RIGOL User`s Guide DP1116A Programmable DC Power Supply
Contents
1. NOTE DHCP parameters such as IP address Sub Mask and Default Gateway are allocated from the DHCP sever of the current network Auto IP an IP address within 169 254 0 1 and 169 254 255 254 and Sub Mask 255 255 0 0 are obtained automatically according to the current network setting Manual IP parameters such as IP address Sub Mask Default Gateway and DNS server are defined by users as desired using the up and down direction keys When the DHCP Auto IP and Manual IP are all selected the priority level is DHCP Auto IP and Manual IP The three settings cannot be all Off at least one should be On Besides see figure below you can press I O and go to the second page and press Default OK to restore the LAN into the factory defaults LAN Status DHCP IP Addr 172 16 3 30 eege Auto IP Subnet 255 255 255 0 IP Configure Mode Manual IP Gateway 172 16 3 1 DNS be Sal BAe Kee LX MAC 00 1A 9F 12 36 78 VISA TCPIPO 172 16 3 30 INSTR m Default Figure 2 19 LAN defaults 2 USB Press I O USB and enter the following interface from where you can see the VISA address of the USB Device port on the rear panel user defined is unnecessary User s Guide for DP1116A 2 25 RIGOL Chapter 2 Front Panel Reference USBO 0x1AB1 0x0E10 DP1A666666666 INSTR USB GPIB Figure 2 20 USB ID information 3 GPIB Press I O GPIB and enter the interface shown below
2. 10 ms OCP Mechanical Dimension 235 mm W x 155 mm H x 384 mm D Weight 11 kg Power Supply AC input 100 Vac 10 115 Vac 10 50 Hz 60 Hz 220 Vac 10 230 Vac 10 up to 250 Vac Environment Full rating output 0 C 40 C Working Temperature At high temperature the output current drops to 50 at 55 Cof maximum Cooling Fan cooling Product Regulation CE cTUVus Remarks 1 Specifications are for one hour warm up and at 25 C 2 The maximum time required for regulating the corresponding output when received APPLy 5 2 User s Guide for DP1116A Chapter 3 Remote Control RIGOL and SOURce commands 3 The varieties of outputs within 8 hours when the instrument has been warmed up for 30 minutes and both the load circuit and environment temperatures are in constant conditions User s Guide for DP1116A 5 3 Chapter 6 Appendix RIGOL Chapter6 Appendix Appendix A Accessories A power cord that fits the standard of destination country A USB data cable A CD including Users Guide An Instruction 4 fuses 250 V T2 5 A and 250 V T4 A 2 for each 2 shorted devices Note All the accessories can be ordered from your local RIGOL office User s Guide for DP1116A 6 1 RIGOL Chapter 6 Appendix Appendix B Warranty RIGOL warrants that its mainframe and accessories of the product will be free from defects in materials and workmanship within the warranty per
3. P Wel Network Ne RIGOLWeb Products Service amp Support e ge ee FR B L IP Settings IP Mode DHCP Host Name Domain Name IP Mode Setting Z DHCP Ei Manual IP S Auto IP IP Address 172 Lg D I 38 Subnet Mask 255 255 255 o Default Gateway 172 Line LUS Ln DNS Server 172 Lg Ll2 Is Description Apply LAN Configuration Initialize Figure 3 4 Network setting interface In this interface you can set desired IP parameters and then click Apply to apply the new setting or click Cancel to cancel the setting To restore the factory defaults click LAN Configuration Initialize Note If a password is necessary for the entrance of the web click Network Settings and to enter the following dialog here you should enter the correct user name and password the default user name and password are empty To create a new password or modify the password that has already existed please refer to 4 3 Click Help and enter the help interface for the information about the instrument and network see figure below User s Guide for DP1116A 3 3 RIGOL Chapter 3 Remote Control E L EK a Network RIGOL Web Products Service amp Support won Bar Ege Es Hep zou Help About All pages of This Instrument Instrument Introduction DP1116A is a programmable linear DC power supply with low ripples and noise and has triple output controlled
4. a 1 2 A O V P set 0 000 V S S S O C P Figure 1 3 User interface of DP1116A Explanations Explanations Active channel Help system identifier Channel status Beeper identifier Actual output Voltage current input box LAN connection identifier O V P status setting box Keylock O V P input box Self test failed O C P status setting box O T P identifier O C P input box Remote control identifier 8 6 6 8 e 9 e e 2 Operation menu SIS OIS Sn IG Z USB device identifier Remark This area displays the actual output values of voltage current and power as well as the identifier of Sense CC constant current or CV constant voltage NOTE The DP1116A has three display modes and each mode has its own interface for more details please refer to Display Mode User s Guide for DP1116A RIGOL Chapter 1 Quick Start First Use of DP1116A Prior to making any connections to the instrument read the section of General Inspection carefully to avoid any possible or potential dangers and carry out necessary check and inspections following the requirements below when you first use the DP1116A Power Requirements Use the power cord that is specifically designed for the DP1116A to connect the instrument and the AC power which delivers 100 V 115 V 220 V or 230 V 50 Hz to 60 Hz Users should select a volt
5. No Name Explanations Connect as a main unit with an external USB device such as USB flash devices LU USB Host 1 4 User s Guide for DP1116A Chapter 1 Quick Start Sense terminal RIGOL Compensate the voltage drop Power output Ee Output the power supply This terminal is connected with the chassis and ground Earth terminal wire grounded through the power cord and can be User s Guide for DP1116A used as an additional ground terminal for other devices when the instrument is power on 1 5 RIGOL Rear Panel Chapter 1 Quick Start LXI Class C Non Auto MDIX 100v CJ Fuse T4A 50 60Hz ug C 220v CO AC 250V Tan S00VA Ze C Figure 1 2 Rear panel overview No Name Explanations GPIB port Conform to the IEEE 488 2 protocol Fan Air outlet Supply hub AC power inlet ER Power voltage Select a proper scale according to the input selector voltage manually LAN port Access to LAN through a RJ45 interface USB device port Connect as a slave device with an external USB device Fuse Provided with two types of specifications 250 V T4 A and 250 V T2 5 A Power switch Power on or cut off the power supply User s Guide for DP1116A Chapter 1 Quick Start User Interface RIGOL 000 0 00 sev 10 000 V 104 Curr 00 000 KR W 37 ov 000 00 Wo 0 C P
6. Output Inspection Display Mode User s Guide for DP1116A 1 1 RIGOL Chapter 1 Quick Start General Inspection Please inspect your new DP1116A according to the following steps 1 2 Inspect the shipping container for damage Keep the damaged shipping container or cushioning material until the contents of the shipment have been checked for completeness and the instrument has passed both electrical and mechanical tests The consigner or carrier shall be liable for the damage to instrument resulting from shipment RIGOL would not be responsible for free maintenance rework or replacement of the unit Inspect the instrument In case of any damage or defect or failure notify your RIGOL Sales Representative Check the accessories The accessories supplied with the instrument are listed in Appendix A Accessories If your contents are incomplete or damaged please notify your RIGOL Sales Representative User s Guide for DP1116A Chapter 1 Quick Start RIGOL Front Rear Panel and User Interface Front Panel SS eS eS E Figure 1 1 Front panel overview No Name Explanations LU LCD Display the user interface Parameter input Include the numeric keys unit keys direction keys 2 area and enter key Power button Turn on or off the instrument o USB Host port Connect with an external USB device as the host device Menu key With different functions in d
7. Support USB flash device storage Support remote control via Web Support remote control via SCPI commands Conform to LXI C class instrument standards version 1 2 Support the built in help Support panel lock Support Chinese amp English interfaces and input User s Guide for DP1116A RIGOL Structure of this Document Chapter 1 Quick Start This chapter introduces you the panels and display interface as well as some considerations on first use of DP1116A Chapter 2 Front Panel Reference This chapter gives the detailed information on function and operating methods of each key on the front panel Chapter 3 Remote Control This chapter guide you how to control the DP1116A through the remote interfaces Chapter 4 Troubleshooting This chapter offers some methods to help you solve the possible problems during operations Chapter 5 Specifications This chapter lists the specifications of DP1116A Chapter 6 Appendix Information about accessories services and supports and the like Hint For the newest version of this manual please download from this URL http www rigol com The representations of panel keys and menu softkeys of the instrument in this book are Panel key key characters text box such as L6V 10A denotes the selection key of 16V 10A scale Menu softkey menu characters shading for example Volt denotes the voltage option under the channel setting menu User s G
