Home

en - sw configuration user manual

image

Contents

1. 23 e MEE NDS NET NETTE 23 9 ANNEX aoe ese NSH On n 24 9 T HSUOf tables mee aaa a A ee 24 9 2 HSO ANUS UAT ONS eraa a a A a 24 LAREER s On the documentation PDF UCS Take action Note x AN WARNING Please read this chapter carefully before working with this documentation and the User Configuration Software 1 1 Function of this document This user manual instructs the machine operator s technical personnel in the operation of the User Configuration Software for Pharo safety laser scanner It does not provide instructions on the operation commissioning and maintenance of the protective devices themselves Please refer to the documentation enclosed with the pro tective devices for information on operation commissioning and maintenance 12 Target group This software documentation addresses planners developers and operators of systems that are to be protected by one or more Pharo scanners It also addresses people who integrate these protective devices into a machine carry out machine commissioning or who are in charge of servicing and maintaining the unit 1 3 Depth of information This software documentation contains information on the User Configuration Software for protective devices supplied by REER S p A The user manual provides an overview of the basic software functions Please refer to the online help function for
2. PHARO User Configuration Software UCS USER MANUAL pharo reer it 8540588 Rev O 15 07 2004 LAREER vs This document is protected by the law of copyright whereby all rights established therein remain with the com pany REER S p A Reproduction of this document or parts of this document is only permissible within the limits of the legal determination of Copyright Law Alteration or abridgement of the document is not permitted without the explicit written approval of the company REER S p A 2 8540588 Rev O 8540588 Rev O Contents Onthe documentation Pe 4 LA SPURCUONZOT EISHAOCUMIC I nenna aa eens 4 te Wail COU BLOU Dantes tact mute Bedcadesanyaaenaie a a a 4 LS DO OEM OF IVLOM OPI siasscaahavocseniessenqnscusivnciataceassaqneeatideoceressucmeuntansdinalauseweiarossauseauetacs 4 TA SAO OFOV ATION S ranae E 4 1 5 Symbols and TOMAS USEC s ooo ceo di m ER GR D ERR UIN Or on pO SP Ce PIER adr eds 4 1 6 Accessing the documentation ssi aoo hs Keele a eo Re keel Sos 5 Lr USING iheonlnmne elp TUctlolssa umi e eese Diecast o Rei re etd cocti oed Duce a teu en eis 5 1S HOW to Uuse this documen essassescdsiittussp iei dute Sun ood owkes ebat cet ar SUC dura iu PERO Gate eoi Dons T Installation of the software sssssssnssessssnssssnsenenssnesssneenensenensenenneneenensneneenenneneenenenneneenenneseneenenes 8 PHOGUGE COSC ICON Ne 9 A User interface rrinin a a 10
3. been computed by the PC on which the UCS runs REER S p A is therefore unable to warrant that no computer specific computing errors will occur LAREER ws User interface Fig 8 User interface of the UCS 10 How to start the software Go to the Start menu and select the command Programs REER Applications REER UCS The User Configuration Software will now be started Once the program has started the screen is initially blank Device combinations saved or identified will thereafter be shown graphically in the user interface These can then be used to configure or perform diagnostics on Pharo Title bar Menu bar Toolbar a Project Edit View Extras 7 Dig pns Machine operato D Z Navigation area Viewing area Status bar The user interface includes title bar menu bar toolbar the navigation area the viewing area and the status bar How to close the software gt On the Project menu choose the Quit command The program window will be closed If at this point you have as yet not saved the data of an open project you will be prompted to do so 4 1 Menu bar toolbar and status bar The menu bar and the toolbar are found at the top of the software window The menu bar includes the commands for the fundamental operation of the software whereas the tool bar provides the most important commands in the shape of buttons Moving over a button will open a brief information tag tool tip on the functi
4. it easier for you to navigate through created projects device configurations dia gnostics reports etc the program creates a directory structure in the directory chosen during installation This directory structure consists of sub directories for the individual types of files that you are allowed to save in the UCS e backup This directory holds the program files of an earlier version saved after an update You must not save any other files in this directory device specific directories This directory includes sub directories that are suggested as the directory when saving device specific files e g diagnostics report or configuration protocol import export UCS defaultfor importing and or exporting configuration drafts projects UCS default for saving project files e system This directory holds the system specific UCS files You must not save any other files in this directory 13 LAREER s Working with projects Notes AN WARNING 14 The devices which you configure maintain or perform diagnostics with the UCS are managed in projects and shown in a project tree Using the UCS you can assemble projects offline and then configure and save them In this way for example for the initial configuration of laser scanners for a plant you can first plan the configuration on the screen and later transfer it to one or more Pharo scanners When the project is created it is given a name that you can
