        APEX PROFILER USER MANUAL
         Contents
1.     A PTS sample is collected at the  beginning of the Profile phase at the achieved profile depth  Subsequent PTS samples are  collected during profile ascent per the programmed depth table     15 of 40    Profile and Profile Cycle Schematics    Down Time    Surface    Park Depth    Profile Depth       Time             Deep Profile every cycle    Deep Profile every third cycle       Time        gt     16 of 40    Vil  Deep Profile First  DPF     Independent of the Park and Profile cycle length  the first profile is always a Deep Profile that  begins at the Profile Depth  This means the float returns a CTD profile relatively soon  typically  less than a day  after the float is deployed  This feature supports comparison of the initial float  profile with a conventional CTD cast from the ship     The first descent begins at the end of the Mission Prelude  A schematic representation of DPF  with a Park and Profile parameter N   2 is shown below     N   2 and Deep Profile First  DPF   Deep Profile on first cycle and every second cycle       Time           gt     Note  For maximum battery life in ARGO applications  Teledyne Webb Research recommends  use of PD  gt  one  with park depth  lt  1500 db     17 of 40    Vill  ARGOS Data    A  SERVICE ARGOS Parameters    Each float operator must specify various options to Service ARGOS  These choices depend on  how the user plans to receive and process data  Typical Service ARGOS Parameters are     e Standard location   e Processing  Type
2.    Print this menu   z Display the SBE41 calibration coefficients   Sf Display SBE41 firmware revision   Sm Measure power consumption by SBE41   Sn Display SBE41 serial number   Sp Get SBE41 P   Ss Get SBE41 P T amp S   St Get SBE41 P  amp  T  low power      Float Vitals Menu  F        Print this menu    Fb Maximum air bladder pressure   1 254   counts   FF Piston full extension   1 254   counts    Fn Display float serial number    Fs Storage Piston Position   1 254   counts    Fv OK vacuum threshold   1 254   counts     37 of 40    Appendix F  Returning APEX floats for factory repair or refurbishment    Contact Teledyne Webb Research before returning APEX floats for repair or refurbishment  All  returns from outside USA  please specify our import broker     Consignee  Teledyne Webb Research  82 Technology Park Drive  East Falmouth  MA 02536    Notify  DHL Danzas Freight Forwarding Agents  Attn  Ellis Hall  Import Broker  Phone  617  886 6665  FAX  617  242 1470  500 Rutherford Avenue  Charlestown  MA 02129    Note on shipping documents  US MADE GOODS    CAUTION  If the float was recovered from the ocean  it may contain water  which presents a  safety hazard due to possible chemical reaction of batteries in water  The reaction may generate  explosive gases  see  Alkaline Battery Warning  at the beginning of this manual   In this case   be sure to remove the seal plug to ventilate the instrument before shipping  Do this is a well  ventilated location and do not lean over the s
3.    S N 8413 is encoded as 0x20DD    Seabird SBE41 F W Revision  encoded as a hex integer after  multiplication by 100  e g   F W 2 6     260     0x0104   Current UNIT epoch  GMT  of Apf9a RTC  little endian order   Minutes past midnight when down time will expire  If ToD  feature disabled  bytes   Oxfffe    Debugging Verbosity for generating engineering log entries   Not used  OxFF     20 of 40    Test Message 1   Status Word   16 bits    Bit   0x0001  0x0002  0x0004  0x0008  0x0010  0x0020  0x0040  0x0080  0x0100  0x0200  0x0400  0x0800  0x 1000  0x2000  0x4000  0x8000    Mnemonic    DeepProfile  Shallow WaterTrap  Obs25Min  PistonFullExt  AscentTimeOut  TestMsg  PreludeMsg  PActMsg  BadSeqPnt  Sbe41PFail  Sbe41PtFail  Sbe41PtsFail  Sbe41 Unreliable  AirSysBypass  WatchDogAlarm  PrfldOverFlow    Description    Current profile is a Deep Profile   Shallow water trap detected   Sample time out  25 minutes  expired   Piston fully extended before surface detected   Ascent time out expired   Current message is a test message   Current messaged transmitted during Mission Prelude  Current message is a Pressure Activation test message  Invalid sequence point detected   SBE41 pressure measurement exception   SBE41 pressure temperature measurement exception   SBE41 pressure temperature salinity measurement exception  SBE41 pressure measurement unreliable   Air inflation system bypassed  excessive energy consumption   Wake up by watchdog alarm   8 bit profile counter overflowed  255    
4.    ey TELEDYNE WEBB RESEARCH    A Teledyne Instruments  Inc  Company    82 Technology Park Drive   E  Falmouth  Massachusetts 02536  Phone  508 548 2077   Fax  508 540 1686   Email   apexsupport webbresearch com    APEX PROFILER USER MANUAL    Applies to Serial Numbers  Revision Date  04 02 10  5098  5099 Customer Name  CSIRO  Job Number  1762 B  Firmware Revision APF9A F W 062608  Features   APF9A Controller  Flash Depth Table 65 Park and Profile with 20  or 28 bit ARGOS ID  Profile Observation Deep Profile First  DPF     Pressure Activation  optional        I  Alkaline Battery Warning    II   III   IV     AS O a    V  Deploying the Float    VI   A   B    VII    VIII     AS OF    F     Appendix A  Surface Arrival Time and Total Surface Time  Appendix B  Argos ID formats  28 bit and 20 bit  Appendix C  Storage conditions  Appendix D  Connecting a Terminal  Appendix E  APF9A Command Summary       APF9 Operations Warning for APF8 Operators       Maximum Operating Pressure       Evaluating the Float and Starting the Mission       Manual Deployment with the Reset Tool   Pressure Activation Deployment   Mission Activation and Mission Prelude ARGOS Transmissions  Mission Activation and Operator Float Function Check    Notes and Caveats       Park and Profile       Profile Ascent Timing  Profile and Profile Cycle Schematics    Deep Profile First  DPF        ARGOS Data       FAIA A R W    13  14  15  15  16  17  18       SERVICE ARGOS Parameters   Test Messages   28 bit ARGOS ID   Mi
5.  0     21 of 40    C  Data Messages   28 bit ARGOS ID    The number of data messages depends on the number of measurements made during the profile   The formats of the data messages are shown in the tables below  Data Message 1 contains float   profile  and engineering data     Data Message 1   28 bit ARGOS ID    Byte s   1    NWN    8 9  10 11  12   13   14   15   16  17 18  19   20  21   22   23   24   25    26  27  28  29  30   31    32    Mnemonic Description    CRC  MSG    BLK    FLT  PRF  LEN  STATUS  SP  VAC  ABP  SPP  PPP2  PPP  SBE41  PMT  VQ   IQ  VSBE  ISBE  VHPP    IHPP  VAP  IAP  PAP    VSAP    Message CRC   Message ID   each data message block is comprised of multiple  messages  this will be a 1 for Data Message 1   Message block ID   increments with each transmitted message block  and wraps at OxFF   Float ID  apf9a controller serial number    Profile number  wraps to 0 from 255    Number of TSP samples in this message block   Same as the Test Message 1 Status word  see above    Surface pressure at end of Up Time  centibars    Internal vacuum at end of Park phase  counts    Air bladder pressure at end of each ARGOS transmission  counts   Piston position when surface detected  counts    Piston position at end of Park phase  counts    Piston position at end of last Deep descent phase  counts    SBE41 status word   16 bits  see below   Cumulative piston on time during ascent  seconds    Battery voltage at end of Park phase  counts    Battery current at end of Park