8. Turn on the instrument press to start the instrument 3 Scale selection press L6V 10A at the front panel characters below this key are highlighted 4 Voltage setting press Volt and set the voltage to 16 V set 16 000 V Figure 2 5 Voltage setting 5 Current setting press Curr and set the current to 10 A 2 6 User s Guide for DP1116A Chapter 2 Front Panel Reference RIGOL set 16 000 V 0V OFF O C P 5 0 A mA Cancel Figure 2 6 Current setting 6 Turn on the output press On Off the letter below this key On is highlighted and the instrument will work under CV mode NOTE In CV mode if the output current exceeds the specified value because of the change of the load connected to the instrument will switch into CC mode according to the present current value and reduce the output voltage proportionally You can increase the setting value of the current at this moment in order to resume the CV output User s Guide for DP1116A 2 7 RIGOL Chapter 2 Front Panel Reference Constant Current Output For example Select the L6V 10A scale and separately set the voltage and current to 16 V and 10 A then connect a load with 1 5 Q 300 W to the instrument As 1 5 Q x 10 A 15 V lt 16 V and 16V 1 5 Q 10 7 A gt 10 A so the channel output power with constant current from this scale 15 V 10 A Operation Steps 1 Connect the output leads s
9. different graduations 16V 10A V ranges from 0 to 16 A ranges from 0 to 10 32V 5A V ranges from 0 to 32 A ranges from 0 to 5 In any scale W ranges from 0 to 160 Needle The numbers pointed by needle in the figure above are the current setting values Red Green line See Figure 1 7 values at the connections of the red and green lines in V and A dials are setting values of O V P and O C P respectively Turning on the O V P or O C P function will protect the circuit when the actual voltage or current reaches its setting value and the red and green lines in the dials will be highlighted at the same time User s Guide for DP1116A Chapter 2 Front Panel Reference RIGOL Chapter 2 Front Panel Reference This chapter describes in detail the function keys at the front panel and associated pull down menus Subjects in this chapter B Parameter Input R Constant Voltage Output RB Constant Current Output B Overvoltage Overcurrent Protection B Timing Output m Remote Voltage Sensing R Store and Recall R Utility Settings I O Settings System Settings Calibrate Timer Setting R Built in Help H Key Lock User s Guide for DP1116A 2 1 RIGOL Chapter 2 Front Panel Reference Parameter Input The DP1116A contains two methods of parameter input Pop up box input and Direct input modify All parameters have to be entered by using the numeric keys or unit direction keys see figu
10. done for your DP1116A please contact RIGOL technical support 2 32 User s Guide for DP1116A Chapter 2 Front Panel Reference RIGOL Timer Setting Before enabling the timer you have to set the parameters about it including voltage current and output time Both the two scales allow up to 100 groups of timing parameters From the figure below we can see that the timer setting interface is divided into two parts the waveform display area left and the parameter setting area right Waveform display area Parameter setting area ea 2 No Vol Curr A Set s Left s 0 10 00001 000 1 03 00005 000 D 3 00 00000 000 4 00 00000 000 gt SelPage Circle Figure 2 30 Timer setting interface The right area allows you to specify the voltage Volt current Curr and output time Set for each group and the left area shows the related waveform according to the settings in right area for users to directly view the output status Table 2 5 Timer parameter setting explanations Menu Explanation JL Go to the next setting page TT Go to the previous setting page SelPage Go to the desired setting page The total page is 20 Circle Set the circle parameters gt Go to the next menu page User s Guide for DP1116A 2 33 RIGOL Chapter 2 Front Panel Reference om Go to the previous menu page Save Store the specified timing parameters into the nonvolatile memory Exit Exit th
11. gt Calibrate TimerSet Exit Figure 2 17 System setting interface Table 2 3 The System setting interface explanations Menu Explanation 1 0 Set or reset the LAN parameter view the ID number of the USB device set the GPIB address Set the parameters about the system including Language Da Power on value Screen brightness Overtemperature Beeper Self test and view the system information Calibrate Enter the calibration interface TimerSet Set the timing output parameters about the channel Exit Exit the Utility function User s Guide for DP1116A RIGOL Chapter 2 Front Panel Reference I O Settings The DP1116A provides three communications interfaces LAN USB and GPIB You can set them upon the I O menu 1 LAN Press I O LAN and enter the setting interface shown below LAN Status DHCP IP Addr 172 16 3 30 Configered Auto IP Subnet 255 255 255 0 IP Configure Mode Manual IP Gateway 172 16 3 1 DHCP DNS nie L Ee ZE LX MAC 00 1A 9F 12 36 78 VISA TCPIPO 172 16 3 30 INSTR Figure 2 18 LAN setting Set the IP address Choose the IP setting mode from DHCP Auto IP and Manual IP by using the up and down direction keys then press OK to select with v shown in the related white box or cancel with empty in the related white box the related IP setting mode 2 24 User s Guide for DP1116A Chapter 2 Front Panel Reference RIGOL
12. open the remote control panel and send commands or read the data see figure below Device Clear SystemError Options d Read STB Change File Clear History About to USBO O0x1AB1 Ox0E10 DP1A666 DP11164 DP1A6666 00 01 00 00 01 00 00 01 00 00 Figure 3 9 Read and write commands through USB User s Guide for DP1116A 3 7 RIGOL Chapter 3 Remote Control 2 1 2 3 4 5 3 8 By LAN Please follow the steps below Connect the instruments Use a Net cable to connect your DP1116A to LAN Configure the network parameter Select LAN referring to the I O Settings in Chapter 2 Search the available device Open the Ultra Sigma and click to search the devices connected to LAN The status bar of the software during the search is CG Search LAN instrument Figure 3 10 Status bar of LAN searching View the available devices As shown in figure below devices that have been detected will be listed under the RIGOL Online Resource LAN GPIB USB TMC RS232 IVI Config Verify All RIGOL Online Resource B DP1116A IAM E DI C Other 0 DP1116A DP1A66 00 01 00 00 01 00 00 01 00 00 Figure 3 11 Available LAN resources Communication test Right click DP1116A TCPIP 172 16 3 38 INSTR and select Instrument Common_RIGOL_SCPI ControlPanel_V1 to open the remote control panel and send commands or read the data see figure below U
13. the instrument can make a proper response to every front panel operation and output the relevant ratings The inspections are mainly centered on the voltage output on the occasion of no loads and the short circuit current output from each scale 2 1 2 Channel selection and output switch See figure below the front panel has two scale keys 16V 10A and32V 5A and a switch key On Off 16V 32v On 10A 5A Off 16V 32V 10A 5A on Figure 1 4 Scale keys and switch key The instrument allows a scale output at the same time If you press 16V 10A or B2V 5A the characters below the pressed key will be highlighted and the screen will automatically switch into the corresponding setting interface To turn on the output of the selected scale press On Off and the character On below this key will also be highlighted to turn off the output repress this key Voltage output inspection Press and make sure that the Current setting value of each scale is none zero when the instrument is under no load running Inspect the voltage function of the 16V 10A scale Press 16V 10A On Off and you will see a character CV shown on the screen which indicates the channel you opened is in Constant Voltage output mode Then check if the voltage in this scale can be set from 0 to 16 8 V maximum rating For how to enter the parameter please refer to Parame
