Home
animeo® IB+ Operating software
Contents
1. Error nr Definition 128 Sun sensor 1 exterior sensor box 1 Not connected 129 Sun sensor 2 exterior sensor box 1 Not connected 130 Sun sensor 3 exterior sensor box 1 Not connected 131 Sun sensor 4 exterior sensor box 1 Not connected 132 Sun sensor 5 exterior sensor box 1 Not connected 133 Sun sensor 6 exterior sensor box 1 Not connected 134 Sun sensor 7 exterior sensor box 1 Not connected 135 Sun sensor 8 exterior sensor box 1 Not connected 136 Sun sensor 1 exterior sensor box 1 Short circuit 137 Sun sensor 2 exterior sensor box 1 Short circuit 138 Sun sensor 3 exterior sensor box 1 Short circuit 139 Sun sensor 4 exterior sensor box 1 Short circuit 140 Sun sensor 5 exterior sensor box 1 Short circuit 141 Sun sensor 6 exterior sensor box 1 Short circuit 142 Sun sensor 7 exterior sensor box 1 Short circuit 143 Sun sensor 8 exterior sensor box 1 Short circuit 144 Sun sensor 9 exterior sensor box 2 Not connected 145 Sun sensor 10 exterior sensor box 2 Not connected 146 Sun sensor 11 exterior sensor box 2 Not connected 147 Sun sensor 12 exterior sensor box 2 Not connected 148 Sun sensor 9 exterior sensor box 2 Short circuit 149 Sun sensor 10 exterior sensor box 2 Short circuit 150 Sun sensor 11 exterior sensor box 2 Short circuit 151 Sun sensor 12 exterior sensor box 2 Short circuit
2. Insert the RS232 serial communication cable to a serial port on the PC Make sure that the RS485 serial communication cable is connected to the building controller see installation guide and that the building controller is powered and properly installed Start the animeo IB Operating software The software will ask you which communication port you are using on the PC see picture below Select the one which you connected to the RS232 cable to and press OK Used port COMI Cancel Ok Copyright 2003 SOMFY SAS All rights reserved IDDN FR 001 270044 000 D P 2003 000 31500 Somfy SAS capital 20 000 000 Euros RCS Bonneville 303 970 230 Changes can be done by Somfy SAS without notice Page 17 C The building controller will now start to upload its stored parameters The communicating window will be shown during the uploading picture below Communicating Pap SLs Select language time format and units see 6 5 3 2 to 6 5 3 4 Select picture of the building see 6 5 2 2 If you already have a project file p followed by e g 20 that indicates the version of the software here version 2 0 In the future version 3 1 for example will be called 31 please continue to 4 2 3 otherwise go to 4 2 4 4 2 3 You have a project file Open the supplied project file p20 from the menu Open Project The download button will now turn red indicating that there are changes in the
3. C Solar heating HVAC When active the zone acts to gain heat in combination with the HVAC system by for exemple move sun protection to 0 position Maintain heat When active the zone acts to preserve heat by for exemple move sun protection to 100 position Ventilation cooling HVAC When active the zone acts for natural ventilation in combination with the HVAC system for exemple by opening windows or night cooling Zone Synergy This function will activate the interior sun protection when the linked exterior sun protectionis locked for exemple by wind Sun This function becomes active if sun intensity is above the threshold The zone takes its programmed position fixed or suntracking Non critical system error When active a minor error has occured These errors will not impact the security of the system and will not execute any action Thid is just an indication To identify the error refer to ch 10 error codes Copyright 2003 SOMFY SAS All rights reserved IDDN FR 001 270044 000 D P 2003 000 31500 Somfy SAS capital 20 000 000 Euros RCS Bonneville 303 970 230 Changes can be done by Somfy SAS without notice Page 33 6 6 1 2 Explanation of the priorities It is important that the concept of priority is fully understood Depending on the your installation of sensors inputs some functions are not available they turn grey on the status table Concerning the availabl
4. Angle By an angle o degree we mean that the slats are in horizontal position An angle of 9odegrees means that they E g7 A Ke Casei E ij Pi gg fy la are in vertical position Angles are only used for venetian blinds HVAC Heating Ventilation and Air Condition control system Security functions Functions related to avoiding damage of the end product or safety of the user A security command will lock the end product in a 0 or 100 position Local control in not possible in this mode Non security functions Functions not related to avoiding damage of the end product or safety of the user After a non security command you can control locally if local control is allowed Automatic functions Functions set up with the PC and activated without manual interaction Manual functions Zones functions set up with the PC Controls menu in the navigator in opposition to automatic functions Local functions Functions set up with the local switches and active only at a motor controller level Copyright 2003 SOMFY SAS All rights reserved IDDN FR 001 270044 000 D P 2003 000 31500 Somfy SAS capital 20 000 000 Euros RCS Bonneville 303 970 230 Changes can be done by Somfy SAS without notice Page 5 2 Introduction to animeo 2 1 Unique features in animeo amp The animeo IB Operating software Instead of using small LCD s and multifunction pushbuttons we use a standard PC computer
5. one functions visualised yu Sensors state visualised yu Select functions 6 6 1 1 Select sensors 6 6 1 3 Maintenance monitoring YES Select Log l identify a proble No Select system Select error NO NO fem wiring operationat 1 Check the PC communication trouble shooting YES 2 Check the system wiring trouble shooting Generate or order at NO v least a c20 file YES Load c20 or open p20 v There is a problem Check in step 2 and if not solved go to step 1 y click on the flowchart for full view Copyright 2003 SOMFY SAS All rights reserved IDDN FR 001 270044 000 D P 2003 000 31500 Somfy SAS capital 20 000 000 Euros RCS Bonneville 303 970 230 Changes can be done by Somfy SAS without notice End of the configuration No Tror indication inactive YES Page 63 Start of the configuration il nb al Have installation is operation em wiring operationat D Basic parameters adjusted NO Adjust check in menu Settings No Select SETTINGS Building Pe Zone settings e Local functions functions adjusted NO NO NO NO NO See 6 6 3 5 See 6 6 3 3 See 6 6 3 4 Select CONTROL NO gt Zone operat
6. 152 Inside temperature sensor 1 interior sensor box 1 Not connected 153 Inside temperature sensor 1 interior sensor box 1 Short circuit 154 Inside temperature sensor 2 interior sensor box 1 Not connected 155 Inside temperature sensor 2 interior sensor box 1 Short circuit 156 Interior sensor box 1 error 157 Inside temperature sensor 3 interior sensor box 2 Not connected 158 Inside temperature sensor 3 interior sensor box 2 Short circuit 159 Inside temperature sensor 4 interior sensor box 2 Not connected 160 Inside temperature sensor 4 interior sensor box 2 Short circuit 161 Interior sensor box 2 error Copyright 2003 SOMFY SAS All rights reserved IDDN FR 001 270044 000 D P 2003 000 31500 Somfy SAS capital 20 000 000 Euros RCS Bonneville 303 970 230 Changes can be done by Somfy SAS without notice Page 73 C 11 Legal information 11 1 Copyright information The animeo Software and the information of this manual are protected by copyright Except as specifically permitted the animeo Software or this manual in part or in all may not be distributed or reproduced by any means or in any form without Somfy SAS prior written permission The animeo Software is registered with the Agency for the Protection of Programs under the Inter Deposit Digital Number IDDN IDDN FR 001 270044 000 D P 2003 000 31500 11 2 Trademarks Information Somfy Somfy logo animeo Powered by Somfy l
7. 2003 SOMFY SAS All rights reserved IDDN FR 001 270044 000 D P 2003 000 31500 Somfy SAS capital 20 000 000 Euros RCS Bonneville 303 970 230 Changes can be done by Somfy SAS without notice Page 69 Sun function off delay Max value 180min Min value 1min Is open slats function enabled Max value True Min value False Is zone synergy enabled Max value True Min value False Zone synergy linked zone Max value 16 Min value Number of cycles 133 Is two speed motor used Max value Min value Max value Min value True False 134 Two speed motor speed difference 100 0 Max value Min value 135 Is automatic mode enabled Max value True Min value False 157 Sun tracking maximum angle position Max value 100 Min value 0 158 Sun tracking minimum angle position Max value 90 Min value 0 159 Sun tracking sun entrance depth Max value 65535mm Min value 0mm 160 Screen Shutter height Max value 65535mm Min value Omm 161 Password 162 Project name 163 Supplier name 164 Supplier contact 165 Supplier phone 166 Supplier email 167 Configurer name 169 Project latitude Max value Min value 170 Help web address 171 Service email recipients 172 Is service email used 173 Error email recipients Max value Min value 174 Is error email used Max value True M
8. C Owner s manual PC software 2 0 animeo IB Operating software Rev 2 0 Language English Date 2003 10 15 File Somfy animeo Operating PC Software 2 0 Owners manual English Changes can be made without notice Copyright 2003 SOMFY SAS All rights reserved IDDN FR 001 270044 000 D P 2003 000 31500 Somfy SAS capital 20 000 000 Euros RCS Bonneville 303 970 230 Table of Contents Table of Contents 1 Welcome to animeo 1 1 General note 1 2 Terminology 2 Introduction to animeo 2 1 Unique features in animeo 2 2 Product overview 2 2 1 Building controller 2 2 2 Outside sensor box 2 2 3 Inside sensor box 2 2 4 Motor controller 2 2 4 1 Motor controller extension box 2 2 5 RS485 adapter 2 2 6 animeo Operating software 2 3 Technical Background 2 3 1 Architecture 2 3 2 How functions are handled in the system 2 3 3 IB protocol 2 4 Specification of the system 2 4 1 Howto decide the number of zones in a system 2 4 2 Howto choose and install sensors 2 4 3 What type of switches to use 3 PC requirements 4 Installation of the operating PC software 4 1 Configure Windows for best performance 4 2 Configure animeo Operating PC Software 4 2 1 animeo system automatic start up sequence 4 2 2 Configure step by step 4 2 3 You have a project file 4 2 4 You do not have a project file but a configuration file 4 2 5 Working offline 5 Installing optional functionality 5 1 Install
9. and a 110 or 230V power supply Below the different devices are explained Note Separate data sheets are available for each device a n va UIL AN wy LE NYY ANY S d a mt a re a pe Sneed isan 2 AA Ha f a 2 Ma LaLa Copyright 2003 SOMFY SAS All rights reserved IDDN FR 001 270044 000 D P 2003 000 31500 Somfy SAS capital 20 000 000 Euros RCS Bonneville 303 970 230 Changes can be done by Somfy SAS without notice Page 6 2 2 1 Building controller This unit is the brain of the system All decisions and automatic commands are carried out here Each building controller can control a maximum of 8 different zones If you need to control even more zones an additional building controller can be added as an extension 16 zones is the maximum number of zones the system can handle To configure the hardware e g number of zones make settings e g wind thresholds and make manual commands for a PC computer running the animeo IB Operating software is required The building controller communicates with the PC and sensor boxes over RS485 and with the motor controllers via the own protocol gt IB Data Building controller Number of Zones 1 Number of Alarm input 0 Number of HVAC cold 0 0 1 1 Number of HVAC heat Number of Key building lock input Number of Error relay output Data Building controller Extension Number
10. 3 Motor controller Copyright 2003 SOMFY SAS All rights reserved IDDN FR 001 270044 000 D P 2003 000 31500 Somfy SAS capital 20 000 000 Euros RCS Bonneville 303 970 230 Changes can be done by Somfy SAS without notice Page 2 9 Parameter list 66 10 Error codes 72 10 1 Major errors 72 10 2 Non critical system errors 73 11 Legal information 74 11 1 Copyright information 74 11 2 Trademarks Information 74 11 3 animeo software licence agreement 74 11 3 1 Definitions 75 11 3 2 License Grant 75 11 3 3 Restrictions 75 11 3 4 Ownership 75 11 3 5 Copies of the Software 76 11 3 6 Term and Termination 76 11 3 6 1 Term 76 11 3 6 2 Termination 76 11 3 7 Consideration 76 11 3 8 Export Requirements 76 11 3 9 Audit 76 11 3 10 Warranty 76 11 3 11 Limitation of Liability 7 11 3 12 Confidentiality 77 11 3 13 Miscellaneous 77 12 Contacts 78 Copyright 2003 SOMFY SAS All rights reserved IDDN FR 001 270044 000 D P 2003 000 31500 Somfy SAS capital 20 000 000 Euros RCS Bonneville 303 970 230 Changes can be done by Somfy SAS without notice Page 3 C Thanks for buying the animeo control system for sun protection and windows We advise you to carefully study this manual to get the full benefit of the system This manual does not only contain information needed to install and run the program it also explains all functions and possibilities in detail 1 Welcome to animeo If you consider yourself an expert in
11. SOMFY SAS All rights reserved IDDN FR 001 270044 000 D P 2003 000 31500 Somfy SAS capital 20 000 000 Euros RCS Bonneville 303 970 230 Changes can be done by Somfy SAS without notice Page 66 Wind sensor allocation outside sensor box 2 31 Sun sensor allocation outside sensor box 1 32 Sun sensor allocation outside sensor box 2 33 Is major alarm function enabled Max value True Min value False 34 Major alarm active position Max value 100 Min value 0 35 Is Building lock active Max value True Min value False 36 Is zone lock active Max value True Min value False 37 Is wind function enabled Max value True Min value False 38 Wind threshold Max value 30m s Min value 1m s 39 Wind on delay Max value 15min Min value 1min 40 Wind off delay Max value 30min Min value 1min 41 Is wind direction function enabled Max value True Min value False 42 Wind direction threshold Max value 30m s Min value 1m s 43 Wind direction protected angle start Max value 63 gt 1 5 degrees Min value 0 44 Wind direction protected angle end Max value 126 gt 9 45 degress Min value 9 45 Is rain function enabled Max value True Min value False 46 Rain Snow on delay Max value 250sec Min value 1sec 47 Rain Snow off delay Max value 60min Min value 1min 48 Is snow function enabled Max value True Min value False 49 Is frost
12. and no energy functions are executed And vice versa outside the user comfort time energy functions are executed and the user cannot control the end products locally Zone 1 Zone 1 000 100 200 200 400 SCO amp 00 700 8 Hi 1000 11 00 1200 1200 1400 1500 1602 1700 1800 1300 21 00 2200 2300 000 Drag rouse on areia to set active tere penod User conferi val be evubled charg active bre wgon Ouside the active fine regiona wet combat wile daabled ard syatom it ene savino V Performance timer without local control Same as performance with local control but the end products can not be controlled locally even during user comfort time V Performance Presence detector with local control This mode can be selected only when presence detectors have been installed This mode works as the performance timer with local control Instead of having a time span in which the system is in user comfort mode user comfort time starts when the presence detectors detect that a person is present in the room In this mode the user comfort for each room is controlled independently The room will be reset to execute all functions when the timeout has expired For example in the winter the weather is cold outside but sunny The sun is very low In the office the user closes the sun blinds to avoid glare But when the user leaves the room the presence detector knows that there is nobody in the office and executes the energy saving functions e g orders the sun b
13. at 50 avenue du Nouveau Monde 74300 Cluses France You means your company or organisation Documentation means all the documents related to and distributed with the animeo Software Software means the animeo Software and its Documentation The Software shall be dedicated to work only with Somfy products Content means the trademarks logo designs legends symbols labels copyright and other proprietary notices included in the Software 11 3 2 License Grant Somfy grants to You a non exclusive and non transferable license to use store load install execute and display the Software 11 3 3 Restrictions You shall not remove modify or create any derivate works of the Software including translation e disassemble decompile reverse engineer or otherwise attempt to derive the source code for the Software unless required for interoperability remove or alter the Content of the Software make the Software available in any manner to any third party for use in the third party s business operations redistribute sell rent lease sublicense or otherwise transfer rights to the Software to any third party 11 3 4 Ownership The Software and its Content are protected by copyright and other intellectual property laws and by international treaties Somfy retains all ownership and intellectual property rights related to the Software and its Content You acknowledge such ownership and intellectual property rights and sh
