GO2Altitude® HYPOXICATOR (High Altitude Simulator

image

Contents

1. so a f 0 f ij 5 6 L g TIME Total 10 minutes Show This button enables the display of Saturated blood O levels SpO These scroll buttons permit the setting of the baseline level of the percentage of arterial blood oxygen saturation below which level the software will start to alarm the operator 2003 BIOMEDTECH Australia Pty Ltd GO2AIltitude Software Manual 7 Heart Rate and Show Buttons Simply these buttons set the baseline Heart Rate above which the program starts to alarm Station and Mode Selection prape ZTATIONZ ES e The Station and Mode Selection buttons are located A cacra SEDEN in the lower portion of the GO2Altitude Software Ts rE User Screen directly to the left of the Message Display Window The function of these buttons is as follows age a Stations Dependent on the model of hypoxicator used if more than one station is in use this function allows the operator to select which station information is to be displayed Clicking this button to display the details of the station monitored will also result in the illumination of a confirmation on light next to the button concerned m zations _ If no stations are activated the selection buttons are unavailable greyed out When a station is activated and the program of treatment is started its corresponding button becomes active Gaal ncuei seein Mode Selection The New Session butt
2. The user is also able to print store and export to MS Excel all the data contained within this screen From within MS Excel the user may also manipulate the data to display other types of graphs for example Ed Microsoft Excel Booki B File Edit View Insert Format Tools Data Window Help Acrobat T Ea ee ea Session Test 03 Apr 03 12 10 28 pm 2 Person Juliette 02 Concentration 11 B Series E Seres2 O Serless O Serles4 2003 BIOMEDTECH Australia Pty Ltd 16 GO2Altitude Software Manual Course Statistics Within the GO2Altitude History display screen there is also the Course Statistics checkbox Located directly to the right of the Global and Session Statistics buttons the Course Statistics checkbox when selected displays the statistical averages recorded over a range of hypoxic training sessions ee a oe ee L soz Sessions SpO min 87 Average SpO2min 92 Average SpO2 93 MaxHfi 137 Average HR 91 iii D Ai p Sip TIH SH 120114 42 PERSON OLEG mses gekte de rum oun Each Hypoxic training session is displayed in a range scaled according to the number of sessions with the date and time details shown on the lowermost part of the graph and the SpO2 and Heart Rate parameter minimums and maximums displayed in the uppermost portion of the same window Again data may be exported to another program for table and or graphical manipulation 2003 BIOMEDTECH Australia Pty L
3. follows Help Calls the GO2Altitude Hypoxicator online help manual Measurements Calls into action the precise point measurement lines used to display detailed data at a given section of the displayed graph By positioning the cursor at the point required and clicking the left mouse button a line of measurement will be inserted and the data for that point displayed 2003 BIOMEDTECH Australia Pty Ltd GO2Altitude Software Manual 13 i N Fi l 4 As f a E h a d a E af hal 2 10 26 AM Fide 11 spO2mi we So a 7 a j E inn i EE an r E E E i 4 OA heal ys wa E L i a 5 PERSON JULIETTE TOH 315 TR 0 These precise point measurements are particularly useful in displaying the heart rate or an exact percentage of SpO at any given time Each measurement line is movable across the range 50 28 and multiple measurement lines may be inserted move The Move buttons control the incremental E 5 r3 movement of the measurement lines Clicking the rg Paley wan Fp button denoting a left or right direction will move j f the line in that direction Dragging with the mouse will also effect this pT The Time Interval buttons alter the time increment shown on a f amp E 3 the Graphical Display Window Each interval can be changed to i a preset selection of 10 30 or 60 minutes Data Manipulation and Export Directly to the right and on the same level of the Message Di
