Contents

1. BI O PAD M Biometric Keypad Reader User s Manual oso RD z Contents EDESCHPTTON WAN A R EEEE Raa E aE ai Ea TSAA A TSERE 3 2 SPECIFICATIONS rr ci 3 3 MOUNTING A j 4 WIRING ac eiii 5 5 CONNECTING BIOMETRIC READERS TO EWS CONTROLLER 5 5 1 CONNECTING BIOMETRIC READERS IN SAME RS485 LINE WITH THE EWS CONTROLLERS 00000 6 5 2 CONNECTING BIOMETRIC READERS WHEN ALL THE CONTROLLERS HAVE TCP IP COMMUNICATION 6 6 CONNECTING BIOMETRIC READERS TO 3RD PARTY CONTROLLER ee 7 6 1 CONVERTERS PIN DESCRIPTION a 7 7 ENROLLMENT ao g 8 CONFIGURING THE BIOMETRIC READERS IN PROS SOFTWARE ccc 8 8 1 ADDING BIOMETRIC READER sarria arar id tati g 8 2 ENROLLING FINGERPRINTS FROM A READER oras 9 8 3 ENROLLING FINGERPRINTS FROM DESKTOP READER 10 BA DELETING FINGERPRINTS sssqcsctencnetensanse parar trote ii eiii reia dat denies ada 11 8 5 UPLOADING THE FINGERPRINTS TO THE BIOMETRIC READERS vices socie dunas engrase dba tion diane cats db aca ia chide 12 O Da sonst aaa nasties yg II ZO WEZ puck ye EE OP P PA dA 12 SF INTRO geet e Seanad eaneen bene 13 AN es 13 S7Z2PNEELEGAPINICGJE ereen EER A aii aceon serena diod A 13 o O E E E eid pga Gbaaabenee rete 13 Seo CHAIN Ge PIN CODE PENG cree nr N eee A io 14 SOSENSOR CAEIBRATIOIN sei tc bd li pel a w a AA leal et ee ad add 15 SOS END CONF SURATION A eee 15 SILADYANCED DCETNNING rra AAA A A E A E E E ia O 15 9 CONFIGURING THE BIOMETRIC READERS IN BIOMANAG
2. Description for the 26 bits Wiegand format Each data block consists of a first parity bit P1 a fixed 8 bits header 16 bits of user code and a 2nd parity bit P2 Such a data block is shown bellow Parity bit bit1 8bitsheader 16bitsusercode 2 bytes Parity bit bit 26 P1 XXXXXXXX XXXXYYYY YYYYYYYY P2 Example 170 31527 1 10101010 0111101100100111 0 Note Parity bits are calculated as follows P1 even parity calculated over the bits 2 to 13 X P2 odd parity calculated over the bits 14 to 25 Y EAAJA AAJA AA B BB BB B B B BB B B B B BB O nA A _2 gi Parit Parit Site Code User Code Ra 11 SAFETY PRECAUTIONS J Do not install the device in a place subject to direct sun light without protective cover Do not install the device and cabling close to a source of strong electro magnetic fields like radio transmitting antenna Do not place the device near or above heating equipments lf cleaning do not spray or splash water or other cleaning liquids but wipe it out with smooth cloth or towel Do not let children touch the device without supervision Note that if the sensor is cleaned by detergent benzene or thinner the surface will be damaged and the fingerprint can t be entered 12 TROUBLESHOOTING J The Red Led on the Biometric Reader is blinking all the time There were 15 unsuccessful attempts of authentication F
3. 12 Note If more fingerprints are added for one user all fingerprints will send the same Wiegand Code to the controller the one written in the field User ID card Number Find user User ID s Card numbers 5339048 Access Code 1234 Name Sitecode 81 Usercode 30632 Ann Staplewood Wiegand 26 ID 5339048 Site code 81 Usercode 30632 Ari Peka Nicola David Smith Dino Radja Basic Personal details Personal details 2 mM Output control D Biometry Domnika Barda Elena Output control i Biometry Select reader to Enroll Send or Delete user Access level Unlimited Hans Enn Department General John Smith Workgroup sn M Josh Lee n M Controller2 a Main Entrance Valid from 1 28 2014 Mana Waliser Mateja Svet Valid until 12 31 2099 Michaela Figgini Apply Anti pass policy y Michaela Tabb PPY wic Setimage Nikola Cuculov Unset image Paul Hunter Single entry User Stole Toda Barda i Save changes Delete user s Properties Gb Check version gt Delete all users from reader 12 Upload all users to reader Delete pending updates a Delete expired users from reader 8 11 Reader Door Event 8 12 8 3 ENROLLING FINGERPRINTS FROM DESKTOP READER Plug the Desktop Reader BIOE in the PC If the device is not installed automatically use the drivers located on the CD provided with the Biometric reader It is installed in the same way as a USB Device When the desk
