1. SC 500 01 SC 500 02 SC 500 14 SC 500 15 SC 500 06 SC 500 07 Description Monitoring System Control Panel Single Group Control 1 Rack unit high Monitoring Interface 10 way Serial or Infra red eject Group Combiner 10 way same as VS 628 24 Line Drive Power Supply c with Control System cables Audio Monitor c with Power Supply Colour Video Monitor c with Rack Mount Kit 14 inch MACHINE LEADS Video Lead set 10 BNC BNC with Idents 1 10 Audio Lead Stereo set 10 Twin Phono RCA Remote Control Lead set 10 Serial Phono Phono Remote Control Lead set 10 Infra red Phono LED SYSTEM CABLES Video Feed Cable 1 5mtr BNC BNC Video Loop Cable 1 5mtr BNC BNC Audio Feed Cable 1 5mtr Twin Phono Twin Phono Audio Loop Cable 1 5mtr 9 way D Twin Phono Twin Phono Control Feed Cable 1 5mtr 9 way D Control Loop Cable 1 5mtr 9 way D OPERATION 2 1 System Reset Mode When the VS 628 01 is first powered up it automatically goes into System Reset Mode It stays in this mode for about 6 seconds and then goes into normal mode if no buttons are pressed see Configuration Mode below During System Reset Mode the VS 628 01 will display the word ADDR During this time the VS 628 01 will send set up signals to the VS 628 24 units These signals will allow the VS 628 24 units to determine their address number cabinet number 1 to 250 max number of VCRs per VS 628 24 1 to 10 and remote control type It is i
2. button and level button together The display will then show the letter C on the right hand side and a number 1 to 250 on the left hand side The display is now showing the highest cabinet number that the VS 628 01 will monitor 4 1 Maximum Cabinet Setting Procedure 4 shown how to access Configuration Mode for changing the Maximum Cabinet setting to change the setting press Cabinet or Cabinet button The number in the display will change to any value between 1 and 250 To store this new setting in the VS 628 01 non volatile memory press the Auto button for about 1 second The buzzer inside the VS 628 01 will sound and the unit will now go into Normal Mode and automatically select Cabinet 1 level 1 The new Maximum Cabinet setting can be confirmed by pressing Upper Limit and Cabinet buttons together see 2 2 5 while in Normal Mode While in Configuration Mode pressing Lower Limit selects Maximum Level Setting Upper Limit selects Maximum Cabinet Setting Upper and Lower limit together selects VCR type See Warning below regarding storing new settings 4 2 Maximum Level Setting for All Cabinets Enter Configuration Mode as shown in Procedure 4 and now press Lower Limit button The letter L will now be seen on the left hand side of the display and a number between 1 and 10 will be seen under Level This number is the current maximum level setting for all Cabinets To change press Level or buttons To store press Auto butto
3. 628 24 PY PES times teid E a a A ida davai 14 6 VS 628 24 SELF ADDRESSING iereveventaontenoonennnao tonne 15 Ls VCR REMOTE CONTROL TYPES s vesttstii topaev lasvsais devvajapad 16 Pal Rela CCl E ASE T T 16 8 RECORD STATUS MEMORY gis ciccisssesecvedusssosexvedivsatasvoasdariacsedee s 17 9 REAR CONNECTORS ON VS 628 O1 mtenee 19 10 SPEGIFICATIONS rest oss ts alts coveovas eves senta aadeldas Saa konnade 21 1218 SAG 2200 Meh ak ind isik Malai ik 21 10 2 VS 62824 lv aaa jat oniar NE asi 21 1 INTRODUCTION The Copymaster VS 628 series of modules has been designed as an economical approach to the Remote Control and Monitoring in a Video Audio Duplication System In its simplest form it provides Video and Audio monitoring of several Video Cassette Recorders and with the addition of further modules it can provide full Remote Control configured to control one to twenty groups of slave VCRs When the Copymaster 628 Series is arranged as a simple monitoring system the main components are the Monitoring Control Panel VS 628 01 and a number of Monitoring Interface units VS 628 24 each of which can be connected to 10 VCRS Additional Monitoring Interfaces can easily be added for system expansion In fact any system from 10 to 2500 VCRs can be accommodated The Monitoring Control Panel is user friendly with simple to use push buttons and six segment LEDs to display the selected VCR position Step up Step down