4. station and is a realtime textual representation of the information shown in the Graphical Display Window The data exhibited includes the Station Number being used represented as a number with a hash on the left of the display and as a list number on the right side of the window The SpO is shown as a percentage and the heart rate is given in Beats Per Minute BPM The information is displayed in a larger form to the left of the window to allow for reading from a distance for example when the user is seated some distance from the computer 2003 BIOMEDTECH Australia Pty Ltd GO2AIltitude Software Manual Time Interval and Message Size Buttons pm DISPLAY 0 miin 30 min BO mMin Al activated le u i 2 STATION PERSON SpO Baseline Levels SHOW FOE L The Time interval and Message Size buttons are located on the lower right portion of the GO2Altitude Software Session screen previously described The Display button simply enables the viewing of the larger message on the left hand portion of the Message Display Window previously described see Message Display Window The inbuilt green light glows when the button is The Time Interval buttons alter the time increment shown on the Graphical Display Window Each interval can be changed to a preset selection of 10 30 or 60 minutes as shown in the following section from the Graphical Display Window Time increments T
5. BIOMED I ECH Biomedical Research and Development GO2Altitude HYPOXICATOR High Altitude Simulator PC SOFTWARE MANUAL 2003 BIOMEDTECH Australia Pty Ltd GO2AIltitude Software Manual 1 TABLE OF CONTENTS THE GO2 ALTITUDE SOFTWARE SESSION SCREEN cccccssecccessccceescceeeseceeeeceeeeeecees 2 THE GO2 ALTITUDE SOFTWARE HISTORY SCREEN sssssssssssesesssresssrerercreserreserreserreseee 3 REAL TIME SCREEN FUNCTIONS seesseesseessecssecssecssesssesssesseesssosseesseesseosseosoe 3 REAL TIME SCREEN FUNCTIONS sseesseesseesssossocssesssecssesssesssesssesseesseosseosseosoe 4 OVERVIEW oorr T a dae eiesunenaatomaveeaas 4 The Graphical Display WiInNdOW sppcerseeninidetas een a ea GadtobaNiesdaas ob eadetabeas 4 PON CRON CONTROLS ean A N N T ENE 4 CoO DUO S aE E E AE E ease icir sae 4 Message Diplay WINGOW desiree nane E E E E E AEE 5 Time Interval and Message Size Buttons oonnnneeeenssnnnnnesseeensssseeressssseressssseresssses 6 SPO Baseline Levels ds cassts utes cule lchsctekde toasty ENAERE A E OEE 6 Heart Rale and SNOW DUTIONS aiig a E 7 Saton and Mode Select oN nrin nia ere O a EN T a A N eceust 7 HYPOXIC STren a a E cadens diane ehes 8 MESSA PCS DUS DUG VCO EErEE TEE reed 9 HISTORY SCREEN FUNC TIONS sssiscsscicesescasscicsusscoschsseiieccascepestssssieiwsseagenescedincss 10 COMER EW isc slevadeicic srotie osiadisaattarat aren dara oda ee 10 L adn o SCS S81 OW COAG e E ound ects atone eG 10 The Gr
6. Window will display certain parameters SpO gt scale Overall Session s statistics Sessione 3 SpOenines Average SoOeminebs Average SoO2e95 Max HRe S Average Hieo2 TW Heart rate scale Average SpOz achieved Minimum SpOs f J 4 1 l Maximum Heart rate 00 f i i A a a0 P z 3 Average Heart rate m T T z g TO 3 15 TR O0 PERSON JULIETTE User selected Time to Time to Descend Recovery 2003 BIOMEDTECH Australia Pty Ltd GO2AIltitude Software Manual 15 Control Buttons The functions allocated in Global Statistics mode are fundamentally the same as those available in the Session Statistics mode see Control Buttons in the section Session Statistics for the correct use of these buttons with the exception of an additional checkbox The full STAT or Full Statistics button is used to display all recorded sessions as a function of saturated blood oxygen levels and heart rate linearly Epo Sessonse SpOemines Average SpOemine 92 Average 5pO0ee99 PlaxHRel3 Average H 100 aa Se kur ie Ey Sir LASS AAT ee HF ah PERSON OLEG kar 24 Apr 03 12 00 09 AM Fi02 115 4 Apr 03 12 06 08 AM AOZ 11 24 apr 09 12 06 18 AM FI0Z 115 Ea i al i Li at ith m T o raj qi ak L N rn TF Pa 2 ApreO3 12 02 46 AM Fi0 11 24 Apr 03 12 04 55 AM FrO2 11 Che d h ba a8 a 2 i g 5 i
7. aphical Display Window Session Statistics cccccccccccceesseeesesceceeeeseaeeeess 12 FUNCTION CONTROLS asrni salnniovatannsseaevenczatsunscceudvendisaausyianadieadedtassatseedpansiencueoren 12 CONG OPTIONS ac sete Saas eet area T anemia O E catered 12 Data M nipulation and EXPO acted dosecpatccssansabantnebees aed dene ECA EAT 13 The Graphical Display Window Global Statistics ccccccccccccessseeeeeececeeeeeaseeees 14 CONTROL BUTTONS aA AA A 15 Cone TaS N O Sraa A A 16 OPERATION OF THE GO2ALTITUDE SOFTWARE sccssccssccscsees 17 PRELIMINARIES marena a a a A a 17 IRCCOTOIN GO SES O as e a A O NS IS ORIN DBPLAY OPITTONS aorin 19 GLOSSAR Vairinen E T eso ase eee 20 2003 BIOMEDTECH Australia Pty Ltd 2 GO2Altitude Software Manual Program Overview GO2Altitude software consists of two separate modules a real time Graphical User Interface GUI used to monitor hypoxic training sessions and another GUI specifically designed to view manipulate access and store data from a history of hypoxic training sessions Each module is selected from a specific icon located on the computer desktop during installation of the software Each of these systems will be explained in turn The user may also select from two distinctive skins for their GO2ALTITUDE display when the program is started For the sake of clarity this manual will use the CRT skin see the Skin Display Options section for furthe
