Home
USER MANUAL / OPERATION INSTRUCTION
Contents
1. 5 6 BOPNORUES 64 71 ao Psd 72 79 80 87 A O even it fr jns pas jee a faso 9080 SCROLLING Fast to slow FORWARD 4 285 JG OBO SCROLLING Fastto slow REVERSE
2. sure that the power cord is never crimped or damaged by sharp edges Check the device and the power cord from time to time Always disconnect from the mains when the device is not in use or before cleaning it Only handle the power cord by the plug Never pull out the plug by tugging the power cord During the initial start up some smoke or smell may arise This is a normal process and does not necessarily mean that the device is defective Caution During the operation the housing becomes very hot Do not touch while HOT Do not switch the device On or Off in short intervals as this would reduce the lamp s life Keep away from children and non qualified users OPERATING DETERMINATIONS This device is a lighting effect for creating decorative entertainment lighting effects This product is only allowed to be operated with an alternating voltage of 120 V 60 Hz and was designed for indoor use only This device is designed for professional use on stages in discotheques theatres etc Lighting effects are not designed for permanent operation Consistent operation breaks will ensure that the device will serve you for a long time without defects Do not shake the device Avoid brute force when installing or operating the device When choosing the installation spot please make sure that the device is not exposed to extreme heat moisture or dust There should not be any cables lying around You endanger your own and the safety of o
3. 14 gobos open and blackout Strobe effect with adjustable speed 1 10 flashes sec via shutter DMX controlled operation or stand alone operation with Master Slave function e Sound controlled via built in microphone Fuzzy Sound Control program continues automatically during periods without music or bass beat Control Board with 4 digit display Digital DMX focus For MSD HSD 250 MSD 250 2 or MSD HSD 200 lamp DMX control via every standard DMX controller 4 DMX control or 6 if Rotating Gobos channels required PROSCAN 250 DMX Scanner INTRODUCTION Thank you for having chosen METEOR KLS PROSCAN 250 You will see you have acguired a powerful and versatile device It has been designed to be very flexible and user friendly without compromising effectiveness or professionalism Unpack your PROSCAN 250 Before your initial start up please make sure that there is no damage caused by transportation Should there be any guestions or problems consult your dealer and do NOT use the device SAFETY INSTRUCTIONS notes written in this user manual CAUTION Be careful with your operations With a dangerous voltage you can suffer a dangerous electric shock when touching the wires This PROSCAN 250 has left our factory in absolutely perfect condition In order to maintain this condition and to ensure a safe operation it is absolutely necessary for the user to follow the safety instructions and follow all the warnings Important Damages
4. PROSCAN 250 USER MANUAL OPERATION INSTRUCTION USER MANUAL INDEX PROSCAN 250 DMX Scanner Keep this manual for future needs Putitin a place that you can access it if needed Table of contents USER MANUAL INSTRUCTIONS FEATURES INTRODUCTION USER MANUAL INSTRUCTIONS SAFETY INSTRUCTIONS OPERATING DETERMINATIONS USER MANUAL INSTRUCTIONS RROOONN OVERVIEW INSTALLATION OH D ode ao o eas Installing Replacing the lamp Lamp adjustment ss Master Slave operation DMX 512 connection connection between Fixtures Connection with the mains 0 0 00 4000 Oi OPERATION mit deat ema acosa Stand Alone DMX controlled operation Addressing om E DMX PIOIOCOL hd e aatatel eun dos ProMover 250 channel features Setting DMX Channel Stand alone LCD oo Oo q 0 gt Features Innovative DJ scanner with or without Rotating gobos R G version 12 different dichroic color filters and white Rainbow effect with adjustable speed in both directions Gobowheel with
5. caused by the disregard of this user manual are not subject to warranty The dealer will not accept liability for any resulting defects or problems CAUTION Keep this device away from rain and moisture Unplug mains lead before opening the housing SAFETY INSTRUCTIONS For your own safety please read this user manual carefully before your initial start up Every person involved with the installation operation and maintenance of this device has to be qualified follow the instructions of this manual consider this manual to be part of the total product keep this manual for the entire service life of the product pass this manual on to future owners or users of this product include every supplementary update with the original manual If the device has been exposed to drastic temperature fluctuation e g after transportation Do NOT switch it on immediately Allow fixture to reach normal room temperature By not doing so the water condensation might damage your device and cause severe damage to lamp and circuit boards Leave the device switched off until it has reached room temperature This device falls under protection Class I The power plug must only be plugged into a protection Class outlet Never let the power cord come into contact with other cables Handle the power cord and all connections to the mains with particular caution Make sure that the available voltage is not higher than stated on the rear panel Make
