1. Press 1 Main unit stops alarming and Arm it stops calling users Press 2 Main unit stops alarming and Disarm it stops calling users Press 3 Siren off and monitors the scene for 30 seconds for continued monitoring press 3 again to monitor for another 30 seconds Press 4 Main unit starts a 30 second two way intercom During this time the main unit cannot be controlled by the mobile until 30 seconds later 7 Remote Control Dial the number associated to the alarm main unit by phone mobile phone and after one ringing cycle you can hear a voice prompt Please enter password If the password is right you will here Press 1 to arm Press 2 to disarm Press 3 to Monitor Press 4 to Intercom If the password is wrong you will hear a prompt voice wrong password please re enter Press 1 arm if finished successfully you will hear a voice prompt System armed Press 2 disarm if finished successfully you will hear a voice prompt System disarmed Press 3 monitoring for 30 seconds to continue monitoring press 3 again to monitor for another 30 seconds Press 4 two way intercom for 30 seconds You can t operate the main unit during this time 17 8 Emergency Help Press Emergency Oy button on keypad or Ay button on remote controller or wireless panic button the main unit will alarm and make call to the preset user numbers 9 System Dialing Function In disarm s
2. Checking Although the alarm system is used everyday periodical maintenance and test are required to assure that it can run stably reliably and safely Usually thorough test must be performed on the alarm main unit every three months You d better check the detector once a month if not permitted by condition you should check it at least every three months Check the main unit 1 Whether it can arm disarm normally 2 Whether it can dial the number for alarm normally 3 Whether it can receive wireless detectors signal normally 4 Whether the back up battery can work normally Check the wireless detectors 1 Trigger wireless detectors to see if system can alarm normally 2 Check all detectors batteries to see if it s in low voltage 3 Check whether wireless detectors can send signal to the main unit normally 11 Notes Please do not disassemble repair and alter the products without permission or it may cause accidents and faults Do not drop this product on the ground or on hard objects as it may lead to massive impact to cause faults and damages 19 Technical Parameters List 1 Input Voltage DC12V 1A Standby Current lt 5SmA Alarming Current lt 450mA Wireless Frequency 433 315MHz 2262 4 7MQ GSM Frequency 900 1800 1900MHz Back up Battery NI HI AAA 6 DC7 2V Siren Volume 110dB List 2 Home Alarm Defense Zone Arm Type Arm Information es Emergency effective effective 24 hours Emergenc
3. setup status use keypad to input 39 then input the number indicating turning on timely arm disarm 1 0 and then input to confirm You will hear a long beep and a voice prompt setting completed The factory default is off Operating method 39 gt 0 1 gt Q turn off the function of timely arm disarm 1 turn on the function of timely arm disarm For example turn on the function of timely arm disarm Operating method 39 gt 1 gt 12 Time setting for Out Arm Delay Default 60sec In setup state input the command 44 XX XX indicates the delay time of out arm XX 01 99 1 sec to 99 sec Note The setting is effective only with the keypad operation The operation by remote controller or SMS is immediate arm without delay 10 13 Time Setting for Alarm Delay Default 40sec In setup state input the command 45 XX XX indicates the delay time of out arm XX 01 99 1 sec to 99 sec Note The setting is effective only when a zone is set as Alarm Delay Zone Note Before the system enters arm or alarm status It will emit a Di sound per second 14 Alarm Number Setting In setup state input 51 56 then input the voice alarm receiving number mobile number or telephone number and then press to confirm The main unit will make a long beep the Signal indicator will flicker once and you will hear setting completed which indicate voice alarm receiving number is set successfully
