Home
HUDAS TC_v2.0C
Contents
1. 1 2 Applications e Temperature measurement e Industrial ON OFF control Industrial and Lab automation 2 Copyright 2009 CyberResearch Inc CyberResearch Data Acquisition HUDAS TC 1 3 Installation Guide Before you install your HUDAS TC module please make sure you have the following necessary components HUDAS TC DAS Module HUDAS TC User Manual e Shielded USB 2 0 cable 1 8 m e Driver software CyberResearch DLL drivers included in the companion CD ROM e Personal computer or workstation with a USB port running Windows 2000 or XP Some application software is also available for enhanced operation HUDAS TC works with ActiveDAQ ActiveDAQ Pro and other third party software packages After you have the necessary components and optional accessories for enhanced operation of your HUDAS TC module you can then begin the installation procedure Figure 1 1 on the next page provides a concise flow chart to give a broad picture of the software and hardware installa tion procedures CyberResearch Inc 25 Business Park Drive P 203 643 5000 F 203 643 5001 Branford CT USA www cyberresearch com HUDAS TC CyberResearch Data Acguisition Install Driver from CD ROM Install hardware Use driver utility to configure hardware Use test utility to test hardware Read examples amp driver manual Start to write your own application Figure 1 1 Installation Flow Chart S
2. Data Acguisition HUDAS TC USB Thermocouple DAS Module 8 Channels of 16 bit A D USER S MANUAL VER 2 0C Jul 09 No part of this manual may be reproduced without permission CyberResearch Inc www cyberresearch com 25 Business Park Dr Branford CT 06405 USA 203 643 5000 9 A M to 5 P M EST FAX 203 643 5001 CyberResearch Data Acguisition HUDAS TC Copyright 2009 All Rights Reserved July 25 2009 The information in this document is subject to change without prior notice in order to improve reliability design and function and does not represent a commitment on the part of CyberResearch Inc In no event will CyberResearch Inc be liable for direct indirect special incidental or consequential damages arising out of the use of or inability to use the product or documentation even if advised of the possibility of such damages This document contains proprietary information protected by copyright All rights are reserved No part of this manual may be reproduced by any mechanical electronic or other means in any form without prior written permission of CyberResearch Inc Trademarks CyberResearch and HUDAS TC are trademarks of CyberResearch Inc Other product names mentioned herein are used for identification purposes only and may be trademarks and or registered trademarks of their respective companies e NOTICE gt CyberResearch Inc does not authorize any CyberResea
3. Signal Reference Direction Description Name IDI lt 0 7 gt ICOM Input Isolated Digital Input Channels ICOM Common Port of IDI Channels IDO lt 0 7 gt OCOM Output Isolated Digital Output Channels OGND Isolated Digital Output Ground OCOM Positive External Power Supply Al lt 0 7 gt Input Analog Input Channels CJC CJC Cold Junction Compensation NC No connected 3 2 3 LED Indicator Status Description The USB Module is equipped with a LED indicator to show the current status of the device When you plug the USB device into the USB port the LED indicator will blink five times and then stay lit to indicate that it is on Please refer to the following table for detailed LED indicator status information Table 3 2 LED Indicator Status Description LED Status Description ON Device ready for work Off Device not ready to work Slow Blinking 5 times Device Initialization Fast Blinking Depends on data transfer speed Device working 28 Copyright 2009 CyberResearch Inc C yberResearch Data Acquisition HUDAS TC 3 2 4 3 2 4 Jumper Setting Description ting for analog input ch5 Table 3 3 Jumper Setting Description Jumper Description Jumper Description JP1 Input mode set JP6 Input mode setting for analog ting for analog input ch6 input chO JP2 Input mode set Jp7 Input mode setting for ana
4. The equipment must be returned postage prepaid Package it securely and insure it You will be charged for parts and labor if the warranty period has expired Returns and RMAs If a CyberResearch product has been diagnosed as being non functional is visibly damaged or must be returned for any other reason please call for an assigned RMA number The RMA number is a key piece of information that lets us track and process returned merchandise with the fastest possible turnaround time PLEASE CALL FOR AN RMA NUMBER Packages returned without an RMA number will be refused In most cases a returned package will be refused at the receiving dock if its contents are not known The RMA number allows us to reference the history of returned products and determine if they are meeting your application s requirements When you call customer service for your RMA number you will be asked to provide information about the product you are returning your address and a contact person at your organization Please make sure that the RMA number is prominently displayed on the outside of the box Thank You CyberResearch Inc 49 25 Business Park Drive P 203 643 5000 F 203 643 5001 Branford CT USA www cyberresearch com HUDAS TC Cyber Research Data Acguisition Intentionally Blank 50 Copyright 2009 CyberResearch Inc CyberResearch Inc 25 Business Park Drive Branford CT 06405 USA P 203 643 5000 F 203 643 5
