Home

Placement in a System

image

Contents

1. 223 6 1 16 96 111 14 1 16 224 239 7 1 16 112 127 15 1 16 240 255 16 1041310B March 2003 KTD 460 463 User Manual KTD 463 Programming Use the following steps to program the contacts Note Unless otherwise noted in the following menus when a selection has been made press to advance to the next menu or press to return to the previous menu 1 Select CONTACTS on the main programming menu and press The following menu appears CONTACT 000 MOD 00 01 1 lt PREV NEXT The default contact number is 000 The module number and pin connection of the contact are also displayed Use and to scroll to the number of the first alarm contact you wish program CONTACT 000 MOD 00 01 SHUNT NO 1 lt NEXT gt 2 Each contact can be programmed to be shunted ignored Use and to enable or disable this feature CONTACT 000 MOD 00 01 SITE 000 14 lt NEXT gt 3 Use and to scroll to the camera site number with which the alarm contact will be associated CONTACT 000 MOD 00 01 SENSE 1 1041310B March 2003 17 KTD 463 Programming KTD 460 463 User Manual 4 The alarm contacts will be configured as normally open NO or 5 6 normally closed NC This affects how the KTD 463 reports a trouble state on an alarm input line see Step 6 in section 3 3 Setup Menus Use and to select whether the KTD 463 senses
2. dash normal okay state A alarm contact open if normally closed contact closed if normally open T trouble contact not reporting In the above example we see that contact number 2 the third contact on module 0 is in an alarm state Contact number 6 the seventh contact is in a trouble state This indicates either the contact has lost power through tampering or power outage or that it is not properly installed 4 1 SHUNTED CONTACTS If a contact was shunted during contact programming the A T and dash displayed on the Normal Operating Display will be replaced with a lowercase s The s changes depending on the state of the contact S shunted S shunted contact closed regardless of contact sense S shunted contact open regardless of contact sense 24 1041310B March 2003 KTD 460 463 User Manual Operation 4 2 PRINTED REPORTS If the printer is enabled see section 3 2 Printer Setup a hard copy of KTD 460 module and alarm contact activity will be printed See Figure 14 Date Time Site Contact Status Input Activity 09 24 99 11 05 32 SITE 128 CONTACT 128 CLSD MOD 08 01 ALARM ON 09 24 99 11 05 37 SITE 128 CONTACT 128 SUPR MOD 08 01 ALARM OFF 09 24 99 11 05 43 SITE 128 CONTACT 128 OPEN MOD 08 01 TROUBLE ON 09 24 99 11 05 57 SITE 128 CONTACT 128 SUPR MOD 08 01 TROUBLE OF 09 24 99 11 06 05 MODULE 08 TROUBLE ON 09 24 99 11 06 12 MODULE 08 TROUBLE OFF 0
3. Locate the removable terminal strips on the rear of the KTD 463 2 Make cable connections as shown in Figures 3 through 5 Observe polarity when connecting the Digiplex RS422 control cable e Observe polarity when connecting the RS485 alarm input cables 3 Supply power to the unit using the provided 9 VAC transformer 6 1041310B March 2003 KTD 460 463 User Manual KTD 463 Introduction Fuse RJ45 6 pin 16 pin terminal strips RS232 terminal strip Figure 3 KTD 463 back panel connections RS422 control __ RS422 control signal input signal output Figure 4 KTD 463 six pin terminal strip connections 1041310B March 2003 7 KTD 463 Introduction KTD 460 463 User Manual RS485 signal input up to 16 KTD 480s can be installed on one line or in any combination on separate lines Figure 5 KTD 463 16 pin terminal strip connections 1 4 CONNECTING THE PRINTER OPTIONAL A serial printer can be connected to the system using the RJ45 eight pin modular jack located on the rear of the unit See Figure 6 D RS485 ALARM INPUT PORTS 6 E 9 9 N 2 3 ue Figure 6 KTD 463 printer cable pinout connections RS232 Refer to section 3 KTD 463 Programming for initial setup and programming of the KTD 463 Note The KTD 463 cannot be programmed for proper operation until the KTD 460 alarm input modules have been installed 8 1041310B M