8. d and is measured as Tr or Time to Recovery and is shown with the Td measurement in the display window as illustrated Once the Hypoxic Test Hypoxic Test Result Xi has been conducted a H c testi lea dialog box will be YPOXIC test for oleg displayed showing both Td 15s the Td and Tr results as Tr 36s Shown at left From here the user may elect Print Send by E mail Save File to save print or email the information 2003 BIOMEDTECH Australia Pty Ltd 10 GO2AIltitude Software Manual History Screen Functions Overview To access the History screen the operator selects the GO2Altitude History icon from their PC desktop as shown at left 60 Altitude History Loading session data Once the GO2Altitude History icon has been selected a dialog will display as follows Choose skin EJ For new users click on the OK button only Preview WOE sessions Ok Cancel Interface skin CRT Panel For previous users click on the Import V 2 sessions button to load saved session data from previous versions of the software This will then display a dialog in which the operator may browse for suitable files Import Go Altitude version Z sessions data Once the appropriate files have been selected click on the Import button to load them to the GO2Altitude History screen Enter directory with version 2 data files c Program Files G02 Altitude Bro
9. gher then baseline Take the mask OFF until HA decreases below the baseline Take note of the message displayed and comply with the warning s The user must take the mask off and take 2 to 3 regular breathes in and out 2003 BIOMEDTECH Australia Pty Ltd GO2Altitude Software Manual 19 8 To manipulate the graph see the relevant sections elsewhere in this manual NOTE Operation of the GO2AItitude system may be found in much greater detail in the full Operations Manual accompanying the GO2Altitude Hypoxicator equipment Skin Display Options The GO2Altitude Software System comes with two separate display options to suit individual user s tastes Each of these options functions in exactly the same way in all respects excepting that the display itself has different styles of buttons display and location of functions dhe deh ae a w a a re a q a Hei ar BUR Ti F int Spr MR HR SYEPM 4 Heena SOOO LE lt 7 Standard CRT Display Screen A GO Altitude Hypoxicator Optional Blue Display Screen 2003 BIOMEDTECH Australia Pty Ltd 20 GO2AIltitude Software Manual The user is able to select the required skin from the drop down option box displayed at the start of every session Glossary Pulse Oximeter Pulse oximetry is a simple non invasive method of monitoring the percentage of haemoglobin Hb in the blood that is saturated with oxygen The pulse oximeter ge
10. ining regime The information displayed may be stored on the host computer be printed as required or manipulated in a variety of other ways including export to a spreadsheet program such as MS Excel or to a database such as MS Access as a delimited text file Each of the functional areas shown will be discussed in turn in the following sections of this manual 2 HISTORY GO2Alitude Hypoxicator pp Lo ae Session FC Seita 2 Se PP Fee LO Severe CL PA Fee LS HF w i g MAY AN Si cad an ETA K F W i n 4 gi r Y bt vA VATA SW PERSON EART LAST SESS Statistics mode buttons Graph control buttons and Help User and session Data manipulation selection and export 2003 BIOMEDTECH Australia Pty Ltd Graphic display window Time intervals 4 GO2AIltitude Software Manual Real time Screen Functions Overview The GO2Altitude Software User Screen is accessed from its specific 4 K icon on the computer desktop Gozaltitude To more clearly describe the screen functions the main screen will be explained in two sections corresponding to the titles shown in the graphic GO2Altitude Software User Screen The first section describes the Graphical Display Window whilst the second section describes the Function Controls and the smaller Message Display screen The Graphical Display Window Heart rate SpO gt level scale Hy
11. n 2 MAS MJA Foe A BD I E A AAA o 10 f 430 i ff _ a a _ we eT Le me PERSON JULIETTE Heart Rate scale Precise point measurement ki i tiahia i q TO 3 15 TR O oe Person in test history Time to Time to Descend Recovery 2003 BIOMEDTECH Australia Pty Ltd 12 GO2AIltitude Software Manual The Graphical Display Window Session Statistics To more clearly describe the screen functions the main screen will be explained in two sections corresponding to the titles shown in the graphic GO2Altitude Software History Screen The first section describes the Graphical Display Window whilst the second section describes the Function Controls and the smaller Message Display screen The GO2ZALTITUDE History Software Graphical Display Window consists of several distinct functions There are two displays from which to choose the Session Statistics function and the Global Statistics function each of which is selected from the button found in the centre of the display directly below the Graphical Display Window These buttons toggle between the two functions and the display and controls change accordingly The first of etnias these the Session Statistics mode is as follows Function Controls Control Buttons The Control Buttons are located on the lower left section of the GOZALTITUDE History software screen The function of each of these buttons is as
