Home

Installation

image

Contents

1. CNBM INTERNATIONAL CORPORATION es PV module installation Use the long side of module frame as top bottom side with installation holes to install modules If PV modules were blow away it will be very dangerous Applying M6 or M8 stainless steel screws with power about 5 8N M In salty area please take appropriate methods to prevent solar modules from corrosion Wiring and connection 900mmxX4mm_ cable for CNBM 160D CNBM 180D solar modules Temperature for interior and exterior of the cable can t exceed 85 C 55 separately Diodes were installed in the solar modules If solar modules from CNBM were connected with other solar modules the output of power generation will be deteriorated and may cause bad effect to solar modules So please avoid this When PV modules are generating DC electricity please use the diodes or other applicable methods to prevent reversed current Diodes are not subsidiary components of the solar modules Note Parallel configuration is not limited in case of taking proper measure e g fuse for protection of module and cable from over current and or blocking diode for prevention of unbalanced strings voltage to block the reverse current flow Please make sure that all the information described in the installation manual is Page 17 of 20 Everything For Green Econergy CMAX CNBM INTERNATIONAL CORPORATION still valid and proper for your installation The moun
2. CNBM USA CORP 17800 castleton st suite 558 City of Industry CA 91748 USA Phone 0016268106368 Fax 0016268106853 E Mail sales cnbmsolar com Website www cnbmsolar com Page 22 of 20
3. may result in electric shock There is risk of electric shock or injury Do not damage or D Qo Do not prick back of solar process wiring material P module with sharp objects which may cause risk of electric 4 otherwise may result in electric shock shock electricity leakage or make solar module damaged Don t stand on or step on the solar modules because the solar module may be damaged and people may be injured if slip down Page 10 of 20 Everything For CMAX LAMH Least aequas priae Green Econergy 36 INTERNATIONAL CORPORATION 1 2 don t touch solar modules O The module will become high temperature under sunshine and may cause a risk of scalding Page 11 of 20 Everything For Green Econergoy CMAX CNBM INTERNATIONAL CORPORATION Warning Dont open cover of junction box and clean inside with liquid it may result in Dont immerse the solar modules in electrical shock liquid it may result in electrical shock Do not use damaged A A Qo Don t deform mend solar abnormal solar module module it result in which may cause risk of an electric electric shock or be wounded shock If so please contact CNBM O Don t stand or step on solar module The module may be damaged due to its glass surface and it may make person injured when they slip down Don t touch the cable of the solar module since DC electricity will be produce
4. When installing wiring or maintaining modules in order to prevent producing the DC electricity please cover the module surface with sufficiently opaque stuff E When installing wiring or maintaining modules please use protective instruments such as rubber gloves E Do not connect the PV modules directly to the loads such as motor since the variation of the output power depending on the solar irradiation cause damage for the connected motor 1 In the case of a blushless motor the lock function becomes active and the hall IC is most likely to be damaged 2 In the case of a brush type motor the coil is most likely to be damaged If high reliability is required the machine is related to personal life please don t use those modules Hi Output is unstable Serious accidence such as lethal injure may occur Page 7 of 20 Everything For CMAX CAM Laura aal spa stam Green Econergy CNBM INTERNATIONAL CORPORATION Warning for Installation Ia 1 Always wear protective head gear insulating gloves and safety shoes with rubber soles 2 Keep the PV module packed in the carton until installation 3 Completely cover the PV module surface with an opaque material during PV module installation and wiring 4 Plug in the connector tight and ensure the wiring work 5 Wear a safety belt if working far above the ground Bind cables by the insulation locks Drooping down of cables from the terminal box could possibly cau