14. can be done by Somfy SAS without notice Page 20 C 6 Working with animeo IB Operating software This chapter explains the various menus and windows in the software Below you find an overview picture We will now go in detail through the software and all its possibilities and functions gle Arira Bi Deserti Felre Eey Boia AME rim reo hen wel rai Can miray rage ler Fipilem wim ian Ea se Pata M Copa RIN balle E Coi Zoe E pE d Emm M H i na i veni ne MEI p j io Mc eine onae i cycle 25 ea a 6 1 General information It is useful to keep the following information in mind Since animeo is a modular and flexible system regarding to functionality the number and type of sensors and number of zones may differ depending on your system This manual describes all of animeo s possibilities It is possible to work with the software even if no building controller is connected This allows for example for the possibility of creating a project even if you have no access to the building controller for later download training and demonstration Functions vary depending on the type of end product in a zone For example wind functions are disabled for interior Venetian blinds The animeo IB Operating software supports different languages which can be changed in runtime All pictures and printed screens in this user manual are in English Copyright 2003 SOMFY SAS All rights reserved
15. commonly used part of the software so read it carefully This chapter describes all possibilities in detail Using the building overview 6 5 2 2 in parallel with the Navigator often simplifies your job in giving you a perfect overview of the building You navigate in the Navigator by pressing the title bar 1 and its sub icon 2 See the pictures below for a full overview of all different possibilities in the navigator A quick overview of the navigator is given below Status Contains real time information of functions and sensors Functions Here you can have an overview of the status of all functions active or inactive for each zone Sensors Here you visualize installed sensors values and get information if a sensor is damaged Control Contains functions to give manual commands Manual command Here you give manual and intermediate commands for each zone Locking command Here you lock the building or any zone Settings Contains forms to make all settings Functions Here you make all settings for the building and for each zone Energy mode Here you make settings related to energy and comfort Log Contains logs of the total system o i System Here you can monitor log from the sensors functions and the user Error Here you can monitor errors that might have occurred in system Because animeo IB is a modular and flexible system functionality number and type
16. done by Somfy SAS without notice Page 52 6 6 3 5 Operational mode Detailed information about Energy saving Standard and performance timer modes is given in the following 1 After you have made changes we suggest you press the save button The saved file is used as a quick backup 3 2 Use the building overview 6 5 2 2 during your setting work It helps you to obtain a quick overview Energy savings and comfort modes Timer local conlrol DI z 1 Netth East O 2 East 3 South East 4 South O S South vest O amp West CD 7 Noth West LI amp Neth Explanation of the content 1 Select Zone to edit 2 Data of the selected zone 3 Operational mode selector 4 Select function to edit Functions available vary depending on the operational mode Operational modes explanation Operational modes are used to automatically optimize the user environment minimize energy consumption or a combination of both The functions vary between windows and sun protection The choice of the operational mode also impacts the functions you can set mainly local control and energy saving functions A priority order has been implemented in the system to organize the order in which the functions are executed This order can be viewed in Status functions in the navigator and is explained in detail in 6 6 1 Status Please refer to this chapter You will also find a function grading with explanations The different possible modes and
17. done when the PC is online Parameters Select month to view logged data Parameter log Print log Clear all clear the parameter log permanently A pop up has been added to prevent you from clearing unintentionaly 5 Update click to update parameter log 2 to obtain latest parameters FWN Clear 4 will permanently remove all parameter logs Copyright 2003 SOMFY SAS All rights reserved IDDN FR 001 270044 000 D P 2003 000 31500 Somfy SAS capital 20 000 000 Euros RCS Bonneville 303 970 230 Changes can be done by Somfy SAS without notice Page 60 Function explanation 6 6 4 1 3 Functions 20030203140056 2003 02 08 14 00 55 2003 02 08 140057 2003 02 03 14 00 57 2003 02 03 14 00 57 2008 02 03 14 00 57 2003 02 03 14 00 57 2003 02 03 14 00 57 2003 02 03 14 00 57 2003 02 03 14 00 57 2003 02 03 14 00 57 2003 02 03 140057 2003 02 03 14 01 31 2003 02 03 14 01 48 2003 02 03 14 02 45 2003 02 08 14 04 02 2003 02 03 14 04 02 2003 02 08 14 04 02 2003 02 03 1404 02 2003 02 08 1404 02 2003 02 03 14 04 02 2003 02 08 1404 02 2003 02 03 14 04 03 2003 02 08 14 04 03 DIPALI NA 14 NA NR In this window you can view all functions which were activated and inactivated in the past Logging is only done when the PC is online Parameters FWN gt Select month to view logged data Function log Print Clear all clear function log permanently A pop up has been added to
18. function enabled Max value True Min value False 50 Frost threshold Max value 5 Celsius Min value 40 Celsius 51 Frost on delay Max value 10min Min value 1min 52 Frost off delay Max value 60min Min value 1min 53 Is building timer enabled Max value True Min value False 54 Building timer 0 start time Max value 1439min 3 23 59 Min value 0 gt 00 00 55 Building timer 0 stop time Max value 1439min gt 23 59 Min value 0 gt 00 00 56 Building timer 100 start time Max value 1439min gt 23 59 Min value 0 gt 00 00 57 Building timer 100 stop time Max value 1439min gt 23 59 Min value 0 gt 00 00 58 Is zone timer enabled Max value True Min value False 59 Zone timer 1 start time Max value 1439min gt 23 59 Min value 0 gt 00 00 Copyright 2003 SOMFY SAS All rights reserved IDDN FR 001 270044 000 D P 2003 000 31500 Somfy SAS capital 20 000 000 Euros RCS Bonneville 303 970 230 Changes can be done by Somfy SAS without notice Page 67 60 Zone timer 1 stop time Max value 1439min gt 23 59 Min value 0 gt 00 00 61 Zone timer 1 action 0 0 1 100 2 IP1 3 1IP2 62 Zone timer 2 start time Max value 1439min gt 23 59 Min value 0 gt 00 00 63 Zone timer 2 stop time Max value 1439min gt 23 59 Min value 0 gt 00 00 64 Zone timer 2 action 0 0 1 100 2 1P1 3 IP2 65 Is reset building enabled Max value True Min v
19. language later e g by remote access 6 5 3 3 Time format Here you choose the time format the software should display i e 12 or 24 hours format 6 5 3 4 Units Here you set the units you want to use The selected unit is indicated with a check mark see picture below EZ Somfy Animeo Yisualization Test project File Project Settings Tools Help Wind speed Temperature ne i The units are divided into 6 5 3 4 1 Temperature Celsius and Fahrenheit are available 6 5 3 4 2 Wind m s km h and mph are available 6 5 3 4 3 Length mm and inch are available Copyright 2003 SOMFY SAS All rights reserved IDDN FR 001 270044 000 D P 2003 000 31500 Somfy SAS capital 20 000 000 Euros RCS Bonneville 303 970 230 Changes can be done by Somfy SAS without notice Page 25 6 5 4 Tools In this menu you find functions needed to build local switch groups replace or add motor controllers and special communication features Detailed information about the menu function Tools is given in the following Perhaps you will not configure local groups at this stage so you may prefer to return 6 5 4 1 Motor controller This menu contains functions regarding switch configuration add replace hardware and forced communication 6 5 4 1 1 Switch and Presence detector configuration The building controller must be online when you make Switch and presence detector configuration Add Update or replace motor controller and Forced commu
20. mode Maga Position 100 90 Interior Venetian blind Control mode RSI Position Exterior Venetian blind Control mode RG Posio DR Exterior Venetian blind Major Alarm Major Alarm Position Download changes m Online em Traffic Total number of cycles 137 09 02 AM 2003 09 08 Copyright 2003 SOMFY SAS All rights reserved IDDN FR 001 270044 000 D P 2003 000 31500 Somfy SAS capital 20 000 000 Euros RCS Bonneville 303 970 230 Changes can be done by Somfy SAS without notice Page 12 2 3 3 IB protocol The building controller communicates with the motor controller via 4 wires Three of these wires are used to give up down and stop commands in a traditional way This function is more or less the same as any other centralized controller on the market The fourth wire is unique and allows for several interesting possibilities This wire is used for sending data in a digital uni directional format to the motor controllers The advantage is that the animeo system is sending positions and angles to the motor controllers instead of just time which was the traditional way in the past Why is this an advantage It is explqined in the example below Any end product in an animeo system can be programmed with its own unique running time very useful when you have different heights of windows in a zone This is not possible in other centralized systems where you need a physical zone for all
21. of Zones 1 8 This may vary depending on configuration 2 2 2 Outside sensor box This sensor box makes it possible for you to connect external sensors e g sun and wind sensors and also a radio time synchronization module DCF Depending on the number of sensors required in a project you can connect up to two outside sensor boxes Note For a system to function outside sensor box must be connected Data Outside sensor box Standard Number of Sun sensors that can be connected 0 8 Number of Wind sensors that can be connected 0 2 Number of Wind direction sensor that can be connected 0 1 Number of Outside temperature sensor that can be connected 0 1 Number of Rain sensor that can be connected 0 1 Number of DCF module that can be connected 0 1 Data Outside sensor box Optional Number of Sun sensors that can be connected Number of Wind sensors that can be connected This may vary depending on configuration Copyright 2003 SOMFY SAS All rights reserved IDDN FR 001 270044 000 D P 2003 000 31500 Somfy SAS capital 20 000 000 Euros RCS Bonneville 303 970 230 Changes can be done by Somfy SAS without notice Page 7 2 2 3 Inside sensor box On this box you connect internal sensors Depending on the number of sensors needed up to two internal sensor boxes can be connected in a system You will also find inputs to externally control or lock any zone via a key switch There is one input for each
22. prevent you from clearing uninten tionaly Update click to update parameter log 2 to obtain latest function changes Clear 4 will permanently remove all function logs Copyright 2003 SOMFY SAS All rights reserved IDDN FR 001 270044 000 D P 2003 000 31500 Somfy SAS capital 20 000 000 Euros RCS Bonneville 303 970 230 Changes can be done by Somfy SAS without notice Page 61 6 6 4 2 Error In log error all possible errors over time are viewed Logging is only made when the PC is online All Errors are explained in 10 Occured 4 Wind direction sensor exterior sensor box 1 No signal Occured 4 Wind direction sensor exterior sensor box 1 No signal 2003 09 12 10 58 38 Occured 4 Wind direction sensor exterior sensor box 1 No signal 2003 09 12 10 58 24 Cleared 4 Wind direction sensor exterior sensor box 1 No signal 2003 09 12 10 57 22 Occured 4 Wind direction sensor exterior sensor box 1 No signal 2003 09 02 09 20 22 Cleared 4 Wind direction sensor exterior sensor box 1 No signal 2003 09 02 09 14 52 Occured 4 Wind direction sensor exterior sensor box 1 No signal Function explanation In this window you can view all Errors that might have occurred in the system in the past Parameters Select month to view logged data Error log Print log Clear all clear function log permanently A pop up has been added to prevent you from clearing uninten tionaly
23. system Nw Press the download button to start the download The communicating window will be shown during the download When the download is finished the communication window will disappear and the download button turns grey The building controller is now updated as a result of the project file If you perhaps want to build local switch groups please study 6 5 4 1 1 Save your project as a backup 4 2 4 You do not have a project file but a configuration file Load your configuration file Make all settings required to your system see chapter 6 for detailed information Download your settings to the building controller by pressing the download button If you perhaps want to build local switch groups please study 6 5 4 1 1 amp Save your project as a backup After a while you might like to make some changes of certain parameters so that the system fulfills your own unique requirements In this case see chapter 6 Copyright 2003 SOMFY SAS All rights reserved IDDN FR 001 270044 000 D P 2003 000 31500 Somfy SAS capital 20 000 000 Euros RCS Bonneville 303 970 230 Changes can be done by Somfy SAS without notice Page 18 4 2 5 Working offline Working off line means that the PC is not connected to the system You can make settings to parameters when you are working offline If you connect the building controller when animeo Operating software is running and the settings differ betw
24. the whole building in 0 position When the lock function is active it is impossible both automatically for the building controller and manually for the user to order the end products to any other position they are totally locked in 0 position This function is very useful during window cleaning or facade work Zone Lack aze ese aze n Eza __Recsssontito__ mz L aoe azs Hates mza eann mone 8 _Devebpessiekwing Explanation of the contents 1 Lock buttons for individual zones 2 Zone aliases 3 Lock button for the entire building all zones Example how to give a locking command W Click 1 2 to lock a zone The diode on the button lights up when active Y Click 3 to lock the entire building The diode on the button lights up when active To turn off an active locking command just click the active button The diode on the button turns off to confirm that the command is inactive Note For the priority degree of this function see 6 6 1 2 Copyright 2003 SOMFY SAS All rights reserved IDDN FR 001 270044 000 D P 2003 000 31500 Somfy SAS capital 20 000 000 Euros RCS Bonneville 303 970 230 Changes can be done by Somfy SAS without notice Page 37 6 6 3 Settings In Settings menu you make all settings of parameters The menu is divided in Functions and Operational mode settings When any change is made you must download the changes to the building controller When any change is made t
25. to become the subject of a claim to infringement of a patent trade secret copyright or other intellectual property rights This termination shall not raise any right whatsoever to your benefit 11 3 7 Consideration This license agreement is granted to be used by You together with the Somfy products purchased by You Therefore this license agreement is granted with no itemized consideration 11 3 8 Export Requirements You shall not export or re export or allow the export or re export of the Software or any copy in violation of any applicable laws and regulations 11 3 9 Audit Upon 45 days written notice Somfy may audit your use of the Software You agree to cooperate with Somfy s audit and provide Somfy with reasonable assistance and access information 11 3 10 Warranty Somfy warrants that the Software will operate appropriately as described in the Documentation provided you shall comply with the PC requirements mentioned in the owner s manuals for the Software the PC on which the Software is run shall be exclusively dedicated to the Software no other program shall be run or installed on the PC SOMFY DOES NOT WARRANT THAT THE SOFTWARE WILL PERFORM ERROR FREE OR UNINTERRUPTED OR THAT SOMFY WILL CORRECT ALL SOFTWARE ERRORS TO THE EXTENT PERMITTED BY LAW THESE WARRANTIES ARE EXCLUSIVE AND THERE ARE NO OTHER EXPRESS OR IMPLIED WARRANTIES OR CONDITIONS INCLUDING WARRANTIES OR CONDITIONS OR MERCHANTABILITY SATISFACTORY Q
