Home

Manual MAXinBOX SHUTTER 8CH v1.0 Ed.a

image

Contents

1. ETS PARAMETERISATION Prior to setting the scene temporisation it is necessary to have one or more scenes configured in some of the channels When entering the Configuration window under Scene Temporization all configured scenes will be listed together with a few checkboxes to select which of them need to be temporised as shown in Figure 4 d GENERAL Scene Number 12 Ed OUTPUTS Channel A Scene Number 23 Channel D 4 Scene lemporization CONFIGURATION Scene Number 12 Scene Number 23 Manual Control Figure 4 Scene Temporization Enabling a certain scene number n brings a new tab with such name to the menu on the left from which it is possible to configure the temporisation of that scene for each of the channels where it has been configured GENERAL OUTPUTS Channel A Channel D 4 Scene Temporization CONFIGURATION scene Number 12 s Scene Number 23 i Manual Control dd Scene 1 Channel A Delay A in 4 dd Scene 1 Channel D Delay 0 4 Figure 5 Configuration of Scene Temporization http www zennio com Technical Support http zennioenglish zendesk com 12 Zennio MAXinBOX SHUTTER 8CH Therefore parameter Scene m Channel z Delay defines the delay that will be applied to the action defined in channel z for the execution of scene m The range of this delay is O to 3600 seconds 0 to 1440 minutes or 0 to 24 hours http www zennio
2. DPT_ Trigger DPT_ Trigger DPT_ Trigger 0 1 0 1 0 1 0 1 0 100 0 100 0 100 0 100 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 Cx Stop O Stop 1 Stop Cx Lock O Unlock 1 Lock Cx Rise Relay Status O Opened 1 Closed Cx Lower Relay Status O Opened 1 Closed Cx Shutter Position Status 0 Top 100 Bottom Cx Slats Position Status 096 Open 100 Closed Cx Shutter Positioning 0 Top 100 Bottom Cx Slats Positioning 096 Open 100 Closed Cx Alarm O No Alarm 1 Alarm Cx Alarm O Alarm 1 No Alarm Cx Alarm 2 O No Alarm 1 Alarm Cx Alarm 2 O Alarm 1 No Alarm Cx Unfreeze Alarm Alarm 0 Unfreeze 1 gt End Alarm Cx Move Reversed O Lower 1 Raise Cx Direct Positioning O No Action 1 Go to Position Cx Direct Positioning 2 O No Action 1 Go to Position Cx Direct Positioning Save O No Action 1 Save Current Position Cx Direct Positioning 2 Save O No Action 1 Save Current Position http www zennio com Technical Support http zennioenglish zendesk com 15 Zennio Passion for KMX innovation Join and send us your inquiries about Zennio devices http zennioenglish zendesk com Zennio Avance y Tecnologia S L C Rio Jarama 132 Nave P 8 11 45007 Toledo Spain Tel 34 925 232 002 Fax 34 925 337 310 info zennio com KNX CE RoHS
3. Zennio Passion for KNX innovation Iu m I my Q e e A S J Ou lt iil J7 00 we It ex EE il Lies DEZ H MAXinBOX SHUTTER SCH ZIO MBSHUS I gt gt oe um ie 2 il ul se zm o 4 o 4 e e ill ul ze O A ill eg 2 200011 NE tev E dc ONE MAXinBOX SHUTTER SCH 8 Channel Shutter Actuator ZIO MBSHU8 Application program version 1 0 User manual edition 1 0 _a www zennio com M t 2 zZ t oc LU Y gt Zennio MAXinBOX SHUTTER 8CH CONTENTS Gold aaa ici root poten PU 2 ND Pe mt 3 1 1 MAXinBOX SHUTTER SCH 3 eZ ASTANA IO EE 4 1 39 Start DANG Power e EE 5 MEE SS OI E 6 Ce D E E E TRI 6 EE 6 22 OS EE 7 22 rte 7 ETS e Ed Le eee ene ee ee nr ean eee ee ee ee 9 La LOC UMC deu E 11 2 4 Scene Temportsation esee nennen nennen nete sse sen tesa seea sess sese se se eun 12 DK uiii de M EEE mm 12 ANNEXL COMMUAICA NON OBJECTS assi 14 http www zennio com Technical Support http zennioenglish zendesk com 2 Zennio MAXinBOX SHUTTER 8CH 1 INTRODUCTION 1 1 MAXINBOX SHUTTER 8CH MAXinBOX SHUTTER 8CH from Zennio is a KNX specific actuator for controlling motorised shutter blind systems The most outstanding features are d 16 relay outputs configurable as up to 8 independent shutter channels with or without s
4. CTR DPT_Scaling 0 100 FL Function x Result 1 byte Percentage CTR DPT Value 2 Count 32768 32767 FL Function x Result 2 bytes Signed 671088 00 CTR DPT Value Temp 670760 00 FL Function x Result C W DPT SceneControl 0 63 128 191 Shutter Scenes C w DT Step Cx Stop Step 1 Bit l Byte 2 Bytes 76 95 4 Bytes l Byte 2 Bytes 2 Bytes 2 bytes Float O 63 Execute 1 64 128 191 Save 1 64 O Raise 1 Lower l Byte 97 114 131 148 165 182 199 216 98 115 132 149 1 Bit 1 Bit O Stop StepUp 1 Stop StepDown http www zennio com Technical Support http zennioenglish zendesk com 4 E Zennio MAXinBOX SHUTTER 8CH 167 184 201 218 168 185 202 219 169 186 203 220 170 187 204 221 171 188 205 222 172 189 206 223 173 190 207 224 106 123 140 157 174 191 208 225 107 124 141 158 175 19272095226 176 193 210 227 177 194 211 228 110 127 144 161 178 195 212 229 111 128 145 162 179 196 213 230 180 197 214 231 1681 1985 215 232 1 Bit 1 Bit 1 Bit 1 Byte 1 Byte 1 Byte 1 Byte 1 Bit 1 Bit 1 Bit 1 Bit 1 Bit 1 Bit 1 Bit 1 Bit 1 Bit 1 Bit DPT_ Trigger DPT Enable DPT Switch DPT Switch DPT_ Scaling DPT_Scaling DPT_ Scaling DPT_ Scaling DPT Alarm DPT Alarm DPT Alarm DPT Alarm DPT_ Trigger DPT UpDown DPT_ Trigger