5. Data Acguisition HUDAS TC Warranty Notice CyberResearch Inc warrants that this eguipment as furnished will be free from defects in material and workmanship for a period of one year from the confirmed date of purchase by the original buyer and that upon written notice of any such defect CyberResearch Inc will at its option repair or replace the defective item under the terms of this warranty subject to the provisions and specific exclusions listed herein This warranty shall not apply to equipment that has been previously repaired or altered outside our plant in any way which may in the judgment of the manufacturer affect its reliability Nor will it apply if the equipment has been used in a manner exceeding or inconsistent with its specifications or if the serial number has been removed CyberResearch Inc does not assume any liability for consequential damages as a result from our products uses and in any event our liability shall not exceed the original selling price of the equipment The equipment warranty shall constitute the sole and exclusive remedy of any Buyer of Seller equipment and the sole and exclusive liability of the Seller its successors or assigns in connection with equipment purchased and in lieu of all other warranties expressed implied or statutory including but not limited to any implied warranty of merchant ability or fitness and all other obligations or liabilities of seller its successors or assigns
6. before attempting to install the Examples and Online Help files CyberResearch MAIN MENU Branford Connecticut USA Fig 2 3 12 Copyright 2009 CyberResearch Inc CyberResearch Data Acquisition HUDAS TC Step 4 Follow the Installers on screen instructions Step 5 When done navigate to C Program Files CyberResearch ADSAPI Manual to access the online HTML manuals Driver chm is the DLL Driver manual CyberResearch Inc 13 25 Business Park Drive P 203 643 5000 F 203 643 5001 Branford CT USA www cyberresearch com HUDAS TC CyberResearch Data Acquisition 2 3 Hardware Installation Note Make sure you have installed the software driver before you install the module please refer to Section 2 2 Driver Installation After the DLL driver installation is completed you can now go on to install the HUDAS TC module in any USB port that supports the USB 2 0 standard on your computer It is suggested that you refer to the com puter s user manual or related documentation if you have any doubts Please follow the steps below to install the module on your system Step 1 Touch the metal part on the surface of your computer to neutralize the static electricity that might be in your body Step 2 Plug your USB module into the selected USB port Hold the mod ule only by its edges Plug the module firmly into place Use of excessive force must be avoided otherwise the module might get damaged Note I
7. bus powered Power Consumption 100mA 5V max Temperature Operation 0 60 C 32 140 F refer to IEC 68 2 1 2 Storage 20 70 C 4 158 F Relative Humidity 5 95 RH non condensing refer to IEC 68 2 1 2 38 OCopyright 2009 CyberResearch Inc Function Block APPENDIX CyberResearch Data Acguisition HUDAS TC Appendix B Function Block Switch Microcontroller With EEPROM 16 bit AD Converter USB Control Chip NET2272 0 i 8 ch Isolated Digital Output 8 ch Isolated Digital Input Control and read data by USB bus Copyright 2009 CyberResearch Inc 40 C Appendix Analog Input Calibration HUDAS TC CyberResearch Data Acquisition Appendix C Analog Input Calibration The following steps will guide you through the HUDAS TC analog input channel software calibration Please perform BOTH voltage and current input calibrating procedures to complete the calibration of HUDAS TC s analog input channels C 1 Voltage Input Calibration You need to calibrate only one channel AIO The other channels of HUDAS TC will be calibrated automatically NOTE Please make sure that the JP1 on HUDAS TC is set to voltage input mode before you start voltage input calibrating Step 1 Click the Setup button in the CyberResearch DAQ Device Manager window to launch the HUDAS TC Device Setting window Then
8. click Cali bration to start the calibration process The Calibration Wizard window will pop up 42 Copyright 2009 CyberResearch Inc CyberResearch Data Acguisition HUDAS TC Device Setting Firmware Version 1 1 6 1 ES Identify Board ID jo X Locate Label string 32 characters most Edit Save Fc 0 0 050v vij r v v CE 0 0 015 vij gt Fc 0 0 015 PR r v ui 0 0 015Y Dee Sample Rate 4 p gt jis Hz Cancel Restore CJC Offset Calibration Figure C 1 HUDAS TC Device Setting window Step 2 Select 0 0 015V voltage input range or any and connect the OV voltage source to AIO of HUDAS TC then click Calibrate The information box will show up after the zero range calibration is com pleted Then click OK CyberResearch Inc 43 25 Business Park Drive P 203 643 5000 F 203 643 5001 Branford CT USA www cyberresearch com HUDAS TC CyberResearch Data Acguisition a Calibration Wizard Al Range This wizard will guide you to calibrate Analog lutput Rage Zero range Ca Full range Cali 0 0 015 0 0 050 0 0 100 gt 0 0 500 0 1 0 0 2 5 1 90m Instruction 1 Please connect the OV voltage to the AIO as below aie ry DC Power Suply Calibrate Figure C 2 HUDAS TC Calibration Wizard Information Zero calibration complete Pl
9. driver installation process again You can check the Device Properties to see if your device is running under Full Speed mode USB 1 1 or High Speed mode USB 2 0 See figure 2 3 on the next page CyberResearch Inc 15 25 Business Park Drive P 203 643 5000 F 203 643 5001 Branford CT USA www cyberresearch com HUDAS TC CyberResearch Data Acguisition Device Properties General Driver lL Details oe gt CyberResearch HUDAS TC Device Device type CyberResearch DA amp C USB Device Manufacturer CyberResearch Inc Device status This device is working properly If you are having problems with this device click Troubleshoot to start the troubleshooter Troubleshoot Device usage Use this device enable x Figure 2 3 HUDAS TC Device Speed After your module is properly installed with your system you can now configure your device using the CyberResearch DAQ Device Manager that has itself already been installed on your system during driver setup A com plete device installation procedure should include device setup configu ration and testing The following sections will guide you through the Setup Configuration and Testing of your device 2 4 Device Setup amp Configuration CyberResearch DAQ Device Manager is a utility that allows you to set up config ure and test your devices and later stores your settings in the system reg istry These settings wil