6.  232 communications cable should be  connected to the COM port of a PC  Runa  communications program such as ProComm or  HyperTerminal on the PC  Both programs can  be downloaded from various Internet sites   HyperTerminal is generally included with  distributions of the Windows Operating System     COM Port Settings  9600  8  N  1  9600 baud   8 data bits   No parity   1 stop bit   no flow control   no handshaking  full duplex       Teledyne Webb Research recommends the practice of capturing and archiving a log file of all  communications with each float  If in doubt about a test  email the log file to your chief scientist  and or to Teledyne Webb Research     Once you have started the communications program and completed the connections described  above  press  ENTER  to wake the float from Hibernate mode  The float will respond that it has  detected an  asynchronous wake up  and will enter Command mode  Press  ENTER  in  Command mode to display the main menu  Menu selections are not case sensitive  See  APF9A  Command Summary  for a complete list of available commands     33 of 40    Appendix E  APF9A Command Summary    Uppercase commands are used here for clarity  however  APF9A commands are not case  sensitive  The menus presented below were copied verbatim from a terminal session with an  APF9A controller    gt   is the APF9A prompt for operator input  The first menu is displayed in  response to either a question mark       or the  ENTER  when no preceding command is en
7.  A2 Binary input  hexadecimal output  e Result  output  format  DS All results from each satellite pass  e Compression  None Uncompressed   e Distribution strategy  Scheduled All results every 24 hours   e Number of bytes transmitted  31 per message            When using a 28 bit ARGOS ID  31 data bytes are transmitted in each message  32 data bytes are transmitted in  each message when using a 20 bit ARGOS ID     18 of 40    B  Test Messages   28 bit ARGOS ID   Mission Prelude    The test message block is comprised of two messages  Each of the 6 messages sent during the  Mission Activation phase is a Test Message 1  During the Mission Prelude the two test messages  alternate  with one sent during each ARGOS transmission  The formats of the two test messages  are show in the tables below     Test Message 1   28 bit ARGOS ID    Byte s   1  2  3    AUA    9 10  11 12  13  14  15  16    17    18  19   20  21  22  23  24  25  26  27  28   29  30  31  32    Mnemonic Description    CRC  MSG  BLK    MON  DAY  YR   FLT  SEC  STATUS  P   VAC  ABP    BAT    UP  DOWN  PRKP  PPP  NUDGE  OK  ASCEND  TBP   TP   TPP   N    Message CRC   Message ID   1 for Test Message 1   Message block ID   increments with each transmitted message  block and wraps at OxFF   F W Revision   Month   F W Revision   Day   F W Revision   Year  2 digit    Float ID  hull number    Time since the start of the Mission Prelude  seconds    Float status word   16 bits  see below   Pressure measured once for each test me
8.  Park phase   Standard deviation of pressure during Park phase   Minimum temperature during Park phase   Pressure associated with minimum temperature during Park phase  Maximum temperature during Park phase   Pressure associated with maximum temperature during Park phase  Minimum pressure during Park phase   Maximum pressure during Park phase   Not used   only exists for a float with a 20 bit ARGOS ID       24 of 40    The hydrographic data are transmitted in messages 3     N in the order that they were collected   The sample taken at the end of the Park phase is transmitted first followed by the samples  collected during the profile phase     Data Message 3   28 bit ARGOS ID  Byte s  Mnemonic Description    1 CRC  MSG    N     4 Tpark   6 Spark   7 8 Ppark  9 10 Tprofile  11 12 Sprofile  13 14 Pprofile    15 16 TI  17 18 Sl  19 20 Pl  Hear T  23 24 52  25 26 P2  2728  T3  29 30 S3   31 P3  half    32 NA    Message CRC   Message ID   each data message block is comprised of multiple  messages  this will be a 2 for Data Message 2  Temperature at end of Park phase   Salinity at end of Park phase   Pressure at end of Park phase   Temperature at start of Profile phase   Salinity at start of Profile phase   Pressure at start of Profile phase   Temperature  first point in depth table    Salinity   Pressure   Temperature  second point in depth table    Salinity   Pressure   Temperature  etc  to end of table    Salinity   Pressure  first byte  second byte in next message    Not used  
9.  is a CRC  Cyclic Redundancy Check  byte  The value is calculated by the float  not by  ARGOS  from the remaining bytes of that message  A bad CRC generally means a corrupted  message  Itis worth noting that a good CRC is a good indicator that the message is OK  but it is  possible to have a good CRC even when the message is corrupt  This is particularly true for a  short CRC   this one is only 8 bits long  Comparing multiple realizations of each ARGOS  message  e g   all received versions of Data Message 3 for some particular profile  to identify  uncorrupted versions of the message is strongly recommended     A sample code fragment in C that can be used to calculate CRC values is shown below  This  code was written by Dana Swift of the University of Washington  The original algorithm was  developed in the 1970s by Al Bradley and Don Dorson of the Woods Hole Oceanographic  Institution  The algorithm attempts to distribute the space of possible CRC values evenly across  the range of single byte values  0 to 255  Sample programs in C  Matlab  FORTRAN  and  BASIC can be provided by Teledyne Webb Research on request  The Matlab version provides  the user with a GUI interface into which individual ARGOS messages can be entered by cutting  and pasting with a mouse     static unsigned char CrcDorson const unsigned char  msg   unsigned int n       unsigned char i1 crc CrcScrambler msg 1       for  i 2  i lt n  i       crc    msgli    crc   CrcScrambler crc      return crc          s
10.  only exists for a float with a 20 bit ARGOS ID    The pattern of sequential PTS measurements continues in subsequent messages with  measurement triples breaking across message boundaries as necessary  The measurements each  occupy 2 bytes and are encoded as 4 hex characters  The procedures for converting these encoded  data from the hexadecimal format to physical units are described in the next section   Conversion  from Hexadecimal to Physical Units         25 of 40    Auxiliary Engineering Data   If there is space at the end of the last message in the block  it is filled with Auxiliary Engineering  data  These data are not used to generate an additional message and if they are not sufficient to  fill the available space the remaining bytes are set to OxFF  These data are comprised of the time  of profile initiation plus a series of pressure measurements taken at just after the piston is  retracted and at hourly intervals during the descent to the Park Depth  Descent rates are  calculated from these data  The information begins in the byte immediately following the end of  the hydrographic data  The table below shows an example        The byte immediately following the hydrographic data is the time of profile initiation  the time  difference in minutes between the start of the profile and the end of down time   The descent  pressure marks are next  The first byte is the count of the number of descent pressure mark  The  following bytes are the descent pressure measurements 
