Home

User manual ET

image

Contents

1. L1 N PE o LH RIS SIS SIG o transformer 2 M046 O I 2 5 5 ASU2 gt 5 I eo Socket for O vg gt 5 timer module ASU2 2 vo l LER OO 5 l ISE T SYNC RELEASE O BT ae Multi o multi functional relay 230Vac max 60W RL socket for radio remote Warn R warning light 230Vac max 60W Se control receiver Ae oO P g Rot o red traffic light 230Vac max 60W E E EN T T Grun io green traffic light 230Vac max 60W LS lest LS SLA SLZ BTBGBABZ BS GL ER Te lS H Q 2 2 Z R Ne N N nnm Ww gt S gt Z h Z F gr 3 3 2 u ee ae ans e 2 s a 436 1k0 kO k Heras productie maatschappij B V Gebr ET Odysseus Delta_130607_UK R amp D Page 15 45 13 6 2007 ee es C 4 2 Internal wiring Odysseus sliding galfon R amp D Heras pro 8 2kOhm Safety contact profilo LLOSED 8 2kDhm safety contact profil
2. e All safety strips intended to prevent entrapment when opening the gate are checked by pressing when opening The gate will stop immediately and reverse direction The LED SLA will light up e All safety strips intended to prevent entrapment when closing the gate are checked by pressing when closing The gate will stop immediately and reverse direction The LED SLZ will light up e The safety strip on the gate is a passive strip Odysseus If the strip comes into contact with an object at a certain level of resistance the gate will immediately come to a standstill and reverse in direction e The gate should be regularly be checked to make sure it can move unimpeded The area of movement and guider lower beam must be free of snow and ice weeds or any other objects that might impede the movement of then gate SLA SLZ If these do not work the gate should be deactivated since safety cannot be guaranteed You should contact the Service Maintenance Dealer Heras productie maatschappij B V Gebr ET Odysseus Delta_130607_UK R amp D Page 12 45 13 6 2007 ee es C User Manual Odysseus Delta with motor type ET 33 2 Emergency release The emergency release can be found on the sides of the motor unit This stops the movement of the gate on the one hand due to the fact that the toothed wheel comes free from the toothrack on the other hand as a result of a switch which stops the motor unit The gate can only be oper
3. 10 1u LS 2u OV 20 24Vdc 30 3u BA 4o 4u BZ 5o 5u BTG 60 6u BTS 70 7u Warning light 24Vdc 80 8u MULTI 230Vac 90 9u N 100 10u L1 Page 16 45 Gebr ET Odysseus 13 6 2007 Me es C 4 3 Internal wiring Delta sliding gate R amp D User Manual Odysseus Delta with motor type ET Inductive contact profile evaluation with ASO System o O Ss a Transformator MO46 Steckplatz fur Wochenschaltuhr Gleichrichter O Lern N l Ole Z Vo LU GI I O OP ulti a teckplatz fur Warn R unkempfanger Rot E i O Gr n A a Darn 5 o RIR e Oe IIS
4. 4 Service Maintenance Dealer In the event of problems defects or questions please contact Dealer name Telephone lt tel dealer gt Fax lt fax dealer gt Copies of this manual can be re ordered via the telephone or fax number listed above Heras productie maatschappij B V Gebr ET Odysseus Delta_130607_UK R amp D Page 7 45 13 6 2007 ei es C User Manual Odysseus Delta with motor type ET 1 5 Conformity with European guidelines Installation is carried out in conformity with the following EU Guidelines 98 37 EC Machinery Directive 73 23 EEC Low voltage Directive 89 336 EEC EMC Directive electromagnetic compatibility The declaration of conformity can be found in appendix C The nameplate is affixed on the front or rear side of the gate Heras productie maatschappij B V Gebr ET Odysseus Delta_130607_UK R amp D Page 8 45 13 6 2007 Weel Fy User Manual Odysseus Delta with motor type ET 2 Installation End stoppers slam support front and rear must be used at the open and closed positions The stopper for the closed position will also prevent the existing safety contact profiles from being actuated The foundations of gate and gate opener must be free from frost The opener must be at least 30mm higher than the surrounding terrain and at least 100mm from the gate opening Make sure sufficient cable or cable conduit is laid before the foundation is cast 2 1 Mounting the rack The plastic rack is
5. by BTG is not possible when opening into the end position OPEN 4 6 6 Automatic closure for complete opening Automatic closure for full opening can be selected in the learning sequence 4 6 7 If LS or SLZ or BA is active during the stay open time the stay open time elapses but the gate remains open If BA is pressed in the end position OPEN then the stay open time restarts If channel 1 on the timer ASU2 is activated the stay open time elapses but the gate remains open The blocked automatic closure is released by a BA command and the stay open time restarts The gate closes automatically when the stay open time has elapsed provided the automatic closure is not blocked and no safety device or BA command prevents the closing The gate closes immediately when BT or BZ is pressed in the position CLOSE When delayed closure is activated and a CLOSE command is stored then the gate closes immediately after reaching the end position OPEN When BT is pressed during automatic closure stop and reversing in direction OPEN occur Automatic closure for partial opening Automatic closure for partial opening can be selected in the learning sequence R amp D When the gate is not in the partial opening position and the BTG button is pressed the gate is moved into the partial opening position When the partial opening position 1s reached the selected stay open time for the partial opening starts to elapse If the gate is in the parti
6. position OPEN Heras productie maatschappij B V Gebr ET Odysseus Delta_130607_UK R amp D Page 23 45 13 6 2007 Me es C User Manual Odysseus Delta with motor type ET 4 6 11 Emergency mode after power switch on and after emergency release When the controller is switched on initially the gate position is not known and only the running direction CLOSE is permitted When a safety device for direction CLOSE failed then pre warning before emergency mode is started and the gate is closed in emergency mode until BT BTG or BZ is released When the end position CLOSED is reached and the gate is stopped by force detection then the controller changes into normal mode Opening in emergency mode before reaching of end position CLOSED is not possible Heras productie maatschappij B V Gebr ET Odysseus Delta_130607_UK R amp D Page 24 45 13 6 2007 ee C User Manual Odysseus Delta with motor type ET 5 Safety functions 5 1 Force detection obstacle detection and end position detection During learning function v a running distance for opening and closing the controller has determined and saved the force required During operation the actual force is compared with the learned force When the actual force is higher than the learned force by more than one selected force reserve then stop by force detection occurs Force detection during Force detection during closing opening Stop and reversing for a short With automatic closure in the OPEN po
