Home
SiteUSB Device Server - Microedge Instruments
Contents
1. 407 15216 North Bluff Road White Rock BC Canada V4B 0A7 Toll Free 1 877 352 9158 Web Site www microedgeinstruments com Email info microedgeinstruments com Rev 1 1 June 2012 Microedge Instruments Inc Toll Free 1 877 352 9158 407 15216 North Bluff Road info microedgeinstruments com White Rock BC Canada V4B 0AT www microedgeinstruments com Conditions of Sale and Product Warranty Microedge Instruments Inc MEI and the Buyer agree to the following terms and conditions of Sale and Purchase 1 Limited Warranty MEI warrants its product s to be free from defects in materials and workmanship for a period of one year from the date of registered purchase Any unit which is found to be defective will at the discretion of MEI be repaired or replaced MEI will not be responsible for the repair or replacement of any unit damaged by user modification negligence abuse improper installation or mishandling MEI reserves the right to alter any feature or specification at any time 2 Limitation of Liability The product must NOT be used in applications where failure of the product could lead to physical harm or loss of human life Buyer is responsible to conduct their own tests to meet the safety regulation of their respective industry IN NO EVENT WILL MEI BE LIABLE TO ANY PARTY FOR ANY DIRECT INDIRECT INCIDENTAL SPECIAL CONSEQUENTIAL OR PUNITIVE DAMAGES FOR USE OF THE PRODUCT INCLUDING WITHOUT LIMITATION LOST PROFI
2. 04 Readings E0 Days 14 Hours 56 Minutes User Selected Memory 2095104 Readings BO Days 14 Hours 56 Minutes Used Memory fO560 Readings OF 06 2017 5 18 53 PM 2 Days 1 Hours 3 44 The logger ts currently logging data Channels Channel O Thermistor CHO 1 External Thermistor 2 External Thermistor 3 External Thermistor 4 External Thermistor 5 External Thermistor 6 External Thermistor f External Thermistor Enabled Description Equation Cal Low Cali High Temperature 0 Resistance Resistance Resistance Resistance Resistance Resistance If you have more than one data logger connected to the Device Server you will see more logger icons under the Connection You can double click any of them to show their status in the status panel Note You can only view one status of the logger under the same connection at a time If you want to view real time view of multiple data loggers you need to create multiple connections 4 Device Server Settings You can change the password and the port number of the Device Server from Site View Microedge Instruments Inc 407 15216 North Bluff Road White Rock BC Canada V4B 0AT 11 Toll Free 1 877 352 9158 info microedgeinstruments com www microedgeinstruments com When the Device Server is released from the factory the default password 1s 12345 We recommend you change the password immediately for security purpose If you have m
3. 407 15216 North Bluff Road Toll Free 1 877 352 9158 Microedge White Rock BC Fax 1 877 453 0658 Instruments Inc Canada V4B 0A7 Email info microedgeinstruments com Phone 604 424 9092 Web www microedgeinstruments com eUSB Device Server kE User s Manual Microedge Instruments Inc 407 15216 North Bluff Road White Rock BC Canada V4B 0A7 Toll Free 1 877 352 9158 www microedgeinstruments com About this Manual This manual contains operational information for Site Log Data Loggers Please read this manual before using the data loggers Limits of Liability and Disclaimer of Warranty The manual contained in this document is furnished for informational use only and is subject to change without notice Microedge Instruments Inc shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing performance or use of this material Copyright and Trademarks This manual contains proprietary information which is protected by copyright All rights are reserved No part of this document may be photocopied reproduced or translated to another language without prior written consent of Microedge Instruments Inc Microedge Instruments Inc Site Log Site USB Device Server SiteView are the trademarks of Microedge Instruments Inc All other trademarks and registered trademarks are the property of their respective owners Microedge Instruments Inc
