1. eer Ge Barli i rene E Precipico Posten MonBoring EIERE WEE i Pa Ethernet UDP w Communications f mmVu Engine Status Baseline 1 2 amp 3 g gt ES Reference Monitored Station mm Vu E n g ne svs 9 10 Epoch 223690 000 sec DDC TOO Passed SVs 9 Passed Svs 9 Figure 1 mmVu 3 0 system configuration Gemini Navsoft Technologies Inc 02013 All rights reserved GEMINI Navsoft Technologies Inc mmVu Client Demo User s Manual v3 0 2 3 System Field Setup A typical field setup of mmVu 3 0 is illustrated in Figure 2 Gee Local Area Network Project Site Monitored Station G3100 Station G8100 Wired WVirelass Ethernat Vilde Area Network Wired Wireless Ethernet red Ethernet Reference Station GANT Position Salver 65100 P5100 Figure 2 mmVu 3 0 field setup Gemini Navsoft Technologies Inc 02013 All rights reserved mmVu Client Demo User s Manual v3 0 GEMINI Navsoft Technologies Inc 3 mmVu Client Layout The mmvVu Client is an independent sub system of mmVu 3 0 which has been designed for plotting Baseline solutions As plotting resources can consume CPU excessively users are recommended to install the mmVu Client on their own computers rather than the Local Server PS100 Users can use the mmVu Client as a graphic viewer of the Baseline solutions Figure 3 For System Int
2. mmVu we Client Demo Precision Position Monitoring mmVu Client Demo User s Manual v3 0 GEMINI Navsoft Technologies Inc GEMINI Navsoft Technologies Inc Knowledge Park Suite 130 40 Crowther Lane Fredericton NB Canada E3C 0J1 www gemini navsoft com Gemini Navsoft Technologies Inc 02013 All rights reserved 2 GEMINI Navsoft Technologies Inc mmVu Client Demo User s Manual v3 0 Contents MTOM EEE EE EE 4 DET 5 DNV Na 5 SEET 6 TNS NNN 7 NTN 8 3 1 Ethernet TCP IP Connection i 9 32 ICP Data NNN 9 3 3 VIEWING Archive Data EE 10 SKE eo FOO EE 11 EE rana ir ara tri 11 TETEN NNN 11 SEN NG E 12 JR SSG nino 13 EE ON e RE EEE 14 TENNE 15 Gemini Navsoft Technologies Inc 02013 All rights reserved 3 GEMINI Navsoft Technologies Inc mmvVu Client Demo User s Manual v3 0 1 Forward Congratulations on purchasing a Gemini Navsoft Technologies GNT product Gemini technology is built upon years of research and developments that have allowed us to deliver the highest level of GNSS positioning performance This manual describes the operation of mmVu 3 0 Client software so that you can configure and deploy your own monitoring system No software can account for a prerequisite understanding of GNSS and the conditions that optimize GNSS performance Gemini provides supporting manuals documentation and training services to help you to gain this understanding This com
3. 07 99 06 CE 93 4C FD FD 3F Figure 5 Data packet received by the mmVu Client 3 3 Viewing Archive Data The mmVu Client allows the import of GNT format baseline solution files This allows the user to visualize an archive of data that can be appended and updated by the TCP data stream NOTE The user should add archived data BEFORE activating the TCP Data Stream from the Server Clicking the Read File button on the viewer interface brings up a browser menu see Figure 6 SAC Suiten File Ea Change Folder C YGemini Navsoft Technologies mmVu LabTime Projects DDCO2 H j app ki i A k f kA d d d d d d 2 2 d d d p 7 3 DDCO2 12072000 5o DDC02_ 12072100 501 DDC02_12072200 501 DK 120723500 501 DDC02_12072400 501 DDC02_12072500 501 DDC02_12072600 501 DDC02_12072700 501 DK IM 12072800 501 DNK I 12072900 501 DDC02 12073000 501 DK 12073100 501 IN NI 17080100 sal Cs bh fo fo bh bh fo fo fo fo fo fk Feb FI Ka GEI 2 BECH 2 L E 2 r 2 RK 2 DD002_12072000 501 DDC002_12072100 501 DDC02_12072200 501 DD002_12072300 501 DD002_12072400 501 DD002_12072500 501 DDC02_12072600 501 DD002_12072700 501 DK 12072800 501 DON 12072900 50l DDODZ 12073000 501 DD002_120735100 501 Non 17080100 sal All OK Cancel Figure 6 Select GNT File Format Solution Files for visualization Gemini Navsoft Technologies Inc 2013 All
4. rights reserved 10 GEMINI Navsoft Technologies Inc mmvVu Client Demo User s Manual v3 0 Simply direct the browser to the appropriate folder location and add the desired solution files For convenience the user can import solution files for several filters and baselines from the same folder Different filter types for each baseline will loaded automatically Each baseline will be imported individually 3 4 Graphic Tools The mmVu Client provides a set of graphic tools to plot the Baseline solutions It also allows users to analyze the charts visually 3 4 1 Baselines Once the mmVu Client receives the data packet from the mmVu Server it starts to decode the packet and lists up the Baselines in the packets Figure 7 Select one Baseline to plot its solutions Users can switch to another Baseline any time Plot Baseline Solutions Figure 7 List of Baselines Users should be aware of that baseline switching action can cause excessive CPU consumption This can stop the normal operation of the mmVu Client It is recommended that users click the Pause button first and then switch another baseline especially when a number of solutions have been already plotted 3 4 2 Filter Type As seen in Gemini Navsoft Technologies Inc 2013 All rights reserved 11 GEMINI Navsoft Technologies Inc mmvVu Client Demo User s Manual v3 0 Figure 8 users can check the TDD and DDC filter s to plot the Base