4. 628 monitoring system is added on to an existing or new Video Duplicator which has some VCRs stacked 8 high or 10 high or even 15 high It is possible to programme the non volatile memory inside the VS 628 01 so that the up down counter for cabinet skips unconnected inputs level on the VS 628 24 interfaces For example if some VCRs are stacked 8 high then the VS 628 24 interfaces which connect to these VCRs would have only inputs 1 to 8 wired and in the case where the VCRs are stacked 15 high two VS 628 24 interfaces could be used One would have inputs 1 to 10 wired and the other would have inputs 1 to 5 wired or any other combination which adds up to 15 Of course two successive cabinet numbers displayed on the VS 628 01 would refer to one stack of 15 VCRS To set maximun level setting for individual cabinets make sure that Pole 2 and Pole 1 of the 8 pole switch inside the VS 628 01 is switched to ON position Next power up the VS 628 01 unit and while the word ADDR appears hold down Cabinet button and Level button together The display will then show C on the right hand side and a number on the left hand side Now press Lower Limit button The letter L will now be seen in the centre of the display with a 1 under Cabinet for Cabinet 1 and a number under Level which represents the current Maximum Level for cabinet presently indicated in this case Cabinet 1 11 The Maximum Level for any cabinet between 1 and the current Maxim
5. Set Upper and Lower Limits Auto Cycle On Off and individual Eject of current selected VCR are some of the powerful features offered A non volatile memory within the Monitoring Control Panel allows system variables to be entered such as maximum number of interfaces number of VCRs per interface for situations where VCRs are not stacked 10 high and Remote Control type for each interface Infra red Remote Control or Serial Remote Control The above Monitoring System can be transformed into a full Video Duplication System by the addition of the Remote Control Panel VS 628 02 Group Control Panel VS 628 04 05 and necessary Video and Audio Routing Switchers and Distribution Amplifiers see the 10x10 Video Audio Matrix Switcher VP 738 and 1x10 Video and Audio Distribution Amplifier VP 702 This collection of modules is called the COPYMASTER 2500 System The VS 628 02 provides Remote Control function Play Stop Rewind Fast Forward Pause Eject and Record A button labelled QC VCR controls whether the Remote Control commands are sent to the selected VCR or all VCRS A lock button is also provided The VS 628 03 has 10 buttons with integral LEDs for group selection of slave VCRS The VS 628 05 provides selection of slave VCRS The VS 628 05 provides selection of a further 10 groups These panels are used in two ways One is to control which groups of slave VCRs that are to respond to Remote Control commands from the VS 628 02 panel Further powerf
6. special control word to each of the VS 628 24 interfaces This control word sets up the VCR remote control type for the EJECT function The non volatile memory can be programmed to store Remote Control VCR Type for each of the VS 628 24 interfaces in the system For information on different VCR types see Sections 4 2 and 7 To set VCR type for Individual cabinets make sure that Pole 3 and Pole 1 of the 8 Pole switch inside the VS 628 01 is switched to ON position Note Pole 2 can be in ON or OFF position Now power up and enter the configuration mode and then press both Upper Limit and Lower Limit buttons together The display will now show the letter t in the centre of the display On the left hand side of the letter t is the number 1 for Cabinet 1 interface 1 On the right hand side of the letter t is a number 0 to 28 indicating the current VCR type for the Cabinet being shown 12 By using the Cabinet and buttons and the Level for VCR type and buttons and the OC EJECT button for entering new values into the non volatile memory the VS 628 01 can be programmed in a similar manner as described in 4 4 for Maximum Level setting for individual cabinets Press AUTO ON OFF to return to Normal Mode 4 6 Assigning Cabinets to a Group Number This can be done if the Group Control Panel VS 628 03 is connected to Port 1 or Port 2 of the VS 628 01 While in Configuration Mode press Upper Limit and Cabinet button together and the lett
