1.      Figure 1   Warnings    e Only connect an AR 1 module to an approved Ring Engineering Power  Supply    e Never connect a Ring Engineering AR 1 to a DCC power supply  Our AR 1  is only designed to work with Ring Engineering RailPro products    e Be sure to perform the    Coin Test as describe in this manual    e There are no user serviceable parts inside  Return to Ring Engineering for  repair    e This product contains a chemical known to the state of California to cause  cancer and birth defects  or other reproductive harm   This product contains  lead     Ring Engineering Inc 2    BRING RailPro    ENGINEERING       Installation  Step 1   Mount your AR 1    Position the AR 1 under your layout near the reversing section of track that you  plan to wire to the AR 1  Use at least 2 screws and mount the AR 1  If only  using two screws  be sure the screws are located in opposite corners  The red  arrows in figure 1 below identify mounting hole locations     RailPro    Auto Reverse Module  Model   AR 1       Figure 1   Step 2     Connect the Wires    Be sure the power supply you are going to connect to the AR 1 is turned off   Then connect the power supply to the    To Power Supply    terminals labeled    PS1     and    PS2    with 16 gauge wire  Then connect the    RT1 and    RT2    terminals to the  reversing section of track     Wire Gauge   Power 16 AWG  Supply indi  dy Feet  Black Red  an    BEE  PS1           Wire Gauge  16  AWG   sa 10 Feet   ax               RailPro  Au
2. RING    ENGINEERING    Model Railroad  Auto Reverse Module  AR 1     User Manual    Ring Engineering Inc    219  322 0279  www RingEngineering com Revision 1 00    Copyright    2012 Ring Engineering Inc  All rights reserved     BEING RailPro    Introduction       Thank you for purchasing this Ring Engineering product  We take pride in the  products that we produce and hope you find this product to be a great addition to  your model railroad layout     Please read all warnings and instructions before installation and use  For the  latest information including the latest revision of this manual please visit our  Internet site at www  RingEngineering com     The AR 1 is used to power special configurations of track such as in figure 1   These configurations of track would cause a short circuit if connected without the  use of an AR 1  Note that in each configuration if you follow Rail  A  around you  will notice that it connects to Rail    B     That is just like putting a piece of metal  across Rail    A    and Rail  B which would cause a short circuit and in turn would  cause a power supply to shut down  The solution to power special track  configurations like below is to add insulation gaps and power the sections with an  AR 1  The AR 1 can also be used to isolate small sections of track  limiting the  impact of short circuits if derailments occur to just one area of your layout     uie Reversing Loop rara Reversing  Y  Turn Table  Rail  B  Rail  B   Rail    A    a  Rall  B  
3. ce this product  or any component of the product found to be defective during the warranty  period  Replacement will be made with new or remanufactured product or  component  If the product is no longer available  replacement may be made with  a similar product of equal or greater value  This is your exclusive warranty     This warranty is valid for the original retail purchaser from the date of initial retail  purchase and is not transferable  Ring Engineering dealers  distributors  or retail  stores selling Ring Engineering products do not have the right to alter  modify  or  any way change the terms and conditions of this warranty     The warranty does not cover normal wear of parts or damage resulting from  negligent misuse of the product  Further  the warranty does not cover Acts of  God  such as fire  flood  hurricanes  and tornadoes     Ring Engineering shall not be liable for any incidental or consequential damages  caused by the breach of any express or implied warranty or condition  Except to  the extent prohibited by applicable law  any implied warranty of merchantability or  fitness for a particular purpose is limited in duration to the duration of the above  warranty  Ring Engineering disclaims all other warranties or conditions  express  or implied statutory or otherwise  Some states or jurisdictions do not allow the  exclusion or limitation of incidental or consequential damages or limitation on  how long an implied warranty lasts  so the above limitation or ex
4. clusion may not  apply to you  This warranty gives you specific legal rights  and you may also  have other rights that vary from state to state     To obtain warranty service contact Ring Engineering at     Email  info ringengineering com  or Phone  219  322 0279    to get a return authorization and return instructions   If your Ring Engineering product is not covered by warranty  or has been    damaged  an estimate of repair costs or replacement costs will be provided to  you for approval prior to servicing or replacement     Ring Engineering Inc 6    