5. SHUTTER 8CH Note due to the actions that may have been performed during the Test On mode the device will ignore the real status of the shutter when the user leaves such mode Therefore the Test On mode is useful to synchronise the device status and the actual status of the shutter The lock timer alarm and scene functions as well as any orders received from the KNX bus will not have an effect over the shutter status while the device is under the Test On mode The shutter status objects will not be sent to the bus either On the contrary the alarm and lock objects will be re evaluated after leaving the Test On mode so any changes that may have taken place in Test On will be considered when leaving Important the device is factory delivered with both manual modes Test Off and Test On enabled by default ETS PARAMETERISATION The manual control is configured from the Configuration tab under Manual Control The only two parameters are GENERAL Manual Control Test Off Mode Test On Mode 4 Manual Control j _ Configuration Manual Control Lock Wi Value o Unlock 1 Lock Initialization Last value Figure 3 Manual Control 2 Manual Control options are Disabled Only Test Mode Off Only Test Mode On and Both Test Mode Off and On default Depending on the selection the device will permit using the manual control under the Test Off the Test On or both modes Note that a
6. com Technical Support http zennioenglish zendesk com 13 Zennio MAXinBOX SHUTTER 8CH ANNEX I COMMUNICATION OBJECTS Functional range shows the values that with independence of any other values permitted by the bus according to the object size may be of any use or have a particular meaning because of the specifications or restrictions from both the KNX standard or the application program itself Function Data Type DPT Functional Range Name I O Number Size Flags 1 Bit Voltage Recovery gt Sending of O 1 Bit Voltage Recovery gt Sending of 1 1 Bit DPT_ Switch Lock Manual Control O Lock 1 Unlock 1 Bit DPT Switch Lock Manual Control O Unlock 1 Lock 4 35 1 Bit DPT Bool FL 1 bit Data Entry x Binary Data Entry 0 1 36 51 l Byte DPT Value 1 Ucount O 255 FL 1 byte Data Entry x 1 byte Data Entry 0 255 DPST 7 1 0 65535 52 67 2 Bytes C W DPST 8 1 32768 32767 FL 2 bytes Data Entry x 2 bytes Data Entry DPST 9 1 273 00 670760 00 68 75 4 Bytes 4 bytes Data Entry 2147483648 C W DPT Value 4 Count 2147483647 FL 4 bytes Dato de entrada x CTR DPT Bool FL Function x Result 1 bit Boolean CTR DPT Value 1 Ucount 0 255 FL Function x Result 1 byte Unsigned CTR DPT Value 2 Ucount 0 65535 FL Function x Result 2 bytes Unsigned 2147483648 l l CTR DPT_Value 4 Count 2147483647 FL Function x Result 4 bytes Signed
7. d On the contrary switching to the Test On mode unless disabled by parameter needs to be done by long pressing the Prog Test button for at least three seconds until the LED is no longer red and turns yellow From that moment once the button is released the LED light will remain green to confirm that the device has switched from the Test Off mode to the Test On mode After that an additional press will turn the LED yellow and then off once the button is released This way the device leaves the Test On mode Note that it will also leave this mode if a bus power failure takes place http www zennio com Technical Support http zennioenglish zendesk com T Zennio MAXinBOX SHUTTER 8CH Test Off Mode Under the Test Off Mode the shutter channels can be controlled through both their communication objects and the actual pushbuttons located on the top of the device When one of these buttons is pressed the shutter will behave as if an order had been received through the corresponding communication object and will also send the status objects when required This behaviour depends on the length of the button press d A long press makes the shutter start moving upwards or downwards depending on the button being pressed The LED will light in green until the end of the motion If the button gets pressed being the shutter already at the top or bottom positions nothing will happen the LED will not light d A short pre