4. David Smith p vy a Z Personal ma Z Personal mM Output contra D Biometry Select reader to Enroll Send or Delete user Erica Hess Hans Enn je a a Deel John Smith Josh Lee z D peta 100 Mara Waliser Y W ys Elena Mateja Svet E test_new_3 9 Michaela Figgini a 02 140626004 Michaela Tabb g R2 140626004 Nikola Cuculov S 3 192 168 1 201 z EH Controller2 Single entry User Sz a a Main Entrance Toda Barda HB ful Main Entrance_E i E Door2 e gt Save changes 8 21 8 8 CHANGE PIN CODE LENGTH Go to Settings System parameters 8 24 Select the desired length and click Save amp Exit 8 25 Allthe readers in the network will automatically receive the change Note It is recommended to do this setting immediately after installing the software as this parameter will set the available number of PIN Code digits in the user form Example If the PIN code length is set to 6 digits then in the Users Window the PIN Code will require 6 digits entry 8 26 Biometry Find English Help Keycode length Wiegand w System parameters EY Web service Allow web reportfor users C Use default PC network interfac Controller s pulling cycle Start pulling of controllers and a 8 Automatic Evacuation report printing Scheduled tasks Eg Mail Settings B Automatic on Server startup Manual from program menu mata Serv
5. LED is OFF Fingerprint Sensor malfunction Check the Sensor position and its physical condition Reset the system Contact your installer Reader reading performance is decreased Check if fingerprint reading area is dirty Do not clean the device with any form of liquid Use soft and dry cloth only Reading area is damaged If the damage is minor try to calibrate the sensor Fingerprint is not recognized normally Retry after drying the wetness of your finger When your finger is too dry touch your forehead and try again When you have a cut on your registered finger register another fingerprint This product herewith complies with requirements of EMC directive 2014 30 EU In addition it complies with ROHS directive EN50581 2012 Visual Plus Corporation s a Dreve Richelle 161 WOP G Bte 34 O WF po 1410 Waterloo Belgium osa Access
6. calibration 9 5 ADD USER At user table click on the last empty user field and enter user name O Tam as TA El oo b Click on ID User code field and enter ID number This number will be sent by the reader to the access controller when user finger is recognized by the reader Click on PIN code field and enter the PIN PIN code is used at readers with keypad When PIN code is typed at reader User ID will be sent to the access controller 9 6 EDIT USER e Find the user at user table to edit e Click on the user field for edit Name ID or PIN e Type new value e Press Enter on the keyboard Important When ID is changed warning message is displayed reminding that if ID exist in some reader should be deleted from reader prior to change 9 7 DELETE USERS e Check the users to be deleted e Right click on the users table e Click on Delete checked users menu Confirm warning message Biomanager e Select the User in the User Column not the check box the check box is for sending the fingerprints and the User name cell will turn blue e Select the Biometric reader or Desktop reader BIOE from where the enrollment will be done Right click on the fingertip and select Enroll Swipe the finger on the Reader and the finger tip will become blue with percentage of successful enrollment given right beside the fingertip Note If more fingerprints are added for one user all fingerprints will send the same Wi
7. more fingerprints are added for one user all fingerprints will send the same Wiegand Code to the controller the one written in the field User D card Number Access Code 1234 Usercode 30632 Wiegand26 ID 5339048 Site code 81 Usercode 30632 Select reader to Enroll Send or Delete user rv Basic PA Personal details Personal details 2 Mm Output control D Biomety E a My P Access level Unlimited Department General Workgroup None Valid from 1 28 2014 Valid until 12 31 2099 Apply Anti pass policy v Set image i u R2 140626004 5 39 192 168 1 201 select read Enroll Delete all ntroller4 Calibrate 19 11 00 Memory tras 0 Delete all users from reader de Upload all users to reader 4 Delete pending updates 26 Delete expired users from reader 8 4 DELETING FINGERPRINTS In General the fingerprints are stored in the Biometric reader and in the Software Deleting can be done only in the readers or from both places Deleting one user from the biometric reader Select the User Click on Delete User The User together with its fingerprints will be deleted from both the software and the fingerprint readers 8 14 Deleting all users from the biometric reader Right click on the reader and select Delete all users from reader 8 15 Delete one or more fingerprints Select the User and open the Biometric tab Go to the fingertip that needs to be deleted right click and sele
