1. 45612 Z2W3003 3 45613 ZW3003 amp ZW2002 Wireless Lighting Control On Off Dim Dimmer Switch exp Z Wave Certified Wireless Lighting Control Introduction Thank you for your purchase of a GE Z Wave control device Z Wave technology is designed to automate lighting home control and provide easy remote operation of all your Z Wave enabled devices The GE Z Wave product family includes a variety of devices to control lighting in your home It is up to you whether you want to control one room or your entire house and whether you want to do it all now or start with one room and add more over time This dimmer is one component of a Z Wave control system and is designed to work with all other Z Wave enabled devices in a home control network It will also act as a wireless repeater to insure that commands intended for another device in the network are received thereby extending the range of the wireless controller Z Wave devices of other types and brands can be added to the system and will also act as range extenders if they support this function of repeating the signal received to other nodes in the system ACAUTION This device is intended for installation in accordance with the National Electric Code and local regulations in the United States or the Canadian Electrical Code and local regulations in Canada If you are unsure or uncomfortable about performing this installation consult a quali
2. TRAVELER The Traveler terminal is only used for 3 way or 4 way wiring and should remain insulated if the 45612 is being installed in a 2 way system one switch amp one load Match these screw terminals to the wires connected to the existing switch Do Not remove the tape over the terminal if you are not using the traveler connection 6 Disconnect the wires from the existing switch 7 Connect the green or bare copper ground wire to the GROUND terminal 8 Connect the black wire that goes to the light to the terminal marked LOAD 9 Connect the black wire that comes from the electrical service panel Hot to the terminal marked LINE Note UL specifies that the tightening torque for the screws is 14Kgf cm 10 OPTIONAL for 3 or 4 way control Connect the Traveler wire usually Red to the screw terminal marked TRAVELER The other end of this Traveler wire connects to the TRAVELER screw terminal on the 45610 Auxiliary Switch See the following section for information about wiring the 45610 Auxiliary Switch 1 Insert Z Wave Switch into the switch box being careful not to pinch or crush wires 12 Secure the switch to the box using the supplied screws 3 Mount the wall plate 4 Reapply power to the circuit at fuse box or circuit breaker and test the system Optional for 3 or 4 Way Control The 45610 requires the following 3 wiring connections a The Traveler wire This is used to send voltage signals to the primary Z
3. Wave switch The signals tell the Z wave switch what action to perform b Ground c Neutral 2 DO NOT connect the 45610 auxiliary switch to the home s black Hot Line wire Observe Important Wiring Information Important This switch is rated for and intended to only be used with copper wire The home s electrical wires may be attached to the screw terminals or inserted into the holes in the back of the switch enclosure and clamped in place by tightening the screw terminals Always follow the recommended wire strip lengths when making wiring connections Wire strip length e For attachment to screw terminals Strip insulation 5 8 max 14 AWG wire e For attachment using the enclosure s holes Strip insulation 5 8 max 14 AWG wire You should now be able to use the rocker to manually turn On Off or adjust the brightness of the connected load Use your primary controller to include the switch in the home control network after the switch is wired as shown in the above diagram It can then be added to groups and or lighting scenes and managed remotely to control the On Off Dim status of the connected lighting Air Gap Switch During normal operation there is a small amount of power passing through the switch to the load even when the switch is turned off The 45612 has an air gap switch on the lower left side see diagram for location to completely disconnect power to the load Pull the air gap switch O
4. to understand how the circuit you wish to upgrade to Z Wave control is wired Below is a description of a typical 3 way circuit One of the ways to wire a two switch one load circuit is to route the incoming power through the first switch then to the second switch and then to the load Although very common and by no means a standard it is the easiest to convert to Z Wave control With this type of circuit Switch 1 is replaced by the Z Wave auxiliary switch and Switch 2 is replaced with the primary Z Wave switch The auxiliary switch does not actually control the power instead it sends a momentary voltage signal through the traveler wire to the primary switch which in turn controls the power to the load Typical 3 way circuit L White Switch 1 Switch 2 Black Black Black Colored NOT GREEN Wrong Z Wave switch position for typical 3 way circuit Black Line Hot White White Neutral Correct Z Wave switch position for typical 3 way circuit Black Z Wave Primary Other Z Wave Auxiliary White Please consult an electrician if you have trouble identifying the type of wiring circuit you wish to convert or if you do not feel confident in your ability to convert the circuit to Z Wave control INSTALLATION This dimmer switch may be used in new installations or to replace an existing wall switch It may be u