4. 8 407 15216 North Bluff Road info microedgeinstruments com White Rock BC Canada V4B 0AT www microedgeinstruments com
5. BC Canada V4B 0AT www microedgeinstruments com The default password for the Device Server is 12345 Click OK to save the Connection and close the dialog Access Data Logger Select the new created Connection icon lt a ew Delete Click Contact button or double click the icon to start the communications On success the data logger icon Model S N will appear under the Connection S S a Contact New Delete Close USE Device Server 4B LFTHA S N 010601000700 E LAHT 1 574 020401000700 E LPVE 1 5 8 010701000078 E LPCE 1 S N 0108010003EF E LFC 1 S N 010201000513 3 LAHT 1 S N 0204010003E5 E LAHT 1 S N 020401000400 E LPT S N 0101010003F2 E LPTM 1 52K 010301000440 li 108 el laptop Double click the data logger icon to load the status of the data logger Microedge Instruments Inc Toll Free 1 877 352 9158 407 15216 North Bluff Road info microedgeinstruments com White Rock BC Canada V4B OA7 www microedgeinstruments com EY LPTH 1 5 N 010601000700 i Real Time i g Refresh i Download S configure Clear NA Calibrate al General Alarm and Excitation LED light when sampling Description Mew Logger Sampling Interval 20 Seconds Start Time 07062011 8 19 03 PM End Time 0062011 9 18 43 PM The logger was last configured at Logging Method Overwrite oldest data when memory tull Total Memory 20951
6. DATA LOGGERS aa tasers rts rin tiero nea EEEE EENE E 6 CORNE TITON IVOR ero A E O E A A 6 ag 1 14 3 UP E A E E EAA AE E A AAA 7 A PC Ce sete DTE SES aia staca tances R E E A 8 CORRE AE CORN C TON apse cee vanes cetacean E EE 3 ACCE S DATA LOGOR errr a nee rn E A nee ere 10 Bh MCN WCC SST CM CUS E E E EE E S 11 S a a A AO i eee E E E E E ee 14 CONNECT MORE THAN 10 LOGGERS cccccccccceecccseccceeccceuecceecceuecceeucsceucceeueceuecsueuceseueseueseusess 14 ET DU BOADE cian nese me enn E O nner eee een Seen ee reer 15 Pe MANN ON aoe tceiPeret seers E E E E 16 3 Microedge Instruments Inc Toll Free 1 877 352 9158 407 15216 North Bluff Road info microedgeinstruments com White Rock BC Canada V4B OA7 www microedgeinstruments com 1 What s In the Box m 1 Site USB Device Server m 1 Power cable m 1 Network cable 2 introduction Site USB Device Server is an USB over Ethernet device server which enables work with the remote Site Log data loggers over a local network or Internet as if they were connected directly to the local PC Microedge Instruments Inc Toll Free 1 877 352 9158 407 15216 North Bluff Road info microedgeinstruments com White Rock BC Canada V4B 0AT www microedgeinstruments com 0 20 18 C 1 55 2 LAN or the Internet W az gt USB a 0 20 18 C 1 55 2 Site USB Device Server Site Log Data Logger Computer With SiteView Site USB Device
7. Server uses off the shelf product PogoPlug hardware as the platform with the only dedicated software enabled to handle the communications between the Ethernet and the Site Log data loggers All original functions of PogoPlug are disabled WARNING PLEASE DO NOT TRY TO ENABLE OTHER SERVICE THAT MICROEDGE DOES NOT SUPPORT Microedge Instruments Inc Toll Free 1 877 352 9158 407 15216 North Bluff Road info microedgeinstruments com White Rock BC Canada V4B 0AT www microedgeinstruments com 3 installation Connect to Data Loggers Site USB Device Server can connect up to 25 Site Log data loggers The first four data loggers can be plugged directly to the available USB ports You can connect USB hub to extend the USB ports Since all data loggers are powered by the Device Server if the connected data loggers will be more than 10 please use 5 VDC self powered USB hub for the rest of the data loggers Connect to Network Use the provided Ethernet cable to connect the Device Server directly to the Ethernet network Microedge Instruments Inc Toll Free 1 877 352 9158 407 15216 North Bluff Road info microedgeinstruments com White Rock BC Canada V4B 0AT www microedgeinstruments com The Device Server will accept the IP address that the DHCP server assigned for it You may find it from your router s DHCP settings or obtain it from the administrator Power Up Connect the device to the power source with the provided