10. tt a A CJC Temperature 25 67 GJC reading Readin rie Channel pis x s Temperature ss Channel reading value Thermocouple type OK Cancel CJC Offset Adjustment Tif 8 AI Calibration Analog input channel calibration function 2 4 3 Gain Code Setting Configure the AI analog input channel s input voltage current range by setting the corresponding GainCode of the device The configuration for voltage and current is differentiated by the value of GainCode The value of current GainCode is greater than 0x8000 CyberResearch Inc 19 25 Business Park Drive P 203 643 5000 F 203 643 5001 Branford CT USA www cyberresearch com HUDAS TC CyberResearch Data Acquisition Table 2 1 Gain Code Gain Code Hex Type Range 0x08 Voltage 0 15mV OKOA Voltage 0 50mV 0x0B Voltage 0 100mV Ox0D Voltage 0 500mV Ox0E Voltage 0 1 0V Ox0F Voltage 0 2 5V 0x8000 Current 0 20mA 0x8001 Current 4 20mA 2 5 Device Testing Following the Setup and Configuration procedures to the last step described in the previous section you can now proceed to test the device by clicking the Test Button in the 7 0 Device Installation dialog window In the Device Test dialog window you are free to test various functions of HUDAS TC on the Analog input Analog output Digital input Digital out put or Counter tabs 2 5 1 Testing Analog Input Function Click the Analog In
11. 001 www cyberresearch com
12. 09 CyberResearch Inc CyberResearch Data Acquisition HUDAS TC 3 3 Analog Input Connections The differential input channels operate with two signal wires for each channel and the voltage difference between both signal wires is mea sured There are 8 analog input channels available on HUDAS TC Internal External Figure 3 2 Differential Input Channel Connection 3 4 Isolated Digital Input Connections HUDAS TC has 8 isolated digital input channels designated IDIO IDI7 Each of isolated digital input channel accepts 5 30 VDC voltage inputs and accept bi directional input It means that you can apply positive or negative voltage to an isolated input pin IDI All 8 input channels share one common pin Figure 3 3 shows how to connect an external input source to one of the module s isolated input channels CyberResearch Inc 3 25 Business Park Drive P 203 643 5000 F 203 643 5001 Branford CT USA www cyberresearch com HUDAS TC CyberResearch Data Acquisition IDIO IDI7 External Internal ICOM DI0 DI7 Figure 3 3 Digital Input Channel Connections 3 5 Isolated Digital Output Connections HUDAS TC has 8 isolated digital output channels designated IDO0 IDO7 Each of isolated output channels comes equipped with a Darlington tran sistor All 8 output channels share common collectors and integral sup pression diodes for inductive loads Figure 3 4 shows how to connect an external output lo
13. Field Wiring Considerations ww mwwmmwee 33 Appendix A Specifications s000s0s00000000000000000 30 AE Anal g Aa 36 Table A 1 Analog Input w wwwwmmmmenmamimmmwww 36 A 2 Accuracy for Thermocouple wwwmmmmmmeo 36 Table A 2 Accuracy for Thermocouple 36 A 3 Isolated Digital Input 37 Table A 3 Isolated Digital Input lt lt lt v 37 A 4 Isolated Digital Output w wwwwmmeememmemewo 37 Table A 4 Isolated Digital Output lt lt lt lt lt v 37 AS CE E ya MASAA HASA SA KAA E EAEE 38 Table AGE ai 38 Appendix B Appendix C C 1 C 2 Function Block s s0es00000000 40 Analog Input Calibration 42 Voltage Input Calibration 42 Figure C 1 HUDAS TC Device Setting window 43 Figure C 2 HUDAS TC Calibration Wizard 44 Figure C 3 Zero range calibration complete 44 Figure C 4 Full range calibration lt 45 Figure C 5 Calibration Complete lt lt ve 45 Current Input CalibratioN w w w mmee 46 Figure C 6 Select the current input range setting 46 vi Copyright 2009 CyberResearch Inc C
14. HAPTER Introduction This chapter will provide information on the features of the DAS module a guick start guide for installation and some brief information on software and accessories for the HUDAS TC Module Sections include e Features e Applications e Installation Guide e Software Overview e Device Driver e Programming Roadmap HUDAS TC CyberResearch Data Acquisition Chapter 1 Introduction HUDAS TC offers 8 thermocouple inputs with 16 bit resolution up to 0 1 input range accuracy or 4 20 mA inputs Reliable and rugged enough for industrial applications yet inexpensive enough for home projects HUDAS TC 1s the perfect way to add measurement and control capability to any USB capable computer The HUDAS TC is fully USB plug and play and easy to use It obtains all required power from the USB port so no external power connection is ever required 1 1 Features HUDAS TC has the most requested measurement amp control functions e 8 differential thermocouple input channels 16 bits resolution Software configurable for thermocouple low level voltage or current inputs Wiring burned out detectable function Thermo mode 2 500 Vdc isolation Watchdog Timer Supports 0 20 amp 4 20mA current inputs Bus powered Device status LED indicator Removable on module wiring terminal USB 2 0 Support Hot swappable Note For detailed specifications of HUDAS TC please refer to Appendix A Specifications
15. a tion on how to connect input and output signals to the HUDAS TC via the I O connectors Sections include e Overview e I O Connectors e Analog Input Connections e Analog Output Connections e Trigger Source Connections e Field Wiring Considerations HUDAS TC CyberResearch Data Acquisition Chapter 3 Signal Connections 3 1 Overview Maintaining good signal connections is one of the most important factors in ensuring that your application system is sending and receiving data correctly A good signal connection can avoid unnecessary and costly damage to your PC and other hardware devices 3 2 1 0 Connectors HUDAS TC is equipped with plug in screw terminal connectors that facili tate connection to the module without terminal boards or cables 3 2 1 Pin Assignment Figure 3 1 on next page shows the pin assignments for the five 10 pin I O connectors on HUDAS TC 26 Copyright 2009 CyberResearch Inc CyberResearch Data Acguisition HUDAS TC Ldr Sdf Edf bdo oq payeos 43 8 8dr 94f pdf ede gt 2 mey 3 3 Q Q S D T Z Ja payeos 42 8 Figure 3 1 1 0 Connector Pin Assignment CyberResearch Inc 27 25 Business Park Drive P 203 643 5000 F 203 643 5001 Branford CT USA www cyberresearch com HUDAS TC Cyber Research Data Acquisition 3 2 2 1 0 Connector Signal Description Table 3 1 1 0 Connector Signal Description
