Home

ebm-papst EC communication The best connections for a flexible

image

Contents

1. ebm papst Bluetooth Adapter article No 21501 1 0174 alternative RS232 interface converter with cable article No 21500 1 0174 Pocket PC PDA or smartphone with resolution of at least 240 x 320 pixels Windows Mobile 5 for Pocket PC or Windows Mobile 5 Phone Edition or Windows Mobile 6 Classic or Windows Mobile 6 6 1 Premium An always up to date list of compatible devices is available at www ebmpapst com downloads Fan Clone commissioning software for Pocket PC PDA Fan Clone allows you to efficiently program configuration variants produced in small lots After the configuration of one fan is read out and stored the read out or stored configuration is transferred to other fans with or with out changing the device address of the target fan Fan Clone also identifies fans with an unknown fan address Functions The following parameters can be copied onto other fans using this software Operating mode closed loop speed control sensor control PWM control Save set value to EEPROM Source of set values BUS vs analogue input Control function heating cooling Default set value P D factor Maximal speed Min max PWM Start PWM Set value 0 and 1 active with digital interpretation of analogue input Reduction factor Sensor minimum maximum value Sensor unit Run up and run down time Sampling interval of curre
2. Configuring the sensor characteristics for sensor control Configuring the start up and run down ramp soft start MODBUS RTU graphical configuration of the curve of the 0 10 V analogue input 10 V off and 1 V maximum duty cycle are thus no longer a problem MODBUS RTU reset the fan to the factory settings Read out a wide variety of fan parameters Bluetooth The Fan Control mobile software and its sister product Fan Clone are intuitive tools for wireless communication with ebmBUS and MODBUS RTU compatible fan networks Fan Control serves as a diagnostics and configuration tool for visualisation monitoring and programming of fans For this purpose Fan Clone enables simplified commissioning of systems that consist of multiple identically configured fans All configuration tasks and reading out and cloning fan configurations take place easily and conveniently via Bluetooth wireless technology Pf it a e F E r E j k l bm A Tg a aT 1 F Pain p l Aum m Erp hrn ier p n h Lae H C log oo og Joo System version Fan Control 3 1 Item number 25713 2 0199 Delivery scope CD ROM with German and English manuals in PDF format Installation program for every language Video setup guide for the Bluetooth connection Languages German English Spanish French Italian Dutch Finnish Japanese Chinese simplified Chinese traditional Russian System requirements
3. Philosophy Development Application Production Awards GreenTech economy and ecology going hand in hand GreenTech follows a firmly held conviction each newly developed product must exceed the economic and ecological performance of its predecessor To this end we are constantly improving materials and processes flow behaviour and power and reducing energy consumption State of the art energy air conditioning and ventilation technology provides maximum energy efficiency in our plant Numerous environmental prizes distinctions and the groundbreaking energy levels which fall below even the most stringent limits are the reward for our efforts GreenTech pays off for our customers particularly due to the ebm papst EC electronically commutated technology It is not only the heart and soul of our philosophy but also the core of our most efficient products It attains efficiency up to 90 provides maximum energy savings and makes the products maintenance free With integrated open or closed loop control and bus compatibility it is an environmentally sound and in the long run more cost effective alternative to AC technology The right protocol for every occasion Regardless of whether a large number of nodes or broad scope of configuration options and mixed environments are in the focus of EC communication software hardware and interface converters from ebm papst provide smooth data transfer based on ebmBus V3
4. ebm papst eieaa EC communication ry ebmpapst The engineer s choice ebm Dd pst Communication on all channels Fan networks made up of ebm papst EC fans render their service in refrigeration and air conditioning technology in building ventilation clean rooms and many other application areas For communication with the bus systems the ebm papst product range provides various interfaces and software solutions that give you optimum support for setting up and monitoring networks Open and closed loop control programming measuring In addition to their outstanding energy efficiency the intelligent features for open and closed loop control are among the chief advantages of ebm papst EC technology From simply reading out the current speed to configuring a sensor control the integrated electronics of all EC fans offer numerous options for optimally tuned and efficient operation of your system Depending on the planned use application work environment and existing equipment various solutions provide assured communication with your ebm papst EC fans But which software is compatible with which bus sys tem Which interface converter connects which computer to which system On the following pages we provide an overview of the combination options of our visualisation software with the MODBUS RTU and ebmBUS bus sys tems as well as the various communication standards including Bluetooth wireless technology Bluetooth