5. more detailed instruc tions on the configuration of devices and performing diagnostics Planning and using protective devices also require specific technical skills which are not detailed in this documentation 1 4 3 Abbreviations Portable Document Format for Adobe Acrobat Reader REER User Configuration Software 1 5 Symbols and formats used Instructions for taking action are shown by an arrow Carefully read and follow the instruc tions for action Refer to notes for special features of the software or of a device Software notes show the location in the UCS where you can make the appropriate settings and adjustments Warming Warnings indicate real or potential hazards and risks They are designed to prevent physical injury or death Carefully read and follow the warning notices 8540588 Rev O Fig 1 List of contents of the online help 8540588 Rev O LAREER s 1 6 During the installation of the individual software components the related operating instructions for the device are also installed You can access the operating instructions from the UCS online help Accessing the documentation In addition you can also open the operating instructions directly from the installation CD How to open a set of operating instructions Start your PC and place the installation CD in your CD ROM drive The installation wizard will start automatically First enter the serial number for the UCS You will f
6. set for another country than the available languages e g Dutch the Select language dialog box appears before the REER User Configuration Software dialog box Select the desired language e g English During the installation of the UCS choose the software components to be installed Components that have already been installed with a previous version of the UCS are selected automatically and updated as necessary If Windows does not start the installation wizard automatically Click Run in the Start menu Enter the following command line in the Open field Drive letter for your CD ROM drive Setup exe The Serial number dialog box will open 8540588 Rev O LAREER s Product description Note Tab 1 Typical procedure in the UCS 8540588 Rev O AN WARNING PHARO safety laser scanner can be configured differently depending on the application and operating mode The User Configuration Software has a graphic user interface which allows you to configure and diagnose PHARO The para meters for a configuration are transferred to the device and saved there The software is not suitable for the configuration and diagnostics of devices supplied by other manufacturers The devices in the UCS are always displayed in so called projects The User Configuration Software allows you to e create a new project configure the devices and later transfer the configuration to the devices You can then save the project cr
7. 4 1 Menu bar toolbar and status bar lsseeessseeeseeeee enne nnns 10 4 2 Navigator and vieWITB aleae a E E E unde ood ete diacru cx T1 4 3 elecilig the JallgllaBE anexos een eadera se ve vuv cnexta dye vvv oec deni resp cad c ra deae x ms ee 12 4 4 Keyboard cotmitigtildskisnsiwosabekasau ep biu tata tn Qoi Tx Date pha d qd tmb de SFR ub RU unis 13 4 5 Directory structure for the program uiui aeta notio depo ape R Ud adde a bk t oo deb ra baud etd ados 13 9 Working with projeCisSssrisisinna cn iHa CEU CREE S tM PE Roa MUR M RUE DuEN SENEC NE ENEE SU SUE MESURE GRECE 14 oL Nepre LGC ER nn eNO T nT a ba Ge va sot rue 16 5 2 Changing prolecEnalTiesS ucdistesesnioscexo pe tese c tia ez cembris E EE OEN 16 53 Compating WARN A DIOJeGE THO ecco nuzdunt netur ive eu Govevup nci Uma tasca HE Ee api TrdnNS 16 94 A0dNE CG CVICCS susie M M remne 17 SO el 2 6 21 0 2 S TEES ree a 17 EB enlm 18 rab CORTE UAC me 19 AL FPlecards or Wz seo datudku bei quss dd nwacs lume tinxit Ubunstra basnbnesads Constit dus Da ubae 20 1 2 SOMMEULA HOM Dl OLO COI lesre retentu ooaitera kr estu cenaas e 21 os quesee T c 22 TA Change prolecr pasSWOEG c usum dic torus har oca Ur E RAD E ae ug uo dba cU DE E aa un EA UU 22 F ESEE Wee 22 alleittue ionic
