Home
DRM75A – 230V 20/100A User manual
Contents
1. 2007 1 3 Performance criteria Operating humidity Storage humidity Operating temperature Storage temperature International standard Accuracy class Protection against penetration of dust and water Insulating encased meter of protective class 1 4 Specifications Nominal voltage Un Operational voltage Insulation capabilities AC voltage withstand Impulse voltage withstand Basic current Ib Maximum rated current Imax Operational current range Over current withstand Operational frequency range Internal power consumption Test output flash rate RED LED Pulse output rate pins 2 amp 3 Power supply indicator Green LED Consumption indicator RED LED 1 5 Basic errors 1 6 Description 0 05Ib Coso 1 0 1Ib Cos 0 5L Cos 0 8C 0 1Ib Imax Cos 1 0 21b Imax Cos 0 5L Cos 0 8C A Front panel B Protection cover C Cover D Base E Security hasp DMMeteringg 2007 lt 75 lt 95 10 C 50 C 30 C 70 C IEC 62053 21 1 IP51 II 230V AC 161 300V AC 2KV for 1 minute 6KV 1 2uS waveform 20A 100A 1A 100A 3000A for 0 01s 50Hz 10 lt 2W 10VA 800 impulses per kWh 800 pulses per kWh Meter is connected and working OK Flashing at load running 1 5 1 5 1 5 1 0 1 0 1 0 Material Front panel Protection cover Cover Base PC inflammable retarding ABS inflammable retarding ABS inflammable retarding ABS inflamma
2. Fax 852 2911 1200 www inepro com hk info inepro com hk RoHS COMPLIANT o ail 2002 95 EC DMMeteringg 2007
3. 07 YV VVVVVVV Installation maintenance and repair should only be carried out by qualified personnel Never break the seals and open the front cover as this might influence the functionality of the meter and will void any warranty Do not drop or allow physical impact to the meter as there are high precision components inside that may break or render the meter measures inaccurate Exclusion of liability We have checked the contents of this publication and every effort has been made to ensure that the descriptions are as accurate as possible However deviations from the description cannot be completely ruled out so that no liability can be accepted for any errors or omissions contained in the information given The data in this manual are checked regularly and the necessary corrections are included in subsequent editions We are grateful for any improvements that you care to suggest Subject to technical modifications without notice Copyright Copyright DMMetering November 2007 All rights Reserved It is prohibited to pass on or copy this document or to use or disclose its contents without our express permission Any duplication is a violation of the law and subject to criminal and civil penalties All rights reserved particularly in the event of a patent award or utility model registration Registered trademarks DMMetering is registered trademark of Inepro Industries Ltd member of the Inepro Group The other names ap
4. DMMetering DRM75A 230V 20 100A DIN rail single phase two wire energy meter 1 1 Safety instruction 1 2 Foreword 1 3 Performance criteria 1 4 Specifications 1 5 Basic errors 1 6 Description 1 7 Dimensions 1 8 Installation 1 9 Operating 1 10 Troubleshooting 1 11 Technical support User manual DMMeteringg 2007 1 1 Safety instructions Information for Your Own Safety This manual does not contain all of the safety measures for operation of the equipment module device because special operating conditions and local code requirements or regulations may necessitate further measures However it does contain information which must be adhered to in the interests of your own personal safety and to avoid material damages This information is highlighted by a warning triangle and are represented as follows depending on the degree of potential danger Caution means hazard of electric shock and failure to take the necessary safety precautions will Warning means that failure to observe the instruction can result in death serious injury or considerable material damage A result in death serious injury or considerable material damage Qualified personnel Commissioning and operation of the equipment module device described in this manual may only be performed by qualified personnel Qualified personnel in the sense of the safety information contained in this manual are persons who
5. are authorized to commission start up ground and label devices systems and circuits according to safety and Regulatory standards Use for the intended purpose The equipment device module may only be used for the application cases specified in the catalog and the user manual and only in connection with devices and components recommended and approved by DMMetering Proper handling The prerequisites for perfect reliable operation of the product are proper transport proper storage installation and assembly as well as proper operation and maintenance When operating electrical equipment certain parts of this equipment automatically carry dangerous voltages Improper handling can therefore result in serious injury or material damage Use only isolated tools Do not connect while circuit is live hot Do not connect the meter to a 3 phase 400VAC network Place the meter only in dry surroundings Do not mount the meter in an explosive area or exposed to dust mildew and insects Make sure the used wires are suitable for the maximum current of this meter Make sure the AC wires are connected correctly before activating the current voltage to the meter Do not touch the meter connecting clamps directly with your bare hands with metal blank wire or other material as you will have the chance of an electricity shock and a possible chance for health damage Make sure the protection cover is replaced after installation DMMeteringg 20