4. configuration is required see Figure 1 Note External devices are required for site annunciation functions Contact the factory for details CONTACT 000 MOD 00 01 PRESET NONE 1 NEXT 5 With this setting if the controller keypad and PTZ receivers have been programmed for preset positioning the camera will move to an assigned position when an alarm occurs In addition if preset tours have been assigned this setting can be used to activate the tours Example Alarm contact 2 is assigned to tour 2 on camera 1 When alarm contact 2 is activated camera 1 will begin its preprogrammed tour 2 If presets are being used determine the number of the preset position programmed into the site s PTZ receiver Use and to enter the same preset number If tours are being used maximum of four use and to assign a contact to a tour number CONTACT 000 MOD 00 01 MACRO NUM NONE 1 NEXT gt This setting is used to assign a programmed macro to an alarm contact Macro programming is done during setup Currently macros are reserved for custom Digiplex commands provided by the factory Exit to the main programming menu and repeat steps 1 through 9 for the next alarm contact 1041310B March 2003 19 KTD 463 Programming KTD 460 463 User Manual 3 2 PRINTER SETUP The KTD 463 features an RS232 serial port eight pin RJ45 jack which can connect to a printer or another serial device This enables the use
5. 4 1234 6 14 7 one 15 1234 1234 1041310B March 2003 13 KTD 460 Introduction KTD 460 463 User Manual Contacts 0 15 Contacts 128 143 Contacts 80 95 KTD 460 2 P i dE KTD 463 Figure 12 Example of module addresses not in sequential order Note Do not assign the same address to more than one module Programming failure will occur DIP switch positions 9 and10 are used for signal termination If the KTD 460 is the last module or only module on the RS485 control line terminate the signal If the KTD 460 is daisy chained to other units signal loop through do not terminate the signal e To terminate the RS485 signal set DIP switches 9 and 10 to ON e For signal loop through set DIP switches 9 and 10 to OFF 2 6 SuPPLYING POWER Supply power to the unit using the provided 9 VAC transformer The two LEDs on the side of the module blink to indicate the unit is transmitting and or receiving data See Figure 13 Transmit LED Receive LED Sem p mamme Transmit Short regular pulse Operating normally Receive Only one unit on RS485 line Short or long More than one unit on RS485 line regular pulse pulse gets longer with more units Figure 13 KTD 460 power LEDs 14 1041310B March 2003 KTD 460 463 User Manual KTD 463 Programming 3 KTD 463 PROGRAMMING Note The KTD 463 cannot be programmed for prop
6. 9 24 99 11 06 23 SITE 129 INF ALARM CLEAR 09 24 99 11 06 28 SITE 131 CONTACT 131 CLSD MOD 08 04 ALARM ON Figure 14 Example of printed activity report Notes on printed reports e Module trouble indicates the associated KTD 460 became disconnected or disabled e Infinite alarms can be cleared only by an external controller keypad e Under status CLSD closed SUPR supervised 1041310B March 2003 25
7. User Manual KTD 460 463 Alarm Input Module and Alarm Chassis GE Interlogix Kalatel 2003 Kalatel a GE Interlogix company All Rights Reserved Any GE Interlogix Kalatel division software supplied with GE Interlogix Kalatel division products is proprietary and furnished under license and can be used or copied only in accordance with the terms of such license This document contains proprietary information that is protected by copyright No part of this document may be reproduced or transmitted in any form or by any means without the prior written permission of GE Interlogix Kalatel division The information contained in this document is subject to change without notice GE Interlogix Kalatel division in keeping pace with technological advances is a company of product innovation Therefore it is difficult to ensure that all information provided is entirely accurate and up to date GE Interlogix Kalatel division accepts no responsibility for inaccuracies or omissions and specifically disclaims any liabilities losses or risks personal or otherwise incurred as a consequence directly or indirectly of the use or application of any of the contents of this document For the latest product specifications visit GE Interlogix Kalatel division online at www GE Interlogix com or contact your Kalatel sales representative For technical support before and after installation call 800 469 1676 Technical supp