5. the electric power generation is adequate when the sunlight is the scarcest then the angle chosen should be adequate during the rest of the year For grid connected installations where the PV module at the angle equal to the latitude of the installation site so that the power generation from the PV module will be optimum throughout the year VO A tilt angle PV module will get maximum output of power generation when sunlight irradiates on their surfaces vertically But if operating time and operating purpose are limited the above mentioned design may not be optimum Page 15 of 20 Everything For Green Econergy oom CMAX LAG bua Cae py atiam CNBM INTERNATIONAL CORPORATION eras In order to make PV modules have a long service life outside please pay attention to the following items Adopting strong and safe structure Choosing appropriate materiel for solar modules Adopting appropriate method for anticorrosion Following all kinds of regulations concerned Don t damage any parts of modules for power generation The site shall be in compliance with ambient and climate Be easy to maintenance The foundation shall be done by professional designer or construction company The assembly is to be mounted over a fire resistant roof covering rated for the application Page 16 of 20 Everything For CMAX A Green Econergy
6. 0 Everything For Green Econergy O CMAX CNBM INTERNATIONAL CORPORATION TREM 1 linnal Caras atlas 1 Stainless steel M8 nut 2 Stainless steel washer 3 Stainless steel M8 t head bolt B V Wiring Please observe the correct cable connection polarity when installing the modules If not connected properly the bypass diode could be destroyed PV modules can be wired in series to increase voltage as shown in figure SERIES WIRING VOLTAGE ADDITIVE PV modules can be wired in parallel to increase the current as shown in figure 2 Page 20 of 20 Everything For Green Econergy CMAX CNBM INTERNATIONAL CORPORATION Page 21 of 20 Everything For Green Econergy CMAX CNBM INTERNATIONAL CORPORATION Maintenance amp Inspection Routine Inspection It is unnecessary to do inspection everyday our suggestion is one time for one year If the dirt were built up please clean the surface with soft sponge with water Inspection for Wind and Rain Hazard or Earthquake When wind and rain hazard or earthquake happens please check whether something dropped on the PV modules and made some damages to them Inspection for Salt Snow Hazard Please make a schedule to inspect whether PV modules were corroded After heavy snow please check the condition of solar modules CNBM reserve the right to revise the models contents without notice
7. Everything For Green Econergy CMAX CNBM INTERNATIONAL CORPORATION CNBM International Corporation Solar Module Installation and User Manual Thank you for selecting solar panel from CNBM In order to use the solar panels properly please read this Installation Manual carefully and completely before any operating Catalogue About Solar Panel Page 2 Performance and Characteristics Page 3 Safety Warning Page 4 9 Installation Page 10 16 Maintenance amp Inspection Page 17 The modules are qualified for application class A Hazardous voltage IEC 61730 higher than 50V DC EN 61730 higher than 120V hazardous power applications higher than 240W where general contact access is anticipated modules qualified for safety through EN IEC 61730 1 and 2 within this application class are considered to meet the requirements for safety Class II Page 1 of 20 Everything For CMAX CNBM T na apr na liuta agg at Lam Green Econergy CNBM INTERNATIONAL CORPORATION hd What is solar panel Solar panel is a big semiconductor PN diode which can transfer sun energy to electrical energy without any help from mechanical energy and it is a quiet and clean energy generator which can create DC electricity continuously under the sunlight Theory Under the sunlight the cells in the modules will produce electrons and cavities by photo emission which is influenced by internal electrical field the electro