8. on top of the event table Network portal Main entry No response If reader is online right click on reader and select Upload configuration fi Main entry Check at event table if configuration was successful Portal 28 03 2010 17 58 16 Network portal Main entry Configure Wiegand Succes 28 03 2010 17 58 15 Network portal Mam entry Configure Flexibility Level Succes 28 03 2010 17 58 15 Network portal Mam entry Save Flexibility Level Succes 28 03 2010 17 58 15 Network portal Main entry Configure parameters Succes 9 2 EDIT READER Right click on the reader and select Properties Edit reader properties and click Save button Right click on the reader and select Upload configuration DA pees eer y o ps f i f i Check at event table if configuration was successful n 28 03 2010 17 58 16 Network portal Main entry Configure Wiegand Succes 28 03 2010 17 58 15 Network portal Mam entry Configure Flexibility Level Succes 28 03 2010 17 58 15 Network portal Mam entry Save Flexibility Level Succes 28 03 2010 17 58 15 Network portal Main entry Configure parameters Succes 9 3 DELETE READER Right click on the reader and select Delete reader Main entry 9 4 CALIBRATE SENSOR Right click on the reader and select Calibrate See the events panel to check the calibration flow It is recommended to do sensor calibration once after reader is mounted Clean the fingerprint sensor before
9. or Delete Users from readers at right click menu As upload is progressing check boxes are cleared mining appropriate combination was successfully done When upload is over if there are still checked items repeat the upload command 9 12 CUSTOM WIEGAND BioManager has defined Wiegand 26 and 34 bit as standard options and other 3 Wiegand settings as user definable To setup custom Wiegand format Select Wiegand menu from Settings It Wiegand Custom 3 At Wiegand setup window select one from customs Wiegand Click on Save button Note Wiegand settings are out of scope for common end user Please ask your installer to set the parameters and do not change it later For more information please refer to BioManager User Manual 10 WIEGAND PROTOCOL DESCRIPTION The data is sent over the lines DATA O for the logic 0 and DATA 1 for the logic 1 Both lines use inverted logic meaning that a pulse low on DATA O indicates a 0 and a pulse low on DATA 1 indicates a 1 WWhen the lines are high no data is being sent Only 1 of the 2 lines DATA 0 DATA 1 can pulse at the same time Example data 0010 DO 5V OV 1 ms gt J 100 us D1 5V OV Data bit O approximately 100 us microseconds Data bit 1 approximately 100 us microseconds Time between two data bits approximately 1 ms millisecond Both data lines DO and D1 are high
10. CNV200 optional RS485 A all A RS485 B B i BIOMANAGER Software Ugg CNV300 PALA 0 A 0 00 e Connectthe lines DO D1 Gnd and 12V to the third party controller e Connect the RS485 Line A B to the converter Connect the converter in the PC e Fingerprint enrollment is done from the PC Software Connection between the Biometric readers and the PC must be established e The Biometric readers communicate with each other with a RS485 and with the PC Software through a Converter e The RS485 Line should be configured in the form of a daisy chain NOT ina form of a star Keep the stubs from the RS485 backbone as short as possible not more than 5 meters e Only one converter per installation is needed not per reader 6 1 CONVERTERS PIN DESCRIPTION PIN 1 PIN 1 a PIN 1 CNV100 CNV200 CNV300 Converter RS485 to RS232 Converter RS485 to USB Converter RS485 to TCP IP Does not requires installation Requires installation as USB serial Does not require installation IP device refer to CNV200 Manual The address set through Internet Drivers are located on the CD Browser refer to CNV300 Manual Biometric Reader Converter RS 485 A PIN 1 RS 485 RS 485 B PIN 2 RS 485 7 ENROLLMENT 8 CONFIGURING THE BIOMETRIC READERS IN PROS CS SOFTWARE 8 1 ADDING BIOMETRIC READER 1 Expand the Door item to view the readers 2 Right click on the reader and select properties 8 1 3 In
