1. C Fit battery case cover 12 2 5 6 How to recharge the rechargeable battery pack in the cradle lt gt this is only possible for the terminal with rechargeable battery pack in a cradle with tranceiver charger function There are 2 ways for recharging the rechargeable battery pack UM By removing the battery pack out of the terminal and putting it in the battery holder of the cradle i e charging separate battery pack in cradle s battery holder Recharge time will be approx 1 hour E By placing the whole terminal with battery pack in it on the cradle i e charging battery pack inside terminal Recharge time will be approx 4 hours Charging separate battery pack in cradle s battery holder transceiver charger model Quick charge Place the rechargeable battery pack in the battery holder on the cradle UD After checking the battery status indicated by blinking green LED the recharging starts indicated by by a solid blinking red LED UD After approx 1 hour the charging is completed indicated by a solid blinking green LED Refresh discharge A rechargeable battery has an so called memory effect which deteriorates full charging when recharging is executed before the battery capacity becomes empty When the memory effect is recognised activate the refresh discharge Use this feature sparingly when too often used it may damage the battery Place the rechargeable battery pack in
2. O Insert the handle in the thin loop O Do not swing the terminal around Start with a full battery UD To be sure you start with a full battery charge the battery pack according to the instructions in the next chapter UD Click the battery pack into the terminal as instructed in the next chapter 2 4 2 Cradle Place for mounting DO Place the cradle in normal office conditions Avoid a place under strong light Otherwise IrDa communication may be disturbed Wall mount panel When the cradle is mounted on the wall the wall mount panel will keep the terminal on its position As a second function the panel will protect the IrDa window from both terminal and cradle from direct sunlight DO First mount the wall mount panel on the cradle Locate the place for mounting and attach the base plate by tape Mark the position of the holes of the base plate ref 1 Remove the base plate Screw in the screws with spacers on the marked positions ref 2 UD Align the body with its mounting holes to the spacers ref 3 Slide down the body and fix it on the wall Wall mounting instructions _77 SCREWS Da lt ya t 2 WALL A MOUNT PANEL K S DY LES A WY NA e Ze f i AA AN x A BASE pan SNS WL q A a A For power connection see next page USER S MANUAL PHL 1700 LASER TERMINAL IRU 1600 CRADL
3. When the terminal has a problem with reading the label lt gt The resolution of the bar code is too high UD Decrease the distance between the bar code and the terminal USER S MANUAL PHL 1700 LASER TERMINAL IRU 1600 CRADLE lt gt The angle between the label and the terminal is too high UD Change the angle between the bar code and the terminal amp The distance is too far or too close E Change the distance between the bar code and the terminal lt gt The bar code is larger than the laser beam E Try moving the terminal a bit further away from the bar code The read window is dirty UD Clean the read window of the terminal amp The type of the bar code label is not enabled Enable the bar code symbology in the application program 7 3 BATTERY CHARGING PROBLEMS When the terminal is placed in the cradle the main battery is not charged lt gt Red LED indicator is not turned on O The battery pack in the terminal is not empty enough The battery voltage has to be lower than 2 6 V E If the battery temperature reaches 45 C the charger will stop charging immediately The cradle is waiting for the proper temperature 0 40 C and will then continue E The cradle needs a rechargeable battery pack to charge When a battery holder for dry cell batteries Is used the charger does not work at all UD There is no contact between the terminal and the cradle Try again to place the termin
4. needs service Cradle does still not operate and needs a service Send the cradle to your supplier for service paying attention to the limited warranty USER S MANUAL PHL 1700 LASER TERMINAL IRU 1600 CRADLE PRODUCT ORDERING INFORMATION Apart from the terminal additional items might be ordered Article Code Terminal D PHL 1700 10 1MB A73700R0010 E PHL 1700 20 2MB A73700R0030 Battery Pack for terminal El Rechargeable Battery Pack 02510000020 Dry Cell Battery Pack Assy 02510000030 assy case holder penlite batteries O Battery Case Holder Q2510000060 O Penlite Batteries PBA30000010 Cables for terminal RS232 cable DB 9 female 02500000020 E Modem cable DB 25 male 02500000030 Protective Bags for terminal DO Leather bag 02510000050 E Leather bag clip 02510000060 Nylon bag 02510000070 Software development tools UD Microtec ANSI C cross compiler 08010000010 E C library for handheld terminals D4030000020 Application Generator Potstar Limited D6010000010 O Application Generator Potstar Professional D6020000010 Apart from the cradle additional items might be ordered Cradle D O Power Supply for cradle D O o IRU1600 S transceiver IRU1600 C transceiver charger 5V DC adaptor for IRU1600 C 9V DC adaptor for IRU1600 S Euro Cable Cables for cradle UD RS232 cable DB 9 female O o D Adapter DB25 female DB9 male Modem cable