6. ble retarding 1 7 Dimensions o POWER PULSE p E i EE Lv 1PHIGE 2 WIRE ENERGY METER Jel A i Wr DRM75A 1EC6 2053 21 800 imp k Wh zt 230VAC 20 100 A 50Hz Cx No DMMetering D Y Height 88 mm Width 75 mm Depth 68 mm Max diameter cable 11 5 mm 7 5mm with adaptor 1 and 4 9mm with adaptor 2 Weight 0 2 Kg net f EO jl O Omo O LO 2 DEN 4 IO l nf L1 LZ L2 N 76 o omg E ri 1 PHASE 2WIRE ENERGY METER M h EX s zd P ET po ET k W h Lm MV DRM75A 1EC62053 21 CeooJimpkWwh ma 230VAC 20 100 A 50Hz e No DmMetering F ER oo wF E 5 5 bo a DMMeteringg 2007 1 8 Installation DMMeteringg 2007 CAUTION gt Turn off and lock out all power supplying the energy meter and the equipment to which it is installed before working on it gt Always use a properly rated voltage sensing device to confirm that power is off A WARNING gt Installation should be performed by qualified personnel familiar with applicable codes and regulations gt Use isolated tools to install the me
7. des and regulations To prevent tampering secure the meter with a padlock or a similar device The meter has to be installed against a wall which is fire resistant The meter has to be installed in a good ventilated and dry place The meter has to be installed in a protection box when placed in dangerous or dusty environments The meter can be installed and used after being tested and sealed with a letter press printing The meter can be installed on a 35mm DIN rail or direct on a meter board with screws The meter should be installed in an available height so that it is easy to read When the meter is installed in an area with frequent surges due to e q thunderstorms welding machines inverters etc protect the meter with Surge Protection Devices After finishing installation the meter must be sealed to prevent tampering Connection of the wires should be done in accordance with the underneath connection diagram L2 N T N 3 TEST 2 J EE L amp L1 Phase wire L2 N Neutral wire 2and3 Pulse output contact 1 9 Operating Working amp consumption indication There is a LED which has two colors green and red in the front panel of DRM75A When the meter works normally this LED will constantly display green if there is consumption the LED will flash red The more quickly LED flash the more consumption there is For this LED
8. oo low the spacing interval of the flashes will take some more time this is why it seems like the LED isn t burning Please contact technical support to replace this meter The register can t run Is there a power supply inside the meter Is the operating power too low Maybe there is a fault in the inside circuit Check that the power supply indicator RED LED is burning If the operating power is too low the spacing interval of the pulses will take some more time this is why it seems like the register can t run Please contact technical support to replace this meter No pulse output Is DC power supply connected to the meter Is the connection correct Maybe there is a fault in the inside circuit Check the external voltage source Ui is 5 27V DC Check correct connection connect 5 27V DC to connector 3 anode and the signal wire S to connector 2 cathode Please contact technical support to replace this meter Pulse output rate wrong DMMeteringg 2007 Maybe there is a fault in the inside circuit Please contact technical support to replace this meter 1 11 Technical support For questions about one of our products please contact DMMetering dealer in your region Your local DMMetering distributor Email support dmmetering com www dmmetering com Inepro Industries Ltd Room 2308 Central Plaza 18 Harbour Road Wan Chai Hong Kong
9. pearing in this manual may be trade names the use of which by third parties for their own purposes may infringe the rights of the owners 1 2 Foreword Thank you for purchasing the DMMetering DRM75A DIN rail single phase two wire energy meter The DMMetering DRM75A energy meter is the most advanced type electronic kWh meter available at the market With the DMMetering product range we have introduced a large scale of energy meters on the market suitable for 110V AC to 400V AC 50 or 60Hz Besides the normal energy meters we also developed our own pre paid meters with chip card chip card re loaders and a complete PC management control system For more information on other product please contact our sales department at sales dmmetering com or info inepro com hk Although we produce the DMMetering DRM75A meter according to IEC 62053 21 and our quality inspection is very accurate there might always be a possibility that your product shows a fault or failure for which we do apologize Under normal conditions your product should give you years of benefit and pleasure In case there is problem with the energy meter you should contact your dealer immediately All energy meters are sealed with a special seal Once this seal is broken there is no possibility to claim for warranty Therefore NEVER open an energy meter or break the seal of the energy meter The warranty time is 6 months after installation and only valid for construction faults DMMeteringg