8. If you leave the PC unattended when it is connected to devices you must change to the Machine operator user group in order that no unauthorised WARNING persons can transfer configurations to the devices Detailed instructions The descriptions in the online help explain the functions and relationships in the dialog boxes Use the Detailed instructions button in the descriptions to go to the step by step instructions of the online help Fig 3 Detailed instructions button If several sets of step by step instructions are available the Topics found dialog box is opened Choose there the required topic and click the Display button Fig 4 Topics found dialog box ow to edit a configuration draft How ta export a configuration draft How to import a configuration draft How t receive the configuration fram the devices How to transfer the configuration ta the devices 6 8540588 Rev O Fig 5 Example step by step instructions Fig 6 Device specific subjects link Fig 7 Contents button 8540588 Rev O LAREER s The step by step instructions describe the related procedure in detail How to receive the configuration from the devices Using the right mouse button open the context menu of a device or system On this menu choose the command Configuration draft Receive The previous configuration af all devices is read and can be edited in the UCS As the UCS is used for the configura
9. addition you must specify one COM port of your PC as the connection for the devices Also from the connections available on your PC select the one where the devices are con nected The connection you select must not be used by any other peripheral e g a mouse If you do the system will not function correctly 8540588 Rev O LAREER s Configuration AN WARNING Note Fig 17 Status bar with check mark for configuration verified 8540588 Rev O Note Using the UCS you can configure the Pharo safety laser scanners Plan your configuration carefully The configuration of Pharo must be carried out with the greatest accuracy and must match the status and the condition of the machine or system to be monitored Incorrect configurations can result in injury or death Always begin the configuration by creating a new configuration draft in the UCS or by editing a configuration draft received from the devices Generate or edit the configuration draft either with the help of the configuration wizard or in a configuration dialog box with file cards For the actual configuration of Pharo transfer the configuration draft to the connected devices After sending the configuration draft a configuration protocol will be displayed which you must first release before the configuration is enabled in the devices You can transfer the configuration draft to devices or a device system only if your PC is connected to the de
10. are shown in colour Active means that the device has a complementary unit to which a L connection has been made via the interface and that the comple mentary unit has been identified by the UCS Passive devices are shown in grey ym Passive means that there is at present no connection to this device either because it is currently disconnected or because it could not be identified You can identify the device to which the PC is connected by the ap device symbol showing a PC Unknown or unidentified devices are shown with a question mark 9 i The device status is symbolised by the colour of the lettering Font colour Meaning Configured devices are shown with blue lettering REER protective device Non configured devices or devices in which a malfunction REER protective device has occurred are shown with red lettering Devices where the UCS is unable to identify their status FEER protective device not connected not identified are shown with grey lettering 5 2 Changing project names You can change the name of a project When a project is saved the UCS uses the project name as the default file name For the project name use names for instance with which you can allocate your projects to the machines or plant that are protected 5 3 Comparing with a project file You can also compare a project saved and or opened in the UCS with a saved project file A dialog box will show the s
11. aved project on the left and on the right a comparison protocol In this dialog box you can open the project file compared with the open project 8540588 Rev O 8540588 Rev O LAREER s 5 4 Adding devices If you have created your own project in the UCS you can also add one or several devices The device selection wizard will assist you in this step Added devices can be deleted again from the project The commands necessary to carry out the above described functions are found in the con text menu of the project Please refer to the online help for detailed instructions 5 5 Properties To check the type codes and the serial numbers of the devices you can display the properties of a project and or the properties of a single device The list shows all type codes and the serial numbers of the devices 17 LAREER ws Communication Fig 16 Selecting the communication protocol Note 18 The software communicates with the devices via a cable link To make sure that the data communication between your PC and the connected laser scanners functions correctly you must select a communication protocol On the Extras menu of the UCS you will find the Communication connection command Please refer to the online help for detailed instructions Communication connection Prataen Serial communication AK 512 OF Cancel Help Choose the communication protocol Serial communication RK 512 In