5. DB 25 male RS485 cable Article Code 02520000010 02520000015 A50100N0020 A50200N0020 A79000N0030 02520000020 P10AT000040 02520000040 02520000050 23 USER S MANUAL PHL 1700 LASER TERMINAL IRU 1600 CRADLE Opticon Article Code 00220000020 24
6. Message Application halted or No application installed is shown O There is no user s application for PHL1700 loaded in the terminal Contact your supplier For example pressing the shift key does not toggle the shift indicator O There is a flaw in the application program Disconnect the battery pack and place it then back in The terminal will be in off state Activate the system menu and restart the application or download new application O If problems appears continously contact the supplier of the user s application Terminal gets no power when pressing the powerkey The main battery is exhausted Replace the battery pack or charge the terminal in the cradle Laser stays off when pressing the triggerkey amp Power is off O The triggerkey is no powerkey Press the powerkey to get power DO If the terminal is not used the scanner will switch off all functions Press the powerkey to reactivate lt gt Laser temperature has become too high O The laser is switched off automatically when thelaser temperature becomes above 50 C Wait until the temperature has dropped 22 Terminal does still not operate and needs a service Send the terminal to your supplier for service paying attention to the limited warranty 7 5 CRADLE PROBLEMS Indications on the cradle amp Power indicator of cradle is off O No power supply Check the adaptor When the adaptor is good the cradle
7. gt Never remove the main battery pack while the terminal is turned on Doing so can cause data in the terminal to be deleted gt Insert full batteries before use of the terminal 4 when you do not use the terminal for a long time make sure the main battery has enough capacity When there is not enough capacity the backup battery will be used up USER S MANUAL PHL 1700 LASER TERMINAL IRU 1600 CRADLE 2 5 1 Required batteries The terminal needs both main battery and backup battery for operation Main Battery The main battery can consist of ET Rechargeable Opticon battery pack NiMH to be recharged when placing the terminal PHL2700 in the cradle IRU2700 dr KA E Dry cel Opticon batteries Alkaline To be used together with Opticon battery case for dry cell batteries These batteries are not rechargeable C Other batteries All batteries have to be used together with Opticon battery case for dry cell batteries Batteries that are not supplied by Opticon must be AA size and absolutely leakproof If rechargeable batteries are used they need to be recharged by a separate battery charging device Opticon recommends to use Opticon batteries Opticon rechargeable battery pack or Opticon dry cell batteries only Backup Battery Use only one type of battery for backup UD Backup battery CR2032 Li Lithium button type 2 5 2 When to replace or recharge the main battery There are 2 reasons for re
8. refresh discharge NiMH pack only for the model transceiver charger 12 Wall mounting holes USER S MANUAL PHL 1700 LASER TERMINAL IRU 1600 CRADLE 2 3 HANDLING PRECAUTIONS To avoid malfunctioning and to ensure years of trouble free operation pay attention to the following General use Do not use or leave the product in extremely hot areas like direct sunlight near a heater or in a car or in areas that are very cold humid moistured or dusty Do not expose the product to rain or water splash SRI PRL Youd Do not subject the the product to very strong impact do not throw or drop the terminal from large heights Do not allow a mechanical shock to the product Oo General cleaning instructions Clean the exterior by wiping it with a soft dry cloth Do not use much water or other solvents These can discolour the case and the keys and has a negative effect on the lifetime of the keys Do not use thinner white spirit Use of the cradle Do not place any other product than the PHL type terminal in the cradle Cleaning of the cradle Avoid touching the contacts in the cradle The contacts must stay as clean as possible to maintain optimal charging capacity Do not use water when cleaning the cradle This can cause malfunction in the chargers Use of the terminal Operate the terminal keys by pressing them lightly with your fingertips or with something soft and round Pressing the k