26. 0 Somfy SAS capital 20 000 000 Euros RCS Bonneville 303 970 230 Changes can be done by Somfy SAS without notice Page 58 6 6 4 LOG The log is divided into System logs sensors parameter changes and function and Error logs The log function is for the registration of data The sensor log is for the registration of major sensor data every 5 minutes Parameter sensor error is for the registration of events This chapter explains the log function in detail Logging is only made when the PC is online 6 6 4 1 System In log system all Sensor data Parameter changes and Function activities over time are viewed You select what to view by clicking the tabs on the top 6 6 4 1 1 Sensors In this window you can view all sensor values since the start of the project The sampling rate is five minutes The logged value is the average value during sampling If there is no change since the last logged value no sampling will be logged i i i PAE 33002 120000 am 33002 120200 pm Time Parameters 1 Select the sensor type to view in the log diagram 3 All sensors are accessible 2 Select month to view logged data 3 Log diagram 4 Sensor selection 5 Scroll function click this icon and then drag the X and Y axes for scrolling 6 Zoom function click this icon and then drag the X and Y axes for zooming 7 Zoom out click this icon to zoom out 8 Zoom in click this icon to zoom in 9 Zoom box click th
27. 0 000 Euros RCS Bonneville 303 970 230 Changes can be done by Somfy SAS without notice Page 41 C 6 6 3 4 2 Wind direction See picture 6 6 3 4 in parallel when reading this chapter Function explanation If you have a wind direction sensor installed you have access to this smart function When the standard wind function 6 6 3 4 1 act irrespective of wind direction it results in the following if the wind comes from the west and exceeds the threshold 3 your sun protection on the east facade will be locked in a secure position which is probably not necessary With the wind direction sensor you can set a specific protected angle for each zone 8 9 with its own wind threshold 7 In practice this means that the wind speed threshold 3 is active outside the protected angle and acts as turbulence protection while the wind direction threshold 7 will be active inside your protected angle 8 9 The wind threshold 3 should normally be set 25 higher than wind direction threshold 7 This means that a zone will only be locked when a dangerous wind hits the facade or when there is turbulence You gain more sun protection and you are still protected from wind damage The wind direction threshold 7 cannot be set higher than the wind speed threshold 3 The wind direction function cannot be read from the wind sensor 2 At least one sensor must be allocated to have access to the wind direction function A wind sensor should al
28. 00 Somfy SAS capital 20 000 000 Euros RCS Bonneville 303 970 230 Changes can be done by Somfy SAS without notice Page 26 t Configure a zone A Select the desired configuration 1 B Select Whole zone access mode 3 C Select the zone 5 D Click Download button 7 Make a note of your configuration as it is not saved in the system t Configure the entire project A Select the desired configuration 1 B Select Entire project access mode 4 C Click Download button 7 Make a note of your configuration as it is not saved in the system The following switch configurations are possible Configuration Comment 1 1 1 1 Each motor have it is own switch Motor 1 is controlled by Switch 1 and so on 2 1 1 Switches 1 and 2 control Motor 1 and 2 as a group Motor 3 is controlled by Switch 3 and Motor 4 is controlled by Switch 4 3 1 Switches 1 2 and 3 control Motor 1 2 and 3 as a group Motor 4 is controlled by Switch 4 1 2 1 Switches 2 and 3 control Motor 2 and 3 as a group Motor 1 is controlled by Switch 1 and Motor 4 is controlled by Switch 4 2 2 Switches 1 and 2 control Motor 1 and 2 as a group Switches 3 and 4 control Motor 3 and 4 as a group 1 3 Switches 2 3 and 4 control Motor 2 3 and 4 as a group Motor 1 is controlled by Switch 1 1 1 2 Switches 3 and 4 control Motor 3 and 4 as a group Motor 1 is controlled by Switch 1 and Motor 2 is controlled by Switch 2 4 Switches
29. 003 000 31500 Somfy SAS capital 20 000 000 Euros RCS Bonneville 303 970 230 Changes can be done by Somfy SAS without notice Page 39 i gt 4 6 6 3 3 3 Building timer Click the Timer button 8 see picture at 6 6 3 3 to open the Building timer window Function explanation The building timer allows you to set for each weekday one 0 and one 100 locking command 9 The resolution of the timer is 15 minutes Time periods cannot overlap 15 during a day Two practical examples of usage of the central timer are shown in the following Y Lock sun protection in 0 position to avoid vandalizing of the end products during night V Lock rolling shutter in 100 position during night as a burglar protection Parameters VY Add time period Click and hold the mouse button down on the desired day and direction bar 10 Drag left or right to set the time period Release the mouse button The active time is shown on the right 11 on the ruler indicated by two red lines 12 Y Adjust time period Click and hold the mouse button down one of the ends of the desired time period 13 and drag in desired direction Release the mouse button V Move time period Click and hold the mouse button down the desired time period 13 and drag the mouse in desired direction Release the mouse button V Remove time period Click and hold the mouse button down one of the ends of the period 13 and drag so the time lines disappear You can also rem
30. 1 2 3 and 4 control Motor 1 2 3 and 4 as a group Copyright 2003 SOMFY SAS All rights reserved IDDN FR 001 270044 000 D P 2003 000 31500 Somfy SAS capital 20 000 000 Euros RCS Bonneville 303 970 230 Changes can be done by Somfy SAS without notice Page 27 6 5 4 1 2 Add update or replace When replacing or adding a motor controller the motor controller must be programmed with its zone s unique data such as running times intermediate positions type of end product and switch function To do this continue as follows A Select the desired switch configuration 1 B Select the zone the motor controller is connected to 2 C Enter the motor controller Id number 3 you find the Id on the motor controller s housing D Click Download button 4 and note your configuration if has not been saved in the system dv Download will overwrite all local configurations for example intermediate positions 6 5 4 2 Forced communication These functions are used to upload and download all settings This compliments the Download button and can be useful during the testing of a system 6 5 4 2 1 Upload all from building controller This function is used to return to the latest settings stored in the building controller 6 5 4 2 2 Download all to building controller This function submits all settings to the building controller from the PC Copyright 2003 SOMFY SAS All rights reserved IDDN FR 001 270044 000 D
31. 5 Update click to update error log 2 to obtain the most recent errors FWN a B Clear 4 will permanently remove all function logs Copyright 2003 SOMFY SAS All rights reserved IDDN FR 001 270044 000 D P 2003 000 31500 Somfy SAS capital 20 000 000 Euros RCS Bonneville 303 970 230 Changes can be done by Somfy SAS without notice Page 62 6 7 Check if configuration complete Q Now you have reviewed all the functions and possibilities of the animeo IB operating software The following flowchart provides you with a checklist to make sure all settings and steps have been done This also gives you a total overview of the operating software from wiring to monitoring Have you checked Tye installation is operational YES Basic parameters adjusted YES Settings adjusted YES Start of the configuration NO NO Adjust check in menu Settings NO Select SETTINGS NO NO NO Operational mod YES Building ES Zone settings ES i ES NO See 6 6 3 5 See 6 6 3 3 See 6 6 3 4 See 6 5 4 NO S elect CONTROL Control chosen YES w e one operation adjusted vuo YES Biilding amp zone Toek _YES adjusted yu Manual command Locking command Lt NO YES Select STATUS
32. CS Bonneville 303 970 230 Changes can be done by Somfy SAS without notice Page 14 4 Installation of the operating PC software Installing the software on the computer is very easy Please just follow the steps below There are two installation files on the CD one for each software setup Somfy Animeo IB System Software exe setup Somfy Animeo IB Operating Software exe Make sure that your computer meets the PC requirements Close any other application running on your computer amp Place the CD in the CD ROM reader and run the setup Somfy Animeo IB Operating Software exe file Follow the on screen instructions For information see 4 1 Restart your computer if this is not done automatically When your computer is restarted animeo IB Operating software shortcut should now appear on your monitor Conditions of use for the animeo software are defined in the licence agreement supplied on the CR Rom The installation download and use of the animeo software are conditionned by the acceptance of these terms The installation software has now created an animeo IB Operating software folder on the Start bar a shortcut to your desktop 4 1 Configure Windows for best performance Please make the following settings in Windows If help is needed refer to Windows help or contact your system administrator Energy settings for the PC When animeo IB continously communicates between the PC and the Bu
33. FR 001 270044 000 D P 2003 000 31500 Somfy SAS capital 20 000 000 Euros RCS Bonneville 303 970 230 Changes can be done by Somfy SAS without notice Page 71 10 Error codes Below follows a complete error list 10 1 Major errors Error nr Definition 0 Outside temperature sensor Not connected 1 Outside temperature sensor Short circuit 2 Wind sensor 1 exterior sensor box 1 Timeout no signal in 12hours 3 Wind sensor 2 exterior sensor box 1 Timeout no signal in 12hours 4 Wind direction sensor exterior sensor box 1 No signal 5 Wind direction sensor exterior sensor box 1 Overload 6 Rain sensor error 7 Major alarm input error 8 Exterior sensor box 1 error 9 Wind sensor 3 exterior sensor box 2 Timeout no signal in 12hours 10 Wind sensor 4 exterior sensor box 2 Timeout no signal in 12hours 11 Exterior sensor box 2 error 12 Building controller EEPROM data error 13 Building controller hardware error 20 PC debug major error 72 Building controller debug major error 73 Building controller slave module error T4 Time lost error 127 Major error Copyright 2003 SOMFY SAS All rights reserved IDDN FR 001 270044 000 D P 2003 000 31500 Somfy SAS capital 20 000 000 Euros RCS Bonneville 303 970 230 Changes can be done by Somfy SAS without notice Page 72 10 2 Non critical system errors
34. IDDN FR 001 270044 000 D P 2003 000 31500 Somfy SAS capital 20 000 000 Euros RCS Bonneville 303 970 230 Changes can be done by Somfy SAS without notice Page 21 6 2 Sensor bar In the sensor bar you can view all sensor values input and output status in real time For most sensors the exact value is shown both in figures and in graphics For sensors and inputs that can only be on or off e g Alarm and Rain its corresponding diode will be lit when active and vice versa If a sensor or input is not used it will be greyed out as HVAC Heat in the picture below Wind spoed Sun intensity Temperature System info Lome Ltr EES I eh Wind direction Snow MI Fo 20 RIN an si Quid Eno RIN iici MM PRESI TERRE x Sm E i M gt x J The following sensors inputs and outputs can be shown Wind direction sensor Wind speed sensor if more than one sensor is installed only the highest value is shown amp Sun intensity sensor if more than one sensor is installed only the highest value is shown Inside temperature sensor if more than one sensor is installed only the highest value is shown Outside temperature sensor Rain sensor e Snow Alarm input Error indication External building switch input central switch connected to the Building Controller External zone switch input switch input from the inside sensor box will be lit if a switch is active HVAC h
35. P 2003 000 31500 Somfy SAS capital 20 000 000 Euros RCS Bonneville 303 970 230 Changes can be done by Somfy SAS without notice Page 28 6 5 5 Help In this menu you find all help files needed to be able to run the software The following information is about the menu function Help 6 5 5 1 Help file Here you open the Help files for the software In fact the document you are reading right now You can also open the help file by pressing Fi B The Help file requires that Adobe Acrobat is installed 6 5 5 2 Visit homepage Only when a web address is pre configured will this menu option be available If you click Visit homepage your web browser will be started and automatically open the pre configured web address B You need access to the Internet and a web browser to be able to use this function 6 5 5 3 About When open About you get information about the animeo IB Operating software and the building controller software versions You will only get the building controller software version if you are online By clicking system info you will get access to your PC s system information Copyright 2003 SOMFY SAS All rights reserved IDDN FR 001 270044 000 D P 2003 000 31500 Somfy SAS capital 20 000 000 Euros RCS Bonneville 303 970 230 Changes can be done by Somfy SAS without notice Page 29 6 6 Navigator In the Navigator you make all settings of parameters and give commands This is probably the most
36. UALITY AND FITNESS FOR A PARTICULAR PURPOSE Version 1 0 9 July 2003 Copyright 2003 SOMFY SAS All rights reserved IDDN FR 001 270044 000 D P 2003 000 31500 Somfy SAS capital 20 000 000 Euros RCS Bonneville 303 970 230 Changes can be done by Somfy SAS without notice Page 76 C 11 3 11 Limitation of Liability IN NO EVENT SHALL SOMFY BE LIABLE FOR ANY INDIRECT INCIDENTAL SPECIAL PUNITIVE OR CONSEQUENTIAL DAMAGES UNDER THIS LICENSE AGREEMENT OR ANY LOSS OF PROFITS REVENUE DATA OR DATA USE 11 3 12 Confidentiality The Software and its Contents are confidential Therefore You shall not disclose the Software and its Contents to any third party during the execution of this license agreement and after its termination 11 3 13 Miscellaneous If any of the provisions of this license agreement are judged to be illegal or unenforceable the continuation in full force and effect of the remaining provisions of this license agreement shall not invalidate or otherwise be rendered ineffective This license agreement is the sole and entire agreement between You and Somfy with respect to its subject matter and is deemed to be made under and shall be construed in accordance with the laws of France without giving effect to the conflict of laws principles thereof All disputes in connection with the present license agreement including any question regarding its existence validity or termination shall be settled by the competen
37. a free serial RS232 communication port Recommended Intel Pentiumy 2 Ghz 256Mb internal memory 4oMb free hard disc space True color graphic card 17 monitor I CD ROM Mouse and Keyboard Windows 2000 Adobe Acrobat Reader anda free serial RS232 communication port Optional Access to email server and the Internet is required for email functionality For remoteaccess functionality you need access to the Internet Note 1 To be able to use the email functions the computer must be connected to an email server and have a configured email account in Outlook Express We do not recommend modem connections animeo IB Operating software uses this account to send emails An email account is not needed by the animeo IB Operating system as it does not receive emails Note 2 To be able to use Remote Access functions the computer must be connected to the Internet and have a permanent IP address The software Symantec PC Anywhere must also be installed and configured We recommend a minimum communication speed of 512k to have a correctly running system Modem connections are not recommended Remote Access functionality is an optional function Note 3 To ensure the functionality of the system the PC should be dedicated to animeo No other program should be running simultaneously on the PC Copyright 2003 SOMFY SAS All rights reserved IDDN FR 001 270044 000 D P 2003 000 31500 Somfy SAS capital 20 000 000 Euros R
