Home
Kullanım Kılavuzu
Contents
1. STANDING UNPERMITTED ENTRY If authorized person stands on the lane while passing the entry will be unpermitted After 15 seconds the warning buzzer will be on and in 5 seconds if the passage is not done the wings will be closed Authorization will not be valuable If the standing is done on the other side of wings he she can end the passings And if the standing is done between the wings for safety regulatons the wings will not be closed and warning buzzer will be on in the same way Makim Makine Teknolojileri A S All rights reserved 9 Kullanim Kilavuzu 5 CONTROL PANEL AND CONTROL PANEL PARTS PART NO EXPLANATION P B00A0738 BUZZER DASHED 24V AURAL WARNING A00B277 1 HIDDENGATE ELECTRONIC CARD V 01 4 5A EES 9400 SIX MEGA KLEMENS JOINTER C00A1693 V AUTOMAT RAIL 190mm A00B1477 TEN MEGA RADAR KLEMENS JOINTER ee ee OOOOOOOOOOOOCO T DOOOOOOOOOOOO S e202 03080506 0708 9030 K 5 s s C1 Led2 Switch Giri i D1 Motor2 Klemens Girisi C2 Led2 Switch Girisi D2 Motor2 Klemens Girisi T Toprak Led2 Switch Girisi D3 Sens r 24 V Girisi N Notr C4 Led1 Switch Girisi D4 Sens r 24 V Girisi L Faz C5 Led1 Switch Girisi D5 Encoder2 K 24V C6 Led1 Switch Girisi D6 Encoder2 S 24V D7 Encoder2 K 24V D8 Encoder2 S 24V D9 nan Makim Makine Teknolojileri A S All rights reserved Kullanim Kilavu
2. Makine Teknolojileri A All rights reserved Kullanim Kilavuzu 3 T300 HG120 TECHNICAL SPECIFICATIONS Dimensions Width 350mm Lenght 1450mm Height 1187mm System Motorized Direction Bidirectional entry and exit from both sides Material Top Covered Wooden Standard Stainless Steel Top Optional Special Patterned Glass Top Optional Body AISI 304 EN 1 4301 Stainless Steel AISI316 EN 1 4401 Optional AISI316L EN 1 4404 Optional Chassis 3mm HRP ST37 Galvanized amp PowderCoated Wings 15 mm Plexyglass Emergency In case of emergency earthquake fire etc Wings are opened to sides by hand When electricity is on hiddengate will start operating itself again Operating Voltage 24V DC Power Consumption 115 230 VoltsAC 50 60 Hz 300 VA Passage Times 15 20 person min Weight 90 IP Protection IP 42 Makim Makine Teknolojileri A S All rights reserved Kullanim Kilavuzu 4 T300 HG120 FEATURES 4 1 LANE ALTERNATIVES For the hiddengate type of turnstiles you should arrange the lanes shown as below in order for people to pass SINGLE LANE Two single hiddengate 1 mechanism flap turnstile creates 1 bidirectional lane Control panel could be entegrated in either one we s s s LL m m m s s s s s DOUBLE LANE 2 single and 1 double hiddengate creates two bidirectional lanes There will be two control panels
3. You could either entegrate control panels to 2 single units or both control panels to double unit ea ee u MULTIPLE LANES On the left picture 4 lanes are shown created with 2 single and 3 double units Makim Makine Teknolojileri A S All rights reserved Kullanim Kilavuzu MULTIPLE LANES Control panel locations are shown in above picture You can increase lane quantity like that single double double single During installation give the electricity to the unit with contol panel Dashed lines between two units indicates the cables for connection 4 2 SYMBOLS Symbols indicates the passege permission to the user There are fixed led symboles for entry and exit situations showing passage direction on each unit e Red Cross Light Passage is not permitted until successful authorization e Green Arrow Light Successfully authorized and permitted to passage Makim Makine Teknolojileri A S All rights reserved Kullanim Kilavuzu e Orange Dashed Line Light Everything 1s normal awaiting for authorization for passage W 4 3 WORKING PRINCIPLE Main board which is managing the hiddengate receives commend for passage and if all the conditions are fulfilled the wings are opened Passings can be both one by one and ensuingly If more than one authorizations are given those will be added to the memory and the same quantity of passages will
