Contents
1. 1 GND 2 GND 3 LED1 4 USB5 5 USB_4 5 OC 6 USB5 7 USB4 8 AD3 3V 0 9 USB4 10 CAN1_RESET 11 5V 12 5V 13 LED2 14 CAN2_RESET 15 AD3 3V 1 16 AD3 3V 2 17 AD3 3V 3 18 AD3 3V 4 19 AD3 3V 5 20 AD3 3V 6 21 AD3 3V 7 22 DIR 23 ALE 24 IOR 25 IOW 26 RESET 27 SW_COM3 28 SW_COM4 29 SW_CAN_1 30 SW_CAN2 31 CSA1 32 CSB1 33 CSA2 34 CSB2 35 CAN_CS1 36 CAN_CS2 37 GND 38 GND 39 INT1 40 INT2 41 INT3 42 LVDS_A 0 43 INT5 44 LVDS_A 0 45 5V 46 5V 47 COM3_ON 48 LVDS_A 1 49 COM3_TE 50 LVDS_A 1 51 GND 52 GND 53 SMBCLK 54 SMBDAT 55 INT4 56 LVDS_A 2 57 INT6 58 LVDS_A 2 59 COM4_ON 60 LVDS_A_CK 61 COM4_TE 62 LVDS_A_CK 63 GND 64 GND 65 GND 66 AC_BITCLK 67 AC_SYNC 68 AC_SDINO 69 AC_SDOUT 70 AC_RST 71 GND 72 GND CPC508 User Manual 17 2012 Fastwel Ver 001 E Functional Description Fastwel EN CPC508 2 1 3 Keyboard Mouse Interface A keyboard and a mouse can be connected to CPC508 using front panel USB sockets CPC508 includes 8042 compatible keyboard controller emulator realized on FPGA 2 1 4 USB Interfaces The CPC508 supports eight USB 2 0 ports Two ports USB1 and USB2 are available on CPC508 front panel via two Type A connectors XS2 and XS3 Two ports USB3 and USB4 are routed to XS6 connector and are available at
2. 20 32 Handle Lock Button 1 6 System Expansion Module To expand system UO capabilities Fastwel offers MIC589 a mezzanine interface expansion module It is designed to be installed on the top right or on the bottom side left of CPC508 processor module and is connected via XS6 connector MIC589 is supplied with the adaptor connector to enable connection to CPC508 The detailed description of expansion module can be found in relevant section of this Manual CPC508 User Manual 13 2012 Fastwel Ver 001 E Functional Description el LE CPC508 Fastw 2 Functional Description 2 1 Module Interfaces 2 1 1 CompactPCl Bus Connectors Figure 2 1 CompactPCI Connectors J1 and J2 gt The CPC508 is designed for a CompactPCI bus architecture Att t but it utilizes only two of standard CompactPCl connectors EENEN J1 and J2 The CompactPCI standard is electrically identical aah to the PCI local bus However these systems are improved to support multiple slots and to operate in harsh industrial EENEN environments J1 stadard CompactPCI connector is marked as XS8 on PD board J2 CompactPCI 2 30 is marked as XS7 2 1 1 1 CompactPCI Connector Color Coding EE Guide lugs on CompactPCI connectors serve to ensure a i correct mating of connectors A proper mating is guaranteed Note GC also by the use of color coded keys for 3 3V and 5V Pinrows hill operation Color co
3. Powered from CPC506 mezzanine connector Mechanical stability Vibration 10 500 Hz 5g Single shock 100g Multiple shock 50g Weight 0 160 kg Dimensions 3U cPCI 131 mm x 210 x 20 32 mm 4HP Operating temperature range 40 C 85 C CPC508 User Manual 44 2012 Fastwel Ver 001 E MIC589 Mezzanine Expansion Module Fastwel EN CPC508 7 4 MIC589 Delivery Checklist The MIC589 supplied set includes 1 7 5 7 5 1 7 5 1 1 O bh O OB Ja MIC589 mezzanine module One jumper for MJ2 2 Six jumpers for MJ 0 A set for linking handles Schroff p n 20817 672 1 package 10 pcs Adapter connector for connection to CPU module Samtec DWM 36 61 G D 496 Two WAGO p n 733 103 connectors Two WAGO p n 733 105 connectors Antistatic bag for MIC589 Consumer package Note xX Keep all the original packaging material antistatic bag and consumer package for future storage or warranty shipments MIC589 Interfaces MIC589 Interfaces List Front Panel 4HP Interfaces The following interfaces are available at the MIC589 front panel 7 5 1 2 COM1 COM2 RS422 485 interfaces 1000 V isolation Two USB 2 0 4 contact sockets USB3 and USB4 type A Two user programmable LEDs CANT CAN ports 1000 V isolation Interfaces Routed to CPCI J2 Connector The following interfaces are routed to CPCI J2 connector a COM1 COM2 RS422 485 without isolation el COM COM4 RS232 interfa
4. Connector 1 P2 5 J6 6 J6 4 PE 3 PE 2 PE 1_PE L PCle signals and clocks SATA control 4 SATA 3_SATA 2_SATA 1_SATA 4 USB2 3 USB2 2_USB2 1_USB2 Connector 1 P2 5 J1 6 J1 7 J1 8 J1 System CPCIPlus CPCIPlus CPCIPlus CPCI Plus Slot Den slot 1 perif slot2 perif slot3 Gent slot 4 CPC508 supports two SATA channels These drives are installed in slots 1 and 2 5 J1 n 6 J1 SATA drives operation in slots 7 J1 and 8 J1 is not supported Fastwel KIC550 or other modules can be used as carrier boards CPC508 User Manual 23 2012 Fastwel Ver 001 E Installation Fastwel Een CPC508 3 Installation The CPC508 is easy to install However it is necessary to follow the procedures and safety regulations below to install the module correctly without damage to the hardware or harm to personnel The installation of the peripheral drivers is described in the accompanying information files For details on installation of an operating system please refer to the relevant software documentation 3 1 Safety Regulations The following safety regulations must be observed when installing or operating the CPC508 Fastwel assumes no responsibility for any damage resulting from infringement of these rules Warning When handling or operating the module special attention should be paid to the heatsink because it can get very hot during operation Do not touch the heatsink when installing or removing the mod
5. Type Drive type selection Auto Auto selection None ATA drive disabled ATAPI Removable IDE Removable removable devices CD ROM CD ROM drive selection Other ATAPI Other ATAPI devices User User selected ATA device parameters Multi Sector Transfers Multi sector data transfers control LBA Mode Control LBA mode control 32 Bit I O 32 bit data transfer mode control Transfer Mode Data transfer mode selection PIO DMA Ultra DMA Mode Ultra DMA mode selection SMART Monitoring S M A R T mode control CPC508 User Manual 31 2012 Fastwel Ver 001 E Phoenix BIOS Setup Fastwel Ley CPC508 5 2 2 SATA Port 1 Port 3 These submenus allow to setup SATA drives parameters SATA Port 1 and SATA Port 3 SATA drives installed in Serial backplane slots SATA Port 2 onboard Fastwel Flash Disk Parameters of these submenus are identical to IDE Primary Master parameters 5 2 3 Memory Cache Figure 5 4 Memory Cache Screen Cache System BIOS area CPC508 User Manual 32 2012 Fastwel Ver 001 E Phoenix BIOS Setup Fastwel Ley CPC508 5 2 4 Boot Features Figure 5 5 Boot Features Boot Features Item Specific Help iDisabl edh Display system Boot time Diagnostic Screen Enabled configuration on boot QuickBoot Mode Enabled Extended Memory Testing None j Enter Summary screen System configuration information screen at startup Boot time Diagnostic Screen Diag
6. 2 3 Figure 2 4 Figure 2 5 Figure 2 6 Figure 2 7 Figure 5 1 Figure 5 2 Figure 5 3 Figure 5 4 Figure 5 5 Figure 5 6 Figure 5 7 Figure 5 8 Figure 5 9 Figure 5 10 Figure 5 11 Figure 5 12 Figure 5 13 Figure 5 14 Figure 5 15 Figure 5 16 Figure 5 17 Figure 7 1 Figure 7 2 Figure 7 3 CPC508 Block Diagrami e sgggedrgegg eeen eege EE KE nec eed ee eee eee 12 CPC508 Module Dimensions and Layout 13 CompactPCI Connectors J1 and J2 3 14 XS6 Expansion Connector for MIC589 Mezzanine Module 17 USB1 XS2 and USB2 XS3 Socket cece ceeeeeeee eee ee eeeeeeeeeeeeeeeeeeaeeeeeeeeeeeeeaeeeeeeeeeeeeeaaees 18 VGA XS1 Front Panel Connector Ethernet Connectors iiicis cate aii Acie eH Mag eee el ange ng ae hee ee CompactFlash SOCK et ciisccescci Sbdswidibeccenptbabancdeheetenpibadesciiegiandibadeuisaedumnpibduceiacheenmblidceepeeediennae Data Storage SuDSYSteMn EE POST Screen tege Eed EES DEEEE EE DEE EE Main Menu Screen e IDE Primary Master Screen 22 eg zosc egtege e gdRdeEEbe getest Ae ee ee gie Memory Cache Screen ies i ed e deefe geed ENEE SE e EE Boot TEE Advanced Menu Green PnP Configuration Submenu Green 34 Intel Menu Screen n CPU Control Submenu Screen Video Intel IGD Control Submenu Screen A 35 ICH Control Sub Menu Green 36 PCI Express Control Submenu Screen 36 ICH USB Control Submenu Screen e Elle EE EE Boot Menu Sree EE Custom MENU SCreen EE Exit Me
