1. injury or problems with the product Q Do not attempt to repair disassemble or modify the product yourself gt Do not use any fuse such as copper steel wire etc other than the standard fuse gt Failure to do so may result in electric shock fire problems with the product or injury If any foreign substance such as water has entered the product cut the power by unplugging the power plug and turning the circuit breaker off and then contact your nearest service center gt Failure to do so may result in electric shock or fire FOR OPERATION AN CAUTION Q When an error message is displayed or abnormal operation occurs stop operation of the product immediately gt When abnormal operation occurs turn the product off disconnect it s power supply and contact a service center If the product is used continuously electric shock fire and product malfunction may occur S Do not stand on top of the product nor place objects such as laundry lighted candles lighted cigarettes dishes chemicals metal objects etc on the product gt Failure to comply may result in electric shock fire product malfunction or injury Do not operate the product with wet hands gt This may result in electric shock Do not spray volatile material such as insecticide onto the surface of the product gt As well as being harmful to humans it may also result in electric shock fire or problems with the product Do not press the pro
2. plug into the wall socket in the right direction so that the cord runs towards the floor gt Ifyou plug the power plug into the socket in the opposite direction the electric wires within the cable may be damaged and this may result in electric shock or fire When the product or power plug or power cord is damaged contact your nearest service center OQ Plug the power plug into the wall socket firmly Do not use a damaged power plug damaged power cord or loose wall socket gt This may result in electric shock or fire Do not pull or excessively bend the power cord Do not twist or tie the power cord Do not hook the power cord over a metal object place a heavy object on the power cord insert the power cord between objects or push the power cord into the space behind the product gt This may result in electric shock or fire Do not pull the power cord when unplugging the power plug gt Unplug the power plug by holding the plug gt Failure to do so may result in electric shock or fire FOR POWER SUPPLY AN CAUTION When not using the air conditioner for a long period of time or during a thunder lightning storm cut the power at the circuit breaker gt Failure to do so may result in electric shock or fire HSITDN4 FOR OPERATION AX WARNING If the product is flooded please contact your nearest service center If the product generates a strange noise a burning smell or smoke unplug the power plug immediat
3. product specification may be changed without notice in advance for improvement of product quality gt Ifinstallation is performed with agencies not certified by Samsung Electronics Co Ltd free service will not be available gt Use rated cables for electric work and the additional work such as extension of electric wire or installation of auxiliary power switch will be charged to a customer Product dimension 161mm Contra amp Monitoring TS CE 15 60 04 000 01600 _IB_EN_03944A 1 indd 15 2013 05 28 9 03121 60 04 000 01600 16 61 _03944 1 1000 16 2013 05 28 9 03121
4. will work Sun Mon Tue Wed Schedule Thu Fri Sat Set operation of an indoor unit that will be controlled by schedule Set control time Set On Off Event Set desired temp Select operation mode Select ERV mode Select use of remote controller Modifying a schedule Press the schedule you want to modify to move to the modification screen on the Schedule screen However you cannot modify the schedule that is in operation and can only check the content Deleting a schedule 1 Select the schedule you want to delete 2 Press the Delete button However you cannot delete the shedule in operation Operating stopping a schedule Buttons Description Remarks gt Operation status il Stop status Press the buttons to operate or stop the schedule E X S 2t Ml O1 SOL Touch controller _IB_EN_03944A 1 indd 8 2013 05 28 9 03 20 Setting an excluded day Press the Excluded day button on the schedule screen 1 Adding an excluded day 1 Select the day you want to set as an excluded day on the left calendar 2 Press the m button Description HSITDN4 Selected day Added day Move monthly Move yearly Sunday Select or exclude all Sundays in the current calendar Saturday Select or exclude all Saturdays in the current calendar 2 Deleting an excluded day 1 Select the excluded day you want to delete 2 Press the am button 3 Saving a
5. CAUTION Moving a zone You can move a selected device to another zone Moving a page You can move a selected device to another page You can make a group for the selected devices so that a user can view them as one group When Grouping the devices become a group the last selected device will be the main device and be displayed on the screen Individualizing You can individualize the devices that have become a group Changing a device name Save the zone that a user has edited and the formation of devices A user can change the order of devices with drag amp drop within a page You can change the name of a device When there is more than 1 zone the zone list will be displayed with control amp monitoring When there is one nore zone zone list will not be displayed with control amp monitoring 8 Trouble history gt You can view the history of the errors with a device 9 DI pattern gt You can define rules that operate according to the DI signal Pattern Description of control 1 There is no function When DI 1 ON signal is input emergency stop status will occur It will stop all indoor units and order the indoor units not to be controlled by a remote controller In the emergency stop status you cannot use the user control command In addition the schedule control will not work When the contact control signal is changed to OFF the control command can work normally DI 2 will not b
