Home

User manual - Security Accessories, Access/Entry

image

Contents

1. We recommend immediate update and recording of your Master Code Programming Step Keystroke Combination 1 Enter Program Mode Master Code 2 Update Master Code O New Master Code Repeat New Master Code SET ACCESS CONFI GURATION There are 3 types of access configurations for the K401 e Card or PIN Default The User must present a valid Card to the K401 I or enter their PIN code followed by the key in order to be granted access e Card Only The User must present a valid Card to the K401 I in order to be granted access e Card PIN The User must first present a valid Card to the K401 I and then enter their PIN code followed by the key in order to be granted access Programming Step Keystroke Combination 1 Enter Program Mode Master Code 2 Card or PIN 30 Default 3 Card PIN 317 4 Card only 32 Set Relay Configuration The relay configuration sets the behaviour of the output relay on activation Programming Step Keystroke Combination 1 Enter Program Mode Master Code 2 Pulse Mode 4 1 99 The relay time Is 1 99 seconds 1 is 50ms Default is 5 seconds 3 Latch Mode 40 Sets the relay to ON OFF Latch mode 4 Exit program mode Set Strike out Alarm The strike our alarm will engage after 5 failed card PIN attempts Factory default is OFF The strike our alarm can be set to deny access for 10 minutes after engaging or it can be set disengage only after entering a valid car
2. 1D Deleting by ID number will clear cards and PINS Programming Step Keystroke Combination 1 Enter Program Mode Master Code Others Reset to Factory Default This will reset the K401 I to factory default but all card PIN information will still be retained 1 Power the K401 1 down 2 Press and hold the button and power up the K401 I 3 There will be two bleeps Then release the button after a second there will be one more bleep to confirm reset Erase all Cards This will delete ALL User data 1 Enter Program Mode Master Code 2 Press 20000 3 Exit All configuration data Is retained Reset Strike Out Alarm Enter Master Code or Valid Card PIN to silence Sound and Light indication Operation Status Rede creen LED souns Poweron Sening O O Cotsen sany Seni S O CPress Keypad Fishing O OO rosne meen Erter master code Emay Mode Jon rotshgeseen rin programmo on Sngeran short singe Beep Entered Program Step Successfuly ON Sinole Flash shor Single Bleep 7 ee oo Exit from the programming mode Flashing Entry Granted ON Open lock Green light bright OneBleep a a Short Single Bleep Alarm Mode Engaged Flashing Red light Shines quickly Pressing Toggles Standby Master ON Flashing Code Entry K401 1 Simplified I nstruction Enter the Programming Mode Master Code 6666 Is the default factory master code Change the Master Code O New Master Code Re
3. KP 401 A Internal Stand Alone Keypad Proximity Ready User Manual INTRODUCTION The K401 1 is a single relay multifunction standalone access control keypad suitable for indoor use It is housed in a strong sturdy and vandal resistant Zinc Alloy electroplated case It supports up to 1000 users in a Card PIN or a Card PIN option The inbuilt card reader supports 125KHZ EM frequency card or key fob and the Pin length Is 4 6 digits The single relay can operate in Pulse Mode suitable for access control or Toggle Mode suitable for arming disarming alarms switching lights machines etc The K401 I has many extra features including block enrollment anti tamper alarm amp backlit keypad buttons These features make the K401 I an ideal choice for door access not only for small shops and domestic households but also for commercial and industrial applications such as factories warehouses laboratories banks and prisons Features Vandal resistant enclosure Backlit Keypad buttons Multi color LED status display One programmable relay output 1000 Users Card PIN Card amp PIN Low power consumption 50mA Anti Tamper Alarm Latch Mode to hold door or gate open 12 24V DC Power input Specifications Operating Voltage 12 24V DC Idle Current 50mA Active Current 80mA Proximity Card Reader EM Radio Technology 125 KHz Industry Standard Proximity Card Read Range 25mm 35mm Relay One NO NC Common Adjustable Relay Output T
4. cific UserID The user ID is any number from 0 999 to associate the card to 4 Exit program mode Delete User Cards Programming Step Keystroke Combination 1 Enter Program Mode Master Code 2 Delete Card By card 2 Read Card Cards can be deleted continuously 3 Delete Card Select Specific D 2 User ID The user ID is any number from 0 999 4 Exit program mode Add or Delete a PIN Programming Step Keystroke Combination 1 Enter Program Mode Master Code 2 Add a PIN 1 User ID PIN Assigns PIN to user ID number PINS can be added continuously 3 Delete a PIN 2 User ID Deletes the User ID number and associated PINS can be deleted continuously PIN 4 Exit program mode Change a PIN This operation is executed from outside of Program Mode Programming Step Keystroke Combination 1 Change a PIN User 1D Old PIN New PIN New PIN 2 Exit program mode ACCESS CONFI GURATI ON CARD PIN Add a Card PIN User 4 Add PIN Read Card 1234 New PIN New PIN This operation is executed from outside of Program Mode Change PIN Allows card user to update the PIN for their card PIN User ID This operation is executed from outside of Program Mode Programming Step Keystroke Combination 1 Change PIN using a Card Read Card Old PIN New PIN New PIN 2 Change PIN using PIN User ID Old PIN New PIN New PIN Delete Card by User