7. 232 loop in Infra red diode or Serial Phono Relay Eject open collector Phono 9 way D socket parallel control for connection to VS 608 03 9 way D socket Pseudo RS232 4800 Baud 9 way D socket Pseudo RS232 4800 Baud lu 1 75 inches high 19 inch rack mount 6 inches deep 2 6 Kg DWIGHT CAVENDISH DEVELOPMENTS LIMITED Vincent House Alington Road Eynesbury Cambridgeshire PE19 4YH England Telephone 01480 215753 Fax 01480 474525 Telex 32744 DWICAV G 22
8. 28 01 non volatile memory Comments Eject usually works IR Eject only works on new Models IR Eject only works on new Models IR Eject usually works IR Eject usually works IR Eject usually works IR Eject usually works IR Eject usually works IR Eject usually works IR Some have EJECT IR AG6840 50 AG 5250 SV0960 Control P Eject usually works IR Eject may not work on older models IR Eject usually works IR Some have Eject IR Some have Eject IR Eject usually works IR Eject usually works IR BR7000 BR7020 30 40 No Eject IR Eject usually works IR Double stop causes Eject IR Some have Eject Eject usually works IR Type 1 Type 2 Type 3 SVO140 170 9620 1410 1610 1500 Setting VCR Type 0 JVC 1 Panasonic Old 2 Panasonic New 3 Sony Betamax USA 4 Sony Betamax Europe 5 Sony VHS 6 Mitsubishi 7 Sharp 8 Philips Grundig 9 Thompson 10 Panasonic Serial 11 Sony Serial 12 NEC 13 Sanyo 14 Hitachi 15 Toshiba 16 17 Akai 18 Sony Video 8 19 Goldstar 20 JVC Serial 21 Ferguson 22 Awia 23 Samsung 24 Thomson Saba 25 Sony Control S 26 Sony Control S 27 Sony Control S 28 29 IR Infra red type remote control 7 1 Relay Eject For VCRs which do not have Infra red eject it is possible to add a Relay Eject Assembly inside the VCR with 2 wires soldered across the VCRs eject button This assembly is connected to the VS 628 24 relay eject outputs 16 8
9. CRs by infrared remote control 2 2 7 Auto Cycle Mode Press the Auto button for about half a second to select Auto Cycle Mode The LED on the Auto button will light up at the moment when the finger is released from the button The level position will now automatically increment and when the maximum level is reached usually 10 the cabinet number will increment Upper and Lower limits can be used to determine roll over points If the QC Eject button is pressed the Auto Cycle mode will temporarily stop while the Eject signal is sent to the VCR 3 SET DWELL TIME MODE This mode is selected by holding down the Auto button for about 3 seconds while in the normal mode The display will indicate Dwell Time mode by showing the word AUTO followed by a number in the level position This number is the current Dwell Time in seconds The Dwell Time is the time spent in each cabinet level selected position while in Auto Cycle Mode The level and button can be used to select one of twenty different Dwell Times ranging from 0 3 seconds to 20 seconds On power up the Dwell Time defaults to 1 2 seconds To return from set Dwell Time Mode to Normal Mode press Auto button for about 1 second 4 CONFIGURATION MODE To enter Configuration Mode pole 1 of the 8 pole switch inside the VS 628 01 must be switched to ON position Next the VS 628 01 is put into System Reset Mode see 2 1 and while the word ADDR appears on the display hold down Cabinet
10. DWIGHT CAVENDISH VS 628 01 MONITORING CONTROL PANEL USER HANDBOOK INCLUDING ADDITIONAL MODULE VS 628 24 10 WAY INTERFACE INDEX Number 1 INTRODUCTION tia siia ea AARE eaa dou iene TASASE AS an 3 Meh Inter connections sahti aaa ka asd A alea UT ad ets 4 1 2 QC Monitoring System Components 5 2 OPERATION ce cstiscacnecaentieswescented naidata e kaela al 6 21 System Reset Modenasse 6 2241 Level Selections pe sia deat eal lag aagieeava cay ach tagaaeda 6 2 22 Cabiiiet Selection iiis 0c 4 sc uoead detiedisaitee iced dade vajuda kala Gee 7 22 Upper Eimi teinn E aE A E ASR 7 2 24 lt Lower LAMM bs sieisen eia a toatl eae 7 2 2 5 Go to Upper and Go to Lower Limit eeree 7 220 QCH Ecion an aa a a TE ATEEN 7 Zend Auto Cycle Mod necie a e a eens 8 3 SET DWELL TIME MODE otsis t kitsai kikkis ikk ku 9 4 CONFIGURATION MODE essesnesseseseesseseresssssressssssrresssseeessssse 10 4 1 Maximum Cabinet SEIM utsalisv mlaat eakaaslased ara adas 10 4 2 Maximum Level Setting for All Cabinets meeeereeeoenneeoenee 10 4 3 VER Type for All Cabimets 14 reas ekad kisa kuida k sate Ma kuivatid k nka ke Tekk 11 4 4 Maximum Level Setting for Individual Cabinets imeene 11 4 5 VCR Type for Individual Cabinets 200 0 eeecceeeeeceeeseeeeceeeeeesteeeenaeeeenes 12 4 6 Assigning Cabinets to a Group Numbet mrerneoenneeenue 13 De VS