7. lanes DVI and eight USB 2 0 channels Modular design allows flexible system configuration thus providing optimum price to performance ratio To expand the functionality of CPC508 the MIC589 mezzanine interface expansion module is used The operational stability of CPC508 make it perfect for use in industrial applications 1 2 Technical Characteristics P Intel processors Low power Atom core integrated memory and graphics controllers Intel Pineview M single core N450 for CPC508 01 Intel Pineview D dual core D510 for CPC508 03 7 IA 32 bit amp 64 bit technology Intel SIMD2 amp 3 SSE2 SSE3 SSSE3 Hyperthreading Technology 2 threads 7 Level 1 cache memory 32 KB instructions 24 KB data Level 2 cache memory 512 KB N450 1 MB D510 Intel SpeedStep Technology E Intel chipset ICH8M a System memory n DDR2 SDRAM 667 MHz w o ECC 1 GB soldered 64 bit addressing a Integrated high performance graphics controller a VGA front panel connector CRT displays support with resolutions of up to 1400x1050 60 Hz for N450 and up to 2048x1536 60 Hz for D510 LVDS interface resolutions up to 1280x800 60 Hz for N450 and 1366x768 60 Hz for D510 single channel 18 bit routed to mezzanine connector available via MIC589 module wi PCI bus Routed to CPCI J1 connector Spec v 2 3 support 32 bit 33 MHz Support for up to 7 bus master devices CPC508 User Manual 8 2012 Fastwel Ver 001 E Introd
8. shipping damages may occur Careful inspection of the shipping carton can reveal evidence of damage or rough handling Should you notice that the package is damaged please notify the shipping service and the manufacturer as soon as possible Retain the damaged packing material for inspection After unpacking the product you should inspect it for visible damage that could have occurred during shipping or unpacking If damage is observed usually in the form of bent component leads or loose socketed components contact Fastwel s official distributor from which you have purchased the product for additional instructions Depending on the severity of the damage the product may even need to be returned to the factory for repair DO NOT apply power to the product if it has visible damage Doing so may cause further possibly irreparable damage as well as result in a fire or electric shock hazard If the product contains socketed components they should be inspected to make sure they are seated fully in their sockets CPC508 User Manual 6 2012 Fastwel Ver 001 E Fastwel Lee CPC508 Handling In performing all necessary installation and application operations please follow only the instructions supplied by the present manual In order to keep Fastwel s warranty you must not change or modify this product in any way other than specifically approved by Fastwel or described in this manual Technical characteristics of the systems in whic
9. 2 Data Storage Subsystem for CPC508 ccc ceeeeeee eee e eee e enna eee eset ee eneeeeeeeeeeeeeciaaeeeeeeeeeeetaeeeeeeeeneed 23 3 Installati EE 24 3 1 Safely Regulators EE 24 3 2 Installation Procedures EE 25 3 3 Removal Procedure 34 Peripheral Devices Installation russis irisan nana anatasa aain aaan iai 26 3 4 1 CompactFlash Cards Installation cccceccceeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeecaeeeeeeeeeeeeeneeeeeeeeneeel 26 3 4 2 USB Devices Installation eeeeeeeeseeeeeeeeeeeeeeeeeeeeeeeeeseseeeeceeeeeeeeeeeeeeeeeeseeeeseeeeeeeeeeeeeees 26 3 4 3 Battery Replacen emtyceicsescccscc8 oi ciaed RAEE RRRA ERRERA AOA AAR AEA AERAR EREEREER 26 3 5 Installation of MIC589 Mezzanine Expansion Module ccccceceeeeeeeeeeeeeeeeeeeceeeeeeeeeeeeeneeeeeeeeeeeeeaaes 27 4 Configuration and Programming e eee REENEN 28 4 1 WDT Operation s z cccciccsecertececsedb seg tat eege Pie een acon econ eee neti WE ere eee 28 4 2 Liser LED Controls coeire crine ekat enni eee eee dae ale et eag eee ghee Lag tate ceed a Ra e aaa 28 5 Phoenix BIOS SetuD 00 iia 29 5 1 StaningG BIOS DI EE 29 52 Main EU EE 30 CPC508 User Manual 1 2012 Fastwel Ver 00141 E Fastwel Lee CPC508 5 2 1 IDE Primary MaSter iczsc d2iseii52c520hee cehncsecohcceed ite ddlechhedencsgui deci E E a SE AAEE eEEEEdE 31 5 2 2 SATA Port 1 POl E EE 32 5 2 3 Memory Epi EE LL Eet 32 5 2 4 Boot TEE 33
10. 9 Advanced MEM UE cae ctstacscceageceq atau aoa chad acageceq atau Daoa Aa DRA DENNER 33 5 3 1 PnP Configuration Submenu eee ee eeeeeeee eee e ee eeeceeeeee eee ee eeeaeeeeeeeeeeeeeaaaeeeeeeeeeeecaaeeeeeeeneeenaaees 34 e Ma ME UE 34 5 4 1 CPU Control SUDMENU eee ceeeeeeeee eee e teen e eee ee eee ee enaeeee eset teen eeaeeeeeeeeeeeeecaaeeeeeeeeeneeeneeeeeeeennees 35 5 4 2 Video Intel IGD Control Guten 35 5 4 3 ICH Control SUBMENU sieht hee Rech des aged ede ec i 36 5 4 3 1 PCI Express Control Guten 36 5 4 3 2 ICH USB Control Gubmenu cect eter ee eee e eter ee eeeenaeeeeeeeeeeeenaeeeeeeeeenees 37 D5 Security MONO spcis ae svcd ea snavnd ache tied deeg EERE dee Ende 37 S6 Boot MEN E 38 Det e Den EE 38 5 7 1 MIG589 e CT 39 ER e 39 6 Additionallinionmati on eee ee eee Te ege ee Eed deer 40 6 1 MV SION POWOM E tn cedteasedsccuetecs Ee 40 7 MIC589 Mezzanine Expansion Module Auen 41 7 1 lui e He 41 T2 WIIG SSS DIAG EE 41 7 2 1 MIC589 Block dp Eier EI 41 7 2 2 MIC589 Connectors Layout vis ccs ch aie ene Ge ee ae eee lee 42 7 2 3 MIC589 Components Layout sc cciccieehiecctnce tenses iacecs tec smedaslaceddcensunedanddlaadcessenabencdcieetensewagauconne 43 23 SPOCHICATIONS EE 44 7 4 MIC589 Delivery Checklist ccc cee eenere ee ee ee eee e eee eee e etna tees eee eeeeaeeeeee eee eeenaeeeeeeeeeneeeiaeeeeeeeeeeed 45 7 5 MIC589 Interface 45 7 5 1 MIC589 Interfaces List 45 7 5 1 1 Fron
11. C508 module design connectors and components layout The diagrams may not reflect insignificant differences between the CPC508 versions wv CPC508 User Manual 11 2012 Fastwel Ver 001 E Introduction Fastwel L CPC508 1 5 1 Block Diagram Figure 1 1 CPC508 Block Diagram Soldered NAND Flash 4GB Soldered SATA NAND DDR2 SDRAM Flash r i 1 GB Controller e eer VGA PineView M Compact ce I CRT l Flash l l l n R I Gigabit An l l Ethernet l 182574 l l i I oes o 8 Gigabit i XS4 Gigabit l Ethernet LAN 1 2 I Multiplexor l l l l l Gigabit 1 XS7 J2 l XS2 l Ethernet i l l l i82574 i l PCIE I PCI E 1 4 X83 l l i l l I 1 USB 5 8 ete eee ee PCI I PCI PCI Bridge 32 bit FC Bus S8 J1 Hardware CK 505 Monitor amp SS SPI BIOS LM87 Clocking 16 Mbit LPC Bus FPGA Supervisor CPU Core VR WDT Chipset VR TTT a j a Memory VR l l HD Link USB 3 4 8 bit Local Power Supply Bus CPC508 User Manual 12 2012 Fastwel Ver 001 E Introduction Fastwel Een CPC508 1 5 2 Module Dimensions and Layout Figure 1 2 CPC508 Module Dimensions and Layout 212 5 Lower Fixing Screw Upper Fixing Screw 130 5 Etht io USB2 USB1 L1
12. CI E bus traffic and a PCI E interface providing efficient bus utilization by increased use of bursts Figure 2 5 Ethernet Connectors Act Link Two RJ45 Gigabit Ethernet connectors are located on CPC508 front panel XS4 The interfaces provide auto detection and switching between 10Base T 100Base TX and 1000Base T operation modes Each of the two Ethernet channels are software switchable to XS7 CPCI J2 PICMG 2 30 to provide system flexibility Table 2 7 Gigabit Ethernet Connectors Pinouts 1 O TX O TX UO BI_DA 2 O TX O TX I O BI_DA 3 l RX l RX UO DI D I A UO BI_DC 5 UO DI DC 6 RX l RX UO BI_DB 7 I O BI_DD 8 I O BI_DD MDI Standard Ethernet Cable Integrated Ethernet LEDs Line green This LED indicates network connection The LED lights up when the line is connected Act green This LED monitors network activity The LED lights up when network packets are sent or received through the RJ45 port When this LED is not lit it means that the computer is not sending or receiving network data CPC508 User Manual 20 2012 Fastwel Ver 001 E Fastwel Lee Functional Description CPC508 2 1 8 SATA Ports Two SATA ports are