5. bination of mmVu 3 0 processing technology and system deployment knowledge will help you to maximize the return on your purchase Gemini Navsoft Technologies Inc 2013 All rights reserved 4 GEMINI Navsoft Technologies Inc mmvVu Client Demo User s Manual v3 0 2 Description 2 1 Overview The mmVu Client is an independent sub system of mmVu 3 0 which has been designed for plotting mmVu RT e g mmVu Solver mmVu Server and mmVu Synergizer real time Baseline solutions The example mmVu Client is part of the mmVu 3 0 software package and this manual includes instructions for system integrators who wants to use the results of the mmVu RT in their own software Gemini Navsoft Technologies Inc 2013 All rights reserved 5 GEMINI mmVu Client Demo User s Manual v3 0 Navsoft Technologies Inc 2 2 System Configuration mmVu 3 0 software system is comprised of three sub systems including mmVu Server mmVu Engine and mmVu Client As illustrated in Figure 1 each mmVu sub system is connected through Ethernet TCP IP and UDP communications As each mmVu sub system runs independently mmVu 3 0 can be configured on either a single hardware platform or multiple server computers According to users requirements the system configuration of mmVu 3 0 can be optimized di N GNSS Stations iS s a Ethernet TCP IP Communications mmVu Server mmVu Client
6. d unless the Update button is clicked 3 4 4 Y Axis Control V Axis Control Control Mode Ce Automatic Settings Maximum Value Figure 11 Y Axis Control panel Gemini Navsoft Technologies Inc 02013 All rights reserved 13 GEMINI Navsoft Technologies Inc mmvVu Client Demo User s Manual v3 0 Y Axis Control allows users to manually adjust the plotting margin of y axis By default the mmVu Client decides the plotting margin of y axis automatically To activate Y Axis Control move the mouse on a plotting panel e g East North or Up press the Ctrl key and at the same time click the left button of the mouse This combination of the key actions will pop up the Y Axis Control panel as illustrated in Figure 11 3 4 5 Type of Plot The mmVu Client has capabilities to plot the Baseline solutions in Point or Line feature Figure 12 Figure 13 and Figure 14 Users can switch to another plot feature any time Figure 12 Type of plot Figure 14 Line plot Gemini Navsoft Technologies Inc 2013 All rights reserved 14 GEMINI Navsoft Technologies Inc mmVu Client Demo User s Manual v3 0 3 4 6 Plotting Control The mmVu Client provides users with a set of control buttons Figure 15 to control the plot being displayed Refresh Pause Resume Figure 15 Plot control buttons Refresh Click this button to refresh the entire plots A warning
7. egrators who want to feed the Baseline solutions into their own systems the mmVu Client demonstrates how this can be done see Error Reference source not found and Error Reference source not found The mmVu Server allows a limited number of Clients to log in the GNT s Local Server 2 mmVu Client Demo Version 1 1 Gemini Navsoft Technologies Inc mee Ethernet TCP IP Connection Baseline 1 2 192 168 002 Peer IP Address Peer Port 8815 Local Port 61616 Local IP Address 197 168 2 15 User ID admin Connect Disconnect Read File 315165 000 sec TCP Data Streaming la7 AE 54 00 00 96 00 03 02 03 07 DE 06 oo 00 00 00 00 00 74 3C 13 41 CC 77 26 D4 D4 79 96 40 67 89 41 D7 EC 75 A4 CO 87 AG 16 03 DD 6D 12 CO E4 64 BC E3 72 Filter Type vw Ti kW DDC1 Iv ToD M ppc h T M DDC3 X Axis Control Panning Window Size 72 hour 7 Plotting Frequency 60 sed Update Figure 3 mmVu Client layout Gemini Navsoft Technologies Inc 02013 All rights reserved 8 GEMINI Navsoft Technologies Inc 3 1 Ethernet TCP IP Connection mmVu Client Demo User s Manual v3 0 The mmVu Client communicates with the mmVu Server through Ethernet TCP IP connection as illustrated in Figure 4 Once the connection is established see Error Reference source not found the mmVu Server streams Basel