8. NTERNATIONAL CORPORATION CNBM 270 Class 24 1 15A 35 840 5V 7 54 0 5 43 0 0 5V 8 45 0 5A 1000 CNBM 270P 2 5 Class A 24 1 15A 35 840 5V 7 68 0 5 43 0 0 5V 8 60 0 5A 1000 CNBM 275P 280 Class A 24 1 15A 36 040 5V 7 78 0 5 43 2 0 5V 8 72 0 5A 1000 CNBM 280P 285 Class A 24 1 15A 36 040 5V 7 92 0 5A 43 2 0 5V 8 87 0 5A 1000 CNBM 285P 290 Class A 24 1 15A 36 040 5V 8 06 0 5A 43 2 0 5V 8 97 0 5A 1000 CNBM 290P 200 Class A 30 1 15A 28 5 0 5V 7 02 0 5 34 2 0 5V 7 86 0 5A 1000 CNBM 200P 205 Class A 30 1 15A 28 5 0 5V 7 19 0 5 34 2 0 5V 8 05 0 5A 1000 CNBM 205P 210 Class A 29 1 15A 29 0 0 5V 7 24 0 5A 34 840 5V 8 11 0 5A 1000 CNBM 210P 215 Class A 29 1 15A 29 0 0 5V 7 41 0 5 34 840 5V 8 30 0 5A 1000 CNBM 215P 220 Class A 28 1 15A 29 5 0 5V 7 46 0 5 35 44 0 5V 8 36 0 5A 1000 CNBM 220P 225 Class A 28 1 15A 29 5 0 5V 7 63 0 5 35 4 0 5V 8 55 0 5A 1000 CNBM z ll Max Over curren Current at Open Short Voltage at point of Application Maximum Maximu m Max System Power oint of max Circuit Circuit ass series Voltage Current vee puel configuratio parallel Protection Voc Isc A ns configura Impp A tions V V U 30 040 5V 7 67 0 5A 36 0 0 5V 8 59 0 5A 1000 CBN 28 15A Page 4 of 20 Everything For CMAX LAG bua Cae py atiam Gre
9. d when solar module is under sunlight please pay attention to this to avoid electrical shock Page 12 of 20 Everything For Green Econergy on CNBM INTERNATIONAL CORPORATION CMAX d meas atiam A Warning Installing repairing removing and resetting solar modules shall only be done by professionals Caution Don t put heavy objects on solar module Don t let optical lens and other spotlight objects to shine the modules directly Don t toss or drop the solar modules Installation shall be in accordance with CSA C22 1 Safety Standard for Electrical Installations Canadian Electrical Code Part 1 Attention for installation The modules shall be mounted so that the junction box shall be in the uppermost position to minimize the ingress of water In case of series connection the maximum open circuit voltage must not be greater than the specified maximum system voltage The voltage is proportional to the number of series In case of parallel connection please be sure to take proper measure e g fuse for protection of module and cable from over current and or blocking diode for prevention of unbalanced strings voltage to block the reverse current flow The current may easily flow in a reverse direction Page 13 of 20 Everything For Green Econergy CMAX CNBM INTERNATIONAL CORPORATION Ske Selection Please make sure that there is no obstruction in the surroundings of the s
10. en Econergy on CNBM INTERNATIONAL CORPORATION 4 With 72x5 mono c Si cells oh w al Open Max System nea ii Over curren oint of max ircui ower ne Volta Mu configuratio parallel Protection power configura mpp V Impp A Voc tone 350405 449 05A 420 05V 49505A OSA 1 350 05 45705 420 05V S205 100 f CMM Cesa 2 1 ov Voltage at Note Rated electrical characteristics are within 10 percent of the indicated values of lse Voc Pm under Standard Test Conditions of 1000W m Am 1 5 spectrum and a cell temperature of 25 C 77 F Page 5 of 20 Everything For Green Econergoy CMAX CNBM INTERNATIONAL CORPORATION In order to use the modules properly avoiding property losses or injuring the operater or anyone else warnings and some other caution signs are printed on the solar modules and Manuals 9 Sign Introduction Introduction Warning Caution Means Misoperation will cause a risk of lethal or personal serious injury Means Misoperation will cause a risk of injuring or porperty loss 9 Graph introduction Introduction Prohibited proceeding not permitted a The details will be described in the signs graphs and texts Compulsion proceeding is compulsory The details will be described in the signs graphs and texts Caution Warning included The details will be described in the signs or graph