38. ain heat active position Max value 100 Min value 0 101 Maintain heat sun threshold Max value 50klux Min value 1klux 102 Maintain heat on delay Max value 10min Min value 1min 103 Maintain heat off delay Max value 30min Min value 1min 111 Is ventilation cooling HVAC enabled Max value True Min value False 112 Ventilation cooling HVAC inside temperature Max value 25 Celsius threshold Min value 15 Celsius 113 Ventilation cooling HVAC outside Max value 25 Celsius temperature threshold Min value 5 Celsius 114 Ventilation cooling HVAC on delay Max value 10min Min value 1min 115 Ventilation cooling HVAC off delay Max value 30min Min value 1min 116 Ventilation cooling HVAC active position Max value 100 Min value 0 118 Is sun function enabled Max value True Min value False 119 Sun function on threshold Max value 50klux Min value 1klux 120 Sun function on delay Max value 10min Min value 1min 121 Is suntracking enabled Max value True Min value False 122 Sun function fixed active position Max value 100 Min value 0 Sun function fixed active angle Max value 90 Min value 90 Sun tracking position angle table Max value 100 or Min value 90 or Sun tracking switch times Max value 1439min gt 23 59 Min value 0 gt 00 00 Sun function off threshold Max value 50klux Min value 1klux Copyright
39. all not take any action to jeopardize limit or interfere in any manner with Somfy s ownership of or rights with respect to the Software and its Content This license agreement confers You no title or ownership in the Software and in its Content and is nota sale of any rights in the Software and in its Content Amendments to this Documentation can be made by Somfy without prior notice Version 1 0 9 July 2003 Copyright 2003 SOMFY SAS All rights reserved IDDN FR 001 270044 000 D P 2003 000 31500 Somfy SAS capital 20 000 000 Euros RCS Bonneville 303 970 230 Changes can be done by Somfy SAS without notice Page 75 C 11 3 5 Copies of the Software You are authorized to make copies of the Software for archival purposes or when copying is an essential step in the authorized use of the Software You are authorized to make one copy of the Software for backup purposes when your system is inoperative 11 3 6 Term and Termination 11 3 6 1 Term This license agreement is effective from the date on which You download the Software You may terminate this license agreement at any time by destroying the Software 11 3 6 2 Termination Without prejudice to any other rights this license agreement shall terminate automatically and without notice if You fail to comply with any term or condition of it Somfy may terminate this license agreement by notice immediately should the Software become or in the opinion of Somfy is likely
40. alue False 66 Reset building time Max value 1439min gt 23 59 Min value 0 gt 00 00 67 Is reset manual to automatic local control Max value True enabled Min value False 68 Is reset manual to automatic local control time Max value True 1 enabled Min value False 69 Reset manual to automatic local control Max value 1439min gt 23 59 enabled time 1 Min value 0 gt 00 00 70 Is reset manual to automatic local control time Max value True 2 enabled Min value False 71 Reset manual to automatic local control Max value 1439min gt 23 59 enabled time 2 Min value 0 gt 00 00 72 Is reset manual to automatic local control time Max value True 3 enabled Min value False 73 Reset manual to automatic local control Max value 1439min gt 23 59 enabled time 3 Min value 0 gt 00 00 74 Intermediate position 1 Max value 100 Min value 0 75 Intermediate angle 1 Max value 90 Min value 0 76 Intermediate position 2 Max value 100 Min value 0 77 Intermediate angle 2 Max value 90 Min value 0 80 Energy mode O Energy mode without local control 1 Standard with local control 2 Standard without local control 3 Performance timer with local control 4 Performance timer without local control 5 Presence detector with local control 6 Presence detector without local control 81 User comfort start time Max value 1439min gt 23 59 Min value Omin gt 00 00 82 User comfort stop time Ma
41. ation of Email functionality 5 2 Installation of Remote Access functionality 6 Working with animeo IB Operating software 6 1 General information 6 2 Sensor bar 6 3 Download 6 4 Communication Copyright 2003 SOMFY SAS All rights reserved IDDN FR 001 270044 000 D P 2003 000 31500 Somfy SAS capital 20 000 000 Euros RCS Bonneville 303 970 230 Changes can be done by Somfy SAS without notice 223003431 aa AuE F 12 Page 1 6 5 Menu 6 5 1 File 6 5 1 1 Open project 6 5 1 2 Save project 6 5 1 3 Load Configuration 6 5 1 4 Print project info 6 5 1 5 Exit 6 5 2 Project 6 5 2 1 Pre configuration 6 5 2 2 Building overview 6 5 2 3 Hardware overview 6 5 3 Settings 6 5 3 1 COM port selection 6 5 3 2 Language 6 5 3 3 Time format 6 5 3 4 Units 6 5 4 Tools 6 5 4 1 Motor controller 6 5 4 2 Forced communication 6 5 5 Help 6 5 5 1 Help file 6 5 5 2 Visit homepage 6 5 5 3 About 6 6 Navigator 6 6 1 Status 6 6 1 1 Functions 6 6 1 2 Explanation of the priorities 6 6 1 3 Sensors 6 6 2 Control 6 6 2 1 Manual command 6 6 2 2 Locking command 6 6 3 Settings 6 6 3 1 Login 6 6 3 2 Copy settings 6 6 3 3 Building functions 6 6 3 4 Zone functions 6 6 3 5 Operational mode 6 6 4 LOG 6 6 4 1 System 6 6 4 2 Error 6 7 Check if configuration complete 7 Expand the system with more zones sensors or functions 7 1 More sensors 7 2 More zones 7 3 Others 8 Replace or add hardware 8 1 Building controller 8 2 PC computer 8
42. ble for windows The sun function is used to delegate the end products to specific position When sun intensity exceeds the On threshold 2 the end products will go down When sun intensity is lower than the Off threshold 4 the end products will be sent to 0 position The position the end products take when the sun function is active is either a fixed position 8 or a calculated position depending on the sun angle see Suntracking 6 6 3 4 4 for more detailed information The Zone Synergy function 9 is explained in 6 6 3 4 5 Parameters 1 Enable Disable function 2 Threshold ON the sun intensity needed to activate the sun function A normal value is 20 25klux 3 On delay the time the sun intensity must exceed the On threshold 2 before is activated the sun func tion A normal value is 2min 4 Threshold Off the threshold the sun must be under to deactivate the sun function A normal value is 15 20klux 5 Off delay the time the sun intensity must be lower than the Off threshold 4 before deactivating the sun function A normal value is 20 60min 6 Sun sensor allocation at least one sensor must be chosen Allocate sun sensors for your zone by clicking the checkbox If more than one sensor is selected the sensor with the highest sun intensity value will be used 7 Open slats after 10 of Off delay this function is only available for venetian blinds Instead of having the slats closed when the sun is f
43. computers and sun protection systems we advise you to at least read the chapter 6 This document is both the product user manual and help file for the PC software From time to time you will find the picture to the left in the manual This indicates tip and trick information that can be useful When you will find this picture to the left in the manual it indicates very important information 1 1 General note The animeo IB Operating software supports different languages which can be changed in runtime We have covered as many different scenarios and hardware combinations as possible to make this manual as informative and user friendly as possible Note animeo IB Operating and System software should not be run simultaneously when it is not possible to share a COM Port Copyright 2003 SOMFY SAS All rights reserved IDDN FR 001 270044 000 D P 2003 000 31500 Somfy SAS capital 20 000 000 Euros RCS Bonneville 303 970 230 Changes can be done by Somfy SAS without notice Page 4 C 1 2 Terminology Here follows some terminology that is important to understand the system correctly End products With end products we mean any product that a motor is controlling Examples Windows and awnings Position When talking about position we use 0 and 100 to mean Blinds o fully up 100 down Windows 0 closed 100 open Awnings 0 retracted 100 extended The 0 position is also called a Secure position
44. d 5 Position when active normally 100 Note For the priority degree of this function see 6 6 1 2 Copyright 2003 SOMFY SAS All rights reserved IDDN FR 001 270044 000 D P 2003 000 31500 Somfy SAS capital 20 000 000 Euros RCS Bonneville 303 970 230 Changes can be done by Somfy SAS without notice Page 57 6 6 3 5 5 Ventilation cooling HVAC controlled This function is accessible for windows only Operational mode Performance Timer local control 10 West Garage building v Window opened outdoors Ventilation Cooling Ventilation c HVAC controlled 1 Enabled IF the HVAC cold input is active then move to the given position io Copy between zones Function explanation Parameters 1 Enable Disable function safety measure Note For the priority degree of this function see 6 6 1 2 2 The position the end product takes when the function is active Position 2 100 24 When the HVAC cold input is active the windows will take position 2 This function is used to ventilate the building This also lowers the cooling costs Normally this function is used outside working hours Note As soon as the HVAC cold input is active the window takes the position In switching from active to non active there is a one minute delay This avoid damaging the window motor so the delays acts as an motor Copyright 2003 SOMFY SAS All rights reserved IDDN FR 001 270044 000 D P 2003 000 3150
45. different window heights animeo will then automatically become a more economic and user friendly system A motor controller knows both its connected motors exact position and running time So when the system commands a zone to go for example to position 40 each end product will be positioned to 40 of its window height The advantage of sending positions is also used for functions like sun tracking intermediate positions and building local groups for switches and or remotes 2 4 Specification of the system This chapter deals with topics that are good to keep in mind when a system is being specified 2 4 1 How to decide the number of zones in a system Please discuss this topic with experts before selecting but the basic rules are One zone per weather direction facade If there is for example surrounding buildings that will shadow parts of the facade you might need to make a more detailed segmentation If the building is very high or wide it could be good to split up many zones when the wind situation varies You cannot combine motor controllers with and without presence detectors installed in a zone There should only be one type of end product per zone e g when the wind resistance varies according to end products As mentioned you can have different running times on each individual end product This means that a zone can contain the same type of end products but with different heights But keep in mind Y lf the di
46. e functions they are listed in a priority order The functions are classified in 6 blocks that will be activated at different levels according to the chosen operational mode For more information about operational mode see 6 6 3 5 Zone 1 4 Control mode Control mode AGN Control mode AGN Control mode AGI Position Position 100 90 Position Lozo Position Cz Exterior Venetian blind Interior Venetian blind Exterior Venetian blind Exterior Venetian blind Information Major Alarm Ma n Security functions PC Building Lock 0 PC Zone Lock 0 A Active Key Building Lock 0 e Key Zone Lock O 7 _ Inactive or Erro E Disse Disabled Frost Building Timer Building Timer Building Timer Key Building 100 Key Building 100 Key Building 100 Non security functions E Disabled T Not used in manual mode Non Critical System Error i tem Error Non Critical System Error Non Critic tem Error 1 Security functions ensure the safety of persons and products when generated A security order will block the end product in 0 or 100 position Local control 6 is not possible PC command manual switch Manual orders are given by the PC Control menu in the navigator or man ually on the product Non security timer functions Energy functions corresponding to the chosen operational mode Sun and non critical system error functions listed as the lowest priorities Local Switch control overrides non security fu
47. eat input HVAC cold input An even more detailed sensor and input information is available in Navigator Status Sensor 6 6 1 3 6 3 Download As soon as you make any changes in the settings this button turns RED 1 to indicate that a download is required To download changes to the building controller press the button and the download starts During download a communication window is visible When the download is completed the button turns GREY 2 When working offline the button will be disabled 3 Commands given from the software e g manual or blocking commands will be sent directly to the building controller without needing to press the download button i 4 Download changes Download changes 1 Need to download 2 No need to download 3 Disabled Copyright 2003 SOMFY SAS All rights reserved IDDN FR 001 270044 000 D P 2003 000 31500 Somfy SAS capital 20 000 000 Euros RCS Bonneville 303 970 230 Changes can be done by Somfy SAS without notice Page 22 6 4 Communication When a building controller is online the green online diode lights up When there is communication between the PC and the Building controller the yellow traffic diode flashes ge Urine m Trattic 6 5 Menu The menu contains the following functions and subfunctions in total including email File Project Settings Tools Email Help File Project Settings Tools Help x Pre Com port Open project contieura
48. een the PC and the building controller the software will ask you if you want to use the settings in the building controller or in the PC Animeo IB Operating Software e x If you choose to use the settings in the PC the download button will tight up red to indicate that you must download the PC s settings to the building controller Copyright 2003 SOMFY SAS All rights reserved IDDN FR 001 270044 000 D P 2003 000 31500 Somfy SAS capital 20 000 000 Euros RCS Bonneville 303 970 230 Changes can be done by Somfy SAS without notice Page 19 5 Installing optional functionality 5 1 Installation of Email functionality Configure an Email account and network connection in Outlook Express animeo should use Outlook express for email functionnality Make sure that Send messages immediately is enabled in Outlook Express Make sure that Warn me when other applications try to send mail at the same time as me is disabled in Outlook Express 5 2 Installation of Remote Access functionality For Remote access installation and configuration refer to Symantech PC Anywhere 10 5 manual The functions in this chapter are optional There are also special technical requirements for these functions to work please study chapter PC requirements carefully Copyright 2003 SOMFY SAS All rights reserved IDDN FR 001 270044 000 D P 2003 000 31500 Somfy SAS capital 20 000 000 Euros RCS Bonneville 303 970 230 Changes
49. ered from Somfy How to load a c20 file is found in 6 5 1 3 If an existing zone in the system has a change of end product in the new configuration file or if the direction of the zone has changed for more tan 20 degrees the software will automatically ask you if you want to use default settings or the existing settings for these zones See picture below Default Yalues In the configuration loaded products have been ries i at a a sales cate aed Group 1 Reception Group 2 Gym Group 3 Conference room Group 4 Development department Group 7 Support Department 7 3 Others To add new functions for example a change of alias proceed as explained in 7 1 Copyright 2003 SOMFY SAS All rights reserved IDDN FR 001 270044 000 D P 2003 000 31500 Somfy SAS capital 20 000 000 Euros RCS Bonneville 303 970 230 Changes can be done by Somfy SAS without notice Page 64 C 8 Replace or add hardware If you replace or add building controller PC computer or a motor controller please study this chapter 8 1 Building controller Replace Do as follows 1 Save your project 2 Replace the building controller 3 Open your saved project and download it to the new building controller 4 Local settings in the motor controller units need to be reset because they may have been overwritten Add Do as follows 1 Add the building controller extension 2 Load the new configuration file See 6 5 1 for more i
50. fference of heights is too great it might affects for example the wind resistance Y The suntracking will not work properly for some type of end products if the window height varies Y For venetian blinds this is not a problem but could be for e g awnings Use rather too many than too few zones 2 4 2 How to choose and install sensors Which sensors to use is linked to the type of functions required The physical installation of sensors is linked to how the zones are divided and built If there is for example no surrounding buildings that are shadowing the building normally all sensors are installed at the highest point of the building If a facade is divided vertically you might need to place some sensors on the facade 2 4 3 What type of switches to use To be able to use the intermediate functions the local switches must work as follows You must either be able to press both up and down pushbuttons at the same time or the switch must have a stop button Somfy can supply switches with these features Copyright 2003 SOMFY SAS All rights reserved IDDN FR 001 270044 000 D P 2003 000 31500 Somfy SAS capital 20 000 000 Euros RCS Bonneville 303 970 230 Changes can be done by Somfy SAS without notice Page 13 3 PC requirements Minimum Intel Pentium2 500 Mhz 128Mb internal memory 4oMb free hard disc space True color graphic card 17 monitor CD ROM Mouse and Keyboard Windows 2000 Adobe Acrobat Reader and