9. transceiver charger y 3 AC adaptor LP depending on the model 9V DC adaptor for transceiver O 5V DC adaptor for transceiver charger Wall mount panel screws Walll mount spacer screws base plate USER S MANUAL PHL 1700 LASER TERMINAL IRU 1600 CRADLE 2 2 DETAILED VIEW 2 2 1 Dimensions of terminal ww pp WW g9 172 mm 2 2 1 Details of terminal oS ww ZE ww 11 13 14 10 12 Reading window laser beam for barcode reading will be emitted from here Optical interface window for infra red communication LCD Display for displaying information LED indicator can be used to indicate results for example bar code reading status of communication Trigger key definable by user s application typical use read key switches laser beam on for barcode reading Quick keys definable by user s application typical use menu scroll keys or yes no input Power key right key NOT definable for switching power On Off Control keys definable by user s application for controlling basic functions typical use as below CLR Cancel input BS Back space S Shift key S on the LCD display indicates the terminal is in the shift mode Character keys definable by user s application typical use for input of alpha numeric and punctuation characters ENT key definable by user s applic
10. AL PHL 1700 LASER TERMINAL IRU 1600 CRADLE SCANNING BAR CODES Please take care of the handling precautions lt gt Please make sure that the terminal is installed according to the installation instructions Never remove the main battery pack while the terminal is turned on Doing so can cause data in the terminal to be deleted or corrupted 4 1 Scan Position When reading a small bar code decrease the distance between the terminal and the bar code For larger bar codes position the terminal so that the bar code fits into the laser beam When reading a very high density bar code decrease the distance between the terminal and the bar code For a low density bar code increase the distance between the terminal and bar code 4 2 Reading the bar codes The scanning sequence is defined by the user s application A typical sequence is O Press the PW key to turn power on Check the display for the message READ BAR CODE E Point the terminal to the bar code and press the Trigger key D Point the laserbeam to the barcode as shown in the scan position illustration UD The barcode will be read and the reading results will be indicated 16 The terminal is a Class laser product conforming to the strictest laser safety standards However we recommend that you avoid looking directly into the laser beam emitter or pointing the laser beam directly into someone s eyes Fit the bar code
11. D 3 3 RD 4 4 SD 5 5 SD 6 2 Modem cable Modular DB 25 DB 25 plug Signal connector Signal male 10 pins Male Gi 1 DC IN 2 DC IN A gt 3 TxD 2 RxD 4 RxD 3 TxD 5 RTS 4 CTS 6 CTS 5 RTS Ed DTR 20 DSR 8 DSR 6 DTR 11111 9 GND 7 GND Cr 10 GND A F ay 6 9 E El 9 DB9 DB9 male Signal female Signal In Out Note cradle PC cradle 3 TxD 2 RxD OUT 7 2 RxD 3 TxD IN 6 1 DSR 4 DTR not used 5 GND 5 GND 4 DTR 6 1 DSR OUT ON fixed 8 CTS 7 RTS not used 7 RTS 8 CTS OUT ON fixed 17 USER s MANUAL PHL 1700 LASER TERMINAL IRU 1600 CRADLE SPECIFICATIONS 6 1 SPECIFICATIONS TERMINAL 6 1 1 Electrical specifications Main battery 0 0 D Main battery 0 operating time Luni D Backup battery Backup battery operating time Battery O management Charging method E 18 rechargeable pack Ni MH dry cell Alkaline penlite optional other 2 x AA size penlite Ni MH When making every 5 seonds 1 scan with 1 sec laserbeam on and 0 2 sec green LED on and 0 2 sec buzzer on operating time is approx 34 hours Alkaline When making every 5 seonds 1 scan with 1 sec laserbeam on and 0 2 sec green LED on and 0 2 sec buzzer on operating time is approx 67 hours Different operation conditions affect the operating time Use of other penlite batteries affect the opera
12. E Power Connection lt gt Make sure that you use the right power supply lt gt Use for the cradle with transceiver 9V DC adaptor lt gt Use for the cradle with transceiver charger 5V DC adaptor E Attach the DC Jacket onto the body Then connect the AC adapter to the outlet D Power on the unit by the power switch Power indicator turns on indicated by a red LED D When a terminal is placed the LED turns into green 2 4 3 Terminal on cradle Place the terminal on the cradle as shown in the illustration gt La a E lt gt Do not place any other product than the PHL 1700 terminal in the IRU 1600 cradle 10 2 5 INSTALLING REPLACING AND CHARGING BATTERIES Wrong use of batteries might cause serious damage to the terminal or to the cradle In order to avoid damage it is very important to take notice of the instructions Follow the instructions for installing changing and removing the batteries very strictly The products are not warranted for damage defects malfunction or loss of data resulting from incorrect use of batteries lt gt only use recommended batteries When other batteries are used defects or other problems can occur Before installing new batteries please make sure you are using the recommended batteries lt gt Do not make a mistake regarding the polarity of the battery The terminal will not work when the polarity is incorrect