14. 000 A Figure 2 25 Beeper setting User s Guide for DP1116A 2 29 RIGOL Chapter 2 Front Panel Reference 6 SelfTest Press Selffest and enter the setting interface See figure below users can execute a self test and view the related results 00 000 A 000 00 Es Test Result Figure 2 26 Self test menu If you press Result before any self test the results shown under this menu are from the Power on self test see figure below Self Test Result 1 FAN Pass 7 Out Error 2 USB Pass 8 0P No Run 3 LAN Pass 4 FPGA Pass 5 ADC Pass 6 DAC Pass Figure 2 27 Self test results 2 30 User s Guide for DP1116A Chapter 2 Front Panel Reference RIGOL 7 SysInfo From this menu you can view the related system information see figure below System Information Model DP1116A Serial Number DP1A666666666 Hardware Version 00 01 00 Logic Version 00 01 00 SoftWare Version 00 01 00 00 Figure 2 28 System information interface User s Guide for DP1116A 2 31 RIGOL Chapter 2 Front Panel Reference Calibrate Press Calibrate and enter the correct password in the pop up box as shown in figure below a G Se 093 000 V nA Ann V 1 6V Please input password OAI 000 00 ES OGP 1 2A OK Cancel 10A Figure 2 29 Calibration password entry interface NOTE The instrument has been calibrated before leaving factory We suggest users not to do a personal calibration If the calibration must be
15. 60W power and two scales output The excellent performance provided by this unit ensures a more pure and stable output from itself Besides the friendly clear user interface and a variety of configuration interfaces as well as plenty of standard interfaces bring you more conveniences in actual use Main Features 4 3 inch 16 M true color TFT LCD Single voltage current output in two scales 16 V 10 A or 32 V 5 A Low ripples noise lt 350 uVrms 3 mVpp Excellent line regulation rate lt 0 01 2 mV voltage lt 0 01 250 pA current Excellent load regulation rate lt 0 01 2 mV voltage lt 0 005 250 pA current Overvoltage Overcurrent protection functions which can effectively guarantee the load connected to the instrument by specifying proper overvoltage and or overcurrent parameters Two level overtemperature protection function Store and recall system setups Timing output function which can support up to 100 groups of timing settings and infinite or specified number of cycles output Waveform display function which can display the output voltage current and power waveforms in real time so that the output status of the instrument become clear for users in co operation with the digital parameters shown near the waveforms Classic display mode dial plates classical pointer clear variation tendency of the voltage current and power Standard interfaces USB Device USB Host LAN and GPIB IEEE 488
16. 6A 2 11 RIGOL Chapter 2 Front Panel Reference O C P The O C P contains Parameter and ON OFF setting Please proceed as follows 1 Parameter setting Press 16V 10A or B2V 5A to select an output scale Press O C P Enter a value within 0 1 A and 11 A using the numeric keys and select A or mA as its unit Observe the variety in the O C P input box 2 Enable Disable the O C P Press L6V 10A or 82V 5A to select an output scale Press On Off to enable the output of the scale you select Press O C P Press O C P continuously to switch the state of the O C P between ON and OFF Please note the variety in the O C P input box as shown in figure below e 9 set 16 000 V vey 16 000 V GE ovp H 00 000 A 27 0V 10A O C P status W s IT OC value Curr O V P OCP Figure 2 8 O C P setting 2 12 User s Guide for DP1116A Chapter 2 Front Panel Reference RIGOL NOTE When the channel output is OFF the O C P function is also disabled but you can set its parameter The output will be automatically disabled if the output current exceeds the O C P value The defaults of the O C P status and value are OFF and 11A respectively User s Guide for DP1116A 2 13 RIGOL Chapter 2 Front Panel Reference Timing Output The DP1116A has Timing Output function When you enable the timer the instrument will output the pre speci
17. GPIB0 25 INSTR and select Instrument_Common RIGOL_SCPI ControlPanel_V1 to enter the remote control panel and send commands or read the data see figure below i DP1116A GPIBO 25 INSIR 2009 12 7 15 45 49 197 Device Clear SystemError 3 Options d Read STB Change File Tess History About o GPIBO 25 INSTR 6 00 01 00 00 01 00 00 01 00 00 Figure 3 16 Read and write commands by GPIB User s Guide for DP1116A 3 11 Chapter 4 Troubleshooting RIGOL Chapter 4 Troubleshooting 1 1 2 3 4 2 1 2 3 1 2 3 4 1 2 3 4 The screen still dark no display after power on Check the power connection Check if the power indicator is lighting and flickering Disconnect the power cord and check if the Voltage Selector is in proper scale and a right fuse is used and in good condition If the error still exists please contact RIGOL for help Constant voltage output is abnormal Check if the maximum power from the selected scale can meet the load requirement If meets please Check if the cable that used for connecting the load with the instrument is in good condition or has a short circuit Check if the load goes wrong Check if a proper current in this scale is specified if the value is too low increase it properly If the error still exists please contact RIGOL for help Constant current output is abnormal Check if the ma
18. Guide for DP1116A 3 5 RIGOL Chapter 3 Remote Control 1 2 3 4 By USB Please follow the steps below Connect the instruments Use a USB data cable to connect the USB Device port of your DP1116A to the USB Host of a PC Install the USB driver DP1116A is a USBTMC unit After you connect it with the PC correctly turn on the instrument the instrument will automatically use the USB interface a dialog appears on the PC screen and guide you to install the USB Test and Measurement Device driver Search the available device Open the Ultra Sigma the software will automatically search the instruments that connected to the PC through the USB port You can also search the device USB TMC through clicking The status bar of the software during the search is Figure 3 7 Status bar of USB seraching View the available devices Devices that have been detected will be listed under the RIGOL Online Resource in connection with their own model USB information See figure below User s Guide for DP1116A Chapter 3 Remote Control RIGOL LAN GPIB USB TMC RS232 IVI Config Verify All B RIGOL Online R E DP1116a8 D IVI Class Dr Other Onli IDN Rizo e DP BA DP1AG6 00 01 00 00 01 00 00 01 00 00 Figure 3 8 Available USB devices 5 Communication test Right click DP1116A USBO 0x1AB1 0x0E10 DP1A666666666 INSTR and select Instrument_Common_RIGOL_SCPI ControlPanel_V1 to
19. IP address in the internet browser to enter an interface as shown in figure below then click Web Identification Indicator and a message Target identified will be shown on the screen of the instrument To exit the message click this item again User s Guide for DP1116A 3 1 RIGOL Chapter 3 Remote Control Beyond Measure NY K a o AT R Fal Welcome Network A RIGOL Web Products Service amp Support Di Ko Situs ECH Die geg Se LXI Welcome to Web of DP1116A Digital Power Supply DP1116A Rigol Technologies f DP1A666666666 DP1116A C 1 2 00 1A4 9F 1 2 36 78 172 16 3 38 00 01 00 00 01 00 00 01 00 00 TCPIPO 172 16 3 38 INSTR NO G Web Identification Indicator H Figure 3 2 Welcome interface 1 Click Network Status and enter the network status interface as shown in figure below From this interface you can view the settings of TCP IP and network hardware RIGOL Beyond Measure KTN Network me Bs RIGOL Web Products Service amp Support Network Web Ge RM B D Network Status Information 172 16 3 38 255 255 255 0 17216 31 17216 22 mer 17216 23 Not Specified Automatic 100 Mbps Full Automatic Figure 3 3 Network status interface 2 Click Network Settings and enter the IP setting interface see figure below 3 2 User s Guide for DP1116A Chapter 3 Remote Control RIGOL
20. Network RIGOL Web Products Service amp Support ms Bs Ge B Be B X Security For All Changes of Configuration Old Password New Password l Confirm Password Figure 3 6 Network security setting interface 5 Click LXI icon and directly enter the official website of the LXI union http www xistandard org 3 4 User s Guide for DP1116A Chapter 3 Remote Control RIGOL Command Control The DP1116A Programmable DC Power Supply provides two ways for command control User defined Programming Users can control the DP1116A according to SCPI Standard Commands for Programmable Instruments For more details about the programming please refer to the Programming Guide of this product Using PC software from RIGOL or other manufactories Beside the software Ultra Sigma provided by RIGOL you can also use the Measurement amp Automation Explorer from NI National Instruments Corporation company or the Agilent IO Libraries Suite from Agilent Agilent Technologies Inc to control your DP1116A via remote interfaces by sending commands The DP1116A supports communications with a PC through USB LAN or GPIB bus In the following part we will introduce you how to use the associated Ultra Sigma software to control the DP1116A through various interfaces To get the Ultra Sigma software and the detailed operations please contact RIGOL technical support or your local sales office User s