51. fic name an alias Functions that are not used for a specific end product will not be visible in the software An example could be that wind and precipitation functions are disabled for internal venetian blinds You can also import any picture of the building to get immediate access to a good overview of the system The system works even when the PC is not connected but you will not be able to make any settings or give any commands by PC A Somfy Animeo IB Operating Software P gt 18 x File Project Settings Tools Help Wind direction Wind speed Sun intensity Temperature System info KI EL Rein IT Ext Building ME TE Snow km Ext Zone pesi da A EIN Eno M cHe Outside i Alarm ii HVAC Cole Download changes Online em Traffic Total number of cycles 124 08 45 AM 2003 09 08 Copyright 2003 SOMFY SAS All rights reserved IDDN FR 001 270044 000 D P 2003 000 31500 Somfy SAS capital 20 000 000 Euros RCS Bonneville 303 970 230 Changes can be done by Somfy SAS without notice Page 11 2 3 Technical Background It is always an advantage to know a little about how a system works technically Here follows some basic topics that are useful to know 2 3 1 Architecture animeo is a centralized system using IB protocol but it works in many ways like a de centralized system such as EIB or LONWorks The great advantage of animeo is that it contains many of the de centralized functionality strengt
52. fy SAS without notice Page 49 6 6 3 4 10 Zone timer Open the zone timer first by enabling the function and then click the timer button Zone Tener Zone 1 Reception gt 0 00 y 2o a 4 600 7 ve 900 Rane ae Wor 10 taotao stra ao 000 515 to 0815 7 45 to 34 15 230100815 1815402345 045 to 0045 14 151 2015 oo NN iez cg Tre 2 u 0 Saturday imei RIME NSO HS a a ins Sunday feet Aio ____________ 35000095 Active iol Po oa Cick and drag mouse on timeline to set active time regiona Double dick on timeline to toggle betresen the actions below Function explanation The zone weekly timer allows you to set two individual commands 5 for each weekday 0 100 Intermediate position 1 or 2 Time periods cannot overlap 4 during a day The resolution of the timer is 15 minutes The zone timer is not a locking command Note You can change the time format see 6 5 3 3 Parameters VY Add time period Click and hold the mouse button down on the desired day and direction bar 1 Drag left or right to set the time period Release the mouse button The active time is shown on the right 6 on the ruler indicated by two red lines 7 Y Select command Double click a time region to select a command 2 Each double click will select next command 5 Y Adjust time period Click and hold the mouse button down one end of the desired time period 2 and drag in desired direction Release the
53. have made some changes the software will ask you if you want to save your project to avoid losing any data Copyright 2003 SOMFY SAS All rights reserved IDDN FR 001 270044 000 D P 2003 000 31500 Somfy SAS capital 20 000 000 Euros RCS Bonneville 303 970 230 Changes can be done by Somfy SAS without notice Page 23 6 5 2 Project This menu contains information regarding pre configuration building and hardware overview The following contains detailed information regarding the menu function Project 6 5 2 1 Pre configuration Here you find all information of pre configured data in your system e g number of zones sensors and aliases Gives you a detailed product and system overview Project Information and Pre Configuration 1 2 3 4 5 6 7 8 9 10 n 12 Service email An email is automatically generated and sent to pre defined recipients when a zone has exceeded the pre defined service interval This is useful to automatically ensure that the end product obtains the required service Error email An email is automatically generated and sent to pre defined recipients when a critical error has occurred This is useful to automatically ensure that the system is working perfectly 6 5 2 2 Building overview Here you get access to an overview picture of your building This is useful when you need to give commands or make settings a perfect overview that speeds up your work You have to make the pict
54. he download button turns red indicating that download is required To download just click the download button See 6 3 for further information 6 6 3 1 Login To avoid any settings are made unintentionally or by unauthorized persons you will be asked for a Password to be able to enter the setting windows Somfy supplies you this Password After you exit the settings windows or when no actions are made for a period exceeding 15 minutes there is a timeout and you will have to log in again This feature both speeds up and secures the system Login Expert Settings 6 6 3 2 Copy settings To speed up your work you can copy settings between zones Select the source and target zone and the function s you want to copy and then click the Copy button The type of functions you can copy depends on the zone s end products When you perform a copy you might need to change some specific settings for the target zone Examples could be sensor allocation wind direction protected angle and motor running time The copy function will save you a lot of time when you configure a system Copy functions fi Reception End product Energy mode Copyright 2003 SOMFY SAS All rights reserved IDDN FR 001 270044 000 D P 2003 000 31500 Somfy SAS capital 20 000 000 Euros RCS Bonneville 303 970 230 Changes can be done by Somfy SAS without notice Page 38 6 6 3 3 Building functions In this form you have settings that are common for all zo
55. hes can be programmed from the PC to build local groups within a motor controller This means for example that switch 1 can control motor1 2 and 3 in a local group Switches can also be connected in parallel even between different motor controllers This is useful to be able to build big local groups Ergonomics There is built in running time in the motor controller so you do not have to press the switch continuously to control the motor The way this exactly works varies depending on the type of sun protection Intermediate positions You can also program a specific position for a motor an intermediate position The intermediate position is very useful to build local scenarios e g meeting To program this position just run the motor to the desired position and press both up and down pushbutton at the same time for at least 2 seconds The motor will rapidly run down and up to confirm that your intermediate position is programmed To recall the position locally just press both up and down pushbutton and the motor will directly take up the programmed position The intermediate position can also be recalled from the PC In this case each motor in a zone will take its own unique Intermediate position User Feedback performance mode When a local command is given the motor controller understands that you want to take over the control of your local end product The motor controller will stop acknowledging non security functions This
56. hs The PC sensor boxes and building controller use bi directional communication data is transferred in both directions Communication from the building controller to the motor controllers is uni directional data is only transferred in one direction This means that it is not possible to get feedback from the motor controllers Each zone in animeo has its own physical cabling Settings e g wind threshold are common for all motors in a zone Each zone can use any sensor 2 3 2 How functions are handled in the system Functions are divided into two different types security and non security Security functions refer to functiosn that are crucial for the safety of the user e g major alarm or to ensure that the end products will not be damaged e g wind The other functions are non security functions e g sun AII functions are prioritized If more than one function is active at the same time only the function with the highest priority will be executed In the animeo IB Operating software you can easily get an overview of which functions are active and their priority A Somfy Animeo IB Operating Software Status Functions i le xl File Project Settings Tools Help Wind direction Wind speed Sun intensity Temperature System info nw NE ome E Rain Ext Buling RI Ala Inside Snow TTT Ext Zone 7 wW E Di 2 2 Evo Mi VAC Hest Ez i HVAC Col IT Control
57. ilding controller it is important that the PC does not enter an Energy saving sleep mode If this occurs the communication will be broken and there will be a risk of software failure Proceed as follows a Open the Power Options by clicking Start Settings Control Panel Power Options b Select Power Scheme Always on c Click on Apply Font size The animeo IB software has been designed with a user friendly graphic interface A graphic interface is designed for a specific font size animeo uses standard Windows font size If you use different font size the software will work correctly but the interface may be corrupted Proceed as follows a Open the Display by clicking on Start Settings Control Panel Display b Select the Settings tab c Click on the Advanced button d Select Small fonts 96dpi in the Display panel e Click on Apply f Restart Windows Copyright 2003 SOMFY SAS All rights reserved IDDN FR 001 270044 000 D P 2003 000 31500 Somfy SAS capital 20 000 000 Euros RCS Bonneville 303 970 230 Changes can be done by Somfy SAS without notice Page 15 Appearance The animeo IB software has been designed with a user friendly graphic interface A graphic interface is designed for a specific appearance scheme animeo uses the Windows standard If you use another appearance scheme the software will work correctly but the interface may be corrupted Proceed as follows a Open the Di
58. ille 303 970 230 Changes can be done by Somfy SAS without notice Page 51 6 6 3 4 12 Running and Tilting time Wind Sun Ran Snow and Frost Intermediate Positions Zone Timer Major Alam Running and Tik Time Time 100 gt 0 151 2 Time 0 gt 100 148 2 Time 0 gt 90 oa Abemate th speed 20 ad Function explanation To be able to position the end products the system must know the needed time for the end products to move from position 100 0 and vice versa 1 2 This is also necessary for slat tilting the time needed to tilt the slats from 0 90 3 There are also motors for venetian blinds that have one speed when tilting and another when going up and down i e a two speed motor When a two speed motor is used you must set the tilt speed difference of the full speed as a percentage between the two different motor speeds 4 Note Setting the running and tilting times is the first thing to do Parameters 1 Time needed in seconds to move the end product from 100 0 1 2 Time needed in seconds to move the end product from 0 100 2 3 Time needed to tilt the slats from 0 90 3 4 Speed difference between lifting and tilting for two speed motors 4 Note For more information on running and tilting time see 1 2 Copyright 2003 SOMFY SAS All rights reserved IDDN FR 001 270044 000 D P 2003 000 31500 Somfy SAS capital 20 000 000 Euros RCS Bonneville 303 970 230 Changes can be
59. in value False 175 Wind unit 0 m s 1 km h 2 mph 176 Temperature unit 0 Celsius 1 Fahrenheit 177 Time format 178 Length unit 0 24h 1 12h 0 mm 1 Inch 180 Selected language 181 Zone direction Max value 71 gt 1 5 degrees Min value 0 182 Zone alias 183 Wind sensor alias outside sensor box 1 184 Wind sensor alias outside sensor box 2 185 Sun sensor alias outside sensor box 1 186 Sun sensor alias outside sensor box 2 187 Wind direction alias 188 Inside temperature sensor alias inside sensor box 1 189 Inside temperature sensor alias inside sensor box 2 190 Outside temperature sensor alias Copyright 2003 SOMFY SAS All rights reserved IDDN FR 001 270044 000 D P 2003 000 31500 Somfy SAS capital 20 000 000 Euros RCS Bonneville 303 970 230 Changes can be done by Somfy SAS without notice Page 70 191 Rain sensor alias 192 Maximum possible wind threshold Max value 30m s Min value 1m s 193 Are presence detectors used Max value True Min value False 194 Is local control used Max value True Min value False 195 Is HVAC heat input used Max value True Min value False 196 Is HVAC cold input used Max value True Min value False 197 Number of cycles between service Max value 65535 Min value 0 198 Is major alarm input used Max value True Min value False Copyright 2003 SOMFY SAS All rights reserved IDDN
60. ing in Position and Tilt 6 6 3 4 3 and click the button to the right The system calculates three angles positions 4 5 7 and two switching times 6 8 per month This means that the end products will change position angle automatically three times per day and change positions angles every month If you want to fine tune the calculated positions linked to your own requirements you can manually adjust the result of the calculation 4 8 The diagram shows 1 the sun curve per month An exact sun angle per hour can be displayed by clicking the icon 2 on the left and then month 3 A red line will appear in the diagram By dragging the line horizontally you will get the time hour minute and sun angle on the pop up window The functionality of the sun tracking varies depending on the type of end product VY Facade awning You can set a maximum allowed position 1 When making a calculation no position will be greater than the allowed position This is useful in obtaining a certain view through the window Copyright 2003 SOMFY SAS All rights reserved IDDN FR 001 270044 000 D P 2003 000 31500 Somfy SAS capital 20 000 000 Euros RCS Bonneville 303 970 230 Changes can be done by Somfy SAS without notice Page 44 WY Venetian blind For venetian blinds you can set a maximum allowed angle 11 When a calculation is made no angle will be greater than the allowed angle This is useful for example to always allow a certain vie
61. ing lock 0 When activated all the end products move to 0 Often use for window cleaning PC Zone lock 0 When activated all the end products in a zone move to 0 Often use for window cleaning Key building lock 0 This function becomes active if you give an order for more than 1 2 s on the central switch input on the building controller In this case all the end products move to 0 Often use for installation in which no permanent PC is used Key Zone lock 0 This function becomes active if you give an order for more than 1 2 s on the inside sensor box inputs In this case all the end products move to 0 Often use for installation in which no permanent PC is used Major error When active all the end products take their secure positions To identify the error please refer to 8 error codes Wind speed Wind alarm generated when if wind speed exceeds the defined threshold In this case all end products in a zone take their secure position Wind direction Wind direction generated if wind speed is above the threshold and wind direction is within the defined angle In this case all end products in a zone take their secure position Key building lock 100 Snow Snow alarm generated if temperature is beside 4 degrees and rain is detected In this case all end products in a zone take their secure position Frost Frost alarm generated if temperature is below the threshold In this ca
62. ion 1 Check the PC communication trouble shooting 2 Check the system wiring trouble shooting Settings adjusted Operational mod YES adjusted YES YES Do you have a c20 or a p20 Generate or order at least a c20 file YES Load c20 or open p20 Error indication inactive Control chosen Building amp zone d adjusted adjusted There is a problem Check NO NO in step 2 and if not NO Select STATUS solved go to step 1 _ __oi Zone functions visualised NO Select functions 6 6 1 1 Select LOG YES YES Status visualized Sensors state visualised NO Select sensors 6 6 1 3 YES Maintenance monitoring Get information NO Select system dentify a proble Select error End of the configuration 7 Expandthe system with more zones sensors or functions In some cases this results in adding hardware In this case study chapter 8 When you have added for example more zones then these zones must be configured Please study 6 6 3 7 1 More sensors To expand the system with more sensors you need to load a new c20 configuration file This software can be ordered from Somfy How to load a c20 file is found in 6 5 1 3 7 2 More zones To expand the system with more sensors you need to load a new c20 configuration file This file can be ord
