1. when touching the housing parts and the heating plate The heating plate can reach temperatures of 340 C e Pay attention to the residual heat after switching off Protective ground contact e Make sure that socket is earthed protective ground contact before use e When work wear the personal guard to avoid the risk from Splashing and evaporation of liquids Release of toxic or combustible gases e Set up the instrument in a spacious area on an stable clean non slip dry and fireproof surface do not operate the instrument in explosive atmospheres with hazardous MS H S Analog Hotplate Magnetic Stirrer substances or under water e Gradually increase the speed reduce the speed if The stirring bar breakaway because of too high speed The instrument is not running smoothly or if the container moves on the base plate e Temperature must always be set to at least 25 C lower than the fire point of the media used e Beware of hazards due to Flammable materials or media with a low boiling temperature Overfilling of media Unsafe container e Process pathogenic materials only in closed vessels e If the case of the stirrer bar is PTFE please note Elemental fluorine three fluoride and alkali metals will corrode the PTFE and Halogen alkanes make it expansion at room temperature Molten alkali alkaline earth metals or their solution as well as the powder in second and third ethnic of the periodi
2. MS H S Analog Hotplate Magnetic Stirrer Cat No 12300135 User Manual MS H S Analog Hotplate Magnetic Stirrer MS S Analog Magnetic Stirrer Please read the User Manual and the related Video of this instrument on our website carefully before use and follow all operating and safety instructions The website www scilogex com SCILOGEX Contents AT a cotton eg serene esti teers 1 oK TTTRTTTRTTFFTTRTTTTTPTTT y 2 p 7 y qE y r 5 JF 2 WarTanty ss mmmusutsssi usunio suuo semus 2 1 Safety Iistriiellongss sss ana as 3 2 Proper USC se sss sisi susio ansan askuna can amo 4 E PRRERE L 4 3 1 Receiving Inspection oOorrmp E 4 32 Listing of MEM xu nepr sna Sage 4 A rial iii sss can Sr a nna 5 5 Control and Display 6 Operation T Uk J 6 8 Maintenance and Cleaning escsecienssiressesisnienss 6 9 Associated Standards and Regulations 7 10 Technical data ie riS TE 7 11 Products and Accessorles e eee eeestis 8 MS H S Analog Hotplate Magnetic Stirrer Preface Welcome to the MS H S Analog Hotplate Magnetic Stirrer User Manual Users should read this Manual carefully follow the instructions and procedures and beware of all the cautions when using this instrument Service When help needed you can always contact the sevice departm
3. c table of elements will have chemical reaction with PTFE when temperature reaches 300 400 C e The voltage stated on the label must correspond to the main power supply e Ensure that the mains power supply cable does not touch the hotplate Do not cover the instrument MS H S Analog Hotplate Magnetic Stirrer e The instrument may only be opened by experts 2 Proper use e Keep away from high magnetic field e Observe the minimum distances between the devices between the instruments and the wall and above the The instrument is designed for schools laboratories or factories This device is not suitable for use in residential areas or other areas that may cause danger to the user or instrument as mentioned in Chapter 1 assembly min 100 mm 3 Inspection 3 1 Receiving Inspection Unpack the equipment carefully and check for any damages which may have arisen during transport If it happens please contact manufacturer Limited for technical support Note If there is any apparent damage to the system please do not plug it into the power line 3 2 Listing of Items The packing includes the following items Items Qty Figure 1 Main unit 1 Power cable 1 Stirrer bar 1 User manual 1 Table 1 4 Trial run e Make sure the required operating voltage and power supply voltage match e Ensure the socket must be earthed e Ensure the power be off and the speed control knob and the temperature control knob to the
4. el Stirring bars 10mm x 6mm Ipes pk Stirring bars 15mm x 8mm Ipes pk E Stirring bars 20mm x 8mm l1pes pk 25mm x 8mm Stirring bars lpces pk 12500005 12500005 18900011 12500004 18900013 18900014 18900015 18900018 18900019 Stirring bars 30mm x 6mm Ipcs pk Stirring bars 30mm x 6mm Ipcs pk Stirring bars 50mm x 8mm lpes pk Stirring bars 40mm x 8mm l1pes pk 65mm x 8mm Stirring bars 1pes pk Stirring bars 80mm x 13mm Ipes pk Stirring bar mover Ipc F100 unit cover for none heat plate model MS Pro MS S F101 unit cover for heat plate model MS H S MS H Pro Table 5 SCILOGEX LLC 500 Four Rod Road Suite 122 Berlin CT 06037 USA Tel 1 860 828 5614 Fax 1 860 828 5389 E mail info scilogex com Website Http www scilogex com
5. elative humidity Protection class acc to DIN 60529 80 External rotor brushless motor 18 10 0 1500 1 Stainless steel porcelain enamel 135 500 MS H S 6 MS H S RT 340 MS H S 350 MS H S 280 x 160 x 85 2 8 5 40 80 IP42 Table 4 11 Products and Accessories Cat NO Descriptions 1121019959 esan Cag 220050 111210299 enmet USA plug OVS 811121039999 lareko Ska Steel 811121049999 s ne Ntug Steel 51112105999 enamel Baro plue 2002 811121069999 sone aan tt 81121108999 amro plug povis o 811121119999 T Steel 811121159099 MS H S with Heating Porcelain enamel USA plug 220V 50Hz 61Hz MS H S Analog Hotplate Magnetic Stirrer 811111019999 811111029999 811111039999 811111049999 Accessories 18900001 18900002 18900003 18900004 18900005 18900048 18900049 18900006 18900007 18900008 18900009 MS S without Heating Stainless Seel Cn plug 110V 220V 50Hz 60Hz MS S without Heating Stainless Seel Euro plug 110V 220V 50Hz 60Hz MS S without Heating Stainless Seel UK plug 110V 220V 50Hz 60Hz MS S without Heating Stainless Seel USA plug 110V 220V 50Hz 60Hz MS 135 1 Carrier plate Used with MS135 2 5 MS 135 2 Quarter 4 ml reaction vessel MS 135 3 Quarter 20 ml reaction vessel MS 135 4 Quarter 30 ml reaction vessel MS 135 5 Quarter 40 ml reaction vessel MS 135 6 Quarter 8 ml reaction vessel MS 135 7 Quarter 16 ml reaction vess