11. ER 16 9 1 ADD READER ames traido rara iaa AATE hs i tarda be hi 16 SJEDIT READE resi A AO POW A AAA PIO AO OJEW ise GE vee PER EO SPORA OWA PREY OPO pace 17 O 3 DELETE READER mission ODA AO OSO 18 9 4 CALIBRATE SENSOR cocca cc nnn bbb bb bbb rene 18 9 5 ADD USER sarita ida e ii ii oi ir iodo i n 18 SOCED OSER put a ciao 18 SS PDELELTEUSENO aia 19 SOENDOECNINGERS ereere iS OOO Adi a GOCHA OPO paros AAA adi corea o podas ips 19 9 9 UPLOAD FINGERPRINTS TO READER ooo anie dE O A A PO ear A EA AO rta cinto eto cds 19 9 10 DELETE FINGERPRINTS soo aka Z a ac pp JET Aa ARG R AO Zi tt atan iaa 20 9 10 1 Deleting one user from the biometric reader 20 9 10 2 Deleting all users from the biometric reader 20 oo Petal eS C1 Aad Bley a USER UPLOAD artritis eee eer ee ne ee eee ee a 20 eZ SO BUSIE U IPON ENEI 21 10 WIEGAND PROTOCOL DESCRIPTION co 22 11 SAFETY PRECAUTIONS A T 12 TROUBLESHOOTING E 23 1 DESCRIPTION BIOPAD M isa Wiegand biometric keypad for access control applications with backlit keys and programmable wiegand output It offers storage up to 9500 fingerprints programmable Wiegand Output 8 to 128 bits and selectable PIN Code length The tamper switch output can trigger the alarm system if an attempt is made to open or remove the unit from the wall 2 SPECIFICATIONS J Fingerprint capacity up to 9500 fingerprints Technology Biometry and Keypad Authentication Fingerprints per user Finger PI
12. N Code Finger or and PIN Code 1 10 fingerprints PIN Code Length 1 8 Digits Interface Wiegand 8 to 128 bits Default Wiegand 26bit Protocol programming By PROS software EWS system and BIOMANAGER all access control systems Cable distance 50m Fingerprint Sensor Type Capacitive 1 1000 identification time 970 msec including feature extraction time Fingerprint enrolment On the reader or from the USB desktop reader BIOE Panel Connection Cable 1m Green and Red LED Externally Controlled Orange LED Idle mode Buzzer Yes Backlight ON OFF Yes by software settings Tamper Yes Consumption Max 130mA IP Rating 65 Power supply 9 14V DC Operating Temperature 15 C to 60 C Dimensions mm 100 x 94 x 30 Housing Moulded Aluminium Colour Silver Red Green Dark Grey Blue White 3 MOUNTING J _ _ ATPD MINI 94 mm 30 mm If the biometric reader is installed and used outdoor the reader MUST be fitted with the MCD MINI polycarbonate cover available in our accessories in order to protect the sensor from direct rainfall The operating temperature of the product is between 152C 602C If the reader is installed in an environment where the temperature can drop below 102C or and if the sensor could only be exposed to di
13. Properties and go to the Biometric tab oe i Finger Acceptance Flexibility omatic Secure For Entry Mode select Access Code or Finger 8 20 NA 7 PIN Code or Finger Send this ID for unknown finger Go to the Biometric tab Put the serial number of the Biometric Backlight Reader For Entry Mode select Access Code or Finger Entry mode PIN Code and Finger Go to the Biometric tab Put the serial number of the Biometric gt Reader L Send this ID for button A For Entry Mode select Access Code and C Send this ID for button B Finger 8 20 8 7 2 Finger and PIN Code Right click on the biometric reader Select Properties and go to the Biometric tab For Entry Mode select Access Code and Finger 8 21 Finger Use of the double security mode Access Code or Finger Type the PIN Code ex 3434 in the next 8 sec the reader will blink in orange waiting for the finger Present the finger 8 7 3 Finger Only Right click on the biometric reader Select Properties and go to the Biometric tab For Entry Mode select Finger 8 22 Access Code or Finger Access Code AND Finger Note In this mode the keypad will become inactive 8 22 Find user User name Domnika Barda _ UserID s Card numbers 88009016 Access Code 3434 Name gt Site code 1342 User code 59704 Ann Staplewood Wiegand 26 ID 4122936 Site code 62 Usercode 59704 Ari Peka Nicola
