1. ENTRANCE _ 4 Once the basic programming is complete press END on the VM81 handheld programmer until you exit the menu system to save the settings Check Communications Once you have configured the above settings you are now ready to check communications between the Monitoring Station and the Fast Scan Contact your Monitoring Station and confirm the site details i e SITE ID CMS PASSWORD PHONE NUMBER The Monitoring Station should then attempt communication with the Fast Scan and verify that they can obtain video Ready to Complete the Installation Once the above steps have been completed the basic operation of the Fast Scan has been confirmed You are now ready to complete the programming of the unit as well as finalise the installation of any other equipment such as alarm sensors audio equipment and PTZ camera stations Please refer to the Fast Scan Installation and User Manual for further installation and configuration details Troubleshooting Tips e Ensure that matching Site ID and CMS Password details are entered at the Fast Scan and the Monitoring Station e If using a network connection ensure the TCP IP address and subnet mask are correct The manufacturer reserves the right to change designs or specifications without obligation and without further notice ADPRO FastTrace FastVu Fast Scan Axiom PRO Amux and Video Central are brands and trademarks used under licence by the distributor Printed
2. November 2003 P N 201576 01 Vision Systems Quality System
3. ADPRO Fast Scan Quick Setup Guide Use this guide for the first time setup of an ADPRO Fast Scan Remote Video Transmitter For details of configuration of a Receiver please refer to the Fast Scan Manual The setup procedure is the same for rack mount and wall mount versions Unpack the ADPRO Fast Scan and check for signs of damage If any damage is found before installation please report to your supplier Check the carton contents In addition the Fast Scan wall mount includes e ADPRO Fast Scan e 0 4m Velcro strip e ADPRO Fast Scan Installation and Setup Manual e 11 blanking plugs e 20 way ribbon cable connector e 5 cable ties e 15 way D connector e 5 mounting platforms e 3x9 way D connector e Cabinet keys e 15 way screw terminal plug e 12V power supply NTSC version only e 2 way screw terminal plug for dc power e Mains power cable rack mount only e 25 pin D to 25 pin D modem cable e 4x mounting bolts and washers Extra equipment and information that you will require for initial configuration includes e M81 handheld programmer or AMK 300 keyboard e 3A 12Vdc regulated power supply PAL wall mount version only e Composite video monitor e Atleast one camera e Communication device either a PSTN Modem ISDN Terminal Adapter or Router with an Ethernet interface and an MSS100 Terminal Server e Contact details for the Monitoring Station and their Technical Support in confirming the Communications between the Moni
4. anual SETUP MENU MODE OF OPERATION AGAO S EPa TRANSMITE MODE OF OPERATION fii ALL ALARMS C ACTIVE TRANSMITTER SETUP z PHONELINE TYPE C TONE DIALI RECEIVER SETUP GENERAL SETUP UMD CONTROL LANGUAGE C ENGLISH GENERAL RELAY ALARM J AUDIO DEVICE LUMZZAJ RX 162280009 V1 60C GENERAL SETUP HETVORK SETUP NETWORK SETUP MODEL SECURE POLL SETUP BAUD RATE ji USER MODEM SETUP DIAL TIME Seconds DIAL TRIES COMMS LINK SETUP PRINTER SETUP AASWER RINGS L PTZ SETUP i IF ADDRESS c PTZ ADDRESS SETUP SUBNET MASK L GATEWAY ee teeth E DESHKPORTE 2 0 0P 8 C S7600 TX 102200097 V2Z 3C 201576 01 Page 3 Vision Fire amp Security ADPRO Fast Scan Quick Setup Guide Configure Camera At least one camera must be configured for initial operation From the top level setup menu select TRANSMITTER SETUP then CAMERA ID and program the camera name of camera 1 Ensure the camera is plugged into the camera 1 input on the rear of the unit SETUP MENU MODE OF OPERATION TRANSMITTER SETUP RECEIVER SETUP GENERAL SETUP c TRANSMITTER SETUP UMD CONTROL SITE ID CAMERA ID RX 102200097 V1 98C CALL LIST TINE DATE TRANSMITTER OPTIONS ALARM OPTIONS GUARD TOUR DISPLAY CHANNELS CAMERA ID OOOOOOO z ENTRANCE DEPARTURE ARRIVALS CANTEEN LUGGAGE STORAGE NORTH WEST FENCE ajaja TH 1822660097 1 68C 1 zZ 3 4 5 6 7 8 9 B ajajajaj 1 CAMERA ID
