Wind Sensor type WSS REC

image

Contents

1. when mounting the wind sensor the arrow printed on the bottom of the sensor must be parallel with the centre axis of the nacelle from rotor to the back On land based non rotating installations the arrow must point towards North DEIF A S 1 lt lt 1 1 1 1 Page 6 of 14 55 User s Manual Installation Note Bird avoidance kit optional The bird avoidance kit is designed to reduce the risk of birds landing on the WSS REC and thereby interfering with measurements or even damaging the sensitive ultrasonic transducer heads the black rubber heads may attract the attention of birds The kit is an optional extra and is installed on top of the sensor The spike system is designed not to hurt birds but simply create a barrier to make it difficult for birds to land on top of the sensor Please note that the kit does not provide complete protection against birds but especially large sea birds will not be able to land whereas small birds may still be able to squeeze in Small birds may interrupt the wind measurement but will not be able to damage the sensor The shape and location of the spikes is designed so the interference with wind measurements is negligible It is recommended to use the kit if there is a high accumulation of birds in the area where the sensor is used snow may be able to accumulate on top of the sensor When the kit is mounted on the WSS REC sensor more and it may melt slow
2. Wind Sensor type WSS REC Mounting e Connection Technical specifications References DEIF A S Frisenborgvej 55 DK 7800 Skive Tel 45 9614 9614 Fax 45 9614 9615 Document no 4189350037A info deif com gt www deif com 55 User s Manual Installation Note Table of contents 1 INTRODUCTION 3 UNPACKING Gan enda ten dd 4 LEGAL INFORMATION AND RESPONSIBILITY 4 2 MOUNTING THE WIND SENSOR 5 PLACING OF THE WIND SENSOR 5 BIRD AVOIDANCE KIT OPTIONAL 7 3 CABLE 0 5 8 THE WSS REC WIND SENSOR CABLE CONNECTIONS 8 CONNECTOR KIT ASSEMBLY OPTIONAL 9 4 2 eere 10 5 TECHNICAL SPECIFICATION 11 6 REFERENGES de inne eas 14 DEIF A S Page 2 of 14 55 User s Manual Installation Note 1 Introduction This document provides guidelines for mounting and connecting the WSS REC static wind sensor The ultrasonic wind measuring system used in the WSS REC is a
3. fast responding and accurate system designed for measurement of wind speed and wind direction The sensor is based on three ultrasonic transducers arranged in a triangle for measuring of wind speed and wind direction By measuring the time it takes for a set of ultrasound bursts to travel from each transducer to the other two the wind speed and direction can be calculated The WSS REC has a built in heater which will automatically engage when risk of icing occurs during low temperatures DEIF A S Page 3 of 14 55 User s Manual Installation Note Unpacking The WSS REC sensor is delivered in a cardboard box To protect the delicate sensor heads it is important to store it in the box until mounting Do not hit squeeze or try to remove the three black rubber hoods The sensor is protected against ESD static electricity but it is recommended to avoid static discharge through the connection wires during installation Legal information and responsibility DEIF takes no responsibility for installation or operation of the wind measuring system If there is any doubt about how to install or operate the WSS REC the company responsible for the installation or the operation of the product must be contacted The units are not to be opened by unauthorised personnel If opened anyway the warranty will be lost DEIF A S Page 4 of 14 55 User s Manual Installation Note 2 Mounting the wind senso
4. 2 6 and DNV Class A 3 15Hz 2 5mm peak GL curve 4 15 50Hz 2 39 for masts Safety Cat poll dg 2 550 AC rms 50Hz EN 61010 1 1 minute EMC CE marked for industrial environment EN 61000 1 1 2 3 4 Housing Wind sensor housing UL94 VO Polycarbonate 10 glass fibre Mounting tap Corrosion resistant stainless steel Weight 0 8kg Dimensions 450 x 315 x 230mm cardboard box DEIF A S Page 12 of 14 55 User s Manual Installation Note Sensors are designed according to the standards below Standards Accessories 66 connection box kit IP66 connection box with cable glands and screw terminals to extend the sensor cable with an extension cable 1 67 connector kit Watertight male and female connector for soldering to the sensor cable and the extension cable respectively Extension cable 1 to 300m shielded cable DEIF ID no 1020230016 Bird avoidance kit Spike kit to prevent birds from interrupting the wind measurements or in worst case from damaging the sensor DEIF A S Page 13 of 14 55 User s Manual Installation Note 6 References For more details please refer to the following documentation Appendix to User s Manual WSS REC document no 4189350038 Documentation is available at www deif com Download centre DEIF A S reserves the right to change any of the above DEIF A S Page 14 of 14
