachemnt Tha rhi tt 10 G on Z axis on August 28th at 14 11 4 Close the battery chamber cover Plate s using appropriate screws onto an II 1 I object to be measured s Ir SA i cnme Put back the battery chamber cover and 04 ae a 0 ee De D Displays the current number of records tighten the screw securely SSS SS 05 He eee Displays the date and time March 30th 16 20
6. ed S ai Aa ee A I Excess over the threshold is detected when the option is turned ON Loosen the screw with a screw driver A cd T E n T j1 r Excess over the threshold is measured displayed for 1 second A Mount one of the attachment plates Hazard t S kera measuremen _ h H L l k cl Displayed after 1 000 hazard recordings and then measurement is halted Tighten the screw with a screwdriver to fix the ae IGIIT T maim attachment plate on one side of the body Starting Idling time wrt ot wt Counts down for 5 seconds F IIIT That nee i A Remove the battery chamber cover Magnet trigger WIL nA Standing by for magnet start l a Preset ee ee ee are alternately displayed The preset starting date and time is shown Make it ready for putting in the batteries ee ee gt the example at left indicates the 31st at 12 30 j Te cola 3 Do the same with the other side Stopping SLE Measurement is suspended Es f Mount each attachment plate to the both sides Display Options 00 i a i Ni Standard operation Measurement conditions Temperature and humidity Putting in the batteries of the body n 01 Di Ly ww Displays the acceleration of X and Y axes Install the AA Alkaline Batteries LR6 2 TIm ATAT correctly as indicated with 02 bowl ey ID number and the acceleration of Z axis 03 ME Oty oS pa Fix the unit to an object to be S ol Alternately displays maximum measurement axis and the date and time measured 17 0
7. erting the battery make sure the positive and negative ends are facing the correct direction HiWhen not in use for an extended period of time take the battery out before storing WAiways hold the plug when connecting and disconnecting the USB cable provided WNever handle with wet hands HiKeep the product and batteries out of reach of children Specifications Model G MEN DRO1 G MEN DR20 G MEN DR100 Measurement 3 Axis Acceleration Temperature Humidity 3 Axis Acceleration Temperature Humidity 3 Axis Acceleration Temperature Humidity Acceleration Sensor 1G 2G Passive Acceleration Precision 10 Precision 10 Precision 10 10G 100G Precision 10 Precision 10 Gravitational accleration is not supported Measurement Resolution 0 01G 0 02G 0 1G 1G Response Frequency OHz 100Hz OHz 100Hz 16Hz 100Hz Temperature 0 50 C 1 25 C Humidity 30 90 43 Sampling Cycles 5 Cycles 1 msec 2 msec 5 msec 10 msec 20 msec Recording Interval 1 5 10 15 20 30 secs 1 2 3 4 5 10 15 20 30 minutes Selectable Display LCD Recording Capacity 32 000 data 1 data Date time X Axis Y Axis Z Axis Temperature Humidity Record Saving EEPROM Connection USB miniB 2 0 Operating System Requirement Windows 32 64bit Power Source AA Alkaline Batteries LR6 x2 Battery Life Approximately 50 days at Sampling
8. not described in this Manual is strictly prohibited HOperating Systems compatible with this product is limited SRIC will not be liable for any damages incurred if the user does not use the product correctly or has handled it in any way other than described herein or has tampered with or changed it in any way or if it has been repaired or changed in any way by a third party For your safety please read the Safety Precautions and the User s Manual carefully prior to use Usage WThis product cannot be used under water at high altitudes up high in the air or where there is no gravity WThis product cannot be used where the temperature range is under 0 C or over 50 C Placement HDo not leave the product under direct sunlight near any heat source inside closed vehicles or freezers Power Supply Replace with new batteries before use When not in use for an extended period of time remove batteries before storage WAccidental swallowing of batteries is dangerous Keep out of reach of children Warranty Win no event will SRIC be liable for any direct or indirect damages of any kind incurred by the results of using this product HOperation cannot be guaranteed for usage other than described in this Manual Repairs WFor maintenance during and after the warranty period please contact your dealer or our Customer Support HDo not scratch the surface or spill water on the liquid crystal display panel HiWhen ins
9. object to be measured Please handle with care as excessive direct impact may damage this product This product is not intended for monitors and such equipment relevant to human and animal lives WThis product is not an instrument specializing in measuring acceleration WThis product is a data logger which records acceleration and temperature over an extended period of time Win no event will SRIC be liable for any direct or indirect damages of any kind incurred by the results of using this product MiThis product is designed and manufactured to ensure high reliability however absolute operation guarantee is not possible If this product use is intended for providing proof for compensation for damages or insurance claims of high value the use of multiple products is recommended This product is intended for use under normal living conditions and cannot be used under condensation oil water or extreme temperatures Operation and data are not guaranteed under high energy radiation The user is responsible for the operating environment of this product This product is battery operated It will run stably for approximately one month with new batteries but if you intend to record for an extended period of time be sure to use new batteries The USB Universal Serial Bus standard used herein is HSSI WLogos and Windows7 used herein are trademarks of Microsoft Corporation Win this Manual marks such as TM R C have been omitted WUsage
10. peratures Under direct sunlight near heaters Extremely low temperatures In the refrigerator in extremely cold weather Near water In the bathroom on the water at sea in the water in the sea Areas affected by acid alkaline organic solvents corrosive gases etc It depends on measurement environment and battery performance Inquiries to Support Center Hinquiry to Support Center are restricted to those who have registered as a user Information required 1 User s address name and telephone number 2 Product model number in use 3 Usage environment The model name of the apparatus connected 4 Present condition in detail Support Center e mail support box g men jp WFor repairs check the items below and contact your dealer or our Customer Support HAs a general rule the user is responsible for the cost of delivering the product for repairs You will not be charged for the cost of receiving your product after repairs Please attach a note stating the circumstances of the The following will void your warranty and any repairs will be subject to a fee Failure to present the Warranty Certificate 2 Incomplete Warranty Certificate 3 Damage caused by incorrect use or caused by accidents after purchase 4 Unauthorized modification or changes to the product

Download Pdf Manuals

image

Related Search

Related Contents

Guardian A5-6000 System  Tandberg Data DAT72 and DAT160 SCSI tape drives user guide  Philips 2000 series Blu-ray Disc player BDP2700  ASUS (ME170C) User's Manual  Newstar FPMA-D1330DWHITE flat panel desk mount  G2 credle dcr 50 user manual 110110  pdf-edition-page-8-sur-18-metz-vallee-de-l-orne-du-16-05-2013-1  Goodmans GS103TZH User Guide v5.indd  Transport de poudre résiduelle du récipient de récupération  ソルベントナフサ,米山薬品工業 ,CE0018,2013年1月7日, 安全データ  