11.  phase  counts    Battery voltage while SBE41 sampling at end of Park phase  counts   Battery current while SBE41 sampling at end of Park phase  counts   Battery voltage measured just before the end of the initial piston  extension beginning Profile phase  counts    Battery current measured just before the end of the initial piston  extension beginning Profile phase  counts    Battery voltage while air pump running  counts    Battery current while air pump running  counts    Number of 6 second pulses of the air pump require to inflate the air  bladder    Integrated Measure of  Volt Sec  of volume of air pumped during  telemetry cycle    Not used   only exists for a float with a 20 bit ARGOS ID    22 of 40    The SBE41 status word is shown in the table below     SBE41 Status Word   16 bits    Bit  0x0001    0x0002    0x0004    0x0008  0x0010    0x0020  0x0040  0x0080  0x0100    0x0200  0x0400    0x0800  0x 1000    0x2000  0x4000  0x8000    Mnemonic  Sbe41PedanticExceptn    Sbe41PedanticFail  Sbe41RegexFail    Sbe41NullArg  Sbe41RegExceptn    Sbe41 NoResponse    Sbe41PedanticExceptn    Sbe41PedanticFail  Sbe41RegexFail    Sbe41NullArg  Sbe41RegExceptn    Sbe41NoResponse  Sbe41ConfigFail    Description    An exception was detected while parsing the P only  pedantic regular expression   The SBE41 response to P only measurement failed the  pedantic regular expression   The SBE41 response to P only measurement failed the  non pedantic regular expression   NULL argument detected dur
12.  shallow water and not be able to reach the some depths  The total number of messages will    include message   and message 2 plus the number of messages needed for the PTS data     The repetition period is known a priori or can be determined form the ARGOS time stamps on  sequential messages     Subtracting the Te calculated from a particular Message   from the message s time stamp  produces an estimate of the time at which the float surfaced  An example is shown below    Example Message 1    DS format  Block Number  2001 11 02 22 47 54 1 Byte 2  0x05 m  5  cF 01 05 02 Number of PTS measurements  AF 02 47 00 B    yte 6   0x47  gt  71  85 01 01 01  16 92 17 19 71 x 6   426 bytes  9E 94 01 AD Number of Msgs for data  85 09 1F 48   426 bytes   28 bytes per msg   16  97 9B 00 46 Total messages   Msg1   Msg2   Data Msgs  62 24 OE  1 1 16 n 18    Repetition Period p   46 seconds    31 of 40    Calculate the elapsed time on the surface   Te    m  1  x n x p    5   1  x 18 x 46   3312   00h 55m 12s    Subtracting this from the time stamp of the ARGOS message yields the approximate time of  arrival at the surface     22 47 54   00 55 12   20 52 42    The total time spent at the surface can now be calculated by subtracting Te from the known  expiration of the Up Time     Appendix B  Argos ID formats  28 bit and 20 bit    In 2002 Service Argos notified its users there were a limited number of 20 bit Ids available and  to begin preparing for a transition to 28 bit IDs  The 28 bit IDs re
13. 40    ll    APF9 Operations Warning for APF8 Operators    This APEX manual describes floats using a new controller design  The new design is designated  APF9  The prior design  which is still in production and widely used  is designated APF8     The operator interface and behavior of the APF9 are similar to  but not identical to  the operator  interface and behavior of the APF8  If you are an experienced APF8 user  please observe  appropriate cautions and do not assume an expected behavior  Several important differences  are listed below  These points should also be helpful to those without an APF8 background     e To reset an APF9 for a deployment you should hold the Reset Tool stationary against the  RESET label until you hear the air pump run  Typically  the air pump will run 2 to 3 seconds  after you position the Reset Tool over the RESET label   For the APF8 it was necessary to  hold the Reset Tool in place and then remove it to trigger the float     e The serial baud rate for communications is 9600  with 8 data bits  no parity  and 1 stop bit    The APF8 baud rate is 1200     e If not already in Command Mode  an APF9 can only enter Command Mode from Sleep   Either the Reset Tool or a keystroke at the terminal will trigger the transition from Sleep to  Command Mode    e If the APF9 is performing some task  e g   self tests   it is not listening and cannot be placed in  Command Mode with either the Reset Tool or a keystroke at the terminal    o There is one exception  If 
14. Physical Units    The temperature  salinity  pressure  voltage  and current values measured by the float are encoded  in the Data Messages as hex integers  This compression reduces the number of bytes in the  ARGOS transmissions  The resolution of the encoded hydrographic values is shown in the table  below     Measurement Resolution Range Data Format Conversion  Temperature 0 001   C  4 095   C to 16 bit unsigned T   Traw   1000  61 439   C with 2   s complement  Salinity 0 001 psu  4 095 psuto 16 bit unsigned S  Saw   1000  61 439 psu with 2   s complement  Pressure 0 1 dbar  3276 7 dbar 16 bit unsigned P  Paw  10  to 3276 7 dbar with 2   s complement  Volts V 8 bits unsigned V    Vaw   0 077   0 486  Current MA 8 bits unsigned I   law   4 052    3 606  Vacuum InHg 8 bits unsigned V    Vaw   0 293   29 767    To convert the hex values in an ARGOS message back to physical units  proceed as described in  the table below  The initial conversion from Hexadecimal to Decimal should assume the hex  value is an unsigned integer with a range of 0 to 65535 for temperature  salinity  and pressure  measurements  a range of 0 to 255 for voltage and current measurements and a range of 0 to 4095  for optode measurements  If temperature  salinity or pressure raw values are above the maximum  unisigned value listed  a 2   s complement conversion should be applied to obtain a signed   negative  value  This allows for representation of a full range of values     Decimal and Physical    Measur
15. ally 6 hours  o Air pump run during transmissions until air bladder is fully inflated       The float can be deployed after the Mission Activation phase and confirmation of proper float  function have been successfully completed  We advise waiting until the air bladder is fully  inflated during the first dozen or so test transmissions of the Mission Prelude before deploying  the float     7 of 40    B  Pressure Activation Deployment    To use the Pressure Activation feature you must first connect the provided communication cable  between your PC and the float  see  Connecting a Terminal  at the end of this manual for  additional information   The normal port settings for an APF9A are 9600  8  N 1  Press   ENTER  to wake the float from Hibernate mode  The float will respond that it has detected an   asynchronous wake up  and will enter Command mode  Press  ENTER  in Command mode to  display the main menu  Menu selections are not case sensitive        Press  a  or  A  to activate the Pressure Activation feature and start the deployment  The float will  run a brief self test  Mission Activation   During this time the operator should verify proper  function of the float  see below   Mission Activation and Operator Float Function Check   The  float will then fully retract the piston and deflate the air bladder so that it can sink when  deployed  Once the piston is fully retracted  the float enters the Pressure Activation phase   During this phase the float makes a pressure measure