5. er Installation of the kit 1 Position the metal ring with spikes around the stainless steel top plate of the WSS REC sensor Position it so the spikes do not block the direct paths between the three black WS 7 rubber heads see picture 2 Secure the metal ring using the Ex M3x6 screw provided It j recommended to secure the screw Ah from loosening due to vibrations with a drop of Loctite super glue or equivalent not included in the kit and tighten the screw all the way in 3 Check that the kit is fitted tightly on the WSS REC DEIF A S Page 7 of 14 55 User s Manual Installation Note 3 Cable connections The wind sensor is supplied with 10 metres fixed cable From factory the cable is connected to the sensor via a waterproof gland and this must not be replaced by another cable The cable can be extended by using the connection box kit or the IP67 connector kit both optional In order to protect the wind sensor and the personnel in the best possible way from lightning strokes use a lightning rod installed with the tip at least one metre above the wind sensor The lightning rod must be properly grounded in compliance with all applicable safety regulations The wind sensor cable screen and the extension cable Screen must be connected For further protection of the cable from the wind sensor it is recommended to use a metal conduit pipe cable Suitable extension cable is availab
6. etention 184 73 without internal cable retention 25 TU Solder contacts with internal cable retention 144 44 without internal cable retention 22 44 Crimp contacts 0 14 0 50 mm 245 clamping ring with mounted gasket 050 15 mm 354 tack shel Y ith internal cable retenti 144 igiteni 1 1 PE 2mm 2 end splice recommended 3 lt strain rt ABS gt Al 24 V ES 16 ode male contact AN Y j included gasket meen insert with i 9 oe g cable nut tightening torque 15 2 tightening torque 0 5 L Hf gt lt female contact insert with locking ring DEIF A S Page 9 of 14 55 User s Manual Installation Note 4 Dimensions g 34 pipe thread Outer diameter tg 1 04inch 26 4mm 14 threads per inch 272 a ae 7 Uf Ff KF 2 gt A DEIF A S Page 10 of 14 55 User s Manual Installation Note 5 Technical specification Sensors are designed according to the standards below Standards Power supply 12 24V 9 0 31 2V DC Power consumption WSS REC with inactive heating element 0 1W WSS REC with maximum heating lt 15W Interface RS485 bus The bus should be terminated with 120 to 200 ohm for pure RS485 operation RS422 bus For s
7. ingle listener connection on RS422 the data line must be terminated with a 200 to 250 ohm resistor to obtain the necessary output Data sentence WIMWV Wind speed and direction data WIXDR Transducer measurement response WITXT Error messaging For details see doc no 4189350038 Appendix to User s Manual WSS REC NMEA 0183 ver 3 0 Wind speed Range 0 60m s Resolution 0 1m s Accuracy 0 35m s 0 3m s or 3 whichever is greater 236m s 5 Wind direction Range 0 360 continuously Resolution 1 Accuracy 3 in relation to wind direction Update interval 1 sec Start up time lt 5 sec from power on to valid data output DEIF A S Page 11 of 14 55 User s Manual Installation Note Sensors are designed according to the standards Standards below Connection 10 metres 4 x 0 75mm screened cable type UL2464 18AWG AC DW AL MY Jacket The 10m cable is fixed on the sensor and is open ended Mounting pipe thread Outer diameter 1 04inch 26 4mm 14 threads per inch Protection IP66 IEC 529 and EN 60529 Relative 0 100 humidity 60068 1 2 Pressure 600 1100hPa Temperature WSS REC operating range EN 60051 52 60 C class approved for 25 60 C Storage both 60 70 C Vibration test 3 13 2Hz 2mm peak peak EN 60945 13 2 100 2 0 7g EN IEC600 68
8. le from DEIF at any length between one and 300 metres Alternatively an installation cable e g UL2464 18AWGAC AE 4 x 0 75 screened be used The max length is 300m and maximum 70nF capacity between the signal conductors The WSS REC wind sensor cable connections Cable Function Note colour Black Supply 9 31V DC supply for the WSS Red voltage REC wind sensor Orange RS485 A Wind speed and direction data Brown comm B output Shield Cable shield Is connected to the stainless steel tap inside the WSS REC No supply voltage must be present during installation of the wind sensor as this will damage the wind sensor DEIF A S Page 8 of 14 55 User s Manual Installation Note Connector kit assembly optional The connectors must be soldered onto the cable according to the following instructions WSS fixed Connector WSS extension Signal cable pin no cable comments Male Female connector connector Plug male 7 pin 1 Plug female 7 pin 10 22 00 00 52 10 22 00 00 53 Screw cap male Screw cap female 10 29 92 00 02 10 29 92 00 03 Black 1 e 30V DC supply Red e 2 Red e for WSS Orange 3 RS485 comm Brown 4 Brown e from WSS REC Screen 5 Screen e Cable screen Mounting Instruction straight cable connector Screw contacts with internal cable r
9. r Placing of the wind sensor Ideally the wind sensor should be placed far from large objects that might influence the measuring results however in practice this is normally not possible on a wind turbine The best result is achieved by placing the wind sensor at the top of a mast in the opposite end of the rotor Placing the sensor just above the nacelle and just behind the rotor is disadvantageous This may result in turbulence velocities and wind directions that are out of proportion to the actual undisturbed wind speed and wind direction The wind sensor is intended for installation on a vertical socket or a tube using the stainless steel tap mounting base See the drawing on the next page for dimensions of the tap The tap must not be removed from the wind sensor as this will damage the waterproof sealing and the warranty will become void Do not expose the plastic part of the wind sensor to any torque when mounting the sensor The tools used for fastening are only to be applied on the actual tap DEIF A S Page 5 of 14 55 User s Manual Installation Note IMPORTANT The stainless steel mounting base on the WSS sensor must be connected to earth e g the steel hull pipe thread Outer diameter 1 04inch 26 4mm 14 threads per inch To ensure that the measurement represents the precise wind direction relative to the turbine the wind sensor must be aligned correctly