4. 4 Factory Reset In disarm status use keypad to input 95175308246 and press to confirm all the LED indicators will be on for 2 seconds and you will hear a long beep The main unit gets all its settings cleared and restores to its factory settings successfully Operating method 95175308246 5 Coding of Remote Controller The remote controller has to be code to the alarm_host in order to perform normally In setup state use keypad to input 20 input the remote controller number 1 8 and then press to confirm The main unit emits a long beep and you will hear remote control coding The e indicator is on without flashing press any button on the wireless remote controller the main unit makes a long beep and you will hear coding completed e indicator goes out indicating the remote controller succeeds in coding Operating method 20 gt A gt A indicates 1 8 remote controllers number You can add maximum 8 remote controllers LCD display IT cl WM 6 Delete Remo e Controller The remote controller can t control the main unit after it s deleted In setup state use keypad to input 21 then input the remote controller number 1 8 and then press to confirm The main unit emits a long beep and the Signal indicator flickers once You will hear a voice prompt delete completed Operating method 21 gt A gt A indicates 1 8 remote con
5. MOBILE CALL GSM Alarm System ZC GSM015 User s Manual Profile For a better understanding of this product please read this user manual thoroughly before using it Function Instruction 7 wired and 99 wireless defense zones LCD screen with time clock display Voice prompt for all operations 3 groups of timely arm and disarm Can store 6 phone numbers when alarming system will make alarm call to these numbers automatically Can store 3 SMS numbers when alarming system will send alarming SMS automatically 10 second automatic message recording Built in artificial intelligent digital voice announcer Built in artificial intelligent English message Users can make calls by using keypad on alarm panel just like a telephone One key control function Out Arm Home Arm Remote Arm SOS fire gas door hall window balcony and boundary places alarm Real time delay 24 hours bypass defense zones programming function Wireless coding easy to add additional wireless accessories Remote control Arm Disarm Monitor and Intercom by phone SMS alert for power failure or recovery Built in AAA NI HI rechargeable battery make alarm when power off Comply with CCC safety standard and GB12663 2001 national standard Alarm Host Diagram In order to make the main unit get the wireless signal well for all wireless accessories please put the alarm host at the central place of your defense area Make sure it s aw
6. Operating method XX gt YY YY gt XX indicates the 1 6 alarming user number 51 56 YY YY indicates voice alarm receiving phone number For example set 13811111111 as the first voice call number Operating method 51 gt 13811111111 gt LCD display 4 HEES 15 Delete Phone Number In setup state input 51 56 and then press to confirm the main unit will make a long beep and the Signal indicator will flicker once and you will hear delete completed which indicate the alarming user number is deleted successfully Operating method XX gt XX indicates the 1 6 alarming user number 51 56 For example Delete the third alarming user number from the system LCD display L 11 16 SMS Receiving Number Setting SMS Receiving number means when system is alarming it will only send SMS to this mobile number You can set maximum 3 SMS numbers In setup state input 57 59 then input the SMS receiving number and then press button to confirm The main unit will make a beep the Signal indicator will flicker once and you will hear setting completed which indicate setup successfully Operating method XX gt YY YY gt XX indicates address codes of message receiving numbers from the first group to the third group 57 59 YY YY indicates the SMS receiving number For example setup 13822222222 as the first SMS receiving numb
7. and after 10 seconds countdown recording starts record at 30cm away from the main unit with moderate tone 10 seconds later the main unit will make a beep indicating the recording stops and the recorded voice will replay Operating method 701 gt LCD display L 22 Siren Setting In setup state use keypad to input 75 in the operation of arm disarm by remote control select if the siren sounds or not by 0 1 button and then press to confirm The main unit will emit a long beep and a voice prompt setting completed Operating method 75 gt A gt A indicates 0 Siren off 1 Siren on System default 0 Siren off For example set siren on when arm disarm Operating method 75 gt 1 gt LCD display EE 23 Siren Setting in Emergency Help mode In setup state use keypad to input 76 and then 1 0 finally press to confirm The main unit will make a long beep and a voice prompt setting completed Operating method 76 A A indicates 0 siren off in Emergency Help mode 14 1 siren on in Emergency Help mode System default 0 siren off Operation Instructions 1 System status There are 4 status as following 1 Arm defense zone 1 99 will alarm when detectors are triggered 2 Home Arm in arm status the defense zone which is set as Home Arm will alarm when detectors are triggered 3 Disarm defense zone 1 99 will not alarm