13. E GND 12 GND 4 PE_Rx00 1 PE_CLKE 2 PE CLKE a GND 11 GND 4 PE_Rx00 4 PE_Tx00 4 USB2 GND 10 GND 3 PE_Rx00 4 PE_Tx00 A _USB2 GND 9 GND 3 PE_Rx00 3 PE_Tx00 3 USB2 Se Se GND 8 GND 2 PE_Rx00 3 PE_Tx00 3_USB2 2 SATA_Rx GND 7 GND 2 PE_Rx00 2 PE Tx00 2 USB2 2 SATA Txt 2 SATA Rx GND 6 GND 1_PE_Rx00 2 PE _Tx00 2 USB2 2 SATA Tx 1 SATA_Rx GND 5 GND 1_PE_Rx00 1_PE_Tx00 1_USB2 1_SATA Tx 1 SATARx GND 4 GND Ivo 1_PE_Tx00 1_USB2 1_SATA Tx Reserved GND 3 GND CLK4 GND GNT3 REQ4 GNT4 GND 2 GND CLK2 CLK3 SYSEN GNT2 REQ3 GND 1 GND CLK1 GND REQ1 GNT1 REQ2 GND CPC508 User Manual 16 2012 Fastwel Ver 001 E Fastwel Lee CPC508 Functional Description 2 1 2 Connector for Mezzanine Module MIC589 mezzanine module is used to enhance I O capabilities of CPC508 It is installed on the top side to the right of CPC508 processor module or on the bottom side to the left using adapter connector 72 contact XS6 high speed through connector socket is used for connection of MIC589 See description of MIC589 expansion module in the relevant section of this document Figure 2 2 XS6 Expansion Connector for MIC589 Mezzanine Module f 1 oo0o0m0000000000000000000000000000000 2 oo0o000000000000000000000000000000000 1 T T Table 2 4 Pinout of XS6 Connector for MIC589 Mezzanine Module
14. Fastwel LE CPC508 3U CompactPCI CPU Module User Manual Rev 001 E December 2012 The product described in this manual is compliant with all related CE standards Product Title CPC508 Document name CPC508 User Manual Manual version 001 E Ref docs CPC508 UM v1 02 R IMES 467444 062 RE Copyright 2012 Fastwel Co Ltd All rights reserved Revision Record 001 Initial version CPC508 MIC589 December 2012 Contact Information Fastwel Co Ltd Fastwel Corporation US Address 108 Profsoyuznaya st 45 Main Street Suite 319 Moscow 117437 Brooklyn New York 11201 Russian Federation USA Tel 7 495 232 1681 1 718 554 3686 Fax 7 495 232 1654 1 718 797 0600 Toll free 1 877 787 8443 1 877 RURUGGED E mail info fastwel com Web http www fastwel com Fastwel Lee CPC508 Table of Contents f 10 e Of 1 tc Peete ee Pe a ee De ee eee 1 oeoa E ios sic E E E E E EE E 2 List Of le EE 3 Notation Conventions isinira coke SEA eka rete ead ese eae cei deed gained dE eed ened eae eet EE OR EEE EARRA REE 4 General Safety Precautions 2 icc cecececcscncceneeessuececctie cnegeecnee cae etenag ences iaka e en a ahaaa a aaa aeaea aa ae EE EAG 5 Unpacking Inspection and Handling anaa aaaea aa aaa 6 Three Year Warrantv eee eeeeeeeeeaaaaaeeeeeeeneaaaaaaaeeeeeeeaaaaaaaeeeeeeeeaaeaaaeseeeseeeaaaaaeeeesaaaeeeeeeeeeenea 7 1 MEMO AUCTION EE 8 1 1 OV ERVIGW eet asc di
15. JE JE JE JE JE JE JE JE AE FE Fastwel CPC5 8 Platform BIOS v1 29 FE FE HE HE HE HE FE HE JE JE JE JE JE JE JE EE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE JE HH CPU 1 Processors Detected Cores per Processor 2 Intel R Atom TM CPU D518 1 66GHz 1014M System RAM Passed 912 KB L2 Cache per Processor Core System BIOS shadowed Video BIOS shadowed Press lt F2 gt to enter SETUP CPC508 User Manual 29 2012 Fastwel Ver 001 E Phoenix BIOS Setup Fastwel LE CPC508 5 2 Main Menu After pressing F2 the Main Menu screen is shown Figure 5 2 Main Menu Screen System Time j Enter Use lt Up gt and lt Down gt cursor keys or lt Tab gt key to move between menu items Use lt Left gt and lt Right gt keys to move between tabs lt Enter gt selects the item and allows to proceed with the command or opens the submenu screen Use lt Esc gt key to exit submenu To change values in the selected item use lt gt and lt gt on the numeric keypad This legend applies to all other tabs in BIOS Setup CPC508 User Manual 30 2012 Fastwel Ver 001 E Phoenix BIOS Setup Fastwel Ley CPC508 5 2 1 IDE Primary Master This submenu allows to set parameters of IDE drive CompactFlash is IDE Primary Master device Ha pucyHKe Hnxe noka3aH BUA KpaHa NogMeHto IDE Primary Mastem Figure 5 3 IDE Primary Master Screen
16. MIC589 mezzanine module Four USB ports USB5 USB8 are routed to J2 CompactPCI connector PICMG 2 30 of CPC508 Figure 2 3 USB1 XS2 and USB2 XS3 Sockets 123 4 All ports support high speed full speed and low speed operation Hi speed USB 2 0 supports data transfer rate of up to 480 Mb s than eight USB devices use an external hub One USB device may be connected to each port To connect more The USB power supply is protected by a self resettable 500 mA fuse Table 2 5 USB1 and USB2 Pinouts CPC508 Front Panel 1 VCC VCC signal 2 UVO Differential USB 3 UVO Differential USB 4 GND GND signal CPC508 User Manual 18 2012 Fastwel Ver 001 E Functional Description Fastwel LBs CPC508 2 1 5 Graphics Controller A highly integrated 2D 3D graphics accelerator is included in the CPU The internal graphics controller provides interfaces to a standard analog monitor VGA connector on CPC508 front panel or and to digital displays Dual monitor clone extended desktop configurations are supported 2 1 5 1 VGA Interface and Connector Figure 2 4 VGA XS1 Front Panel Connector The 15 pin female D Sub connector XS1 on CPC508 front panel is used to connect a CRT monitor to the CPC508 module Resolutions CPC508 01 up to 1400x1050 60 Hz CPC508 03 up to 2048x1536 60 Hz Its pinout is in the ta
17. PCI Express Port via this setup option Disabled Port always disabled Only enable if card Auto found Note that if Root Port 1 is disabled Root Ports 2 4 will be disabled as well CPC508 User Manual 36 2012 Fastwel Ver 001 E Phoenix BIOS Setup Fastwel EN CPC508 5 4 3 2 ICH USB Control Submenu Figure 5 13 ICH USB Control Submenu Screen ICH USB Control Sub Menu Item Specific Help fun au 173 A Controls Dev 29 USB Dev 26 Fun 0 1 7 Overcurrent Detection Enabled ay Enter TBA 5 5 Security Menu Figure 5 14 Security Menu Screen Main Advanced Intel Security Boot Custom Exit Item Specific Help Supervisor Password Is Clear ser Password Is Clear Write protects boot Set Supervisor Password Enter sector on hard disk Set User Password Enter to protect against viruses Normal Virus check reminder Disabled Password on boot Disabled Enter TBA CPC508 User Manual 37 2012 Fastwel Ver 001 E Phoenix BIOS Setup Fastwel LE CPC508 5 6 Boot Menu Figure 5 15 Boot Menu Screen Main Advanced Intel Securit Custom Exit Item Specific Help Keys used to view or configure devices Up and Down arrows select a device lt gt and lt gt moves the device up or down lt f gt and lt r gt specifies Excluded from boot order the device fixed or All IDE HDD removable Floppy lt x gt exclude or include EN the device t
18. Specification 2 0 Rev 3 0 CompactPCI PluslO PICMG 2 30 CPC508 User Manual 46 2012 Fastwel Ver 001 E Useful Abbreviations Acronyms and Short cuts Fastwel Les CPC508 9 Useful Abbreviations Acronyms and Short cuts BMC Baseboard Management Controller PM Peripheral Management Controller IPMI Intelligent Platform Management Interface IPMB Intelligent Platform Management Bus ro Inter Integrated Circuit Two thread serial protocol used in SMB and IPMI KCS interface Keyboard Controller Style interface Interface for communication between control software and BMC similar to a keyboard controller interface BT interface Block Transfer interface Block transfer interface for communication between control software and BMC DDR SDRAM Double Data Rate Synchronous Dynamic Random Access Memory SODIMM Small Outline Dual In Line Memory Module ECC Error Correction Code Data error correction technology used in memory modules FWH Firmware Hub Nonvolatile memory chip part of Intel chipset used for main and reserve BIOS copies in CPC508 GMCH Graphics and Memory Controller Hub DAC Digital Analog Converter USB Universal Serial Bus LPC Low Pin Count External devices communication interface SMB System Management Bus UART Universal Asynchronous Receiver Transmitter UHCI Universal Host Controller Interface USB Host Controller Interface EHCI Enhan