13. EM CONNECTOR OPERATION OF THE TERMINAL The functionality of the terminal is determined by software the so called user application that is running on the terminal Usually the terminal is not equipped with software and has no functionality At first the user application must be loaded before the terminal can be used for barcode scanning Tools for developing a user application on the PC for use on the terminal as supplied by Opticon are Application Generator PotStar Limited or Professional E C language Microtec ANSI C compiler and C library for handheld terminals The user application must be downloaded from the PC into the terminal You can use the cradle an RS232 cable or an infrared adapter for communication between the terminal and the PC A program on the PC will send the user application to the terminal where it is stored in FlashROM memory When the functionality of the terminal is defined by the application it is ready for operation In a typical application you will press the trigger key and scan a bar code label as described in the next chapter Scanned data and data entered from the keyboard is stored in the terminal s RAM The user application can use this data in subsequent steps The collected data can be transmitted to the PC for further processing For data transmission you can use the cradle an RS232 cable or an infrared adapter to connect the terminal to the PC 15 USER S MANU
14. INSTALLATION 2 1 UNPACKING When you remove the packing please check for any physical damage We recommend that you save all packing material as it should be used whenever you need to ship your terminal eg for service Damage due to improper repacking is not covered by the warranty Apart from the terminal or cradle additional items might be ordered and supplied If there are any missing parts please contact your supplier PHL1700 Terminal Terminal X can be delivered as 7 E model with dry cell batteries model with rechargeable battery pack Battery case depending on the model Z there are 2 options CA LEE WA lt gt O Battery case with ee 2x AA size dry cell penlite batteries UD NiMH rechargeable battery pack 1 x A ee O Backup battery Hand strap Do not remove the label On the back of every unit you will find a label The label is attached by the manufacturer and includes information about the function it supports and a serial number Do not remove it ja rtnr 02520000015 serial l nr 000001 IRU 1600 transceiver charger Pi Jito A Additional items only supplied if ordered RS232 download cable for terminal Modem cable for terminal Protective bag for terminal RS485 cable for cradle Modem cable for cradle O O RS232 cable for cradle O O IRU1600 Cradle Cradle body can be delivered as 5 O transceiver pr O
15. U The first and the last cradle in the network must have the termination resistors set by DIPswitch En Eran Ln Fran ae i RS 232 TT TERMINATED RS 485 RS 485 TERMINATED sw 1 on sw 1 off sw 7 on sw 7 on sw 8 on sw 8 on 14 USER S MANUAL PHL 1700 LASER TERMINAL IRU 1600 CRADLE 2 6 4 Dip switch settings on cradle Setting the DIP switches on or off will result in enabled or disabled functions of the cradle CI Open the cover of the DIP switches on the bottom of the cradle in order to reach the DIP switches Turn the DIP switch ON by moving it up E Turn the DIP switch OFF by moving it down DIP SWITCH FUNCTIONS ON OFF SW 1 RS 232 inuse not ON for connection in use sw2 SPARE DIP SWITCH OFF ON SW 3 SPARE Ch sw4 SPARE SW 5 SPARE SW 6 SPARE SW7 RS485 inuse not TERMINATOR in use SW 8 RS485 inuse not TERMINATOR in use 2 6 5 Connect terminal to computer DB25 DB9 HOST j LEY Lo E NN 10 PINS RS 232 CONNECTOR 2 6 6 Connect terminal to modem af ON We O Line PH WEY OFF E i DB25 RS 232 10 PINS i MOD
16. User s Manual Laser Terminal PHL 1700 Cradle IRU 1600 USER S MANUAL PHL 1700 LASER TERMINAL IRU 1600 CRADLE CAUTION This user s manual may be revised or withdrawn at any time without prior notice Copyright 2000 Opticon Sensors Europe B V All rights reserved This manual may not in whole or in part be copied photocopied reproduced translated or converted to any electronic or machine readable form without prior written consent of Opticon Sensors Europe Limited warranty and disclaimers By opening the package of this product you agree to become bound by the liability and warranty conditions as described below Under all circumstances this manual should be read attentively before installing and or using the product In no event Opticon Sensors Europe will be liable for any direct indirect consequential or incidental damages arising out of use or inability to use both the hardware and software even if Opticon has been informed about the possibility of such damages A serial number appears on all Opticon products This official registration number is strictly related to the device purchased Make sure that the serial number appearing on your Opticon device has not been removed Servicing by our Repair Department can only be carried out under warranty All Opticon products are warranted for a period of one year after purchase covering defects in material and workmanship Opticon will repair or at its opinion re