5. e quarter test to  every section  at least every 3 feet  of track until each section is tested and  passes this test        Since the track is exposed and can easily be shorted by things like a derailed  locomotive  your AR 1 has built in short circuit protection with auto recovery   When a metal object gets across the track rails  the AR 1 outputs are connected  together and you create a short circuit  The AR 1 will automatically detect the  short circuit  turn off the output  and the power indicator light will turn red  If the  Output Is off  all trains in the reversing section will stop because they will no  longer have power  The power indicator light will stay red until the short is  removed  After a few seconds from the short being removed  the AR 1 will  automatically turn the power to the track back on     Your AR 1 is now ready to use     Operation    There is only one thing to be aware of while operating your AR 1  You should be  sure that both isolation gaps are not crossed by two locomotives at the same  time  In a locomotive  usually the wheels are wired together inside so when a  locomotive is across the gap  one set of wheels are contacting the track on one  side of the gap and the other set of wheels are contacting the track on the other  side of the gap  This means that when a locomotive drives over a gap the rails  on both sides of the gap are connected together by the locomotive  And this is  ok if one gap at a time has a locomotive over it  But if two loco
6. e wire a tug to be sure it is securely connected           Figure 3     Step 3     Do the Coin Test before using your AR 1    This step is important  This step is important because your AR 1 needs to be  able to shut off when the track is shorted  This test will confirm if your track is  wired well enough so the AR 1 will be able to detect the short and turn off  If the  track is shorted and the connection of the AR 1 to the track is poor  the short will  not draw enough power from the AR 1 to detect the short  and the AR 1 will not  turn off  delivering power to the track   s bad connection  Although it is very  unlikely  it is conceivable that a bad connection could heat up enough to ignite  flammable material near the bad connection  This precaution would be the same  for any model railroad power supply with the same amount of power whether it  was RailPro  DCC  or Analog     Use a quarter and place it across the rails of your track as shown in figure 4 and  be sure the AR 1 power indicator light turns red          Spl ar  Figure 4     Coin Test    A red light indicates that the short was detected and the power to the track was  turned off  If the light does not turn red when the quarter is positioned on the    Ring Engineering Inc 4    BRING RailPro    track  then the wiring to that section of track needs to be improved  You may  need to improve the connections to that section of track  or use thicker gauge  wire to feed that section of track  Go along the track and do th
7. motives are across  both gaps at the same time  then that will create a short circuit from Rail  A  to  Rail    B    and the power supply connected to the AR 1 will shut down  Also keep in  mind that most products that use electricity from the track such as lighted  passenger cars  our End of Train Devices  etc   have the wheels wired together  and can cause the same problem as a locomotive if across both gaps at the  same time  In other words if a locomotive is across one gap  and at the same  time a lighted passenger car is across the other gap  the power supply will shut  down causing the train to stop running     Indicator Light Status    Indicator Color   Status oO o  Flashing Green Powering Up    Output ON in the Forward Direction  Normal Operation     Output ON in the Reverse Direction  Normal Operation     Solid Red Output shorted  Automatically recovers when short removed   Red Flashing 4 times   Power Supply Input is Under Voltage  Cycle Power to Reset     Red Flashing 6 times   Over Temperature  likely cause  ambient temperature is too hot    Cycle Power to Reset     Red Flashing 8 times   Power Supply Input is Over Voltage  Cycle Power to Reset        Ring Engineering Inc 5    BEING RailPro    Warranty       Limited One Year Warranty    Ring Engineering  Inc   Ring Engineering  warrants that for a period of one year  from the date of purchase  this product will be free from defects in material and  workmanship  Ring Engineering  at its option  will repair or repla
8. to Reverse Module  Model   AR 1    Feeder Wires  Gauge 22 24 AWG  Length  4 Inches Max        Double             Insulated  Gap N  Rail  A   Rail  B     Note  Use  ire f Double  ote  Use larger wire for  longer than 10 foot runs         Figure 2     AN Only connect a Ring Engineering approved power supply to the  proper power input connections such as the PWR 75  Maximum voltage is  16 Volts DC  Never connect a DCC power supply to the AR 1     If the power supply you are using is capable of auto reversing  be  sure the power supply is set to    Auto Reverse DISABLED        A NOTE  The AR 1 IS polarity sensitive  You must connect the power  supply positive  red  to the positive input on the AR 1  PS2  and the power  supply negative  black  to the negative input on the AR 1  PS1     3    Ring Engineering Inc    BEING RailPro    The AR 1 is equipped with spring loaded terminals for fast and secure  connections that do not require a tool  To connect a wire to the terminals  first  strip 3 8 of an inch  about 2 3 the length of the terminal block  of insulation off of  the wire  Then press the orange push button over the contact that you want to  connect a wire to  Insert the wire into the round hole under the orange push  button  Be sure the wire goes all the way to the back of the terminal block while  holding down on the orange push button  When you feel the wire touch the back  of the terminal block  release the orange button to secure the wire into the  terminal block  Give th
    