6. do not attempt the installation yourself but instead use a professional structural rigger Improper installation can result in bodily injury and or damage to property The device has to be installed out of the reach of people If the device shall be lowered from the ceiling or high joists professional trussing systems have to be used The device must never be fixed swinging freely in the room Caution Devices in hanging installations may cause severe injuries if not properly mounted and secured correctly with appropriate back up failsafe rigging If you have doubts concerning the safety of a possible installation Do NOT install the device Before rigging make sure that the installation area can hold a minimum point load of 10 times the device s weight Master Slave operation The master slave operation enables that several devices can be synchronized and controlled by one Master device On the TOP panel of the PROSCAN 250 you can find an XLR jack DMX Out and an XLR plug DMX In which can be used for connecting several devices Choose the fixture that is to control the effects This device then works as Master device and controls all other slave devices which are to be connected to the master device via a balanced microphone lead Connect the DMX OUT jack with the DMX IN plug of the next device DANGER OF FIRE When installing the device make sure there is no highly inflammable material decoration articles etc withi
7. er must only carry out the installation The installation of the device has to be built and constructed in a way that it can hold 10 times the weight for 1 hour without any harming deformation The installation must always be secured with a secondary safety attachment e g an appropriate catch net This secondary safety attachment must be constructed in a way that no part of the installation can fall down When rigging or de rigging or servicing the device staying in the area below the installation place on bridges under high working places and other endangered areas is forbidden The operator has to make sure that safety relating and machine technical installations are approved by an expert before taking into operation for the first time and after changes before taking into operation another The operator has to make sure that safety relating and machine technical installations are approved by an expert after every four year in the course of an acceptance test The operator has to make sure that a skilled person approves safety relating and machine technical installations once a year Procedure The device should be installed outside areas where persons may walk by or be seated IMPORTANT OVERHEAD RIGGING REQUIRES EXTENSIVE EXPERIENCE including but not limited to calculating working load limits installation material being used and periodic safety inspection of all installation material and the device If you lack these qualifications
8. h other XLR outputs you need to use adapter cables Building a serial DMX chain Connect the DMX output of the first fixture in the DMX chain with the DMX input of the next fixture Always connect one output with the input of the next fixture until all fixtures are connected Caution At the last fixture the DMX cable has to be terminated with a terminator Solder a 120 ohm resistor between Signal and Signal into a 3 pin XLR plug and plug it in the DMX output of the last fixture OPERATION After you connected the fixture to the mains the PROSCAN 250 starts running resetting During the Reset the motors are trimmed and the device is ready for use afterwards Stand Alone operation In the Stand Alone mode the PROSCAN 250 can be used without controller You can do without a controller as the PROSCAN 250 features a built in microphone which provides automatic sound control Disconnect the PROSCAN 250 from the controller and select Master Mode Sound control MASTER SLAVE operation Connect the master and slave devices and adjust the settings as described above Please note f you wish to change from one operating mode into another you have to unplug the PROSCAN 250 from the mains and plug it again Resets units DMX controlled operation You can control the projectors individually via your DMX controller Every DMX channel has a different occupation with different features In order to call up the different feature
9. n a distance of min 0 5 m Mount the device to your trussing system using an appropriate clamp For overhead use always install a safety rope that can hold at least 12 times the weight of the fixture You must only use safety ropes with guick link with screw cap Pull the safety rope through the attachment eyelet and over the trussing system or a safe fixation spot Insert the end in the guick link and tighten the safety screw The maximum drop distance must never exceed 20 cm A safety rope which already held the strain of a crash or that is defective must not be used again Adjust the desired inclination angle via the mounting bracket and tighten the fixation screws DANGER TO LIFE Before taking into operation for the first time the installation has to be approved by an expert Connection with the mains Connect the device to the mains with the enclosed power supply cable DMX 512 connection connection between fixtures The wires must not come into contact with each other otherwise the fixtures will not work at all or will not work properly Only use a stereo shielded cable and 3 pin XLR plugs and connectors in order to connect the controller with the fixture or one fixture with another Occupation of the XLR connection If you are using controllers with this occupation you can connect the DMX output of the controller directly with the DMX input of the first fixture in the DMX chain If you wish to connect DMX controllers wit