17. al properly or clean the contacts lt gt Terminal is still not charged Red LED indicator is turned on UD The charger for the terminal is probably defect Take the battery pack out of the terminal and charge it in the battery pack charger The cradle will need service but can still operate for a while When a rechargeable battery pack is placed in the cradle the main battery is not charged amp Green LED indicator is not turned on not flashing O The cradle needs a rechargeable battery pack to charge When a battery holder for dry cell batteries is used charger does not work at all DO The battery voltage reaches 4 V The voltage for charging should be between 2 4 V lt gt Green LED indicator keeps flashing O The battery is too cold or too warm The cradle is waiting for the proper temperature 0 40 C and will then continue amp The rechargeable battery pack is still not charged Red LED indicator keeps on E The charger for the battery pack is probably defect Put the battery pack in the terminal and charge it in the terminal charger The cradle will need service but can still operate for a while Backupbattery is empty lt gt Indicator in the display of the terminal is on O Replace the Lithium CR2032 battery with a new one 21 USER S MANUAL PHL 1700 LASER TERMINAL IRU 1600 CRADLE 7 4 TERMINAL PROBLEMS Terminal does not respond to keypresses while the display stays on
18. ation typical use for confirming input Function keys definable by user s application user programmable keys to be used together with shift key typical use as shown on next page Battery case cover for housing main battery RS 232C connector for connecting external device or for system expansion through Opticon RS232 cable Hand strap pillar for attaching hand strap Charging contacts only for the model with rechargeable battery pack USER S MANUAL PHL 1700 LASER TERMINAL IRU 1600 CRADLE Description of the function keys In the shift mode back light on off contrast adjustment and cursor movement can be done by these keys The users application can give different definitions to the keys shift mode functions F1 input minus sign F2 DEL delete one character F3 SP input space F4 BL toggle with back light F5 lt F6 gt move cursor F7 A4 F8 W adjust contrast 2 2 3 Display of terminal The liquid crystal display of the terminal is typically used to show program prompts instructions and data as defined in the user s application The display has the following default options Special purpose symbols in display The symbols will be shown in the bottom part of the display and indicate status CA S Description of the display indicators CO 1 Main Battery indicator Off Sufficient battery power On Battery low Replace battery immediat
19. ely EA Backup Battery indicator Off Sufficient battery power On Battery low Replace battery immediately S Alpha mode on Shift key activated Backlight The display is provided with a backlight When the backlight is turned on the power consumption increases To extend the life time of your batteries use the backlight as little as possible USER S MANUAL PHL 1700 LASER TERMINAL IRU 1600 CRADLE 2 2 4 Dimensions of the cradle WW ALL i de 1 RS 232 C socket for connecting to PC or modem through Opticon RS232 cable 2 RS 485 socket for connecting another cradle in multi drop RS485 network through Opticon RS485 cable 3 LED indicator indicating status of POWER red poweron green terminal is on cradle SD RD red receive data green send data BATT red charging battery green charging is ready BATT status is only for the model transceiver charger 4 Switch for terminal detection to detect if a terminal is placed on the cradle 5 DC input socket input for AC adaptor 6 Power switch 7 DIP switches setting parameters of the infra red interface switches are located behind the cover 8 Data Transmission Interface for optical data transmission 9 Contact for recharging only for the model transceiver charger 10 Battery holder for recharging quick charge NiMH pack only for the model transceiver charger 11 Refresh switch
20. ery slot 1 hour full charge 6 2 3 Functionality Interfaces supported O RS232 O RS485 Serial communication RS232 Baudrate 1200 38400 O RS485 Baudrate 1200 38400 Transmission modes ID Half duplex RS232 E Half duplex RS485 Parity Odd Even None 6 2 4 Environmental specifications Temperature 0 40 C in operation 20 70 C in storage Humidity E 30 85 in operation non condensing DO 30 90 in storage Shock vibration cycle for X Y Z 10 50 Hz with 1G for 30 min Emission According to EN50081 part 1 Immunity According to EN50082 part 1 6 2 5 Physical specifications Dimensions Ixwxd 228 x 116 x 97 mm desk top type Case material ABS Weight D IRU 1600 S excl cables 500 g E IRU 1600 C excl cables 525 g Standard connector i RS232 D Sub 9P Female RS485 6 pins modular plug a 19 USER S MANUAL PHL 1700 LASER TERMINAL IRU 1600 CRADLE TROUBLE SHOOTING This chapter contains information on solving problems you may encounter when using the terminal and or cradle If problems occur first carry out some general checks before verifying the problem with the descriptions in this chapter General checks D Make sure everything is installed properly O Check the power supply of all devices E Is the read window of the terminal clean D Is the optical window of the cradle clean UD Are the bar code labels readable eg not damaged or poorly pri