7. to the gate and in the centre between the wheel carriages Principle Odysseus e Mark the middle of the elongated holes on the foundation e Take the opener from the foundation and drill holes for 8 10mm fixing screws More details about the anchors can be found in the foundation drawing e Position the anchors and fit these with a nut and washer e Position the motor unit on the anchors For Delta gates the motor unit is fixed to the support provided This support is attached to the portal by means of clamping brackets More details can be found in a separate manual assembly manual for 10 motor unit ET 2 3 Adjusting the motor unit e Position the toothrack holder in such a way that this can be slid upwards downwards e Position the gate leaf in a central position e Adjust the height of the motor unit so that the toothed wheel falls into place in the toothrack Caution The toothed wheel must have some play in the toothrack approx 1mm The motor should be connected e Check that the motor unit runs parallel with the gate leaf and is level e Tighten the nuts on the motor unit e Check that the toothed wheel runs along the centre of the toothracks Slide the gate open and closed and check that the tolerance is approx 1mm in all places If necessary adjust the height of the motor unit toothrack Check again that the toothrack is correctly fitted and that all screws on the toothrack holder and t
8. used to open the gate When the gate is in the end position OPEN BT is used for closing 4 6 3 2 Pedestrian opening by BT and the associated radio link Without automatic closure for partial opening Is the gate not in the selected partial opening position use BTG to move it into the partial opening position When the gate is moving use BTG for stopping Priority sequence Opening up to the end position has priority over stopping through BTG If the gate is in the partial opening position use BTG for closing With automatic closure for partial opening If the gate is not in the selected partial opening position use BTG to move it into the partial opening position If the gate is in the partial opening position use BTG for closing 46 4 Operation by BA BZ and BS BA has the function OPEN BZ has the function CLOSE and BS has the function STOP As long as BS is pressed no gate movement is possible The automatic closure is blocked by BS When BS is released a new operation command must be given As long as BA is pressed the gate cannot close Heras productie maatschappij B V Gebr ET Odysseus Delta_130607_UK R amp D Page 21 45 13 6 2007 4 6 5 ee es A a User Manual Odysseus Delta with motor type ET Priority sequence BA has priority over BT BTG and BZ When BA is pressed and the gate opens it cannot be stopped using BT or BTG or closed using BZ The opening into the end position OPEN has priority over partial opening Stopping
9. 05 NEN 6772 EN 12445 2005 NVN ENV 1991 2 4 EN 12444 2000 NVN ENV 1993 EN 13241 1 2003 And further declares that it 19 forbidden for anyone to put into operation the complete installation gate and motor unit before the machine has been found and to be declared to be in conformity with the requirements of the machine directive 98 37 EC and with national legislation pursuant to this directive Oirschot 2 1 02 2007 Hans Welting Managing Director Heras productie maatschappij B V Gebr ET Odysseus Delta_130607_UK R amp D Page 44 45 13 6 2007 ee C User Manual Odysseus Delta with motor type ET Heras Fencing Systems B V Notes Heras productie maatschappij B V Gebr ET Odysseus Delta_130607_UK Page 45 45 13 6 2007 I amp C ei es C User Manual Odysseus Delta with motor type ET Heras productie maatschappij B V Gebr ET Odysseus Delta_130607_UK R amp D Page 46 45 13 6 2007
10. 13 6 2007 ee es C User Manual Odysseus Delta with motor type ET 1 GENERAL 1 1 Manufacturer supplier Manufactured by Heras Productie Maatschappij B V Hekdam 1 5688 JE Oirschot The Netherlands Supply and assembly Dealer name Street place 1 2 Using this manual This user manual describes how the cantilever sliding gate hereinafter referred to as the gate should be operated and what actions should be taken in the event of breakdown This document also deals with maintenance and safety aspects The contents of this document are intended for the operator of the gate and for the technician responsible for its installation The technician will use a separate manual for installation of the motor unit on the gate This will include an assembly diagram for the motor unit in question and this will operate in conformity with the Dutch NEN 1010 standard For technical defects of whatever nature a qualified dealer name technician must be consulted 1 3 Definitions of User Operator Technician User Anyone using the gate Operator A user who is familiar with all safety aspects dealt with in this document The operator is not permitted to carry out any installation work on the gate unless explicitly specified Technician The technician is the person appointed by the dealer name including a chent s employee specifically appointed for this purpose by Heras who is qualified to carry out technical work on the gate 1
11. BIS E OJOJOJOJOJO O O e 9 Oo Ea EE la El e EE 9 S ololojo a o Q I k PE lt 1 N Rdy gt 97 so Volt ad oo oDC ok oC 0 GC O TE 24V DC 30W 10 204 TOOT N 11 10 1u LS 2u OV 20 24Vdc 30 3u BA 4o 4u BZ 50 5u BTG 60 DU BTS 70 7u Warning Light 24Vdc 80 8u MULTI 230Vac 9o 9u N 100 10u L1 Heras productie maatschappij w v Delta_130607_UK Page 17 45 Gebr ET Odysseus 13 6 2007 ei es C User Manual Odysseus Delta with motor type ET 4 4 Connections of the controller MO46 441 Controller input terminals nput Version Connection Function _ _ _ terminal opening terminal terminal terminal terminal BZ n c contact 2 pin screw plug Push button STOP Redundant terminal detection on the controller according to EN954 1 category 3 Max 6 photo 2 pin screw plug Photo cells cells with n c terminal according to EN954 1 category 2 contact and terminating resistor 1kQ Resistor 2 pin screw plug Integrated detectors with testing detection terminal function according to EN954 1 n c contact with category 2 for safety contact 8 2kQ resistor profile for gate OPEN SLA and serial CLOSE SLZ terminal Pulser 3 pin connecting plug Pulser not protected against misconnecting release emergency release Plug socket Connection for timer ASU2 Integrated radio remote control OOO Plug socket for receiver EKX10F decoder BT BTG Multi or receiv
12. Heras productie maatschappij B V Gebr ET Odysseus Delta_130607_UK R amp D Page 36 45 13 6 2007 ee es C User Manual Odysseus Delta with motor type ET 6 14 Sequence PD Adjusting maintenance interval 66 66 mm When sequence PD is activated by button LERN the maintenance interval is displayed or when no maintenance notice will be given Using BT the monitoring can be switched on and the maintenance interval can be increased Using BTG the maintenance interval can be decreased and the monitoring can be switched off The decimal points on the display are each equal to 100 example Prescaler 1 1000 Maintenance notice when counter displays gt 23 thus after 23 x 1000 23 000 cycles 1000 123 000 cycles Maintenance notice when counter displays gt 2 3 thus after 23 x 1000 223 000 cycles Attention Adjusting the maintenance interval is also possible when the multifunctional relay is set up to not release maintenance notice Ta Maintenance notice when counter displays gt 23 thus after 123 x In order for the controller to generate the maintenance notice the following has to be selected in the learning sequence 1 The mode sliding gate has to be selected 2 The maintenance interval has to be set to the desired value 3 The multi functional relay has to be set up to release maintenance notice 4 The maintenance counter has to be reset to zero if applicable Heras productie maatschappij B V Gebr ET Odysseu