5. page 18 PDA smartphone Performance features of the control software programs for PCs and PDAs Query and modify parameters of one fan Modify parameters for group entire system Group view floors Detailed error history when software runs for long periods Mapping a system layout floor plan Search for a fan with an unknown address Setting parameters graphically E mail on error Manageability Support for multiple languages Support for RS485 ebmBUS Support for RS485 MODBUS RTU Support of Ethernet and multiple subnets Duty cycle display on fan symbol Display of information below fan symbol Display of the system in a tree structure Support of multiple configurations in one installation German and English user manual PDF Timer Integrated help system English Key Performance feature present Possible in part to a limited extent Not present EC Control Fan Control special or universal Our high performance control programs EC Control software for EC systems EC Control enables visualisation and programming of ebmBUS and MODBUS RTU fan networks and can be configured for both serial and Ethernet inter face converters The software supports the maximum number of devices allowed by the respective bus system up to 7 905 fans for eobmBUS and 247 for MODBUS RTU For shorter latencies multiple interface converters can be connected Where necessary the variable user interface of EC Co
6. 8 pole RJ45 socket 10 100 Mbps autosensing 9 pole SUB D plug TCP Telnet Via LEDs Green left power supply Green right data communication Red fault Plastic housing IP 10 Standard rail mounting in accordance with DIN EN 50022 35 Interface converter Plug in supply unit RS485 cable D Sub to screw terminal Network cable crossover Cat 5 German and English product description Connecting the interface converter Ethernet example of a fan with MODBUS RTU compatibility The Ethernet interface converter serves to integrate bus compatible EC fans into existing computer networks This increases the spatial independence of the control room and fans Other than a power supply all that is needed is a static IP address which can be assigned easily using the EC Control software Multiple Ethernet interface converters can be used without any problems This allows for example larger systems to be divided up spatially to reduce latencies Note for large systems After 31 fans a repeater can be installed in order to connect another 31 fans External sensor Pressure sensor temperature sensor Power supply Fans Interface converter Ethernet Art No 21488 1 0174 Art No 21489 1 0174 s ER Example terminal assignment for fan EJ Interface converter connection KL3 KL2 PE
7. 600 pixel resolution and 8 bit colour depth CD ROM drive for installation only RS232 interface for laptops a PC card can also be used but not a USB RS232 adapter At least one interface converter of the following types e RS232 article No 21487 1 0174 with electrical isolation e RS232 article No 21495 2 0174 Communication without cable clutter The control software programs for Pocket PCs Fan Control software for Pocket PC PDA Fan Control is compatible with both ebmBUS and MODBUS RTU devices The software has graphical and numerical configuration options allows you to save data records and two parameter sets e g for daytime and nighttime operation Using an emergency operation function you can define a set value that the fan defaults to automatically if no bus communication takes place for a configurable time period Functions Monitoring of fan groups Fan status display Programming individual fans e g changing the fan s address Changing the control mode of the fan speed control PWM con trol sensor control Changing set values speed direction of rotation etc Setting closed loop control parameters graphically too Changing minimum maximum values Graphical configuration of minimum and maximum PWM as well as set value for sensor control pure P controller also the control range Read out of fault status Search for unknown device addresses
8. KL1 yejelaalgE CO m PIR lt ta een 9 ee 22 57 l ze Ne ESE C A RSA 5 A B B RSB 17 EC controller Nominal data Type Nominal voltage Frequency Power consumption Power supply for sensor Output current Permitted ambient temperature Permitted storage temperature Dimensions Stand alone control device for refrigeration and air conditioning technology in conjunction with the corresponding sensors Using the controlled 0 10 V output or RS485 MODBUS RTU connection ebm papst fans with a corresponding input can be triggered The function includes multifunctional pressure and temperature control as well as display and entry of various parameters The integrated LCD display provides easy operation across multiple levels CCC000 AD06 02 V 1 200 480 Hz 50 60 W 15 VDC 24 mA 120 C 0 to 60 C 20 to 60 mm 200 x 167 x 76 Specifications subject to change Inputs outputs Applications Sensors Menu languages Housing Product conforming to standard Type of protection EMC Installation 24V power supply for sensors Analogue inputs for connecting up to 2 sensors per type 4 digital inputs 2 programmable relay outputs 2 voltage outputs 0 10 V RS485 MODBUS RTU Temperature control standard Pressure control of ventilation systems condensers 2 circuit condensers Pressure control ambient temperature compe