21. eys with a sharp pointed object for eg a ball point can damage the keys Avoid temperature changes Sudden temperature changes can cause condensation to form on the terminal Using the terminal while condensation is present can cause malfunction Always wait until the condensa tion clears naturally before attempting operation Do not leave the terminal in an area where static charge is Na VAS accumulated or near devices where electromagnetic emission is generated Do not place any objects on top of the terminal Do not lay the terminal face down Doing so can cause accidental operation of the PW key or ENTER key which can discharge your batteries or change settings you do not want to be changed Cleaning of the terminal Clean the optical interface window periodically Maintenance There are no user serviceable parts inside the terminal or the cradle So do not try to take it apart The manufacturer will not be liable for any damage caused by the customer In case of malfunction that can not be solved by the trouble shooting instruction in the appendix please consult our service department USER S MANUAL PHL 1700 LASER TERMINAL IRU 1600 CRADLE 2 4 ASSEMBLY Follow the next steps to make your terminal ready for installation in a system that is described further in the manual 2 4 1 Terminal To avoid drop use the hand strap Fix the small cord of the strap around the pillar
22. in the laser beam from margin to margin and pass the scanner downward over the bar code as shown in the scan position illustration N gt incorrect read scan positions good read scan position pini A Good Read means that the scanner has effectively recognised and decoded the bar code In most cases the application program will provide an indicator signal or a buzzer signal to indicate a good read to the user When the read is incorrect you can try again paying attention to the instructions stated below 4 3 If you have problems with the read operation UD Change the angle between the bar code and the terminal Change the distance between the bar code and the terminal UD If the bar code is larger than the laser beam try moving the terminal a bit further away from the bar code USER S MANUAL PHL 1700 LASER TERMINAL IRU 1600 CRADLE 5 PIN OUT 5 1 RS232C cable for terminal PHL1700 5 2 Modem cable for terminal PHL1700 5 3 RS485 cable for network of cradle IRU1600 5 4 RS232 cable for cradle IRU1600 RS232 cable DB9 female Network cable RS485 Il Ta 1 o Modular DB9 plug Signal connector Signal 10 pins Female 1 DC IN 2 DC IN 3 TxD 2 RxD 4 RxD 3 TxD 5 RTS 8 CTS 6 CTS 7 RTS DTR 6 DSR 8 DSR 4 DTR 9 GND 5 GND 10 GND 1 1 6 6 Modular Modular plug plug Signal 6P6 6P6 1 z 2 2 R
23. nnect cradle to computer Connect cradle to modem Connect network of cradles Dip switch settings on cradle Connect terminal to computer Connect terminal to modem 13 14 14 14 14 15 15 15 OPERATION OF THE TERMINAL 15 SCANNING BAR CODES SCAN POSITION Reading the bar codes If you have problems with the read operation 16 16 16 16 USER S MANUAL PHL 1700 LASER TERMINAL IRU 1600 CRADLE page 5 PIN OUT 17 5 1 RS232C cable for terminal PHL1700 17 5 2 Modem cable for terminal PHL1700 17 5 3 RS485 cable for network of cradle IRU1600 17 5 4 RS232 cable for cradle IRU1600 17 6 SPECIFICATIONS 18 6 1 SPECIFICATIONS TERMINAL 18 6 1 1 Electrical specifications 18 6 1 2 Optical specifications 18 6 1 3 Physical specifications 18 6 1 4 Functionality 18 6 1 5 Environmental specifications 19 6 1 6 Supported symbologies 19 6 2 SPECIFICATION CRADLE 19 6 2 1 Cradle models 19 6 2 2 Electrical specifications 19 6 2 3 Functionality 19 6 2 4 Environmental specifications 19 6 2 5 Physical specifications 19 7 TROUBLESHOOTING 20 7 1 COMMUNICATION PROBLEMS 20 7 2 READ OPERATION PROBLEMS 20 7 3 BATTERY CHARGING PROBLEMS 21 7 4 TERMINAL PROBLEMS 22 7 5 CRADLE PROBLEMS 22 8 PRODUCT ORDERING INFORMATION 23 The general use and functioning of the terminal together with the cradle will be described in this manual The exact behavior of the terminal depends on the user application that is running For instructions about a