5. you must still tap press amp release the bottom of the rocker to turn the power OFF e When OFF pressing and holding the bottom of the rocker will cause the lighting to go to the minimum dim level Program your Light Switch Include or exclude the switch to from the Z Wave home control network e Refer to the instructions for your primary controller to access the network setup function and include or exclude devices eWhen prompted by your primary controller tap the top or bottom of the rocker eThe primary controller should indicate that the action was successful If the controller indicates the action was unsuccessful please repeat the procedure Once the switch is part of the network the same basic procedure is used to add the switch to groups amp scenes or change advanced functions Refer to the primary controller s instructions for details Note After a power failure the 45612 dimmer switch will default to OFF LED Indicator The LED will be lit when the connected lighting is OFF This is the factory default setting and can be changed if your primary controller supports the node configuration function see Advanced Operation below ADVANCED OPERATION The following Advanced Operation parameters require that you have an advanced controller like the GE model 45601 LCD remote Advanced remotes from other manufacturers may also be able to change these settings however basic remotes do not have this capability
6. All On All Off Depending upon your primary controller the 45612 switch can be set to respond to ALL ON and ALL OFF commands in up to four different ways Some controllers may not be able to change the response from its default setting Please refer to your controller s instructions for information on whether or not it supports the configuration function and if so how to change this setting 1 The four possible responses are 2 It will respond to ALL ON and the ALL OFF command default 3 It willnot respond to ALL ON or ALL OFF commands 4 It will respond to the ALL OFF command but will not respond to the ALL ON command 5 It will respond to the ALL ON command but will not respond to the ALL OFF command LED When shipped from the factory the LED is set to turn ON when the connected light is turned OFF This allows the LED to indicate the switch s location in a dark room To make the LED turn ON when the light is turned ON change parameter 3 s value to 1 e Parameter No 3 e Length 1 Byte e Valid Values 0 or 1 default 0 Invert Switch If the switch is accidentally installed upside down with On at the bottom and Off at the top the default On Off rocker settings can be reversed by changing parameter 4 s value to 1 e Parameter No 4 e Length 1 Byte e Valid Values 0 or 1 default 0 Dim Rate Adjustments Both the number of steps or levels that the dimmer will change and the timin
7. UT to disconnect the power while replacing light bulbs and push it all the way back in for normal operation The air gap switch must be all the way in for the switch to function and control the lighting Key Features e Remote On Off Brightness control via the Z Wave controller network e Manual On Off Brightness control with the front panel rocker e Compatible with 2 3 or 4 way wiring configurations e LED indicates switch location in a dark room BASIC OPERATION Remote Control GE Z Wave remotes provide control of an Individual device Groups of devices and Scenes Other brands of Z Wave Certified remotes may not offer as much flexibility in how you can set up your lighting control network Please refer to your remote control s instructions for details on its capabilities and instructions for adding and controlling devices Manual Control The 45612 dimmer switch allows the user to Turn ON OFF and control the brightness level of the connected lighting e To turn the connected lighting ON Tap the top of the rocker e To turn the connected lighting OFF Tap the bottom of the rocker e To brighten the connected lighting Press and hold the top of the rocker release when desired level is achieved e To dim the connected lighting Press and hold the bottom of the rocker release when desired level is achieved Please note pressing and holding the rocker until the light intensity is at the minimum setting does not turn the power OFF
8. al Frequency 908 42 MHz Maximum Loads 600W incandescent Range Up to 100 feet line of sight between the Wireless Controller and the closest Z Wave receiver module Operating Temperature Range 32 104 F 0 40 C For indoor use only Specifications subject to change without notice due to continuing product improvement Z Wave is a registered US trademark of Sigma Designs 2010 JASCO Products Company is a registered trademark of General Electric Company and is used under license to Jasco Products Company LLC 10 E Memorial Rd Oklahoma City Oklahoma 73114 Made in China Hecho en China All brand names shown are trademarks of their respective owners Todas las marcas que aparecen aqui son marcas registradas de sus respectivos duefios 45612 45613 rev 1 21 11
