1. Biomedical Victoreen 451EXL 451 Assistant for Excel Users Manual February 2005 Manual No 1020040001 Rev 2 2004 2005 Fluke Corporation All rights reserved Printed in U S A All product names are trademarks of their respective companies Fluke Biomedical Radiation Management Services 6045 Cochran Road Cleveland Ohio 44139 440 498 2564 www flukebiomedical com rms Section 1 Section 2 2 1 2 2 2 3 Section 3 Table of Contents General Normal ON a av A renten A 1 1 Te lilo le aiei A E a m e e e ee 1 1 System Eileen ar 1 1 MAU li NOOCN GG ep e a oo 1 1 Customer Service Sales Technical SUpport kakaa kakaa aaa nana 1 1 Version OM AN OD EAEE 1 1 BUS Get lala ise AAA E o A A Aa 2 1 Installing the 451 Assistant for Excel ss 2 1 Configuring Excel to Run the 451 Assistant nan ennenn eneen enen 2 1 Uninstalling the 451 Assistant for EXCel akan 2 2 Using the 451 Assistant for Excel aaa aan 3 1 Connecting the 45 110 A PO masteren jaa 3 1 Starting the 451 Assistant for Excel ss 3 1 Beire POQOING pra oo pon 3 3 IME E De EEE 3 5 ODUONS aii ai eto i do neat o o A dk 3 7 Blank Page General Information 1 Introduction Section 1 General Information 1 1 Introduction The 451 Assistant for Excel is an Excel Add In An Excel Add In is a program that adds optional commands and features to Microsoft Excel The 451 Assistant provides remote control for many of the Mode
2. internal functions The total sample period is limited to 49 days Computer data logging is started by pressing the Start Log button Computer data logging is stopped by pressing the Stop Log button Virtual Instrument Display 32 Victoreen 451 EXL Operators Manual During data logging the Virtual Instrument Display shows the real time rate measurements from the 451 Also displayed are the alarm setting Acknowledge Alarm button and an alarm indicator Creation date 2 9 2001 11 11 51 AM Created by bjones Time Stamp mR h 2 9 2001 11 12 0 07 2 9 2001 11 12 0 06 AN 2 9 2001 11 12 0 06 2 9 2001 11 12 1390 2 9 2001 11 12 1340 2 9 2001 11 12 2400 Ta ZI amp Wo b gt 2 9 2001 11 12 1280 2 9 2001 11 12 1510 2 9 2001 11 12 390 2 9 2001 11 12 24 2 9 2001 11 12 98 2 9 2001 11 12 26 2 9 2001 11 12 141 1 2 9 2001 11 12 6 6 2 9 2001 11 12 5 6 2 9 2001 11 13 d 2 9 2001 11 13 2 33 Real Time Data Logged to Excel The different colors displayed in the data log shown above correspond to different alarm and alarm action levels Measurements that are below the alarm threshold are displayed in black Measurements that are above the alarm level and while the alarm is in an unacknowledged state are displayed in red Measurements that are still above the alarm level after the alarm has been acknowledged are displayed in yellow Measurements that are below the alarm level after an unacknowledged alarm state are d
3. the RS 232 cable into the 4 pin round connector jack on the side of the 451 3 Plug the female 9 pin cable connector into the 9 pin RS 232 connector on the personal computer If multiple connectors exist consult the computer s user manual to determine which connector to use 3 2 Starting the 451 Assistant for Excel The installation program should have installed the add in to Excel meaning that Excel will load the 451 Assistant automatically For more information about configuring add ins for Excel see Configuring Excel to Run the 451 Assistant Macros must be enabled in Excel for the 451 Assistant to work Select Enable macros when prompted Excel 97 and 2000 versions offer macro virus protection as an option With macro virus protection enabled Excel prompts the user whenever a workbook containing macros is opened If macros are disabled the 451 Assistant will not work Consult the Excel documentation for more information on macros in Excel 97 or 2000 versions The 451 Assistant Menu and Toolbar The 451 Assistant Menu and Assistant Tool Bar provide an interface for the user to remotely control the 451 configure the 451 download the internal data log start real time data logging and start an integrated dose measurement All of the menu items are described below Pz 451 Assistant E Disconnect Options o f Download log Pa p Start amp Stop 451 Assistant Tool Bar Lagging Properties Integrate D
4. workbook b Creates a line chart from the data selected on the worksheet Select the data you want to chart then click on the Chart button Chart 451 Connection Status Message Box ee 451 Connection Status Please walt while connecting to unit 451 Connection Status Message Box From time to time you will see the Connection Status message box This message box provides the user with feedback on the current operation and its status 32 Using the 451 Assistant for Excel 3 Data Logging 3 3 Data Logging Computer Data logging Once Microsoft Excel has been started and the 451 Assistant has been loaded data logging can be started and the data recorded in the active Excel worksheet When a measurement is performed the 451 Assistant automatically places the measured data in the active worksheet cell then moves down to the next row of cells where it will place the next measured data The 451 Assistant data logging properties may be accessed by clicking on the data logging E properties button Computer Data Logging Properties Sample every En second s For 1 hour s IV Enable Alarm at 50 mh Data Logging Properties The properties dialog allows you to set the length of time to record data and the time interval between recording data points The alarm level for computer data logging may also be set from the properties dialog NOTE Ihe time interval and ihe alarm level are independent of the 451s
