Home
User Program Settings Configuration
Contents
1. e Upon entering Program Mode the current program will be Program 1 User Program Version e A tone will be heard while the Start Stop button is pressed Q Program Mode Operation e To select a Program Tap the Start Stop button until the desired Program number is indicated by the Power LED e To change the Setting for the currently selected program Press and Hold the Start Stop button for 3 seconds to increment to the Setting number indicated by the 7x Rx LED then release the button Repeat as necessary until the desired setting is obtained e Refer to Section E 4 for a listing of Programs e Configuration Settings can also be changed using a PC Refer to Section E 6 for more information E 3 Program Mode Operation Versions 0 82 0 86 Q Overview e The current Program number is indicated by the Power LED blinking red o The number of red blinks indicates the Program Number Note If the Power LED blinks amber refer to Section E 2 above e The current Program Setting number is indicated by the 7x Rx LED blinking green o The number of green blinks indicates the Program Setting e While traversing through the Program and Setting numbers the Setting will wrap around to the beginning after reaching the end Example LED s Power 2 red blinks Tx Rx 3 green blinks Means Program 2 Setting 3 Output Level set for MED HIGH Rosetta Lt User s Manual E 3 e Upon entering Prog
2. Appendix E Configuration Programming This section describes how to set the user programmable configuration settings The correct program settings are required to match the communications hook up for proper operation Note Configuration Programming is applicable only for units with firmware version 0 82 and later E 1 Program Mode To Enter Program Mode e Make sure the unit is NOT connected to the monitor defibrillator e Remove the battery compartment cover e Disconnect and remove the 9V battery carefully e Locate the two dip switches visible in one corner of the battery compartment E a E hF e Using a ball point pen or similar tool slide DIP switch 2 to the Off position towards the inside of the Rosetta Lt Ba E ER e Reconnect and install the 9V battery be careful not to stretch or pinch the wires e Reinstall the battery compartment cover Rosetta Lt User s Manual E 1 QO Determine Firmware Version Press the Start Stop button to turn the unit on in Program Mode If the Power LED o blinks red and then amber you have firmware version 0 88 or later Refer to Section E 2 for an overview of how Program Mode operates for these software versions o blinks red and then red again you have firmware version 0 82 0 86 Refer to Section E 3 for an overview of how Program Mode operates for these software versions o turns solid red you have firmware version 0 73 or prior and Confi
3. be used for normal operations e The MASTER may be used to repeat this process as necessary to clone additional units When done it can be taken out of Program Mode according to the settings in Section E 1 and can be used for normal operations Rosetta Lt User s Manual E 7 E 6 Changing Configuration Settings Using a PC Firmware versions 0 88 and later only Configuration Settings can be changed from a PC using EZ Set for Rosetta Lt Software Refer to the Changing Configurations Settings Using EZ Set Quick Guide located in the Support Center section of www general devices com Rosetta Lt User s Manual E 8
4. gnal Time Power LED blinks 6 times The Preamble Signal Time setting specifies the length of the tone that the Rosetta Lt sends out in order to wake up the receiver Setting Tx Rx LED blinks Setting 1 OFF 2 1 second 3 2 seconds factory default recommended 4 3 seconds Program 7 Auto Power Off scsscsseees Power LED blinks 7 times The Auto Power Off setting specifies the number of seconds that will elapse before the Rosetta Lt will turn off to extend battery life This is only applicable when operating on 9V battery power Setting Tx Rx LED blinks setting 1 20 seconds factory default recommended 2 60 seconds 3 120 seconds Rosetta Lt User s Manual E 5 Program 8 TX Un Key Off Time Power LED blinks 8 times The TX Un Key Off Time setting sets the number seconds the Rosetta releases it s PTT closure to un key the radio momentarily during transmission occurs just after 12L waveforms 45 sec This setting is desirable as a work around for use with radios that have a 1 minute talk out timer set Setting Tx Rx LED blinks setting 1 OFF 2 1 second 3 2 seconds factory default recommended 4 3 seconds Note The following programs vary with firmware version Refer to Program 1 to determine the version of your unit For Firmware Versions 0 82 0 85 Program 9 Clone Mode s csccsscssscseeees Power LED blinks 9 times The Clone Mode
5. guration Programming is not applicable to your unit Slide DIP switch 2 back to its original setting and refer to Appendix C Output Device Information Section C 4 for information on adjusting the output level setting To Exit Program Mode Ensure that you have configured all settings appropriately Remove the battery compartment cover Disconnect and remove the 9V battery carefully Locate the two dip switches visible in one corner of the battery compartment Using a ball point pen or similar tool slide DIP switch 2 to the On position towards the outside of the Rosetta Lt NI E aa Reconnect and install the 9V battery be careful not to stretch or pinch the wires Reinstall the battery compartment cover E 2 Program Mode Operation Versions 0 88 and later Q Overview The current Program number is indicated by the Power LED blinking amber o The number of amber blinks indicates the Program Number Note If the Power LED blinks red refer to Section E 3 below Rosetta Lt User s Manual E 2 e The current Program Setting number is indicated by the 7x Rx LED blinking green o The number of green blinks indicates the Program Setting e While traversing through the Program and Setting numbers the Setting will wrap around to the beginning after reaching the end Example LED s Power 2 amber blinks 7x Rx 3 green blinks Means Program 2 Setting 3 Output Level set for MED HIGH