12. b 4 9 2 Fig 1 Fig 2 Fig 3 Fig 4 Fig 5 Fig 6 Fig 7 Fig 8 Fig 9 Fig 10 Fig 11 Fig 12 Fig 13 Fig 14 Fig 15 Fig 16 Fig 17 Fig 18 Fig 19 List of tables Typical procedure in the UCS vagcceib veweelicnsccinecases aan Gddasnsedsnxattecasewebainsieicbieaceursneneasuvanccians 9 FUNCTION keys and KEY SMOLICUIS sitixcsiwaciuawsnasdaddicewsy EE eos Yam dau EEEa 13 Meaning of the SymbolSuas siete etate Pda reete ore dora to EEUU cob cence 16 Meaning OF THE TOME COlQUI S ateses tenet cent ie ia sees peint Dee ra in eoe prine c eaae 16 List of illustrations List of contents of the online help eese nnns 5 Example for the description of a UCS dialog box eeeeeeeeeeeeessee 6 Detailed Mstructions DULOM srasni vetus imus a qua Xue bus Gute Rue EE ANA Cos ee vr Pau Sa t etl 6 fejsjfe wrolaremeliziissduo Pe mH 6 Example step by step instructions 11er nnn nnne T Device specific subjects Ihk iuiiieeii secre cite ico ae Sitio cu cade eR ee rn Contem DUUUGO aisia a SBE eye ae ee or Tone en ee eee er eee Seer T USErInteMace Of the UC S t PL Tm 10 Menu Dar wIthitool TID iranin a at a rated we aa 11 Status bar with symbols for connected and configuration verified 11 Status bar with symbols for not connected and configuration not VI dioe TRUM TT Exam
13. change Add devices to the project tree of a new project A second way of creating a project is to have the UCS identify devices already wired up In this way a project with all identified devices is displayed in the navigation area of the UCS The commands necessary to carry out the above described functions are found in the Project menu Please refer to the online help for a device specific description and detailed instructions e During project identification the software only identifies the type of devices connected and identifies these To ensure that you receive the configuration of the connected devices in the UCS the software will prompt you to receive the current configuration This is important as otherwise an empty configuration draft is displayed by the UCS and not the configuration draft that was transferred to the device connected during earlier configuration Once the configuration has been received you are prompted as to whether you want to change to a different user group You can only later transfer a new or changed configu ration draft if you change to the Authorised client user group Check identification of the devices Check to make sure that all devices in the project have been correctly identified Compare the devices connected with the data in the viewing area for the UCS You can save the projects in files and open them again later Only one project at any one time can be opened in the UCS If a project is ope
14. click the Help button in the dialog box or press the F1 key The related description for the dialog box is then displayed automatically LAREER s Fig 2 Example for the de scription of a UCS dialog box User groups There are various user groups in the devices from REER S p A These user groups have different authorisations e g for transferring configurations to the devices or to perform diagnostics on the devices If the devices in a project have been identified by the UCS or the UCS is linked to the devices for a project you can change to these user groups When the UCS is started you will automatically belong to the user group Machine operator To be able to send configurations log in with the device or the device system as Machine maintenance personnel or as Authorised client using the appropriate project password The factory set password REERSAFE has been entered for the user group Authorised client If you wish to secure access to the confiquration of the devices you must change this passwordin each configured device Note If a device cluster has been assembled using devices which have already been configured the individual devices may have different passwords In this case you will be asked for your password separately for each device Once you have entered the correct passwords for all devices the password for the first device will be assigned to all devices Change to the Machine operator user group