14. al cable length termination cable type so recommendation is to keep stubs shorter than 5 meters keeping in mind that this can be possible reason for errors in Communication with PC software e The cable must be twisted and shielded with a min 0 2 mm2 cross section e Connect the ground OV of each unit in the RS 485 Line using a third wire inthe same cable e The shield of the communication cable between two devices must be connected to the EARTH from ONE side of the RS 485 Line Use the side that has earth connection to the building s grounding network 5 2 CONNECTING BIOMETRIC READERS WHEN ALL THE CONTROLLERS HAVE TCP IP COMMUNICATION mu z m 2 e UUE A UUE LA R Mae 0044316500 z EO Moe 00443 16500 El E A E LLL 11 gt Switch e When all the controllers are connected via TCP IP then the RS485 network becomes local from Reader 1 to the Controller then to the Reader 2 e Connect the readers directly to the Rs485 terminals in each controller e f the distance Reader Controller is high 50meters and if the communication with the reader can not be established then terminate the RS485 network by closing the jumper in the EWS Controller or as described in chapter 4 6 CONNECTING BIOMETRIC READERS TO THIRD PARTY CONTROLLERS 3rd party controller 3rd party controller DO D1 DO D1 DO D1 DO D1 CNV100 BIOE USB Desktop Reader m Hal
15. ally This function is used if the reader was off line while making the changes 8 11 ADVANCED SETTINGS Send This ID for Unknown Finger sends the desired Wiegand when an unknown finger is applied Unknown PIN sends the desired Wiegand when an unknown Pin Code is applied Button A Pressed sends the desired Wiegand when button A is pressed Button B Pressed sends the desired Wiegand when button B is pressed Click on the Save amp Exit button Sound level Sound level of the device ON or OFF Finger Acceptance Flexibility Accepted tolerance The recommended value is Automatic Secure Sensitivity Bio sensor sensitivity the recommended value is 7 most sensitive af Properties ge Check version dy Firmware update Get settings Send configuration Calibrate Memory status Delete all users from reader Upload all users to reader Delete pending updates Delete expired users from reader Properties Check wersion Firmware update Get settings Send configuration Calibrate Memory status Delete all users from reader Upload all users to reader Delete pending updates Delete expired users from reader Basic Free Access Time Zones Biometric Serial 13 05 10 005 Sound level 5 ll Finger Acceptance Flexibility Automatic Secure had Sensitivity 0 lowest i id Backlight 50 w Send this ID for unknown finger Entry mode Access Code or Finger C Se
16. are doubts that fingerprints in the reader memory are not synchronized with the software database In normal usage the fingerprints are sent automatically and this feature is not used z Properties Gb Check version 45 Firmware update Ag Get settings Send configuration roller Es Calibrate 09 110 Memory status 3 Delete all users from reader Upload all users to reader E Delete pending updates le amp Delete expired users from reader 8 17 8 6 FIRMWARE UPDATE Right click on the reader and select Firmware update menu 8 18 On the Firmware update window click on the Browse button 8 19 The default location of the firmware files installed with PROS CS is in the folder Firmware Select the firmware file with a xhc extension Click on the Upload button Important Wait for the update end message Do not turn off the reader the software or any communication device in between during the entire process l nur m m f i Mmware Update af Properties sd qe Check version Device Main Entrance_BIOC2 et Jutputs Af Get settings roller3 Send configuration Version pane Joor2 Firmware file roller4 Calibrate 9 11 000 Memory status gt Delete all users from reader GH m de Upload all users to reader Upload G Delete pending updates s Delete expired users from reader 8 18 8 19 8 7 ENTRY MODE 8 7 1 Finger or PIN Code Right click on the biometric reader Select