8. ection 2 2 Please secure the connection by means of the on board screws d Manual control pushbuttons 6 pushbuttons for a direct control of the shutter channels during the set up process See section 2 2 1 http www zennio com Technical Support http zennioenglish zendesk com 4 Zennio MAXinBOX SHUTTER 8CH To get detailed information about the technical features of this device as well as on the installation process and on security procedures please refer to the corresponding Datasheet bundled with the original packaging of the device and also available at www zennio com 1 3 START UP AND POWER LOSS During the start up of the device the Test Prog LED will blink in blue colour for a few seconds before the device is ready External orders will not be executed during this time but afterwards Depending on the configuration some specific actions will also be performed during the start up For example the integrator can set whether the shutter channels should change to a particular position and whether the device should send certain objects to the bus after the power recovery Please consult the next sections of this document for further details On the other hand when a bus power failure takes place the device will interrupt any pending actions and will save its state so it can be recovered once the power supply is restored For safety reasons all shutter channels will be stopped i e the relays wil
9. l open if a power loss takes place http www zennio com Technical Support http zennioenglish zendesk com 9 Zennio MAXinBOX SHUTTER 8CH 2 CONFIGURATION 2 1 GENERAL After importing the corresponding database in ETS and adding the device into the topology of the desired project the configuration process begins by right clicking into the device and selecting Edit parameters ETS PARAMETERISATION The only parameterisable screen available by default is General From this screen it is possible to activate deactivate all the required functionality GENERAL Outputs El Manual Control Logic Functions E scene Temporization El Manual Control Ei sending of Indication Objects 0 and 1 on El bus voltage recovery Figure 2 General screen d Once activated Outputs Logic Functions and Manual Control bring additional tabs to the menu on the left These functions and their parameters will be explained in later sections of this document The Manual Control function is enabled by default and so is the corresponding configuration tab d Sending of Indication Objects 0 and 1 on Bus Voltage Recovery this parameter lets the integrator activate two new communication objects Reset 0 and Reset 1 which will be sent to the KNX bus with values 0 and 1 respectively whenever the device begins operation for example after a bus power failure It is possible to
10. lats 9 20 customisable multi operation logic functions d Scene triggered action control with an optional delay in the execution d Manual operation supervision of the 8 shutter channels through the on board pushbuttons and LEDs http www zennio com Technical Support http zennioenglish zendesk com 3 Zennio MAXinBOX SHUTTER 8CH 1 2 INSTALLATION MAXinBOX SHUTTER 8CH connects to the KNX bus through the on board KNX connector Once the device is provided with power from the KNX bus both the individual address and the associated application program may be downloaded This device does not need any additional external power since it is entirely powered through the KNX bus Upper Outputs Lower Outputs Prog Test LED KNX Bus Connector Prog Test Pushbutton 9 anne AS 29 Vs NOTES 3 Manual Control Pushbutton Output Status LED Por AN IT Figure 1 MAXinBOX SHUTTER 8CH The main elements of the device are described next d Test Prog Pushbutton 5 a short press on this button sets the device into the programming mode making the associated LED 3 light in red Note if this button is held while plugging the device into the KNX bus the device will enter into safe mode In such case the LED will blink in red every 0 5 seconds d Outputs 1 and 2 output ports for the insertion of the stripped cables of the systems being controlled by the actuator See s
11. of them entirely customisable and consisting in up to 4 consecutive operations each one The execution of each function can depend on a configurable condition which will be evaluated every time the function is triggered through specific parameterisable communication objects The result after executing the operations of the function can also be evaluated according to certain conditions and afterwards sent or not to the KNX bus which can be done every time the function is executed periodically or only when the result differs from the last one Please refer to the specific Logic Functions in MAXinBOX SHUTTER 8CH user manual available at the Zennio homepage www zennio com for detailed information about the functionality and the configuration of the related parameters http www zennio com Technical Support http zennioenglish zendesk com 11 Zennio MAXinBOX SHUTTER 8CH 2 4 SCENE TEMPORISATION he scene temporisation allows imposing delays over the scenes of the shutter channels These delays defined in parameters are applied on the execution of one or more scenes that may have been configured Please bear in mind that as multiple delayed scenes can be configured for each shutter channel in case of receiving an order to execute one of them when a previous temporisation is still pending in that channel the channel will interrupt such temporisation and will only execute the delay and the action of the new scene