12. n to this test is a gradual decline in SpOQ how much oxygen the blood carries The time taken to reach the baseline level set is known as the time to descend or Td Once the baseline level has been reached the software prompts to remove the mask Upon removing the mask the person under test will once again be breathing ambient air and their SpO level should start to return to a level of 95 or more The time taken to return to this normal level of SpO is known as the Time to recover or 66 r Based upon the results observed an IHT practitioner can determine an individual s sensitivity to hypoxic breathing general level of fitness and in athletes and mountaineers the level and effects of training SpO2 The percentage level of haemoglobin saturated with oxygen in the user s system This is an indication of the level of oxygen being carried by the bloodstream in a given Hypoxic training session Td Time to Descend The time period taken for the user s SpO gt levels decrease from their normal values of around 95 to 100 at sea level below the pre set value normally set at 85 Tr Time to recovery The time period elapsed from the point where the user reverts to breathing ambient air until their SpO gt levels rise to 95 or more 2003 BIOMEDTECH Australia Pty Ltd
13. nerally consists of a probe attached to the patient s finger or ear lobe that is linked to a computerised unit The unit displays the percentage of Hb saturated with oxygen together with an audible signal for each pulse beat a calculated heart rate and in some models a graphical display of the blood flow past the probe Audible alarms that may be programmed by the user can also be provided A pulse oximeter detects hypoxia before the patient becomes clinically cyanosed A pulse oximeter works by generating a source of light at two wavelengths 650nm and 805nm This light is partly absorbed by haemoglobin by amounts that differ depending on oxygen saturation levels By calculating the absorption at the two wavelengths the processor can compute the proportion of haemoglobin oxygenated Hypoxicator A device designed to provide the user with reduced oxygen hypoxic air for breathing Hypoxic test The hypoxic test is used to assess a person s individual response to Kitude Hypoxicator oe Take the mask OFF na Hypoxic Hypoxia That is their response to breathing air with a reduced Oz content During this test the person under test is first required to breath hypoxic air of a known composition recommended to be 11 through a mask whilst their individual physiological parameters heart rate and SpOs specifically are monitored The 2003 BIOMEDTECH Australia Pty Ltd GO2AIltitude Software Manual 21 normal reactio
14. on simply m m allows the operator to initiate a new session and select a station if applicable The Stop and Stop All buttons put a halt to any current session or sessions respectively The user must select the New Session button to reinitiate a session The Hypo Test button is used to start the special mode Hypoxic Test 2003 BIOMEDTECH Australia Pty Ltd 8 GO2AIltitude Software Manual Hypoxic Test In order to determine a user s respiratory condition and to determine the base level reference of their fitness health level a hypoxic test is recommended The information is collected over a maximum period of ten minutes where the Pulse Oximeter finger clip on sensor is used to measure heart rate and SpO levels and the results are displayed graphically using the GO2Altitude software This is performed in real time with a one second sampling frequency SpO gt 2 scale SpO base level set Heart rate base level set 110 E a fx J dla Heart rate scale i40 m Ja 130 120 i 10 7 100 eee ee ee erro a a a me Ri Haars eae Foon aia TR AAN a m n o j al Al EAAS EEA EITRI KERAS ESAERA A VEEE ria bien UA EEIN OUEST MiP ANAA KAA SENTAN AA ISPALA EN DeLee EAS Wes R Cree ynesh bal i i 4 i 1 5 q j 2 UR if STATION 1 PEFSON OLEG Station in use Person being tested Elapsed time The Hypoxic Test helps indicate an individual s reaction to low oxygen respi