24. nted If the equipment still does not work after these checks have been performed please verify if one of the problems described in this chapter applies to the problem you have with the scanner It is possible that you may not solve the problems despite our descriptions In this instance please contact your dealer or Opticon When the terminal needs to be repaired please ensure that the label with the serial number is still present If sending the terminal or cradle please use the original packing to minimise the chances of damage 20 7 1 COMMUNICATION PROBLEMS No communication from the cradle to the device or data is transmitted distorted or corrupted Power indicator of the cradle is not green Clean the optical interface window of the cradle and or terminal and try again Check all cables When the power indicator is still not green the cradle needs service lt gt No data transmitted UD The cradle will only work if connected to aPC 9 Data is corrupted or no data is transmitted C Is the proper baudrate selected The computer needs the same baudrate as the terminal D Is the baudrate between the min and max value For RS 232 baudrate 1200 38400 For RS 485 baudrate 1200 38400 The terminal looses data when the battery pack is removed for a short period 9 The backup battery is empty O Replace the Lithium CR2032 battery with a new one 7 2 READ OPERATION PROBLEMS
25. pin out of the connectors use the cables supplied by the manufacturer 4 when you need another cable for a certain device that is not supplied contact your supplier to purchase the right cable In case another cable is used take notice of the pin out specifications further in this manual Connection sequence for single cradle C Place the cradle in normal office conditions avoid a place under strong light UM Disconnect the power supply UD Connect the interface cables ET Connect the power supply Place the terminal in the cradle TRANSMISSION HOST 2 6 1 Connect cradle to computer DB25 DB9 m 8888888 l o bE Z X DB9 CRADLE RS 232 2 6 2 Connect cradle to modem ON bal C LINE PH E DB9 i DB25 CRADLE HS 282 i MODEM 2 6 3 Connect network of cradles Connection sequence for cradle in network E Only 1 cradle in the network will be connected to the PC through one RS232 cable On this cradle the DIPswitch for RS232 connection must be enabled Through this connection all cradles can communicate to the PC C A maximum of 16 cradles can be connected in a network through RS485 cables For the cradles that are not directly connected to the PC the DIPswitch for RS232 connection must be set to off
26. place products that prove to be defective in material or workmanship under proper use during the warranty period Opticon will not be liable in case modifications are made by the customer In such case the standard repair charge will be applicable The standard charge for repair will also be applicable in case no defect is found at all These rules also apply for products that are still under warranty Therefore you are advised to have the product specifications always at hand Trademarks used are property of their respective owners PHL ver4 00 printed 12 00 1 2 1 2 2 2 2 1 2 2 2 2 2 3 2 2 4 2 2 5 2 3 2 4 2 4 1 2 4 2 2 4 3 2 5 2 5 1 2 5 2 2 5 3 2 5 4 2 5 5 2 5 6 2 5 7 2 6 2 6 1 2 6 2 2 6 3 2 6 4 2 6 5 2 6 6 4 1 4 3 INTRODUCTION INSTALLATION UNPACKING DETAILED VIEW Dimensions of terminal Details of terminal Display of terminal Dimensions of cradle Details of cradle HANDLING PRECAUTIONS ASSEMBLY Terminal Cradle Terminal on cradle page 3 4 N Y O 01 O Ol e O 0 00 INSTALLING REPLACING AND CHARGING BATTERIES Required batteries When to replace or recharge the main battery When to replace the backup battery How to remove the main battery How to install the main battery 11 12 How to recharge the rechargeable battery pack in the cradle 12 How to re place the backup battery in the terminal INSTALLING IN A SYSTEM Co
27. placing or charging the main battery E as soon as possible after the battery indicator appears on the display D when you are not using the terminal for an extended period For instructions of re placing the main battery see paragraph 2 5 4 and 2 5 5 For instructions for charging the rechargeable battery pack see paragraph 2 5 6 2 5 3 When to replace the backup battery When low battery mark G appears replace the battery without delay For instructions of re placing the backup battery see paragraph 2 5 7 2 5 4 How to remove the main battery C Remove the battery case cover Press the shaped part with some force and pull it up UD Remove the entire battery case cover E To take the battery Case out pull one side 11 USER S MANUAL PHL 1700 LASER TERMINAL IRU 1600 CRADLE 2 5 5 How to install the main battery Before installing a battery case with penlite batteries OO Make sure you use the right battery size O Place 2 batteries in the battery holder aligning plus and minus ends as shown on the battery holder The instructions for installing the battery pack are also applicable for the battery holder with penlite batteries 4 J U Remove the battery case cover Press the shaped part with some force and oY pull it up C Remove the entire battery case cover OO Make sure that the direction of the battery case is correct and put the battery case in
