Home
Optimux-T3 Ring - RADProductsOnline
Contents
1. i Optimux Name opt225 AN Updating Optimux opt225 3 cancel Figure 2 18 Updating Agent Removing an Optimux from the Ring Only Optimuxes that do not exist in other ring application can be removed gt To remove an Optimux from the ring 5 From the Configuration menu select Remove Optimux A confirmation message appears Click lt OK gt Note Ifthe Optimux is currently working in the ring you cannot delete it A warning message Figure 2 19 will indicate so Click lt OK gt i Optimux Name opt227 2 Cannot Remove Optimux opt227 Optimus is currenti working in the Ring Figure 2 19 Cannot Remove Optimux From Ring 2 14 Optimux Management
2. Figure 2 12 Exiting Application 2 Click lt OK gt The application closes Viewing Paths The Path command displays paths between Optimuxes on the ring gt To display paths between Optimuxes on the ring map e From the View menu select Path The existing path between the Optimuxes is displayed on the map Figure 2 13 2 10 System Management RADview HPOV TDM User s Manual Chapter 2 Ring Management 2 ProfrsoRing Contiguration View Options Help lopt227 Figure 2 13 Viewing Paths Displaying Chain View The Chain View command allows you to display sections of the chain link in the ring as invisible gt To make a chain section of the ring map invisible 1 From the View menu select Chain View The Chain View dialog box appears Figure 2 14 I Invisible Connection opt 26 opt 2 i OK Cancel Figure 2 14 Chain View Dialog Box 2 Configure Invisible Connection 3 Click lt OK gt The ring connection between the two Optimuxes becomes invisible on the ring map System Management 2 11 Chapter 2 Ring Management RADview HPOV TDM User s Manual 2 ProfrsoRing configuration View Options Help Opie 2002 06 10 14 56 Ready Figure 2 15 Invisible Chain Connection Setting the Polling Interval gt To set the polling interval 1 From the Options menu select Polling Interval The polling interval dialog box appears Figure 2 16 2
3. Configuration Update Ring Status Configuration gt Kename Configuration Close Configuration Exit Path Fault gt Path Fault Chain View Path Options gt Polling Interval Options Sanity Check Errors The X Connection command displays the X connection table gt To view the X connection table 2 2 System Management The X Connection Table appears Figure 2 2 From the Configuration menu select X Connection Table RADview HPOV TDM User s Manual Chapter 2 Ring Management Note When opening the X connection table for the first time and no path has been added the buttons lt Change Path Name gt and lt Delete Path gt are not enabled 5 optimuxring X Connection Table Sum of Free CHS 26 Path Mame Framer CH Framer Type optar opt 6 Opt225 SE Change Path Name Delete Path Cancel Print Figure 2 2 X Connection Table Changing Path s Name gt To change a path s name in the X connection table 1 Select the desired path in the X Connection Table Figure 2 2 2 Click lt Change Path Name gt The Change Path Name dialog box appears Figure 2 3 System Management 2 3 Chapter 2 Ring Management RADview HPOV TDM User s Manual Change Path Name ES Current Path Mame Path 1 Mew Path Name Path 1 Set Cancel Figure 2 3 Change Path Name 3 Configure New Path Name and click lt Set gt The new path name appears in the X Connection Table
4. Figure 2 2 Deleting Paths from X Connection Table gt To delete a path from the X connection table 1 Select the desired path in the X Connection Table Figure 2 2 2 Click lt Delete Path gt A confirmation dialog box appears Figure 2 4 Ring Name optimuxring 2 Deleting all selected connections Cancel Figure 2 4 Deleting Connections 3 Click lt OK gt The path is deleted from the X Connection Table Figure 2 2 Printing X Connection Table gt To print the X connection table 1 In the X Connection Table Figure 2 2 click lt Print gt The printer dialog box appears 2 Select desired printer and click lt OK gt 