16. ad to the module s isolated outputs Note 1 It is necessary to connect the OCOM pin with a external power source for wiring 2 _Ifan external voltage 5 30 VDC is applied to an isolated output channel while it is being used as an output channel the current willflow from the external voltage source to the card Please take care thatthe cur rent through each IDO pin not exceed 200 mA 32 Copyright 2009 CyberResearch Inc CyberResearch Data Acquisition HUDAS TC Internal External Figure 3 4 Isolated Digital Output Channel Connections 3 6 Field Wiring Considerations When you use HUDAS TC to acquire data from outside noises in the environment might significantly affect the accuracy of your measure ments if due cautions are not taken The following measures will be helpful to reduce possible interference running signal wires between signal sources and the HUDAS TC The signal cables must be kept away from strong electromagnetic sources such as power lines large electric motors circuit breakers or welding machines since they may cause strong electromagnetic inter ference Keep the analog signal cables away from any video monitor since it can significantly affect a data acquisition system If the cable travels through an area with significant electromagnetic interference you should adopt individually shielded twisted pair wires as the analog input cable This type of cable has its signal wires twi
17. back switch or jumper settings and possibly change settings before reinstalling the modules 3 Have a volt meter handy to take measurements of the signals you are trying to measure as well as the signals on the board module or power supply 4 Isolate problem areas that are not working as you expected 5 Have the source code to the program you are having trouble with available so that preceding and prerequisite modes can be referenced and discussed 6 Have the manual at hand Also have the product s utility disks and any other relevant disks nearby so programs and version numbers can be checked Preparation will facilitate the diagnosis procedure save you time and avoid repeated calls Here are a few preliminary actions you can take before you call which may solve some of the more common problems 1 Check the PC bus power and any power supply signals 2 Check the voltage level of the signal between SIGNAL HIGH and SIGNAL LOW or SIGNAL and SIGNAL It CANNOT exceed the full scale range of the board 3 Check the other boards in your PC or modules on the network for address and interrupt conflicts 4 Refer to the example programs as a baseline for comparing code CyberResearch Inc 47 25 Business Park Drive P 203 643 5000 F 203 643 5001 Branford CT USA www cyberresearch com HUDAS TC Cyber Research Data Acguisition Intentionally Blank 48 Copyright 2009 CyberResearch Inc CyberResearch
18. d to perform a certain task for the application When a function returns a code that is not zero it means the function has failed to perform its designated func tion To troubleshoot the Device Drivers error you can pass the error code to DRV_GetErrorMessage function to return the error message Alternatively you can refer to the Device Drivers Error Codes Appendix in the Device Drivers Manual for a detailed listing of Error Codes Error IDs and the Error Messages CyberResearch Inc 7 25 Business Park Drive P 203 643 5000 F 203 643 5001 Branford CT USA www cyberresearch com HUDAS TC CyberResearch Data Acquisition 8 Copyright 2009 CyberResearch Inc CHAPTER Installation This chapter has a package item check list proper instructions about unpack ing and step by step procedures for both driver and USB installation Sections include e Unpacking e Driver Installation e Hardware Installation e Device Setup amp Configuration e Device Testing e Hardware Uninstallation HUDAS TC CyberResearch Data Acquisition Chapter 2 Installation This chapter gives users a package item checklist proper instructions about unpacking and step by step procedures for both driver and card installation 2 1 Unpacking After receiving your HUDAS TC package please inspect its contents first The package should contain the following items e HUDAS TC card e Companion CD ROM DLL driver included e U
19. ease start the Full range calibration by following the Instruction Figure C 3 Zero range calibration complete Step 3 Please start the full range calibration by connecting to the full range voltage source and click Calibrate You will see a dialog box and click OK to finish the calibration process 44 Copyright 2009 CyberResearch Inc C yberResearch Data Acquisition HUDAS TC Calibration Wizard Al Range This wizard will guide you to calibrate Analog lutput Range Zero range Ca Full range Cali 0 0 015 OK 0 0 050V 0 0 100V 0 0 500V 0 1 0V 0 2 5V N I Instruction 2 Please connect the Full range voltage to the AID as below Full range ah DC Power Suply Figure C 4 Full range calibration Finish Calibration Finished Figure C 5 Calibration Complete Step 4 Please repeat the procedures above to complete the other input ranges 0 0 050V 0 0 100V 0 0 500V 0 1 0V 0 2 5V calibration CyberResearch Inc 45 25 Business Park Drive P 203 643 5000 F 203 643 5001 Branford CT USA www cyberresearch com HUDAS TC C 2 Current Input Calibration You need to calibrate only one channel AIO The other channels of HUDAS TC will be calibrated automatically NOTE Please make sure that the JP1 on HUDAS TC 1s set to current input mode before you start voltage input calibrating Step 1 Please follow the procedures of voltage input ca