9. and MODBUS RTU two bus protocols that are particularly well suited for EC technology For even more freedom of choice in implementation control programs such as Fan Control for PDAs and EC Control for PCs even support both standards RS485 ebmBUS the specialist for a high number of nodes This bus protocol developed by ebm papst specifically for the require ments of EC technology is perfectly designed for situations in which a large number of fans with little need for individual configuration are to be controlled Up to 7 905 slaves can communicate with one master PC PDA For this purpose the Fan Control software program is avail able for mobile terminal units and LISA 5 as well as EC Control for PC based platforms RS485 ebmBUS which has been continuously further developed and is now in its third generation has proven to be a robust communication protocol that is equally easy to implement and use Clean rooms are a typical application area Decide at a glance what is most important to you RS485 ebmBUS Baud rate 9 600 Parity none Number of nodes up to 7 905 Profiles Broadcast commands Devices in the bus only ebm papst Configuration options good Fault detection XOR Fault memory last 3 Software support EC Control LISA5 Fan Control Fan Clone On installations with more than 31 fans RS485 repeaters have to be used depending on the type of fan RS485 MODBUS RTU open standard with wide range of function RS4
10. 400 and 43030 0001 ISM band 2402 2480 MHz Via LED Green power supply OK Yellow flashing Bluetooth connection active Red top left of green LED data transmission from PDA smartphone to fan Red bottom left of yellow LED data transmission from fan to PDA smartphone Plastic housing IP 20 Bluetooth Adapter and 4 conductor connecting cable with corresponding Molex plug and core end sleeves German and English product description Connecting the Bluetooth Adapter example of a fan with MODBUS RTU compatibility The Bluetooth Adapter is connected directly to the fan The fan voltage of 15 or 20 V is used for the power supply of the adapter so that no external power supply is required Note Reversing the voltage does not present any problems for the Bluetooth Adapter even if the fan displays an error regarding this The Bluetooth Adapter works in the same licence free 2 4 GHz frequency band in which Wireless LAN networks operate The frequency hopping method used here provides immunity to interference Note Only one Bluetooth Adapter is needed for communication with a system no matter what its size External sensor Pressure sensor temperature sensor Power supply O Fans i l eee MODBUS RTU RSA RSB Bluetooth Adapter a i ebm papst Bluetooth Adapter Art No 21501 1 0174 PDA Smartphone Bluetooth Bluetooth ER Exampl
11. 85 MODBUS RTU which came into being back in 1979 has become established as a worldwide standard for controlling actuators and sensors not least due to its open protocol A great number of settings can be con figured easily for up to 247 slaves Each fan is assigned two parameter sets They allow you to save different configurations for example for summer and winter time day and night or standard and high performance mode Three data sets per EC node also provide the ability to implement backup functions In combination with read write authorisations an extensive fault memory and an emergency operation function RS485 MODBUS RTU fea tures outstanding characteristics in terms of both operating convenience and reliability Typical application area in this case refrigeration and air conditioning technology RS485 MODBUS RTU 19 200 even up to 247 ebm papst and others outstanding CRC16 last 13 EC Control Fan Control Fan Clone The perfect match supported interfaces and protocols Software EC Control LISA 5 page 6 page 7 Hardware PC laptop PC laptop Bluetooth adapter page 10 RS232 RS485 interface converter with electrical isolation page 12 RS232 RS485 interface converter without electrical isolation page 14 Ethernet R8485 interface converter page 16 RS485 ebmBUS RS485 A MODBUS RTU Fan Control page 8 PDA smartphone Fan Clone EC controller page 9
12. E El alialialia q lt A cile NON Ss NI ol amp EEEN AE sS l AR aaea oc cc did S allie ASW NEES alea y gt gt ASSESSES elle el sigs HHTHARKGHAHHAHHHFFIRE ce ce SO O allo In this brochure we hope to give you a comprehensive overview of how the hardware and software of our EC communication products interact If you have any other questions about a specific application please do not hesitate to contact us Our specialists will be happy to help ebm papst Mulfingen GmbH amp Co KG Bachmuhle 2 D 74673 Mulfingen Phone 49 7938 81 0 Fax 49 7938 81 110 infol de ebmpapst com www ebmpapst com 37818 7 8811 wob 01 10 2 ebmpapst