16. duced from 32 to 31 the  number of data bytes in each message  Data provided by Argos will consist of 31 hex bytes per  message  Data acquired by use of an uplink receiver will consist of 32 hex bytes per message   The first byte  when using an uplink receiver  is a 28 bit ID identifier used by Argos and is not  represented in the Apex Data formats included in this manual     Appendix C  Storage conditions    For optimum battery life  floats should be stored in a controlled environment in which the  temperature is restricted to the range  10   C to  25   C  When activated  the floats should be  equilibrated at a temperature between  2   C and  54   C before proceeding with a deployment     If the optional VOS or aircraft deployment containers are used  they must be kept dry  and should  only be stored indoors     32 of 40    Appendix D  Connecting a Terminal    The float can be programmed and tested by an operator using a 20 mA current loop and a  terminal program  The current loop has no polarity  Connections should be made through the  hull ground and a connector or fitting that is electrically isolated from the hull  This is shown in  the image below  In this case one side of the current loop is clipped to the zinc anode and the  other is clipped to the pressure port     The communications cables and clamps are included in the float shipment  An RS 232 to  current loop converter is provided with the communications cables  This converter requires a 12  VDC supply     The RS
17. eal plug while loosening it  Use a 3 16 inch hex  wrench  provided   or pliers  to rotate the plug counter clockwise     Seal Plug       38 of 40    Appendix G  Missions    This section lists the parameters for each float covered by this manual     To display the parameter list  connect a communications cable to the float  press  lt ENTER gt  to  wake the float from hibernate and start command mode  and press  T  or  L  to list the parameters   See  Connecting a Terminal  and  APF9A Command Summary  for more information     IMPORTANT  Piston full extension  set with menu parameter Ff  is calibrated and set at  the factory  Do not alter the value of Ff shown in the    Missions    appendix  Using a value  larger than the factory setting may result in severe damage to the pump     Instrument   5098    APEX version 062608 sn 7147  3706D4C 28 bit hex Argos id  Ma   042 Argos repetition period  Seconds  Mr  INACTV ToD for down time expiration   Minutes  Mtc    225 Down time   Hours  Mtd  015 Up time   Hours  Mtu   009 Ascent time out   Hours  Mta  006 Deep profile descent time   Hours  Mtj  006 Park descent time   Hours  Mtk  006 Mission prelude   Hours  Mtp  1000 Park pressure   Decibars  Mk  2000 Deep profile pressure   Decibars  Mj  066 Park piston position   Counts  Mbp    000 Compensator hyper retraction   Counts  Mbh  016 Deep profile piston position   Counts  Mbj  010 Ascent buoyancy nudge   Counts  Mbn  022 Initial buoyancy nudge   Counts  Mbi    001 Park n profile cycle le
18. ecated      35 of 40    Deployment Parameter Menu     gt   AP  55    L  EX version 013108 sn 0000  1D479 28 bit hex Argos id  Ma  060 Argos repetition period  Seconds  Mr  INACTV ToD for down time expiration  Minutes  Mtc  240 Down time   Hours  Mtd  013 Up time   Hours  Mtu  009 Ascent time out   Hours  Mta  006 Deep profile descent time   Hours  Mtj  006 Park descent time   Hours  Mtk  006 Mission prelude   Hours  Mtp  1000 Park pressure   Decibars  Mk  2000 Deep profile pressure   Decibars  Mj  066 Park piston position   Counts  Mbp  000 Compensator hyper retractin  Counts  Mbh  016 Deep profile piston position   Counts  Mbj  010 Ascent buoyancy nudge   Counts  Mbn  022 Initial buoyancy nudge   Counts  Mbi     gt   ye    004 Park n profile cycle length   120 Maximum air bladder pressure   Counts  Fb    096 OK vacuum threshold   Counts  Fv  227 Piston full extension   Counts  Ff  016 Piston storage position   Counts  Fs  2 Logging verbosity   0 5  D  0002 DebugBits D  c745 Mission signature  hex         nu selections are not case sensitive    Print this help menu    Enter ARGOS ID in HEX    Buoyancy control agent    Compensator hyper retraction for park descent   0 254   counts   Ascent initiation buoyancy nudge   25 254   piston counts     j Deep profile piston position   1 254   counts     Ascent maintenance buoyancy nudge   5 254   piston counts   Park piston position  1 254   counts    Float vitals agent    Maximum air bladder pressure   1 254   counts    Piston full ex
19. ement Hexadecimal i  Conversion Steps Result       Temperature  gt 0 0x3EA6   lt 0xEFFF      gt  Taw   16038  T   Taw   1000     gt  16 038   C       Traw   62859     gt   Temperature  lt 0 OxF58B   gt  0xF001      Toscomplemen Taw   65536  2677          T  T2sComplement   1000     eS  Salinity Ox8FDD   lt OxEFFF      Saw   36829  S  Straw   1000     36 829 psu  Saw   61443  _ OxF003   gt  OxFO01      ee 7 7  Salinity S2sComplement Sraw 65536   4093   4 093 psu    S  S2sCompement   1000           27 of 40    Pressure  gt  0 0x 1D4C   lt  0x8000      Paw   7500                P   Paw   10     gt  750 0 dbar  Pressure  lt  0 OxFFFA   gt  0x8000      Pargaa   P2sCompliment   Praw   65536    6  0 6 dbar   P  P2sCompliment   10     Volts 0xBB     Viaw   187   V   Viaw  0 077    0 486  gt  14 9 V  Current 0x0A  gt  Law   LO   I   Law   4 052     3 606  gt  36 9 mA  Vacuum 0x56  gt  Viaw   86    V   Vraw  0 293   29 767  gt    4 5 inHg       Conversion Notes        The temperature range is  4 095   C to 61 439   C  Hex values OxF000  nonfinite   OxFO01     lt   4 095   OXEFFF     61 439   and OxFFFF  missing data  are used to flag out of range  measurements or are otherwise reserved  Temperatures in the range  0 0015   C to  0 0005   C are  mapped to OxXFFFE    The salinity range is  4 095 psu to 61 439 psu  Hex values OxFO00  nonfinite   OxFOO1     lt   4 095   OXEFFF     61 439   and OxFFFF  missing data  are used to flag out of range  measurements or are otherwise reserved  Salin
20. g shipping        6 of 40    A  Manual Deployment with the Reset Tool    Shortly before deployment  reset the profiler by holding the Reset Tool over the marked location  on the pressure case  Hold the Reset Tool in position for approximately 3 seconds  Remove the  Reset Tool only after you hear the air pump activate     The float will run a brief self test  This is the Mission Activation phase  During this time the  operator should verify proper function of the float  see  Mission Activation and Operator Float  Function Check    The float will then transmit test messages for 6 hours at the programmed  repetition rate during the Mission Prelude phase  Six hours is typical  the duration of the Mission  Prelude can be set by the operator  The piston will be fully extended at the beginning of the  Mission Prelude  before the test transmissions begin  and the air bladder will be fully inflated  during the first dozen or so test transmissions  At the conclusion of the Mission Prelude the float  will begin its pre programmed mission           Manual Deployment Summary     e Hold the Reset Tool over the RESET label  e Mission Activation  o Air pump runs once  o Self test conducted  see below for verification procedure     Internal tests run  can be monitored if communication cable is connected   see  Connecting a Terminal      6 ARGOS transmissions  o Piston EXTENDED fully  e Mission Prelude  o Test transmissions at the programmed repetition rate  o Mission Prelude duration is typic