4. be allowed For this 30 people can pass ensuingly If the hiddengate detects no body even after authorization is given a warning buzzer will be on after 15 seconds and 5 more seconds will be given After this 5 seconds the authorization will be cancelled 4 4 UNAUTHORIZED ENTRY Unauthorized entries are not permited for passage During unauthorized passages the warning buzzer wil be on and the symbols will be red cross The wings keep closed Upon the cause of element for unauthorized passage is disappeared the hiddengate will turn to its standard mode WAITING UN PERMITIED ENTRY When the hiddengate is on normal waiting mode if anyone get into passage area without authority the sensors will detect and in 3 seconds the warning buzzer will be on Makim Makine Teknolojileri A S rights reserved mJ Kullanim Kilavuzu Un Permitted Entry Following Authorized Passage Optional While the authorized person is passing through another person follows without permission and this 15 unauthorized passage The passage could be done but the warning buzzer will be on REVERSE DIRECTION UNPERMITTED ENTRY When authorized person 15 on the right direction and unauthorized another person is on the reverse way this causes unpermitted entry Wings will be closed to both ways in this situation and warning buzzer will be on If unauthorized person leaves the lane the wings will be opened for authorized one
5. Makim Makine Teknolojileri A S All rights reserved Kullanim Kilavuzu 8 PROBLEM AND SOLUTION the power plug is on hiddengate Leds do not give light 2 Interior power cable 1s 2 Check interior power eNo movement on the not on cable hiddengate 3 Blowing of fuse 3 Change the blow e Power is received but 1 There is a problem 1 Wings are checked when wings do not work preventing wings they are released Be careful movement not to make it touch to plate Wings work but no voice 1 Buzzer 15 failed 1 Change the buzzer is heard 2 Buzzer plug is off 2 Check the buzzer plug 3 System 15 working 3 Check the system faulty e Wings stay open 1 There may be preventing 1 Check it by hand Jamming while closing 2 There may be fault on 2 Check the program the program 3 There may be fault on 3 Change the sensors the sensors e Wings do not open Sensors may not see Sensors must be checked although permission is eachother as to see eachother well given with green arrow sign e Hiddengate does not 1 Program may be faulty 1 Renew the program reset itself after the specified time of passage 2 Change the card permission is ended No 2 Card may be faulty passage direction info is seen after the passing is done Buzzer contiunously 1 Sensors do not see 1 It may be because of gives alarm when the eachother dust clean the plexyglass wings are cl
6. engate away from extremely hot and febrile environments Extreme heat may cause failure in the system Do not operate the hiddengate for long time under direct sun light Hiddengate should not be used in high magnetic fields Do not expose the hiddengate extreme water Do not operate 1 under direct rain 2 HIDDENGATE USAGE INSTRUCTIONS Hiddengate is designed for only one person passage each time More than one person should not try to pass the lane at the same time In the event of the system not working thoroughly actions posing danger to the system must be avoided In the event of any failure in order to prevent more harm to the hiddengate ungear the system or do not use it As the hiddengate will not detect any object not higher than itself it could be closed to the user in this case Do not wait for long time on the passage lanes Avoid from violent passings through hiddengate do not turn to sides while passing For unaccompanied children animals and objects like street toy cars there may come the buzzer voice Only with accompany of adults will the hiddengate be opened All operations on the equipments must be done by technical personnel Any failures caused by unauthorized people or non technical personnel will be out of warranty coverage of manufacturer Manufacturer does not accept any responsibility for the failures or woundings occured because of not confirming to the above specified Safety and Usage Instructions Makim