13. ave many thousands of fans System version EC Control 1 01 Item number 25714 2 0199 Delivery scope CD ROM with Software German and English manuals in PDF format Quick video guide Languages German English System requirements Windows 2000 SP4 or higher XP SP3 or higher Vista SP1 or higher 30 MB of free hard drive space 512 MB RAM for Vista at least 1 GB RAM recommended CPU Pentium Ill or higher 800 MHz or comparable for simultaneously operation with multiple interface converters a faster CPU is recommended Monitor with at least 1024 x 768 pixel resolution and 16 bit colour depth CD ROM drive for installation only At least one interface converter of the following types e RS232 article No 21487 1 0174 with electrical isolation e RS232 article No 21495 2 0174 e Ethernet article No 21488 1 0174 e Ethernet UL certified article No 21489 1 0174 LISA 5 control software for EC systems LISA 5 is the control software specially developed for ebmBUS It is com patible with all EC motors and electronics that are networked via ebmBUS The group oriented arrangement of the fans enables individual control and monitoring of a maximum of 7 905 fans in up to 255 groups on 10 floors Using broadcast commands individual groups or all fans can be triggered simultaneously Functions Individual control and monitoring of max 7 905 fans including the ab
14. e terminal assignment for fan KL3 KL2 PE KL1 AICI Sie 5 mi i sii iiz 11 Nominal data Nominal voltage and plug in supply unit VAC 230 Power supply VAC VDC 12 14 Current draw at no load operation mA 150 Dimensions mm 105 x 75 x 22 Operating mode Safety Electrical isolation ESD immunity RS232 connection RS485 connection Terminating resistor Status display Housing Installation Delivery scope 12 RS485 two wire mode with echo and automatic control Electrical isolation between RS232 and R8485 Min 1kV isolation voltage between RS232 and RS485 interfaces and between power supply and interfaces Up to 15 kV acc to IEC 801 2 Stage 4 9 pole SUB D plug with PC COM assignment 9 pole SUB D plug built in activated via switch Via LEDs Green supply voltage OK Red data transfer Plastic housing Standard rail mounting in accordance with DIN EN 50022 35 Interface converter Plug in supply unit 230 VAC 12 VDC 500 mA Adapter lead to the computer with 2 x 9 pole SUB D sockets Adapter lead to the fan with 9 pole SUB D socket and RS485 screw terminal Product description and manual German and English Connecting the interface converter example of a fan with MODBUS RTU compatibility In conjunction with the EC Control or LISA 5 programs connections for bus compatible fans can be implemented easily using a computer or laptop No special setup of the interface converter is
15. ility to report failures by e mail Group oriented arrangement of the fans Level 1 Overview display for up to 10 floors Level 2 Overview display for up to 255 groups within a floor Level 3 Overview display for 31 fans within a group Broadcast command for one group or all fans Speed temperature or pressure control Error message Fan status display Programming individual fans e g changing the fan s address Changing the control mode of the fan speed control PWM control sensor control Changing set values speed direction of rotation etc Configuring control parameters Changing minimum maximum values Read out of fault status Identification of a fan with unknown fan address Configuring the sensor characteristics for sensor control Configuring the start up and run down ramp soft start 1E E eee ee eee IH ne J ITTI a a i i 1h mA ia Bi h J 1 f l f E ie i i ee ti i System version LISA 5 1 Item number 25711 2 0199 Delivery scope CD ROM with software Languages German English Spanish French Italian Dutch Finnish Japanese Chinese simplified Chinese traditional Russian System requirements Windows 2000 XP 21 MB of free hard drive space 128 MB RAM CPU Pentium 200 MHz or higher or comparable Monitor with at least 800 x
16. nsated These applications are the factory defaults Other applications can be programmed individually Temperature sensor KTY 10 6 R25 2 KQ NTC 103AT R25 10 KQ Pressure sensor 0 to 100 200 500 1000 Pa 0 10 V output 0 to 30 bar 4 20 mA output ebm papst temperature sensors Art No 50003 1 0174 and 50005 1 0174 Other sensors can be programmed individually German Swedish Danish English factory setting Plastic housing CE IP 54 acc to DIN EN 60529 Acc to EN 61000 6 3 and EN 61000 6 2 Vertical wall mounting direct solar radiation and installation on vibrating substrate is not permitted Electrical leads via terminal strips Connecting the EC controller example of a fan with MODBUS RTU compatibility The EC controller functions as a stand alone control device for fan networks in combination with external sensors Factory default applications ensure easy commissioning connecting a computer or other software supported devices is not necessary For programming new applications and for monitoring an integrated keypad control with LCD display replaces the external input devices External sensor Pressure sensor temperature sensor EC controller EE Example terminal assignment for fan EJ Example terminal assignment EC controller KL1 1 2 3 2 w 5 oO KL3 KL2 PE KLI KL2 KL3 N L aA alovla gt n w