15. eated identify devices connected to the PC and receive the existing configuration of the devices and then transfer it back to the devices In this way a new project is created in the UCS that you can save e open a project saved previously and transfer the configuration to devices of the same type with the same type code and for the same application The configuration of the devices is password protected with the effect that only the members of the appropriate user groups will be able to transfer configurations to the devices You can also use the User Configuration Software to perform diagnostics on connected devices e g in the case of an error The diagnostics data will be displayed on the monitor e Connect PC to e Add device s e Connect to device s device s Create configuration e Logon e Receive configuration Connect to device s e Transfer configuration e Logon Log on e Edit configuration Transfer configuration e Transfer configuration Save project e Save project Test the devices for operational readiness The software is unable to determine if a device is mounted operationally or not Once you have successfully transferred the configuration drafts check to see if the Pharo safety laser scanner actually monitor your machine or system the way you intended In this case pay attention to the instructions on commissioning and for the daily check in the operating instructions for the related device All values have
16. ind the number on the booklet with the installation CD Then go to the REER User Configuration Software dialog box and select under Read documentation the required operating instructions and click the OK button beside the selection Acrobat Reader will open Accept the licence agreement The selected operating instructions are opened 1 7 The UCS is available with an online help function which provides information on the soft ware functions and which provides a step by step description of the individual actions Using the online help function The online help has a table of contents and an index The following sections of the docu mentation can be opened in the list of contents for the online help e user manual on the UCS in Portable Document Format PDF e online help on the UCS e online help on device specific subjects e g configuration procedures e operating instructions for Pharo in Portable Document Format PDF IL User Configuration Software C Manual C On the documentation AR User interface 2 x toolbar and status bar Navigation and viewing area Printer setup 2 Selecting the language 2 Keyboard commands Directory structure for the program C Working with projects g gt Configuration C Diagnostics data dia The online help function can be opened separately using the command Programs REER Applications Help on REER UCS or in the UCS in the menu From one of the UCS dialog boxes
17. l then be available The navigation area of the UCS can no longer be used After the configuration data has been transferred to one or several devices the configura tion protocol will be shown automatically During this process the actual data is read out from the device and displayed If the data read does not match the data in the configuration draft it will be shown in black If the data read out differs from that in the configuration draft it will be shown in red In this case the configuration protocol cannot be released You can print and save the configuration protocol You can also insert a comment via an additional dialog box This comment will also be printed and saved Carefully check the configuration protocol Carefully check to make Sure that the configuration data displayed comply with those you actually wanted to enter Check for typing and transfer errors Once you have successfully transferred the configuration the machine or plant must be checked and released by specialist personnel e The new configuration will be activated on the device only after release If you reject the configuration then the device or device cluster receives an invalid configuration The commands necessary to carry out the above described functions are found in the Project menu and in the context menus of the devices Carefully check each individual item of the configuration protocol Some configuration protocols for devices have seve
18. ll find explanatory text on the individual configuration steps in the related dialog box e The file cards allow you to specifically change one or several configuration parameters Check the content of all file cards Unlike the configuration wizard in the file card view you are not automatically guided through all configuration points For this reason check the content on all file cards to ensure that the configuration data matches your application The commands necessary to carry out the above described functions are found in the View Dialog box menu A system with several devices for example a cascaded system is in general configured in one single configuration wizard or one single dialog box with file cards Several runs through the setting dialog boxes will be completed resp the file cards will be repeatedly offered Device selection wizard for PHR Step 1 Entering the type code fe With wizard Direct entry Using the wizard you define step by step the type code with direct entry you enter the code manually Back Cancel Help 8540588 Rev O Note AN WARNING Notes x Fig 19 Buttons for paging through the configuration protocol 8540588 Rev O LAREER s 7 2 Configuration protocol As soon as the configuration protocol or the view containing the configuration draft is dis played the standard menus in the software are hidden Only the Project menu with the appropriate buttons wil