21. RIGOL User s Guide DP1116A Programmable DC Power Supply Mar 2010 RIGOL Technologies Inc RIGOL Guaranty and Declaration Copyright 2010 RIGOL Technologies Inc All Rights Reserved Trademark Information RIGOL is a registered trademark of RIGOL Technologies Inc Notices RIGOL products are protected by patent law in and outside of P R C RIGOL Technologies Inc reserves the right to modify or change parts of or all the specifications and pricing policies at company s sole decision Information in this publication replaces all previously corresponding material RIGOL shall not be liable for losses caused by either incidental or consequential in connection with the furnishing use or performance of this manual as well as any information contained Any part of this document is forbidden to copy or photocopy or rearrange without prior written approval of RIGOL Product Certification RIGOL guarantees this product conforms to the national and industrial standards in China International standard conformance certification is in progress e g ISO Contact Us If you have any problem or requirement when using our products please contact RIGOL Technologies Inc or your local distributors or visit www rigol com User s Guide for DPII16A T Safety Notices General Considerations Please review the following safety precautions carefully before putting your instrument into operation so as to avoid
22. The GPIB address ranges from 1 to 30 You can enter a desired value using the numeric keys and press OK to save To delete the entered digits press lt GPIB Address 25 Figure 2 21 GPIB address setting 2 26 User s Guide for DP1116A Chapter 2 Front Panel Reference System Settings Press and enter the following menu Language PowerOn lt 1 1 Language Beeper Bright SelfTest O T P Syslnfo Figure 2 22 System setting menu Gs Cancel RIGOL Press Language and select a system language from the lower menu options F Xx Chinese and 2 PowerOn English Press PowerOn and enter its setting menu If you select Default the system will use the factory defaults when restart see table below If you select Last the system will use the settings before a power circle Table 2 4 Factory defaults explanations User s Guide for DP1116A Item Defaults Item Defaults DHCP ON Scale 3B2V 5A LXI function Auto IP ON Manual IP OFF Voltage OV GPIB address 25 Voltage 0 Current 5A Mimer Dins 0 Prams CircleNum 1 O V P value 35 2 V Language Last setting O C P value 11A PowerOn Default Channel LCD output ore brightness g O V P function OFF OTP OFF O C P function OFF Beeper ON GE OFF Web account Empty 2 27 RIGOL Chapter 2 Front Panel Reference function Web Display mode Genera
23. age scale that meets the standards in their own country through the Power voltage selector see Figure 1 2 at the rear panel and use an appropriate fuse Note 250 V T4 A fuse 100 V and 115 V 250 V T2 5 A fuse 220 V and 230 V To change the voltage scale of the instrument please 1 Turn off the power switch button at the front rear panel and remove the power cord 2 Check if the fuse installed before leaving factory 250 V T2 5 A can match with the selected voltage scale if not change it 3 Regulate the voltage selector to a desired scale using a straight screwdriver 1 8 User s Guide for DP1116A Chapter 1 Quick Start RIGOL Power On Check Connect your instrument to the AC supply using the supplied power cord and execute the power on inspection according to the following steps 1 Turn on the power switch at the rear panel N WARNING To avoid electric shock make sure the instrument has been properly grounded 2 Press down the power button Press down the power button at the front panel the instrument starts and executes the self test and then enter the user interface if the test is successful or else display a message like System selftest is wrong do you check the error on the interface For more details about this test press OK or press Cancel to exit the message User s Guide for DP1116A 1 9 RIGOL Chapter 1 Quick Start Output Inspection This function was designed for ensuring that
24. any personal injuries or damages to the instrument and any product connected to it To prevent potential hazards please use the instrument in compliance with regulations of this manual Use Proper Power Cord Only the power cord designed for the instrument and authorized by local country could be used Ground the Instrument The instrument is grounded through the Protective Earth lead of the power cord To avoid electric shock it is essential to connect the earth terminal of the power cord to the Protective Earth terminal before any inputs or outputs Connect Test Leads Correctly The test leads must be connected in strict accordance with regulations in this guide Observe all Terminal Ratings To avoid fire or shock hazard observe all ratings and markers on the instrument and check your manual for more information about ratings before connecting Use Proper Overvoltage Protection Make sure that no overvoltage such as those caused by a thunderstorm can reach the product or else the operator might expose to danger of electrical shock Do Not Operate Without Covers Do not operate the instrument with covers or panels removed Use Proper Fuse Please use the specified fuses Avoid Circuit or Wire Exposure II User s Guide for DP1116A RIGOL Do not touch exposed junctions and components when the unit is powered Do Not Operate With Suspected Failures If you suspect damage occurs to the instrument have it inspected by qualifie
25. ce NOTE Pressing lt will firstly delete the contents in the Chinese character display box and then the letter before the cursor in the File name entry field in the process of editing The file name should be within 6 Chinese characters or 12 letters words within numbers long 3 File recall Select a file path take local storage for example Press Browser move the cursor to the file window and select an effective setting file by using the up and down direction keys Press Recall to recall this file the screen will pop up a message like File load successful after the successful load Remark The effective setting file denotes the file with parameters saved hereinafter inclusive 4 File delete Select a file path take local storage for example Press Browser move the cursor to the file window and select an effective setting file by using the up and down direction keys Press Delete and Sure to delete this file 5 Update The DP1116A supports for the system update through a USB device After you select a desired file from the USB device press this key to start the system update 2 22 User s Guide for DP1116A Chapter 2 Front Panel Reference Utility Settings RIGOL Press Utility the backlight of this key goes on and the instrument enters the associated system setting interface see figure below set 03 000 V rey 03 000 V TIN 00 000 Am zov 000 00 Es en
26. d service personnel before further operations Any maintenance adjustment or replacement especially to circuits or accessories must be performed by RIGOL authorized personnel Keep Well Ventilated Inadequate ventilation may cause an increase of temperature or damage to the device So please keep well ventilated and inspect the intake and fan regularly Do Not Operate in Wet Conditions In order to avoid short circuiting to the interior of the device or electric shock please do not operate in a humid environment Do Not Operate in an Explosive Atmosphere In order to avoid damages to the device or personal injuries it is important to operate the device away from an explosive atmosphere Keep Product Surfaces Clean and Dry To avoid the influence of dust or moisture in air please keep the surface of device clean and dry Electrostatic Prevention Operate in an electrostatic discharge protective area environment to avoid damages induced by static discharges Always ground both the internal and external conductors of the cable to release static before connecting Handling Safety Please handle with care during transportation to avoid damages to buttons knob interfaces and other parts on the panels User s Guide for DP1116A III RIGOL Safety Terms and Symbols Terms in this Manual These terms may appear in this manual d WARNING Warning statements indicate the conditions or practices that could result in injury or loss of