6. Touch centralized controller MCM A300N 100 Recycled Paper imagine the possibilities Thank you for purchasing this Samsung product K EN DB68 03944A 1 en E X S St Ml 01 D1 SOL Touch controller _IB_EN_03944A 1 indd 17 2013 05 28 9 03121 Safety precautions This content is written to protect a user s safety and to prevent property damage Please read this manual thoroughly and use the product correctly A WARNING Hazards or unsafe practices that may result in severe personal injury or death A CAUTION Hazards or unsafe practices that may result in minor personal injury or property damage Q Must follow directions S Do NOT attempt Make sure the machine is grounded to prevent electric shock Unplug the power plug from the wall socket Q Do NOT disassemble FOR INSTALLATION A WARNING 00 Plug the power cord into a wall socket with the power specifications of the product or higher and use the socket for this product only In addition do not use an extension cord gt Sharing a wall socket with other products using a power strip or extending the power cord may result in electric shock or fire gt Do not use an electric transformer It may result in electric shock or fire gt Ifthe voltage frequency rated current condition is different it may cause fire Never install the outdoor unit in a location such as on a high external wall where it could fall gt Ifthe outdoor unit fal
7. duct with a sharp object gt Failure to comply may result in electric shock or part damage FOR CLEANING AX WARNING S Do not clean the product by spraying water directly onto it Do not use benzene thinner alcohol or acetone to clean the product gt This may result in discoloration deformation damage electric shock or fire Ej X S 2t Ml O1 SOL Touch controller _IB_EN_03944A 1 indd 4 2013 05 28 2S 9 03 19 Name of each part Front view 3X PM 05 45 SAMSUNG Touch Centralized Controller Ver 1 0 0 HSITDN4 Control amp lt h I tt Monitoring Schedule Settings SAMSUNG LCD ON OFF button O Turn the screen of LCD on or off Indoor unit operation lamp Blue Display whether an indoor unit is turned on or off Error lamp Red Display an error with an indoor unit If the color of the LED is red an error has occurred with a device that the Touch Centralized Controller controls Nore Ifthe color ofthe LED is blue a device that the Touch Centralized Controller controls is turned on Side view SD card slot Use the slot when you back up data to SD card or update S W E X S 2t Ml O1D SOL Touch controller _IB_EN_03944A 1 indd 5 2013 05 28 2S 9 03 19 Name of each part Rear view DI 1 DI 2 DO RS 485 communication terminal RS 485 communication terminal Use it to connect the 485 communication terminal of an indoor unit or outdoor unit Digital output te
8. e all user information of a Touch Centralized Controller to a SD card and restore the information from this data gt For the data restoration you need user authentication When using the function of the data backup or data restoration you need to insert the SD card to the Touch CAUTION Centralized Controller 3 Device settings gt You can allow the control of a On Off controller with a remote controller from Touch Centralized Controller and can change the communication address of the Touch Centralized Controller 4 System Initialization gt You can delete all user information of Touch Centralized Controller To use this function you need user authentication Device Information 1 Version information The version information of the Touch Centralized Controller is displayed 2 For the information of open source refer to Setting Device Information 13 E1 x1 S St Ml O1I1 SOL Touch controller _IB_EN_03944A 1 indd 13 2013 05 28 9 03 21 Trouble shooting Before reporting on the product malfunction please check the table below Problem Check Solution Screen of LCD does not show anything Is power supplied correctly After checking the power supply connection plug in the product again Is the product in screen protection mode When there is no input by a user for a certain time the LCD will be turned off automatically Turn the LCD screen on with LCD ON OFF button Indoor un
9. e used with the pattern 2 N e When DI 1 ON signal is input it will stop all indoor units When OFF signal is input all indoor units are ON When DI 2 ON signal is input the remote control status of all the indoor units will be enabled and when the OFF signal is input the remote control status will be disabled w It will operate when pulse signal is input to DI 1 2 as contact input When the pulse contact signal is input to DI 1 ON command will be sent to all indoor units When the pulse contact signal is input to DI 2 OFF command will be sent to all indoor units A 12 E S 2 Ml O1D1 SOL Touch controller _IB_EN_03944A 1 indd 12 2013 05 28 9 03 20 Settings on installation A The menu of settings on installation is only for a certified installer CAUTION 1 Network amp Tracking gt Touch Centralized Controller explores installation information and status information of the devices which form the system for 10 minutes To use this function you need user authentication gt In addition you can select Show Hide _ for the device that has completed the tracking You can also hide the device which is found during the tracking with the Hide function When performing the tracking for the first time all devices will be included in one zone CAUTION The zone information edited by a user will be maintained even if you perform the tracking 2 Data backup amp restoration gt Sav