8. arch 2003 KTD 460 463 User Manual KTD 460 Introduction 2 KTD 460 INTRODUCTION The KTD 460 alarm input module provides 16 alarm inputs supervised non supervised dry contacts or voltage sources Each supervised contact input communicates a status level of normal contact not activated alarm contact activated or trouble short or break on the alarm input line to the KTD 463 The KTD 460 also has an output relay that is energized when any alarm contact is closed 2 1 PLACEMENT IN A SYSTEM Up to 16 KTD 460 alarm input modules can be connected to the KTD 463 via RS485 twisted pair cable All 16 modules can be daisy chained on one line or can be connected in any combination on multiple lines up to 16 individual KTD 460s on 16 separate lines See Figure 7 IL jf lt AAA LH II 4 PITA 1 II I 1 40 1 4 LAIA PATA E um Figure 7 Examples of KTD 460 to KTD 463 connections Note If more than one KTD 460 is connected to the KTD 463 on the same alarm input port it must be connected in a daisy chain loop through configuration on a single line It cannot be connected in a parallel configuration 1041310B March 2003 9 KTD 460 Introduction KTD 460 463 User Manual 2 2 INSTALLATION CAUTION Com
9. ation Use the following steps Note Unless otherwise noted in the following menus once a selection has been made press to advance to the next menu or press to return to the previous menu 1 Select SETUP on the main programming menu and press The following menu appears CLEAR MEMORY YES NEXT gt 2 The CLEAR MEMORY option will erase all data in the alarm chassis nonvolatile memory and reload factory default values To clear the chassis memory press f The following menu appears ARE YOU SURE lt YES 3 This menu offers a safety check Press to reload the chassis memory with factory default values The screen will return to the master slave menu Press for no change FIND MODULES YES NO NEXT 1041310B March 2003 21 KTD 463 Programming KTD 460 463 User Manual 4 When the KTD 460s have been installed the KTD 463 must find and enable each module Press to initiate an automatic search for each module The following menu appears momentarily ALL ACTIVE MODULES WILL BE ENABLED When a module is found it is automatically enabled MODULE 00 ENABLED PORT 04 STOP NEXT 5 Press to stop the scrolling and hold on the module displayed Pressing advances to the report trouble menu When the status of all modules has been reported the display automatically advances to the next menu Note On new installations or if new alarm
10. e 11 Supervised contact configurations resistor 8 2K Note A supervised contact indicates that the alarm contact line contains a resistor Unsupervised contacts no resistors can be installed on the KTD 460 in which case the REPORT TROUBLE feature must be disabled see section 3 3 Setup Menus 12 1041310B March 2003 KTD 460 463 User Manual KTD 460 Introduction 2 5 SETTING THE DIP SWITCH Locate the 10 position DIP switch on the KTD 460 Figure 8 and set as follows DIP switch positions 1 through 4 are used Table 1 DIP switch settings for module addresses to set the module DIP switch Module DIP switch Module address Each setting Address setting Address module will have an mi address range from T 0 I 8 0 to 15 See Table 1 0N O0N Note DIP switch positions u 1 T m 9 E NN on 5 through 8 are not 1234 1234 programmed for use 0N 0N Note The module au EN 2 EN 10 addresses do not need to 1234 1234 be set in sequential order nor in the order in which nm a EE they are installed For on 3 11 example modules 0 8 EE 1 2 5 0N oN chained on the same 4 al 12 EE on RS485 alarm input cable 1234 1234 See Figure 12 n 5 13 123