20. ee 2 21 Programming Ezamples and Online Manual Installation 4 OCopyright 2009 CyberResearch Inc CyberResearch Data Acquisition HUDAS TC 1 4 Software Overview CyberResearch offers a rich set of DLL drivers third party driver support and application software to help fully exploit the functions of your HUDAS TC module e Device Drivers on the companion CD ROM e LabVIEW driver e CyberResearch ActiveDAQ 1 4 1 Programming Choices for DA amp C Module You may use CyberResearch application software like CyberResearch Device Drivers On the other hand advanced users are allowed to use register level programming as another option although this is not recommended due to its laborious and time consuming nature 1 4 2 Device Drivers The CyberResearch Device Drivers software is included on the companion CD ROM CyberResearch s Device Drivers features a complete I O function library to help boost your application performance The CyberResearch Device Drivers for Windows 2000 XP works seamlessly with develop ment tools such as Visual C Visual Basic Inprise C Builder and Inprise Delphi CyberResearch Inc 25 Business Park Drive P 203 643 5000 F 203 643 5001 Branford CT USA www cyberresearch com HUDAS TC CyberResearch Data Acquisition 1 5 Device Driver Programming Roadmap This section will provide a roadmap to demonstrate how to build an appli cation from scratch using CyberResearch Device D
21. elsewhere 2 2 Driver Installation We recommend you to install the driver before you install the card into your system since this will guarantee a smooth installation process The 32 bit DLL driver Setup program for the HUDAS TC card is included on the companion CD ROM that is shipped with your DAS card package Please follow the steps below to install the driversoftware Step 1 Insert the companion CD ROM into your CD ROM drive Step 2 The Setup program will be launched automatically if you have the autoplay function enabled on your system When the Setup Program is launched you ll see the following Setup Screen 10 Copyright 2009 CyberResearch Inc CyberResearch Data Acguisition HUDAS TC H Series V1 1 INSTALL DRIVERS kT Data Acquisition Drivers VIEW MANUALS DATASHEETS 2 Gains OUR WEBSITE z BROWSE CONTENTS CONTACT US gt CyberResearch Branford Connecticut USA Fig 2 1 Note e Ifthe autoplay function is not enabled on your computer use Windows Explorer or Windows Run command to execute SETUP EXE on the companion CD ROM Step 3 Select the nstall Drivers option Step 4 Select the DLL Drivers option Step 5 Select HUDAS TC Step 6 Just follow the installation instructions step by step to complete your DLL driver setup For further information on driver related issues an online version of the DLL Driver Manual Driver chm is available See the
22. ictable damages to your device or your system Step1 Close the applications of the USB module ex CyberResearch DAQ Device Manager Step2 Right click the Unplug or Eject Hardware icon on your task bar CyberResearch Inc 2 25 Business Park Drive P 203 643 5000 F 203 643 5001 Branford CT USA www cyberresearch com HUDAS TC CyberResearch Data Acguisition 2 Safely Remove Hardware Select the device you want to unplug or eject and then click Stop When Windows notifies you that it is safe to do so unplug the device from your computer Hardware devices Advantech USB4718 Device at Location 0 C Display device components Close Figure 2 11 Unplug or Eject Hardware Dialog Step3 Select HUDAS TC Device and press the Stop Button Stop a Hardware device Confirm devices to be stopped Choose OK to continue Windows will attempt to stop the following devices After the devices are stopped they may be removed safely amp HUDAS TC Device Figure 2 12 Stop a Hardware device dialog box Step4 Unplug your USB device from the USB port Note Please make sure that you have closed the appli cation programs before unplugging the USB device otherwise some unexpected system errors or damages may happen 24 Copyright 2009 CyberResearch Inc CHAPTER Signal Connections This chapter provides useful inform
23. igital output Counter Port No Bit 7 4 3 0 1 II 9009 F Pun Low Change device Exit Figure 2 8 Digital Input Tab Device Test Dialog 2 5 4 Testing Digital Output Function Click the Digital Output tab to bring up the Digital Output test panel as shown below By pressing the buttons on each tab you can easily set each digital output channel as high or low for the corresponding port CyberResearch Device Test HUDAS TC BoardiD 1 Pex Dial output Port No Bit 7 4 Hex ses BEEBE St on orto _ Ev Change device Exit Figure 2 9 Digital Output Tab Device Test Dialog 22 Copyright 2009 CyberResearch Inc CyberResearch Data Acquisition HUDAS TC 2 5 5 Testing Counter Function Unsupported on this module CyberResearch Device Test HUDAS TC BoardID 1 gog Analog input Analog output Digital input Digital output Counter Function not supported Change device Exit Figure 2 10 Counter Tab Testing Unsupported Only after your module device is properly set up configured and tested can the device installation procedure be considered complete After the device installation procedure is completed you can safely proceed to the next chapter Signal Connections 2 6 Hardware Uninstallation Though the CyberResearch USB modules are hot swappable we still recom mend you to follow the hardware un installation procedure to avoid any unpred