21. h to confirm the pressure rating of specific floats   Do not exceed the rated pressure  or the hull may collapse     5 of 40    IV  Evaluating the Float and Starting the Mission    Profilers are shipped to the customer in Hibernate mode  The Pressure Activation feature is  NOT ACTIVE  With the Pressure Activation feature included in this version of the APF9A  firmware  there are two possible deployment procedures  The procedures are described below     IMPORTANT  Pressure Activation is NOT automatic for this firmware version of the  APF9A  The Pressure Activation feature MUST be MANUALLY ACTIVATED by the  OPERATOR using a PC to communicate with the float     The following sections   Manual Deployment with the Reset Tool  and  Pressure Activation  Deployment   provide operational summaries for these two possible deployment scenarios  Both  sections refer to self tests conducted by the float and float function checks performed by the  operator     A detailed description of proper float behavior  self tests  and the associated operator actions and  observations needed to evaluate the float for deployment is provided in  Mission Activation and    Operator Float Function Check      IMPORTANT  The float should not be deployed if it does not behave as described in   Mission Activation and Operator Float Function Check      Teledyne Webb Research  strongly recommends testing all APEX Profilers    on receipt by the customer and before deployment  to ensure no damage has occurred durin
22. he piston  and the first descent of the programmed mission will begin     Pressure Activated Deployment  Once the piston is fully retracted the float will enter the  Pressure Activation phase  During this phase it will check the pressure every two hours   hibernating in between  The float will not enter the Mission Prelude phase until it detects a  pressure in excess of 25 dbar  There will be no test transmissions nor inflation of the air  bladder until the Mission Prelude phase begins        When the trigger pressure is detected the float will extend the piston and begin the Mission  Prelude  making ARGOS test transmissions at the specified repetition rate and also running  the air pump to inflate the air bladder  see above   The duration of the Mission Prelude is  set by the operator  6 hours is typical  At the end of the Mission Prelude the ARGOS test  transmissions will cease  the float will deflate the air bladder and retract the piston  and the  first descent of the programmed mission will begin    10  The float is ready to deploy     12 of 40    E  Notes and Caveats  Self Tests  During the self tests the float checks     e The internal vacuum  e Communication with the CTD  e The internal alarm timer settings    If any of the self tests fail the float will abort the mission  The clearest indication to the operator  that this has occurred is the failure of the float to make the initial 6 ARGOS transmissions at  6 second intervals     If you do not detect these Mission Ac
23. in bars     Below is an example of a final message  The actual byte location of the last sample and start of  the auxiliary data will depend on actual number of samples collected  This is an example to  demonstrate auxiliary data format only     Final Data Message   28 bit ARGOS ID  Byte s    Mnemonic Description          1 CRC Message CRC  2 MSG Message ID   each data message block is comprised of multiple  messages  this will be a 2 for Data Message 2  3 4 TN 2 Temperature  5 6 SN 2 Salinity  7 8 PN 2 Pressure  9 10 TN 1 Temperature  second to last point in depth table   11 12 SN 1 Salinity  13 14 PN 1 Pressure  15 16 TN Temperature  last point in depth table   17 18 SN Salinity  19 20 PN Pressure  21 22 Ptime Profile initiation time  minutes  2   s compliment signed integer     positive values     profile initiated after down time expired    negative values     profile initiated before down time expired        23 NDM Number of descent pressure measurements   24 DMI Pressure taken at end of piston retraction   25 DM2 Pressure taken 1 hour after beginning of descent  bars    26 DM3 Pressure taken 2 hours after beginning of descent  bars   27 DM4 Pressure taken 3 hours after beginning of descent  bars   28 DM5 Pressure taken 4 hours after beginning of descent  bars   29 DM6 Pressure taken 5 hours after beginning of descent  bars   30 Filler OXFF   31 Filler OXFF   32 NA Not used   only exists for a float with a 20 bit ARGOS ID    26 of 40    D  Conversion from Hexadecimal to 
24. ing P only measurement  An exception was detected while parsing the P only  non pedantic regular expression   No response detected from SBE41 for P only request  Not  yet  used   Not  yet  used   An exception was detected while parsing the PTS  pedantic regular expression    The SBE41 response to PTS measurement failed the  pedantic regular expression   NULL argument detected during PTS measurement  An exception was detected while parsing the PTS non   pedantic regular expression   No response detected from SBE41 for PTS request  SBE41 error occurred during configuration   Not  yet  used    23 of 40    Data Message 2 continues with miscellaneous engineering data and statistics for the PTS  measurements taken periodically during the Park phase     Data Message 2   28 bit ARGOS ID    Byte s   1   2   3 6  7 8   9  10 11  12 13  14 15  16 17  18 19  20 21  22 23  24 25  26 27  28  29  30 31  32    Mnemonic Description    CRC  MSG    EPOCH  TINIT    NADJ  ParkN  TMean  PMean  StDevT       Message CRC   Message ID   each data message block is comprised of multiple  messages  this will be a 2 for Data Message 2   Unix epoch when down time expired  Apf9a RTC    Time  minutes  when telemetry phase was initiated relative to  EPOCH   2   s compliment signed integer    Number of active ballast adjustments made during Park phase   Number of samples collected during Park phase   Mean temperature during Park phase   Mean pressure during Park phase   Standard deviation of temperature during
25. ins to launch the  float  see  Deploying the Float    No further communications with the float is required and the  float can be reliably deployed by relatively inexperienced personnel        8 of 40    One caution is in order  The air bladder is not automatically inflated until the beginning of the  Mission Prelude phase of a deployment  This means it cannot be checked by the operator for  leaks during the normal course of a Pressure Activation deployment  Therefore  we strongly  recommend that you either        e Manually inflate and check the air bladder before starting a Pressure Activation  deployment  Be sure to manually close the air valve before trying to inflate the air bladder   Starting a Pressure Activation deployment will automatically deflate the bladder     Or     e Start a Manual Deployment with the Reset Tool or an operator command and reassert  operator control after the Mission Activation and initial portion of the Mission Prelude  phases  with attendant operator float function check  has successfully completed     Pressure Activation Deployment Summary     e Establish communication with the float  see  Connecting a Terminal    e Press  a  or  A   e Mission Activation  o Air pump runs once  o Self test conducted  see below for verification procedure     Internal tests run  can be monitored if communication cable is connected   see  Connecting a Terminal      6 ARGOS transmissions  o Air bladder deflated  o Piston RETRACTED fully  e Deploy the float  e Press