11. er operation until the KTD 460 alarm input modules have been installed For new installations follow the programming instructions in the order in which they are given To update programming enter the programming mode and advance to the appropriate screen All programming menus will be displayed on the KTD 463 s LCD screen The first time power is supplied to the unit the following menu appears NO MODULES ENABLED ENTER PROGRAM MODE This menu will not be displayed again after programming data is entered unless the CLEAR MEMORY option is selected in section 3 3 Setup Menus 1 Toenter the programming mode simultaneously press and hold the and keys for 3 seconds The following prompt appears ENTER ACCESS CODE 2 Enter the security code by sequentially pressing gt 4 The following screen appears CONFIG MASTER NO SLAVE 1 EXIT NEXT 3 A second KTD 463 can be configured as a slave chassis providing an additional 256 alarm contact inputs The slave chassis must be located ahead of the master on the RS422 control line Use the and keys to scroll through the choices MASTER NO SLAVE MASTER w SLAVE and SLAVE For systems with one KTD 463 less than 256 alarm contact inputs select MASTER NO SLAVE 1041310B March 2003 15 KTD 463 Programming KTD 460 463 User Manual Note All contacts on the slave unit are programmed from the master chassis How
12. ever finding and enabling KTD 460 modules connected to the slave is performed from the slave chassis see section 3 3 Setup Menus ENTER CHOICE CONTACTS 1 EXIT NEXT gt 4 Usethe and keys to scroll through the choices CONTACTS SETUP and PRINTERS When a choice has been made press to advance to the next menu or press to return to the start up menu or the normal operating display 3 1 CONTACT PROGRAMMING The alarm contacts on the KTD 460s can be programmed for automatic camera call up site annunciation and preset camera positioning Each alarm contact input can be programmed to initiate any or all of these functions Before programming the contacts however it is important to understand the relationship between the contact number and the alarm input module number The KTD 463 assigns a numerical value to each contact connected to a KTD 460 based on the module s address 0 15 and the pin 1 16 each contact is connected to For example contact 2 on module 2 would be assigned a value of 33 See Table 2 to determine the contact number Table 2 Contact numerical values based on module number and pin Pin Contact Pin Contact Module Connection Range Module Connection Range 0 1 16 0 15 8 1 16 124 143 1 1 16 16 31 9 1 16 144 159 2 1 16 32 47 10 1 16 160 175 3 1 16 48 63 11 1 16 176 191 4 1 16 64 79 12 1 16 192 207 5 1 16 80 95 13 1 16 208
13. input modules are added to the system this procedure must be followed for the KTD 463 KTD 463 slave chassis is added to the system this procedure must be performed by the slave unit REPORT TROUBLE YES YES NO NEXT 6 The KTD 460 modules feature supervised contacts so the status level normal alarm trouble of each contact is continually monitored The menu above enables a global alert if any alarm contact is in a trouble state short in the line etc Use the and keys to enable or disable this feature If unsupervised alarm contacts were installed on the KTD 460 no resistors on the alarm contact line select NO for this feature applies for all contacts Note Trouble states are reported to external devices keypad controller Paragon GUI 22 1041310B March 2003 KTD 460 463 User Manual KTD 463 Programming 7 8 9 10 11 PROGRAM MACRO YES NEXT The KTD 463 can send custom Digiplex commands macros for special operational circumstances Up to 64 five step macros can be programmed Macro programming procedures are provided by the factory Unless directed to do otherwise by Kalatel technical support press or to advance to the next menu Note YES is inadvertently pressed on subsequent menus press until you return to the program macro menu PRINT SETUP REPORT YES NO NEXT This feature enables the user to print a report detaili
14. ng all contact programming information and KTD 463 setup information Press 5 to skip this and return to the main programming menu If you select YES the following menu appears ALIGN PAPER IN PRINTER EXIT NEXT This feature enables the user to manually align the paper on dot matrix printers prior to print PRINTING REPORT lt To abort the print job press When the print job is finished or aborted the screen will return to the main programming menu Programming is complete Press at the main programming menu to advance to the normal operating display section 4 Operation 1041310B March 2003 23 KTD 463 Programming Operation 4 OPERATION When the KTD 460 alarm input modules have been installed and programmed and the KTD 463 setup procedures have been performed the unit will begin operations The following appears on the LCD screen MODULE ADDR 00 PORT 01 The normal operating display shows the alarm input module address 00 15 which alarm port RS485 alarm input line the module is connected to 01 16 and the status of each contact The display will automatically scroll through each module every 2 to 3 seconds showing its status To pause the display press or To scroll another module press or The dashed lines arrows next to the alarm contact numbers represent each contact connection and indicate the following