17. ct Delete for one finger or Delete All for all fingers of the User Click Save Changes With this procedure the User s fingerprints are deleted from the software and from the reader 8 16 Find user User name Erica Hess UserID s Card numbers 5339048 Access Code 10000 Propertie Name Site code 81 Usercode 30632 Ann Staplewood Wiegand 26 ID 5339048 Site code 81 Usercode 30632 Ari Peka Nicola David Smith Dino Radja Basic Z Personal details PA Personal details 2 ja Output control D Biomety Check wersion Firmware update Get settings Domnika Barda Elena ne O Hans Enn Department General send configuration Calibrate John Smith None Workgroup Memory status Mateja Svet Valid until 12 31 2099 Michaela Figgini Apply Anti pass policy y Michaela Tabb PPY PEM Setimage Single entry user Delete all users from reader Upload all users to reader Delete pending updates Nikola Cuculov Unset image Paul Hunter RE SMO Xaab oN Delete expired users from reader Single entry User Stole Toda Barda Enroll Delete all 8 16 8 5 UPLOADING THE FINGERPRINTS TO THE BIOMETRIC READERS Right click on the biometric reader Select Upload all users to reader While receiving the fingerprints the reader will blink in orange Note Use this feature when you change or add a reader if pending tasks are deleted in the software or if there
18. egand Code to the controller 9 9 UPLOAD FINGERPRINTS TO READER Check the users which fingerprints will be sent to the Reader Right click on the Biometric reader those users should be sent and select Upload users B Main entr As each user is being sent the checkbox will become unchecked indicating that the user is successfully sent In the same time the orange LED of the Biometric reader blinks Note Average time for transferring one finger template is 0 6 sec Note The PIN Codes are also being sent if there are any 9 10 DELETE FINGERPRINTS After the transfer the fingerprint are stored in the Biometric reader and in the PC Deleting can be done only in the software only in the readers or from the both places 9 10 1 Deleting one user from the biometric reader Select the users checkbox The user is deleted from the reader but his fingerprints are still in the software s database They can be sent ones again without the need of re enrollment 9 10 2 Deleting all users from the biometric reader Right click on the Reader and select Delete all 9 11 COMPLEX USER UPLOAD Complex user upload is used to sent multiply user selection to more readers Click on Upload table at main menu L Use mouse click to select the combination you need or use right click to check or clear entire row or column _8 8 8_ lmely B Tom Smith B tea ia La Select Upload Users to readers
19. ers 8 25 Export Client parameters Pending updates USB Dongle Registration Restart Server 8 24 Find user Username Domnika Barda RE RE owe User ID s Card numbers 88009016 Access Code 003434 ID Site code 1342 Usercode 59704 Wiegand26 ID 4122936 Site code 62 Usercode 59704 Name Ann Staplewood 3 E f i B Personal details Personal details 2 m Output control Biome Ari Peka Nicola 0 gt U Personal detais A Personal a D wy David Smith Dino Radja Access level Unlimited Department General Elena Workaro Workroup_Marketing Erica Hess z Hans Enn Valid from 1 28 2014 ma Valid until 12 31 2099 Josh Lee Maria Waliser Apply Anti pass policy Setimage Mateja Svet Single entry user Michaela Figgini Unsetimage Michaela Tabb Nikola Cuculov Paul Hunter Single entry User Stole New user i Delete user 8 26 8 9 SENSOR CALIBRATION Right click on the biometric reader and select Calibrate and wait for confirmation message Note It is recommended to do a calibration while commissioning the reader and in cases when there are problems with reading the fingers 8 10 SEND CONFIGURATION Right click on the reader and select the Send configuration menu See the events panel to check the configuration flow Note The biometric reader gets its settings automatic
20. h devices Jea DINMTPX M a Delete pending updates O k _ DINBIO DINMTPX MF E Firmware U pd ate Delete expired users from reader 8 2 8 2 ENROLLING FINGERPRINTS FROM A READER 1 Open the Users Window and create a new user Click on New User put a name ID card number and Access Code 8 7 Go to the Biometric Tab Select the reader with left click from which the enrollment will be done 8 8 Right click on the fingertip and select enroll 8 9 In the next 25 sec present the finger on the selected reader and the finger tip will turn red with the percentage of successful enrollment shown next to the fingertip 8 10 In these 25 sec the reader will continuously blink in orange Repeat point 4 amp 5 for each finger that should be enrolled 7 Click on Save New and the fingerprint will be sent automatically to all Biometric Readers where that user has access i e to all the readers according to the Access Level assign to that user um AUN OD Example If the user has Unlimited Access level then the fingerprints will be sent to all readers if the user has Access level only for Reader1 and Reader 3 then the fingerprints will be sent only to those two readers Note To check if all the fingerprints are sent to the reader right click on the reader and select Memory Status 8 11 In the event window a line will appear indicating the number of fingerprints stored in the reader 8