63. ion is not available for interior end products Parameters 1 Enable Disable function 2 Wind sensor allocation All installed sensors are shown in the list Allocate the wind sensors for the selected zone by clicking the checkbox At least one sensor must be allocated 3 Wind threshold the wind speed required to activate the wind function The possible maximum threshold 3 that can be set depends on the type of end product and pre configuration This ensures that too high a threshold is set unintentionally 4 On delay gt the time for the wind speed to exceed the threshold 3 before activating wind function 5 Off delay the time for the wind speed to be less than the threshold 3 before deactivating the wind function Examples of settings wind speed parameters The following examples are suggestions The impact of wind speed of an end product varies between brands and dimesions Please contact the end product supplier for further advice End product type Wind speed On delay Off Delay m s Km h Mph Fagade awning Screen 10 36 20 1 sec 5 15min External venetian blind 15 54 33 1 sec 5 15min Folding arm awning 8 29 18 1 sec 5 15min Rolling shutter 20 72 4h 1 sec 5 15min Window 10 36 20 1 sec 5 15min Note For the priority degree of this function see 6 6 1 2 Copyright 2003 SOMFY SAS All rights reserved IDDN FR 001 270044 000 D P 2003 000 31500 Somfy SAS capital 20 00
64. is icon and then mark the area in the log diagram 3 you want to zoom Turn of the function by clicking the icon again 10 Cursor Select the sensor 4 and then the cursor icon 10 a line will appear in the log diagram 3 By drag ging the line horizontally you will get the sensor value time and date in a pop up window Turn off the function by clicking the icon again n Print log diagram 3 12 Clear All sensor logs will be cleared permanently We advise you not to do this as the log is useful when fine tuning or trouble shooting the system A pop up has been added to prevent you from clearing unintentionally 13 Update click to update log diagram 3 to obtain default dimensions and latest sensor values Copyright 2003 SOMFY SAS All rights reserved IDDN FR 001 270044 000 D P 2003 000 31500 Somfy SAS capital 20 000 000 Euros RCS Bonneville 303 970 230 Changes can be done by Somfy SAS without notice Page 59 6 6 4 1 2 Parameters All parameters are explained in 9 RLO TECTO NO Value lunga lib GROUP _TIMER_END1 Index 1 Zone 1 Value False changed to True 2002 1003 081357 GROUP TIMER_POS_SELECTI index 1 Zone 1 Value 0 changed to 450 2002 10 09 08 13 57 GROUP_TIMER_START2 index 1 Zona 1 Yaue0 changsd lo 990 Function explanation In this window you can view changes of settings made by the user over time This is a technical log which is used by expert users Logging is only
65. itches inputs Number of window contact inputs Number of remote control IR modules inputs P F F F Copyright 2003 SOMFY SAS All rights reserved IDDN FR 001 270044 000 D P 2003 000 31500 Somfy SAS capital 20 000 000 Euros RCS Bonneville 303 970 230 Changes can be done by Somfy SAS without notice Page 10 2 2 5 RS485 adapter This unit is an interface that converts the system s protocol RS485 to a protocol that the PC can handle RS232 RS485 is used to communicate over long distances 2 2 6 animeo Operating software The software is the link between the system and the user From the software you make all settings of parameters e g wind and sun threshold and delays configuration of switches manual and locking commands The software also visualizes the status of all functions sensors and position of end products There is also a builtin log that tracks all sensor values actions errors and changes of any parameter If the PC is connected to the Internet and or a mail server the software can be remotely controlled and can automatically generate emails when servicing is required or when an error occurs The software is developed for international usage so any unit e g wind m s km h and mph and a various number of languages e g English German and French can be chosen and changed in runtime To make the software as user friendly as possible e g all sensors and zones can be given a speci
66. le the frost function it may cause damage to the end products Copyright 2003 SOMFY SAS All rights reserved IDDN FR 001 270044 000 D P 2003 000 31500 Somfy SAS capital 20 000 000 Euros RCS Bonneville 303 970 230 Changes can be done by Somfy SAS without notice Page 48 Function explanation An intermediate position is a pre programmed position and also an angle if the end product is a venetian blind that can be recalled from either the software or from the local switches Intermediate position 2 is unique for the animeo IB Operating software and can not be recalled or programmed by the local switches Intermediate position 1 can locally be individually programmed and recalled by the local switches From the animeo IB Operating software you can recall each individual intermediate position but only program one common position and angle if the end product is a venetian blind for the whole zone If you program the intermediate position 1 from the animeo IB Operating software all locally programmed positions will be overwritten Parameters 1 Set intermediate Position 1 2 Set intermediate Angle 1 3 Set intermediate Position 2 4 Set the intermediate Angle 2 Note For the priority degree of this function see 6 6 1 2 Copyright 2003 SOMFY SAS All rights reserved IDDN FR 001 270044 000 D P 2003 000 31500 Somfy SAS capital 20 000 000 Euros RCS Bonneville 303 970 230 Changes can be done by Som
67. linds to go up for solar heating The user has also the possibility to set a position locally If he does so the programmed position is recalled each time the presence a person is detected Copyright 2003 SOMFY SAS All rights reserved IDDN FR 001 270044 000 D P 2003 000 31500 Somfy SAS capital 20 000 000 Euros RCS Bonneville 303 970 230 Changes can be done by Somfy SAS without notice Page 54 UV Presence detector without local control Same as Performance presence detector with local control but the end products can not be controlled locally This means that if a person is present in the room energy saving functions will not be executed in that room Depending on the operational mode you have chosen functions are executed or not executed In the modes below none of the energy functions are executed Standard Performance timer with local control in user comfort time Performance timer without local control in user comfort time Performance presence detector with local control when presence is detected in the room Performance presence detector without local control when presence is detected in the room In the modes below local switch control functionality is disabled e Standard without local control Energy saving Performance timer with local control non comfort time Performance timer without local control Performance presence detector with local control when no presence is detected in the ro
68. lowed angle or position Screen Roller shutter height Sun entrance depth Picture of end product NSBGVaANaVFWN D gt _ Fw Copyright 2003 SOMFY SAS All rights reserved IDDN FR 001 270044 000 D P 2003 000 31500 Somfy SAS capital 20 000 000 Euros RCS Bonneville 303 970 230 Changes can be done by Somfy SAS without notice Page 45 6 6 3 4 5 Zone Synergy This function is only available for interior solar protection Link intese sun protection to exterior If the exterior zone is blocked by wind or snow this interior zone wal be activated by the linked exterior zone sun ana ee Function explanation This function will activate the interior sun protection when the linked exterior sun protection is locked by security function To have use of this function there must be both interior and exterior sun protection in the same facade The Zone synergy function ensures that either an exterior or interior sun protection is active to optimize room comfort In the practice the Zone Synergy function adopts the sun function from the linked external sun protection and activates the interior sun protection when the exterior is blocked in 0 position You can set specific Position and Tilt angle 4 for the internal zone see 6 6 3 4 3 and 6 6 3 4 4 for more information e The way to use the function is simple Y Enable the function by clicking Zone Synergy check box 1 V Select the zone to be linked
69. mouse button The active time is shown on the right 6 on the ruler indicated by two red lines 7 V Move time period Click and hold the mouse button down the desired time period 2 and drag the mouse in desired direction Release the mouse button The active time is shown on the right 6 on the ruler indicated by two red lines 7 V Remove time period Click and hold the mouse button down one end of the period 2 and drag so the timeline disappears You can also remove all time periods by clicking the Clear 3 button Note For the priority degree of this function see 6 6 1 2 Copyright 2003 SOMFY SAS All rights reserved IDDN FR 001 270044 000 D P 2003 000 31500 Somfy SAS capital 20 000 000 Euros RCS Bonneville 303 970 230 Changes can be done by Somfy SAS without notice Page 50 3 Postion 0 100 Function explanation When major alarm input on the Building Controller is active the end products are locked in either the 0 or the 100 position The major alarm is often used to connect the buildings fire alarm system Parameters 1 Enable Disable function 2 Set position in the case of a major alarm Note For the priority degree of this function see 6 6 1 2 Y Do not disable the major alarm function it may jeopardize the safety in the case of an alarm Copyright 2003 SOMFY SAS All rights reserved IDDN FR 001 270044 000 D P 2003 000 31500 Somfy SAS capital 20 000 000 Euros RCS Bonnev
70. n When it snows the end products have to be locked in their secure position This function is not available for interior sun protection Note Rain and Snow functions use the same On and Off delay parameter They also use the same sensor and the system understands that if the temperature is below 4 C the rain becomes snow Parameters 4 Enable Disable function 5 Set On delay The time it must snow before the function turns active 6 Set Off delay From the time it stops snowing before the function turns inactive Note To know the priority degree of this function see 6 6 1 2 Do not disable the snow function it may cause damage to the end products Copyright 2003 SOMFY SAS All rights reserved IDDN FR 001 270044 000 D P 2003 000 31500 Somfy SAS capital 20 000 000 Euros RCS Bonneville 303 970 230 Changes can be done by Somfy SAS without notice Page 47 C 6 6 3 4 8 Frost Function explanation When it is frosty the end products have to be locked in their current position This function is not available for interior sun protection See picture at 6 6 3 4 6 amp Parameters 7 Enable Disable function 8 Threshold when frost function is active 9 Set On delay The time it must be frosty before the function turns active 10 Set Off delay From the time frost disappears before the function turns inactive Note For the priority degree of this function see 6 6 1 2 r Do not disab
71. n module to each motor controller Presence detector inputs This box contains four inputs for presence detectors The presence detectors are used to automatically change the operational mode in the room The inputs adopt the same configuration as the configuration for local switches A presence detector can be connected to more than one input Local control input These four inputs are copies of the switch inputs you find on the motor controller Window contact input There are four inputs for window contacts one for each motor The window contact is used to stop the system or user being able to control sun protection when a window is opened This avoids damaging the end product if a window is opened The inputs adopt the same configuration than the local switches that have been programmed The window contacts can be connected in parrel to more than one input 2 2 4 1 1 Infrared IR remote control module and receiver The module is plugged into the extension box or motor controller to add local remote control functionality You must also connect IR receivers to the module An IR receiver can be connected to more than one extension box to build bigger local groups The remotes will adopt the configuration for which the local switches have been programmed The IR receiver must as all IR products be installed so that the beam from the remote can hit the receiver Data Extension box Number of presence detectors inputs Number of sw
72. nctions but they are not displayed because no feedback is possible N nu Fw For details on the priority order for each operational mode please refer to 6 6 3 5 Copyright 2003 SOMFY SAS All rights reserved IDDN FR 001 270044 000 D P 2003 000 31500 Somfy SAS capital 20 000 000 Euros RCS Bonneville 303 970 230 Changes can be done by Somfy SAS without notice Page 34 6 6 1 3 Sensors The following give detailed information about the sensor status form Only sensors connected to your system will be shown in the form Wind sensors Wind 1 Extenio Wind 2 E tai Wind 1 E Wind 2 Etaio Wind direction Extetiot sensor box 1 Suntensors Sun 1 Extesior sensor box 1 Sun 2 Extesior sensor box 1 Sun 3 Extesior sensor box 1 Sun 4 Extesior senso box 1 Sun 5 Extesior sensos box 1 Sun 6 Extesior sensor box 1 Sun 7 Extesior sensor box 1 Sun 8 Extesior senso box 1 Sun 1 Ester sense box 2 Sun 2 Extesior sense box 2 Sun 3 Exterior sensor box 2 Sun 4 Eraio senso box 2 Temperature sensors Outside Exterior sensor box 1 Inside 1 rmai sensor box 1 Inside 2 Interior senso box 1 Explanation of the content Defines sensor type Defines physical sensor name Defines alias for the sensors Defines sensor present values Defines sensor functions The LED will display OK when the sensor is working correctly and Error if there is a problem If the PC is off line the LED di
73. nes After you made changes in the settings we suggest that you save the project The saved file is used as a backup 3 Use the building overview 6 5 2 2 during your setting work It helps obtain a quick overview Al zones wil move to 0 at 2700 Explanation of the content 1 Select Zone or Building functions 6 6 3 3 1 Reset Building Function explanation If local switches are installed the end products position may vary This function ensures that at a given time all end products are at 0 This is a way of extending the life expectancy of the end products Usually the reset time will be set in the evening Parameters 2 Enable Disable function 3 Time when function should execute Note For the priority degree of this function see 6 6 1 2 6 6 3 3 2 Reset local control to automatic Function explanation When local switches are used the motor controller unit no longer executes non security function commands The Reset local control function is used to reset the motor controller unit once again to execute non security functions For example the system is in standard mode with local control possibility At noon all motor controller units are reset to reactivate the central non security functions Parameters 4 Enable Disable function 5 Enable Disable time 1 3 6 Time when functions 1 3 should be executed Copyright 2003 SOMFY SAS All rights reserved IDDN FR 001 270044 000 D P 2
74. nformation 8 2 PC computer If for some reason you have to change the PC proceed as follows 1 Install the animeo IB Operating software on the new PC 2 Start up the computer 3 Connect the building controller to the new PC The PC will start automatically to upload the project See 3 and 4 for more information 8 3 Motor controller If you either add or replace a motor controller you must initialize the new motor controller Please study 6 5 4 1 2 for more details Copyright 2003 SOMFY SAS All rights reserved IDDN FR 001 270044 000 D P 2003 000 31500 Somfy SAS capital 20 000 000 Euros RCS Bonneville 303 970 230 Changes can be done by Somfy SAS without notice Page 65 o Parameter list Here follows a detailed list of all parameters and their possible values Parameter Data 3 Switch type Max value 1 gt European Min value 0 gt US 4 Number of used zones Max value 16 Min value 1 5 Use slave Building Controller Max value True Min value False 6 Software version Building Controller 7 Running time 100 gt 0 Max value 3200 gt 1 10 of a sec Min value 10 gt 1 10 of a sec 8 Running time 0 gt 100 Max value 3200 gt 1 10 of a sec Min value 10 gt 1 10 of a sec 9 Tilt time 0 90 Max value 100 gt 1 10 of a sec Min value 0 10 End product type 11 Is DCF used Max value True Min value False 12 Number of internal sensor b