11. RECORD STATUS MEMORY When the Group Control Panel VS 628 03 is connected to the System Control Panel VS 628 01 itis possible for the VS 628 01 panel to store Record Status of the VCRs in each group This Record Status can be displayed for a few seconds on the LEDs 1 to 10 of the Group Control Panel VS 628 03 also LEDs 11 to 20 on the VS 628 05 To access the Record Status Memory press both Level and buttons together The display on the VS 628 01 will show the word REC followed by a number 0 to 15 If the number displayed is 0 then there are no groups which have VCRs in record mode The Group Control Panel will at the same time show none of its LEDs lit up The word REC 0 will be seen for 2 seconds and the display will then return to Normal Mode and indicate Cabinet and Level selection Also the Group Control Panel VS628 03 and VS 628 05 will return to its normal mode of displaying the present group selections If the number displayed is above 0 ie 1 to 15 then the Group Control Panel will indicate which groups are in Record Mode The number displayed against the word REC is the record session number There may be more than one record session on the go at any point in time To access the other record sessions press Cabinet button repeatedly The buzzer will beep when all the record sessions have been displayed The groups which are in Record Mode will be indicated on the VS 628 03 panel for each record session It is possible to ret
12. S 615 01 which would act as a master Remote Control Panel to several VS 628 01 systems External parallel input 9 Pin D Type Plug Pin Function Rewind Stop Play Record gt To activate command connect to 5v Pause l Eject Fast Forward 5V Ov Ooovaoovu oOoINnnr 20 10 SPECIFICATIONS 10 1 VS 628 01 Cabinet Address Range VCR Level Address Range Max Number of VCRs in System Dwell Time in Auto Mode Power Consumption Input Voltage Dimensions Weight 10 2 VS 628 24 Video Input 10 Video Output 1 Video Freguency Response Stereo Audio Input 10 Stereo Audio Output 1 Maximun Audio Input Level Maximum Audio Output Level Audio Gain Adjustment Nominal Audio Level Headroom Audio Crosstalk 2500 0 3 to 20 seconds 25 W max 90 130 180 260 v switchable 50 60 Hz lu 1 75 inches high 19 inch rack mount 6 inches deep 3 1 Kg 1 v p p 75 ohm BNC 1 v p p 75 ohm BNC 5 dB 6 MHz Impedence 20 Kohm Phono unbalanced Impedence 560 ohm Phono unbalanced 22 dBu 12 dBu 8 dB to 12 dB 6 GB in 6 dB out 18 dB 90 dB at 1 KHz input to input 21 Audio S N Audio Freguency Response DC Power Remote Control Outputs 10 Aux Output RS232 Loop In RS232 Loop Out Dimensions Weight 76 dB ref 6 dBu 1 dB 20 KHz 8 v 130 mA selected 44 mA unselected RS232 loop in 8 v 86 mA selected 10 mA unselected RS
13. d Group Control Modules VS 628 03 05 1 1 Inter connections The system monitor panel VS 628 01 is the control panel for monitoring Video and Stereo Audio playback from a number of VCRS It also provides individual remote control eject signal to the VCRS The VS 628 01 is connected to a number of 10 way monitor interface units VS 628 24 The minimum number of VS 628 24 is 1 and the maximum number is 250 This allows monitoring of up to 2500 VCRS Connection is made between the VS 628 01 and VS 628 24 units via a 9 way cable which carries serial data RS232 format and dc power supply The VS 628 24 contains a 10x1 video and stereo audio switcher There is also 10 outputs for remote control infra red or JVC serial There are also another 10 outputs which are open collector pull to ground logic for connection to eject line on parallel 4 multi wire type remote control The VS 628 24 has loop through output on Video and Audio for easy daisy chain connection The VS 628 01 can provide power for the first 10 VS 628 24 units The VS 628 01 has a non volatile memory and during the installation of the system it is configured to store system constants such as maximum number of VS 628 24 units number of VCRs per VS 628 24 unit and remote control type JVC or Panasonic infra red etc 1 2 OC Monitoring System Components Module Number VS 628 01 VS 628 24 VS 628 06 VS 628 07 VS 628 09 MC 608 01 MC 608 02 MC 608 24 MC 608 26