10. s you first have to open the shutter control channel 6 DMX value 132 139 or 250 255 or set the dimmer to the desired intensity control channel 6 DMX value 6 128 Addressing The Control Board on the front side of the base allows you to assign the DMX fixture address which is defined as the first channel from which the PROSCAN 250 will respond to the controller If you set for example the base address to channel 12 the PROSCAN 250 will use channels 12 to 23 for control Next available DMX value would be set for 24 Please be sure that you don t have any overlapping channels in order to control each PROSCAN 250 correctly and independently from any other fixture on the DMX data link If two three or more PROSCAN 250 s are addressed similarly they will work similarly Before you attempt to operate this unit make sure you have no unanswered questions PROSCAN 250 4 Channels DMX FUNCTION DMXVALUE FEATURESTATIRIBUTES ___ pa 0 255 Moves Mirror on HORIZONTAL AXIS Lr o z Moves Mirror on VERTICAL AXIS E ma MAGENTA LEON BLUE 44 54 s 318 PURPLE AAA e YELLOW is 109 DEN 120 ANG 121 127 DARK GREEN 128 190 RAINBOW SCROLLING FORWARD AS RANBOW SCROLLING BACKWARDS 4 4 8080 OT BLACKOUT PEN REDUCTION GOBO pst sane ooo pee OPEN ARE TT leer
11. ther operation may lead to dangers like short circuit burns electric shock and lamp explosion Lamps and fuse replacements are not covered under warranty OVERVIEW PROSCAN 250 DANGER TO LIFE Only install the lamp with the device switched off and not plugged into power Always unplug power from mains before attempting any service For the installation you need one MSD 250 2 GY 9 5 lamp The lamp must only be changed when wearing appropriate protective clothing protection glasses protection gloves helmet with sight leather apron INSTALLATION Installing Replacing the lamp Procedure CAUTION The lamp has to be replaced when it is damaged or deformed due to the heat The lamp life given by the manufacturer must never be exceeded This is why you need to take notes on the operational time of the lamp and replace the lamp in time Keep exchanged lamp in a protective container and remove accordingly During the operation the lamp reaches temperatures of up to 600 C Before replacing the lamp unplug mains lead and let the lamp cool down approx 10 minutes During the installation do not touch the glass bulbs barehanded Please follow the lamp manufacturer s notes Do not install lamps with a higher wattage Lamps with a higher wattage generate temperatures the device was not designed for Damages caused by non observance are not subject to warranty Step 1 Unscrew the fixation screws X Y of the lamp system and caref
12. thers The symbol m determines the minimum distance from lighted objects The minimum distance between light output and the illuminated surface must be more than 0 5 meters This device is only allowed for suspended installation via the mounting bracket In order to safeguard sufficient ventilation leave 50 cm of free space around the device Make sure that the area below the installation place is blocked off when rigging derigging or servicing the fixture Always secure the fixture with an appropriate safety rope and proper rigging hardware designed to hold more than 10 times the weight of the fixture proper industry standard Never look directly into the light source as sensitive persons may suffer an epileptic shock The maximum ambient temperature t 45 C must never be exceeded Operate the device only after having become familiar with its functions Do not permit operation by persons not qualified for operating the device Most damages are the result of unprofessional operation Please use the original packaging if the device is to be transported Please consider that unauthorized modifications on the device are forbidden due to safety reasons and will void any warranty Never remove the serial barcode from the device as this would make the warranty void If this device will be operated in any way different to the one described in this manual the product may suffer damages and the warranty becomes void Furthermore any o
13. ully remove it from the housing Step 2 If replacing the lamp remove the old lamp from the lamp holder Step 3 Insert the lamp into the lamp holder Step 4 Replace the lamp system in the housing and tighten the fixation screws Step 5 Adjust the lamp as described under lamp adjustment Do not operate this device with opened cover Lamp adjustment The lamp holder is aligned at the factory Due to differences between lamps fine adjustment may improve light performance Strike the lamp open the shutter and set the dimmer intensity to 100 and focus the light on a flat surface wall Center the hot spot the brightest part of the beam using the 3 adjustment screws A B C Turn one screw at a time to drag the hot spot diagonally across the projected image If you cannot detect a hotspot adjust the lamp until the light is even To reduce a hot spot pull the lamp in by turning all three screws A B C clockwise 1 4 turn at a time until the light is evenly distributed If the light is brighter around the edge than itis in the center or if light output is low the lamp is too far back in the reflector Push the lamp out by turning the screws A B C counterclockwise 1 4 turn at a time the light is bright and evenly distributed Overhead Rigging if the main attachment fails as a secondary back up DANGER TO LIFE Please consider the DIN 15560 and the respective national norms during the installation An authorized deal
Download Pdf Manuals
Related Search
Related Contents
DPR 15 marzo 2010, n. 90 (1). - Marina Militare ResMed Sleep Apnea Machine AutoSet CS User's Manual Sony SLV-M91HF VHS VCR Bedienungsanleitung KLX300 Changing the Jets in a Mikuni car... 1055KB Feb 23 2011 "取扱説明書" Zusammenbau- und Bedienungsanleitung - Ersatzteilliste für Réalisation de la LPE par FAH parallèle Samsung CS-29M21SPQ Инструкция по использованию User Manual - Fast Forward Video Copyright © All rights reserved.