15. on and should conform to local codes This manual provides installation and operation information To use this document you must have the following minimum qualifications A basic knowledge of CCTV systems and components A basic knowledge of electrical wiring and low voltage electrical hookups Use this product only for the purpose for which it was designed Customer Support For assistance in installing operating maintaining and troubleshooting this product refer to this document and any other documentation provided If you still have questions contact Kalatel Technical Support GE Interlogix Kalatel division Call 800 469 1676 Fax 541 752 9096 Note You should be at the equipment ready with details before calling Technical Support Conventions Used in this Manual Boldface or button icons highlight command entries The following WARNING CAUTION and Note statements identify potential hazards WARNING Improper use of this equipment can cause severe bodily injury or equipment damage CAUTION Improper use of this equipment can cause equipment damage Note Notes contain important information about a product or procedure This symbol indicates electrical warnings and cautions This symbol indicates general warnings and cautions 4 1041310B March 2003 KTD 460 463 User Manual KTD 463 Introduction 1 KTD 463 INTRODUCTION The KTD 463 desktop alarm is used in Digiplex systems fo
16. ort is available 24 hours a day 7 days a week Call Tech Support 800 469 1676 6 A M 5 P M PST Monday through Friday Tech Support 541 740 3589 all other times Main 800 343 3358 or 541 754 9133 Fax Tech Support 541 752 9096 available 24 hours a day Main 541 754 7162 Web www GE Interlogix com 1041310B March 2003 KTD 460 463 User Manual Table of Contents TABLE OF CONTENTS BEFORE YOU BEGIN 22m 4 1 KTD 463 INTRODUCTION ccce 5 1 1 PLACEMENT IN A SYSTEM Alan 5 1 2 INSTALLATION een 6 1 3 CONNECTING THE CABLES engen 6 1 4 CONNECTING THE PRINTER OPTIONAL 8 2 KTD 460 INTRODUCTION uuuuuuunnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn nn nn nn 9 2 1 PLACEMENT IN A SYSTEM curet netter 9 2 2 INSTALLATION o e 10 2 3 MOUNTING THE UNIT odiada 10 2 4 CONNECTING THE CABLES na lee 10 2 5 SETTING THE DIPSWITEH As Se 13 2 6 SUPPLYING POWER 14 3 KTD 463 15 3 1 CONTACT 16 3 2 PRINTER SETUP ed A is 20 3 3 SETUP MENOS Cds E ana 21 4 OPERATION acer 24 4 1 SHUNTED 8 24 4 2 PRINTED REPORTS ee eto ec ess 25 1041310B March 2003 3 Before You Begin KTD 460 463 User Manual BEFORE YOU BEGIN Read these instructions before installing or operating this product Note This installation should be made by a qualified service pers
17. plete all instruction steps before supplying power to the unit 2 3 MOUNTING THE UNIT Mount the unit on a wall or flat surface using the slots provided 2 4 CONNECTING THE CABLES Locate the removable terminal strips See Figure 8 and Figure 9 16 pin terminal strips 6 pin terminal strip o0o000000 o0000000000000000 000000 000000 0000000000000000 0000000000000000 000000 Cover screw 2 J PE Mounting flange 2 U J ET Power jack 10 position DIP switch LEDs Figure 8 Top view of KTD 460 10 1041310B March 2003 KTD 460 463 User Manual KTD 460 Introduction RS485 signal input signal output Figure 9 KTD 460 six pin terminal strip connections e Observe polarity when connecting the RS485 alarm cables e f voltage sources are used observe polarity when connecting alarm contacts 12 C 13 C 14 C 15 C 16 C IHHHHHHI Inputs Figure 10 KTD 460 16 pin terminal strip connections Figure 11 shows the two types of supervised alarm contact configurations for the KTD 460 normally open and normally closed 1041310B March 2003 11 KTD 460 Introduction KTD 460 463 User Manual Normally open configuration Normally closed configuration Alarm contact closed Alarm contact open Trouble break before resistor Trouble short before resistor Figur