28. pplications please consult the documentation of that software Please read this manual carefully before using the terminal to maximise the efficiency of this terminal 1 INTRODUCTION This terminal is a compact programmable handheld terminal and is well suited for a variety of indoor portable applications It has a built in laser scanner that can scan all popular bar code labels at varying distances User s applications can be downloaded to the terminal to adapt the terminal to the user s situation Operating power is supplied by the main battery The main battery may consist of a rechargeable Ni MH battery pack to be charged in cradle or dry cell batteries either non rechargeable or rechargeable to be charged in an external charger The cradle can be equipped with a transceiver function only for terminals with dry cell batteries this will be sufficient The cradle can also be equipped with both transceiver and charger The charger is needed for terminals with a rechargable battery pack The IrDA interface on the terminal enables you to communicate with other devices that use IrDA communication like portable computers notebooks and organisers Additionally a RS232 cable can be used The RS232 cable can be used for direct communication between the host computer system and the terminal for example to download software to the terminal USER S MANUAL PHL 1700 LASER TERMINAL IRU 1600 CRADLE 2
29. the battery holder on the cradle UD Press the refresh switch and discharging starts indicated by an orange LED E The discharge completes in approx 4 hours and the quick charge follows immediately USER S MANUAL PHL 1700 LASER TERMINAL IRU 1600 CRADLE Charging battery pack inside terminal transceiver charger model UD Place the terminal in the cradle E The battery will be charged during approx 4 hours The application in the terminal determines the indication of the charging procedure as if applicable shown to the user 2 5 7 How to re place the backup battery in the terminal Make sure that the main battery is full enough while changing the backup battery D oniy use CR2032 Li Lithium button type battery C Remove the battery case cover Press the shaped part with some force and pull it up C Remove the entire battery case cover D Open the lid of the holder for the backup battery DO If applicable Remove old battery using a pointed object for easy removal Make sure that the positive side of the new backup battery is pointed upwards Place the backup battery Close the holder Close the battery case cover 13 USER S MANUAL PHL 1700 LASER TERMINAL IRU 1600 CRADLE 2 6 INSTALLING IN A SYSTEM lt gt Exercise caution at all times when working with AC powered equipment Tum off your devices before installation gt Because of the special
30. ting time Lithium CR2032 If fully charged 4 months backup time Low voltage indicated on the terminal display DO When battery is low the terminal switches off automatically Rechargeable Ni MH pack in terminal via cradle Replacement Ni MH pack in cradle 6 1 2 Optical specifications Light source Scan rate Decode rate Reading width Resolution at PCS 0 9 Depth of field 650 nm visible laser diode 100 scans sec 100 decodes sec 60 mm at 30 mm 98 mm at 100 mm 0 15 mm 6mil 0 140 mm at PCS 0 9 res 0 25 6 1 3 Physical specifications Dimensions I x w x d Case material Weight Direct cable optional 6 1 4 Functionality Memory Microprocessor Real time clock Display Keyboard Trigger mode Programming Interfaces supported Transmission speed 172 x 62 x 44 mm ABS body excl battery 180 g RS232 DB9 female ROM 32 kB FlashROM for O S and program 256 kB fast RAM 2kB battery backed up S RAM for data 1 or 2 MB 16 bit Quartz RTC time and date programmable leap year handling accuracy 60 sec month I 96x48 Pixels graphic LCD with backlight O Character fonts 4 8 lines x 16 characters D 27 keys total 26 keys user definable E 8 Function keys DO Alpha Numeric mode oa na Manual Functionality is provided by user application The application may be downloaded from PC via cable com port or IrDA O RS232 by direct cable RS232 b
31. y cradle IrDA on terminal RS232 direct cable 2400 115200 baud RS232 cradle 2400 38400 baud IrDA terminal 2400 115200 baud a a a a USER S MANUAL PHL 1700 LASER TERMINAL IRU 1600 CRADLE 6 1 5 Environmental specifications Temperature Humidity non condensing Shock drop Shock vibration cycle for X Y Z Ambient light rejection Emission Immunity Protection against dust and moisture Safety Laser class 0 50C in operation 10 60 C in storage O D 20 80 in operation E 20 90 in storage 1 5 m drop onto concrete surface 10 50 Hz with 1G for 30 min According to EN50081 part 1 According to EN50082 part 1 According to IEC529 IP 42 According to 1EC825 Class laserproduct 6 1 6 Supported symbologies Chinese Post 20f5 Codabar incl ABC and CX Code 39 Code 93 Code 128 EAN 8 incl 2 5 EAN 13 incl 2 5 IATA Industrial 20f5 Interleaved 20f5 Italian Pharmaceutical Laetus Matrix 20f5 MSI Plessey UK Plessey S Code Telepen UPC A incl 2 5 UPC E incl 2 5 fluorescent 3 000 lux max E direct sun 50 000 lux max 6 2 SPECIFICATIONS CRADLE 6 2 1 Cradle models IRU 1600 S datatransmission only E IRU 1600 C datatransmission battery charging 6 2 2 Electrical specifications Battery charging time when battery in terminal for IRU 1600 C 4 hours extra charge with 70 nominal capacity E when battery in spare batt