8. ay from large metal objects and household appliances which may cause high frequency interference as well as barriers such as reinforced concrete wall or fire door etc Alarm Panel front schematic diagram E Signal y ser e Alorm MOBILE CALL ALARM Functions indicator Defense Zone Indicator 4 5 a Q s s s D 9 bolsa decoa wales Ee nies Emergency 0 ee ee Call out Alarm Panel back schematic diagram n OE SIM Card Socket Power Switch DC 12V Input Lead wire Slot oe Wire Connector PCB Panel d Battery Case o J Wired terminal block I Hiel B wua IB lIalwl Belt L D m m z Z N zZ z o r r o N o N o N N N N N T T T i f f 15 Positive of Siren red cable Note 1 LB and LB are to connect external speaker If you think the internal speaker is not loud enough please contact us for professional speakers 2 Connect one cable of the wired sensor to GND and the other to ZAIZ2 Z3 Z7T 3 Please pay attention to the siren connection Do not mix the two cables together when connecting Otherwise it will damage the transistor in the main panel LCD display Banke d L St S a B Y CA Status Indicator 1 E Clock Defenge zone Py SG Le ES Fire Alarm Gas Leakage Window Alarm Door Alarm SOS Hall Alarm Balcony Alarm Bounda
9. e 2 digits of the present date DD indicates the 2 digits of the present hour EE indicates the 2 digits of the present minute FF indicates the 2 digits of the present second For example set the time as 15 35 40 Oct Ist 2009 Operating method 32 gt 09 gt 10 gt 01 gt 15 gt 35 gt 40 gt 11 Timing Settings 1 Timely Arm In setup status use keypad to input 33 35 then input the hour AA and minute BB of the time you want to set to arm and finally input to confirm You will hear a long beep and a voice prompt setting completed Operating method XX gt AA gt BB gt XX indicates the address code 33 34 35 of the timely arming AA indicates the hour of the setting time BB indicates the minute of the setting time For example set the arm time as 45 10pm Operating method 33 gt 22 gt 45 gt LCD display 2 Timely Disarm In setup status use keypad to input 36 38 then input the hour AA and minute BB of the time you want to set to disarm and finally input to confirm You will hear a long beep and a voice prompt setting completed Operating method XX gt AA gt BB gt XX indicates the address code 36 37 38 of the timely disarming AA indicates the hour of the setting time BB indicates the minute of the setting time For example set the arm time as 55 7pm Operating method 33 gt 22 gt 45 gt 3 Timing Control In
10. e prompt setting completed Operating method 30 gt XXXX gt XXXX indicates the new 4 digit password For example change the system password to 1012 Operating method 30 gt 1012 gt LCD display E pr 2 Change Program Password Program password is the password you should input in order to setu the system In setup status use keypad to input 31 then input the 4 digit new password and then press to confirm The main unit will make a long beep and you will hear a voice prompt setting completed Operating method 31 gt XXXX gt XXXX indicates the new 4 digit password For example change the system password to 2846 Operating method 31 gt 2846 gt LCD display ioe eS 4 Cem a a aes E Note the operation password and the programming password can not be se 10 Clock Setting In setup status use keypad to input 32 then input the last 2 digits AA of the present year the two digits BB of the month the two digits CC of the date the two digits DD of the hour 24 hour system the two digits EE of the minute the two digits FF of the second and finally enter to confirm You will hear a long beep and a voice prompt setting completed Operating method 32 gt AA gt BB gt CC gt DD gt EE gt FF gt AA indicates the last 2 digits of the present year BB indicates the 2 digits of the present month CC indicates th