14. er F will appear in the centre of the display In a similar manner to above the Cabinet and buttons and the Level for Group Number and buttons and the OC EJECT button for entering New Values can be used to carry out the assigmnents See 4 0 in the Control Group User Manual for further details 13 5 VS 628 24 TYPES Inside the VS 628 24 is a 2 pole 2 position switch The settings of this switch determines 1 of 4 possible types as shown in the table below VS 628 24 2 POLE SWITCH Type Pole 1 Pole 2 Comments 0 OFF OFF Standard 1 OFF ON Combiner Remote Control not used 2 ON OFF Follower Remote Control not normally used 3 ON ON Combiner Follower Remote Control not used The standard type of VS 628 24 can be converted into any of the other three types by changing the 2 pole switch position The standard Type 0 provides switching of Video and Stereo Audio from 10 VCRS It also provides the remote control Eject function to these VCRS The Follower Type 2 provides switching of a second video eg Y and C of an S Video signal and a second Stereo Audio eg Hi Fi Audio with the standard unit switching Linear Audio The Follower unit will have the same cabinet address as one of the standard types The Combiner Type 1 provides Video and Stereo Audio switching from groups of standard units Each input of the Combiner unit connects to daisy chained video and audio signals from 5 standard units Hence a Combiner un
15. it will select one Video and Stereo Audio signal from 500 VCRS When used in this manner it is given the number VS 628 06 The Combiner Follower Type 3 switches the Video and Stereo Audio from Follower Type 2 units 14 6 VS 628 24 SELF ADDRESSING When the system is powered up and the VS 628 01 goes into System Reset Mode see 2 1 all of the VS 628 24 units will determine their own Cabinet address number This is done by each VS 628 24 unit sending an address signal its own address 1 to the next unit which is connected via the 9 way looping cable The first standard unit the one which is connected to VS 628 01 will become Cabinet address 1 the next one of the same type see type 0 1 2 3in 5 above will become Cabinet address 2 The first Combiner unit the one nearest to the VS 628 01 will become Combiner unit 1 and the next Combiner unit 2 The Combiner unit can be connected anywhere along the chain of Standard units and will not affect the addressing order of the standard units The whole of the self address seguence will only take 2 to 3 seconds The address of any standard unit can be checked against the cabinet number displayed on the front of the VS 628 01 by checking that the LED indication on the standard VS 628 01 is lit up only one standard type in the whole system will be lit up 15 7 VCR REMOTE CONTROL TYPES See 4 2 and 4 3 for details of how to enter the VCR Remote Control type into the VS 6
16. l roll over to cabinet number 1 It is also possible to roll under from cabinet 1 to maximum cabinet number as set during configuration mode or by upper limit button 2 2 3 Upper Limit A temporary upper limit for cabinet address on the VS 628 01 can be set by holding down the upper limit button for about half a second Upper limit selection is indicated by a single horizontal bar Upper position on the centre seven segment display To cancel press Upper and Lower limit buttons together for about one second 2 2 4 Lower Limit A temporary upper limit for cabinet address on the VS 628 01 can be set in the same manner as above A lower horizontal bar will now be seen on the display It is possible to have a temporary upper and lower at the same time Again cancel by pressing both the Upper and Lower buttons together 2 2 5 Goto Upper and Go to Lower Limit It is possible to go directly to the Cabinet Upper Limit address by holding down Upper Limit button and Cabinet button together It is also possible to go directly to the Cabinet Lower limit address by holding down Lower Limit button and Cabinet button together In both of these cases level one is selected 2 2 6 QC Eject When this button is pressed the current addressed VCR cabinet and level is given an Eject signal by the remote control output on the VS628 24 unit The word EJECT will be seen on the VS 628 01 display Note It may not be possible to eject certain makes of V