13. S C JA 2 User Manual UK Sliding gate Odysseus Delta Motor Type ET Odysseus ei es C User Manual Odysseus Delta with motor type ET Heras productie maatschappij B V Gebr ET Odysseus Delta_130607_UK R amp D Page 2 45 13 6 2007 ee C User Manual Odysseus Delta with motor type ET 1 GENERAL 7 1 1 Manufacturer supplier 7 1 2 Using this manual 7 1 3 Definitions of User Operator Technician 7 1 4 Service Maintenance Dealer 7 1 5 Conformity with European guidelines 8 2 INSTALLATION 9 2 1 Mounting the rack 9 2 2 Installating the motor unit 10 25 Adjusting the motor unit 10 3 SAFETY WHEN USING AND DURING WORK IN PROGRESS 11 3 1 Safety in general view of opening 11 3 2 Safety during work in progress and when installing 11 3 3 Safety precautions on the gate 12 3 3 1 Personal safety and regular inspection 12 3 3 2 Emergency release 13 3 3 3 Infrared vehicle protection device in the gate opening optional 13 3 3 4 General notes of safety 14 4 INSTALLING AND OPERATING THE GATE 15 4 1 Controller MO 46 15 4 2 Internal wiring Odysseus sliding gate 16 4 3 Internal wiring Delta sliding gate 17 4 4 Connections of the controller MO46 18 4 4 1 Controller input terminals 18 4 4 2 Controller output terminals 19 4 4 3 Buttons on the controller 19 4 4 4 Light display on the controller 20 4 5 Operation 20 Heras productie maatschappij B V Gebr ET Odysseus Delta_130607_UK R amp D Page 3 45 13 6 2007 ee C 4 6 Operation
14. T Odysseus Delta_130607_UK R amp D Page 25 45 13 6 2007 Me es C User Manual Odysseus Delta with motor type ET 5 6 Safety contact profile for gate OPEN SLA and for gate CLOSED SLZ The controller has two integrated detectors with testing function according to EN954 1 category 2 for safety contact profiles with resistor detection for safety at the closing edge in direction OPEN and CLOSE During learning function of the controller it recognises the type of safety contact profile connected The status of the safety contact profiles is displayed by the red LEDs SLA and SLZ During actuation of a safety contact profile the corresponding LED is lit e The safety contact profile SLA protects the running direction OPEN When SLA reports only emergency mode is possible for opening e When SLA reports during opening stop and short reversal occur e The safety contact profile SLZ protects the running direction CLOSE When SLZ reports only emergency mode is possible for closing e When SLZ reports during opening the following applies With automatic closing STOP and opening occur After two attempts to close by automatic closure or without automatic closure or during dead man s mode only stop and reversing for a short distance occur 5 7 Safety contact profiles with 8 2kQ terminating resistor Closing contacts with 8 2kQ 5 parallel resistor or opening contacts with 8 2kQ 5 serial resistor can be connected If safety contact profiles are
15. al characteristics 4 6 1 Electrical installation 4 6 2 _ Perfomance after main switch on and emergency release 4 6 3 Control sequence by BT and or BTG in normal operation with self retain 4 6 4 Operation by BA BZ and BS 4 6 5 Priority sequence 4 6 6 Automatic closure for complete opening 4 6 7 Automatic closure for partial opening 4 6 8 Dead man s mode 4 6 9 Emergency mode 4 6 10 Emergency mode with automatic closure for complete opening by BT 4 6 11 Emergency mode after power switch on and after emergency release 5 SAFETY FUNCTIONS 5 1 Force detection obstacle detection and end position detection 5 2 Force detection after mains switch on and after emergency release 5 3 Pulser control 5 4 Synchronising to end position CLOSED 5 5 Running time limit 5 6 Safety contact profile for gate OPEN SLA and for gate CLOSED SLZ 5 7 Safety contact profiles with 8 2kO terminating resistor 5 8 Photo cells 5 9 The photo cell testing 5 10 Timer mode 5 11 Pre warning warning light and traffic light 5 12 Radio remote control display 5 13 Multi functional relay 5 14 Service counter maintenance counter and maintenance interval 6 INITIAL START UP 6 1 Programming 6 2 Sequence P1 Learning of running distances 6 3 Sequence P2 Adjusting of force reserves and speeds 6 4 Sequence P3 Adjusting of dead man s function impulse mode 6 5 Sequence P4 Adjusting of partial opening position Heras productie maatschappij B V Delta_130607_UK R amp D Page 4 45 U
16. al opening position use BTG for closing If LS or SLZ is active during stay open time the stay open time still elapses further The gate closes when the time has elapsed and neither LS nor SLZ are active Automatic closure is blocked when BS is pressed The gate opens completely when BA is pressed The gate closes completely when BZ is pressed If channel 1 of the timer is activated the gate opens completely After mains switch on automatic closure 19 possible Heras productie maatschappij B V Gebr ET Odysseus Delta_130607_UK Page 22 45 13 6 2007 ee es A User Manual Odysseus Delta with motor type ET 46 3 Dead man s mode Dead man s mode can be selected in the learning sequence The buttons BA and BZ give no maintained command during dead man s mode The gate can be opened and closed manually using BA and BZ The gate moves as long as the button is pressed and stops when the button is released When BS is activated no gate movement is possible Photo cells are monitored and cause STOP SLA SLZ and Force are monitored and cause STOP und reversing for a short distance When LS SLA or SLZ report or when their testing is negative operation in emergency mode is possible e BT and BTG and the matching radio remote control have no function during dead man s mode 46 9 Emergency mode When BT BTG BA or BZ are pressed and the gate movement is prevented by a reporting or faulty LS or SLA or SLZ then the controller chang
17. ated again when the emergency release has been switched off e Insert the hexagonal key SW6 into the hole marked X and turn the mechanism 180 to the left The gear wheel is now located lower and the power supply of the controller is interrupted display E7 The height of the pinion axis is approx 87mm on delivery and can be altered 15mm if required Make sure that the opener can still be disengaged after adjusting the height Hexagon key HH SW6 EHE X Lh 04 cl s EHH CE Part to switch controller off O a Switch is off when Gear wheel F disengaged AL ZEN Adjustment of the motor Motorholder the height holder or 15 mm to the shaft middle is possible approx 87 mm on delivery 3 3 3 Infrared vehicle protection device in the gate opening optional This protection device prevents the gate closing when vehicles pass through the opening If the device is activated when the gate closes the motion of the gate will stop and it will open fully It is possible to resume closure of the gate when the opening 1s clear for automatic closing this will occur automatically after the pre set time The aforementioned mechanism is req
18. delivered in lengths of approx 500 mm Connect these elements and insert them into the aluminium profile The springs supplied will form the end of the rack on the left and on the right There is no warranty if the rack is used without these springs The toothrack holder needs to be fitted at both ends with springs and cover plates Use the cover plates as a template drill the holes 2 5mm and 8mm so that the toothrack holder is closed by the cover plates e Fit the first cover plate at one end with a spacer sleeve and affix the spring e Slide the toothracks into the toothrack holder until the first toothrack reaches the spring with cover plate e Pull the last toothrack back slightly out of the section and shorten this so that the second spring fits in the holder e Now fit the second cover plate with spring and cover plate and spacer sleeve Caution the springs should not be pressed too firmly EEE a Ba 8 ipo 9 gt a T A ere of L_ wal 7 C w ig T nr MD ir 38 LL A R E wi OT 82 5 mm WW S L 11 Heras productie maatschappij B V Gebr ET Odysseus Delta_130607_UK R amp D Page 9 45 13 6 2007 ei es C User Manual Odysseus Delta with motor type ET 2 2 Installating the motor unit e Loosen the 4 screws of the hood and remove the hood e Now you have access to all holes for cables and ground fixation e Place the opener with 65 mm distance from the gate with the back parallel