24. l Input Tab Device Test Dialog 22 2 5 4 Testing Digital Output Function lt w wmww 22 Figure 2 9 Digital Output Tab Device Test Dialog 22 2 5 5 Testing Counter Function sir 23 Figure 2 10 Counter Tab Testing Unsupported 23 2 6 Hardware Uninstallation w w mmmeemmeea 23 Figure 2 11 Unplug or Eject Hardware Dialog 24 Figure 2 12 Stop a Hardware device dialog box 24 Chapter 3 Signal Connections see 20 Becks ANI Wenen E E ET EE E a EEEE 26 3 2 PO COOL KIA WAWA SNO MAKA SANAA UANI WAA ZA os ce te aea de 26 3 2 1 Pin Assignment kaa Mia 26 CyberResearch Inc 25 Business Park Drive Branford CT USA P 203 643 5000 F 203 643 5001 www cyberresearch com HUDAS TC CyberResearch Data Acquisition Figure 3 1 1 0 Connector Pin Assignment 27 3 2 2 I O Connector Signal Description ssessssssesesseseesesees 28 Table 3 1 1 0 Connector Signal Description 28 3 2 3 LED Indicator Status Description lt v w wev 28 Table 3 2 LED Indicator Status Description 28 3 3 Analog Input Connections 31 Figure 3 2 Single Ended Input Channel Connection 31 3 4 Isolated Digital Input Connections 31 Figure 3 3 Analog Output Channel Connections 32 3 5 Isolated Digital Output Connections 32 3 6
25. l be used when you call the APIs of CyberResearch 32 bit DLL drivers 16 Copyright 2009 CyberResearch Inc C yberResearch Data Acquisition HUDAS TC 2 4 1 Setting Up the Device Step 1 To complete the device setup and configuration procedures you must first install the device along with its driver Please refer to the pre vious section of Chapter 2 for detailed installation instructions Step2 You can view the device s already installed on your system if any in the Installed Devices list box If you haven t installed any devices you might see a blank list DAQ Device Manager DAQ Device Manager Installed Devices BR My Computer ce Test Remove Close Supported Devices CyberResearch HDAS 1612D4 lt CyberResearch HDAC 3214 About 2 CyberResearch HDIO 24L 3 CyberResearch HDI 128 2 CyberResearch HDO 128 Import Export Figure 2 4 Device Manager Dialog Box Note If you have properly installed the device driver but still cant find it in CyberResearch Device Manager please close the CyberResearch Device Manager and restart it 2 4 2 Configuring the Device Step 3 Click Setup button and you will see the Device Setting dialog box as follow On the Device Setting dialog box you can specify the BoardID of the device and perform the AI calibration function for the AI channels Locate will blink the on module LED till you release the bot tom so
26. libration but select the current input range setting in Calibration Wizard CyberResearch Data Acquisition Calibration Wizard Al Range This wizard will guide you to calibrate Analog lutput Ful range Cai JA Instruction 1 Please connect the OV voltage to the AID as below wv d DC Power Suply AIO Calibrate Figure C 6 Select the current input range setting Step 2 Please perform the zero range calibration connect to a OmA current source and the full range calibration connect to a 20mA cur rent source as well 46 Copyright 2009 CyberResearch Inc CyberResearch Data Acguisition HUDAS TC Product Service Diagnosis and Debug CyberResearch Inc maintains technical support lines staffed by experienced Applications Engineers and Technicians There is no charge to call and we will return your call promptly if it is received while our lines are busy Most problems encountered with data acquisition products can be solved over the phone Signal connections and programming are the two most common sources of difficulty CyberResearch support personnel can help you solve these problems especially if you are prepared for the call To ensure your call s overall success and expediency 1 Have the phone close to the PC so you can conveniently and quickly take action that the Applications Engineer might suggest 2 Be prepared to open your PC remove boards report
27. log ting for analog input ch3 input ch4 JP3 Input mode set ypg Input mode setting for analog ting for analog input ch7 input ch1 JP4 Input mode set JP13 Watchdog timer setting JP5 Input mode set ting for analog input ch2 JP1 JP8 Input Mode Setting for Analog Input Channels The analog input mode of every AI channel on HUDAS TC can be set by JP1 JP8 separately to measure the voltage sources or the current sources Inappropriate setting of the jumpers can cause unpredictable errors or malfunction of HUDAS TC Jumper Z Setting Oll O Description Set the channel to voltage Set the channel to input mode Default setting current input mode CyberResearch Inc 25 Business Park Drive Branford CT USA P 203 643 5000 F 203 643 5001 www cyberresearch com HUDAS TC CyberResearch Data Acquisition JP13 Watchdog Timer Setting The watchdog timer supervisory function will automatically reset HUDAS TC in the event of system failure JP13 on HUDAS TC can enable dis able watchdog timer function or reset module manually Jumper Setting O I Description Enable watchdog timer Disable watchdog timer function Default setting function How to Reset HUDAS TC Manually Plug the jumper to JP13 pin2 3 and then remove it HUDAS TC will reset 1 O Note Users may restart the application programs after HUDAS TC is reset 30 Copyright 20
28. n case you installed the module without installing the DLL driver first Windows 2000 XP will recog nize your module as an unknown device after reboot and will prompt you to provide necessary driver You should ignore the prompting messages just click the Cancel button and set up the driver according to the steps described in Section 2 2 Driver Installation 14 Copyright 2009 CyberResearch Inc C yberResearch Data Acquisition HUDAS TC Device Manager Jo File Action View Help e amp amp DARC USB Device ena CyberResearch HUDAS TC Device w Batteries M Computer Disk drives 3 Display adapters 2 DVD CD ROM drives Floppy disk controllers a Human Interface Devices IDE ATA ATAPI controllers S IEEE 1394 Bus host controllers i Infrared devices 5 gt Keyboards 3 Mice and other pointing devices Modems E Monitors E9 Network adapters PCMCIA adapters ay Ports COM amp LPT Processors Figure 2 2 Device Manager Screen Note If your module is properly installed you should see the device name of your module listed on the Device Manager tab If you see your device name listed but marked with an exclamation sign it means your module has not been correctly installed In this case remove the mod ule from Device Manager by selecting its device name and press the Remove button Then go through the