9. e devices controlling appliances should be removed rom All control setting Instructions on how to do this are included in the manual for your GE remote Do Not include Z Wave devices in Groups or Scenes if they control appliances Do Not use Z Wave devices to control electric heaters or any other appliances which may present a hazardous condition due to unattended or unintentional or automatic power on control Double check programs for accuracy before using them Wireless Range This device complies with the Z Wave standard of open dir line of sight transmission distances of 65 feet Actual performance in a home depends on the number of walls between the remote controller and the destination device the type of construction and the number of Z Wave enabled devices installed in the control network Every Z Wave enabled device acts as a signal repeater and multiple devices result in more possible transmission routes which helps eliminate RF dead spots Things to consider regarding RF range e Each wall or obstacle i e refrigerator big screen TV etc between the remote or Z Wave device and the destination device will reduce the maximum range by approximately 25 30 e Brick tile or concrete walls block more of the RF signal than walls made of wooden studs and plasterboard drywall e Wall mounted Z Wave devices installed in metal junction boxes may suffer a significant loss of range approximately 20 since th
10. e metal box blocks a large part of the RF signal Effects of Home Construction on Wireless Range Between Z Wave Enabled Devices Note The distances shown in the table below are typical examples Actual performance in your home will vary From the Remote or repeating Z Wave module to destination device Type of Construction Wood Frame Brick Tile or w Drywall Concrete Plastic Metal Plastic Metal J Boxes J Boxes J Boxes J Boxes 0 100 80 100 80 Number 7 i P of Walls or 1 70 56 60 48 Obstacles 2 49 39 36 29 3 34 27 21 17 For Plug in Modules or In Wall Devices Installed Plastic Junction Boxes Line of Sight no obstructions Please Note Z Wave home control networks are designed to work properly alongside 802 11 wireless computer networks Bluetooth and 2 4GHz 5 8GHz or DECT devices Some baby cams wireless video devices and older cordless phones using the 900MHz frequency range may cause interference and limit Z Wave functionality Many 900MHz products have a switch to select channel A or B You may find that one of these channels will cause less interference than the other IMPORTANT NOTE ABOUT 3 WAY CIRCUITS The term 3 way circuit refers to a circuit with two switches and one load light like you find at the top and bottom of a stairway There are many ways to physically wire a 3 way circuit and it is important
11. fied electrician This switch is designed for use only with permanently installed incandescent fixtures Do not use it to control fluorescent lighting transformer supplied lighting appliances or receptacles The incandescent lighting controlled by this dimmer switch must not exceed 600 watts NOT FOR USE WITH MEDICAL OR LIFE SUPPORT EQUIPMENT Z Wave enabled devices should never be used to supply power to or control the On Off status of medical and or life support equipment There are no user serviceable parts in this unit Dimmer switch LED light Air gap switch WARNING RISK OF FIRE RISK OF ELECTRICAL SHOCK RISK OF BURNS Controlling Appliances Exercise extreme caution when using Z Wave devices to control appliances Operation of the Z Wave device may be in a different room than the controlled appliance also an unintentional activation may occur if the wrong button on the remote is pressed Z Wave devices may automatically be powered on due to timed event programming Depending upon the appliance these unattended or unintentional operations could possibly result in a hazardous condition For these reasons we recommend the following 1 Assign Z Wave controlled appliances to device numbers 10 18 onthe GE remote The likelihood of unintentionally urning on the appliance will be reduced significantly because the Shift button will need to be pressed before pressing device numbers 10 18 Z Wav
12. g of the steps can be modified to suit personal preferences The timing of the steps can be adjusted in 10 millisecond intervals 1 When Receiving a Z Wave Dim Command e Parameter 7 number of steps or levels Parameter 8 timing of the steps e Length 1 Byte e Valid Values Parameter 7 default 1 Valid Values 1 99 Parameter 8 default 3 Valid Values 1 255 2 Manual Control Dimming pressing the Dimmer s rocker e Parameter 9 number of steps or levels e Parameter 10 timing of the steps e Length 1 Byte e Valid Values Parameter 9 default 1 Valid Values 1 99 Parameter 10 default 3 Valid Values 1 255 3 When Receiving an All On or All Off Command e Parameter 11 number of steps or levels e Parameter 12 timing of the steps e Length 1 Byte e Valid Values Parameter 11 default 1 Valid Values 1 99 Parameter 12 default 3 Valid Values 1 255 Ignore Start Level When Receiving Dim Commands Please note Every Dim command includes a start level embedded in it The 45612 can be set to ignore the start level that is part of the dim command Setting parameter 5 to a value of 0 will cause the 45612 to dim or brighten from the start level embedded in the command e Parameter No 5 e Length 1 Byte e Valid Values 0 or 1 default 1 Restoring Factory Defaults All Configuration Parameters can all be restored to their factory default settings by using your master controller to delete rese
