1. DOS level see Table 1 page 10 Table1 Calling the software Entry Recommended monitor micro lt Return gt micro COL lt Return gt Colour monitor micro BW lt Return gt Liquid crystal display and Plasma monitor micro GR lt Return gt Monochrome monitor micro NOSPS lt Return gt projecting without PLC applies to mouse operation at COM1 interface micro MODEM lt Return gt enable use of modem PLC 10 Installation 33 AKF User Club The AKF User Club was created to offer you optimal possibilities for saving time and expenses in your planning efforts Services As a member of the User Club you will automatically receive information about Improved features Software housekeeping Extra documentation Applications Training seminars workshops Up to the minute application examples general purpose and special technologi cally oriented ones By joining the AKF User Club you will have the opportunity to share in experi ence and software with other users You will be sent a ready file in DIN A4 format with registers for sorting the infor mation that you receive Membership The members of the AKF User Club are primarily employees who are registe red with us by name of customers or Groupe Schneider branches Apply for membership with the Software License Agreement gt Note Please do not forget to send in the Software License Agree ment giving your full name and address or that of your company 33 A
2. Esc key actuate the keys Ctrl Alt and Del simultaneously begin with Ctrl and end with Del 33 Objectives The installation instructions are for the installation of the software MICROAKF on the PADT Arrangement of This Guide Chapter 1 General Chapter 2 This chapter gives you information about the selection of the programming panel additional memory upgrades and the installation of the software and the drivers on the pro gramming panel Validity Note This instruction manual is valid for the software MICROAKF version 2 0 2 1 33 33 Handling 3 1 2 Diskettes i i Store diskettes in protective 4 No cleaning of diskettes Sont iners and baras Temperature 10 to 60 C Humidity 8 to 80 Insert diskettes correctly No heavy objects on diskettes OC f Diskettes tolerate no heat Label diskettes at the sunshine right spot Pa No forcing diskettes into disk drive No diskettes near mag netic fields O O 6 Always keep in mind gt 33 xi Xii 33 Table of Contents 33 Chapter 1 Chapter 2 Introduction 0c cece eee nun nn 1 OVENVIOW Eee Cha eee Shots BOR Atle ded 2 Installation a 3 Device selection Requirements 4 Important Remarks een een 4 Requirements P810 P820C P840C 5 Requirements IBM compatible PC 6 Requirements OS 2 eee eee 6 Creating a Backup oooc
3. Insert the MFO 1 diskette into the drive Enter A INSTAL and press lt Return gt A is here used to designate your diskette drive Enter the drive into which the program diskette has been inserted preset value A and confirm by pressing lt Re turn gt 33 Reakt The installation program will show the screen Install Deinstall End Help F18 LEI EISEN o Miera o Step 6 Open the installation menu by pressing lt Return gt Response The MICROAKF window will open Install Deinst AKF for MICRO Step7 Start the software installation by pressing Returns Step8 Follow the directions displayed on the screen Step9 Using move the selection bar lt gt gt to End and press lt Re turns Now you can call up the programming software see chapter 2 4 33 Installation 9 2 3 2 Deinstallation After pressing lt Return gt the following window appears 11 Deinstall En AKF for MICRO The deinstallation functions erase the software files on your programming panel Your systems and stations are not affected 2 3 3 End This menu item is used to leave the installation program after completing instal lation Installation may be broken off at certain specified places by pressing lt Esc gt In that case the user diskette drive prompt will immediately be returned e g C1 2 4 Calling the software Modsoft AKF gt Micro Start the software on the MS
4. KF User Club 11 Club Services and Processing of Applications Address for AKF User Club Groupe Schneider Buiseness Unit Automation International Subdivision Automation Technology MODICON AKF USER CLUB H Herforth Steinheimer Str 117 D 63500 Seligenstadt Address for Application Exchange Groupe Schneider Buiseness Unit Automation International Subdivision Automation Technology MODICON V12 H K mmerer Steinheimer Str 117 D 63500 Seligenstadt 12 AKF User Club 33 Index A AKF User Club 11 Club Services 12 Membership 11 B Back up copy 7 C Calling the software 10 D Deinstallation 10 Device selection SW Installation 4 Modsoft AKF User Club Services 11 33 Installation Software 8 S Software Call 10 Installation 8 W Warm restart 8 Index 13 14 Index