11. er Operating method 57 gt 138222222 gt 17 Delete SMS Receiving Number In setup state use keypad to input 57 59 and then press button to confirm The main unit will make a beep the Signal indicator will flicker once and you will hear delete completed which indicate SMS number is deleted successfully Operating method XX gt XX indicates address codes of message receiving numbers from the first group to the third group 57 59 For example delete the first SMS user number from the system Operating method 57 gt 18 SMS Notification for Arm Disarm Default OFF In setup state input the command 77 1 0 1 NO 0 OFF After starting this function the system can send SMS to three SMS receiving numbers 57 59 as mentioned above when the system enters arm disarm status through wireless remote controllers or its keypad opeation 12 19 Defense Zone Programming If you want to change the alarm attribute of defense zone such as turn off the siren when system alarms you can do it by defense zone programming In setup state first input 60 then the defense zone number 01 99 then input defense zone type 1 4 then input defense zone location number 1 8 and then select siren on off 0 1 at last press to confirm You will hear the main unit emit a long beep and a voice prompt setting completed Operating method 60 gt AA gt B gt C gt D gt AA de
12. fense zone number 01 99 means zone 1 to zone 99 B defense zone type 1 real time defense zone 2 40 seconds delay defense zone 3 24 hours defense zone 4 bypass defense zone C defense zone location 1 SOS Alarm 2 Fire Alarm 3 Gas Leak Alarm 4 Door Alarm 5 Hall Alarm 6 Window Alarm 7 Balcony Alarm 8 Boundary Alarm D siren ON OFF 0 OFF 1 ON For example set defense zone 12 to be 24 hour fire alarm and siren on Operating method 60 12 gt 3 gt 2 gt 1 gt 20 Home Arm Defense Zone Setting If you want some detectors work and some do not you can use Home Arm function In setup state use keypad to input 61 then choose the corresponding defense zone number 01 99 then choose Home Arm and then choose whether alarm 0 1 button and finally press to confirm The main unit will make a long beep and a voice prompt setting completed Operating method 61 gt XX gt A gt XX indicates 01 99 is defense zone 1 to defense zone 99 A indicates 0 Home arm but not alarm 1 Home arm and alarm For example set defense zone 11 to be Home arm and alarm Operating method 61 gt 11 gt 1 gt 13 For example set defense zone 12 as Home arm but not alarm Operating method 61 gt 12 gt 0 gt 21 Voice Recording In setup state use keypad to input 701 and then press to confirm The main unit will emit a beep and the C indicator is on
13. may cause improper warning then you shall select Arm at Home let just part of the detectors work and disable the other parts Main Unit Operation Press At Home button on keypad Remote Control Operation Press r button on remote controller LCD display 5 Disarm It means to stop the alarm when the main unit sounds the alarm or make the alarm system in the state of non warning After disarming even if you trigger the detector the main unit would not sound alarm excluding 24 hour defense areas Use keypad to input system password then press button Out Home or At Home lights will be off It means set system disarm successfully Remote Control Operation Press CR button on remote controller Main Unit Operation input password LCD display You can also set disarm by SMS remotely The SMS command is Operation Password Default 1234 2 After the setting the main unit makes 16 6 Answer Alarm Call When the main unit sounds alarm it will dial the preset numbers If no one answers the call the system will call the next user number automatically The system will call each preset numbers for 3 times in order If you answer the call you will hear the pre record voice You can set system via your telephone or mobile phone keypad If you hang up directly without answering the call the system will call each preset number for 3 times circularly Press Read the alarm information
14. ry Alarm Function Settings 1 Initialization Please insert SIM card and plug in power adaptor and then power on the system all the LED lights will be on for 2 seconds and you will hear a long beep the system comes into initialization After the time clock displays on the LCD screen the SGM starts flashing and the main unit starts to detect the GSM network until a long beep Then the SGM indicator goes out indicating the system comes into disarm status Finally turn on the backup battery switch 2 Enter Settings In the state of disarm input 4 digit password by the keypad on the main unit and press button to confirm You will hear a voice prompt please enter instruction At the same time SET indicator is on without flashing and 0000 displays on the screen indicating the system enters setting status You can perform different settings repeatedly as long as the system keeps in setting status The system will exit setting mode and return to disarm status if you don t press any keypad button for 40 seconds Note In setting status press can delete the numbers input The system default password is 8888 Operating method XXXX gt X indicates the new 4 digit password wl LCD display 100 og 3 Exit Settings Press and buttons the main unit emits a long beep and exits settings The SET indicator goes out and the system returns to disarm State Operating method gt