19. T les en eu DT ADR 7 XP41 La XPI Li S IN ES ES XP39 XP42 gt XS1 N a XP15 g XS2 Ed 1 Lower Retaining Screw Upper Retaining Screw 131 La Handle Button USB3 USB4 CANT CAN2 SERIAL1 SERIAL2 KE E E D H Q ei Q 0 ER aq i a Leen E S gt OO naan 20 32 RS422 RS485 The module s components layout may slightly differ for various versions of the module CPC508 User Manual 43 2012 Fastwel Ver 001 E MIC589 Mezzanine Expansion Module Fastwel EN CPC508 7 3 Specifications Audio controller High Definition Audio compatible codec Line In Line Out and Mic In interfaces are routed to CPCI J2 LVDS Routed from mezzanine connector to CPCI J2 18 bit Two USB ports Conform to USB 2 0 specification Front panel connectors Routed from CPC506 via mezzanine connector Four serial ports COM COM 1000 V isolated RS 422 485 ports front panel connectors without isolation and transceivers switched to CPCI J2 COM3 COM non isolated RS 232 ports CPCI J2 CAN interfaces CAN1 and CAN2 available at front panel 1000 V isolation without isolation and transceivers switched to CPCI J2 LEDs Two programmable user LEDs at front panel Does not require forced air cooling MTBF not less than 730000 hours Power 5V4 5 0 3A
20. V PAR C BE 1 GND 17 GND 3 3V IPMB_SCL IPMB_SDA LNG_GND PERR GND 16 GND DEVSEL GND VIO STOP LOCK GND 15 GND 3 3V FRAME IRDY SHRT_GND TRDY GND 14 GND GND 13 GND Key Area GND 12 GND GND 11 GND AD 18 AD 17 AD 16 LNG_GND C BE 2 GND 10 GND AD 21 GND 3 3V AD 20 AD 19 GND 9 GND C BE 3 SHRT_GND AD 23 LNG_GND AD 22 GND 8 GND AD 26 GND VIO AD 25 AD 24 GND 7 GND AD 30 AD 29 AD 28 LNG_GND AD 27 GND 6 GND REQO GND LNG_3 3V CLKO AD 31 GND 5 GND BRSVP1A5 BRSVP1B5 RST LNG_GND GNTO GND 4 GND IPMB_PWR HEALTHY LNG_VIO INTP INTS GND 3 GND INTA INTB INTC LNG_5V INTD GND 2 GND TCK 5V TMS TDO TDI GND 1 GND 5V 12V TRST 12V 5V GND CPC508 User Manual 15 2012 Fastwel Ver 001 E Functional Description Fastwel Lee CPC508 Table 2 3 32 bit CompactPCI Bus Connector J2 XS7 System Slot Pinout 22 GND GA4 GA3 GA2 GA GAO GND 21 GND CLK6 GND 2 ETH B 1_ETH_D 1_ETH_B GND 20 GND CLK5 GND 2 ETH B 1_ETH_D 1_ETH_B GND 19 GND GND GND 2_ETH_A 1_ETH_C 1_ETH_A GND 18 GND 2 ETH_D 2 ETH C 2 ETH A 1_ETH_C 1_ETH_A GND 17 GND 2 ETH _D 2 ETH C PRST REQ6 GNT6 GND 16 GND 4 PE CLK 2 PE_CLK DEG GND Reserved GND 15 GND 4 PE_CLK 2 PE_CLK FAL REQ5 GNT5 GND 14 GND 3 PE CLK 1_PE_CLK 4 PE_CLKE Reserved GND 13 GND 3 PE_CLK 1_PE_CLKk 3 PE_CLK
21. astwel Ver 001 E Introduction Fastwel Een CPC508 D Mezzanine connector e Used for connection of MIC589 interface expansion module HD Audio two USB ports LVDS 8 bit local bus Weight 0 450 kg max Dimensions 130 5 mm x 213 0 mm x 20 32 mm Power voltage 5 V 5 from CPCI connector Consumption current 7 CPC508 01 2 8 A g CPC508 03 3 1 A MTBF 140000 hours a OS compatibility FreeDOS Windows XP Embedded n Linux 2 6 g QNX 6 5 1 3 CPC508 Versions CPC508 is available in two versions Dee hae 1 Basic product name CPC508 2 Version 01 Intel Pineview M N450 03 Intel Pineview D D510 3 Operating temperature range l Industrial 40 C 85 C 4 Other options Coating COATED Protective coating Operating System XPE Windows XP Embedded LNX Linux 2 6 CPC508 User Manual 10 2012 Fastwel Ver 001 E Introduction Fastwel L CPC508 1 4 Delivery Checklist The CPC508 delivery set includes 1 5 1 2 3 CPC508 processor module MIC 23008 CompactFlash memory module with preinstalled Windows XPe only if XPE option is selected Antistatic bag Consumer carton box 230x155x45 mm gross weight 0 650 kg max Note xX Keep the antistatic bag and the original package at least until the warranty period is over It can be used for future storage or warranty shipments CPC508 Diagrams The diagrams in this section give visual information about the CP
22. ata 14 In Out 31 D15 Data 15 In Out 32 IDE_CS1 Chip select 1 Out 33 VS1 34 IORD UO read Out 35 IOWR UO write Out 36 3 3 V WE 3 3 V power CPC508 User Manual 21 2012 Fastwel Ver 001 E Functional Description Fastwel EN CPC508 37 INTRQ Interrupt In 38 3 3 V 3 3 V power 39 CSEL Master Slave Out 40 VS2 41 Reset Reset Out 42 IORDY UO ready In 43 INPACK DMA Request Out 44 REG DMA Acknowledge 45 ACTIVE IDE Activity 46 PDIAG DMA Mode Detect 47 D08 Data 08 In Out 48 D09 Data 09 In Out 49 D10 Data 10 In Out 50 GND 2 1 11 LED Indicators L1 and L2 There are two LED indicators at the front panel L1 and L2 described in the tablebelow Table 2 8 L1 and L2 LEDs Functions L1 Power indicator Green After switching power on lights green Also can user LED be controlled via LED1_EN bit as user LED Red Can be controlled via LED2_EN bit as user LED L2 Drives activity indicator Green SATA NAND and Flash drives activity CPC508 User Manual 22 2012 Fastwel Ver 001 E Functional Description Fastwel Lee CPC508 2 2 Data Storage Subsystem for CPC508 According to PICMG 2 30 specification CPC508 supports data storage devices installed in Serial backplane slots Slot names 1_SATA 4_ SATA are shown in the figure below Figure 2 7 Data Storage Subsystem WE 2 ETH 2 DP 1_ETH 1 DP
23. ble below Table 2 6 VGA XS1 Front Panel Connector Pinout a a ee 1 Red Red video signal output Out 2 Green Green video signal output Out 3 Blue Blue video signal output Out 12 DDCdata IC data In Out 13 Hsync Horizontal sync TTL out 14 Vsync Vertical sync TTL out 15 DDCclk IC clock Out 5 6 7 8 10 GND Signal ground 4 11 9 NC 2 1 5 2 LVDS Interface LVDS is routed to XS6 mezzanine connector to be available at MIC589 expansion module Single channel LVDS mode is supported up to 18 bit pixel 25 112 MHZ LCD panels LVDS 18 bit are supported with following resolutions CPC508 01 1280x800 60 Hz CPC508 03 1366x768 60 Hz CPC508 User Manual 19 2012 Fastwel Ver 001 E Functional Description Fastwel EN CPC508 2 1 6 Serial Interfaces RS232 and RS422 485 Serial interfaces are available only if MIC589 interface expansion module is installed There are four serial ports available via MIC589 connectors and on backplane via CPCI J2 connector of MIC589 See details in the relevant section of this document 2 1 7 Gigabit Ethernet The CPC508 board includes two 10Base T 100Base TX 1000Base T Ethernet ports based on Intel 82574L Gigabit Ethernet PCI E bus controllers The Intel 82574L Gigabit Ethernet controller architecture combines high performance and low power consumption The controller s features include independent transmit and receive queues to limit P
24. ce oe ae dared oa de da eet dee deiere A E 8 1 2 Technical Characteristics ccccecceeeeee eee e ener e eee eee e tne ee eee sere ee ecaeeee sees eeeeaaeeeeeeeeeeeeaaeeeeseseaeeeeesereneeeaaed 8 1 3 CPC508 Version 10 1 4 Delivery Checklistscc i4 2hh eee aiid sae eek eee ie Bee ie 11 1 57 CPC508 RL TE EE 11 1 5 1 Block Dla TEE 12 1 5 2 Module Dimensions and Layout 13 1 6 System Expansion Module sete eecneeeeeee eee eecaaeeeeeeeeeeeecaaeeeeeeeeeeeeeaeeeeeeeeeeenenaaeneeess 13 2 Functional AT e LE 14 2 1 Module Interfaces geneet eer eege EE Eed eech 14 2 1 1 CompactPCI Bus Connectors eimino ariora ara eaaa aaaea a rE a a aaae oeaan 14 2 1 1 1 CompactPCI Connector Color Codng 14 2 1 1 2 CompactPCI Connectors J1 and J2 Pinouts cece ceceeeeee eee eeeeeeeeeeeeeeeeeeeeeeeeeees 15 2 1 2 Connector for Mezzanine Module 17 2 1 3 Keyboard Mouse Intertace seisine e aean nen ENEE wc REEE RAEN ERER 18 2 1 4 Hoer eege anaa ea A RE deed E E E RA E nai ERR iiit 18 2 1 5 Graphics Controller sesatostdiroe isnon aeaaaee ia ae a A eaae i Raae 19 2 1 5 1 WGA Interface and Conmechr een 19 2 1 5 2 LVDS Interface AAA 19 2 1 6 Serial Interfaces RS232 and RGA2IADE eee eeeeeeteeeeee eee eeecaeeeeeeeeeeeenaaeeeeeeeenees 20 2 1 7 Gigabit Ethernet AAA 20 2 1 8 SATA PONSE e cee eee svosse cts cces tava vaste EE 21 2 1 9 FID AU GIO EE 21 2 1 10 CompactFlash Socket 22 20 44 sshanect ne Anne GRR a aes 21 2 1 11 LED Indicators L1 and L2 EEN 22 2