7. he packaged hiddengate on a wet floor Carry the hiddengate on an elevator suitable for its weight Before you start mounting check if any damage occured while carriage if the parts for mounting and connections are all ready 7 HIDDENGATE MAINTENANCE INSTRUCTIONS The maintenance suggestions and times here are only given with aim of general information and example It is advised for the user to decide the maintenance according to the usage environment and climate conditions Do not use corrosive chemical matters while doing maintenance While cleaning sensor Windows use a clean dry fabric and do not make any compress Outer steel body can be cleaned with a wet fabric once in month External connection screws must be checked visually once in every three months If you detect any relaxation on the screws contact with the seller agent or manufacturer Periodical maintenance of the hiddengates must be done by authorized service personnel If any need occurs you can contact the manufacturer and receive information about periodical maintenance Maintenance to be done by authorized service or seller agent PART TIME OPERATION Top and Buttom Bearings of 4 Months Oiling the Wings Floor Mounting Screws 6 Months Control Mechanism Screws 6 Months Control Engine 12 Months Control Electronic Card 12 Months Control Cleaning Sensor 12 Months Control Cleaning Cable Connections and 12 Months Control Sockets
8. nd we advise you to read this manual carefully in order to use the machine longer time without problem Please keep the user manual to benefit when need arises 1 HIDDENGATE SAFETY INSTRUCTIONS Before you install and use the hiddengate please read all the safety and maintenance instructions carefully Turnikenizi kurmadan ve kullanmadan Once t m g venlik ve bak m nerilerini dikkatle okuman z tavsiye ederiz You should read the user manual before installing the hiddengate For safety reasons don t open the hiddengate yourself Maintenance must be done only by the authorized service or the seller agent The modifications made by user might pose danger fort he machine and people Deformed hiddengates should not be operated and authorized service must be indormed immediately Specified power and voltage values in the technical specifications part must be adapted Before you energize the hiddengate after any deformation or maintenance check the accuracy of power supply and control card connections Use the parts and accesories approved by manufacturer compay In case of any problem cut off the electricity connections of turnstile and inform the authorized service Cut off the electricity connections while doing maintenance and cleaning Otherwise it may pose danger for the attending person Use moist duster while cleaning the hiddengate Dangerous materials for hiddengate should not be used with aim of cleanence Keep hidd
9. of control systems Part 1 General principles dor design e TS EN 1037 safety of machinery Prevention of unexpected start up e TS EN 61000 6 2 Electromagnetic compatibility EMC Part 6 2 Generic standarts Immunity for industrial environments e TS EN 61000 6 4 Electromagnetic compatibility EMC Part 6 4 Generic standarts Emission standarts for industrial environments e 15 3033 EN 60529 Degrees of protection provided by enclosures IP code for electrical equipments e EN 60204 1 Safety of machinery Electrical equipment of machines Part 1 General requirements and following the provision of e 98 37 AT Machinery 98 37 EC e 73 23 AT Low voltage equipment 73 23 EEC 93 68 EEC 93 68 EC Electromagnetic compability 89 336 EEC 92 31 EEC 93 68 EEC 98 13 EEC Directives Date 03 01 2011 Place ANKARA Name Tacettin ILER General Manager Signature Makim Makine Teknolojileri A S rights reserved
10. osed 2 Sensors are faulty 2 Change the sensors Wings stay in half 1 Check by hand if they opened position chassis work or not mechanism parts and oil them Makim Makine Teknolojileri A S All rights reserved Kullanim Kilavuzu 847 02 20 asura M EC DECLERATION OF CONFORMII Y MAKIM MAK NA TEKNOLOJ LER SAN VE A S Sincan OSB Erkunt Cad No 20 Sincan ANKARA Tel 90 312 267 56 87 Faks 90 312 267 56 99 E mail info makim com tr satis makim com tr Web www makim com tr We Makim Makine Teknolojileri San Ve Tic A S declare under our sole responsibility that the product Hiddengate Machine Model T300 HG120 Motorized Hiddengate Turnstile Production Tape 2011 to which this decleration relates is in conformity with the following standarts and other normative documents e TSEN 1050 safety of machinery Principles for risk assesment e TS EN 12100 1 Safety of Machinery Basic Concepts General Principles for Design Part 1 Basic Terminology Methodology e TS EN 12100 2 Safety Of Machinery Basic Concepts General Principles Fors Design Part 2 Technical Principles And Specifications e TS EN 953 safety Of Machinery Guards General requirements for the design and construction of fixed and guards e TS EN 294 safety of machinery Safety distances to prevent danger zones being reached by the upper limbs e TS EN 981 safety of machinery e TS EN 954 1 Safety of machinery Safety related parts