6. ram Mode the current program will be Program 1 User Program Version e A tone will be heard while the Start Stop button is pressed QO Program Mode Operation e To select a Program Press and Hold the Start Stop button until the desired Program number is indicated by the Power LED then release the button e To change the Setting for the currently selected program Tap the Start Stop button to increment to the Setting number indicated by the Tx Rx LED Repeat as necessary until the desired setting is obtained e Refer to Section E 4 for a listing of Programs E 4 Configuration Setting Programs Program 1 Firmware Version 00 Power LED blinks 1 time Program 1 will output the current firmware version number The version consists of one digit Major number and two Minor numbers in the format of X YZ Note Program is for information purposes only and cannot be changed The unit beeps a low digit tone and then outputs X The unit beeps a high digit tone and then outputs Y The unit beeps a low digit tone and then outputs Z Setting Tx Rx LED blinks Setting 0 Version number is zero 1 9 Version number is 1 9 respectively Program 2 Output Signal Level Power LED blinks 2 times The Output Signal Level setting specifies the Output Level of the Rosetta Lt as described in Appendix C Setting Tx Rx LED blinks setting 1 LOW used only is rare instances 2 MED facto
7. ry default recommended for most systems 3 MED HIGH use if MED is too low 4 HIGH used only is rare instances Program 3 Transmission Mode 0 Power LED blinks 3 times The Transmission Mode setting sets the Rosetta Lt Transmission Mode This should be left as default Ox unless instructed otherwise by General Devices technical support as this setting must match the receiving equipments capabilities Rosetta Lt User s Manual E 4 Setting Tx Rx LED blinks setting 1 Mode 0x DTMF lead ID factory default recommended if DTMFs pass 2 Mode 1x FM lead ID use if DTMFs do not pass reliably 3 Mode 2x Special FSK not compatible with all Rosetta Rx CAREpoint receiving equipment Program 4 Auto Transmission 0 Power LED blinks 4 times The Auto Transmission setting configures the Rosetta Lt to begin transmitting after a manual button press recommended setting or automatically once a 12 Lead has been stored Setting Tx Rx LED blinks setting 1 Off factory default recommended 2 On only to used when the unit is always connected to the radio Program 5 Serial Baud Rate ss000 Power LED blinks 5 times The Serial Baud Rate configures the baud rate speed of the Rosetta Lt This setting must match the baud rate of the Monitor Defib or PC Setting Tx Rx LED blinks setting 1 38400 bps factory default recommended 2 115200 bps L Program 6 Preamble Si
8. setting will put the Rosetta Lt into Clone Mode For more information of Clone Mode refer to section E 5 Setting Tx Rx LED color indicates setting RED Master or Slave Unit when initially connected to master AMBER Cloning GREEN Slave Unit Cloned For Firmware Versions 0 86 and later Program 9 Text Data Mode sscceeees Power LED blinks 9 times The Text Data Mode setting selects what interpretation text data is sent after the ECG waveforms Setting Tx Rx LED blinks setting 1 No Text Data fastest transmission use if text data is not received reliably 2 Age Sex Data only sends only age amp sex data 3 All Text Data sent factory default recommended if received reliably Program 10 Clone Mode scscsscsscseees Power LED blinks 10 times The Clone Mode setting will put the Rosetta Lt into Clone Mode For more information of Clone Mode refer to Section E 5 Setting Tx Rx LED color indicates setting RED Master or Slave Unit when initially connected to master AMBER Cloning GREEN Slave Unit Cloned Rosetta Lt User s Manual E 6 E 5 Clone Mode Clone Mode allows the user to configure one Rosetta Lt device and then quickly transfer these settings to other units This process requires a special Cloning Cable 034 183 019A that can be obtained from General Devices Notes The Rosetta units used in cloning must be of the same firmware version Contact General Devices for informa
9. tion on updating Rosetta firmware in the field The MASTER unit will be on for several minutes when in Clone mode Battery life may be reduced if several units are to be cloned Start with a new battery and replace as necessary To Use Clone Mode e The unit that has the desired settings is referred to as the MASTER e The unit that you would like to add these settings to is referred to as the SLAVE e Both units must be in Program Mode according to the settings in Section E 1 e Put the MASTER into Clone Mode as specified by the Configuration Setting Programs above The Power LED will be blinking amber and the Tx Rx LED will be solid red Power LED will be blinking red for versions 0 82 0 86 e Connect the MASTER to the SLAVE using the Clone Cable 034 183 019A e The SLAVE will wake up and have a solid Red Power LED e Soon both the MASTER and SLAVE will have a solid Amber Tx Rx LED This indicates that the cloning process is taking place This is a very short process and usually only takes a few seconds e Finally both the MASTER and SLAVE will have a blinking amber Power LED and a solid Green Tx Rx LED Power LED will be blinking red for versions 0 82 0 86 e Disconnect the Clone Cable from the MASTER and the SLAVE e The SLAVE unit can be taken out of Program Mode according to the settings in Section E 1 It may now
Download Pdf Manuals
Related Search
Related Contents
User Manual Honda B16/B18 Supercharger kit version 1.0 HQ P.SUP.CAR10- Petite bibliographie d`articles de presse relatifs au manga 1 - Sony Hubbell UE32 User's Manual Gainward 4260183361381 NVIDIA GeForce GT 220 graphics card Samsung GT-S3370E Vartotojo vadovas Manuel d`installation de soffites Ideal Pet PDSM Installation Guide Copyright © All rights reserved.