26. ities in the range  0 0015 psu to  0 0005 psu are  mapped to OxXFFFE    The pressure range is  3276 7 dbar to 3276 7 dbar  Hex values 0x8000  nonfinite   0x8001     lt   3276 7   OX7FFF    32767 7   and OxFFFF  missing data  are used to flag out of range  measurements or are otherwise reserved  Pressures in the range  0 15 dbar to  0 05 dbar are  mapped to OxXFFFE     28 of 40    E  Depth Table 65 for PTS Samples    Depth Tables 65 below  with values expressed in decibars  dbar   defines where PTS  measurements are acquired during a profile     Depth Table No  65    Sample Pressure Sample Pressure Sample Pressure  Point  dbar  Point   dbar  Point  dbar     Bottom  1 2000 27 550 53 170  2 1900 28 525 54 160  3 1800 29 500 55 150  4 1700 30 475 56 140  5 1600 31 450 57 130  6 1500 32 425 58 120  7 1450 33 400 59 110  8 1400 34 375 60 100  9 1350 35 350 61 90  10 1300 36 340 62 80  11 1250 37 330 63 70  12 1200 38 320 64 60  13 1150 39 310 65 50  14 1100 40 300 66 40  15 1050 41 290 67 30  16 1000 42 280 68 20  17 950 43 270 69 10  18 900 44 260 70 4or surf  19 850 45 250  20 800 46 240  21 750 47 230  22 700 48 220  23 650 49 210  24 625 50 200  25 600 51 190  26 575 52 180    To prevent fouling of the CTD by surface and near surface contaminants  the shallowest PTS  sample is taken when the pressure is between 6 dbar and 4 dbar     29 of 40    F  Telemetry Error Checking  CRC     ARGOS messages can contain transmission errors  For this reason the first element of each  message
27. me limit for descending from the surface and drifting  at the Park Depth  Down Time is commonly set to 10 days or to  10 days less the Up Time    e Up Time Programmed time limit for ascending from the Park or the Profile    Depth and drifting at the surface while transmitting the data acquired  during the profile  Up Time is typically set between 12 hours and  20 hours  increasing with the amount of data to be transmitted per  profile  The latitude of the deployment also matters  ARGOS  satellites are in polar orbits  so the number of satellite passes per day  increases with latitude    e Ascent Rate The ascent rate of the float is maintained at or above 8 cm s  The  float extends the piston by a user specified amount to add buoyancy  when the ascent rate falls below this threshold     A  Profile Ascent Timing    Profiles from the Park Depth begin when the operator programmed Down Time expires  The  float extends the piston by an operator programmed initial amount and begins the ascent  A PTS  sample is collected at the end of the Park phase     When a profile is to begin from the Profile Depth  the float will retract the piston and descend  from the Park Depth an operator programmed interval before the expiration of the Down Time   This interval  Parameter Mtj  Deep profile descent time in hours  provides the additional time  needed to descend to and profile from the Profile Depth without losing significant surface time   the period when data from the profile are transmitted
28. ment every two hours  hibernating between  measurements  If the pressure is less than 25 dbar the float returns to hibernation  If the pressure  exceeds 25 dbar the float fully extends the piston and begins the Mission Prelude with test  transmissions and air bladder inflation     During the Pressure Activation phase the operator can communicate with the float  This does  NOT NORMALLY deactivate Pressure Activation  However  a k  or  K   kill  command during  this phase will deactivate Pressure Activation and stop the mission     DO NOT DEPLOY THE FLOAT AFTER A KILL  K  COMMAND UNLESS YOU HAVE  STARTED A MANUAL DEPLOYMENT OR RESTARTED A PRESSURE  ACTIVATION DEPLOYMENT  IF YOU FAIL TO OBSERVE THIS CAUTION AND  LAUNCH THE FLOAT IT WILL SINK TO A NEUTRAL DEPTH AND STAY THERE   IT WILL NOT SURFACE AGAIN     In the absence of a kill command the float will automatically resume the Pressure Activation  phase after several minutes without operator input  Placing the Reset Tool over the RESET mark  during the Pressure Activation phase will start a deployment     Pressure Activation Deployment Scenario    Using the Pressure Activation feature minimizes operator float interaction while at sea  A skilled  operator can fully test the float while still in the laboratory environment or while the vessel is still  at the dock  At the conclusion of testing the Pressure Activation feature can be activated and the  float can be left to await deployment  When the vessel is on station it only rema
29. ngth  Mn  120 Maximum air bladder pressure   Counts  Mfb  096 OK vacuum threshold   Counts  Mfv    226 Piston full extension   Counts  Mff   022 Piston storage position   Counts  Mfs  2 Logging verbosity   0 5  D   0002 DebugBits  D   02ac Mission signature  hex      39 of 40    Instrument   5099    APEX version 062608 sn 7148  3706D8B 28 bit hex Argos id  Ma   044 Argos repetition period  Seconds  Mr  INACTV ToD for down time expiration   Minutes  Mtc    225 Down time   Hours  Mtd  015 Up time   Hours  Mtu   009 Ascent time out   Hours  Mta  006 Deep profile descent time   Hours  Mtj  006 Park descent time   Hours  Mtk  006 Mission prelude   Hours  Mtp  1000 Park pressure   Decibars  Mk  2000 Deep profile pressure   Decibars  Mj  066 Park piston position   Counts  Mbp    000 Compensator hyper retraction   Counts  Mbh  016 Deep profile piston position   Counts  Mbj  010 Ascent buoyancy nudge   Counts  Mbn  022 Initial buoyancy nudge   Counts  Mbi    001 Park n profile cycle length  Mn  120 Maximum air bladder pressure   Counts  Mfb  096 OK vacuum threshold   Counts  Mfv    226 Piston full extension   Counts  Mff   022 Piston storage position   Counts  Mfs  2 Logging verbosity   0 5  D   0002 DebugBits  D   75b8 Mission signature  hex      40 of 40    
30. ote  It can be difficult to replace the plug  when the air bladder is fully inflated  We  suggest that you reinsert the plug before  the bladder is fully inflated  The plug  prevents the entry of silt into the cowling  in the event the float contacts the sea floor           10 of 40    5     6     7     8     Start a Manual or Pressure Activated Deployment as described above in the  Manual  Deployment with the Reset Tool  and  Pressure Activation Deployment  sections  This  will trigger the Mission Activation self tests  Where applicable  the description below  indicates where the two versions of the self tests differ           Verify by ear that the air pump is activated for approximately 1 second     DO NOT DEPLOY THE FLOAT IF IT DOES NOT BEHAVE AS DESCRIBED  BELOW  FLOATS THAT DO NOT PASS THE SELF TESTS SHOULD NOT BE  DEPLOYED  CONTACT Teledyne Webb Research FOR ASSISTANCE     The float will conduct self tests for approximately 15 seconds  Progress and diagnostic  messages will be displayed if a terminal is connected to the float  see  Connecting a  Terminal  for additional information      If the float passes the self tests   it will make 6 ARGOS  transmissions with a 6 second  interval  You can detect these  transmissions using the  cat s  meow  sensor as shown in the  image at right  Hold the sensor  parallel to and within 15 cm    6 inches  of the float s antenna   The cat s meow will beep during  each ARGOS transmission  Do  not deploy the float if you do not  detect 