8. TS OR REVENUES COSTS OF REPLACEMENT BUSINESS INTERRUPTIONS LOSS OF DATA OR DAMAGES RESULTING FROM USE OF OR RELIANCE ON THE PRODUCT EVEN IF MEI IS EXPRESSLY ADVISED ABOUT THE POSSIBILITY OF SUCH DAMAGES 3 Extended Warranty Extended 2 year warranty service is available to purchase on new products at time of order entry and up to ninety days thereafter The extended warranty protects you from unbudgeted service expenses and provide additional 2 years of protection at a fraction of the price of a repair 4 Return Policy Defective Product Return A Buyer may return a defective product to MEI for repair or replacement at MEI option in the event MEI determines that the product is defective The defective product must be returned to MEI within the warranty period The Buyer shall be responsible for all shipping costs Repaired or replaced products are warranted for the balance of the original warranty period or at least 90 days Non defective Product Return Products that are not defective may be returned to MEI within 30 days from the date of shipment All non defective product returns are subject to a 20 restocking fee If the product is unsatisfactory for the application for which it was purchased MEI shall at its option either refund the purchase price paid by the Buyer or replace the product with one that is satisfactory for the application The Buyer shall be responsible for all shipping costs and restocking fee determined by MEI Met
9. hod of Return Prior to returning the product completely fill out the RMA Application Form send it to MEI or contact MEI directly for a Return Material Authorization number All products returned to MEI must be securely packaged in the original shipping materials and reach MEI without damage and shipped in accordance with Applicable laws rules and regulations The products must contain all software and accessories that were shipped to the Buyer in connection with the product 5 MEI reserves the right to alter any feature or specification at any time Notes to Buyer If you disagree with any of the above terms or conditions you should promptly return the unit to the manufacturer or distributor within 30 days from date of purchase Microedge Instruments Inc Toll Free 1 877 352 9158 407 15216 North Bluff Road info microedgeinstruments com White Rock BC Canada V4B 0AT www microedgeinstruments com TABLE OF CONTENTS POU CNS N A seca upejestce ass EE ae om seanen aus ensetacsecosmeseqncssmesecsdaaosossesosonesses eenaesesucmusaseecasmsust 0 LIMITS OF LIABILITY AND DISCLAIMER OF WARRANTY ccccccsccsscceceuccesceucesscesceucessseesesseeeseesesees 1 COPYRIGHT AND TRADEMARKS ccccccccsecccseccesecccecsceuceccueceeuecseecsseesseeucseeecseuesseeecsseesseeeeseeneseees 1 Mes VY A Ae BO e E EAE AE 4 e O e E E sie eaeatee seamed eaaps demanelstieeacnteacapadeuscaaettuemees 4 o BITS Cal AO Mas E E TE E E E A A E N T EE 6 CONNECT TO
10. nnection USB Server Step 1 Change Settings Pork 5676 1024 to 65535 Password Confirm Password 4 10 characters or numbers Step 2 Save Settings Save Settings The Device Server will be restarted and when the timer counted down to zero close the dialog EEE 3 Microedge Instruments Inc Toll Free 1 877 352 9158 407 15216 North Bluff Road info microedgeinstruments com White Rock BC Canada V4B OA7 www microedgeinstruments com Remote USB Device Server Configuration You are about to change the remote USB Server settings After you click Save button the USE Server will be reset and you need to wait for 30 seconds before re establishing the connection USB Server Step 1 Change Settings 1024 to 65535 Password Confirm Password 4 10 characters or numbers Step 2 Save Settings Step 3 Wait 13 If you have made the changes successfully the password and the port of the current Connection will be changed automatically Double click on the Connection icon to re establish the communications 5 Extending Network Connect More Than 10 Loggers Because the Device Server provides the power source to all connected data loggers the maximum data loggers that can be powered by the Device Server is limited to 10 If you need to connect more than 10 data loggers you must use self powered USB hub and the power supply of the hub should be 5 VDC 14 Microedge Inst