17. mportant that the VS 628 01 is powered up at the same time or at a time which is later than when the VS 628 24 units are powered up If this does not occur the VS 628 24 unit will not operate properly The System Reset Mode can also be selected during normal mode by holding down cabinet level and Auto button together for about half a second The display will blank and then the word ADDR will be seen for about 6 seconds in the same manner as above After this the display will show Cabinet 1 level 1 Normal mode 2 2 Normal Mode In normal mode the VS 628 01 will send signals to the VS 628 2224 units to select one video and audio signal from the many video and audio signals which are connected to the VS 628 24 units If the VCRs are of suitable remote control type the VS 628 01 can send an eject signal to the VCR which is currently displayed Cabinet number and level number 2 2 1 Level Selection The Level and buttons will allow selection of the VCR level inputs 1 to 10 of the VS 628 24 unit Automatic increment and decrement of cabinet number takes place as the level rolls over the maximum level or rolls under level one 2 2 2 Cabinet Selection The cabinet and buttons will allow selection of the cabinet number VS 628 24 unit The buttons can be stepped or held down If held down the increment or decrement rate will speed up to a maximum of 3 cabinet addresses per second When the maximum cabinet is reached it wil
18. n for about 1 second the display will now return to Normal Mode WARNING When the Auto button is pressed in the configuration Mode the values for Maximum Cabinet setting Maximum level setting and VCR type are stored in the non volatile memory It is important that all three settings are correct before pressing the Auto button 10 4 3 VCR Type for All Cabinets Enter Configuration Mode and then press both Upper Limit and Lower Limit buttons together The display will now show the letter t on the left hand side and a number 0 to 29 on the right hand side The number 0 to 29 describes the VCR type for remote control not all of these numbers are designated some are for future use See the table VCR type at the end of this User Manual for current assigned types In general the values 0 to 9 and 12 to 28 are different infra red types JVC 0 Panasonic 1 etc The value 10 is JVC Serial and 11 is Sony Serial as used on the Industrial VHS VCRs BR7000 AG6850 SVO960 WARNING Do not select positions 10 11 or 20 by pressing Auto button if the VS 628 24 monitor interface units have Infra red LEDs connected to the remote control output The serial logic level has opposite polarity to the infra red logic level and this could result in excessive current taken from the power supply Note Not all the infra red types are capable of eject signals 4 4 Maximum Level Setting for Individual Cabinets There may be situations where the VS
19. nit are the following connectors a b c d Phono labelled hold input Connecting the centre pin to ground will cause the auto cycling to stop stepping Opening this connection will allow the cycling to continue This feature allows the possibility of a loss of video detection to stop the cycling for further inspection of the video signal Phono labelled inhibit output Whenever a remote control button is pressed QC Eject on VS 628 01 or Functions on the Remote Control Panel VS 628 02 a logic high 5v occurs on this connector This signal is fed to Panel VS618 01 to inhibit its generation of secondary remote control signals 9 way D type socket labelled Output to VS 628 24 A cable from this output connects to and loops through all the interface modules VS 628 04 which are in the system It carries communication signals and power supply lines 9 way D type socket labelled Port 1 and Port 2 These connect to a range of other panels which compliment the Monitoring Control Panel Typical examples are Remote Control Panel VS 628 02 Group Control Panel 1 10 VS 628 03 QC Control Panel VS 628 04 Group Control Panel 11 20 VS 628 05 Secondary Functions Panel VS 628 08 19 e 9 way D type plug labelled Port 3 This connector is a parallel remote control input Input signals are Play Stop Rewind FF Pause and Eject This input would be fed from one of the five group outputs of the Remote Control Panel 5 Group V