27. e output once the power output exceeds the setting value of O V P or O C P so as to effectively protect the load under use User s Guide for DP1116A 2 9 RIGOL Chapter 2 Front Panel Reference O V P The O V P contains Parameter and ON OFF setting Please proceed as follows 1 Parameter setting Press 16V 10A or B2V 5A to select an output scale Press O V P Enter a value within 0 1 V and 35 2 V using the numeric keys and select V or mV as its unit Observe the variety in the O V P input box 2 Enable Disable the 0 V P Press 16V 10A or B2V 5A to select an output scale Press On Off to enable the output of the scale you select Press O V P Press O V P continuously to switch the state of the O V P between ON and OFF Please note the variety in the O V P input box as shown in figure below set 16 000 V rey 16000 V 0 V P ov pul Status 00 000 A ie Value OFF 000 00 W 112A Curr 0 V P O C P Figure 2 7 O V P setting 140A 2 10 User s Guide for DP1116A Chapter 2 Front Panel Reference RIGOL NOTE When the channel output is OFF the O V P function is also disabled but you can set its parameter The output will be automatically shut off once the output voltage exceeds the specified value of the O V P The defaults of the O V P status and value are OFF and 35 2 V respectively User s Guide for DP111
28. e timer setting with parameters auto save NOTE The value of left time Left s in the parameter setting is equal to the setting time Set s when the timer is disabled e If the timing parameters have been specified pressing the rimer at the front panel will turn on the timer When the output is opened the instrument will start the first group of output and the left time Left s will be decreased gradually till 0 then the next group etc The output will stop after all user data has been outputted 2 34 User s Guide for DP1116A Chapter 2 Front Panel Reference RIGOL Built in Help The built in help system enables you to get the help information about each panel key or menu key except for the numeric keys or direction keys The design of this function provides facilities for users to use the panel keys or menu key Press Help its backlight goes on and a character like HELP is shown on the status bar Then press any key except for the numeric keys or direction keys and you will see the help information about this key on the screen at this moment the backlight goes off and the character HELP disappears from the status bar To exit the help topic you are reading press Exit This key relates to the help system Press this k ey to activate the help system and then repress the desired key to get the corresponding help Figure 2 31 Help information User s Gu
29. ee figure below connect the output terminal of the instrument with the load N CAUTION Wrong connection may cause damages to the instrument or the device connected to 2 Turn on the instrument press to start the instrument 3 Scale selection press L6V 10A on the front panel characters below this key are highlighted Voltage setting press Volt and set the voltage to 16 V see Figure 2 5 Current setting press Curr and set the current to 10 A see Figure 2 6 Turn on the output press On Off letters below this key On are highlighted the instrument works under CC mode Dus NOTE In CC mode if the output voltage exceeds the specified value because of the change of the load connected to the instrument will switch into CV mode according to the present voltage value and reduce the output current proportionally Increasing the setting value of the voltage at this moment will resume the CC output 2 8 User s Guide for DP1116A Chapter 2 Front Panel Reference RIGOL Overvoltage Overcurrent Protection In order to keep the power output from exceeding the load rating and avoid damages to the load the DP1116A was designed with the Overvoltage protection O V P and Overcurrent protection O C P functions Users can set the parameters of the O V P and O C P optionally and enable or disable these functions as required if one of these two functions is opened the instrument will cut off th
30. fied voltage current up to 100 groups and simulate the running state of various kinds of power supply more really Operation Steps 1 Press the Timer key at the front panel then a prompt message like Timing will change the output of channel possibly do you go on pops up on the screen if you press OK the backlight of this key will be lighted and a clock icon will be shown on the screen 2 Turn on the output of the current scale Then the timer is enabled and the current channel starts outputting until the end of the timing then the backlight of the Imer key goes off NOTE If no parameters are specified by users pressing Timer will first enter the setting interface of Timer Setting and the backlight of Utility then goes on Inthe process of timing output closing the channel output will stop the timer turning on the channel again will resume the timing output Neither the voltage nor the current can be specified when the timer is on To turn off the timer repress Timer See figure below in General display mode the Set option denotes the setting values of the voltage and current output at present the Next option denotes the setting values of the voltage and current that will be output at the next fixed times 2 14 User s Guide for DP1116A Chapter 2 Front Panel Reference RIGOL Clock icon Specified time 00 000 A 00 000 V D 000 00 W POFF 27 0V e OFF 1 2A V
31. his is the default display mode after you start the instrument See figure below the mode displays the setting values of the voltage current and power in digital form In this mode you can set the values of O V P and O C P set 0 000 V rey 10 000 V 00 000 A w Er d O C P e 1 2 A Curr ORTA z O C P 104 Figure 1 5 General display mode 2 Waveform Display Mode Press Wave Disp to enter the waveform display mode In this mode the voltage current and power are shown in two forms of digits and waves so that users can catch the output status of the instrument easily Beside you can set the values of O V P and O C P as required 1 12 User s Guide for DP1116A Chapter 1 Quick Start RIGOL Waveform display Digits display iN 00 000 A 160 000 00W Figure 1 6 Waveform display mode 3 Classic Display Mode A unique dial design and delicate interface layout in this mode enable users to view the assignable ranges and setting values of the voltage V and current A as well as power W you can press to enter this mode regardless of the current display mode Dial Needle Red line Green line 16 002 V 00 000 A 000 00W Curr O V P Figure 1 7 Classic display mode User s Guide for DP1116A 1 13 RIGOL 1 2 3 Chapter 1 Quick Start Dial See figure above the three dials represent the assigned ranges of voltage current and power respectively Different output scales have
32. i Gove epel oeaciedenedsue tease celteadetneded feneds 2 14 Remote Voltage Sensing sss cesse eee ssss rece s eee eess eee seene neee nenen 2 17 Store anid Recall est sieeve e de See ENEE EE EE 2 19 le te AE dl CN 2 23 T O SOQtUINGS EEN 2 24 System Semings EE 2 27 CANDLES ugeet ele e deet 2 32 Timer dl E 2 33 B iltain Hel EE 2 35 Key Ee EES 2 36 VIII User s Guide for DP1116A Chapter 3 Remote Control eeRKERKKERKREERRKEER KEE KEE KEE KEE KEE KEE KEER KEE KKERen 3 1 Web Control E 3 1 Command CONTON EE 3 5 Chapter 4 TroubleShoOoting csccceseceseeeseeenesenneceneeeeeseeeenaseeaeeeneeeneeeoneas 4 1 Chapter 5 Specifications cccceceeeeeeeeeeeeenseeeneeeeeeoneseneeenaeeeaeeeeeeeeesaoeeas 5 1 Chapter 6 Appendix cccseeeeeeeeeeeeeeeeeeeeneeenaeennesonesooeseneeenaeeeaeenoeeneeeeoenes 6 1 Appendix e TT 6 1 Appendix Br Warranty a KY 2 Tx dev 2 a NSZ 99 9 cox KZ Yg SVN dT yaek SNN 24 a 9 cak yag 6 2 Appendix C General Care and Cleaning ENEE 6 3 Index sekkERRKEREREERRKERRKERRKERR KEE REERRKEER KEE KEE T 1 User s Guide for DP1116A IX Chapter 1 Quick Start RIGOL Chapter 1 Quick Start This chapter introduces the front rear panel the user interface and announcements during first use of the instrument as well as its display mode Subjects in this chapter General Inspection Front Rear Panel and User Interface Front Panel Rear Panel User Interface First Use of DP1116A Power Requirements Power On