11. power cord The Device Server accepts 110 240VAC 50 60HZ Microedge Instruments Inc Toll Free 1 877 352 9158 407 15216 North Bluff Road info microedgeinstruments com White Rock BC Canada V4B 0AT www microedgeinstruments com The device needs 100 seconds start delay in order to finish the initialization Do not try to communicate with the device within this period of time 4 Accessing Data Loggers Site View Windows software is used to communicate with the Site Log data logger for data downloading logging management and channel range configuration Create Connection In order to communicate with the Device Server you need to create a Connection Launch SiteView Click USB Device Server tab on the communication panel laptop Microedge Instruments Inc Toll Free 1 877 352 9158 407 15216 North Bluff Road info microedgeinstruments com White Rock BC Canada V4B 0AT www microedgeinstruments com Create Connection Click New button to show a new Connection dialog 192 168 0 120 New remote site IP Address 1927 168 0 1240 Port mg 1024 to 65535 Timeout 5000 100 10000 Enter the description about this connection Change the IP address to the one that you got in the preceding steps You can keep all other settings default Microedge Instruments Inc Toll Free 1 877 352 9158 407 15216 North Bluff Road info microedgeinstruments com White Rock
12. ruments Inc Toll Free 1 877 352 9158 407 15216 North Bluff Road info microedgeinstruments com White Rock BC Canada V4B 0AT www microedgeinstruments com Each data logger consumes about 0 125W when it is powered by the USB port Please check the power capacity of the USB hub when you choose one and decide how many data loggers it can drive VSB 2 0 7 Port HUB Ss AA a x n i od fod fan ue A Self Powered USB Hub Extend USB Cable According to USB standard USB operating specifications limit the maximum length of the cable to 5 meters 5 meters is around 16 feet 5 inches The USB standard allows up to 5 hubs between a USB host device and USB slave device If you use cables of 5 meter each this gives a total cable length between the USB Device Server and the data logger of 30 meter USB Hub USB Hub USB Hub USB Hub USB Hub USB Server 15 Microedge Instruments Inc Toll Free 1 877 352 9158 407 15216 North Bluff Road info microedgeinstruments com White Rock BC Canada V4B 0AT www microedgeinstruments com 6 Specifications Product Name Model Software IP Addressing Power Requirements Approvals Ethernet USB Max Loggers Up to 25 Site Log loggers can be connected to the Server Self powered USB hubs required if more than four loggers Max Clients Up to 20 clients can access Site Log data logger at the same time Max Baud Rate Microedge Instruments Inc Toll Free 1 877 352 915
13. ultiple Device Servers and they are under a router and you want them to be exposed to the Internet you may need to assign different ports to different Device Servers Once you finished the redirection in the router s configuration you can visit all Device Servers from outside To change the settings Double click on the Connection icon to establish the communications with the Device Server Right click on the Connection and select USB Device Server Properties a lA q Contact New Delete Close rial USB Device Server Contact Properties fi LPCB 1 5 N UT USUTOOUSEF i LPC 1 S N 010201000513 i LAHT 1 5 N 0204010003E 9 i LAHT 1 5 N 020401000400 ie LPY 1 S N O01 01 0003F 2 i LPT 1 5 N 010301000440 108 el laptop Type in the existing password The factory default password is 12345 USB Device Server Passw Please input the password OOo o i In the Remote USB Device Server Configuration dialog change the password and the port and click Save Settings 12 Microedge Instruments Inc Toll Free 1 877 352 9158 407 15216 North Bluff Road info microedgeinstruments com White Rock BC Canada V4B OA7 www microedgeinstruments com Remote USB Device Server Configuration You are about to change the remote USB Server settings After you click Save button the USE Server will be reset and you need to wait for 30 seconds before re establishing the co