19. e 27 45 13 6 2007 Me es C User Manual Odysseus Delta with motor type ET 5 11 Pre warning warning light and traffic light The controller has potential free relay outputs for warning light red and green traffic light no one way control A pre warning time of 4 seconds duration prior to opening and closing can be selected see programming Gate status Red light Warning light Green light Gate closed Gate opened Pre warning or gate moving Gate stopped in intermediate position Gate stopped in partial opening off position 5 12 Radio remote control display The decimal point at the single digit on the display is lit when one of the learned radio remote control codes is received 5 13 Multi functional relay On the controller you find the relay MULTI which may be used for different application purposes During learning of the controller the relay is switched off see programming Heras productie maatschappij B V Gebr ET Odysseus Delta_130607_UK R amp D Page 28 45 13 6 2007 Me es C User Manual Odysseus Delta with motor type ET 5 14 Service counter maintenance counter and maintenance interval Prescaler Maintenance counter Gate cycle A gate cycle is the reaching of the end position CLOSED Service counter 32Bit Each time the gate reaches the end position CLOSED and synchronises the gate cycle is counted The maintenance counter is compared to the selected maintenance interval When the counter is
20. e OPEN User Manual Odysseus Delta with motor type ET with 8 2kOhm resistor o O Olesi S SIS o Transformator C 5 Gleichrichter o I ASU 2 I Steckplatz f r O m Wochenschaltuhr ar A O tern H L Obit Z o Uo N I O JBT IS ulti S o S ar Steckplatz fur Warn a 5 Funkempfanger Rot S a o 2 5 v O Gr n R LS Test ts SLA SLZ BTBGBABZ 88 K K A RARA B o RRR Q kd lede I P d 818 BoM Rom ROM ROM ROME ROM Bd 0 010 0 000 io O LEE ca E EE N Rie fete felis olg RR 1 I ilolo lt PE L1 N st amp REY O dF z So ous B o oO D ovo Mu 24V DC 30W 10 20 Ke N 11
21. e gate is not immediately known At first therefore only the running direction CLOSE with speed stage 1 is permitted The gate position is not known before the gate is closed completely and is switched off by force detection in the end position CLOSED The controller now switches over to normal mode Remark When after power failure emergency release an obstacle is present n the gate the controller identifies the obstacle as end position CLOSED If the gate is now A opened then it will pass over the end position OPEN So an emergency end stopper is needed at the end position OPEN It is now necessary to switch off and then on and another closing procedure has to be executed When automatic closure for complete and or partial opening is selected automatic closure follows after mains switch on With automatic closure for complete opening the stay open time for complete opening is used otherwise the stay open time for partial opening There is no automatic closure after emergency releasing 4 6 3 Control sequence by BT and or BTG in normal operation with self retain 4 6 3 1 Serial switching by BT and the associated radio remote control channel Without automatic closure for complete opening The gate can be operated by BT in serial switching OPEN STOP CLOSE STOP In case the gate is in the partial opening position BT is used for closing With automatic closure for complete opening When the gate is not in the end position OPEN then BT is
22. elta with motor type ET 6 3 Sequence P2 Adjusting of force reserves and speeds When sequence P2 is activated by button LERN an additional selection menu for force and speed opens With button BT you may move to different points of the selection menu with BTG you return to the previous sub sequence Sub sequence Function F1 Force reserve for opening F2 Force reserve for closing Speed for opening Speed for closing Return to the main sequence With the button LERN the selected point can be activated The present value for force F force or speed S speed is displayed Possible values are 01 for minimum force reserve up to 13 for maximum force reserve or 01 for minimum speed stage up to 08 for maximum speed stage With button BT the values may be increased with the button BTG they can be decreased Return to the learning sequence using button LERN Remark regarding the force reserve The force detection of the controller has a maximum value which must not be exceeded During learning of the running distance the controller determines the maximum motor current of the motor connected This also must not be exceeded The maximum force limit is the lowest value of force learned plus force reserve and the maximum force of the controller and the maximum force of the motor If the selected force reserve is so high that the maximum of the learned force value plus force reserve is higher than the maximum force of the controller or
23. er with decoder BIG BA BZ S B nn L DIS C U7 2 C N gt C gt gt G G u lt Z O Cp C IMP Power supply for the controller 230Vac L1 N PE Connection for the secondary winding of the main transformer J M JI Z TI lt s T 5 o lt 32 x m Heras productie maatschappij B V Gebr ET Odysseus Delta_130607_UK amp D Page 18 45 13 6 2007 Ee eli i l User Manual Odysseus Delta with motor type ET 4 4 2 Controller output terminals 2 blade terminals Connection for 24Vdc motor W P ake a rare emo re terminal 230V max 60W terminal 230V max 60W terminal 230V max 60W terminal contact max 230V max 60W Uext 3 pin screw plug 24Vdc and 12Vdc mutual ground terminal stabilised direct voltage together max 300mA ground terminal is connected with controller ground terminal terminal 1 pin screw Connection for the primary winding of the main terminal transformer 44 3 Buttons on the controller Function Same function as external button BT Same function as external button BTG Starting the learning mode ARN ED LERN nme L EVR da BTG L LM der RS T pe E SELES Le EIFEL HE FD T Heras productie maatschappij B V Gebr ET Odysseus Delta_130607_UK R amp D Page 19 45 13 6 2007 ee es C User Manual Odysseus Delta with motor type ET 4 4 4 Light display on the controller Vp Yellow _ Lights when connected to
24. es into emergency mode Here the warning light flashes for 10s Then the gate can be moved by BT BTG BA or BZ in dead man s mode even thought the safety device reports e Failure of a safety device means that the photo cell test or the safety contact profile test failed or that either one reports an obstacle e The operating buttons have to be installed at a location from which the gate can be seen during operation e Emergency mode by internal radio remote control is not possible e Force detection reaching of the end positions impulse failure detection and BS are still monitored and cause STOP e ATTENTION External equipment which gives a constant signal and is connected to BA or BZ can trigger the emergency mode and move the gate when a safety device failed or is activated e When the multi functional relay is used for an additional radio remote control channel and this is connected to BA or BZ the emergency mode can be triggered by radio remote control In this case only stationary transmitters are allowed from which location the gate can be seen 46 10 Emergency mode with automatic closure for complete opening by BT When the gate is not open it will be opened by BT When however a safety device for direction OPEN fails then pre warning before emergency mode is started and the gate is opened in emergency mode until push button BT is released Closing by BT in emergency mode with selected automatic closure is only possible from end