5. he Video Out on the rear panel of the Fast Scan to the video input of the composite monitor e Connect the communication device to the Modem port The communications equipment itself may require configuration please refer to the manual provided with the communications interface for configuration requirements e Power up all equipment e The green Power LED will power on If the red Status LED switches on and stays on there is a fault with the unit The unit will take approximately 20 seconds to perform its self tests to to Dial OR to Dial OR 10BaseT or Dedicated Dedicated 100BaseTx Phone Lines 7N Lines X 21 ISDN Network Adaptor Gates Access T Control T s 2 aA Doors Horn Lights yr D a 10 Control Outputs 5 Za 5 ON oO E or LA E F 5 Equipment 5 2 Suitable supporting xe o S 8 Interface RS232 General Alarm Relay Output z Circuitry 5 3 Serial Data ramuanicaicas Access Secure Input vse Delayed Connect Input J l X 21 Adaptor Wi H Alarm Control Outputs RS485 232 Config SSSA Gay Connector Panel Exo E a ee es okno Ofer of the Fast Scan Keyboard Modem lt 66 66 OOO 6 series Ill Transmitter 12V DC Alarm Control Inputs 12 V 12345678910 JRO GND1C23C45C67C89C 10 RS485 Video Terminations Video O 12V DC Input Up to 10 Cameras 10 Alarm a 026021000114 er O Microwave Monoch
6. nter the SITE NAME PASSWORD and CMS PASSWORD For more detailed instructions please refer to Section 3 9 in the Fast Scan Installation amp User Manual SETUP MENU TRANSMITTER SETUP SITE ID SITE MAME BUS DEPOT PASSYVORD ABCDI4S44 CHS PASSWORD 1234 ACD SITE ID CAMERA ID CALL LIST TIME DATE TRANSMITTER OPTIONS ALARA OPTIONS GUARD TOU DISPLAY CHANNELS MODE OF OPERATION TRANSMITTER SETUP RECEIVER SETUP GENERAL SETUP UND CONTROL OOOOOOO RX 162260097 V1 060C TH 1822660097 1 68C Configure Communications Devices The next step is to configure the Communications link Select MODE OF OPERATION from the top level of the menu and then PHONELINE TYPE Set the PHONELINE TYPE to match your specific link typically for any dialup or network connection this should be set to TONE DIAL Go back to the top menu level and select GENERAL SETUP then select NETWORK SETUP Configure the NETWORK SETUP to match the communications link that is being used For more detailed information please refer to section 3 9 4 in the Fast Scan Installation and User Manual If the modem TA type being used is not listed and a USER DEFINED HAYES option is selected then the USER MODEM SETUP may also require modification to enter any specific AT commands for the modem TA If the MSS 100 Server is used the USER DEFINED HAYES option must be selected For more detailed information please refer to section 3 9 4 in the Fast Scan Installation and User M
7. rome Fence Access MONITOR Detector Control for programming fs2 capttx cdr Accessing the Fast Scan User Settings menu Once the Fast Scan has powered up successfully you are now ready to SETUP MEN access the setup menus To achieve basic functionality and check communications with the Monitoring Station the following steps are required MODE OF OPERATION TRANSMITTER SETUP e Set Transmitter Receiver Mode RECEIVER SETUP e Program Site ID and Password UMD CONTROL e Configure Communications Devices e Configure Camera e Check Communications RX 1622080697 V1 G66C 201576 01 Page 2 Vision Fire amp Security ADPRO Fast Scan Quick Setup Guide Set Transmitter Receiver Mode Once the unit has booted up press MODE on the VM81 handheld programmer or SETUP on the AMK 300 keyboard and the setup menu of the Fast Scan should be displayed on the composite monitor Select MODE OF OPERATION and then select TRANSMIT under TRANSMIT RECV by pressing the ENTER key to toggle the selection then press END to exit SETUP MENMU MODE OF OPERATION Oi ites TRANSMITE ALL ALARMS C ACTIVE PHONELINE TYPE C TONE DIALI HODE OF OFERATIOH TRANSMITTER SETUP RECEIVER SETUP GENERAL SETUP UHD COHTR L LANGUAGE C ENGLISH GENERAL RELAY ALARM J AUDIO DEVICE LUMZZAJ RX 102200097 U1 BOC Program Site ID and Password To program SITE ID and PASSWORD from the top level menu select TRANSMITTER SETUP select SITE ID and then e
8. toring Station and the Fast Scan e The CMS should also issue the Site ID and CMS Password as well as the contact number for Video Central or FastScan Receiver and IP addresses if an Ethernet connection is used Check DIP Switch amp Chassis ID Settings The DIP switches and Chassis ID Hex switch on the rear of the unit determine the unit s functionality at power on f configuring a multi chassis transmitter please refer to section 2 23 in the Fast Scan Installation and User manual If configuring a single transmitter the Chassis ID Hex switch should be set to 0 and S3 can be set ON or OFF depending if you wish to enable FAST BOOT MODE N kN _ Alarm 7 o Chassis i KO UO00 4 mug C 10 RS485 Vi Keo Terminations Video O a NN x fs2 chass swi iteh cdr DIP switch S 3 FS2 S3 PIN CDR 201576 01 Page 1 Vision Fire amp Security ADPRO Fast Scan Quick Setup Guide Fast Scan Connections and Power On Sequence e Plug the VM81 handheld programmer into the Keyboard port on the rear of the unit If using an AMK 300 keyboard please refer to Section 2 21 in the Fast Scan Installation and User Manual e Connect t