21. inger or PIN The Red LED will turn off after the first accepted finger or PIN The keypad of the Biometric Reader is not working The operation Mode of the Biometric Reader is set as Finger Please select Keycode OR Finger mode Enrollment from desktop reader can be done but the Fingerprints are not sent to all Biometric Readers in the network Check the Ser No of the Readers Check if proper termination is done as described before Check if the Communication wires A amp B are properly connected to the reader The Biometric Reader is not powered ON The tricolour LED is OFF Check the power Supply red amp black wire Fingerprint or PIN Code is recognized the tricolor LED is green but the controller reports other ID number and the access is denied If the user is not deleted from the reader and the same user is enrolled again with new ID the reader will recognize the finger with the first 1D To resolve this delete all users from the reader and upload all users to the reader Check the Wiegand Bus yellow amp white wire Check if the ground of the controller and the Biometric Reader is the same Check if the length between Biometric Reader and the controller is less than 50 m Electro static discharge influences the Fingerprint Scan Connect the housing of the Biometric Reader to the earth wire PIN Codes are working correctly finger scan does not work The triocolour
22. nd powered on the LED should flash in orange light 2 beeps This lets you know it s on and ready for use Fingerprint enrollment is done from the PC Software Connection between the Biometric readers and the PC must be established mL c40 i LD22 e _ ys eee EC R O 12Vdc Out z Y N 3 50 Ez PES gt m Max A X 2 bs e E z Z A Ser No 11 04 16 013 B Mac 00 04 A3 16 90 D E ZEE E Q fe S 5 2 ZZ 2 L a res nin nin e El A Hello gt e a 8 MAD o NN 2 z a E z lt gt Z lt 2 aa U o 2 lo e g o lo fe q gt w S i sd ZODROOOO OOOO screw A BE EP Do ET Do pink A violet B green LG orange LR black GND red 12V white DO yellow D1 5 1 CONNECTING BIOMETRIC READERS IN SAME RS485 LINE WITH THE EWS CONTROLLERS Jumper for Jumper for RS485 termination RS485 termination TCP IP e The Biometric readers are connected through RS485 bus The same RS485 bus that the EWS controllers are connected to e Maximum units in one network EWS Biometric readers is 32 e Ifthere are more than 32 units in one network please utilize RS 485 HUB to connect e The RS485 Line should be configured in the form of a daisy chain NOT in a form of a star If star must be used in some points keep the stubs from the RS485 backbone as short as possible Maximum length of the stub is dependant of the installation total number of devices in RS485 line tot
23. nd this ID for button A C Send this ID for button B Save amp Exit 9 CONFIGURING THE BIOMETRIC READERS IN BIOMANAGER BioManager is software for fingerprint management of XPR Biometric readers when used with third party access controllers Main functions Fingerprint Enrollment It can be done by ANY Biometric reader in the network or by Desktop USB Biometric reader Note The Desktop Biometric reader BIOE is only compatible to Biometric readers with capacitive sensor not with the ones with thermal sensor Fingerprint Transfer Finger templates can be sent to any Reader in the Network Different Users can be sent to different Biometric readers PIN Codes management and transfer PIN Code length configuration 1 to 8 digits and PIN Code transfer Wiegand Output Configuration The Wiegand output of the Biometric reader can be customized bitwise 9 1 ADD READER Fill the Reader form Right click on the portal connected to the reader and select Add reader Network portal w Wiegand26 Automatic More Secure Finger 0000000000 000000000 000000000 0000000000 Click on Save and the reader icon appears Right click on reader and select Version info under the selected portal u 5 Network portal If reader is online new line is added on top of the event table PORNOS Network portal Main entry Device online Type Bior Version 1 22 If reader is not online following line is added