31. ssage block  centibars   Vacuum measured during self tests  counts    Air bladder pressure measured once for each test message block   counts    Quiescent battery voltage measured once for each test message  block  counts    Up time  hours    Down time  hours    Park pressure  decibars    Park piston position  counts    Buoyancy nudge during ascent  counts    Internal vacuum threshold  counts    Ascent time out  hours    Maximum air bladder pressure  counts    Profile pressure  decibars    Profile piston position  counts    Park and profile cycle length   Not used   only exists for a float with a 20 bit ARGOS ID    19 of 40    Test Message 2   28 bit ARGOS ID    Byte s   1  2  3    ONNNA    O    11  12  13  14  15 16    17 18    19   22  23   24    25   26  27     32    Mnemonic Description    CRC  MSG  BLK    MON  DAY  YR  FEXT  FRET  IBN  CHR  DPDP  PDP  PRE  REP  SBESN    SBEFW    EPOCH  TOD    DEBUG    Message CRC   Message ID   2 for Test Message 2   Message block ID   increments with each transmitted message  block and wraps at OxFF   F W Revision   Month   F W Revision   Day   F W Revision   Year  2 digit    Piston full extension  counts    Piston full retraction  counts    Initial buoyancy nudge  starts profile   counts    Compensator hyper retraction  counts    Deep profile descent period  hours    Park descent period  hours    Mission prelude period  hours    ARGOS transmission repetition period  seconds    Seabird SBE41 serial number  encoded as a hex integer  e g 
32. ssion Prelude  Data Messages   28 bit ARGOS ID   Conversion from Hexadecimal to Physical Units  Depth Table 65 for PTS Samples   Telemetry Error Checking  CRC     18  19  22  27  29  30  31       32       32       33       34       Appendix F  Returning APEX floats for factory repair or refurbishment    Appendix G  Missions    38       39       2 of 40    l  Alkaline Battery Warning    The profiler contains batteries comprised of alkaline manganese dioxide  D  cells     There is a small but finite possibility that batteries of alkaline cells will release a combustible gas  mixture  This gas release generally is not evident when batteries are exposed to the atmosphere    as the gases are dispersed and diluted to a safe level  When the batteries are confined in a sealed  instrument mechanism  the gases can accumulate and an explosion is possible     Teledyne Webb Research has added a catalyst inside of these instruments to recombine hydrogen  and oxygen into H20  and the instrument has been designed to relieve excessive internal pressure  buildup by having the upper end cap release     Teledyne Webb Research knows of no way to completely eliminate this hazard  The user is  warned  and must accept and deal with this risk in order to use this instrument safely as so  provided  Personnel with knowledge and training to deal with this risk should seal or operate the    instrument     Teledyne Webb Research disclaims liability for any consequences of combustion or explosion     3 of 
33. tatic unsigned char CrcScrambler unsigned char byte      unsigned char sum 0 tst    if C byte  byte   Oxff    tst   byte  if  tst   2  sum      tst  gt  gt   2  if  tst   2  sum      tst  gt  gt   1  if  tst   2  sum      tst  gt  gt   1  if  tst   2  sum      sum    2     return  byte gt  gt 1    Csum lt  lt 7      30 of 40    Appendix A  Surface Arrival Time and Total Surface Time    Calculating surface drift vectors may require that you estimate the surface arrival time  Although  each message is time stamped by ARGOS  there may not be a satellite in view at the time the  float surfaces  In this case the initial messages are not received     ARGOS telemetry begins when the float detects the surface  The messages are transmitted in  numerical order starting with Message 1  When all of the messages in the block have been  transmitted the cycle repeats  Transmissions continue at the programmed repetition rate until the  Up Time expires     The elapsed time since surfacing can be estimated using the message block number  m   the  number of messages in the block  n   and the programmed ARGOS repetition period  p      Te   m  1 xnxp  The block number  BLK  is included in each ARGOS message set   The total number of messages can be determined from the information in Data Message 1  which  includes the number of PTS measurements made during the profile  LEN   Note that this value  may not be the same as the number of entries in the depth table  For example  a float may drift  into
34. tension   1 254   counts    Display float serial number    Storage Piston Position   1 254   counts    OK vacuum threshold   1 254   counts    List mission parameters    Park and profile cycle length   1 254    Deep profile Pressure   0 2000   decibars    Park Pressure   0 2000   decibars    Quit the mission programming agent    Repetition period for Argos transmissions  30 120   sec    Mission Timing Agent   Ascent time out period   1 10 hours   Hours     36 of 40    Td Down time  0 336 hours   Hours     Tj Deep profile descent time   0 6 hours   Hours    Tk Park descent time   0 6 hours   Hours     Tp Mission prelude   0 6 hours   Hours     Tu Up time  0 24 hours   Hours     Z Analyze the current mission programming    Buoyancy Parameter Menu   gt  B    Menu of buoyancy control parameters   Print this menu   ah Compensator hyper retraction for park descent   0 254   counts   Bi Ascent initiation buoyancy nudge   25 254   piston counts   Bj Deep profile piston position   1 254   counts   Bn Ascent maintenance buoyancy nudge   5 254   piston counts   Bp Park piston position  1 254   counts     Timing Parameter Menu   gt T   Menu of mission timing parameters   Print this menu   a Ascent time out period   1 10 hours   Hours   Td Down time  0 336 hours   Hours    Tj Deep profile descent time   0 6 hours   Hours    Tk Park descent time   0 6 hours   Hours    Tp Mission prelude   0 6 hours   Hours    Tu Up time  0 24 hours   Hours      SBE41 Menu   gt  S    Menu of SBE41 functions
35. ter  let go of the  lower end of the rope and pull on the top end slowly and carefully until the rope clears the  hole and the float is released     It may take several minutes for the cowling to fully flood with water and the float may drift  at an angle or even rest on its side during this period  This is normal behavior and not a  cause for concern     Manual Deployment  The float will remain on surface for the duration of the Mission  Prelude     Pressure Activated Deployment  The float will sink immediately  It will return to the  surface within 3 hours and begin the Mission Prelude after detecting a pressure in excess of  25 dbar     14 of 40    VI  Park and Profile    The APF9A float can be set to profile from a maximum depth  Profile Depth  after a  programmable number  N  of profiles from a shallower depth  Park Depth   Special cases are  conducting all profiles from either the Profile Depth or the Park Depth  The latter is an important  special case that can be selected by setting N   254  This will cause all profiles start at the Park  Depth  the programmed Profile Depth is ignored  Between profiles the float drifts at the Park  Depth     Terminology    e Park Depth Intermediate depth at which the float drifts between profiles and from  which the float profiles in cycles not evenly divisible by N    e Profile Depth Maximum depth to which the float descends from the Park Depth  every Nth cycle and from which each Nth profile is conducted    e Down Time Programmed ti