25. ced Host Controller Interface Universal Serial Bus specification UTP Unshielded Twisted Pair CRT display Cathode Ray Tube Display PMC PCI Peripheral Component Interconnect Mezzanine Card CMC Common Mezzanine Card LVDS Low Voltage Differential Signal Digital monitors communication specification RTC Real Time Clock BIOS Basic Input Output System PC Personal Computer PICMG PCI Industrial Computer Manufacturers Group AHA Accelerated Hub Architecture GMCH and ICH communication bus specification CPC508 User Manual 47 2012 Fastwel Ver 001 E Useful Abbreviations Acronyms and Short cuts Fastwel Lee CPC508 AGP Accelerated Graphics Port AGTL Advanced Gunning Transceiver Logic PSB Processor Side Bus signal exchange specification SMBus System Management Bus EEPROM Electrically Erasable Programmable Read Only Memory NAND Flash Not And electronic logic gate Flash memory specification SSD Solid State Disk PLCC Plastic Leaded Chip Carrier RAMDAC Random Access Memory Digital to Analog Converter DAC Digital to Analog Converter DVMT Dynamic Video Memory Technology TTL Transistor Transistor Logic ECP EPP Extended Capabilities Port Enhanced Parallel Port Parallel port specifications FDD Floppy Disk Drive EIDE Enhanced Integrated Drive Electronics Mass storage devices interface DMA Direct Memory Access PIO Programmed Input Output EIDE Directly processor controlled data ex
26. ces without isolation Audio interface Line In Line Out Mic In a CANT CAN2 without isolation Gi LVDS 18 bit TBA CPC508 User Manual 45 2012 Fastwel Ver 001 E Supplementary Information Fastwel LBs CPC508 8 Supplementary Information 8 1 Related Standards and Specifications The Fastwel s CompactPCI modules comply with the requirements of the following standards Table 8 1 Related Standards CE Emission EN50081 1 CE Immission EN61000 6 2 CE Electrical safety EN60950 2002 Mechanical dimensions IEEE 1101 10 Vibration sinusoidal IEC60068 2 6 82 Fc 5 g 10 500 Hz 10 acceleration frequency range test cycles per axis Permanent shock IEC60068 2 29 87 Eb 50 g 11 ms 1000 10 1s peak acceleration shock duration half sine number of shocks recovery time Single shock IEC60068 2 27 87 Ea 100g 9ms 18 3s peak acceleration shock duration number of shocks recovery time in seconds Important Some versions of the module may have the test results differing from the ones presented in the above table For more information please contact Fastwel s official representatives Extreme vibration conditions may require additional fixing of USB devices for example using compound Information related to this product and its components can be found in the following specifications Table 8 2 Related Specifications CompactPCI Systems and Boards CompactPCI
27. change Rear UO Board Rear Input Output Board Auxiliary interface board which is connected to the cPCI backplane rear connectors PWM output Pulse Width Modulation Cooling fan control technique ESD Electrostatically Sensitive Device Electrostatic Discharge ACPI Advanced Configuration and Power Interface POST Power On Self Test cPCI CompactPCI Industrial automation systems standard EOS Electrical Overstress MDI Media Dependent Interface Interface with connection type automatical detection CPC508 User Manual 48 2012 Fastwel Ver 001 E
28. components E If the product contains batteries for RTC or memory back up ensure that the module is not placed on conductive surfaces including anti static mats or sponges This can cause short circuit and result in damage to the battery and other components m Store this product in its protective packaging while it is not used for operational purposes Unpacking The product is carefully packed in an antistatic bag and in a carton box to protect it against possible damage and harmful influence during shipping Unpack the product indoors only at a temperature not less than 15 C and relative humidity not more than 70 Please note that if the product was exposed to the temperatures below 0 C for a long time it is necessary to keep it at normal conditions for at least 24 hours before unpacking Do not keep the product close to a heat source Following ESD precautions carefully take the product out of the shipping carton box Proper handling of the product is critical to ensure correct operation and long term reliability When unpacking the product and whenever handling it thereafter be sure to hold the module preferably by the front panel card edges or ejector handles Avoid touching the components and connectors Retain all original packaging at least until the warranty period is over You may need it for shipments or for storage of the product Initial Inspection Although the product is carefully packaged it is still possible that
29. cts is 36 months since the date of purchase The warranty set forth above does not extend to and shall not apply to 1 Products including software which have been repaired or altered by other than Fastwel personnel unless Buyer has properly altered or repaired the products in accordance with procedures previously approved in writing by Fastwel 2 Products which have been subject to power supply reversal misuse neglect accident or improper installation Returning a product for repair 1 Apply to Fastwel company or to any of the Fastwel s official representatives for the Product Return Authorization 2 Attach a failure inspection report with a product to be returned in the form accepted by customer with a description of the failure circumstances and symptoms 3 Carefully package the product in the antistatic bag in which the product had been supplied Failure to package in antistatic material will VOID all warranties Then package the product in a safe container for shipping 4 The customer pays for shipping the product to Fastwel or to an official Fastwel representative or dealer CPC508 User Manual 7 2012 Fastwel Ver 001 E Introduction Fastwel Een CPC508 1 Introduction 1 1 Overview The product described in this Manual is CPC508 a 3U CompactPCI PluslO PICMG 2 30 CPU module For high speed data exchange CPC508 employs 32 bit PCI bus together with two Gigabit Ethernet channels four x1 PCI Express
30. d RS 485 ei ix RS 485 422 422 isolated CPCI J2 Connector LVDS 18 Bit ap Line In AUDIO S Line Out Let Mir 2x UART RS 232 Leef COM4 Mezz Connector XR16C2850IM Exar RS 232 COM3 LED1 LED2 UART2 2x UART q Switc COM XR16C2850IM UART1 Switch COM1 8 USB3 CANT S CAN S Swi SJA1000T ae Philips CAN2 CAN2 gt Switch SJA1000T Philips CAN GANG Isolated CAN Isolated 1 CAN1 TBA CPC508 User Manual 41 2012 Fastwel Ver 00141 E Fastwel 7 CPC508 User Manual 42 MIC589 Mezzanine Expansion Module CPC508 MIC589 Connectors Layout Figure 7 2 MIC589 Connectors Layout SERIAL2 isolated RS485 422 CPCI J2 SERIAL1 isolated RS485 422 CAN2 isolated U0 oo CAN1 on isolated USB4 DRM USB3 The module s components layout may slightly differ for various versions of the module 2012 Fastwel Ver 001 E MIC589 Mezzanine Expansion Module Fastwel LBs CPC508 7 2 3 MIC589 Components Layout Figure 7 3 MIC589 Components Layout and Dimensions Top XS4 XS3 XP10 XP9 XPT ADR ECCE THI CCEE TEE
31. ded keys prevent accidental installation of ES 22 sees J2 in N On T F T T T J1 z D D D D F and Z a 5V module into a 3 3V slot CompactPCI backplane GND pins connectors keying depends always on the signaling VIO level On universal backplanes supporting both sinalling levels VIO level is selected by a jumper on the backplane CPC508 is a universal module with 3 3V or 5V signalling voltage level Coding key colors are described below Table 2 1 CompactPCI Connector Coding Colors 3 3 V Cadmium Yellow 5V Brilliant Blue Universal module 5V and 3 3V None CompactPCI connector pinouts appear on the following pages CPC508 User Manual 14 2012 Fastwel Ver 001 E Functional Description Fastwel Lee CPC508 2 1 1 2 CompactPCI Connectors J1 and J2 Pinouts CPC508 is equipped with two 2x2 mm pitch female CompactPCI bus connectors J1 XS8 and J2 XS7 Table 2 2 CompactPCI Bus Connector J1 XS8 System Slot Pinout 25 GND 5V REQ64 ENUM 3 3V 5V GND 24 GND AD 1 5V LNG_VIO AD 0 ACK64 GND 23 GND 3 3V AD 4 AD 3 LNG_5V AD 2 GND 22 GND AD 7 GND LNG_3 3V AD 6 AD 5 GND 21 GND 3 3V AD 9 AD 8 M66EN C BE O GND 20 GND AD 12 GND VIO AD 11 AD 10 GND 19 GND 3 3V AD 15 AD 14 LNG_GND AD 13 GND 18 GND SERR GND 3 3