33. ide for DP1116A 2 35 RIGOL Chapter 2 Front Panel Reference Key Lock This function is widely used in the industrial production lines for avoiding error operations 1 Local Mode In Local mode holding the number 7 key on the numeric keyboard will lock all keys except itself and the power button and display an icon on the screen To unlock the keys press and hold the number 7 key again 2 Remote Mode In Remote mode the power button and the number 7 key are locked automatically and an icon is shown on the screen To exit the remote control press and hold the number 7 key 2 36 User s Guide for DP1116A Chapter 3 Remote Control RIGOL Chapter 3 Remote Control The DP1116A Programmable DC Power Supply confirms to the LXI C standards 1 2 and provides two ways for remote controlling which are Web and Command Web Control To control you DP1116A via web page please follow the instructions below 1 LAN Setting Use a Net cable to access your DP1116A into LAN then press I O LAN to enter the setting interface of LAN see figure below and follow the I O Settings in Chapter 2 to set the LAN and obtain an IP address LAN Status DHCP IP Addr 172 16 3 30 Volet Auto IP Subnet 255 255 255 0 IP Configure Mode Manual IP Gateway 172 16 3 1 DHCP DNS he Z lie LX MAC 00 1A 9F 12 36 78 VISA TCPIPO 172 16 3 30 INSTR USB GPIB Figure 3 1 LAN setting interface 2 Remote Control Input the obtained
34. ifference menus Display modes Switch the display mode between General Display key Mode and Classic Display Mode Switch the channel scale enable disable the channel Scale key output Output terminal Channel output connectors Advanced Wave Disp display the output signal with function area User s Guide for DP1116A waveforms RIGOL Chapter 1 Quick Start Store Recallj store and recall the instrument settings imer control the timing output Utility set the associated system parameters Sense enable the Sense working mode Help enable the built in help system 1 Panel key indicator 7 The indicator will be lighted and the instrument will be started after you press this button 16V 10A 32V 5A The associated characters below the scale key will be highlighted after you press a scale key On Off The character below this key will be highlighted after you turn on the channel Wave Disp The indicator will be lighted after you turn on the waveform display Imer The indicator will be lighted after you turn on the timer Store Recall The indicator will be lighted after you enter the Store and Recall menu Utility The indicator will be lighted after you enter the system setting menu Help The indicator will be lighted after you enable the built in help system 2 Front panel connectors
35. individually With over voltage over current protection function users can set up the corresponding parameters to achieve effective protection By real color TFT 4 3 inch LCD users can view power supply state clearly by digital displayed voltage current power value and waveform display function which is able to display output voltage current real time Network Introduction DHCP The DHCP Dynamic Host Configuration Protocol provides a framework for passing configuration information to hosts on a TCP IP network If DHCP is ON the values for the IP Address Subnet Mask and Default Gateway have been assigned automatically from the DHCP server Automatic IP Automatic IP determines the values for the IP Address Subnet Mack and Default Gateway IP Address An address used to identify a node on an IP network Each node on the IP network must be assigned a unique IP address which is made up of the network ID plus a unique host ID This address is typically represented with the decimal value of each octet separated by a period for example 192 168 1 3 You can configure the IP address for the instrument statically or dynamically by using DHCP Figure 3 5 Help interface 4 Click Security icon and enter the network security setting interface See figure below enter the passwords as required and click Apply a hint like Note Your password setting successful will be shown on the screen RIGOL Beyond Measure EK a
36. instruments Use a GPIB cable to connect your DP1116A to a PC 2 Set the GPIB address See I O Settings in Chapter 2 select GPIB interface and configure its GPIB address 3 Search the available device Open the Ultra Sigma and click to enter the following interface then click Search to search the devices connected to the PC through GPIB port The searched devices are listed on the right side of the panel see figure below RS232 Setting GPIB Setting Remove OK GPIBO 25 INSTR 25 INSTR GPIBO 25 INSTR l typerchannel Search Figure 3 14 GPIB configurations When cannot search a device automatically Select the address of the GPIB card used in your computer and the GPIB address of DP1116A from the pull down options of GPIB and INSTR respectively Click Test and verify if the GPIB communication is successful If failed please follow the guide step by step 4 View the available devices Click OK and go back to the main screen of the Ultra Sigma The detected GPIB resources are listed under the RIGOL Online Resource 3 10 User s Guide for DP1116A Chapter 3 Remote Control RIGOL LAN GPIB USB TMC RS232 IVI Config Verify All BR RIGOL Online Resource Ee DP1116A IDW Rigol Technolo DP11164 DP1A666 00 01 00 00 01 00 00 01 00 00 Figure 3 15 Available GPIB devices 5 Communication test Right click the DP1116A
37. iod If a product is proven to be defective within the warranty period RIGOL guarantees the free replacement or repair of products which are approved defective To get repair service please contact with your nearest RIGOL sales and service office RIGOL does not provide any other warranty items except the one being provided by this summary and the warranty statement The warranty items include but not being subjected to the hint guarantee items related to tradable characteristic and any particular purpose RIGOL will not take any responsibility in cases regarding to indirect particular and ensuing damage 6 2 User s Guide for DP1116A Chapter 6 Appendix RIGOL Appendix C General Care and Cleaning General Care Do not store or leave the instrument in where the instrument will be exposed to direct sunlight for long periods of time Cleaning Clean the instrument regularly according to its operating conditions To clean the exterior surface perform the following steps 1 Disconnect the instrument from all power sources 2 Clean the loose dust on the outside of the instrument with a lint free cloth with a mild detergent and water When cleaning the LCD take care to avoid scratching it N CAUTION To avoid damages to the instrument do not expose them to liquids which have causticity N WARNING To avoid injury resulting from short circuit make sure the instrument is completely dry before reconnecting it to a po
38. l Em p ay password piy Calibration Timer OFF Giele Not present password Sense OFF 3 Bright Press Bright and enter its setting interface See figure below you can adjust the screen brightness within 1 and 8 by using the or menu key or left right direction keys Set 03 000 V nA nnn W 1 6V Brightness DA 000 00 ES 0 C P a 1 2 A t SP Figure 2 23 Screen brightness setting interface 10A 4 O T P The DP1116A provides two level Overtemperature protection function Pressing O T P can enable or disable the Overtemperature protection function As shown in figure below if you turn on the O T P an icon will be shown on the status bar and the instrument will give you a prompt when the system temperature goes beyond the specified range The second level protection is always on If the system temperature reaches its upper limit the instrument will turn off the channel output 2 28 User s Guide for DP1116A Chapter 2 Front Panel Reference RIGOL O T P icon Figure 2 24 Overtemperature protection setting 5 Beeper Press Beeper from the next page of the system main interface and set the status of the beeper When the beeper is on an icon EI will be shown on the status bar and the instrument will make a buzzing sound once any system message pops up and you will also hear a key tone once a key is pressed down if the beeper is off an icon will be shown on the status bar see figure below 00
39. lay mode Press the Volt or Curr panel key at the front panel and the cursor is then moved into the corresponding parameter input box Increase or decrease the voltage or current value displayed at which the cursor is located by pressing the up M or down mV direction key To move the cursor pressing the left mA or right AN direction key User s Guide for DP1116A 2 3 RIGOL Chapter 2 Front Panel Reference 9 Set 6 000 V rey 16 000 V 0 C P a fr A Curr ORTA O C P Figure 2 3 Direct parameter input TIN 2 Interface setting Press I O LAN or GPIB and enter the corresponding interface data by using the numeric keys To change the parameter item press the up or down direction key to select the item you want click OK to move the cursor press the left or right direction key to delete the parameter you entered press or the left direction key NOTE Pressing and holding the up or down direction key will rapidly and linearly change the setting value while you set the voltage or current value To continuously move the cursor press and hold the left or right direction key To move the cursor in the soft keypad rapidly while you name a file for the storage press and hold a direction key 2 4 User s Guide for DP1116A Chapter 2 Front Panel Reference RIGOL Constant Voltage Output The DP1116A has two modes for power output Consta