29. next section for installation prior to attempting to locate this and other online manuals CyberResearch Inc 11 25 Business Park Drive P 203 643 5000 F 203 643 5001 Branford CT USA www cyberresearch com HUDAS TC CyberResearch Data Acguisition 2 21 Programming Examples amp Online Manual Installation CyberResearch recommends installing the examples and online manuals after installing the drivers The online manuals provide extremely detailed software programming information and some relevant hardware installation procedures To install the online manuals and programming examples Step 1 Let CD autorun Step 2 Click Install Drivers _ H Series V1 1 i Data Acquisition Drivers BWO VIEW MANUALS lt DATASHEETS a NIEW OUR WEBSITE DA a GI CONTENTS CONTACT US gt CyberResearch Branford Connecticut USA Fig 2 2 Step 3 Click Examples Manuals ae me INSTALL DRIVERS DLL DRIVERS CT AA 1 SW DEVICE MANAGER Please click the button to install H series examples EE EE source code and online manuals for your H Senes PCL OCX gt product D ee wie si HDAS LV Drivers a _ GRRE Manuals ed LV Examples Help The following components are installed DLL Driver examples amp manuals PCL OCX examples amp manuals Please ensure that all Device Drivers and Applications are installed first
30. o 400 C 1 0 C E thermocouple 0 to 1000 C 1 0 C R thermocouple 500 to 1750 C 1 2 C S thermocouple 500 to 1750 C 1 2 C B thermocouple 500 to 1800 C 2 0 C NOTE Due to the location of the CJC sensor the measurement will have a 1 C max difference in channels 36 Copyright 2009 CyberResearch Inc CyberResearch Data Acquisition HUDAS TC A 3 Isolated Digital Input Table A 3 Isolated Digital Input Channels 8 Interrupt Inputs N A Optical Isolation 2500 VDC Opto isolator response 25 us time ESD 2 000 VDC Input Voltage VIH max 30 VDC VIH min 5 VDC VIL max 3 VDC Input Current 10 VDC 2 9 mA typical 12 VDC 3 5 mA typical 24 VDC 7 2 mA typical 30 VDC 9 1 mA typical A 4 Isolated Digital Output Table A 4 Isolated Digital Output Channels 8 Optical Isolation 2500 VDC Opto isolator response time 25us Supply Voltage 5 30 VDC Sink Current 200 mA max ch 1 1A total CyberResearch Inc 25 Business Park Drive Branford CT USA 3 P 203 643 5000 F 203 643 5001 www cyberresearch com HUDAS TC CyberResearch Data Acguisition S A 5 General Table A 5 General 1 0 Connector Type Removable 10 pin screw terminal x 4 Dimensions LxWxH Watchdog timer Power requirements 132 x 80 x 32 mm 5 2 x 3 2 x 1 3 Yes USB
31. put tab to bring it up to front of the screen Select the input range for each channel in the nput range drop down boxes Config ure the sampling rate on the scroll bar Switch the channels by using the up down arrow 20 Copyright 2009 CyberResearch Inc CyberResearch Data Acquisition HUDAS TC A CyberResearch Device Test Analog input Analog output Digital input Digital output Channel No Input range Analog input reading aor uu Ce aw 40576170 16 single ended channels 10 zi BEC Sampling period 1000 ms a D Change device Exit Figure 2 6 Analog Input Tab Device Test Dialog 2 5 2 Testing Analog Output Function Unsupported on this module r Device Test EE Analog input Analog output Digital input Digital output Function not supported Change device Exit Figure 2 7 Analog Output Function Not Supported CyberResearch Inc 21 25 Business Park Drive P 203 643 5000 F 203 643 5001 Branford CT USA www cyberresearch com HUDAS TC CyberResearch Data Acguisition 2 5 3 Testing Digital Input Function Click the Digital Input tab to show the Digital Input test panel as seen below By the color of the LEDs you can easily discern whether the sta tus of each digital input channel is high or low Red lamp High Green lamp Low ER CyberResearch Device Test HUDAS TC BoardID 1 kaja Analog input Analog output Digital input D
32. rch product for use in life support systems medical equipment and or medical devices without the written approval of the President of CyberResearch Inc Life support devices and systems are devices or systems which are intended for surgical implantation into the body or to support or sustain life and whose failure to perform can be reasonably expected to result in injury Other medical equipment includes devices used for monitoring data acquisition modification or notification purposes in relation to life support life sustaining or vital statistic recording CyberResearch products are not designed with the components required are not subject to the testing required and are not submitted to the certification required to ensure a level of reliability appropriate for the treatment and diagnosis of humans CyberResearch Inc iii 25 Business Park Drive P 203 643 5000 F 203 643 5001 Branford CT USA www cyberresearch com HUDAS TC C yberResearch Data Acquisition Revision History Revision Description Date of Issue 1 0 Initial Release April 2007 2 0C Revision July 25 2009 iv Copyright 2009 CyberResearch Inc CyberResearch Data Acquisition HUDAS TC Chapter 1 Introduction 2 My SA 2 AU AAA AAA AA AAA 2 12 ADON aaa a EE AE 3 1 3 Installation Guide ete uscavat st rames 3 Figure 1 1 Installation Flow Chart s w we 4 1 4 Software Overview nn Rene 5 1 4 1 P