32. ds which has been initialized and formatted in this module By default CPC508 utilizes LBA mode Utilization of CompactFlash cards which has been initialized and formatted in another mode may lead to errors in operation of the module 3 4 2 USB Devices Installation The CPC508 can accept Plug amp Play connection of USB 2 0 computer peripheral devices printers keyboards mice etc All USB devices may be connected or disconnected while the host power is on 3 4 3 Battery Replacement The lithium battery must be replaced with Panasonic BR2032 or a battery with similar characteristics The expected life of a 190 mAh battery in case of operation for 8 hours a day at 30 C is about 5 years However this typical value may vary because battery life depends on the operating temperature and the shutdown time of the system in which the battery is installed CPC508 User Manual 26 2012 Fastwel Ver 001 E Installation Fastwel Lee CPC508 A A Note It is recommended to replace the battery after approximately 4 years to be sure it is operational Important Replacing the battery make sure the polarity is correct up Dispose of used batteries according to the local regulations 3 5 Installation of MIC589 Mezzanine Expansion Module Installation of MIC589 mezzanine expansion module on CPC508 is described in relevant section of this document CPC508 User Manual 27 2012 Fastwel Ver 00141 E Configura
33. ed by this symbol is essential for human and equipment safety Read this information attentively be watchful Note This symbol and title marks important information to be read attentively for your own benefit SE gt b gt CPC508 User Manual 4 2012 Fastwel Ver 001 E Fastwel Lee CPC508 General Safety Precautions This product was developed for fault free operation Its design provides conformance to all related safety requirements However the life of this product can be seriously shortened by improper handling and incorrect operation That is why it is necessary to follow general safety and operational instructions below A A amp Warning All operations on this device must be carried out by sufficiently skilled personnel only Warning When handling this product special care must be taken not to hit the heatsink if installed against another rigid object Also be careful not to drop the product since this may cause damage to the heatsink CPU or other sensitive components as well Please keep in mind that any physical damage to this product is not covered under warranty Note This product is guaranteed to operate within the published temperature ranges and relevant conditions However prolonged operation near the maximum temperature is not recommended by Fastwel or by electronic chip manufacturers due to thermal stress related failure mechanisms These mechanisms are common to all silico
34. ernal devices are 5 V 2 8 A CPC508 01 or 3 1 A CPC508 03 Power supplies to be used with the CPC508 should comply with these requirements Input power connections to the backplane itself should provide minimum power loss Avoid using long input lines low carrying capacity cables high resistance connections To select the appropriate system power supply it is necessary to consider the CPC508 own power consumption the consumption of the other system components possible variations of power consumption during operation e g due to temperature changes and some reserve CPC508 User Manual 40 2012 Fastwel Ver 00141 E MIC589 Mezzanine Expansion Module Fastwel LE CPC508 7 MIC589 Mezzanine Expansion Module 7 1 Introduction MIC589 mezzanine expansion module is designed for installation on Fastwel s CPC506 CompactPCI 3U processor module This mezzanine I O module expands functionality and I O capability of the CPC506 MIC589 module is installed on the top or on bottom side of the CPC506 processor module and connected via the adapter connector 7 2 MIC589 Diagrams The figures in this section are supposed to help you to locate and identify the module s components and connectors Our constant efforts in improving our products may result in minor differences between the real module and its depictions 7 2 1 MIC589 Block Diagram Figure 7 1 MIC589 Block Diagram Front Panel RS 485 ss RS 485 422 422 isolate
35. h this product is installed such as operating temperature ranges and power supply parameters should conform to the requirements stated by this document Retain all the original packaging you will need it to pack the product for shipping in warranty cases or for safe storage Please pack the product for transportation in the way it was packed by the supplier When handling the product please remember that the module its components and connectors require delicate care Always keep in mind the ESD sensitivity of the product Three Year Warranty Fastwel Co Ltd Fastwel warrants that its standard hardware products will be free from defects in materials and workmanship under normal use and service for the currently established warranty period Fastwel s only responsibility under this warranty is at its option to replace or repair any defective component part of such products free of charge Fastwel neither assumes nor authorizes any other liability in connection with the sale installation or use of its products Fastwel shall have no liability for direct or consequential damages of any kind arising out of sale delay in delivery installation or use of its products If a product should fail through Fastwel s fault during the warranty period it will be repaired free of charge For out of warranty repairs the customer will be invoiced for repair charges at current standard labor and materials rates Warranty period for Fastwel produ
36. n Scree i Sieg eene ege aaka anae aaa ia ae n iee raaa iea ara MIC589 Block Diagor am MIC589 Connectors Layout MIC589 Components Layout and Dimensions Top 43 All information in this document is provided for reference only with no warranty of its suitability for any specific purpose This information has been thoroughly checked and is believed to be entirely reliable and consistent with the product that it describes However Fastwel accepts no responsibility for inaccuracies omissions or their consequences as well as liability arising from the use or application of any product or example described in this document Fastwel Co Ltd reserves the right to change modify and improve this document or the products described in it at Fastwel s discretion without further notice Software described in this document is provided on an as is basis without warranty Fastwel assumes no liability for consequential or incidental damages originated by the use of his software This document contains information which is property of Fastwel Co Ltd It is not allowed to reproduce it or transmit by any means to translate the document or to convert it to any electronic form in full or in parts without antecedent written approval of Fastwel Co Ltd or one of its officially authorized agents Fastwel and Fastwel logo are trademarks owned by Fastwel Co Ltd Moscow Russian Federation CompactPCl is a trademark of the PCI industrial Com