36. tered     IMPORTANT  Piston full extension  set with menu parameter Ff  is calibrated and set at  the factory  Do not alter the value of Ff shown in the    Missions    appendix  Using a value  larger than the factory setting may result in severe damage to the pump     Main Menu     gt     Menu selections are not case sensitive   Print this help menu   Initiate pressure activation of mission   Calibrate  battery volts  current   amp  vacuum   Set logging verbosity   0 5   Execute  activate  mission   Diagnostics agent     Diagnostics menu   Kill  deactivate  mission   List mission parameters   Mission programming agent     Mission programming menu   Display the pressure table   Exit command mode   Seabird CTD agent     Seabird CTD menu   Get Set RTC time   format  mm dd yyyy hh mm ss      ANNOPVESCMPAXRHMONS N    Diagnostics Menu     gt  I    Menu of diagnostics    Print this menu    Run air pump for 6 seconds    Move piston to the piston storage position   Close air valve    Display piston position   Extend the piston 4 counts    Goto a specified position   1 254   counts   Open air valve    Retract the piston 4 counts    Argos PTT test    Calculate ToD down time expiration    Run air pump for 6 seconds  deprecated      PNarADTOuMUAaAaAnTNA   N    34 of 40    WO CON MUN    Argos PTT test  deprecated    Retract the piston 4 counts  deprecated    Extend the piston 4 counts  deprecated    Display piston position  deprecated    Open air valve  deprecated     Close air valve  depr
37. the piston is moving  the Reset Tool  but not a  keystroke  can be used to terminate the move  The APF9 will transition to its next  state or task  Typically this will be either Command Mode or Sleep  so try a  keystroke or a second application of the Reset Tool after the piston stops to  confirm or trigger the transition to Command Mode    e If the APF9 is not responding  it is probably busy with some task  Be patient and occasionally  try to get the attention of the float with either the Reset Tool or a keystroke     4 of 40    lll  Maximum Operating Pressure    APEX profilers have a maximum operating pressure of 2000 dbar  2900 psi   However  for  shallower applications  thinner walled pressure cylinders can be used  These cylinders have a  reduced pressure rating  but less mass  which allows them to carry a larger battery payload   Three cylinder pressure ratings are available     e 2000 dbar maximum pressure rating  e 1500 dbar battery payload typically 14  greater than with 2000 dbar cylinder  e 1200 dbar battery payload typically 28  greater than with 2000 dbar cylinder    For example  if an APEX profiler is specified by the customer for 1400 dbar maximum  profile   depth  then the 1500 dbar cylinder would normally be used     CAUTION   If you will be     e Exposing floats to significant hydrostatic pressure during ballasting or testing  e Re ballasting and re programming floats for a depth greater than the original specification    Please contact Teledyne Webb Researc
38. the six  6  ARGOS  transmissions           Manual Deployment  If not  already fully extended  the float Float Antenna Tranemiesian deleto  will fully extend the piston    This process may require up to   25 minutes  The oil bladder will expand during this time     Pressure Activated Deployment  If not already fully retracted  the float will fully retract the  piston  This process may require up to 25 minutes  The oil bladder will deflate during this  time        The volume of oil in the bladder is difficult to detect by hand  You may be able to hear the  pump by placing your ear against the hull     11 of 40    9     Manual Deployment  Once the piston is fully extended the float enters the Mission Prelude  phase  During this phase it will transmit test messages at the operator specified ARGOS  repetition period  These transmissions can be detected with the Cat s Meow  The float will  run the air pump for 6 seconds during each test transmission until the air bladder is fully  inflated  Inflating the air bladder typically requires 8 to 10 repetitions  Check for air  bladder inflation by sticking your finger  not a tool   through the hole in the bottom of the  yellow cowling as described in Step  4  above  Don t forget to replace the plug before  deploying the float        The duration of the Mission Prelude is set by the operator  6 hours is typical  At the end of  the Mission Prelude the ARGOS test transmissions will cease  the float will deflate the air  bladder and retract t
39. tivation transmissions with the Cat s Meow   DO NOT DEPLOY THE FLOAT     Manual Deployment  In the case of a Manual deployment  if the float is not deployed before the  completion of the Mission Prelude phase        RESET the float again and wait for it to complete the Mission Activation phase and begin  the Mission Prelude before you deploy it     Pressure Activated Deployment  In the case of a Pressure Activated Deployment  the operator is  necessarily absent when the float begins the Mission Prelude  This means the operator does not  have the opportunity to check the air bladder for leaks that a Manual Deployment offers        For this reason we strongly recommend that you manually inflate and check the bladder  before starting a Pressure Activated Deployment     13 of 40    1     2     3     4     5     Deploying the Float    Pass a rope through the hole in the plastic  damper plate  which is shown in the image at  right  The rope should fit easily through the hole  and be capable of supporting 50 kg  100 Ib      Holding both ends of the rope bight  carefully  lower the float into water  The damper plate is  amply strong enough to support the weight of  the float  However  do not let rope slide rapidly  through the hole as this may cut the plastic disk and release the float prematurely        Take care not to damage the CTD or the ARGOS antenna against the side of the ship while  lowering the float     Do not leave the rope with the instrument  Once the float is in the wa
40. ure Activation  o Pressure measured every 2 hours  o Pressure in excess of 25 dbar extends piston  inflates air bladder  triggers  transition to Mission Prelude  e Mission Prelude  o Test transmissions  6 hours typical   o Air pump run during transmissions until air bladder is fully inflated          The float can be deployed after the Mission Activation phase and proper functioning of the float  have been successfully completed     C  Mission Activation and Mission Prelude ARGOS Transmissions  The six ARGOS transmissions during Mission Activation and the transmissions during the    Mission Prelude contain data about the instrument  The information needed to decode these  messages is provided in the  ARGOS Data  section of this manual     9 of 40    1     2     3     4     Mission Activation and Operator Float Function Check  Secure the float in a horizontal position using the foam cradles from the shipping crate     The minimum internal temperature of the float is  2 0  C  If necessary  allow the float to  warm up indoors before proceeding     Remove the plastic bag and three  3  plugs from the CTD sensor as shown in the two  images below        Carefully remove the black rubber plug from the bottom center of the yellow cowling as  shown in the image below  This will allow you to verify air bladder inflation in the steps  below  Use only your fingers to remove  the plug  Tools may puncture or  otherwise harm the bladder  Be sure to    replace the plug before deployment     N
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
SoundStage! January 2005  知的財産を活かす経営戦略の策定へ  La simulation globale à l`épreuve de la formation à distance  ラック“全部”割 キャンペーン  RA890G Protectorelay  Digital Wireless Colour Camera Recordable CCTV Kit  Haier LE39F32800 User's Manual  H8S/2168F E10A Emulator User`s Manual  L-862/E - ERET-PT  - ADB Airfield Solutions  Honda Power Equipment 00X31-VL0    Copyright © All rights reserved. 