20. ul features are e Flexible addressing seguence Each Interface Module can be connected to any number of VCRs 1 10 and the VS 628 01 Panel can be programmed to only address the VCRs which are connected unconnected VCRs are skipped e Different Remote Control types can be accommodated Each Interface Module can be pre set to be Infra red or Serial Remote Control Manufacturers include JVC Sony Panasonic Sharp etc Parallel Remote Control is available by the addition of VS 60803 10 way Remote Interface module to any of the existing VS 628 24 Interface Modules e Up to 20 Remote Control Groups Each Interface Module is assigned to a group e Interface Modules can be configured to act as a follower to existing Interface Modules so that 2 Video Channels ie Y C or Video and RF off tape and 4 audio 2 Linear and 2 Hi Fi can be switched e Variable dwell time for automatic stepping of VCR address 0 3 to 20 seconds in 20 steps Push button selection on VS 628 01 Panel e In most cases the system can be overlaid onto existing Video Duplicators which require monitoring this also gives individual eject e Ten Relay Eject Outputs provided on each Interface module This is to drive a relay inserted in VCR This relay connects to the eject button for individual or Master Eject Alternatively this output can be patched into an existing parallel Remote Control System Separate User Handbooks are available for Remote Control Module VS 628 02 an
21. um Cabinet see 4 1 for setting of Maximum Cabinet can be examined by pressing the Cabinet and buttons If a change is required to Maximum Level for any individual Cabinet then select that Cabinet using the Cabinet and button as above and then select the New Maximum Level by pressing the Level or buttons To enter this new value into the non volatile memory press the OC EJECT button The display will be seen to flash off for a fraction of a second The buzzer will also give a sound Note In the Maximum Level setting for each cabinet the Maximum Level settings are 1 to 10 O indicates that the whole cabinet all ten levels will be skipped while stepping up and down in Normal Mode For situations where there are several consecutively numbered Cabinets which have the same Maximum Level setting there is a quick method of programming the non volatile memory First select the lowest numbered Cabinet of the group to be programmed with the same levels Then select the New Maximum Level setting for that group Now hold down the QC EJECT button and a moment later also hold down the CABINET button The VS 628 01 will now automatically enter the New Maximum Level setting and at the same time increment the Cabinet setting When the highest Cabinet number is reached release the EJECT and CABINET buttons To enter Normal Mode hold down the AUTO ON OFF button 4 5 VCR Type for Individual Cabinets During power up the VS 628 01 sends a
22. urn to Normal Mode by pressing the Level and Level buttons together or by not pressing any buttons for 10 seconds The VS 628 01 can store up to 10 record sessions these record sessions are labelled 1 to 15 A record session is cancelled from the VS 628 01 memory when all the groups which are presently in Record Mode are given a stop signal When all the record sessions are cancelled the VS 628 01 display will display REC 0 Each new record session which is created is given the next available record session number the next number after 15 is 1 It is assumed that the original record session 1 would have been cancelled by this time otherwise there will be two record session in memory When displaying record sessions the LED pattern of the groups in Record Mode can be transferred to Normal Mode by pressing the Auto button When in Normal Mode this same pattern of LEDs will indicate groups selected This feature is useful in that it saves the Operator writing down on paper the pattern of LEDs for a particular record session and then having to re select this pattern when in normal mode 17 It should be noted that the record sessions only provide a memory of which groups are presently in record mode This is pseudo status and not actual status It is possible for the VCRs to be in a different mode to that indicated for example the VCRs may be stopped due to the tape ending 18 9 REAR CONNECTORS ON VS 628 01 On the rear of the u