40. life d CAUTION Caution statements indicate the conditions or practices that could result in damage to this product or other property Terms on the Product These terms may appear on the product DANGER indicates an injury or hazard may immediately happen WARNING indicates an injury or hazard may be accessible potentially CAUTION indicates a potential damage to the instrument or other property might occur Symbols on the Product These symbols may appear on the product A A mh Hazardous Refer to Protective Chassis Test Voltage Instructions Earth Ground Ground Terminal IV User s Guide for DP1116A RIGOL Environment Considerations The following symbol indicates that this product complies with the applicable European Union requirements according to Directives 2002 96 EC on waste electrical and electronic equipment WEEE and batteries K Product End of Life Handling The equipment may contain substances that could be harmful to the environment or human health In order to avoid release of such substances into the environment and harmful to human health we encourage you to recycle this product in an appropriate system that will ensure that most of the materials are reused or recycled appropriately Please contact your local authorities for disposal or recycling information User s Guide for DP1116A V RIGOL DP1116A Overview RIGOL DP1116A is a single channel Programmable DC Power Supply with up to 1
41. nt Voltage output CV and Constant Current output CC The output mode of the channel is decided by a combination of the specified voltage and current as well as the load connected to the instrument Neither the output voltage nor the current of the instrument can exceed the specified values In CV mode the output voltage equals to the specified voltage value in CC mode the output current equals to the specified current value For example select the 16V 10A scale and separately set the voltage and current to 16 V and 10 A then connect a load with 2 Q 300 W to the instrument As 2 Q x 10 A 20 V gt 16V and 16 V 2 Q 8 A lt 10 A so the channel output the power with constant voltage and current from this scale 16 V 8 A Operation Steps 1 Connect the output leads see figure below connect the output terminal of the instrument with the load Figure 2 4 Output lead connection Select a proper output lead following the table below and use a lead as short as possible AWG 10 12 14 16 18 20 22 24 26 28 Max Current 40 25 20 13 10 7 5 3 5 2 5 1 7 A mQ meter 3 3 5 2 8 3 13 2 21 0 33 5 52 8 84 3 133 9 212 9 Remark AWG is American Wire Gauge User s Guide for DP1116A 2 5 RIGOL Chapter 2 Front Panel Reference A CAUTION Wrong connection may cause damages to the instrument or the device connected to 2
42. olt Curr OAP O C P Figure 2 9 Timing output in General display mode See figure below in Waveform display mode the timing output can be seen from a waveform 93 000 V V L L W il m 160 000 00W 3 000V SEO Volt Curr O V P O C P w vg Figure 2 10 Timing output in Waveform display mode See figure below in Classic display mode we can directly observe the switching process of the timing output parameters User s Guide for DP1116A 2 15 RIGOL Chapter 2 Front Panel Reference 03 000 V 00 000 A 000 00W Curr OM n Figure 2 11 Timing output in Classic display mode 2 16 User s Guide for DP1116A Chapter 2 Front Panel Reference RIGOL Remote Voltage Sensing As the DP1116A can provides 10 A output current and 160W output power the voltage drop in the load leads must not be disregarded In order to ensure the accuracy of the voltage drop while outputting a high current the DP1116A was designed with a Sense remote sense function In Sense mode the system automatically compensates the voltage drop in the load leads so as to ensure the specified output value can be consistent with the value received by the load See the connections below Sense lead gt Sense lead Equivalent lead resistance Equivalent lead resistance Load lead Load lead Figure 2 12 Sense connection NOTE When outputting a high current the load leads should be as short as possible and it would be bes
43. res below Figure 2 1 Unit direction keys left and numeric keys right Al Ki cy 1 Pop up box input this method applies to the following parameter inputs 1 Voltage and Current setting Press Volt or Curr at the front panel Enter a desired value into the pop up box by using the numeric keys 6 Select a unit for the value you entered from the units shown on the menu or at the front panel V mV A or mA Then the instrument will automatically use this value as the setting value in connection with the unit you specify Remark You can use lt key to delete the data entered during the parameter input 2 2 User s Guide for DP1116A Chapter 2 Front Panel Reference RIGOL Pop up input box ka 9 Se 6 000 V 16V IR NNN W 10A IR nov 000 00 W SI 2A mA Cancel Figure 2 2 Pop up box input 2 O V P and O C P setting Press O V P or O C P and enter a desired parameter for the detailed entry method please refer to Voltage and Current setting 3 Calibration and Timer setting Press Calibrate or TimerSet and enter the desired values Note that the unit you specify should match with the current parameter for example only mV or V can be used for the voltage you are setting 2 Direct parameter input modify this method applies to the following settings 1 Voltage and Current setting Switch to the General display mode or Waveform disp
44. ser s Guide for DP1116A Chapter 3 Remote Control Ei DP1116A ICPIP 172 16 3 38 INSTR 2009 12 7 14 16 38 853 Device Clear SystemError Options Read STB Change File Clear History About 10 01 00 00 01 00 00 01 00 00 Figure 3 12 Read and write commands through LAN 6 Load the LXI web page The DP1116A conforms to the LXI C standards Version 1 2 You can load the LXI web page through Ultra Sigma right click the instrument name and select LXI Web from this page you can view the instrument information including the instrument model manufacturer series number description MAC address and IP address See figure below RIGOL Beyond Measure Fi Welcome m Page RIGOL Web Products Service amp Support Network Network Web Status Settings kee Control Help Security Welcome to Web of DP1116A Digital Power Supply Instrument Model DP1116A Manufacturer Rigol Technologies Serial Number DP1A666666666 Description DP1116A L Class C LXI version 1 2 Host Name MAC Address 00 1A 9F 12 36 78 IP Address 172 16 3 38 Firmware Revision 00 01 00 00 01 00 00 01 00 00 VISA TCP IP String TCPIPO 172 16 3 38 INSTR Auto MDIX Capable NO GPIB Address VISA USB Connect String L ep Identification Indicator Figure 3 13 LXI web page User s Guide for DP1116A 3 9 RIGOL Chapter 3 Remote Control 3 By GPIB Please follow the steps below 1 Connect the
45. t 0 01 250 pA Ripple and Noise 20 Hz 20 MHz Normal Mode Voltage lt 350 uV rms 3 mVpp Normal Mode Current lt 2 mA rms Accuracy 12 Months 25 C 5 C output percentage offset Program Voltage 0 05 10 mV ming Current 0 2 10 mA Read Voltage 0 05 5 mV Back Current 0 15 5 mA Resolution Programming 1 mV 1 mA Read Back 1 mV 1 mA Meter 1 mV 1 mA Transient Response Time Less than 50 US is spent on recovering the voltage within 15 mV when the output current changes from full load to half load or half to full User s Guide for DP1116A 5 1 RIGOL Chapter 5 Specifications Remote Sensing Sense Each Sense lead can compensate up to 1V voltage drop for each load lead Command Processing Time 12 lt 50 ms Temperature Coefficient output percentage offset The maximum varieties of Output Read Back for each 1 C change of temperature after 30 minutes warm up Voltage 0 01 3 mV Current 0 02 3 mA Stability 121 output percentage offset Voltage 0 02 1 mV Current 0 1 1 mA Voltage Programming Speed 1 of total variation range Pe Full Load 50 ms Rising No Load 20 ms l Full Load 45 ms Falling No Load 400 ms OVP OCP Accuracy output 0 5 0 5 V 0 5 0 5 A percentage offset l 1 5 ms OVP gt 3 V lt 10 ms OVP lt 3 V Activation Time KEST lt