19. n while opening or creating another pro ject the original project will be closed When you open an existing project or add a new project then you should connect the de vices displayed to the devices connected By connecting you will be able to verify that the connected devices and the devices shown in the project tree have matching type code You can also compare a project saved and or opened in the UCS with a saved project file In addition you can open a list showing the properties of a project or of a single device 8540588 Rev O LAREER s How to connect the PC to PHARO Connect the 9 pin SubD plug of the connecting cable to a serial interface of your PC Fig 15 Connection of the PC to PHARO Remove the protective cap on the configuration socket of Pharo Connect the M 8x4 plug to the configuration socket of the device and or the device cluster Notes X Ensure that the configuration cable is not laid in close proximity to high power electrical drives or cables carrying high power In this way you will avoid EMC effects on the confi guration cable 8540588 Rev O 15 LAREER s Tab 3 Meaning of the symbols Tab 4 Meaning of the font colours 16 5 1 The project tree The project tree of the devices is shown in the navigation area The devices existing in the project tree can be displayed in the active or in the passive mode Example symbols Meaning Active devices
20. nadequate 11 LAREER s Fig 13 Navigation area left and viewing area right of the UCS Fig 14 Status bar with Note symbols for connected and configuration verified 12 Note REER UCS olea ai Project 1 H Ej Fharn system EHE Pharo 1 General Parameter Value p General p Control inputs p Outputs p Field sets p Monitoring cases Application name Serial number Scanner Serial number 0 module Serial number System plug Sofware version Counter Sofware version Controller Software version Interface Device classes control category Mechanical design sensor head Software package safety Solution 01010001 01010001 01010001 Dn nr 00 00 Dn nr Laser scanner Type 3 standard housing Range 4 0 m Basic package KO module VO module software package Housing type special housing Fhara PHR 332 Basic package Basis device incorrect Machine oper ator General The viewing area is located to the right next to the navigation area and is initially blank In the viewing area of the UCS e the diagnostics data is displayed when you have performed diagnostics e the configuration protocol is displayed when you have transferred a configuration to a device e the parameters for a device are displayed when you click one of the device parameter nodes e the configuration data currently in the UCS is displayed when you display the co
21. nfiguration draft for a device Only when it is indicated in the status line that the UCS is linked to the connected devices and that the configuration draft is verified it is ensured that the data displayed for a parameter node or the configuration draft matches the data in the devices You can change the size ratio of navigation area and viewing area 4 3 Selecting the language The UCS can be operated in two languages Italian or English Select the appropriate lan guage in the Extras menu The project tree and the context menu of the project tree will change its associated lan guage only after a new project is generated or after a project has been identified or opened 8540588 Rev O Tab 2 Function keys and key shortcuts 8540588 Rev O LAREER s 4 4 Keyboard commands The UCS allows you to execute frequently used functions via function keys or with key shortcuts Function key or shortcut Ctrl N Ctri O Ctrl S F1 F3 shift F3 F4 F6 F7 F8 Alt F4 Esc Description Create new project Open existing project Save project Open the help utility Identify connected project Select communication connection Link connected project with open project Display properties of a project or device Open the context menu Change user group End UCS Close dialog box without saving Cancel 4 5 Directory structure for the program To make
22. of the Pharo and the number of the device counter Device counter nr Both numbers can be found in the Reset password dialog box When you reset the password for a device it is configured as on delivery For operation to be possible you must re edit the configuration as delivered or transfer a suitable previous ly saved and verified configuration to the device 8540588 Rev O LAREER s Diagnostics data 8540588 Rev O Note With the aid of the UCS you can perform diagnostics on devices connected and linked to the UCS or identified by the UCS To do so load the diagnostics data to the viewing area of the monitor As soon as the diagnostics data is displayed the standard menus of the software will dis appear Then only the Project menu and the related buttons are available The navigation area of the UCS can no longer be used You can print and save the diagnostics data You can also insert a comment via an addi tional dialog box This comment will also be printed and saved The commands necessary to carry out the above described functions are found in the con text menu of the devices under Diagnostics Please refer to the online help for a specific description and detailed instructions 8 1 Comments You can add comments to the reports displayed in the viewing area of the UCS These comments are also printed with the appropriate report and saved 23 LAREER s 24 Annex 9 1 Tab 1 Tab 2 Tab 3 Ta