15. tatus you can use the main unit to make any call just like a land line telephone Dial telephone number on keypad press 8 button the main unit will make a beep and the Signal indicator will be flashing After the call press CH button again the main unit will be in disarm Status Alarming Record Checking In disarm state input 0 then the main unit will make a long beep and enters the state of alarm record checking After displaying the alarm and defense zone number indicator the LCD screen will display the exact alarming time of this defense zone Press 2 you can upturn to check the previous alarming record press 8 downturn to check and press to exit checking For example the 5lst defense zone the 7th alarming alarming time 12 00 August Ist 2008 LCE display for one second eh Ss E D ion bech o Lei E kel D lt os gt o kel 3 ga T z Q an GSM Signal Checking Before installing the main unit you should check the signal of the installing place in order to ensure the unit can perform well In setup 18 state input 81 gt the main unit will make a long beep and display 00 XX XX indicates the intensity of the signal And the intensity should be within the range of 07 31 if it s less than 07 you should change place For example if the signal intensity is 12 it will display as C E Ke eege eege Gd Maintenance 10 System
16. trollers number E Coding of Defense Zone Wireless detectors have to be coded to the main unit in order to trigger it alarm In setup state use keypad to input 23 input the defense zone number you want to code 01 99 and then input to confirm The main unit emits a long beep and the corresponding defense zone is displayed on the screen You will hear a voice prompt detector coding Then trigger a wireless detector to emit a wireless signal after receiving the signal the main unit makes a long beep and you will hear coding completed the ti indicator goes out at the same time Operating method 23 gt XX gt XX indicates 01 99 defense zones number LCD display 8 Delete Defense Zone The wireless detector can t control the main unit after it s deleted In setup state use keypad to input 24 then input the defense zone number you want to delete 01 99 and then input to confirm The 7 main unit emits a long beep and the defense zone indicator flickers once You will hear a voice prompt delete completed Operating method 24 gt XX gt XX indicates 01 99 defense zones number 9 Change Password 1 Change Operation Password Operation password is the password used to disarm or remote control In setup status use keypad to input 30 then input the 4 digit new password and then press to confirm The main unit will make a long beep and you will hear a voic
17. when detector triggered except 24 hours defense zone 4 System setup status In this status all defense zones will not alarm when detectors are triggered 2 Remote Controller Operation Users can use remote controller to set system as Out Arm Home Arm Emergency Alarm Real time Disarm and etc Out Arm Press button Disarm Press ew button Home Arm Press 7 button Emergency Alarm Press A button system will alarm at once 3 Out Arm It means to guard all around your house while everyone is going out all the detectors of the host are always working when the detector is triggered by detecting source anti theft fire prevention gas leak etc the alarm system will sound the alarm Press Out Home button on keypad system will make a beep per second and totally 60 beeps The OUT ARM indicator will be on without flashing It means Out Arm is set successfully Arm Operation Press Out Home button the system will enter arm status 60 seconds later LCD display ie eoa You can also set out arm by SMS remotely The SMS command is 15 Operation Password Default 1234 1 After the setting the main unit makes a Di Sound ARM LED is on and you will receive a SMS System armed 4 Home Arm It means for the safety while somebody is at home you need to enable the peripheral door window balcony and boundary detectors of the alarm system while prevent from triggering the indoor detectors which
18. y alarm no button Wired defense effective invalid real time Emergency alarm yes zone 96 99 20 Components list Main panel 1 pc Remote controller 2 pcs PIR sensor 1 pc Door sensor 1 pc Power adapter 1 pc User manual 1 pc Typical house configuration x va External Sirens ae Remote control Garage Smoke Detector FIR Mouvement Detectors pp 21 22