46. t an input type from English or Chinese Focus Switch the cursor position between the file name entry field virtual soft keypad and the Chinese character display box ABC Switch between the capital and lower case letters abc ABC supports the lower case letters or pinyin abc supports the capital letters Save Save the system configuration file SP Return to the home page of Store Recall Next we will illustrate you how to input a file name in Chinese Example 1 and English Example 2 Example 1 input lt as a file name Press InType and switch to Ch input Switch to ABC and enter a letter b from the soft keypad by using direction keys and press OK Then enter ei in the same way 3 Press Focus and switch to the Chinese character display box and press the up or down direction key until the desired character 1k is displayed and then press the number before this character Then enter 3 445 in the same way Example 2 input Newfile as a file name Press InType and switch to En input Switch to abe and enter a letter N from the soft keypad by using direction keys and then press OK Switch to ABC and enter a letter e from the soft keypad by using direction keys and then press OK Then enter wfile in the same way User s Guide for DP1116A 2 21 RIGOL Chapter 2 Front Panel Referen
47. t if the two leads can twist together in order to obtain a better output characteristic Please use a twisted pair as the Sense lead as possible as you can and the leads should not be twisted with the load leads Operation Steps 1 Connect the output terminals and the Sense terminals at the front panel of the instrument to both ends of the load as shown in Figure 2 12 Please pay attention to the polarity while connecting 2 Press Sense the backlight of which goes on and the icon Sense is lighten User s Guide for DP1116A 2 17 RIGOL Chapter 2 Front Panel Reference Sense icon rey 03 000 V e set 03 000 V 00 000 A zov 000 00 W ET Curr ORTA n O C P TIN Figure 2 13 Sense status 2 18 User s Guide for DP1116A Chapter 2 Front Panel Reference RIGOL Store and Recall The DP1116A supports operations with a USB flash device and local file storage including store recall and delete the parameters about the voltage current O V P O C P and other system setting parameters Besides you can store up to 4 groups of setting files STATE1 STATE2 STATE3 or STATE4 or more into the USB flash device by using the function of Store Recall Press the Store Recalll at the front panel and enter the interface shown below Directory window File window Mobile Disk File location Browser Store Recall Delete gt Figure 2 14 Store Recall interface Table 2 1 Store Recall menu explana
48. ter Input hereinafter inclusive User s Guide for DP1116A Chapter 1 Quick Start RIGOL 3 Inspect the voltage function of the 32V 5A scale Press 32V 5A gt On Off and you will see a character CV shown on the screen which indicates the channel you opened is in Constant Voltage output mode Then check if the voltage in this scale can be set from 0 to 33 6 V maximum rating 3 Current output inspection 1 Press the power button 2 Inspect the current function of the 16V 10A scale Use an isolated test lead to short circuit the positive and negative terminals of 16V 10A Press 16V 10A Set the voltage to 16 V Press On Off and inspect if the current in this scale can be set from 0 to 10 5 A maximum rating 3 Inspect the current function of the 32V 5A scale Use an isolated test lead to short circuit the positive and negative terminals of 32V 5A Press B2V 5A Set the voltage to 32 V Press On Off and inspect if the current in this scale can be set from 0 to 5 25 A maximum rating User s Guide for DP1116A 1 11 RIGOL Chapter 1 Quick Start Display Mode The DP1116A is designed with three display modes General Display Mode Waveform Display Mode and Classic Display Mode The first two modes have their own colors 16V 10A blue 32V 5A red Users can choose an optimal display mode as required 1 General Display Mode T
49. tions Menu Explanation Browser Switch between the directory window and file window Store Enter the storage interface Recall Recall the selected system configuration file Delete Delete the selected file gt Page down m Page up Update Select a desired update file and update the instrument Exit Exit the Store Recall function User s Guide for DP1116A 2 19 RIGOL Chapter 2 Front Panel Reference In the following part we will introduce you how to use the Store Recall function 1 Select a file path Press Browser and switch to the directory window Store the file in Local C local storage or Mobile Disk A USB storage if exists by using the up and down direction keys at the front panel 2 File storage Select a file path take the path from local storage for example the same as USB storage Press Browser and switch to the file window then select a file location by using the up and down direction keys Press Store and input a file name from the interface below Press Save to store the file with a specified name and exit File name entry box Chinese Character display box InType Focus ABC File name entry box En 1 InType Focus Figure 2 16 File name entry interface English 2 20 User s Guide for DP1116A Chapter 2 Front Panel Reference RIGOL Table 2 2 File name menu explanations Menu Explanation InType Selec
50. uide for DP1116A VII RIGOL Contents Guaranty and Declaration ccscccsseceeeeeeeeeeeeeneeeeasenaeeeneseoeeeoaseeaeeeneeeneesnenoas I Safety NOtices ccccccscecneeceeeceeeeeeeeeaseeneeenneeoneeoneeenasenaeeeneseoeseoueeaasesaeeeneenoeenss II General Considerations sE S RT eae etn dee enn ein tice Z ry II Safety Terms and Symbols AAA IV Environment Considerations NEE V DP1116A Overview ssssssssssssss 55 1551555501555500u0uununnnnnnnnnnnnnnnnnn nnmnnn VI Structure of this Document ssssssssssssnunnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn mnnn VII Chapter 1 Quick Start sssssssssssnsnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn nnnm 1 1 General INSPOCtON sanos r a a Eaa aa i dei ea Tae EES 1 2 Front Rear Panel and User Interface 1 3 Front Panel E E E E he cievecveasedeels 1 3 Reat IEN 1 6 User Interface amona a e oi cadens i Uae ane Ea 1 7 First Us of DRUI css eene eeh aaa a atten 1 8 Power Rees iss eesegguEeuESNEek eege SEENEN ETENE ERAST 1 8 ee EE 1 0 Output INSPECTION iiin eni ea arar esnean ea a aaa dis 1 10 Display Mod n Nee Dee EE 1 12 Chapter 2 Front Panel Reference 1 s ccsseccesseeneeeeeeeeeeeeeseeneeeneeeneeeenenoas 2 1 Parameter INPUT cecceecceaceeceavecetaeveevecdsseleccndasnicseececcsertievedchavenesatetasnegeedeetsiees 2 2 Constant Voltage Output 2 5 Constant Current EIERE ssewasccewcicens eae eene d SN a E a a E a S eave aai 2 8 Overvoltage Overcurrent Protection 2 9 TiMNA OULPUb ssia airosa e
51. wer source User s Guide for DP1116A 6 3 Index Index Built in Help a 2 35 Calibrate esas ERS aeaii cS 2 32 ClEANING DE 6 3 Command Control 3 5 Command Processing Time 5 2 Constant Current Output 2 8 Constant Voltage Output 2 5 DC output ratimge sss sss sss sese e 5 1 Display Mode NNN 1 12 Environment 5 2 FOGUS T 2 21 Front Panel 1 3 General Inspection sereen 1 2 E HE 2 26 UO Gettinge sss ssss ees ee eee eee e 2 24 Key LOCK TT 2 36 L t eet een 2 24 Linear Regulation A 5 1 Load Regulation 5 1 Mechanical 5 2 le 5 1 OC Eeer 2 12 OAA a E EE T 2 10 User s Guide for DP1116A RIGOL Output Inspection sss esse sss x eee 1 10 Overvoltage Overcurrent Protection P E E 2 9 Parameter Input 2 2 Power Supp 5 2 Power On Check 1 9 Rear Panel sese sss esec e eee esse eee 1 6 lee 5 1 SDpecITICaiOnS eee eee ee ee ee 5 1 Ele ST 5 2 Store and Recall 2 19 System Settings sse eee eee eee e 2 27 Temperature Coefficient 5 2 Timer Setting 2 33 Timing Output 2 14 Transient Response Time se esse 5 1 Troubleshooting AAA 4 1 DE eet 2 25 User Interface sss s secse ees ssss eee ee 1 7 Utility Setting 2 23 Voltage Programming Speed 5 2 Working Mode of Sense e 2 17 1
52. ximum power from the selected scale can meet the load requirement If meets please Check if the cable that used for connecting the load with the instrument is in good condition or open circuit Check if the load goes wrong Check if a proper voltage in this scale is specified if the value is too low increase it properly If the error still exists please contact RIGOL for help Cannot identify the USB device correctly Check if the USB device is in good condition Check if the used USB device is a flash device note a hard disk cannot be supported by DP1116A Restart the instrument and insert your USB flash device again If the error still exists please contact RIGOL for help User s Guide for DP1116A 4 1 Chapter 5 Specifications RIGOL Chapter 5 Specifications The specification and operating characteristics are based on the instrument having been operated continuously for 30 minutes under the specified operating temperature Note All the specifications below apply to both the two scales unless where noted Model DP1116A Scale 16 V 10 A 32 V 5 A Output Ratings 0 C 40 C Voltage 0 16V 0 32V Current 0 10A 0 5A Overvoltage Protection 0 1 V 35 2 V Overcurrent Protection 0 1A 11A Load Regulation output percentage offset Voltage lt 0 01 2 mV Current lt 0 005 250 HA Line Regulation output percentage offset Voltage lt 0 01 2 mV Current l