2 4 System Management RADview HPOV TDM User s Manual Chapter 2 Ring Management Connecting Optimuxes The Add Delete Path command allows you to connect one Optimux to another gt To Connect one Optimux to another 1 From the Configuration menu select Add Delete Path The Add Delete Path dialog box appears Figure 2 6 Or 2 On the Ring Map Figure 2 1 drag and drop one Optimux to another Optimux The Add Delete Path dialog box appears Figure 2 6 optimuxring Add Delet E Connect Optimus To Optimux Jopt226 Cancel Figure 2 5 Add Delete Path Dialog Box 3 Configure desired parameters and click lt Set gt A window appears with the message Collecting Data A progression bar indicates the status of the process When the proce
5. appears listing all existing rings Optimux T3 Ring x Ring List optimuxring Open Add Remove Close Figure 1 1 Ring List Overview 1 1 Chapter 1 Introduction RADview HPOV TDM User s Manual 2 Select a ring from the list and click lt Open gt A window appears with the message Initializing Ring A progression bar indicates the status of the initialization process When initialization finishes the Ring Map appears Adding a Ring to the Ring List gt To add a ring to the ring list 1 From the Ring List dialog box Figure 1 1 click lt Add gt The Add Ring dialog box appears Figure 1 2 Add Ring x Ring Mame Untitiec Select Qptirnux Selected Optimux IF fo O0 0 0 ET Cancel Figure 1 2 Add Ring 2 Configure the following parameters Ring Name Select Optimux and Select Optimux ID 3 Click lt Set gt The Optimux is added to the ring Removing a Ring from the Ring List gt To remove a ring from the ring list 1 Select a ring in the Ring List dialog box Figure 1 1 and click lt Remove gt A confirmation dialog box appears 2 Click lt OK gt to confirm remove Closing the Ring List gt To close the ring list In the Ring List dialog box Figure 1 1 click lt Close gt The ring list closes 1 2 Overview Chapter 2 Ring Management 2 1 System Management optimuxring Configuration View Options Help Figure 2 1 Ring Map System Mana
6. select Update Ring Configuration A confirmation message appears Ring Name optimuxring AN Updating Ring Configuration Cancel Figure 2 9 Update Ring Configuration 2 8 System Management RADview HPOV TDM User s Manual Chapter 2 Ring Management 2 Click lt OK gt Renaming Ring gt Torename the ring 1 From the Configuration menu select Rename The rename ring dialog box appears Figure 2 10 Rename Ring Es Current Mame fo ptirnuxring Mew Mame loptirnuxring Set Cancel Figure 2 10 Rename Ring Note Ifyou click lt Set gt before configuring a New Name the message Ring name already exists appears with red background in the bottom part of the Rename Ring dialog box 2 Configure New Name 3 Click lt Set gt Closing the Ring gt To close the ring map Figure 2 1 1 From the Configuration menu select Close A confirmation message appears amp x AN Closing optimusring application Back to Optimus Ta Ring Dbox Cancel Figure 2 11 Closing Application 2 Click lt OK gt The ring map closes and the Ring List appears System Management 2 9 Chapter 2 Ring Management RADview HPOV TDM User s Manual Exiting the Application gt To exit the application 1 From the Configuration menu select Close A confirmation message appears Figure 2 12 g x AN Exiting the Optimus Ta Ring Application Cancel
7. RADview PC TDM Network Management System for TDM Applications Optimux T3 Ring 1994 2002 RAD Data Communications Publication 10 02 Contents PRE OCU CUNO BARRE PARC ER ASE ER RNTERnNEEE Een A PRE a 1 1 DE O E A E I T tadetu ener T T ET nee 1 1 Openin RS AO ese ene cece geese N EENE 1 1 King Management esiin iaie ie ie 2 1 PA E E NS 10 A E E E E A E A 2 1 Displaying X COMMECUON Tables de ua 2 2 Solara erg AS e eee E E ee ee tree 20 POS RS SA pe aero easter A E N anne oes 2 8 Updatine Ring CONSO nerne Eae aE eiai 2 8 SC VII RE E E E Rd a 2 9 CRE E O PE E A T 2 9 Se PPI ATO e A E A 2 10 A E