24. rect sunlight it is strongly recommended to install the reader inside a third party sealed wall mount box fitted with additional heater if very low temperature to keep a constant sensor level performance XPR cannot guarantee the functionality of the product if measures and advice before are not followed Itis also strongly recommended to use double technology biometric readers when use outdoor to offer first higher security but also the possibility to use different readers depending on users 4 WIRING J Red ME 12VDC Black MM GND Pink ZII A Violet MIN B RS485 Orange EET LR LED Red Green MH LG LED Green White r DO Yellow HEEE Di WIEGAND Gray LS Tamper Blue MEN Tamper 12V DC GND round B a Soe DI Da a1 a 696 Data 1 Tamper Tamper Switch NO p Tamper Tamper Switch NO 5 CONNECTING BIOMETRIC READERS TO EWS CONTROLLER J The Biometric readers can be connected to virtually any controller that conforms to Wiegand format standards standard Wiegand 26bit or self defined Wiegand The lines DO and D1 are the Wiegand lines and the Wiegand Number is sent through them The RS485 line A B is used for fingerprint transfer and reader settings The Biometric readers must be powered from the controller If you use different power supply for the biometric reader connect the GND from the both devices to ensure correct transfer of the wiegand signal When you have connected the reader a
25. the Basic tab for Type of the Reader select BIOPAD M 8 2 4 After selecting the type a third tab will appear Biometric Go to that tab and put the serial number of the Biometric Reader 8 3 Important Note The serial number of the reader can be found on a sticker inside the reader on the packaging box and it can be search from the software right click on the portal search devices readers 8 4 amp 8 5 To check if the reader is On Line right click on the reader and select Check version In the Event Window a message should appear Device ON Line Type BIOPAD M 8 6 D Controllers 9 Readers Basic Free Access Time Zones Biometric Serial Type Version z Cot saint BIOC2 12 Serial 05 08 12 055 sl D 12 04 28 074 BIOCSW 17 Sound level 5 gt 13 05 10 005 BIOC 24 o z BIOC3 Finger Acceptance Flexibility Automatic Secure BIOPROX EM BIOPROX MF Sensitivity 0 lowest BIOPROX MF FOC i BIOPAD M C Send this ID for unknown finger 14 08 16 001 niNBIO 1 8 DINBIO DINMTPX M DINBIO DINMTPX MF E DINBIO DINMTPX MF FOC DINBIO DINPAD M BIOC BIOCZ BIOC3 XL Properties BIOCSW siera Firmware update BIOINPROXSW Get settings y Add Controller Send configuration BIOPROX EM ie Calibrate BIOPROX MF a Properties BIOPROX MF FOC Memory status w 4 Delete Portal EKOA ab BIOXRC Delete all users from reader BIOXRSW E Upload all users to reader e Searc
26. top reader has been installed it will automatically appear in the Software 8 13 1 Open the Users Window and create a new user Click on New User put a name ID card number and Access Code 8 7 2 Go to the Biometric Tab 3 Select the USB desktop Reader with left click 4 Place the finger on the BIOE right click on the fingertip and select enroll 8 9 5 The finger tip will turn red with the percentage of successful enrollment shown next to the fingertip 8 10 6 Repeat point 5 for each finger that should be enrolled 7 Click on Save New and the fingerprint will be sent automatically to all Biometric Readers where that user has access i e to all the readers according to the Access Level assign to that user If the reader is off line the fingers will be sent upon the connection is established between PROS CS server and the reader No need for additional enrollment or actions The fingerprints will be sent as soon as communication is established Example If the user has Unlimited Access level then the fingerprints will be sent to all readers if the user has Access level only for Reader1 and Reader 3 then the fingerprints will be sent only to those two readers Note To check if all the fingerprints are sent to the reader right click on the reader and select Memory Status 8 11 Inthe event window a line will appear indicating the number of fingerprints stored in the reader 8 12 Note If