5. data log interval is the period in seconds at which the 451 adds a new data point to its internal data log Clear Log Pressing the Clear Log button clears the contents of the 451 s internal data log Blink Alarm Enable Blink Alarm At A check in this box enables the Model 451 s blink alarm The blink alarm level and units may be entered in the boxes to the right SaveToEEPROM Saves the configuration to the permanent EEPROM in the 451 3Y Fluke Biomedical Radiation Management Services 6045 Cochran Road Cleveland Ohio 44139 440 498 2564 www flukebiomedical com rms
6. e communication port used by the 451 defaultis COM1 To change the communications port used click on the Use COM Port drop down box and select the desired port Click OK to start using that port Play Alarm Sound A check in this box indicates that the 451 Assistant will generate an alarm sound for every data point received by the 451 that is in the alarm state SEO Victoreen 451 EXL Operators Manual Configure Sound Opens the sound control panel which is used to configure Windows sounds To change the alarm sound select the Inovision 451 Alarm in the Sound Events list The name box will display the wave file currently used to generate the alarm sound Change the sound by typing the filename into the name box or select Browse to search for a wave file Pressing the play button in the sound control panel will play the sound in the name box Enable Acknowledge Alarm Functionality A check in this box enables the alarm acknowledge button during real time data logging Alarm State Colors The 451 Assistant can be configured to use 2 or 4 alarm states The four alarm states are normal acknowledged normal unacknowledged alarm acknowledged and alarm unacknowledged If Enable Acknowledge Alarm Functionality is not checked then only two alarm states are allowed alarm unacknowledged and normal acknowledged Alarm Definitions Normal Acknowledged The previous alarm has been acknowledged and the radiation rate is belo
7. isplayed in blue These alarm state colors and other alarm options may be changed through the 451 Assistant options menu Downloading the 451 s Internal Data Log The Model 451 is capable of logging data at a user defined interval from 1 to 255 seconds When the 451 has exhausted all of its data log memory logging is stopped until the user clears the data log memory To download the data log select a cell on a workbook to insert the log data then click on the Download log button Data download will begin immediately The assistant will download the entire data log stored in the 451 21 59 21 17 3 21 31 6 21 40 6 21 dE 21 2 ADDTT Sheet E I i 3 4 Using the 451 Assistant for Excel 3 Data Logging Downloaded 451 Data Log In the downloaded 451 data log shown above the first spreadsheet column is instrument temperature in degrees Celsius and the second column shows the measured dose rate 3 4 Integrated Dose The 451 Assistant can also be used to make integrated dose measurements The integration period can be specified for automatically timed integration or the user may control the integration and the 451 Assistant simply measures the integration period Click the Integrate button on the toolbar to open the integrated dose menu From this menu the user may set the integration timer length if one is needed then click start The 451 Assistant will then start the 451 in the run mode The 451 has a 30 second reset period after
8. l 451 s functions such as its internal data log and integrated dose measurement functions The 451 Assistant also provides real time computer controlled data logging in an Excel spreadsheet The 451 Assistant works with Microsoft Excel versions 97 and 2000 Since the 451 Assistant for Excel is an Excel Add In it is automatically loaded with Excel once it is installed 1 2 System Requirements The minimum system requirements are as follows e Windows 95 98 NT 4 0 2000 e Microsoft Excel 97 2000 e One serial port COM1 through COM4 1 3 Manual Addenda Any improvements or changes concerning the manual will be explained in an addenda included with the manual Be sure to note these changes and incorporate them into the manual 1 4 Customer Service Sales Technical Support For Sales and Technical Support contact Fluke Biomedical Radiation Management Services at 440 248 9300 1 5 Version Information The 451 Assistant version information can be viewed by clicking on About 451 Assistant in the Help menu About 451 Assistant X 451 Assistant for Excel Version 1 0 451 Serial Number 3836 Copyright 2001 Victoreen 451 EXL Operators Manual Blank page Installation D Installing the 451 Assistant for Excel Section 2 Installation 2 1 Installing the 451 Assistant for Excel Microsoft Excel must be installed on your computer before the 451 Assistant for Excel may be installed If Excel is not currentl