11. pa Eva Eve TURNSTILES amp ACCESS CONTROL SYSTEMS CO ma PREZ 1300 HG120 TURNSTILE INSTALLATION AND USER MANUAL VERSION V2 00 OCAK 2012 ANKARA Kullanim Kilavuzu suse save CONTENTS BEFORE YOU START HATA YER SARET TANIMLANMAMIS 1 HIDDENGATE SAFETY INSTRUCTIONS 3 2 HIDDENGATE USAGE INSTRUCTIONS 3 3 1300 HG120 HIDDENGATE TECHNICAL SPECIFICATIONS 4 4 1300 HG120 FEATURES U 5 4 1 LANE ALTERNATIVES aim ed sixsaaivsduss aus 5 42 9T MBOLS Zuna 6 4 3 WORKING PRINCIPLE 7 4 4 UNAUTHORIZED ENTRY 7 5 CONTROL PANEL AND CONTROL PANEL PARTS 9 5 1 T300 HG120 ELECTRONIC CARD 10 5 2 POWER SUPPLY AND SAFETY INSTRUCTIONS 10 5 2 POWER SUPPLY sector uu anna 10 6 T300 HG120 HIDDENGATE MOUNTING INSTRUCTIONS 11 7 HIDDENGATE MAINTENANCE INSTRUCTIONS 11 Makim Makine Teknolojileri A S All rights reserved Kullanim Kilavuzu 10 11 12 13 ee FRM EHE BEFORE YOU START Thank you for purchasing T300 HG120 Motorized Turnstile a
12. to be mounted on and if it 1s not straight it must be straightened 3 Mark the holes to be mounted on the floor Be careful to locate the units on a line Otherwise the hiddengate sensors will not detect eachother mutually and this will prevent the units operating 4 Drill the marked holes with 10 twist bit and clean the dust inside the holes with help of air PICTURE 4 5 Locate the fixing plugs in the holes by joeing If the floor is not solid joe the fixing plugs after pouring chemical grout and wait 20 min for the grout to freze Suggested Chemical Grout is Hilti HIT HY 150 6 Previously prepared power and data cables are passed through the cable passing points on the hiddengate platform 7 Hiddengate platform is put on the steel plugs and fixed to the floor with shims and nuts 6 Below you can see the pictures about mounting of the plug and hiddengate to the floor CABLE CONNECTION PASSING POINTS CONNECTION HOLES TO THE FLOOR WITH M12 STEEL DOWEL T300 HG120 SINGLE UNIT MATERIAL LIST MI2 STEEL DOWEL MI2SHIM MIONUT MIOSHIM 8PCS 8PCS 8PCS 8PCS Makim Makine Teknolojileri A S All rights reserved Kullanim Kilavuzu m 1 GU UAH EETA Emi 6 2 CARRIAGE INSTRUCTIONS 1 Be careful to carry the hiddengates with the packages prepared by MAKIM Abide by the carriage instructions written on the packages Do not put a heavy material on the package Abide by the stowing instructions Do not put t
13. zu 5 1 T300 HG120 ELECTRONIC CARD Al Sensorl F S Emniyet Sensor F1 Encoder1 YNGA Acil ButonA A2 Sensor2 KNTB Kontrol B F2 Encoder2 YNGB Acil ButonB A4 Sens r3 KNTA Kontrol A M2 Motor2 B1 Sens rl BUZ Ses k 1 Motor1 B2 Sens r2 L1 Led1 24V G Giri i B4 Sens r3 L2 Led2 X Kullanim Disi 5 2 POWER SUPPLY AND SAFETY INSTRUCTION 5 2 1 POWER SUPPLY Control equipment and electronic control unit on the hiddengate are fed with 100W 24V 4 5A single output closed type Power Supply Power supply is capable of feding existing hardware 5 2 2 SUPPLY SAFETY INSTRUCTIONS I Never take off safety cover on the power supply 2 While making any arrangements take into consideration all the warnings on the safety cover and power supply and fuse rating 3 The label on the power supply shows the edges where the connections will be made You should abide by the signs on the label while making connections NOTE DO NEVER FEED EXTERNAL DEVICES FROM THE CONTROL CARD OR POWER SUPPLY OF THE HIDDENGATE MANUFACTURER DOES NOT ACCEPT ANY RESPONSIBILITY FOR THE FAILURES CAUSED BY THIS Makim Makine Teknolojileri A S All rights reserved Kullanim Kilavuzu 6 300 HG120 HIDDENGATE MOUNTING INSTRUCTIONS 6 1 MOUNTING 1 Mounting place should be decided as not to prevent the hiddengate working 2 You should check the smoothness of the floor
Download Pdf Manuals