5. Modsoft AKF Micro Type MICROAKF Version 2 0 2 1 Installation User Instruction DOK 704104 33 1197 Translation of the German Description DOK 703409 Belongs to software kit E No 424 704 703 Documents in the software package Documentation Installation User Instruction DOK 704104 MICROAKF for Beginners User Instruction DOK 704105 Short Form Guide User Instruction DOK 704106 SFB Block Library DOK 704572 Configuration User Instruction DOK 704107 Masterindex User Instruction DOK 704108 Area of application Explains the usage and installation of the dis kettes included Serves to introduce new customers to MICROAKF The user learns how to use the software in small steps Tables for validity ranges and system mar kers SFB Formal operands for quick use on site Description of the Standard Function Blocks Contains the new features of the current ver sion and explains the functions of the indivi dual software menus for the configurer Index of all documentation Documents in the software package iii iv Documents in the software package Notes Application Note A Caution The relevant regulations must be observed for control applications involving safety requirements For reasons of safety and to ensure compliance with docu mented system data repairs to components should be per formed only by the manufacturer Training Schneider Automation offers suitable training that pro
6. cccccccccccc nrnna 7 Software installation 000 cece eee eee 8 MICROAKF software installation 8 Deinstallation cece eee eee 10 End av ae heaped anes te ad 10 Calling the software Modsoft AKF Micro 10 AKF User Club 0 0 cece eeeeeees 11 Index iii en 13 Table of Contents xiii Xiv Table of Contents Chapter 1 Introduction Introduction 1 1 1 Overview This publication tells you how to install the Modicon software kits The software is suitable for IBM compatible personal computers using the MS DOS operating system in particular the IBM compatible programming panel distributed by Schneider Automation Software installation of Modicon software is menu driven In this way existing user programs are safeguarded It is recommended that the programming panel be prepared for Modicon software even if the operating system has already been installed Note Henceforth the programming panels shall be referred to as PADT programming and debugging tool Programmable controllers shall be referred to as PLC With your PADT and the software provided you can program the Micro program mable controllers With the aid of the programming panel the programs can be created documented and archived The MS DOS operating system makes it possible to use the programming panel as a personal comuter as well 2 Introduction 33 Chapter 2 Installation This chapter describes t
7. d information is given which is intended exclusively for experts special training re quired Skipping this information does not interfere with understand ing the publication and does not restrict standard application of the product Path This symbol identifies the use of paths in software menus Figures are given in the spelling corresponding to international practice and ap proved by SI Systeme International d Unit s l e aspace between the thousands and the usage of a decimal point e g 12 345 67 33 vii Abbreviations ABS Adr AKF IL AWP DB 0 9 D Word 1 0 FB FBD G Word HW IB LD OB PB PADT React SFB PLC SSP SW SYM SYM COM SA lt Return gt lt Esc gt lt Ctrl gt lt Alt gt lt Del gt viii absolute addressing Address signal address Instruction List Ladder Diagram Function Block Diagram Instruction List User program Data block SYM COM block Double word Input Output siganls e g of a module Function block Function Block Diagram Floating point word Hardware e g PLC Initialization block Ladder diagram Organisation block Program block Programming and debugging tool Programming panel Reaction during descriptions of steps on screen Standard function block Programmable controller system programmable controller Signal memory Software Symbolic addressing Symbols and comments Node actuate the Return key actuate the
8. he selection of programming panels the installation of the software on the programming panel and how to call up the software Note Specific performance data for the software packages are gi ven in the Modicon automation catalogues 33 Installation 3 2 1 2 1 1 4 Device selection Requirements Important Remarks Note The P810 P820C and P840C guarantee optimal operation Caution For MS DOS version 3 3 or higher The MS DOS com mand APPEND may not be used with this software the APPEND command may not lead to AKF directories Caution MS DOS versions other than 3 x or 5 0 only P310 re liable implementation of the AEG software is not possible due to inadequate compatibility Caution When using the MS DOS Version 6 0 the Micro AKF function Special Archiving a Station and Special Restor ing a Station cannot be carried out Caution Do not start any memory resident or interrupt control led IBM PC programs parallel to the AEG software available me mory is insufficient Caution The OS 2 parameter direct access to HW Timer must not be set to yes as a time out will occur after only 3 to 4 se conds Installation 33 2 1 2 Requirements P810 P820C P840C In order to program an Micro with the present software you will need a a programming panel PADT P810 P820C P840C with O O CONFIG SYS File Entry for Buffers 20 Files 20 available user memory MS DOS befo