17. nt regulator Source for control function bus vs external terminal switch Qutput function of analogue output Qutput curve of analogue output Emergency operation function MODBUS RTU ebmBUS SS iasi San ds Por it Benue cnet eee me System version Fan Clone 2 0 Item number 25715 2 0199 Delivery scope CD ROM with English manual in PDF format Installation program Video setup guide for the Bluetooth connection Language English System requirements ebm papst Bluetooth Adapter article No 21501 1 0174 alternative RS232 interface converter with cable article No 21500 1 0174 Pocket PC PDA or smartphone with minimum resolution of 240 x 230 pixels and Bluetooth interface Windows Mobile 5 for Pocket PC or Windows Mobile 5 Phone Edition or Windows Mobile 6 Classic or Windows Mobile 6 6 1 Premium An always up to date list of compatible devices is available at www ebmpapst com downloads Nominal data Power supply VDC reversible 15 24 Current draw mA 30 Transmitting power mW 1 Range depending on ambient conditions m 10 20 Dimensions mm 100 x 50 x 25 Operating mode RS485 connection Frequency band Status display Housing Type of protection Delivery scope Bluetooth 10 RS485 two wire mode without echo automatic switchover between send and receive Molex Minifit socket compatible plug Molex article No 43025 0
18. ntrol makes it easy to distinguish between the various interface converters It shows only the entries that are relevant to the specific system Additional features include support of a second monitor a tree shaped management structure for finding indi vidual fans in large systems efficiently and an online help Functions Configuring over 40 fan parameters such as operation mode set values and control parameters Changing fan addresses Reading out fan parameters such as actual speed serial number and production date Reading out fault status and fault memory Saving various configurations as an exportable and editable profile Monitoring installations including the possibility of reporting failures by e mail Administration of multiple systems within one program installation Support for RS232 RS485 and Ethernet RS485 interface converters Simultaneous monitoring of eomBUS and MODBUS RTU based system components requires several interface converters The ebm papst EC Control and LISA 5 control programs enable detailed control and monitoring of fan groups in eomBUS or ebmBUS and MODBUS RTU networks The multilingual and intuitively operated interfaces in the familiar Windows system environment provides you with easy and logical control For example you can position fans on the floor plan of your storey in a simple and clearly arranged manner This lets you always keep tabs on your networks even if they h
19. required Note Because of the electrical isolation use in even large networks with potential differences is possible without any problems Note for large systems After 31 fans a repeater can be installed in order to connect another 31 fans External sensor Pressure sensor temperature sensor Power supply Fans Interface converter Art No 21487 1 0174 Zt s Power supply plug unit Interface converter ER Example terminal assignment for fan EJ Interface converter connection KL3 KL2 PE KL1 yejelaalgE CO m PIR lt lt SIEI B 2 z E 2 5 5 S S 2 fai s s A RSA 5 A B B RSB Nominal data 73 X 37X19 7 12 Dimensions Power supply mm VDC Otherwise via RS232 DTR TxD and RTS signal Operating mode Status display Housing Terminal Terminating resistor Delivery scope 14 RS485 2 wire mode with echo and automatic control Via LEDs PWR Power supply TXD Data transfer send RXD Data transfer receive Plastic housing Screw terminal TRX RSA TRX RSB Built in activated via switch Interface converter English language operating manual Connecting the interface converter example of a fan with MODBUS RTU compatibility The combination with the EC Control and LISA 5 programs enables cost effective programming and monito
20. ring of bus compatible EC fans The interface converter can be connected directly and used without any special setup Note The interface converter does not have any electrical isolation and thus is suitable for battery operated devices only The switch on top of the interface converter must be set to RS485 External sensor Pressure sensor temperature sensor Power supply Fans Interface converter Art No 21495 2 0174 ER Example terminal assignment for fan EJ Interface converter connection KL3 KL2 PE KL1 yejela alsz CO m PIR lt Ss TRX TRX GND RX RX xjayajriSielit lollZlle wl jellalie eo S Faia ENSz aa 15 Nominal data Operating mode Safety Electrical isolation Ethernet connection RS485 connection Protocols used Status display Housing Type of protection Installation Delivery scope 16 Nominal voltage and plug in supply unit VAC 100 240 100 240 Power supply VDC 12 48 12 48 Current draw mA 85 85 Frequency Hz 50 60 50 60 Ambient temperature arranged in series C 0 to 50 0 to 50 Ambient temperature not arranged in series C 0 to 60 0 to 60 Dimensions mm 105 x 75 x 22 105 x 75 x 22 RS485 two wire mode without echo automatic switchover between send and receive Electrical isolation between Ethernet and RS485 min 500 V

Download Pdf Manuals

image

Related Search

Related Contents

    English  業務用ディフューザーカタログ  Schnellanleitung REMOVAL AIRBAG SYSTEM  User Manual - AmericanPumpkins.com: Product Support  PS PROGRAMMER  

Copyright © All rights reserved.
Failed to retrieve file