12. parameterise a certain delay to this sending 0 to 255 seconds http www zennio com Technical Support http zennioenglish zendesk com 6 Zennio MAXinBOX SHUTTER 8CH 2 2 OUTPUTS MAXinBOX SHUTTER SCH incorporates 16 relay outputs configurable as up to 8 independent shutter channels each of which will operate one motorised shutter system For detailed information about the functionality and the configuration of the parameters related to the shutter channels please refer to the specific manual Shutter channels in MAXinBOX Shutter 8CH available at the Zennio homepage www zennio com 2 2 1 MANUAL CONTROL MAXinBOX SHUTTER 8CH allows commanding the shutter to move up or down through the pushbuttons on the top of the device Two specific pushbuttons are provided per channel i e one per relay output Manual operation can be done in two different ways named as Test On Mode for testing purposes during the configuration of the device and Test Off Mode for a normal use anytime Whether both only one or none of these modes are available needs to be parameterised in ETS Moreover it is possible to enable a specific binary object for locking and unlocking the manual control in runtime Note d The Test Off mode will be active unless it has been disabled by parameter after a download or a reset with no need of a specific activation the pushbuttons will respond to user presses from the start
13. s stated before using the Test Off mode does not require any special action while switching to the Test On mode does require long pressing the Prog Test button d Manual Control Lock unless the above parameter has been Disabled the Lock Manual Control parameter provides an optional procedure for locking http www zennio com Technical Support http zennioenglish zendesk com 9 Zennio MAXinBOX SHUTTER 8CH the manual control in runtime When this checkbox is enabled object Manual Control Lock turns visible as well as two more parameters gt Value defines whether the manual control lock unlock should take place respectively upon the reception through the aforementioned object of values 0 and 1 or the opposite gt Initialization sets how the manual control should remain after the device Start up after an ETS download or a bus power failure Unlocked Locked or Last Value default on the very first start up this will be unlocked http www zennio com Technical Support http zennioenglish zendesk com 10 Zennio MAXinBOX SHUTTER 8CH 2 3 LOGIC FUNCTIONS This module makes it possible to perform numeric and binary operations to incoming values received from the KNX bus and to send the results through other communication objects specifically enabled for this purpose MAXinBOX SHUTTER 8CH can implement up to 20 different and independent functions each
14. ss will make the shutter drive stop if in motion as it normally does when a step stop order is received from the KNX bus In case of not being the shutter in motion pressing the button does not cause any action unless slats lamellas have been parameterised in such case a step movement up down depending on the button pressed will take place Regarding the lock timer alarm and scene functions the device will behave under the Test Off mode as usual Button presses during this mode are entirely analogous to the reception of the corresponding orders from the KNX bus Test On Mode After entering the Test On mode it will only be possible to control the shutters through the on board pushbuttons Orders received through communication objects will be ignored Pressing the button will make the shutter drive move upward or downward depending on the button until the button is released again thus ignoring the position of the shutter and the parameterised times The LED will light in green while the button is being hold For safety reasons the device does not allow the activation of the two outputs of a shutter channel at the same time lf the button of one of the outputs is held while the other output is active the device will first deactivate it and afterwards perform the required action on the output associated to the button pressed http www zennio com Technical Support http zennioenglish zendesk com 8 Zennio MAXinBOX