25. he motor unit are tightened Caution the emergency release must be secured in each position Heras productie maatschappij B V Gebr ET Odysseus Delta_130607_UK R amp D Page 10 45 13 6 2007 ee es C User Manual Odysseus Delta with motor type ET 3 Safety when using and during work in progress 3 1 Safety in general view of opening Despite all safety and precautionary measures the following aspects must be taken into account when using the gate e The direct vicinity of the gate must remain within view e While the gate is in motion it is strictly forbidden for any external object to come into contact with the gate so that it can NL HOUDT VOLDOENDE AFSTAND become obstructed l l l BIJ IN BEWEGINGZIJNDE POORT e Keep a safe distance when the gate is in motion Warning D WENN TOR IN BEWEGUNG IST AUSREICHENDEN ABSTAND HALTEN signs have been put in various places for this purpose See GB KEEP A SAFE DISTANCE WHEN THE Appendix B Placing Warning signs GATE IS INMOTION l F RESTEZ SUFFISAMMENT L CART e Keep the passage of the gate free of snow and ice DU PORTAIL LORSQU IL SE TROUVE EN MOUVEMENT l For gates with a dead man override often without safety precautions T i dN it must be possible to oversee the opening and the entire movement of K the gate 3 2 Safety during work in progress and when installing Safety regulations e Before using the gate for the first time the user must read the use
26. higher than the interval a maintenance notice is issued The prescaler for sliding gates is 1 1000 The prescaler is set automatically during learning of the maintenance counter The maintenance notice can be displayed on the multi functional relay Functions e Maintenance counter display and set to zero see programming e Maintenance interval display and setting see programming e Service counter display Start the controller while the LERN button is pressed After display of the program version the current service counter is shown as a sequence of 4 bytes in hexadecimal mode highest value first on the display Comparator gt Maintenance notice Maintenance interval Examples e 00000015 21 gate cycles e 00100bac 1 051 564 gate cycles The setting range for the maintenance interval is 0 no maintenance notice till 299 On the 2 digit display the numbers U to 299 can be displayed by using one decimal point for 100 and two decimal points for 200 Example e The maintenance counter shows 23 This is equal to 123 Thus the sliding gate has moved 123 x 1 000 123 000 cycles since the last maintenance e For the maintenance interval 0 3 is displayed This is equal to 203 The maintenance notice is issued when a sliding gate has moved 203 x 1 000 203 000 cycles In order to create the desired maintenance notice the following has to be selected during learning sequence 1 Operating mode sliding gate has to be selected
27. ime 123 seconds Automatic closure is activated Stay open time 223 seconds Automatic closure is activated After the desired time is selected push the LERN button to return to the learning sequence 23 Stay open time 23 seconds Automatic closure is activated Heras productie maatschappij B V Gebr ET Odysseus Delta_130607_UK R amp D Page 34 45 13 6 2007 ee C User Manual Odysseus Delta with motor type ET 6 9 Sequence P8 Warning prior to opening and closing When sequence PS is activated by button LERN the present value for warning time is displayed With the button BT the value can be selected Return to the learning sequence using button LERN Warning time before opening Warning time before closing 4 seconds warning time 4 seconds warning time No warning time 4 seconds warning time 4 seconds warning time 6 10 Sequence P9 Photo cell function When sequence P9 is activated by button LERN the present selection for the photo cell function is displayed With the buttons BT and BTG the desired function can be selected Return to the learning sequence using button LERN free again free again free again free again free again free again immediately 6 11 Sequence PA Photo cell testing on off When sequence PA is activated by button LERN the present selection for the photo cell testing is displayed With the button BT the mode can be selected Return to the learning sequence using button LERN Display Corresp
28. lf The appliance should only be used when all safety equipment is available and n working order All faults which might present a source of danger to the user or to third persons must be eliminated immediately All Warning and Safety notices on the appliances must be clearly legible All electrically operated peripheral devices which are connected to the appliance must have a CE Mark which ensures that they conform to the relevant EEC regulations Neither mechanical nor electrical alterations to the appliance without the explicit agreement of the manufacturer are permitted All alterations or extensions to the appliance must be carried out using parts which the supplier has defined as suitable for such alterations and be carried out by qualified personnel Any contravention of these conditions revokes the manufacturer s guarantee and also the CE Mark and the user alone is responsible for the consequences Our service department is available to answer all queries about these conditions and of course about our appliances The operation of the system within CEN countries must also conform with all relevant European safety directives and standards Heras productie maatschappij B V Gebr ET Odysseus Delta_130607_UK R amp D Page 14 45 13 6 2007 ee es C User Manual Odysseus Delta with motor type ET 4 Installing and operating the gate 4 1 Controller MO 46 Connection plan for controller MO 46
29. main power 2m BT Green een reen Lights when LS is interrupted 2 digit 7 segment display ii ii Q Vp BT Display joe i S 7 5 urun pa Ls Test IS SLA SLZ BTBGBABZ BS Yipee BAR 4 5 Operation The drive works in sequential logic over serving tracer BT or radio controller 1 actuation the drive starts 2 actuation the drive stops 3 actuation the drive starts in opposite direction 4 actuation the drive stops 4 6 Operational characteristics 46 1 Electrical installation Again make sure that the rack is mounted correctly and that all screws of the rack and the drive are firmly tightened Check the position of the rack during start up adjust the height of the drive if necessary The use of the emergency release must be guaranteed in every gate position If the gate closes to the left as viewed from the gate opener switch the red and the green motor connection wire on the controller Heras productie maatschappij B V Gebr ET Odysseus Delta_130607_UK R amp D Page 20 45 13 6 2007 ee C User Manual Odysseus Delta with motor type ET 4 6 2 Perfomance after main switch on and emergency release When the controller is switched on the exact position of th
30. ng amplifier is faulty Heras productie maatschappij B V Gebr ET Odysseus Delta_130607_UK R amp D Page 39 45 13 6 2007 ee C User Manual Odysseus Delta with motor type ET 8 Use and technical specifications of the gate 8 1 Description of sliding gate The gate is to seal off the site perimeter This manual refers to powered cantilever sliding gates Leaf Odysseus Delta Length m 5 05 11 55 5 15 12 5 Height m 1 0 2 5 1 0 3 0 Max weight kg 125 120 Runner wheels Steel PA6G210 cantilever Cantilever 8 2 Technical data Soft start and Soft stop Yes Evaluation of safety contact Haan 7 Integrated strips Heras productie maatschappij B V Gebr ET Odysseus Delta_130607_UK R amp D Page 40 45 13 6 2007 ee C User Manual Odysseus Delta with motor type ET 8 3 Measurements All measurements are quoted in mm Heras productie maatschappij B V Gebr ET Odysseus Delta_130607_UK R amp D Page 41 45 13 6 2007 ee es C User Manual Odysseus Delta with motor type ET Appendix A Installation of personal protection device Below are the guidelines for the installation of the personal protection devices on the sliding gate The diagram shows the gate when viewed from above Explanation of symbols I Personal protection strip ss Motor unit ee Line of mesh fencing Odysseus gate with gateposts 4x active 1x passive See eins Outside saiya svosedsaedustvvsvasonecbarvcutvnyseceslcsucevsceusee