33. rivers with your favorite development tools such as Visual C Visual Basic Delphi or C Builder The step by step instructions on how to build your own applica tions using each development tool will be given in the Device Drivers Manual see section 2 21 Moreover a rich set of example source code is also given for your reference 1 5 1 Programming Tools Programmers can develop application programs with the following devel opment tools e Visual C e Visual Basic e Delphi e C Builder For instructions on how to begin programming in each development tool CyberResearch offers a Tutorial Chapter in the Device Drivers Manual for your reference Please refer to the corresponding sections in this chapter on the Device Drivers Manual to begin your programming efforts You can also look at the example source code provided for each programming tool since they can get you very well oriented See section 2 21 for further details 6 Copyright 2009 CyberResearch Inc CyberResearch Data Acquisition HUDAS TC 1 5 2 Programming with Device Drivers Function Library CyberResearch Device Drivers offer a rich function library that can be utilized in various application programs This function library consists of numer ous APIs that support many development tools such as Visual C Visual Basic Delphi and C Builder 1 5 3 Troubleshooting Device Drivers Error Driver functions will return a status code when they are calle
34. rogramming Choices for DA amp C Module 5 1542 Device Drivers aa 5 1 5 Device Driver Programming Roadmap lt v 6 1 5 1 Programming Tools nent en et 6 1 5 2 Programming with Device Drivers Function Library 7 1 5 3 Troubleshooting Device Drivers Error lt lt lt lt 7 Chapter 2 Installation ss000000s0s000000000000ee 10 21 Unpacking Wa kai 10 2 2 Driver Installation wwwmmwemememmnwo 10 Figure 2 1 Automation Software Setup Screen 11 2 21 Programming Examples amp Online Manual Installation 12 2 5 Hardware Installation ses ne anne 14 Figure 2 2 Device Manager Screen vw 15 Figure 2 3 HUDAS TC Device Speed 15 2 4 Device Setup amp Configuration 16 2AT Setting Up the DEVIS de 17 Figure 2 4 Device Manager Dialog Box c 17 2 4 2 Configuring the Device Saisies en AE td 17 Figure 2 5 The Device Setting Dialog Box 18 23 Device Testing SA SPA WA an ra iea 20 2 5 1 Testing Analog Input Function lt w wwwmmowe 20 Figure 2 6 Analog Input Tab Device Test Dialog 20 2 5 2 Testing Analog Output Function lt w ww 21 Figure 2 7 Analog Output Function Not Supported 21 2 5 3 Testing Digital Input Function sens 22 Figure 2 8 Digita
35. sers Manual The HUDAS TC card harbors certain electronic components vulnerable to electrostatic discharge ESD ESD could easily damage the integrated circuits and certain components if preventive measures are not carefully paid attention to Before removing the card from the antistatic plastic bag you should take following precautions to ward off possible ESD damage e Touch the metal part of your computer chassis with your hand to discharge static electricity accumulated on your body Or one can also use a grounding strap e Touch the antistatic bag to a metal part of your computer chassis before opening the bag e Take hold of the card only by the metal bracket when removing it out of the bag After taking out the card first you should e Inspect the card for any possible signs of external damage loose or damaged components etc If the card is visibly damaged please notify our service department immediately Avoid installing a damaged card into your system Also pay extra caution to the following aspects to ensure proper installation e Avoid physical contact with materials that could hold static electricity such as plastic vinyl and Styrofoam e Whenever you handle the card grasp it only by its edges DO NOT TOUCH the exposed metal pins of the connector or the electronic components Note e Keep the antistatic bag for future use You might need the original bag to store the card if you have to remove the card from PC or transport it
36. sted together and shielded with a metal mesh The metal mesh should only be connected to one point at the signal source ground Avoid running the signal cables through any conduit that might have power lines in it CyberResearch Inc 33 25 Business Park Drive P 203 643 5000 F 203 643 5001 Branford CT USA www cyberresearch com 34 HUDAS TC CyberResearch Data Acquisition e If you have to place your signal cable parallel to a power line that has a high voltage or high current running through it try to keep a safe dis tance between them Or place the signal cable in a right angle to the power line to minimize the undesirable effect Copyright 2009 CyberResearch Inc APPENDIX Specifications HUDAS TC CyberResearch Data Acquisition Appendix A Specifications A 1 Analog Input Table A 1 Analog Input Channels 8 differential Input type mV V and mA Input range J K T E R S and B Thermocouple Uni polar 0 15mV 0 50mV 0 100mV 0 500mV 0 1V 0 2 5V O 20mA 4 20mA Sampling rate 10 samples s total Accuracy 0 1 or better voltage and current input Zero drift 0 3 uV C Span drift 25 ppm C CMR 50 60 Hz 92 dB Input impedance 1 8M A 2 Accuracy for Thermocouple Table A 2 Accuracy for Thermocouple Input Range Typical Accuracy Maximum Error J thermocouple 0 to 760 C 1 0 C 1 5 C K thermocouple 0 to 1370 C 1 0 C 1 5 C T thermocouple 100 t
37. you can easily identify the device you are operating CyberResearch Inc 17 25 Business Park Drive P 203 643 5000 F 203 643 5001 Branford CT USA www cyberresearch com HUDAS TC CyberResearch Data Acguisition Restore will reset device configurations to the factory settings Note Please refer to Appendix C for a detailed calibration procedure Device Setting Firmware Version 1 1 4 1 X Identify Board D 0 i 2 Label string 32 characters most 3 l Channel Settings 4 Channel Input Range Value Burn Out Return Value 20m Current Temperature CH3 0 l CH4 0 0 015 l CH5 0 001 CHE CH 5 6 7 8 Figure 2 5 The Device Setting Dialog Box 1 Board ID Set the Board ID for easy identification 2 Locate The on module LED indicator blinks when you continually press Locate button 3 Label string Edit the string label for identification purpose 18 Copyright 2009 CyberResearch Inc C yberResearch Data Acquisition HUDAS TC 4 AI Channel setting Set the thermocouple type analog input range for each AI channel 5 Sample Rate adjustment Drag the slide bar to adjust the sampling rate of your device 6 Restore Restore the AI Calibration setting or the CJC offset setting to default Restore Setting Tif 7 CJC Offset Adjust CJC offset setting CJC Offset Adjustment CIC Offset Adjustment Adjustment TOG tool AAA PR
Download Pdf Manuals