10. ter gt Fuse or thermal cut off or single pole circuit breaker can t be fitted on the supply line and not the neutral line gt Don t put finger into the hole because there is a cone screw inside gt Please choose the available wire centering adapter which is supplied with the meter to suit the diameter of the cable We recommend that the connecting wire which is used to connect the meter to outside circuit should be sized according to local codes and regulations for the ampacity of the circuit breaker or over current device used in the circuit An external switch or a circuit breaker should be installed on the inlet wire which will be used as a disconnection device for the meter And there it is recommendation that the switch or circuit breaker be near the meter so that it is convenient for the operator The switch or circuit breaker should comply with the specifications of the building electrical design and all local regulations An external fuse or thermal cut off which will used as an overcurrent protection device for the meter must be installed on the supply side wire and it is recommended that the overcurrent protection device be near the meter so that it is convenient for the operator The overcurrent protection device should comply with the specifications of the building electrical design and all local regulations This meter can be installed indoor directly or in a meter box which is waterproof outdoor subject to local co
11. the flash rate is 800 impulses per kWh When meter is going wrong or no power supply the LED will turn off Reading the meter The DRM75A energy meter is equipped with a 5 1 register which is used to record consumption and can t be reset to zero Five integers are marked with black colour and one decimal is marked with red The number system is based on units of 10 And unit is kWh O O op POWER PULSE AG CE 1 PHASE 2 WIRE ENERGY METER m m m 00000 0 kWh DRM75A EC62053 21 800 imp kWh 230VAC 20 100 A 50Hz NO DMMetering DMMeteringg 2007 Pulse output The DRM75A DIN rail energy meter is equipped with a pulse output which is fully separated from the inside circuit That generates pulses in proportion to the measured energy for remote reading purposes and accuracy testing The pulse output is a polarity dependant passive transistor output requiring an external voltage source for correct operation For this external voltage source the voltage Ui should is 5 27V DC and the maximum input current Iimax is 27mA DC To connect the impulse output connect 5 27V DC to connector 3 anode and the signal wire S to connector 2 cathode The meter pulses 800 per kWh 1 10 Troubleshooting DMMeteringg 2007 A CAUTION gt During repairing and maintenance do not touch the meter connecting clamps directly
12. with your bare hands with metal blank wire or other material as you will have the chance of an electricity shock and a possible chance for health damage gt Turn off and lock out all power supplying the energy meter and the equipment to which it is installed before opening the protection cover to prevent the hazard of electric shock A WARNING gt Maintenance or repair should be performed by qualified personnel familiar with applicable codes and regulations gt Use insulated tools to maintain or repair the meter Make sure the protection cover is in place after maintenance or repair Problem Check Solution No light for the Power supply indicator Green LED Is AC power supply connected to the meter Is the L1 and L2 N connecting correct Maybe there is a fault in the inside circuit Check switch or circuit breaker and fuse or thermal cut off Reinstall terminal screws on the L1 and L2 N Make sure all screws are fixed Than there should be a 230V 50Hz AC voltage between the terminal screws on the L1 and L2 N when power supply is input Please contact technical support to replace this meter Continue Problem Check Solution No light for the Is the load Only when load is running this consumption running LED will flash indicator RED LED Is the operating power too low Maybe there is a fault in the inside circuit If the operating power is t
Download Pdf Manuals
Related Search
Related Contents
CTime User`s Manual Software Industry LCD-AD222Eシリーズ 取扱説明書 Samsung Galaxy Tab S (10.5, Wi-Fi) Lietotāja rokasgrāmata(Lollipop) HP b3000 Installation Guide サンワ*完格サィン 取扱説明書 Case Logic QPB-201 User manual Mollosil BPZ-(20332)-150811.indd DRM GPS - User manual manual de instalação Stûv 30 Copyright © All rights reserved.