10. ection of SPi ERV Ventilator DHW Control for hot water supply You can select and control one or multiple indoor units When choosing an indoor unit and selecting the on off you can turn on off the device After choosing an indoor unit and selecting control you can control many control items such as desired temp mode etc The control panel displays the status of the last selected device The special functions such as operation mode limit cool lower limit or heat upper limit can be controlled by selecting the advanced operation vvv v v x When there is only one zone it will not be displayed but the devices within the zone will be displayed caution For detailed information on icons refer to the legend Ej X S 2t Ml O1 SOL Touch controller _IB_EN_03944A 1 indd 7 2013 05 28 2S 9 03 19 Functions of Touch Centralized Controller Schedule Touch Centralized controller can control the operation information of an indoor unit with a schedule gt You can set a maximum of 10 schedules for a week gt One schedule can set a maximum of 10 events gt When setting an excluded day all the set schedules will not work on the corresponding day Create a schedule 1 Select the New button 2 Items for creating a schedule Items Description Remarks Name Enter the name of the schedule Indoor unit Select the indoor unit that will be added to schedule control list Select the day that the set schedule
11. ely and contact your nearest service center gt Failure to do so may result in electric shock or fire In the event of a gas leak such as propane gas LP gas etc ventilate immediately without touching the power cord Do not touch the product or power cord gt Donotusea ventilating fan gt Aspark may result in an explosion or fire To reinstall the air conditioner please contact your nearest service center gt Failure to do so may result in problems with the product water leakage electric shock or fire gt A delivery service for the product is not provided If you reinstall the product in another location additional construction expenses and an installation fee will be charged gt Especially when you wish to install the product in an unusual location such as in an industrial area or near the seaside where it is exposed to the salt in the air please contact your nearest service center E X S 2t Ml O1 SOL Touch controller _IB_EN_03944A 1 indd 3 2013 05 28 2S 9 03 18 Safety precautions FOR OPERATION AX WARNING OQ Do not touch the power plug with wet hands gt This may result in electric shock After unpacking the product keep all packaging materials well out of the reach of children as packaging materials can be dangerous to children gt Ifa child places a bag over its head it may result in suffocation app Do not strike or pull the air conditioner with excessive force gt This may result in fire
12. erature display unit You can set the temperature unit as Celsius or Fahrenheit 4 Language gt Touch Centralized Controller supports Dutch English French German Greek Turkish Italian Korean Polish Portuguese Slovak Spanish and Chinese 5 Time amp Date Settings gt Date Time You can set the date and time of the Touch Centralized Controller You can also set the time as 24 hours display N w e Ifyou enter the date and time incorrectly the schedule will not work as you want CAUTION gt Select a time zone You can set the time zone of the selected country The summer time of the selected country will be automatically applied When the summer time is applied the icon on the upper screen will be changed from 22 to 10 E1 xl S St Ml 01 I1 SOL Touch controller _IB_EN_03944A 1 indd 10 2013 05 28 9 03 20 Screen settings Brightness You can adjust the brightness of LCD screen of Touch Centralized Controller Backlight timeout You can adjust the time for turning the backlight off Setting amp Editing Zone Touch centralized controller can conveniently control the installed indoor units by setting a zone or modifying the name of zone and indoor unit gt All the devices in the Touch centralized controller are included in a group called zone and it is shown by page unit The page unit is displayed as number such as 1 2 and 3 Each page has a device Zone Page Device gt The zone can be cus
13. it control does not work Desired temperature does not increase or decrease Remote controller does not work Is the communication cable unplugged Has Heat upper limit or Cool lower limit been set Is the use of the remote controller restricted Check the connection status of Communication cable between an indoor unit and outdoor unit When the temperature limit is set a user can adjust the desired temperature within the range of the temperature limit If the Remote control level is set as Disable RC you cannot control the indoor unit with wireless or wired remote controller Schedule control does not work with the set time Is the set time of product different from current time Set the current time again at the menu of Setting System Settings Time amp Date Settings Modifying a schedule is not available 14 Is the schedule in operation E amp S St Ml O1 SOL Touch controller _IB_EN_038944A 1 indd 14 Modification of a schedule is available only in stop status 2013 05 28 9 03 21 Product specifications Model MCM A300N Display 7 inch capacitive touch 800 480 Operating system Linux 2 6 35 3 CPU IMx53 5 Memory RAM 512MB ROM 1024MB T Expansion slot SD Card Interface Reset button Touch button Communication terminal RS485 Digital Input Digital output Using type Wall mounted type Power supply 100 240 V 50 60 Hz gt Design and