9. ou need to re enable the 451 Assistant do the following 1 Run Excel 2 If a worksheet is not loaded open a new worksheet 3 Select the Tools menu 4 Click on Add ins EZA Victoreen 451 EXL Operators Manual The Add Ins dialog box displays the add ins that are registered with Excel A check mark next to the add in means that the add in is loaded and will load automatically when Excel starts To unload the add in clear the check mark by the add in To load the add in check the add in If the add in is not in the list of registered add ins click the browse button to browse for the add in 5 Click OK 2 3 Uninstalling the 451 Assistant for Excel The 451 Assistant for Excel can be properly uninstalled by using the Add Remove Programs Control Panel Application Click Start Control Panel and open the Add Remove Programs application Select Inovision 451 Assistant for Excel and click on the Add Remove button NOTE The Add Remove Program control panel applet is the recommended way to uninstall all Windows applications e Using the 451 Assistant for Excel 3 Connecting the 451 to a PC Section 3 Using the 451 Assistant for Excel 3 1 Connecting the 451 to a PC To use the 451 Assistant for Excel the 451 must be connected to an unused serial communications RS 232 port To connect the 451 to a personal computer follow the steps below 1 Turn ON the 451 and the computer 2 Plug the 4 pin round connector of
10. ownload log Options 451 Assistant Menu Sel Victoreen 451 EXL Operators Manual Connect Opens the communications port and instructs the 451 Assistant to read configuration information such as the alarm settings unit type and ranges Disconnect Disables communications and closes the communications port Options Options The options dialog allows for the configuration of the 451 Assistants options In addition the 451 settings can be modified or viewed from the options dialog Some of the general options are setting the alarm sound the real time alarm acknowledge the real time alarm color and the COM port Some of the 451 settings are setting the blink alarm and the 451 logging parameters Start Real Time Data Log Starts real time data logging Real time means the 451 is connected to the computer during the entire logging process See real time data log properties for information about configuring real time data logging 2 Stop Real Time Data Log Stops real time data logging Er Real Time Data Log Properties Displays the real time data logging properties The sample interval logging duration and the real time alarm value are configured through this properties dialog d Integrated Dose Starts the 451 s dose integration process Download 4 Download Internal Data Log Starts downloading the internal data log from the 451 All data stored in the 451 is inserted into the active Excel
11. te will be inserted at the active worksheet cell in Excel as shown below E f R y 34 21 2018 381 k H Sheeti Sheet Sheets A Using the 451 Assistant for Excel 3 Integrated Dose Integrated Dose and Average Dose Rate The first worksheet cell A 1 contains the final integrated dose measurement of 34 2 mR or uSv the next worksheet cell B 1 contains the average dose rate for the integration time interval 2018 361 mR h or uSv h The measured units correspond to the instrument s default measurement units mR and mR h or uSv and uSv h 3 5 Options The 451 Assistants properties and a few of the 451s properties can be changed from the Options menu The options dialog contains two tabs the first tab labeled General contains options for the 451 Assistant the other tab labeled 451 Settings contains options for the 451 Options General Several 451 Assistant parameters can be changed from the general options menu including COM port and alarm configurations 491 Assistant U ptrons General 451 Settings Communications Use COM Port CMI General W Play alarm sound Configure Sound b Enable Acknowledge Alarm Functionality Alarm Stake Colors Normal Acknowledged Black Normal Uinacknowledged Blue Alarm Acknowledged Yellow Alarm Unacknowledged Red bd Cancel bune 451 Assistant General Options Menu Communications Is used to select th