9. re calling MICROAKF at least 570 kByte minimum hard disk memory 2 MB required no memory resident programs started on PADT MS DOS versions 3 x 5 0 or 6 0 a PADT interfaces O 33 COM1 for operating the programmable controller on the PADT for program compilation initial start up COM2 optional for connecting a mouse or printer for design documentati on monitoring LPT1 optional for connecting a printer for design documentation monito ring Installation 5 2 1 3 Requirements IBM compatible PC In order to program an Micro with the present software on an IBM compatible PC you will need a an IBM compatible programming panel PADT with o Diskette drive 3 1 2 a CONFIG SYS file Entry for Buffers 20 Files 20 a 1 MByte RAM of which the available user memory MS DOS before cal ling MICROAKF is to be at least 570 kByte minimum hard disk memory 2 MB required US keyboard driver no resident programs started on the PADT MS DOS version 3 x 5 0 or 6 0 oO O DO O o PADT interfaces a COM1 for programmable controller operation on the PADT for programme compilation initial start up a COM2 optional for connecting a mouse or printer for design documentati on monitoring o LPT1 optional for connecting a printer for design documentation monito ring 2 1 4 Requirements OS 2 For installation of the software Modsoft AKF choose the OS 2 standard installa tion Note To load the Flash memo
10. ry it is recommended to leave the DOS Box 6 Installation 33 2 2 Creating a Backup A backup can be made of every original diskette included in the software kit The required number of blank diskettes corresponding to the number of original dis kettes should be kept available Proceed on the operating system level as follows Step 1 Type Diskcopy a a Step2 Follow the instructions on the screen Step3 Answer the question Make further copies Y N with Y until all the original diskettes have been copied IF Note Label the backup copies to match the original diskette s To prevent data loss store the originals in a safe place 33 Installation 7 2 3 Software installation Software installation is carried out using the prepared backup copies Note Nothing needs to be erased to overwrite an old software ver sion with a more recent one The old files are automatically overwritten with the command A INSTAL Note Please make backup copies of the original diskettes see chap ter 2 2 and use these copies here 2 3 1 MICROAKF software installation Step 1 Step 2 Response Step 3 Step 4 Step 5 8 Installation Ensure that your programming panel meets the require ments of Chapter 2 1 If the CONFIG SYS or AUTOEXEC BAT files have been modified the PADT can be reset by means of lt Ctrl gt lt Alt gt lt Del gt restart The prompt for the drive in use will appear e g CA
11. vides further information concerning the system see addresses Data Illustrations Alterations Data and illustration are not binding We reserve the right to alter our products in line with our policy of continuous product development If you have any sugges tions for improvements or amendments or have found errors in this publication please notify us by using the form on the last page of this publication Addresses The addresses of our Regional Sales Offices Training Centers Service and En gineering Sales Offices in Europe are given at the end of this publication 33 Vv Copyright All rights reserved No part of this document may be reproduced or transmitted in any form or by any means electronic or mechanical including copying pro cessing or any information storage without permission in writing by the Schneid er Automation You are not authorized to translate this document into any other language Trademarks All terms used in this user manual to denote Schneider Automation products are trademarks of the Schneider Automation 1997 Schneider Automation GmbH All rights reserved vi 33 Terminology y gt Note This symbol emphasizes very important facts Caution This symbol refers to frequently appearing error sources Warning This symbol points to sources of danger that may cause financial and health damages or may have other aggravat ing consequences Expert This symbol is used when a more detaile