11. he glass may be damaged and cause injury due thunder avoiding rod etc Each PV to libration module has a hole on each side with a grounding sign An example of ground connection using a bolt nut and washer retaining a ground lug Do not touch the PV module unnecessarily is shown in the following figure The during installation The glass surface and screwing rate for nut is about 1 2 N M the frames get hot There is a risk of burn or you may collapse because of electric shock Alternately the grounding and bonding equipment type 1954381 1 by Tyco Do not work under rain snow or windy Electronics Corp can be used to provide the conditions grounding connection to the module frame as illustrated in the following diagram Grounding of Solar Panels FRAME LOCK NUT I TOOTH WASHER i WIRE 1 GROUND TERMINAL 1 H GROUND BOLT SCREW TERMINAL Remarks Screw size M5 screw Earth cable diameter please use a 4mm earth cable Page 9 of 20 Everything For CMAX LAG bua Cae py atiam Green Econergy 2 CNBM INTERNATIONAL CORPORATION JUNCTION BOX MOUNTING HOLES WASHER 1 Stainless steel nut 2 Stainless steel serrated washer MOUNTING HOLES uo 3 Stainless steel washer a x 4 4 2 9 39 e 9 n on s n t om on on Do not open cover of junction box it Qo Don t let children approach modules
12. ite of installation And select the site without shadows from trees or buildings enabling the module to be shined by sun frequently Especially in very hot weather please pay attention the modules cant be shadowed partly Furthermore in different season the dimension of shadow caused by plant or any other objects will be changed and may shadow some portions of solar modules resulting in power generation reducing Take proper steps in order to maintain reliability and safety in case the PV modules are used in areas such as heavy snow areas extremely code areas strong wind areas installation over or near water areas where installations are prone to salt water damage small islands or desert areas Installation direction In the Northern Hemisphere the PV modules should typically face south and in the Southern Hemisphere the PV modules should typically face north Tilt angle The title angle of the PV module is the measured between the PV module and a horizontal ground surface The PV module generates the maximum output Page 14 of 20 Everything For CMAX CNBM CHEN interns tions Corpe ation Green Econergy CNBM INTERNATIONAL CORPORATION power when it faces the sun directly For the standalone systems with a battery where the PV modules are attached to a permanent structure the tile angle of the PV modules should be determined to optimize the performance when the sunlight is the scarcest In general if
13. ns will go towards and assemble at N silicon and cavities will go towards and assemble at P silicon As a result the electromotive force will occur if they are connected with exterior load the DC electricity will be created 7 19 solar energy Exterior electrical polarity Apnti reflectance coatue N siicon FN F silicon Internal electrode Diagram for Solar Module function Page 2 of 20 Everything For CMAX LAG bua Cae py atiam Green Econergy CNBM INTERNATIONAL CORPORATION The module is high efficient due to adopting high efficent cell The module is high reliable due to adopting high transparent tempered glass The structure of module is wind resistant From CNBM 240P to CNBM Voltage at point of max Current at p Short Maximum Over curren point o Circuit Max System Application series max Current cass ower Voltage configuratio parallel Protection mpp V pons Moe QD Isc A V ns configura Impp A tions 30 040 5V 6 86 0 5 42 0 0 5V 7 68 0 5A Class A 24 1 15 35 0 0 5V 7 0 0 5 42 0 0 5V 7 84 0 5A Class A 35 3 0 5V 7 08 0 5 42 440 5V 7 93 0 5A Class A 35 3 0 5V 7 22 0 5A 42 4 0 5V 8 09 0 5A Class A 260P 5 540 2 0 39 5 0 5V 7 32 0 5 42 6 0 5V 8 20 0 5 4 3 Page 3 of 20 Everything For CMAX LAG bua Cae py atiam Green Econergy on CNBM I
14. s and texts Page 6 of 20 Everything For NA CLAM Ln aum Green Econergy CNBM INTERNATIONAL CORPORATION Solar module installation maintenance removal and resetting shall only be done by professionals Before you attempt to install wire operate and maintain the PV module please make sure that you completely understand the information described in this installation manual If there were defects there is a risk of electrical shock or fire When installing wiring operating removing and maintaining modules pay attention to the risk of electrical shock If module is shined by sunlight or other illuminator the DC electricity will be produced E Artificially concentrated sunlight shall not be directed on the module S Under normal conditions a photovoltaic module is likely to experience conditions that produce more current and or voltage than reported at standard test conditions Accordingly the values of ISC and VOC marked on this module should be multiplied by a factor of 1 25 when determining component voltage ratings conductor ampacities fuse sizes and size of controls connected to the PV output please refer to Section 690 8 of the National Electrical Code for an additional multiplying factor of 125 percent 80 percent derating which may be applicable S if modules are connected in series or parallel the voltage and current will increase AN the danger will be increased tremendously accordingly AN