31. not used the corresponding terminal has to be connected to ground by an 8 2kQ 5 resistor More than one safety contact profiles with 8 2kQ terminating resistor can be switched in series as shown in the drawing below The safety category remains the same Terminating profil 1 profil 2 u SLA SLA 5 8 Photo cells A system of up to 6 photo cells can be connected to the controller The functions of the photo cells depend on their selected mode see learning sequence Heras productie maatschappij B V Gebr ET Odysseus Delta_130607_UK R amp D Page 26 45 13 6 2007 ee C User Manual Odysseus Delta with motor type ET 5 9 The photo cell testing Before each gate movement for which the photo cell is monitored a photo cell testing is performed It consists of two parts During the first part the transmitter of the photo cell is switched off S1 S6 and it is waited for the receiver E1 E6 to report an obstacle within max 2 5s Then the second part starts Here the transmitter 1s switched on and it is waited for the receiver to report no obstacle present After this the gate starts moving If there is a failure during the first part the photo cell 1s faulty Error code E1 is displayed In case of a failure during the second part it is assumed that an obstacle is present within the photo cell range and the gate will not move No error code is issued Up to 6 photo cells can be connected to the controller and can be tested Fo
32. onds to Photo cell testing is deactivated Photo cell testing is activated This function is only possible when the photo cells have passed the LS Test during the learning sequence Heras productie maatschappij B V Gebr ET Odysseus Delta_130607_UK R amp D Page 35 45 13 6 2007 Me es C User Manual Odysseus Delta with motor type ET 6 12 Sequence PB Delayed closure off When sequence PB is activated by button LERN the present selection is displayed With the button BT the mode can be selected Return to the learn ng sequence using button LERN A close command by BZ is executed immediately A close command by BZ is stored and will be executed when the end position OPEN or partial opening is reached Note this function is not possible in dead man s mode 6 13 Sequence PC Maintenance counter indication and deletion When sequence PC is activated by button LERN the current maintenance counter reading is displayed The maintenance counter reading s deleted by pressing the BT button and additionally the LERN button Then return to the learn ng sequence using button LERN If only the LERN button is pushed you return to the learning sequence without changing the maintenance counter reading The decimal points on the display are each equal to 100 Display Cycles for a sliding gate example Prescaler 1 1000 23 x 1000 23 000 cycles 23 123 x 1000 123 000 cycles 2 3 223 x 1000 223 000 cycles
33. r manual in full The safety regulations in the manual must be observed at all times Improper use can lead to unexpected hazards and 19 therefore forbidden e When the gate is being installed the mains switch needs to be set to the OFF position and protected against unauthorised activation e If the gate needs to be operated manually the isolation device in the motor unit must be set to the OFF position and secured This can be done by allowing the toothed wheel of the motor unit to drop using a hexagonal ey to prevent activation e Ensure that motor unit is always closed during use The motor unit must only be opened by a technician with electro technical qualifications For Heras gates the following applies Safety takes precedence over Control and Opening takes precedence over Closing Heras productie maatschappij B V Gebr ET Odysseus Delta_130607_UK R amp D Page 11 45 13 6 2007 hi 3 3 Safety precautions on the gate e C User Manual Odysseus Delta with motor type ET 3 3 1 Personal safety and regular inspection Depending on the configuration of the gate and the adjacent fencing safety strips will be affixed at various points where there is a risk of entrapment See Appendix A Installation of personal protection device The safety strips should be inspected visually regularly once a month to check that they are undamaged and work properly The procedure for inspection is as follows
34. r this purpose the relay outputs of the receivers are switched in sequence Parallel to the relay contacts of each receiver a resistor of 1kOhm 5 MUST be connected Attention During learning of fe ft the running distance the controller executes a photo u cell testing and learns f and i S2 fe ft how many photo cells are connected If the photo cell testing during learning was successful a photo cell g S3 n T testing can also be executed later during normal operation If the photo cell testing during learning was not successful no photo cell testing will be g S6 n executed later during normal a operation Important After learning the installing technician has to check every single photo cell for functioning 5 10 Timer mode The timer ASU2 can be plugged onto the controller The timer has two channels with the following functions When channel one of the ASU2 is switched on this is equal to an OPEN command As long as channel 1 of the ASU2 is on the gate cannot be closed When channel 1 of the ASU2 switches off this is equal to a CLOSE command When automatic closure is selected the gate closes immediately when channel 1 of the ASU2 is switched off and does not wait for automatic closure The channel 2 of the ASU2 can be displayed on the multi functional relay The potential free relay may then be wired e g to any operation inputs Heras productie maatschappij B V Gebr ET Odysseus Delta_130607_UK R amp D Pag
35. rning sequence P5 6 6 Sequence P5 radio remote control for BT BTG and MULTI When sequence PS is activated with the button LERN an additional selection menu is displayed for selecting the code With button BT you may move to the next points of the selection menu with BTG you return to the previous sub sequence Radio remote control code for BT can be learned or deleted Radio remote control code for BTG can be learned or deleted Radio remote control code for MULTI can be learned or deleted Return to main sequence Sub sequence is activated with button LERN The display shows Display Corresponds to il The selected radio remote control code is deleted and another can be learned The selected radio remote control code is already stored and can be overwritten or deleted To learn a code the transmitter has to be operated The code will then be stored and you will return to the sub sequence To erase the radio remote control code press and hold the button BT and additionally push the button LERN The radio remote control code is erased Return to the sub sequence follows automatically If only the button LERN is pushed then return to the sub sequence follows immediately without erasing the code Remark The stored codes must be different from each other Heras productie maatschappij B V Gebr ET Odysseus Delta_130607_UK R amp D Page 33 45 13 6 2007 ei es C User Manual Odysseus Delta with motor type ET 6 7 Seq