8. ine solutions to the mmVu Client Ethernet TCP IP Connection Peer IP Address Peer Port Local Port Local IP Address User ID 192 168 123 108 8815 admin User Password Ga Connect Disconnect Figure 4 Ethernet TCP IP connection panel Peer IP Address Unique Ethernet IP address of the mmVu Server Peer Port Number Port number of the mmVu Server for TCP connection Valid range 8000 8999 See mmVu Server Manual v2 0 section 4 2 1 Local Port Number Port number of the user s computer for TCP connection Valid range 0 65535 Local IP Address Unique Ethernet IP address of the user s computer It will be automatically detected by the mmVu Client User ID Password User ID and Password registered for the mmVu Server 3 2 TCP Data Streaming TCP Data Streaming panel displays a small part of the data packets received from the mmVu Server Figure 5 The Baseline solutions processed by the mmVu Engine are encoded in Gemini Navsoft Technologies Inc 2013 All rights reserved 9 Navsoft Technologies Inc GEMINI mmVu Client Demo User s Manual v3 0 packets see Error Reference source not found before the mmVu Server streams the packets to the mmVu Client TCP Data Streaming 321755 000 sec 47 4E 54 00 00 00 F E3 SC 19 CA 92 OG 01 02 05 OG 00 00 Gc A3 13 dl 33 CO 4A DI SE Ba 60 4E 3D Bl CA SF 35 1F GF 99 27
9. line solutions corresponding to the filter s Uncheck the filter s to remove the plot corresponding to the filter s Filter Type i TOD i DDC1 W ToD W ppc iw TODS i DDC3 Figure 8 TDD and DDC filters 3 4 3 X Axis Control X Axis Control allows users to adjust the size of plot window and the frequency of plotting Figure 9 A maximum number of plotting points is implemented to ensure that plotting resources do not cause excessive CPU consumption X Axis Control Information Figure 10 is shown whenever this maximum is exceeded Adjust the display parameters to comply with the number of plotting point s constraint X Axis Control Panning Window Size 24 hour Plotting Frequency 5 sec Update Figure 9 X Axis Control panel Panning Window Size The plot will be automatically panned forward when the size of the plot displayed exceeds this input Plotting Frequency Plotting time interval in seconds Update Click this button to make an effect of the inputs in plotting This button will show the X Axis Control Information as illustrated in Figure 10 Gemini Navsoft Technologies Inc 02013 All rights reserved 12 GEMINI Navsoft Technologies Inc mmvVu Client Demo User s Manual v3 0 X Asds Control Information Plotting max Window Size Frequency seconds Figure 10 X Axis Control Information Users should be aware of that all user inputs in the X Axis Control will not be update
10. message will be displayed Figure 16 Pause Click this button to pause plotting This action does not affect the process of mmVu Client The mmVu Client continues its background process with no interruption Resume Click this button to resume plotting The mmVu Client will resume plotting the Baselines solutions mmvuChent Refreshing all data could take long time Are you sure for this Ves No Figure 16 Plot Refresh warning message Users should be aware of that the Refresh button can cause excessive CPU consumption This can stop the normal operation of the mmVu Client It is recommended that users do not click the Refresh button often especially when a number of solutions have been already plotted Gemini Navsoft Technologies Inc 2013 All rights reserved 15 GEMINI Navsoft Technologies Inc mmVu Client Demo User s Manual v3 0 The mmVu Client also provides users with a set of special key mouse strokes to control the plot being displayed Zoon In Click and hold the left button of the mouse drag forward i e move the mouse to the right direction and then release the left button to zoon in an area of interest Zoon Out Click and hold the left button of the mouse drag backward i e move the mouse to the left direction and then release the left button to zoon out Panning Click and hold the right button of the mouse and drag forward or backward to pan the plo
11. t left or right direction Users should be aware of that zoom or pan action can cause excessive CPU consumption This can stop the normal operation of the mmVu Client It is recommended that users click the Pause button first and then activate the plot controls especially when a number of solutions have been already plotted Gemini Navsoft Technologies Inc 2013 All rights reserved 16 GEMINI Navsoft Technologies Inc mmVu Client Demo User s Manual v3 0 Document Change Record Issue Reasons for Revision v1 0 Separating Sever and Client Manuals v2 0 New version released v2 1 Baseline solution data format has been changed see Table 4 v2 1 rev2 Revised version released v2 2 2013 07 24 Added section 3 3 Viewing Archive Data v3 0 2015 02 09 GNT data format and communication protocol removed Gemini Navsoft Technologies Inc 2013 All rights reserved 17

Download Pdf Manuals