15. se various problems such as animal biting electricity leakage in puddle Installing maintaining removing and Don t stand or stamp on the solar resetting modules shall only be done modules There is a risk of injury by professionals electric shock if glass is broken and it is slippery which may make injury to someone Do not touch the terminal box and the Don t wear steel stuff end of output cable ends connectors like rings There is a risk of with bare hands during installation or electrical shock under sunligh regardless of whether the PV module is connected to or disconnected from the syste Also do not perform any work if the terminals of PV module are wet Qo Sharp stuff prohibited It Don t put wires between frame and prop puncture the back of module The wire may be damaged and cause 1 There are risks of electrical shock and fire electrical shock electricity leakage and solar module s service life may be shortened When connecting modules with Dont damage or process ther controlling device please entrust wiring material It may cause _rofessionals a risk of electrical shock Page 8 of 20 Everything For Green Econergy CMAX CNBM INTERNATIONAL CORPORATION Grounding If not connected properly it will cause a Dont install solar modules on movable risk of electric shock Please don t Qo objects such as doors vehicles connect the cable with any other pipes such as gas pipe water pipe T
16. ting method has been verified by CNBM and NOT CERTIFIED by a third party organization The approved way to mount CNBM PV modules to a support structure is using the bolt holes provided as described in the specifications Although CNBM does not specify or warrant frame clips or clamps using frame clips not provided or clamps module not provided is also possible when they are designed for PV modules and with minimum dimensions on the sides of the module in accordance with the instructions and drawings provided If using frame clips or clamps the modules should be fixed rigidly and there shall be no damage to the modules by deforming mounting structure against design load CNBM does not specify or warrant frame clips The CNBM module warranty may be void if customer selected frame clips which are improper or inadequate with respect to the module properties including strength or material or installation Note that if metal clips are used there must be a path to ground from the clips for instance using star washers in the clip hardware set Please review the descriptions and drawings carefully not mounting the modules according to one of these methods may void your warranty These mounting methods are designed to allow module loading of 2400pa Page 18 of 20 Everything For CMAX CNBM LAG bua acpay atiam O O c D CNBM INTERNATIONAL CORPORATION sketch map Page 19 of 2

Download Pdf Manuals

image

Related Search

Installation installation installation assistant installation directory installation folder installation art installation media installation wizard installation file installation manager installation assistant windows 11 installation status report installation made easy installation floater installation of mini split air conditioner installation definition installation status installation guide installation synonym installation instructions installation manual installation has failed discord installation failed installation wizard 2 installation whatsapp installation and commissioning

Related Contents

UM10856 User manual for dI2C demo board  what is latch?  BMW Motorrad zmo GPS Receiver User Manual  おしゃべり熱中症計( 風邪ひき指数・温湿度計付き) 新発売  Caméscope numérique HD  GE USER MANUAL ORIGINAL 1 - CPI Security  Télécommande sans fil avec écran LV-W1 Manuel d  Manual - TRS RenTelco  

Copyright © All rights reserved.
Failed to retrieve file