36. s Delta_130607_UK R amp D Page 37 45 13 6 2007 Me es C User Manual Odysseus Delta with motor type ET 6 15 Sequence PE Mode for multi functional relay When sequence PE is activated by button LERN the present selection is displayed Using BT and BTG the required mode can be selected Return to the learning sequence using button LERN During programming of the controller the relay is shut off Remote control Therelay is active as long as the controller push button mode l receives the radio remote control code MULTI Remote control The relay alternates between active and de toggle mode active with each radio remote control code MULTI Light pulse mode The relay is active for 1 second when BT Funk BT BTG Funk BTG BA or BZ are pushed Timer channel 2 When channel2 of ASU2 is switched on the relay is active Maintenance When maintenance is required the relay is Errors activated When certain error codes occur for which maintenance or repair is required the relay alternates between active and de active in one second intervals 3 minute light The relay is active for 180 seconds when BT Funk BT BTG Funk BTG BA or BZ are pushed 6 16 Sequence PF Return to original settings When sequence PF is activated by button LERN rE is displayed To return to original settings press and hold button BT and push button LERN When only button LERN is pushed you return to learning sequence without changing any values Af
37. see learning sequence P1 2 The maintenance interval has to be set to the desired value see learning sequence PD 3 The multi functional relay has to be set to the mode maintenance notice see learning sequence PE r6 4 The maintenance counter has to be set to zero see learning sequence PC Heras productie maatschappij B V Gebr ET Odysseus Delta_130607_UK R amp D Page 29 45 13 6 2007 ee es C User Manual Odysseus Delta with motor type ET 6 Initial start up The controller is connected as indicated in the section on Electrical installation In the learning sequence the desired speed must be selected and the running distance learned 6 1 Programming For programming and to set operating parameters use the two digit 7 segment display and the buttons BT BTG and LERN Learning sequence During normal operation the display is off The learning sequence 19 activated by pushing the button LERN for approx 2 3s The display shows Pl The sequence 1 is pre set With the button BT you can move on to the next sequence P2 P3 etc With the button BTG you can move back to the last sequence When the required sequence is displayed it has to be activated with the button LERN Setting the mode Slide gate Reserve Learning of safety contact profiles and photo cells connected Learning of running distance and force Adjusting of force reserves and speeds Adjusting of dead man s function impulse mode Adjusting of au
38. ser Manual Odysseus Delta with motor type ET 20 20 21 21 22 22 22 23 23 23 24 25 25 25 25 25 25 26 26 26 27 27 28 28 28 29 30 30 31 32 32 33 Gebr ET Odysseus 13 6 2007 ee C User Manual Odysseus Delta with motor type ET 6 6 Sequence P5 radio remote control for BT BTG and MULTI 6 7 Sequence P6 Automatic closure for complete opening 6 8 Sequence P7 Automatic closure for partial opening 6 9 Sequence P8 Warning prior to opening and closing 6 10 Sequence P9 Photo cell function 6 11 Sequence PA Photo cell testing on off 6 12 Sequence PB Delayed closure off 6 13 Sequence PC Maintenance counter indication and deletion 6 14 Sequence PD Adjusting maintenance interval 6 15 Sequence PE Mode for multi functional relay 6 16 Sequence PF Return to original settings 7 FAULT DIAGNOSIS BY THE CONTROLLER 8 USE AND TECHNICAL SPECIFICATIONS OF THE GATE 8 1 Description of sliding gate 8 2 Technical data 8 3 Measurements APPENDIX A INSTALLATION OF PERSONAL PROTECTION DEVICE APPENDIX B PLACING WARNING SIGNS APPENDIX B EC DECLARATION OF CONFORMITY 33 34 34 35 35 35 36 36 37 38 38 39 40 40 40 41 42 43 44 Heras productie maatschappij B V Gebr ET Odysseus Delta_130607_UK R amp D Page 5 45 13 6 2007 ei es C User Manual Odysseus Delta with motor type ET Heras productie maatschappij B V Gebr ET Odysseus Delta_130607_UK R amp D Page 6 45
39. sition result is distance stop and opening After two attempts to close by automatic closure or without automatic closure at the OPEN position or during dead man s mode only stop and reversing for a short distance 5 2 Force detection after mains switch on and after emergency release Since after mains switch on the gate position is not known the maximum value of the learned force during closing is used as value for force detection 5 3 Pulser control When the pulser fails the controller reaction is the same as with force detection Additionally an error code is issued and the controller 1s blocked 5 4 Synchronising to end position CLOSED The force detection normally causes short reversal However within the synchronising area short distance before end position CLOSED the controller evaluates the force detection correctly not as an obstacle but as end stopper Only STOP occurs but no short reversal follows The internal position counter is being synchronised to the end position 5 5 Running time limit The end position OPEN is reached by impulse counting A running time limit is not necessary The controller always stops at the calculated position In the end position CLOSED synchronisation occurs by force detection In case of no force detection at the calculated position automatic stopping after a running time reserve follows The controller issues an error code and then it blocks Heras productie maatschappij B V Gebr E
40. ter returning to original settings the running distance has to be relearned Heras productie maatschappij B V Gebr ET Odysseus Delta_130607_UK R amp D Page 38 45 13 6 2007 LW S 0 User Manual Odysseus Delta with motor type ET 7 Fault diagnosis by the controller Error code on the display and on the multi functional relay An error is shown on the display as a code and also on the multi functional relay if applicable when detected by the controller The following errors are recognised and displayed Code onthe Error code on 1 Error description the multi functional Photo cell testing failed Testing SLA failed Testing SLZ failed Running distance control stopped the gate Check end stoppers and re learn the running distance The power supply Uext 12V exceeds the permitted limit Too much power is withdrawn The controller is blocked The power supply Uext 2V exceeds the permitted limit Too much power is withdrawn The controller is blocked Yes Yes Yes Data on memory is faulty The controller must be relearned Select learning sequence and program the controller again Possible cause 1 The pulser is faulty Check the wiring of the gate opener 2 The motor is blocked Check the installation Return controller for repair Possible cause Error in storing of data on controller memory Error found in the redundant detection of BS Error found in the power element Either a motor relay or a semi conductor or a measuri
41. the maximum force of the motor then the display shows a decimal point in addition to the force reserve stage This indicates that the selected force reserve cannot be reached anymore and is in fact lower 6 4 Sequence P3 Adjusting of dead man s function impulse mode When sequence P3 is activated by button LERN the present value displayed The desired value can be selected using button BT Return to the learning sequence using button LERN The controller operates in dead man s function SH The controller operates in impulse mode Remark It is possible to select dead man s function and automatic closure together or dead man s function and delayed closure etc but automatic closure delayed closure etc are not active during dead man s function even when they are selected Heras productie maatschappij B V Gebr ET Odysseus Delta_130607_UK R amp D Page 32 45 13 6 2007 ei es C User Manual Odysseus Delta with motor type ET 6 5 Sequence P4 Adjusting of partial opening position Sequence P4 can only be activated when the gate position is known After switching on the power supply the gate must first be closed After activating sequence P4 HA is displayed Now the gate can be moved in dead man s function using BT first slowly then fast towards the desired partial opening position Then press the LERN button The current position is saved for partial opening After this you return automatically to the lea