75. ng referring the tabs 2 Indication of the alias of a zone 3 Indication of control mode of a zone If the PC is not online OFFLINE is indicated 4 Indication of position of the end products of a zone If a zone is locked the back colour of the position box turns red 5 Indication of the type of end product of a zone 6 Information banner Security functions These functions are active in both manual and automatic control mode 7 Information banner Non Security functions These functions are only active in automatic control mode except for Switch Building and Zone command that are active in both manual and automatic control mode Non security functions are divided into a sub group energy functions 8 Function status of a zone Function is active when lit Note Grey always means that the function is disabled g When a security function is active local control is not possible Copyright 2003 SOMFY SAS All rights reserved IDDN FR 001 270044 000 D P 2003 000 31500 Somfy SAS capital 20 000 000 Euros RCS Bonneville 303 970 230 Changes can be done by Somfy SAS without notice Page 31 Explanation of the functions C Major alarm An input on the building controller enables the system to communicate with the building alarm When active the end products will take the programmed position 0 or 100 this hqs been decide for each zone Often use to connect the building fire alarm system PC Build
76. nication Since communication is uni directional between the building controller and the motor controllers you will not receive any confirmation when downloading a Switch configuration As a result it is not possible to obtain feedback from a motor controller regarding its switch configuration so please make a note of your configuration When saving a project the parameters linked to switch configuration are not be saved Only existing swtich configuration stored in the motor controller will be overwritten when update and switch configuration are executed Here you make the configuration of local switch groups and presence detectors The presence detectors will adopt the switch configuration It is possible to download a configuration to a single motor controller a specific zone or the entire project To make a configuration continue as follows Motor Contredleri Switch and Presence Detector Configuration Cet 1 1 C 24831 E 1a2a1 t 3st Cit 202 isg e t Configure an individual motor controller A Select the desired configuration 1 B Select Individual access mode 2 C Enter the motor controller Id number 6 you find the Id on the motor controller housing D Select the zonecorresponding to the motor controller 5 E Click Download button 7 8 Make a note of your configuration as it is not saved in the system Copyright 2003 SOMFY SAS All rights reserved IDDN FR 001 270044 000 D P 2003 000 315
77. ogo are registered trademarks of Somfy SAS Microsoft Windows Outlook Express are registered trademarks of Microsoft Corporation e Symantec is a registered trademark of Symantec Corporation Intel Pentium are registered trademarks of Intel Corporation Adobe Acrobat Reader Acrobat Reader are registred trademarks of Adobe Systems Incorporated EIB is a registered trademark of European Installation Bus Association Lonworks is a registered trademark of Echelon Corporation AII other brands and product names mentioned in this manual are trademarks of their respective owners Use of these trademarks without the prior written consent of Somfy or third parties concerned is not permitted 11 3 animeo software licence agreement For reference purpose is reproduced hereafter the terms and conditions of the animeo Software license agreement you accepted when you have downloaded and installed the animeo Software The following license agreement is between You and Somfy and governs your use of the enclosed animeo Software and its Documentation You and Somfy hereby agree as follows Version 1 0 9 July 2003 Copyright 2003 SOMFY SAS All rights reserved IDDN FR 001 270044 000 D P 2003 000 31500 Somfy SAS capital 20 000 000 Euros RCS Bonneville 303 970 230 Changes can be done by Somfy SAS without notice Page 74 C 11 3 1 Definitions Somfy means the French Company Somfy S A whose head office is
78. om Performance presence detector without local control 6 6 3 5 1 Sensor allocation Select the sensors you want the zone to read from This is not possible when the end product is a window If more than one sensor is allocated the highest value will be used See picture at 6 6 3 4 for an overview Copyright 2003 SOMFY SAS All rights reserved IDDN FR 001 270044 000 D P 2003 000 31500 Somfy SAS capital 20 000 000 Euros RCS Bonneville 303 970 230 Changes can be done by Somfy SAS without notice Page 55 6 6 3 5 2 Solar Heating This function is only accessible for solar protection Energy savings and comfort modes E Fees neal coa Extenor Venadan bind SEE SSS Ut Hvar base daniel e threshold then move to the green position Function explanation When the indoor temperature is lower than the threshold 4 and the sun intensity is higher than the sun threshold 5 the sun protection takes position 6 This function is used to gain heat from the sun to lower heating costs Normally this function is used outside working hours Parameters 1 Enable Disable function On delay delay before action is executed Off delay gt delay before function becomes inactive Temperature threshold Sun threshold Position when active normally 0 Note For the priority degree of this function see 6 6 1 2 AVF N 6 6 3 5 3 Solar Heating HVAC controlled This function is only accessible for solar p
79. only at zone level When a local command is given this will not be indicated Visualization of slat angle Only viewable for venetian blinds 8 Zone selector click to select the zone you want to control 10 11 12 13 14 LA Selection of type of control mode Manual or Automatic In manual mode you are able to give manual commands from the PC and no non security functions can be activated In automatic mode all functions can be activated and manual control from the PC is not possible Local control by switches or remotes is pos sible in both modes as long as no security functions are active Click to give command to 0 up in close Click to give a stop command from the PC Click to give command to 100 down out open Click to recall the intermediate position 1 Click to recall the intermediate position 2 Example of how to give a command W Click 1 to select the set of zones you want to control Y Click 7 to select the zone when the zone is selected the panel colour turns green Y Click 9 and select manual mode Y Click 10 14 depending what you want to do Note For the priority degree of this function see 6 6 1 2 Copyright 2003 SOMFY SAS All rights reserved IDDN FR 001 270044 000 D P 2003 000 31500 Somfy SAS capital 20 000 000 Euros RCS Bonneville 303 970 230 Changes can be done by Somfy SAS without notice Page 36 6 6 2 2 Locking command Here you can individually lock any zone or even
80. or example covered by clouds the blind will open after 10 of the off delay time 5 If the sun comes back during the off delay time will return to the previous angle before the sun disappeared Otherwise the blind will be sent to 0 position This function means that the room will not be darkened when the sun disappears for a short while 8 Position and Tilt gt This function varies depending on end product The position taken by the end products when the sun function is active is controlled by this function You can either use a fixed position and angle if the end product is a venetian blind or let the system calculate sun tracking position and angle if the end product is a venetian blind due to the sun angle Sun tracking is recommended for maximum comfort For more information see 6 6 3 4 4 9 Zone Synergy please see 6 6 3 4 5 On threshold 2 cannot be set lower then off threshold 4 and vice versa Copyright 2003 SOMFY SAS All rights reserved IDDN FR 001 270044 000 D P 2003 000 31500 Somfy SAS capital 20 000 000 Euros RCS Bonneville 303 970 230 Changes can be done by Somfy SAS without notice Page 43 Sun angles hour for all months and data Function explanation This function is not available for windows folding arm awnings and markisolettes As explained in 6 6 3 4 3 this function is used automatically to position the end products depending on the sun angle To open the window select sun track
81. ove all time regions by clicking the Clear 14 button Basiiding Timer 3 3 st 10 Gy an 400 sy 60 7 i abo ue na iaa EAE the la 1300 20 00 21 00 2200 2300 000 0001050 1245 to 1830 800101515 Drag mouse on timeline to vet active time regione End products wall bs locked during active time regions Note To change the time format see 6 5 3 3 Note For the priority degree of this function see 6 6 1 2 Copyright 2003 SOMFY SAS All rights reserved IDDN FR 001 270044 000 D P 2003 000 31500 Somfy SAS capital 20 000 000 Euros RCS Bonneville 303 970 230 Changes can be done by Somfy SAS without notice Page 40 6 6 3 4 Zone functions In this window you make individual settings per zone Select zone functions by clicking the zone tab 10 Select zone to edit by clicking list box 11 Chosen zones data is visible below 12 Select function to edit by clicking function tabs 13 If a function is not used its function tab will be disabled grey and not accessible Wind sensor allocation Outside box 1 X 1 Weather station rool as a SI Energy saving no local control Protected angle 6 6 3 4 1 Wind speed Function explanation The wind function is used to ensure that the end products will not be damaged by wind When any of the allocated wind sensors mesure a wind speed which exceeds the wind speed threshold 3 end products will be locked in a secured position This funct
82. oxes Max value 2 Min value 0 13 Is outside sensor box 2 used Max value True Min value False 14 Number of wind sensor outside sensor box 1 Max value 2 Min value 0 15 Number of wind sensor outside sensor box 2 Max value 2 Min value 0 16 Is wind direction sensor used Max value True Min value False 17 Number of sun sensors outside sensor box 1 Max value 8 Min value 0 18 Number of sun sensors outside sensor box 2 Max value 4 Min value 0 19 Number of temperature sensors inside sensor Max value 2 box 1 Min value 0 20 Number of temperature sensors inside sensor Max value 2 box 2 Min value 0 21 Type of wind sensor outside sensor box 1 0 Heated wind speed sensor 1 Wind speed sensor 2 Wind speed sensor station 3 Compact wind sensor 22 Type of wind sensor outside sensor box 2 O Heated wind speed sensor 1 Wind speed sensor 2 Wind speed sensor station 3 Compact wind sensor 23 Type of wind direction sensor 0 Wind direction sensor station 1 Compact wind direction sensor 24 Type of sun sensor Sun sensor station 25 Energy mode internal temperature sensor allocation inside sensor box 1 26 Energy mode internal temperature sensor allocation inside sensor box 2 27 Is outside temperature sensor used Max value True Min value False 28 Is rain sensor used Max value True Min value False 29 Wind sensor allocation outside sensor box 1 Copyright 2003
83. priorities are explained below Note See 6 6 1 2 to review the functions priority order The choice of the operational mode has an impact on all the system Take time to fully understand the implications of each mode to ensure selection of the most suitable mode for a building Copyright 2003 SOMFY SAS All rights reserved IDDN FR 001 270044 000 D P 2003 000 31500 Somfy SAS capital 20 000 000 Euros RCS Bonneville 303 970 230 Changes can be done by Somfy SAS without notice Page 53 UY Standard with local control The system works as a standard solar protection system i e to avoid glare and overheated rooms All energy saving functions are disabled The user can locally control the end product UY Standard without local control Same as above but local switches control are disabled V Energy saving without local control In addition to the standard solar protection functionality energy functions are enabled The enrgy saving functions use the solar protetion to gain or maintain heat and windows for ventilation The user can not control the end products locally to be able to ensure minimized energy cunsumption V Performance timer with local control This mode is a mix between the standard mode and the energy saving mode A time span is set in which the system does not activate the energy saving functions This time span is called user comfort During the user comfort time the user can control locally the end products
84. rotection Function explanation When the HVAC heat input is active and the sun intensity is higher than sun threshold 10 the sun protection takes position 11 This function is used to gain heat from the sun to lower heating costs Normally this function is used outside working hours Parameters 7 Enable Disable function 8 On delay gt delay before the action is executed 9 Off delay delay before the function becomes inactive 10 Sun threshold 11 Position when active normally 0 Note For the priority degree of this function see 6 6 1 2 Copyright 2003 SOMFY SAS All rights reserved IDDN FR 001 270044 000 D P 2003 000 31500 Somfy SAS capital 20 000 000 Euros RCS Bonneville 303 970 230 Changes can be done by Somfy SAS without notice Page 56 6 6 3 5 4 Maintain Heat This function is only accessible for sun protection Function explanation When the indoor temperature is lower than the threshold 4 and the sun intensity is lower than the sun threshold 5 the solar protection takes position 6 This function is used to keep heat in the building by using the sun protection as extra window insulation This will also lower heating costs Normally this function is used outside working hours Parameters 1 Enable Disable function 2 On delay gt delay before the action is executed 3 Off delay gt delay before the function becomes inactiveTemperature threshold 4 Sun threshol
85. s of sensor and number of zones may differ depending on your system This manual describes all the possibilities of animeo Functions vary depending on the type of end product in a zone For example wind functions are YQ disabled for interior Venetian blinds Copyright 2003 SOMFY SAS All rights reserved IDDN FR 001 270044 000 D P 2003 000 31500 Somfy SAS capital 20 000 000 Euros RCS Bonneville 303 970 230 Changes can be done by Somfy SAS without notice Page 30 Owners manual animeo IB operating software a 6 6 1 Status In Status the system visualizes functions and sensor data This is the navigator title you will be using most of the time At a glance you can check your installation 6 6 1 1 Functions In this form you get a quick and total overview of the status of all functions for all zones The functions are listed in priority order top to bottom This means that if more than one function in a zone is active only the function with the highest priority will be executed When a function goes inactive the next active function in priority order will be executed Control mode Rialto Postion ae iti i Exterior Venetian blind j Exterior Venetian blind Information Security functioer Bi za o Disabled Non securty functors Disabled LU Not used in marisa mode Explanation of the content 1 If a system contains more than 4 zones you select the set of zones by clicki
86. se all end products in a zone take their secure position Rain When active all the end products in a zone take their secure position Building timer When active all the end products in a zone take the defined position 0 or 100 This function becomes active if you give an order for more than 1 2 s on the central switch input on the building controller In this case all the end products move to 100 often used for slats cleaning Non security functions PC zone command Active when a manual command is given from the PC Zone timer When active the zone will take the programmed position The position can be intermediate position 10r 2 0 or 100 Reset building 0 When active all zones take 0 position Often used to extend the life of the end products Switch building command Active when the central block input 0 or 100 on the building controller is active less than 1 2 s a manual command is executed Switch zone command Active when the group lock 0 inputs 0 or 100 on the internal sensor box are active less than 1 2 s a manual command is executed Solar heating When active the zone acts to gain heat by for exemple move sun protection to 0 position Copyright 2003 SOMFY SAS All rights reserved IDDN FR 001 270044 000 D P 2003 000 31500 Somfy SAS capital 20 000 000 Euros RCS Bonneville 303 970 230 Changes can be done by Somfy SAS without notice Page 32