37. n devices they can reduce the MTBF of the product by increasing the failure probability Prolonged operation at the lower limits of the temperature ranges has no limitations Caution Electric Shock Before installing this product into a system and before installing other devices on it always ensure that your mains power is switched off Always disconnect external power supply cables during all handling and maintenance operations with this module to avoid serious danger of electrical shock CPC508 User Manual 5 2012 Fastwel Ver 001 E Fastwel Lee CPC508 Unpacking Inspection and Handling Please read the manual carefully before unpacking the module or mounting the device into your system Keep in mind the following ESD Sensitive Device A Electronic modules and their components are sensitive to static electricity Even a non perceptible by human being static discharge can be sufficient to destroy or degrade a component s operation Therefore all handling operations and inspections of this product must be performed with due care in order to keep product integrity and operability a Preferably unpack or pack this product only at EOS ESD safe workplaces Otherwise it is important to be electrically discharged before touching the product This can be done by touching a metal part of your system case with your hand or tool It is particularly important to observe anti static precautions when setting jumpers or replacing
38. nostic screen at startup QuickBoot Mode Quick boot enable disable allows to skip some tests Extended Memory Testing Extended memory check mode selection 5 3 Advanced Menu Figure 5 6 Advanced Menu Screen Advanced Intel Securit Boot Custom Exit Item Specific Help K eck o Reset Configuration Data I Large Disk Access Mode DOS Select the operating system installed gt PnP Configuration on your system which you will use most Port 80h Cycles LPC Bus commonly Legacy USB Support Enabled Note An incorrect setting can cause some operating systems to display unexpected behavior Enter TBA CPC508 User Manual 33 2012 Fastwel Ver 001 E Fastwel Lee Phoenix BIOS Setup CPC508 5 3 1 PnP Configuration Submenu Figure 5 7 PnP Configuration Submenu Screen Advanced gt PCIZPNP ISA IRQ Resource Exclusion TBA 5 4 Intel Menu Figure 5 8 Intel Menu Screen Hain Advanced Boot PnP Configuration Item Specific Help Reserve specific upper memory blocks for use by legacy ISA devices Custom Exit gt Video Intel IGD Control Sub Menu gt ICH Control Sub Menu Enter TBA Item Specific Help These items control various CPU parameters CPC508 User Manual 34 2012 Fastwel Ver 001 E Phoenix BIOS Setup Fastwel LBs CPC508 5 4 1 CPU Control Submenu Figure 5 9 CPU Control Submenu Screen CPU Control Sub Menu Item Specific Hel
39. nsure that the system power is switched off before proceeding Disconnect all cables that may be connected to the module Unscrew the front panel retaining screws ae Se ZS Unlock the module ejection handle s by pressing the integrated button s and then press on the handle s until the module connectors are disconnected from the backplane D Carefully pull the module out of the slot Do not touch the heatsink since it can get very hot during operation CPC508 User Manual 25 2012 Fastwel Ver 001 E Installation Fastwel L CPC508 7 Dispose of the module at your discretion The module should not be placed on any surface or in any form of package until the board and the heatsink have cooled down to room temperature 3 4 Peripheral Devices Installation A lot of peripheral devices can be connected to the CPC508 Their installation procedures differ significantly Therefore the following sections provide mainly general guidelines regarding installation of peripheral devices 3 4 1 CompactFlash Cards Installation CompactFlash socket of CPC508 supports CompactFlash Type UI cards with operating voltage of 3 3 V Attention A Installation of CompactFlash cards while the system power is on can damage the system Carefully slide in the correctly oriented card and gently press to engage the contacts completely Please remember that the heatsink may be hot after operation Note xX It is recommended to use CompactFlash car
40. o boot lt Shift 1 gt enables or disables a device lt 1 amp Loads default boot sequence Boot priority order TBA 5 7 Custom Menu Figure 5 16 Custom Menu Screen Main Advanced Intel Securit Item Specific Help Gigabit Ethernet LAN1 Enabled Direction Front Gigabit Ethernet LAN2 ee Direction Front gt MIC589 peripheral TBA CPC508 User Manual 38 2012 Fastwel Ver 001 E Phoenix BIOS Setup Fastwel Le CPC508 5 7 1 MIC589 Peripheral Available if MIC589 is installed 5 8 Exit Menu Figure 5 17 Exit Menu Screen Exit Saving Changes TBA CPC508 User Manual 39 2012 Fastwel Ver 001 E Additional Information Fastwel Ee CPC508 6 Additional Information 6 1 System Power CPC508 uses 5V 5 from CPCI backplane The CPC508 module itself has been designed to provide best possible power supply for each system unit However in order to guarantee reliable and faultless operation the following requirements must be taken into account Absolute maximum input voltages presented in the table below must not be exceeded to guarantee that the CPC508 is not damaged The ranges for the different input power voltages within which the module is functional are also presented Table 6 1 DC Input Voltage Ranges and Limits 5 5 5 4 75 to 5 25 Nominal voltage transition time of the power supply should not exceed 200 ms Consumption currents for CPC508 int
41. or the installation of CPC508 specific peripheral devices and I O devices refer to the appropriate sections in Chapter 3 For details on installation of expansion modules refer to respective sections of this document 3 If the module is intended for operation with a mezzanine module install the mezzanine module following corresponding instructions 4 To install the CPC508 Make sure that no power is connected to the system 2 Avoiding contact with other modules of the system carefully insert the module into the chosen slot until it contacts the backplane connectors Do not apply force pushing the module into the backplane connectors 3 Using the front panel ejector handle handles engage the module with the backplane The module is completely engaged when the ejector handle is locked If the mezzanine module is installed ensure simultaneous locking of both handles Fix the module with the front panel retaining screws Connect the required external interfacing cables to the module s connectors and make sure that the module and all connected cables are properly fixed The CPC508 is now ready for operation Please refer to appropriate software application and system manuals to get further instructions 3 3 Removal Procedure To remove the module from the system case do the following 1 When performing the next actions keep to safety regulations of the Section 3 1 Pay special attention to the temperature of the heatsink E
42. p lEnabledi Enabling Hyper threading Processor Power Management GY3 Only activates additional CPU threads These No Execute Mode Mem Protection Enabled threads may appear as Set Max Ext CPUID 3 Disabled additional processors but will share some resources with the other threads within the physical package j Enter TBA 5 4 2 Video Intel IGD Control Submenu Figure 5 10 Video Intel IGD Control Submenu Screen Video Intel IGD Control Sub Menu Item Specific Help These items control Default Primary Video Adapter Auto various LCD parameters IGD Device 2 Auto IGD Device 2 Function 1 Auto DYHT 4 0 Mode Auto DYHT Graphics Memory 376MB T Enter TBA CPC508 User Manual 35 2012 Fastwel Ver 001 E Phoenix BIOS Setup Fastwel Lee CPC508 5 4 3 Figure 5 11 ICH Control Submenu ICH Control Sub Menu Screen Integrated Device Control Sub Menu_ gt ICH USB Control Sub Menu Azalia Device 27 Function H AHCI Configuration Disable Vacant Ports Auto Disabled Disabled TBA 5 4 3 1 PCI Express Control Submenu Figure 5 12 PCI Express Control Submenu Screen TBA Item Specific Help These items control various ICH PCI Express Devices PCI Express Control Sub Menu Item Specific Help PCI Express Root Port 2 PCI Express Root Port 3 PCI Express Root Port A foto Auto Auto Auto Control the