14. ls it may result in injury death or property damage OQ Do not install this product near a heater inflammable material Do not install this product in a humid oily or dusty location in a location exposed to direct sunlight and water rain drops Do not install this product in a location where gas may leak gt This may result in electric shock or fire Do not connect the power cable to control terminal gt Failure to comply may result in electric shock or fire a This product must be properly grounded Do not ground the product to a gas pipe plastic water pipe or telephone line gt Failure to do so may result in electric shock fire an explosion or other problems with the product FOR INSTALLATION A CAUTION T This product should be positioned in such a way that it is accessible to the power plug gt Failure to do so may result in electric shock or fire due to electric leakage Install the product on a hard and even place that can support its weight gt Ifthe place cannot support its weight the product may fall down and get damaged Ej X 3 2t Ml Ol D SOL Touch controller _IB_EN_03944A 1 indd 2 2013 05 28 2S 9 03 18 FOR POWER SUPPLY AX WARNING T Remove all foreign substances such as dust or water from the power plug terminals and contact points using a dry cloth on a regular basis gt Unplug the power plug and clean it with a dry cloth gt Failure to do so may result in electric shock or fire Plug the power
15. n excluded day 1 When all settings are completed press the Save button 2 Press the button to cancel the setting E1 xl S 2 Ml 01 J1 SOL Touch controller _IB_EN_03944A 1 indd 9 2013 05 28 9 03 20 Functions of Touch Centralized Controller Settings 4 System settings 1 Lock gt Screen Lock You will have to check a password whenever the backlight is turned on with screen lock setting gt Operation Panel Lock You can lock some control items so that other users cannot control the locked items e g A user cannot control the operation mode which you have locked gt Menu Lock A user should be authenticated to use the function of the Touch centralized controller with the menu lock setting When the menu is locked the i will be displayed Password gt Touch Centralized Controller should have the password authentication to operate the functions to which the access of other users is restricted such as tracking system initialization etc 1 Seta password for password authentication 2 The default password is 0000 Indoor Unit options gt Auto mode A user can select the auto mode with auto mode setting If the use of auto mode is locked a user cannot select the auto mode gt Temperature control step You can set the unit of temperature control as 1 0 5 or 0 1 However if the temperature is displayed as Fahrenheit unit the temperature control unit will be fixed as 1 gt Temp
16. rminal DO Use it to output digital signal Indoor unit On Off status Digital input terminal DI 1 DI 2 Use them to connect a device that generates a digital signal e g fire sensor If there is no input to the Touch Centralized Controller for a while it will be turned to screen protection mode nore LCD backlight is turned off Ifyou press the LCD ON OFF button in the screen protection mode the screen protection mode will end Even if the LCD backlight is status off the Touch Centralized Controller is still in operation Ej X S 2t Ml Ol D SOL Touch controller _IB_EN_03944A 1 indd 6 2013 05 28 2S 9 03 19 Functions of Touch Centralized Controller Control and monitoring an Touch centralized controller can control or monitor the control items of connected indoor units Control items Description Remarks m Turn All Off Turn all devices off On Off Turn an indoor unit amp ERV amp DHW on or off Desired temp Control an indoor unit amp desired temp Fan speed Control the fan speed Air direction Control the air direction Mode Control an indoor unit or ERV operation mode Remote Control Control the level of a remote controller Operation mode limit Control exclusive mode Cooling only Heating only No limitation Heat upper limit Limit the maximum desired temperature for heating Cool lower limit Limit the minimum desired temperature for cooling Additional function Control motion det
17. tomized by a user Create a page in the created zone and move the location of a device gt The icon for the zone can also be customized vr vv Oo HSITDN4 Menu of zone list Icon Function Description Moving in T ee TE Ack i aa Move inside the zone The page within the zone and devices within the page will be displayed CA Creatinga Create a zone You can create a maximum of 12 zones The created zone will not be deleted zone arbitrarily unless a user deletes the zone with Ea Deleting a zone Deleting a eae Delete the zone a user has selected If a device is within the zone the zone cannot be deleted 2 Changing an You can change an icon of a zone icon For the detailed explanation of the zone icon refer to legend of control amp monitoring Changing a 9109 You can change the name of a zone zone name Save Save the zone that a user has edited and the formation of devices A user can change the order of a zone with drag amp drop 11 E1 xl S St Ml O1J1 SOL Touch controller _IB_EN_03944A 1 indd 11 2013 05 28 9 03 20 Functions of Touch Centralized Controller Menu within a zone You can create a new page with the beside the page number However the page without an indoor unit will be automatically deleted with saving Icon Function Description You can delete the page which does not have devices Deleting a page A You cannot delete the page that has devices

Download Pdf Manuals