5. d PIN or Master Code Programming Step Keystroke Combination 1 Enter Program Mode Master Code 2 Strike Out OFF 6 0 Default 3 Strike Out ON 6 1 Access will be denied for 10 minutes 4 Strike Out ON 6 2 The buzzer alarms 5 Set alarm time 5 0 30 Default is 1 minute 6 Exit program mode Programming 2 Program Cards and PINS Programming will vary depending on the access configuration Follow the instructions according to your access configuration GENERAL PROGRAMMING INFORMATION User I D Number Assign a user ID number to the access code in order to keep track of the users of access cards or PINS The user ID number can be any number from 1 1000 IMPORTANT User IDs do not have to be proceeded with any leading zeros Recording of User ID Is critical Modifications to user data require either the card or the User ID be available Proximity Card 125 KHz industry standard 26 bit EM Proximity Card e Keypad PIN The PIN can be any 4 6 digits between 0000 999999 except 1234 which is reserved for factory testing ACCESS CONFI GURATI ON CARD OR PIN amp CARD ONLY Add User Cards Programming Step Keystroke Combination 1 Enter Program Mode Master Code 2 Add Card Using Auto ID 1 Read Card Allows K401 I to assign Card to next Cards can be added continuously available User ID number 3 Add Card Select Specific ID 1 User ID Read Card Allows manager to define a spe
6. ime 1 99 Seconds 5 seconds default Lock Output Load 3 Amp Maximum Environment Indoor Operating Temperature 30 C 60 C Operating Humidity 20 RH 85 RH Physical Zinc Alloy Enclosure Surface Finish Powder Coat Dimensions L 120 x W 76 x D 25 mm Unit Weight 490g Shipping Weight 600g Package contents K401 I Keypad Diode IN4004 For relay circuit protection Sehe Self Tapping Screws Purun a aee Wall Anchors Screw Driver INSTALLATION e Remove the back cover from the unit e Drill 2 holes A C on the wall for the screws and one hole for the cable e Knock the supplied rubber bungs to the screw holes A C e Fix the back cover firmly on the wall with 4 flat head screws e Thread the cable through the cable hole B e Attach the unit to the back cover Wiring Wire Insulation Colour Function Request to Exit input REX Rea powers 12 24 DC Regulated Power Input G Ground C Bak ND Bue NO Normally Open Relay Output ND OM C E a taal iies Normally Closed Relay Output Connection Diagram Examples Common power supply for magnetic lock Fail open power to lock a oN YN YN Reed ea JW clloyffeurni AK Blue ANa 12v or 24v DC PSB 1 Open C NO fNC 12v or 24v DC Power Supply N C or 3 PRESS TO Exit 240v 5 amp Fused Spur Supply Ensure magnetic lock is set to 12v or 24v dc operation before testing Optiona
7. l exit button Common power supply for lock release Fail secure power to unlock YN f N YN ary wie oN yf N 12v or 24v DC Open C NO NIC PSB 1 12v or 24v DC Power Supply PRESS Ej TO EXIT L2 240v 5 amp Fused Spur Supply Ensure lock release is set to 12v or 24v dc operation before testing Optional exit button Common power supply for auto gate controller using Normally Open contact EN YN ros f N YN YN Reed AS AY cllopfReurnid Bus Nrang 12v or 24v DC SB 1 Open C N O NC P 12v or 24v DC Power Supply 240v 5 amp Fused Spur Supply To gate controller TO EXIT Optional exit button Attention nstall a 1N4004 or equivalent diode across the locking device when using a common power supply to prevent any back E M F as the reader might damage 1N4004 is included in the packing PROGRAMMI NG Programming will vary depending on access confirguration Follow the instructions according to your access configuration Programming 1 Configure the K401 I Change the configure settings according to your application optional Multiple configuration settings can be changed at one time enter program mode change the desired settings then exit program mode Set Master Code The 4 6 digit Master Code is used to prevent unauthorized access to the system To interface with the K401 1 the manager will need a Master Code factory default code 6666
8. peat New Master Code code 4 6 digits Add Card User 1 Read Card Add PIN User 1 User ID PIN The ID number is any number between 0 999 The PIN Is any 4 6 digits between 0000 999999 Delete User 2 Read Card 2 User ID How to be granted access