15. poxic air versus ambient air intake _ STATION 1 PERSON OLEG TIME 0 00 32 Station Current user Elapsed monitored session time As illustrated the Graphical Display Window shows the real time data of the Selected Station see Stations in the section Function Controls in a comparative graphical form As such this window shows the variance in Heart Rate and Arterial Oxygen Saturation SpO2 over a given period of time Function Controls Control Buttons The Control Buttons are located on the lower left section of the GO2Altitude Hypoxicator software screen The function of each of these buttons 1s as follows 2003 BIOMEDTECH Australia Pty Ltd GO2AIltitude Software Manual 5 Help Calls the GO2AItitude Hypoxicator online help manual Alarm Enables the warning buzzer to indicate that oxygenation levels are too low The inbuilt green light glows when the button is activated The Reset button clears resets the software and clears the screen to allow taking of new measurements Messages Selecting this button enables messages in the Message Display window Message Display Window Located to the right below the Control Buttons is the Message Display Window SpO2 SET HYPORIA 1 Hypoxia 5p02 98 H R 87 SPOR S8 Not active H R BT EPM SpO2 4 Not active Heart rate Station s activity Heart rate The Message Display Window shows the information obtained from a selected
16. r information The GO2Altitude Software Session Screen GO2Altitude software is specifically designed to complement the GO2Altitude range of hypoxicator systems Utilising the GO2Altitude integral Pulse Oximeter see Pulse Oximeter in Glossary at the end of this manual physiological information such as heart rate and arterial oxygen saturation is monitored recorded and displayed on a standard Windows based computer during intermittent hypoxic training sessions This information is then used to assist in determining the current state of an individual s fitness their reaction to hypoxic stimulation and the degree to which their body has responded to the treatment The information received by the GO2Altitude software is displayed on a multtfunction screen that plots the various input parameters heartbeat O2 saturation against specified time intervals a GO2Altitude Hypoxicator gt The Graphical Display Window I E STATION PERSON Time intervals and message size Control buttons Show arterial O2 saturation baseline Heart rate Station and mode Message display selection 2003 BIOMEDTECH Australia Pty Ltd GO2Altitude Software Manual The GO2Altitude Software History Screen In addition to the Software Session Screen the GO2Altitude Software System also allows the user to access and compare stored data from a history of hypoxic sessions to assist in the analysis of their tra
17. ration By default or by connection the oxygen saturation base line is set automatically to 85 for all people Please refer to the main Hypoxicator User Manual for further information The results of this test are also displayed textually in the Message Display window simultaneously 1 Rest Sp02 97 H R 77 Combined results SP POE 317 5 Not ative H R TIEPM amp 4 Not active Station activity Heart rate 2003 BIOMEDTECH Australia Pty Ltd GO2Altitude Software Manual 9 Messages Displayed The Hypoxic Test screen continuously plots a graph of SpO and Heart Rate on the screen at one second intervals as the hypoxic test is being conducted HA b 6 a 8 eB 1 3 STATION 1 PEFSON LARA neo TIME 0 02 08 One result of this test is known as the Time to Descend or Td 4 G This figure is displayed constantly in the lower right hand portion of Tos TI the Hypoxic Test display window as shown and actively refers to the time taken for the user s SpO level falls below 85 NOTE As a rule of thumb the length of the Td parameter reflects the level of general respiratory and aerobic fitness of an individual Generally the longer the Td the higher the fitness level of the person under test Once the Td has been reached the user is advised by the software to remove the mask and revert to breathing ambient air From here the recovery test is started when an SpO level of 95 is reache
18. splay boxes are the Function Buttons Clean up Data The Clean up Data checkbox smooths the graphical data displayed by averaging the measurements to remove the strictly linear appearance Print Graph The Print Graph button outputs the graphical display directly to a printer connected to the computer G Export 2 2a The Export to Excel button allows the user to transfer the history results directly into the spreadsheet program MS Excel as a delimited text file This results in the user being able to further manipulate store and display the collected history data 2003 BIOMEDTECH Australia Pty Ltd 14 GO2AIltitude Software Manual The information shown in Excel may be then transformed Ed Microsoft Excel Booki B File Edit view Insert Format Tools Data window Help Acrob B21 Lil OEE e o A Session Test 03 Apr 03 12 10 28 pm graphical display Person Juliette methods available O Concentration 11 including graphs wil and pie column and line charts Time sec SpO HR 0 97 57 The Graphical Display Window Global Statistics The inverse toggle to the Session Statistics mode is the Global Statistics mode This mode displays a summary of all sessions undertaken Selecting this mode changes the Graphical Display Window contents as well as the function and selection buttons relevant to use in this mode STATISTICS Independent of the session s selected the Graphical Display
