Home
HydraPump Pro™
Contents
1. Inspect the general condition of the pump Check for loose screws misalignment or binding of moving parts cracked or broken parts damaged electrical wiring and any other condition that may affect its safe operation AFTER USE Unplug the pump and let it cool if hot Remove the hose connections the brass hose connectors do not need to be removed Carefully tilt and drain all excess water from inside the pump Lastly clean external surfaces of the pump with clean cloth SPECIFICATIONS e y HP Single Phase 120V 60Hz 8 4A e Pumping Capacity 1500 GPH Max e Inlet amp Outlet Size with brass adapter Standard Garden Hose Size Copyright Watershed Innovations All rights reserved HydraPump Documentation Rev 1 0 REFERENCE PARTS LIST PARTS LIST REFERENCE Part Description Rubber Foot Pump Facing Hose Fitting Priming Plug Pump Gasket Impeller Pump Impeller Fitting Pump Seal Gasket Pump Back Wall Bearing 600 Armature Bearing 608 Screw m 4 x 60 Stator Pump Housing Carbon Brush Cap Carbon Brush Carbon Brush Holder Screw Quantity NNNNRP PNP RP RP RP RP RRP RP PDR WwW Copyright Watershed Innovations All rights reserved HydraPump Documentation Rev 1 0
2. HydraPump Pro Owner s Guide Copyright Watershed Innovations All rights reserved HydraPump Documentation Rev 1 0 USAGE GUIDE NOTE This Water Pump has been designed to operate on 110 120 Volt 60 Hz exclusively Using any other voltage or Hz adversely affects performance IMPORTANT Keep this guide for future reference CAUTION Be sure to review SAFETY INSTRUCTIONS FIRST PERTAINING TO A RISK OF FIRE ELECTRICAL SHOCK OR INJURY TO PERSONS before using the pump TOOLS AND MATERIALS YOU MAY NEED e Absorbent cloth or HydraTowel to for clean up and maintenance e Standard hoses for inlet and outlet e Small water container for priming the pump e PTFE tape sometimes this is referred to as plumber s tape PACAKAGE CONTENTS 1 piece HydraPump 2 piece Brass hose Adapters 1 piece Repair and maintenance kit Copyright Watershed Innovations All rights reserved HydraPump Documentation Rev 1 0 SITE PREPARATION Make sure your work area where you intend to use the pump is clear of clutter and well lit Also ensure that the pump is in a location that it will not be submerged or in contact with external water The pump is designed to pump fresh water so please make sure that the water source does not contain large bits of debris IMPORTANT SAFETY INSTRUCTIONS INSTRUCTIONS PERTAINING TO A RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS SAVE THESE INSTRUCTIONS WARNING When u
3. ake sure that the end of the outlet hose is connected correctly Prime the pump as described in the previous section Carefully plug the pump into a 3 wire 120 Volt 60 Hz grounded A C Outlet to begin operation a Water should being to flow in 30 seconds or less b Ifwater does not flow unplug the pump and recheck the connections and setup Re prime the pump and try again c Note that operation the pump without water for an extended period may dame the pump and cause it to fail 6 Once pumping has completed unplug the pump a Be aware that the pump may become hot during operations Be careful when working near or touching the pump oS le CAUTION Water and electricity do not mix Make sure to continuously check that the power connections and cables are not in contact with water Consult an electrician if you have any questions or concern about the electrical circuit or pump operations Copyright Watershed Innovations All rights reserved HydraPump Documentation Rev 1 0 TROUBLESHOOTING Possible Causes Possible Solutions Pump will not start No power or cord Check outlet power not connected or plug in pump Wornoutor Replace carbon damaged brushes brushes Pump operates but does Pump is not Prime pump per not pump water primed instructions No water to pump Find an alternative Impeller is worn source of water out or jammed Repair or replace impeller CLEANING AND MAINTENANCE BEFORE EACH USE
4. d with a cord having an equipment grounding conductor and a grounding plug The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances ELECTRICAL CONNECTIONS A Connect pump to 110 120 Volt 60 Hz AC current only B Use a three prong plug see figure below CS 8 Prong Plug and Outlet CAUTION Do not allow the casing pump electrical cord or electrical outlet to come into contact with water This may result in serious injury If unsure of how to install or use this pump consult a licensed electrician Copyright Watershed Innovations All rights reserved HydraPump Documentation Rev 1 0 PUMP PRIMING AND OPERATING INSTRUCTIONS PUMP PRIMING Before operation the pump must be primed To prime the pump for operation water must be added to the pump via the water cap on the top of the unit Ensure that the unit is unplugged and remove the water cap as shown below using a wrench TRATTA ve Once the cap has been removed add water to the chamber as shown below until the pump is full of water some may spill out Replac gt Gud Copyright Watershed Innovations All rights reserved HydraPump Documentation Rev 1 0 OPERATING The following are the steps for pump operation Connect standard garden hoses to the inlet and outlet of the pump Verify that the inlet hose is connected or submerged into a water source M
5. sing electrical pumps basic precautions should always be followed including the following 1 Readall instructions before using the pump 2 To reduce the risk of injury close supervision is recommended at all times that the pump is in operation 3 Do not put fingers or hands into a water pump inlet our outlet when operating 4 Unplug the power before attempting to move the pump 5 For proper grounding instructions see the ELECTRICAL CONNECTION portion of this manual Copyright Watershed Innovations All rights reserved HydraPump Documentation Rev 1 0 HOSE AND ELECTRICAL CONNECTIONS HOSE CONNECTIONS First install the 2 brass hose adapters to both the inlet and outlet of the pump Although not required for a better seal on the brass adapters it is recommended that you use PTFE tape on the threads that go into the pump Attach the adapters as shown below Once the brass adapter has been installed attach a standard garden hose to each of the inlet and outlet Note The outlet is labeled as OUT and the inlet is labeled as IN on the pump housing Copyright Watershed Innovations All rights reserved HydraPump Documentation Rev 1 0 GROUNDING INSTRUCTIONS THE WATER PUMP IS EQUIPPED WITH A GROUNDED PLUG IN POWER CORD This pump must be grounded In the event of a malfunction or breakdown Grounding provides a path of least resistance for electric current to reduce the risk of electric shock This pump is equippe