42. there is no one in the danger area during learning After pushing the LERN button HA is displayed Now the gate can be moved in dead man s operation using button BT into the position which during normal operation corresponds to end position OPEN but not against the stopper GATE OPEN distance approx 5cm After this push the button LERN to continue learning the distance and force The display now shows AU The controller performs a test of the safety contact profiles and photo cells and learned the type of safety contact profiles and the quantity of photo cells connected Only if the photo cell testing has been successful can it be performed later during normal operation Now the gate closes in slow mode and shuts down at the end stopper CLOSED via force detection of the controller The maximum breaking current for the motor n use is determined in the process The running distance in impulses is also learned Remark Since the gate hits the end stopper CLOSED harder than in normal operation a correction value is deducted from the running time Now the gate opens and the force for opening is learned Then the gate closes and the force for closing is learned After this you return automatically to the learning sequence Remark After learning of the running distance the force reserve is automatically adjusted Heras productie maatschappij B V Gebr ET Odysseus Delta_130607_UK R amp D Page 31 45 13 6 2007 ee es C User Manual Odysseus D
43. tomatic closure activating deactivating and stay open time for complete opening P7 Adjusting of automatic closure activating deactivating and stay open time for partial opening Learning and deleting the radio remote control codes and deleting the radio remote control codes for BT BTG and MULTI P4 ___ Adjusting of partial opening position pa Selecting of waning prior to opening andcosng po Selecting photo cellfunction _ BA Activating deactivating phoio cellesting SSS pB Delayed closure activating deactvating DD pp Sekoingotmaintenancemter PE Seting mode of multtunctional reay pF Retum 10 aana same O oO PP Saving of data and returning 1o regular made DL Heras productie maatschappij B V Gebr ET Odysseus Delta_130607_UK R amp D Page 30 45 13 6 2007 ee C User Manual Odysseus Delta with motor type ET 6 2 Sequence P1 Learning of running distances When sequence Pl has been activated first the operating mode sliding gate has to be selected using button BT Then confirm the selection with button LERN If the sequence is activated by mistake use BTG to return to the main menu without changing any data Effect Function ee Operating mode Slide gate Operating mode Reserve ATTENTION The operating mode SLIDE GATE has to be selected display Illl ATTENTION During learning the safety devices may act differently from the regular operation Please ensure that
44. uence P6 Automatic closure for complete opening When sequence P6 is activated by button LERN the present value for stay open time for 66 complete opening is displayed or when automatic closure for complete opening is not active The automatic closure can be activated using the button BT and the value can be increased Using button BTG the value can be decreased and automatic closure can be deactivated The stay open time can be selected from Ols to 299s The decimal points of the display are each equal to 100s example Automatic closure is deactivated Stay open time 123 seconds Automatic closure is activated Stay open time 223 seconds Automatic closure is activated After the desired time has been selected push the LERN button to return to the learning sequence 99 Stay open time 23 seconds Automatic closure is activated 6 8 Sequence P7 Automatic closure for partial opening When sequence P7 is activated by button LERN the present value for stay open time for partial 66 66 m m opening is displayed or when automatic closure for partial opening is not active The automatic closure can be activated using the button BT and the value can be increased Using button BTG the value can be decreased and automatic closure can be deactivated The stay open time can be selected from Ols to 299s The decimal points of the display are each equal to 100s example Automatic closure is deactivated Stay open t
45. uesdvd cevybsvouenetivesieustvecsnessddesbeestenen open s x s s 4 passive Delta gate with gateposts 9x active ee Outside A E EN ES OEER ER TTEIF RATE i open Heras productie maatschappij B V Gebr ET Odysseus Delta_130607_UK R amp D Page 42 45 13 6 2007 ee 0 User Manual Odysseus Delta with motor type ET Appendix B Placing Warning signs NL HOUD VOLDOENDE AFSTAND iN PODAT ST F RESTEZSUFFISAMMENT LECART DU PORTAIL LORSQUIL SE TROUVE UUU HERAS Heras productie maatschappij B V Gebr ET Odysseus Delta_130607_UK R amp D Page 43 45 13 6 2007 ee es C User Manual Odysseus Delta with motor type ET Appendix B EC Declaration of conformity Heras Fencing Systems B V Hekdam 1 5688 JE Oirschot hereby declares that the sliding gate hereinafter described conforms to the requirements of the committee made on 14 June 1989 in respect of the standardization of the machine directives of the member states and the accompanying modification directives Type of sliding gate Odysseus Delta ET installation 98 37 EG Machinery Directive EU directives applicable 73 23 EEG Low Voltage Directive 89 336 EEG EMC Directive electro magnetic compatibility Harmonised standards applicable EN 12100 1 EN 12100 2 EN 61508 2001 NEN EN 1050 1996 EN 60335 1 2002 EN 954 1 1996 EN 12978 2003 EN 1760 2 EN 12604 2000 EN 60204 1 1997 EN 12605 2000 EN 61000 6 3 2001 NEN 6770 EN 61000 6 1 2001 NEN 6771 EN 12453 20
46. uired to be checked every month Heras productie maatschappij B V Gebr ET Odysseus Delta_130607_UK R amp D Page 13 45 13 6 2007 ee es C User Manual Odysseus Delta with motor type ET 3 34 General notes of safety These operating instructions must be available on site at all times They should be read thoroughly by all persons who use or service the appliances Improper usage or servicing or ignoring the operating instructions can be a source of danger for persons or result in material damage If the meaning of any part of these instructions is not clear then please contact your supplier before you use the appliance This applies to all set up procedures fault finding disposal of material care and servicing of the appliance The accident prevention regulations applicable technical regulations e g safety or electrical and environmental protection regulations of the country in which the appliance is used also apply All repairs on the appliances must be carried out by qualified persons The supplier accepts no liability for damage which is caused by using the appliance for purposes other than those for which it is built The supplier cannot identify every possible source of danger in advance If the appliance is used other than in the recommended manner the user must ascertain that no danger for himself or others will result from this use He should also ascertain that the intended use will have no detrimental effect on the appliance itse

Download Pdf Manuals