19. td GO2Altitude Software Manual 1 Operation of the GO2Altitude Software Preliminaries After the installation of the software to the computer and the supplied serial cable is connected to both the GO2AIltitude Hypoxicator machine and the computer itself the software is ready to use The COM port through which the Hypoxicator and the user s computer communicate is set at default to COM port 1 The user is prompted to change this should that particular port be in use for other equipment by opening the Communications menu and selecting a different port from the available drop down list Connect device E4 From here you ue Select device communication COM port com 1 also select the skin for the display see the section Skin Display Interface skin CRT Panel Options for more l information Operation progress Number of stations your hypoxicator supports o Operation status You may also import sessions from previous versions of the software for use by the GO2Altitude History a display see the History Screen UMDU Wek Sete Cancel Functions section for more information Ensure Hypoxicator is switched ON and that cable is connected Then select OK button i L a sports 2 persons From the same window the operator may also elect the model of the Hypoxicator used whether it is a l 2 or 4 person system 2003 BIOMEDTECH Aus
20. tralia Pty Ltd 18 GO2AIltitude Software Manual Recording a Session To record a session the following sequence should be followed 1 Turn on the GO2Altitude Hypoxicator and start the desired Training Program see the full Operational Manual for further information 2 Ensure that the Pulse Oximeter is securely clipped to the user s finger 3 Set the same O gt concentration in the software as that on the GO2Altitude Hypoxicator 4 Choose a user from the Select SAEsuUSDNe User drop down box or Are you sure that you want to delete person oleg add a new user by clicking on the Add User OK Cancel button NOTE To remove a user from the same list select the user and click Remove 5 Information should now begin to appear in both the Graphical Display Window and the smaller Message Display Window 6 The information in the Graphical Display Window will now steadily resolve into a graph at a rate determined by the incremental resolution applied to the screen The line at the lowermost part of this window will display whether the user should be breathing hypoxic air with mask in red or ambient air without the mask in green 7 If the value of the user s arterial oxygen saturation level falls below the selected baseline or 1f the heart rate rises above the baseline an alarm will sound and a warning display will be issued For example j m Tin FIN WARNING STATION 1 Heart Rate is hi
21. wse Operation progress Press Import button to start When complete a message window will display confirming the number of files imported Files may now be accessed directly from within the GO2Altitude History display from selected training sessions 2003 BIOMEDTECH Australia Pty Ltd GO2Altitude Software Manual 11 User and Session Selection To access an individual session or sessions the operator now chooses from a group of drop down boxes Directly below the Measurement Control buttons is a series of drop down boxes that contain information pertinent to the data being displayed on the Graphical Display Window USER NAME Juliette zeen name The first of these windows displays the User selected to display their hypoxic test history Only those users whose data is stored may be accessed Each session is stored separately and may be accessed from this drop down list Select session The Test Session containing the date time and standard oxygen concentration level are selected here TEST sessions U3 4or 03 2 10 26 4M FOZ 11 As illustrated this Window shows the collected history data of the Selected session in a comparative graphical form As such this window shows the variance in Heart Rate and SpOz levels over a given period of time during a selected session Saturated O gt scale Test session details tins se5m0n 3 S 0S Aprsis 2 10 25 AP piim 16 Sp mi

Download Pdf Manuals

image

Related Search

Related Contents

Toshiba X205 Personal Computer User Manual  Poulan P3500 User's Manual  SBS 1.5m USB 2.0 A M/F  Hilfe - Sony Europe  Philips SWV2202W User's Manual  Citizen San Remo Eco-Drive AT0002  Clicar aqui para abrir o ficheiro - Service Citroen  SounderSuite - SBP Software User Manual  ficha comercial  『グリップステーS』の取扱説明書がダウンロードできます。  