12. tegrated dose for 30 seconds During this period the Integrated Dose status message box shows the Ee Victoreen 451 EXL Operators Manual time remaining in the 30 second reset period During this period any radiation detected by the 451 will not be included in the dose measurement Integrated Doze Please wait Far 30 seconds Time remaining 21 seconds Integrated Dose Status Message Box During Reset Step 4 After the 30 second reset period the 451 Assistant will display a status message box indicating that the 451 is integrating If timer controlled integration has been selected the 451 Assistant will indicate the elapsed integration time and the integration time remaining If timer controlled integration has not been selected the 451 Assistant will only indicate the elapsed integration time Stop can be pressed at any time to stop the integration process and read the integrated dose measurement Integrated Dose Integrating Far 1 minute II gt Time remaining 49 seconds Time integrating 11 seconds Integrated Dose Status Message Box During Integration Step 5 After the specified timer duration or stop is pressed the Assistant will query the instrument for the integrated dose Integrated Dose ES Querving instrument For integrated dose Please wait Integrated Dose Status Message Box Integration Complete After integration is complete the integrated dose measurement and the average dose ra
13. the run mode is started after which the instrument will start integrating After the stop button is pressed or the timer has expired the assistant will read the integrated dose from the 451 and insert the dose in the active cell and the average dose rate in the next cell to the right NOTE The average dose rate may be inaccurate at low integrate time samples The assistant cannot accurately determine the time length therefore the timer can be off by several seconds The following procedure demonstrates the process of making an integrated dose measurement Step 1 Click the dk integrate button to open the integrated dose measurement dialog box Step 2 Check the Use the timer to determine when to stop button to have the 451 Assistant control the integration period If this checkbox remains unchecked the user must press the Stop button to read the integrated dose Regardless of the timer setting the Stop button can be pressed at any time to read the integrated dose If the timer mode is selected enter the integration time then press Start to begin the measurement 451 Integrated Dose Measurement Ea To start integrating select the appropriate timer settings and click Start r Timer Settings IM Use the timer to determine when to stop Integrate For 1 minutes Integrated Dose Measurement Dialog Box Step 3 The Assistant will start the 451 in run mode After the run mode is started the 451 will reset the in
14. w the alarm level Normal Unacknowledged The previous alarm has NOT been acknowledged and the radiation rate is below the alarm level Alarm Acknowledged The alarm has been acknowledged and the radiation rate is above the alarm level Alarm Unacknowledged The alarm has NOT been acknowledged and the radiation rate is above the alarm level Options 451 Settings The 451 Settings menu contains information about the 451 currently connected to the PC These setting pertain to the 451 only and have no impact on the operation of the 451 Assistant These settings allow the user to change the configuration of the 451 451 Assistant Options General 451 Settings Mok Connected Lag Parameters Data log memory is cleared 7 Data log interval 1 to 255 dlear Log Blink Alarm _ Cancel foe 36 Using the 451 Assistant for Excel 3 Options 451 Assistant General Options Menu Serial Number Displays the serial number of the 451 that is connected Log Parameters Data Log Memory is Cleared Allows the user to select when the 451 internal data log should be cleared At Turn On Only The 451 will only clear its internal data log when the unit is first turned on At Turn On and integrate reset The 451 will clear its internal data log at turn on and at integrate reset Data Log Interval 1 to 255 The 451 is capable of storing measured rate data in its internal memory The
15. y installed on your computer INSTALL EXCEL FIRST The 451 Assistant for Excel can then be installed following the directions below NOTE Administrator rights are required to install this software on Microsoft Windows NT and Windows 2000 To install the 451 Assistant for Excel Start the computer Insert the 451 Assistant for Excel CD into the disk drive If the autorun doesn t automatically start then click the Start menu and choose Run In the Run dialog box type the following command D SETUP assuming that the CD is in the disk drive Three installation options are available erake JE e Typical Installs the files required for a typical installation e Compact Installs the minimum files needed for operation e Custom Allows the user to configure several installation options 5 Follow the instructions in each dialog box until the installation is complete and then click Finish 6 Read README TXT file A Readme txt file is copied to the installation folder Readme txt lists any changes to the 451 Assistant for Excel documentation since its publication It can be found on the CD Please consult the file for details and new information about installing the 451 Assistant for Excel 2 2 Configuring Excel to Run the 451 Assistant The installation software configures Microsoft Excel to run the 451 Assistant automatically whenever Excel is started If you do not want the 451 Assistant to be loaded each time Excel starts or if y