18. r automatic camera call up site annunciation and preset camera positioning during an alarm event The KTD 463 operates in combination with KTD 460 alarm input modules each of which provides 16 alarm inputs Up to 16 KTD 460s can be connected to the KTD 463 via RS485 twisted pair cable for a total of 256 alarm contact inputs 1 1 PLACEMENT IN A SYSTEM The KTD 463 must be placed ahead of all other Digiplex components on the RS422 line With two KTD 463s one must be configured as the master and one as the slave The slave must be placed ahead of the master on the RS422 line A KTD 83 can be used to provide a return RS422 cable to the KTD 463 See Figure 1 and Figure 2 Keypad Video switcher KTD 83 RS422 RS422 Additional PTZ receivers E i EEEEH EEH S CyberDome RS422 RS485 1 1 KTD 460s 8 Pup iL Tl IL TIT TIL KTD 460s 8 463 Figure 1 System placement of one KTD 463 1041310B March 2003 5 KTD 463 Introduction KTD 460 463 User Manual Video Keypad switcher KTD 83 PTZ receivers RS422 RS485 mE r KTD 463 KTD 460 inputs KTD 463 KTD 460 inputs master 0 255 slave 256 511 Figure 2 System placement of two KTD 463s 1 2 INSTALLATION CAUTION Complete all instruction steps before supplying power to the unit 1 3 CONNECTING THE CABLES See Figures 3 through 5 1
19. r to print setup reports and hard copies of contact activity see Figure 14 Use the following steps to enable the printer Note Unless otherwise noted in the following menus when a selection has been made press to advance to the next menu or press to return to the previous menu 1 Select PRINTER on the main programming menu and press The following menu appears ENABLE PRINTER NO YES NEXT gt 2 Press to enable the printer Press to disable the printer if already enabled Pressing or will return to the main programming menu If the printer is enabled the following menu appears HANDSHAKE PROT NONE tl lt gt 3 Handshake protocol determines how data will be buffered by the printer or serial device Use and to select NONE or CTS RTS Check with the documentation provided with the printer or serial device for protocol requirements PRINTER BAUD RATE 9600 l lt NEXT 20 1041310B March 2003 KTD 460 463 User Manual KTD 463 Programming 4 This menu is used to set the baud rate of data transmitted on the RS232 serial line The default is 9600 KTD 463 maximum If the serial device requires a slower rate use and to select 1200 2400 4800 or 9600 5 Printer setup is complete Press to return to the main programming menu 3 3 SETUP MENUS When the alarm contacts have been programmed the alarm chassis can be programmed for oper
20. the alarm contact as normally open or normally closed CONTACT 000 MOD 00 01 VID ALRM YES 1 NEXT If a monitor is in the alarm mode and the Video Alarm feature is being used the camera site associated with the alarm contact will appear on the monitor screen when an alarm event occurs unless the monitor is disarmed for that site Use and to enable or disable the video alarm feature CONTACT 000 MOD 00 01 HOLD DLY 007 gt Each alarm contact can be programmed with a hold delay that will keep the alarmed site on the monitor screen for a specified period of time after the alarm condition has ended To use this function enter the desired hold delay time 00 14 seconds using the and keys To have the alarmed site display indefinitely scroll until hold delay time reads INF In this case a manual command is required from the keypad e g CLEAR ALARM to clear the site from the screen after an alarm event CONTACT 000 MOD 00 01 ANNUNC NO 1 NEXT 1041310B March 2003 KTD 460 463 User Manual KTD 463 Programming 7 8 9 10 If this setting is used an alarmed site will be annunciated at the keypad as a site call in when an alarm occurs For this function to be used the controller keypad must be programmed for annunciation as explained in the keypad installation and operation manual Use and to enable or disable annunciation A looping RS422 control cable