43. puters Manufacturers Group Ethernet is a registered trademark of Xerox Corporation IEEE is a registered trademark of the Institute of Electrical and Electronics Engineers Inc Intel is a trademark of Intel Corporation Pentium M and Celeron M are trademarks of Intel Corporation Microsoft is a trademark of the Microsoft corporation In addition his document may include names company logos and trademarks which are registered trademarks and therefore are property of their respective owners Fastwel welcomes suggestions remarks and proposals regarding the form and the content of this Manual CPC508 User Manual 3 2012 Fastwel Ver 001 E Fastwel Lee CPC508 Notation Conventions Warning ESD Sensitive Device This symbol draws your attention to the information related to electro static sensitivity of your product and its components To keep product safety and operability it is necessary to handle it with care and follow the ESD safety directions Warning This sign marks warnings about hot surfaces The surface of the heatsink and some components can get very hot during operation Take due care when handling avoid touching hot surfaces Caution Electric Shock This symbol warns about danger of electrical shock gt 60 V when touching products or parts of them Failure to observe the indicated precautions and directions may expose your life to danger and may lead to damage to your product Warning Information mark
44. routed to CPCI J2 connector PICMG 2 30 2 1 9 HD Audio CPC508 provides digital High Definition Audio interface routed via XS6 mezzanine connector to MIC589 module and firther to the backplane via CPCI J2 connector of MIC589 The interface includes line input output and microphone input channels 2 1 10 CompactFlash Socket Figure 2 6 CompactFlash Socket To enable usage of CF memory cards CPC508 has a CompactFlash Type I II socket located on the top side of the board CF removable mass storage devices are fully compatible with 16 bit ATA ATAPI 4 IDE interface with DMA support CF Specification v 4 1 CompactFlash socket is connected to the IDE port at the current version of CPC508 There is a bracket for fixing a CF card in the socket Table 2 1 CompactFlash Socket Pinout 1 GND Ground signal 2 D03 Data 3 In Out 3 D04 Data 4 In Out 4 DOS Data 5 In Out 5 DO6 Data 6 In Out 6 D07 Data 7 In Out 7 IDE_CSO Chip select 0 Out 8 GND 9 GND 10 GND 11 GND 12 GND 13 3 3 V 3 3 V power 14 A06 15 A05 16 A04 17 A03 18 A02 Address 2 Out 19 A01 Address 1 Out 20 A00 Address 0 Out 21 DOO Data 0 In Out 22 D01 Data 1 In Out 23 D02 Data 2 In Out 24 IOCS16 25 CD2 26 CDI 27 D11 Data 11 In Out 28 D12 Data 12 In Out 29 D13 Data 13 In Out 30 D14 D
45. t Panel 4HP Interfaces ccccceceeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeess 45 7 5 1 2 Interfaces Routed to CPCI J2 Connector eee eee eeeeceeeeee eee eeeeeeeeeeeeeeeeeeenneeeeeeeeenees 45 8 Supplementary Information 00 0 lili iiiiiiiiiiiiiiiinneneeeeneeeeeeeeeenees 46 8 1 Related Standards and Gpechficattomg eee eeeiit ttet tetkin ttt tatttk ttnn nattt ttnn tannttttnnnnnnnseeenn nnt 46 9 Useful Abbreviations Acronyms and Short Cuts ccsccceeeeeeeeec eee eeeeeecneeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeseeee 47 List of Tables Table 2 1 CompactPCI Connector Coding Colors cccceeecceeneeeeeee eee eecenieeeeeeeeeeeneneeeeeeeeeeeenieeeeeeeeeeee 14 Table 2 2 CompactPCI Bus Connector J1 XS8 System Slot Pinot 15 Table 2 3 32 bit CompactPCI Bus Connector J2 XS7 System Slot Pinot 16 Table 2 4 Pinout of XS6 Connector for MIC589 Mezzanine Module 17 Table 2 5 USB1 and USB2 Pinouts CPC508 Front Panel 18 Table 2 6 VGA XS1 Front Panel Connector Pinot 19 Table 2 7 Gigabit Ethernet Connectors Pinouts eee eeeceneeeeeeeeeeeencaeeeeeeeeeeenniaaeeeeeeeenees 20 Table 2 8 Land L2 LEDS le e 22 Table 6 1 DC Input Voltage Ranges and Limite 40 Table 9 1 Related RE El EE 46 Table 9 2 Related Specifications EE 46 CPC508 User Manual 2 2012 Fastwel Ver 001 E Fastwel Lee CPC508 List of Figures Figure 1 1 Figure 1 2 Figure 2 1 Figure 2 2 Figure
46. tion and Programming Fastwel Een CPC508 4 Configuration and Programming 4 1 WDT Operation TBA 4 2 L1 User LED Control TBA CPC508 User Manual 28 2012 Fastwel Ver 001 E Phoenix BIOS Setup Fastwel Ley CPC508 5 Phoenix BIOS Setup The Phoenix BIOS in your SBC is an adapted version of a standard BIOS for IBM PC AT compatible personal computers equipped with Intel x86 and compatible processors The BIOS provides low level support for the central processing memory and I O system units 5 1 Starting BIOS Setup With the help of BIOS Setup program you can modify the BIOS configuration parameters and control the special features of your module The Setup program is started by pressing the F2 key during POST procedure and offers a convenient menu interface to modify basic system configuration settings and switching between the subsystems operation modes These settings are stored in a dedicated battery backed memory CMOS RAM that keeps the information when the power is switched off For increased security the CMOS data and some of the service parameters are stored also in a nonvolatile FRAM memory This allows to restore the critical data in emergency cases after battery failure Figure 5 1 POST Screen Image Phoenix SecureCore tm Embedded Copyright 1985 2009 Phoenix Technologies Ltd All Rights Reserved JE FE HE FE HE HE FE HE JE HE JE FE JE AE AE JE JE JE JE EE EE JE JE EEE EE EE JE JE EE JE JE JE JE JE JE JE
47. uction Fastwel Een CPC508 a LPC bus Routed to mezzanine connector n Spec v1 0 compatibility Support for two Master DMA devices E PCI Express four x1 lanes Routed to CPCI J2 connector n Spec 1 1 compatibility Support for up to four x1 devices up to 2 5 Gbit s Flash BIOS SPI interface 16 Mbit 7 In system modification E NAND flash disk 4 GB NAND flash dual channel soldered 7 SATA interface 50 MB s read 45 MB s write Can be used as boot device E CompactFlash Type II socket Support for PIO amp UDMA modes UltraATA 100 66 33 E SATA interface n Up to 300 MB s n Two ports Routed to CPCI J2 connector E Gigabit Ethernet interfaces Two PCI E controllers 10 100 1000 Mbps Two RJ 45 frontpanel connectors Front rear switchable m USB 1 1 and 2 0 support Up to 8 devices two at CPC508 front panel two via MIC589 mezzanine connector four via CPCI J2 available at the backplane E FRAM Available via SMBus 64 Kbit 256 B RAM for BIOS Setup parameters storage E Real time clock 7 Integrated in ICH8M CR2032 battery backup 3V E Audio Discrete HD audio MN Routed to mezzanine connector a Watchdog timer e Fixed timeout period 1 6 s n Reset source m Hardware monitor Available via SMBus 7 Power voltages monitoring CPU and PCB temperatures monitoring a Front panel LED indicators 7 Disk drives activity LED g Programmable user LED CPC508 User Manual 9 2012 F
48. ule Moreover the module should not be placed on any surface or in any kind of package until the module and its heatsink have cooled down to ambient temperature Caution If your module does not allow hotswapping switch off the system power before installing the module in a free slot Disregarding this requirement could be harmful for your life or health and can damage the module or entire system ESD Sensitive Equipment This product comprises electrostatically sensitive components Please follow the ESD safety instructions to ensure module s operability and reliability gt gt E a Use grounding equipment if working at an anti static workbench Otherwise discharge yourself and the tools in use before touching the sensitive equipment a Try to avoid touching contacts leads and components Extra caution should be taken in cold and dry weather CPC508 User Manual 24 2012 Fastwel Ver 001 E Installation Fastwel Een CPC508 3 2 Installation Procedure To install CPC508 in a system follow the instructions below 1 Keep to the safety regulations of the Section 3 1 when performing the following operations Warning A Failure to accomplish the following instruction may damage the module or result in incorrect system operation 2 Ensure that the module configuration corresponds to the application requirements before installing For information regarding the configuration of the CPC508 refer to Chapter 4 F