23. on of the button 8540588 Rev O Fig 9 Menu bar with tool tip Fig 10 Status bar with symbols for connected and configuration verified Fig 11 Status bar with symbols for not connected and configuration not verified Fig 12 Example of a context menu Note 8540588 Rev O LAREER s Project Edit View Extras 7 Zea r Look 1 vis Save project Cr The status bar is at the bottom of the software window There the following is displayed e the status of the program execution and progress if the action is protracted e the user group to which you currently belong e the name of the project or device in the navigation area e whether the UCS is connected to a device e whether the configuration has been verified The toolbar and the status bar can be shown or hidden 4 2 Navigation and viewing area The navigation area shows the devices in a device cluster hierarchically in a project tree This project tree consists of a project symbol and one or several device symbols In the navigation area you can open various commands using the context menus for the project or the devices Project Edit View Extras ala Fraject 1 EA Pharo system Fite fj Diagnostics Delete device Properties If some commands are only displayed in grey then the commands are currently not avail able because the UCS for example is not connected to a device or your access rights are i
24. ple of a context Me MU cei eoe sables o ER e One eo Ue ave cenr te Deer eoe da pde Aa 11 Navigation area left and viewing area right of the UCS 12 Status bar with symbols for connected and configuration verified 12 Connection ore PC to PHAR O sotnia ee rea i es nautae hen Pea reina 15 Selecting the communication protocol ccccccccseeesseeeeeeeeeeeeseeeeeeeesseaseeeeeeeesseaees 18 Status bar with check mark for configuration verified esssuse 19 Dialog box for the configuration wizard eeeeeeeeeeeeeee nennen nnne 20 Buttons for paging through the configuration protocol 21 8540588 Rev O
25. ral pages In this case page to the previous following pages using the buttons at the bottom of the scroll bar or using the Page up Page down keys A B Also carefully check the following pages of the configuration protocol The Release but ton only becomes available when you have paged through to the last page of the configu ration protocol Click the Release button The configuration data will be loaded to the device devices and initialised with the new configuration If the loading has been successful an appropriate message will appear Click the OK button The configuration loaded to the device devices is now active Test whether the device s monitor the machine or plant as you expect Only after com pleting this step go to real time operation 21 LAREER s Note AN WARNING Note 22 7 3 User groups There are various user groups in the Pharo safety laser scanners These user groups have different authorisations e g for transferring configurations to the devices or to perform diagnostics on the devices If the devices in a project have been identified by the UCS or the UCS is linked to the de vices for a project you can change to these user groups When the UCS is started you will automatically belong to the user group Machine operator To be able to send configura tions log in with the device or the device system as Machine maintenance personnel or as Authorised client using the appropria
26. te project password The factory set password REERSAFE has been entered for the user group Authorised client In order to protect the access to the configuration of the devices you must change this password If a Pharo cluster has been assembled using Pharo scanners which have already been configured the individual devices may have different passwords In this case you will be asked for your password separately for each device Once you have entered the correct passwords for all devices the password for the first de vice will be assigned to all devices Change to the Machine operator user group If you leave the PC unattended when it is connected to Pharo you must change to the Machine operator user group in order that no unauthorised persons can transfer configu rations to the devices 7 4 Change project password The user group Authorised client can enter change the passwords for the user groups Machine maintenance personnel and Authorised client The passwords will be saved in the devices This allows the scanners to be protected from being configured by unauthorised persons 4 5 Reset password If you have forgotten the password for a device you can reset the password To do so you need what is called a reset password You will get this password once you have identified yourself in writing to the manufacturer For this purpose use the form Faxform pdf on the UCS CD ROM For the identification you will need the serial number