A IE A E E A A T N E E 2 10 BE CA E AE 2 11 setine the Poling IMEN al ireen E E E 2 12 Viewine Sanib Check ENON er 2 13 222 OPUMUX Mana SR a ii 2 13 Oy sre ida oye og Qe nr ee ee te ene ee ee ee ee eee 2 14 REMOVING an Optimux from the Ring SR isa taesexe dnseeeion 2 14 RADview PC TDM User s Manual Table of Contents List of Figures RE OR staves 22 CONNCCLON ADI E E E enceesoees 2 Mane Fa Ua ANG save caeavaerer yee teeters 2 Deleting CONSO esseer EE 2 5 Add Delete Path Dialog Box 2 6 Optimux Channel Assignment Dialog Box 2 7 Patan Name Dialog BOX suse de 2 8 Disconnecting All Connections 2 9 Update Ring Configuratio scacecaossuasaxcenecendevayssyaranaseasdetuevacenns 2 10 AIRMAN RIM a E E 2 11 Closing Application ss 2 12 MES ONC ALO Mics RS riar banca dae e Ilos Vi
8. Select a polling interval 60 120 180 or 240 seconds 3 Click lt Set gt lt gt optimuxring Polling Interval E3 Set Cancel Figure 2 16 Polling Interval 2 12 System Management RADview HPOV TDM User s Manual Chapter 2 Ring Management Viewing Sanity Check Errors gt To view sanity check errors e From the Options menu select Sanity Check Errors The sanity check errors dialog box appears Figure 2 17 ProfrsoRing Sanity Check Errors Framer CH Idx Description Optimux Close Fri Figure 2 17 Sanity Check Errors gt To print the sanity check errors 1 Click lt Print gt The printer dialog box appears 2 Select desired printer and click lt OK gt 2 2 Optimux Management Optimux management is performed when an Optimux in the ring is selected Table 2 3 Optimux Management Options System Tasks Dialog Box and Path Configuration Parameter Location Configuration Updating Optimux Updating Agent dialog Configuration Update Agent agent box Update Agent Figure 2 18 Remove Optimux Be Removing See Removing an Configuration Optimux from ring Optimux from the Ring gt Remove Optimux Updating Agent gt To update the agent 3 From the Configuration menu select Update Agent Optimux Management 2 13 Chapter 2 Ring Management RADview HPOV TDM User s Manual The update agent dialog box appears Figure 2 18 4 Click lt OK gt
9. ewing PAR E E E E 2 14 Chain Vew Didog OS a eneesens 2 15 Invisible Chain OAN CIO cteatananeanaaseene 216 Poling TARA er i Eri 2 17 SaNi CHECK ENO 5 ccecten asda eae ceceussancastesaccen see sesesroneyerecenctnte 210 COAST ata E aie E A E 2 19 Cannot Remove Optimux From KIN List of Tables 2 1 Ring Management DEON Sire ee es 2 2 Optimux Channel Assignment Color Coding 2 3 Optimux Management Options ses ss RAR easeaneseaasenutiosans sue ett eacasaensuenes a AOC RS E E N E E RADview PC TDM User s Manual Chapter 1 Introduction 1 1 Overview RADview TDM Network Management System for Optimux T3 Ring provides you with all the necessary tools manage a number of Optimux T3 units connected together in a ring topology The ring topology enables you to connect the Optimux T3 units without the need to connect them through an SDH network The application allows you to connect one channel of an Optimux T3 to another channel of an Optimux T3 in the ring Note You can check management of the Ring from two separated stations that are connected to the same Node However you can t check management of the Ring from two separate stations that are connected to the different nodes on the same Ring Opening the Application gt To open the application 1 From the HPOV map s Misc menu select RADview OV followed by Service Center and Optimux T3 Ring The Optimux T3 Ring Dialog Box Figure 1 1