87. semi automatic mode will be reset to fully automatic by the reset local control to the automatic PC function If there are presence detectors installed a time out will also reset to fully automatic The functionality leads to avoiding the irritating fact that the end products might move after a local command is given for example sun function turns active or inactive When energy modes are used the local switches might be disabled to ensure for example maximum energy saving Security Security functions always have higher priority than the local switches This results in no risk in controlling local end products when there is a risk of damage to e g wind a To be able to use the local intermediate position function the switch must either have a stop button or have the possibility to press both up and down buttons at the same time b The animeo IB System software cannot monitor a single motor position in a system only at a zone level Data Motor controller F Number of motors that can be connected Number of switches that can be connected 4 Copyright 2003 SOMFY SAS All rights reserved IDDN FR 001 270044 000 D P 2003 000 31500 Somfy SAS capital 20 000 000 Euros RCS Bonneville 303 970 230 Changes can be done by Somfy SAS without notice Page 9 2 2 4 1 Motor controller extension box This box contains inputs and features that expand the motor controller s functionality You can add one extensio
88. splay by clicking on Start Settings Control Panel Display b Select the Appearance tab c1 For Windows 2000 Select Scheme Windows standard c2 For Windows XP Select Style Windows classic style d Click on Apply Screen resolution The software is optimized for a 1024 768 resolution and at least a 16bit colour depth The software will work in any resolution but the most user friendly is in the suggested resolution Proceed as follows a Open the Display by clicking on Start Settings Control Panel Display b Select the Settings tab c Select the colour True Colour 32 bits or 16 bits 32 bits recommended d Select the screen area 1024 768 minimum e Click on Apply Auto hide the Start bar The software has been designed to use the maximum screen area for maximal user friendliness For this reason we advise you to set the Start bar to auto hide The software will work without auto hide enabled but the some functions might be croped Proceed as follows a Right click on the the Start bar and select Properties b Enable Auto hide c Click on Apply Adobe Acrobat Reader To be able to use the help files in the software you must have Adobe Acrobat Reader installed The software will work without Acrobat Reader installed but you will not be able to open the help files You need at least Acrobat Reader version 4 0 Proceed as follows a Go to www adobe com and download the desired Acrobat Reader language
89. splays OFFLINE Indication of possible error if the sensor is not working correctly FWN a Note The precipitation sensor e g rain and snow has an open contact output It is not possible to detect an error on this sensor Copyright 2003 SOMFY SAS All rights reserved IDDN FR 001 270044 000 D P 2003 000 31500 Somfy SAS capital 20 000 000 Euros RCS Bonneville 303 970 230 Changes can be done by Somfy SAS without notice Page 35 rr ni ib Owners manual animeo IB operating software 6 6 2 Control In Control you can give manual commands lock zones or lock the entire building 6 6 2 1 Manual command In this form you can give manual and intermediate commands for all zone fe Au FWN Mode TES Mode RE Position 100 Position 47 Angle 40 Angle 90 Manual command Automatic Manual 100 Intermediate positions Go to position 2 Explanation of the content If a system contains more than 4 zones you select the set of zones by pressing the tabs Zone number Alias of the zone Visualizing the type of end products in the zone and their approximate position Visualizing the control mode Manual or Automatic If the PC is not online OFFLINE is displayed The position of the end products in the zone If the zone is blocked the back colour of the field turns red The software cannot monitor a single motor in the system
90. t Court of Paris France This license agreement supersedes all proposals or other prior agreements oral or written and all other communications between the parties relating to the subject matter hereunder No modification of this license agreement will be binding the parties unless in writing and signed by an authorized representative of each party ACCEPT THE LICENCE AGREEMENT Il DECLINE TO ACCEPT THE LICENCE AGREEMENT Version 1 0 9 July 2003 Copyright 2003 SOMFY SAS All rights reserved IDDN FR 001 270044 000 D P 2003 000 31500 Somfy SAS capital 20 000 000 Euros RCS Bonneville 303 970 230 Changes can be done by Somfy SAS without notice Page 77 12 Contacts For all contacts see www Somfy com or phone Somfy International 00 33 0 4 50 96 70 00 Copyright 2003 SOMFY SAS All rights reserved IDDN FR 001 270044 000 D P 2003 000 31500 Somfy SAS capital 20 000 000 Euros RCS Bonneville 303 970 230 Changes can be done by Somfy SAS without notice Page 78
91. ti n selection Motor controller Help A Building Switch and Presence detector Visit Save project z Language a A overview configuration homepage Load f Hardware Time format Add update or replace motor About configuration overview controller Print project Units Forced communication Exit Temperatur Upload all from building Wind Download all to building Length 6 5 1 File File contains functions regarding file handling printing and termination as in all windows applications The following contains detailed information concerning the menu function File 6 5 1 1 Open project Here you open a project p 6 5 1 2 Save project Here you can save a project It is useful when you want to backup a project p When saving a project all settings and parameters will be saved except switch configuration 6 5 1 3 Load Configuration When any change in the system software should be executed e g extend number of zones you must load a configuration file c followed by for example 20 that indicates the version of the software version 2 0 For example in the future version 3 1 will be called 31 Somfy will supply you with this system software when ordered If the type of an end product is changed in an existing zone please study 7 2 6 5 1 4 Print project info All configurations and settings in your project will be printed This is useful for documenting a project 6 5 1 5 Exit Exit the software When you exit and you
92. to control configure and monitor the system The result is a to a real user friendly interface Note The system will work even if you turn OFF the PC amp Operational modes The sun protection works both in retaining and gaining heat Windows can be controlled by using signals from the HVAC system for ventilation This means that when a room is empty the solar protection and windows functions ensure maximum energy savings When it is cold inside windows are closed and solar protections are opened to gain heat from the sun and vice versa When it is hot inside the windows are used to ventilate the building When the room is occupied the system ensures maximum user comfort in terms of light glare temperature and air quality Sun tracking When configuring a system for the first time you enter latitude and type of sun protection e g venetian blind and awning for each group This data is then used to position the sun protection to its optimal position for the day and for the year Sun protection corresponds to the angle of the sun Remote Access and Email functions By using a PC the system can be remotely controlled from any another computer anywhere in the world over the Internet When service is required e g for sun protection or if an error occurs an email can be generated automatically 2 2 Product overview animeo consists of only a small number of devices Each product is available for either DIN rail or wall mounting
93. ure perhaps yourself maybe in cooperation with Somfy or the architect The best resolution for the picture is 800 600 pixel The picture format must be a standard JPEG picture Select your picture by clicking the button select picture and then select the picture you want to use The picture you choose is stored in the PC so next time you start the software your picture will be selected automatically 6 5 2 3 Hardware overview Here you get an overview picture of the installed hardware In fact this is more or less the same information as in pre configuration graphically The hardware part you are setting is yellow Copyright 2003 SOMFY SAS All rights reserved IDDN FR 001 270044 000 D P 2003 000 31500 Somfy SAS capital 20 000 000 Euros RCS Bonneville 303 970 230 Changes can be done by Somfy SAS without notice Page 24 6 5 3 Settings In the menu you make settings of units language time format and communication port The following gives detailed information about the menu function Settings 6 5 3 1 COM port selection Here you choose the serial communication port that the PC uses to communicate with the building controller The software automatically detects available ports 6 5 3 2 Language You can choose the language for the complete software Available languages are English German French Swedish Dutch Finnish Norwegian Italian More languages will be added in the future This possibility allows you to choose the
94. version b Follow the Adobe installation instructions Configure the computer a Open the Control panel and open Power Options b Select the following options may vary from computer to computer Power Scheme Home Office computer or server Switch off the monitor Optional Switch off the hard disc Never System standby Never Copyright 2003 SOMFY SAS All rights reserved IDDN FR 001 270044 000 D P 2003 000 31500 Somfy SAS capital 20 000 000 Euros RCS Bonneville 303 970 230 Changes can be done by Somfy SAS without notice Page 16 4 2 Configure animeo Operating PC Software The following information explains how to configure the animeo Operating system PC software after installation 4 2 1 animeo system automatic start up sequence As soon as you connect a PC with the animeo IB Operating software running to an animeo system the building controller will start to upload its stored settings and configuration automatically to the PC This means in practice that you can connect any PC computer with animeo IB Operating software installed and you will automatically be online 4 2 2 Configure step by step The following explains in detail how to configure the animeo IB Operating software from the very beginning to a fully running system Configure the RS485 RS232 converter picture below and connect the included 9V DC adapter supplied Please study the animeo installation guide for a more detailed information
95. w through the window Y Screen and Roller shutters For screens and roller shutters you can set a maximum allowed position 11 When making a calculation no position will be greater than the allowed position This is useful for example to always allow a certain view through the window You can also define how far you want the sunlight to enter the room Just enter the height of the screen rolling shutter 12 and the distance 13 you accept the sunlight to enter the room When using this last functionality normally position 11 is set to 100 Used to light up the room with natural sunlight Remember that you can change the unit formats in 6 5 3 4 3 Using the function Set if required parameters 11 13 e Click the calculate button 10 When required make fine tuning 4 8 If you have made some fine tuning and want to recall the calculated values just click Calculate button 10 By clicking Default button 9 you will set all values in 4 8 to o Parameters Sun angle diagram Sun angle magnifier Month indication Angle Position 1 calculation Angle Position 2 calculation Time 1 calculation the time when the angle position 2 5 will be activated Angle Position 3 calculation Time 2 calculation the time when the angle position 3 8 will be activated Default button sets all Angles Positions and Times 4 8 to o Calculate button when clicking 4 8 will be calculated Maximum al
96. ways be installed on the roof of the building where it can read wind from any direction Parameters 6 Enable Disable function 7 Wind threshold the wind speed needed to activate the wind direction function 8 Protected angle direction set the direction of the protected angle by dragging the knob 8 left or right so the direction of the selected facade is in the middle of the lit up diode ring 9 Protected angles size adjust the size of the protected angle by dragging the slider 9 left or right Nor mally a protected angle is 180 and the direction of the facade is in the middle of the scope The wind direction function uses the ON delay 4 and OFF delay 5 from the wind speed function Cc You can change wind units between m s km h and mph please study 6 5 3 4 2 Y Do not disable the wind or wind direction function they may cause damage to the end products Copyright 2003 SOMFY SAS All rights reserved IDDN FR 001 270044 000 D P 2003 000 31500 Somfy SAS capital 20 000 000 Euros RCS Bonneville 303 970 230 Changes can be done by Somfy SAS without notice Page 42 6 6 3 4 3 Sun amp Marketing department Di Sun sensor allocation Outdoor bax 1 O 1 North East ae RI SEn x 3 SouthEast g X 4 South Timer local contol 5 South West C amp West C 7 Noth West J amp Neth Zone synergy 100 34 I Enabled mr 9 Function explanation This function is not availa
97. with the internal zone 2 normally this should be the exterior zone in the same facade The software allows you to link only with external sun protection zones connected on the same building controller unit WY Set Position and Tilt 4 for the zone see 6 6 3 4 3 and 6 6 3 4 4 for more information Parameters 1 Enable Disable function 2 Select zone to link with 3 Data of linked zone 4 Position and Tilt see 6 6 3 4 12 for more information Note For the priority degree of this function see 6 6 1 2 Copyright 2003 SOMFY SAS All rights reserved IDDN FR 001 270044 000 D P 2003 000 31500 Somfy SAS capital 20 000 000 Euros RCS Bonneville 303 970 230 Changes can be done by Somfy SAS without notice Page 46 When active function will secure the end product to postion 0 Function explanation When it rains the end products have to be locked in their secure position This function is not available for interior sun protection Note Rain and Snow functions use the same On and Off delay parameter Parameters 1 Enable Disable function 2 Set On delay The time it must been raining before the function turns active 3 Set Off delay From the time it stops raining before the function turns inactive Note For the priority degree of this function see 6 6 1 2 n Do not disable the rain function it may cause damage to the end products 6 6 3 4 7 Snow amp Function explanatio
98. x value 1439 min gt 23 59 Min value Omin gt 00 00 83 Presence detector timeout Max value 255 gt 20 5min Min value 1 84 Type of presence detector output Max value True gt Closed Min value False gt Open 85 Energy mode sun sensor allocation outside sensor box 1 86 Energy mode sun sensor allocation outside sensor box 2 87 Is solar heating enabled Max value True Min value False 88 Solar heating temperature threshold Max value 25 Celsius Min value 15 Celsius 89 Solar heating active position Max value 100 Copyright 2003 SOMFY SAS All rights reserved IDDN FR 001 270044 000 D P 2003 000 31500 Somfy SAS capital 20 000 000 Euros RCS Bonneville 303 970 230 Changes can be done by Somfy SAS without notice Page 68 90 Solar heating sun threshold Max value 50klux Min value 1klux 91 Solar heating on delay Max value 10min Min value 1min 92 Solar heating off delay Max value 30min Min value 1min 93 Is solar heating HVAC enabled Max value True Min value False 94 Solar heating HVAC active position Max value 100 Min value 0 95 Solar heating HVAC sun threshold Max value 50klux Min value 1klux 96 Solar heating HVAC on delay Max value 10min Min value 1min 97 Solar heating HVAC off delay Max value 30min Min value 1min 98 Is maintain heat enabled Max value True Min value False 99 Maintain heat temperature threshold Max value 25 Celsius Min value 15 Celsius 100 Maint
99. zone The key zone inputs are quite smart if you give a short pulse less then 1 25 the system interprets the command as a command to order the sun protection up or down If a pulse is longer than 1 2s in an up direction the system interprets the command as a locking command This is very useful when you want to lock a zone for example window cleaning Data Inside sensor box 1 Number of Internal temperature sensors that can be connected 0 2 Number of Key zone inputs used for zone 1 8 that can be connected 1 8 Data Inside sensor box 2 Number of Internal temperature sensors that can be connected 0 2 Number of Key zone inputs used for zone 9 16 that can be connected 1 8 This may vary depending on configuration Copyright 2003 SOMFY SAS All rights reserved IDDN FR 001 270044 000 D P 2003 000 31500 Somfy SAS capital 20 000 000 Euros RCS Bonneville 303 970 230 Changes can be done by Somfy SAS without notice Page 8 2 2 4 Motor controller This is the unit on which you connect the motors and switches There are different models for AC and for DC motors You can install up to 100 motor controllers per zone for AC Only one motor must be connected per output parallel connection of motors is not allowed Up to four motors can be connected per motor controller Local groups Each motor controller allows you to connect up to 4 switches for local manual control The switc
Download Pdf Manuals