27. tion and diagnostics on the safey laser scanners of the Pharo series along with the basic description there are device specific help subjects From these basic descriptions you can open the device specific help subjects using the Device specific subjects link at the end of a dialog box description H Device specific subjects The Contents button in the dialog box descriptions and in the step by step instructions will always take you back to the list of contents Once back in the list of contents and in the appropriate dialog box descriptions you can also open the operating instructions for the desired protective devices To do so you must have the related file in PDF format and Adobe Acrobat Reader in stalled on your PC If this is not the case a warning is displayed 1 8 How to use this document After you have carefully read the above sections please note the following notes on the document e f the software is as yet not installed please read the chapter Installation in this user manual If you are working with the software for the first time please read the chapter Product description If you are familiar with the software and want to configure devices please read the chap ter Configuration If you are familiar with the software and want to perform diagnostics on devices please read the chapter Diagnostics LAREER s Installation of the software Note Notes An installation wizard will guide you thro
28. ugh the installation of the software Before begin ning the installation close all other programmes The minimum system requirements for the operation of the User Configuration Software are e standard Intel Pentium PC 233 MHz 64 MB RAM e spare hard disk space UCS 15 MB documentation 100 MB e graphics resolution 800 x 600 pixels with High Color 16 bit e RS 232 serial interface that is not used by any other programs e operating system MS Windows 95 98 NT4 0 2000 XP e a printer driver of your choice must be installed During the installation you can install Acrobat Reader Using this program you can read the user manual for the UCS and the operating instructions of PHARO How to install the UCS Start your PC and place the installation CD in your CD ROM drive The installation wizard will start automatically It allows you to open the documentation and to install the software First enter the serial number for the UCS You will find the number on the booklet with the installation CD Then go to the dialog box REER User Configuration Software and select Install software REER UCS and click the OK button beside the selection Follow the instructions in the installation wizard e The UCS and the installation wizard for the UCS are available in two languages The soft ware detects the regional settings in your operating system and starts the wizard in the related language However if your operating system is
29. vices and if you are registered as user in the appropriate user group of the devices The configuration draft of a single device can also be exported and imported to other Pharo devices with the same type code Verified configuration draft As soon as a configuration draft has been sent and released by an Authorised client it is deemed to be verified You can see this by a green tick or check in the status bar The project with the verified configuration draft can then be saved and later be opened and sent also to other devices by the machine maintenance personnel When a project is opened the green check mark in the status line is only displayed after the UCS is linked to the related device If the open configuration draft is changed a red cross appears in the status line The confi guration draft can no longer be transferred by machine maintenance personnel The commands necessary to carry out the above described functions are found in the con text menus of the device symbols Please refer to the online help for a device specific de scription and detailed instructions 19 LAREER ws AN WARNING Note Fig 18 Dialog box for the configuration wizard 20 7 4 File cards or wizard You can create the configuration draft either with the help of the configuration wizard or with the file cards e The configuration wizard will guide you step by step through the configuration from the first to the last setting You wi

Download Pdf Manuals

image

Related Search

Related Contents

PDF  Manual do Usuário - TMED  User Manual  Évaluation du trouble déficit de l`attention / hyperactivité  Descargar  Ariston AS 150 Technical information  ARRIFLEX D-21 Manual    PowerFlex 20-HIM-A6 / -C6S HIM (Human Interface Module) User  Lire la suite - Les Oies du Capitole  

Copyright © All rights reserved.
Failed to retrieve file