10. gement 2 1 Chapter 2 Ring Management Configuration Connection Table Add Oelete Path Poll Ring Status Update Ring Configuration Rename Clase Exit Vi Enr Fath Chain views Options Folling Interval Sanity Check Errors Table 2 1 System Tasks Configuration Displaying X connection table Connecting Optimuxes Polling agent Updating ring status Renaming ring Closing ring map Exiting application System Tasks Fault Displaying paths between Optimuxes Making chain sections invisible System Tasks Options Setting polling interval Displaying Sanity Check errors Displaying X Connection Table RADview HPOV TDM User s Manual Ring Management Options Dialog Box and Parameter Location X Connection Table Figure 2 2 Add Delete Path dialog box Figure 2 5 See Polling Ring Status Update Ring Configuration dialog box Figure 2 9 Rename Ring dialog box Rename Ring Close Application dialog box Figure 2 11 Exiting Application dialog box Figure 2 12 Dialog Box and Parameter Location Viewing Paths dialog box Figure 2 13 Chain View dialog box Figure 2 14 Dialog Box and Parameter Location Polling Interval dialog box Figure 2 16 Sanity Check Errors dialog box Figure 2 17 Path Configuration gt X Connection Table Configuration Add Delete Path Configuration Poll Ring Status
11. llow all other cells in the row and column line become blue and the Path Name dialog box appears Path Name Path Mame Path 5 Set Cancel Figure 2 7 Path Name Dialog Box 3 Configure the Path Name and click lt Set gt The Path Name dialog box closes 4 Click lt Close gt in the Channel Assignment dialog box Figure 2 6 System Management 2 7 Chapter 2 Ring Management RADview HPOV TDM User s Manual Disconnecting Connections You can disconnect one connection or all connections gt To disconnect a connection 1 Using the mouse s left button click inside a yellow cell in the Optimux Channel Assignment dialog box Figure 2 6 2 Click lt Disconnect gt The connection is disconnected gt To disconnect all connections 1 Using the mouse s left button click inside a yellow or gray empty cell in the Optimux Channel Assignment dialog box Figure 2 6 2 Click lt Disconnect All gt A confirmation message appears Figure 2 8 Ring optimuxring 2 Disconnecting all Connections between these Optimuxes Cancel Figure 2 8 Disconnecting All Connections 3 Click lt OK gt All connections between the Optimuxes are disconnected Polling Ring Status gt To poll the agent e From the Configuration menu select Poll Ring Status The agent is polled immediately Updating Ring Configuration gt To update the ring configuration 1 From the Configuration menu
12. ss finishes the Optimux Channel Assignment dialog box appears Figure 2 6 System Management 2 5 Chapter 2 Ring Management RADview HPOV TDM User s Manual optimuxring Optimux Channel Assignment Figure 2 6 Optimux Channel Assignment Dialog Box Channel Assignment The Optimux Channel Assignment Dialog Box Figure 2 6 displays the physical channel assignments for the two Optimuxes that were selected in the Add Delete Paths dialog box Figure 2 5 The cells of the table are color coded 2 6 System Management RADview HPOV TDM User s Manual Chapter 2 Ring Management Table 2 2 Optimux Channel Assignment Color Coding Color Remarks Title Cells Bright Green Channel is connected to the opposite Optimux in the table Dark Green Channel is connected to another Optimux not in the table Blue Channel can not be selected E1 group 4 channel Gray Channel is disconnected E1 T1 NA Indicates channel type NA for E1 group 4 channel Inside Cells Yellow Channel is connected to the opposite Optimux in the table Blue Channel can not be selected E1 group 4 channel E1 T1 mismatch connected channel to another Optimux Gray Channel is disconnected Making Connections gt To select a cell 1 Using the mouse s left button click inside a cell in the Optimux Channel Assignment dialog box Figure 2 6 2 Click lt Connect gt Note Connect is available only when there is communication with the agent The cell becomes ye
Download Pdf Manuals
Related Search
Related Contents
user guide mode d`emploi bombes d` artifice et pots a feu du groupe k4 JSSA - 公益社団法人 日本防犯設備協会 SIMATIC IPC227E Krown Dual Alarm Clock with Alerting System User Manual () User Manual Of Intelligent Management System Home Page Copyright © All rights reserved.
Failed to retrieve file