13. not installed and used in accordance with the instruction may cause harmful interference to radio communication However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Operation is subject to the following two conditions This device may not cause interference This device must accept any interference including interference that may cause undesired operation of the device Important Note To comply with the FCC RF exposure compliance requirements no change to the antenna or the device is permitted Any change to the antenna or the device could result in the device exceeding the RF exposure requirements and void user s authority to operate the device Compliance with IC Rules and Regulations IC 6924A 45606R2 Jasco Products Company Model 45612 45613 ZW3003 This Class B digital device complies with Canadian ICES 003 SPECIFICATIONS Power 120 VAC 60 Hz Sign
14. s may be installed in dual or triple gang boxes and if necessary one or both sides of the heat sink may be removed by bending it at the score lines There is a corresponding reduction in the switch s load rating when ganged DO NOT exceed the following loads Dimmer Rating Number of Dimmers Heat Sink 600W One switch in a Single Gang Box Full 500W Two switches in a Double Gang Box One side removed 400W Three switches in a Triple Gang Box Both sides removed Traveler dawcove 3003209 O Traveler Q Dimmers Switch F i A inated moangescont oat AN 120 Volts AC 60Hz Max 600W Incandescent Load Indoor Use Only Groun JEO FCC 1O vazstoene Alniko br ri Load Line JASCO Products Oklahoma City OK o a ce Oe o s Black Load AWARNING Turn OFF the power to the branch circuit at the circuit breaker in your electrical service panel Ensure power is OFF before you install this device All wiring connections must be made with the POWER OFF to avoid personal injury and or damage to the switch 1 Shut off power to the circuit at fuse box or 15A circuit breaker 2 Remove wall plate Warning Verify power is OFF to switch box before continuing 3 Remove the switch mounting screws 4 Carefully remove the switch from the switch box DO NOT disconnect the wires 5 There are four screw terminals on the 45612 switch these are marked LINE Hot LOAD GROUND and
15. sed by itself for 2 way control one switch amp one load with one 45610 Auxiliary Switch for 3 way control two switches amp one load or with two 45610 Auxiliary switches for 4 way control three switches amp one load When used by itself for 2 way control please make sure that the screw terminal for the traveler wire is insulated Do Not Remove the tape over the terminal if you are not using the traveler connection Single Switch Wiring Schematic White Neutral Black Load Wave 45612 Green Ground Black Line Hot 3 Way Wiring Schematic using one 45612 and one 45610 White Neutral Traveler Colored Not Green ea 2 Wave 45610 Black Load Zz Wave 45612 Green Ground Black Line Hot 4 Way Wiring Schematic using one 45612 and two 45610 s Z Wave 45610 White Neutral Green Ground Traveler Colored Not Green Cor Traveler Colored Not Green ey Z Wave 45610 Green Ground Z Wave 45612 Black Line Hot Black Load Single Dual and Triple Gang Boxes The metal plate surrounding the switch assembly is a heat sink The maximum load rating 600W is provided when installed in a single gang box with the full heat sink Multiple 45612 dimmer switche
16. t the device WARRANTY JASCO Products warrants this product to be free from manufacturing defects for a period of two years from the original date of consumer purchase This warranty is limited to the repair or replacement of this product only and does not extend to consequential or incidental damage to other products that may be used with this product This warranty is in lieu of all other warranties expressed or implied Some states do not allow limitations on how long an implied warranty lasts or permit the exclusion or limitation of incidental or consequential damage so the above limitations may not apply to you This warranty gives you specific rights and you may also have other rights which vary from state to state Please contact Customer Service at 800 654 8483 option 4 between 7 30AM 5 00PM CST or via our website www jascoproducts com if the unit should prove defective within the warranty period JASCO Products Company Building B 10 E Memorial Rd Oklahoma City OK 73114 Fi U2Z45606R2 The Federal Communication Commission Radio Frequency Interference Statement includes the following paragraph The equipment has been tested and found to comply with the limits for a Class B Digital Device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment uses generates and can radiate radio frequency energy and if