6. ent of manufacturer for technical support in the following ways SCILOGEX LLC 500 Four Rod Road Suite 122 Berlin CT 06037 USA Tel 1 860 828 5614 Fax 1 860 828 5389 E mail info scilogex com Website Http www scilogex com Please provide the customer care representative with the following information Serial Number on the rear panel e Description of problem i e hardware or software e Methods and procedures adopted to resolve the problems e Your contact information Warranty You have purchased a Scilogex instrument This instrument is warranted to be free from defects in materials and workmanship under normal use and service for a period of 24 months from the date of invoice The warranty is extended only to the original purchaser It shall not apply to any product or parts which have been damaged on account of improper installation improper connections misuse accident or abnormal conditions of operation For claims under the warranty please contact your local dealer You may also send the instrument direct to our works enclosing the invoice copy and by giving reasons for the claim You would be solely liable for freight costs 1 Safety Instructions Warning e Read the operating instructions carefully before use the instrument e Ensure that only trained staff work with the instrument e Forbid to heat the substances with low burning point or easy volatile MS H S Risk of burn e Caution
7. lowest position e Plug in the power cable and power on the device e Add the medium into the vessel with a stirring bar e Put the vessel on the plate e Set the rated stirring speed and the device begins to work e Set the rated temperature and the device begins to work MS H S e Keep the temperature control knob and the speed control knob slowly to the lowest position to turn off the function If these operations above are normal the device is ready to operate If these operations are not normal the device may be damaged during transportation please contact DragonLab corporation for technical support MS H S Analog Hotplate Magnetic Stirrer 5 Control and Display Heating Knob MS H S Stirring Knob Figure 2 Power Switch Figure 3 MS H S Analog Hotplate Magnetic Stirrer Items Descriptions Set the rated rotary speed in the safe i stirring range from 0 to 1500 rpm The airig function Stirring is switched ON or OFF via the knob Heat knob Set the rated temperature in the safe MS H S temperature range from room temperature to 340 C The function heating is switched ON or OFF via the knob LED heating Lit when heating ice i i N th LED Power When the device is switched ON the LED power is lit Switch ON or OFF Table 2 Mains switch 6 Operation e Put the device on the stable and safe place ensure the speed control knob and the temperature control knob to the lowest
8. position and plug in the mains power e Turn ON the power switch e Turn the speed control knob regulation to set the rated rotary speed in the safe speed limit from 0 to 1500 rpm e Turn the temperature control knob regulation to set the rated temperature in the safe limit from 0 to 340 C MS H S e The instrument begins to work Note Forbid to transfer the vessel when the instrument working or you must restart Stir function again avoiding Stirring bar breakaway 7 Faults e Ifa unit fault happens please power down the instrument e Switch OFF the unit at the main ON OFF switch for a few seconds e The stirring function will continue to operate at the speed set before the fault took place e The heating function will continue to operate at the set point before the fault took place e If the problem is not solved take the unit to your technical service center 8 Maintenance and Cleaning e Proper maintenance can keep instruments working in a good state and lengthen its lifetime e Be careful not spray the cleanser into the instrument when cleaning e Unplug the power line when cleaning e Only use cleanser that we advised as below Dyes Isopropyl alcohol Water containing tenside Construction materials 8 isopropyl alcohol Water containing tenside Cosmetics isopropyl alcohol Foodstuffs Water containing tenside Fuels Water containing tenside Table 3 e Before using other method for cleaning o
9. r decontamination the user must ascertain with the manufacturer that this method does not harm or destroy the instrument e Wear the proper protective gloves during cleaning of the instrument e The instrument must be cleaned and put it into the initial packaging carton before sending to service for repair avoiding the contamination of hazardous e Use the instrument in a dry clean room and temperature stable environment MS H S Analog Hotplate Magnetic Stirrer 9 Associated standards and regulations Construction in accordance with the following safety standards EN 61010 1 UL 3101 1 CAN CSA C22 2 1010 1 EN 61010 2 10 Construction in accordance with the following EMC standards EN 61326 1 Associated EU guidelines EMC guidelines 89 336 EWG Machine guidelines 73 023 EWG 10 Technical data Items Parameters Voltage VAC 200 240 100 120 Frequency Hz 50 60 Power W 530 MS H S 130 MS S Stirring point position 1 quantity Max stirring quantity H20 L 20 MS H S Analog Hotplate Magnetic Stirrer Max magnetic bar mm Motor type Max power input of motor W Max power output of motor W Speed range rpm Speed display accuracy rpm Hotplate material of the hotplate mm Heating power W Heating rate 1L water K min Temperature range C The safety temperature range of the hotplate C Dimensions mm Weight kg Permitted ambient temperature C Permitted r