Home
CheckLine`s HLL1/HLL1W Manual
Contents
1. If there are any points in this manual that you are unsure of seek a competent trained person to advise you before using Seek medical advice from a doctor before using this product if you have sustained a spinal injury suffer from a neck or back complaint or you are taking prescription medication Never use if you are under the influence of alcohol or recreational drugs Extra care should be taken if welding whilst using this product protect the anchor from splatter and heat at all times Never use this system unattended Never use this system unless you are trained on proper use of this system Rescue Planning When using the ecoAnch or users should always make suitable provisions for rescue A full risk assessment should be carried out to determine the most effective safe and quickest form of rescue For more information on specialty rescue systems or training please contact Guardian Fall Protection Quality Legislation Exclusions 5 1 Quality The Guardian ecoAnchor is strictly manufactured under ISO 9001 2000 and to the highest standards The scope of use within the certification held allows Guardian to design manufacture and test Personal Protection Equipment Horizontal tensile test machine abrasion testers and dynamic drop test rig are just part of the full range of test facilities used to ensure ultimate safety of our product range All Guardian systems must only be installed by Guardian pers
2. full is 948 lbs with a distributed load of 56 Ibs per square foot Inspect the anchor for signs of damage or leakage Inspect the attachment point for signs of wear or damage Do not use the anchor if either the bag or attachment point show signs of damage If the anchor is used on a roof surface of felt chippings loose chippings must be removed from the area where the anchor is to be positioned e g by sweeping with a stiff brush before deployment of the anchor Issue 2 User Manual Page 6 ecoAnch or Installation amp System Setup Section 3 1 1 Remove from carry bag unfold amp position the anchor so as to maximize the contact area between the base of the anchor amp the roof 2 Avoid areas where there are projections e g bolts ridges etc Do not position the anchor in areas where water accumulates 3 The anchor must be positioned as indicated on the label with the vent at the highest corner amp the drain at the lowest point The vent allows air to escape amp prevents the over pressurising Incorrect positioning can result in trapped air amp underfilling making the anchor unsafe 4 The anchor is filled with cold water by simply fitting a hose with an outside diameter of 5 8 in to 3 4 in into the filler spout with the rubber bung removed Filling is complete when water begins to flow from the diagonally opposite vent valve The anchorage connection is located in the middle of the anhor To d
3. TD 191 Pt 1520 gt 700N Issue 2 User Manual Page 4 ecoAnch or Storage Issue Inspection Section 2 0 Storage This device should be stored in a clean dry place where it can be protected from damage by chemical attack and sharp objects It should be stored with its instructions and record card at all times Return the device back to it s original holdall for storage amp transportation After use return to storage never leave the device lying around site Issue This and associated equipment must be visually inspected by a competent person when initially delivered to site there after the product must be inspected before and after use A inspection form is printed on page 10 of this manual and should be updated after each routine inspection Follow the points laid down in the section headed Inspection without deviation The competent person must ensure that the equipment is being used correctly and that the user is aware of its safe use and inspection Inspection Inspect the device for damage or leakage Inspect the attachment point for signs of wear or damage Ifin doubt quarantine and remove from service To clean the anchor a mild detergent can be used with warm or cold water amp left to dry naturally before storing Ensure that device certification is current before use the device must have been recertified within the last 12 months and 6 months if used in corrosive or off shore environments If for any
4. User Manual ACOANC r SAFETY BY DESIGN 1 0 2 0 3 0 4 0 5 0 6 0 Introduction to ecoAnch or amp Scope of Use Storage Issue amp Inspection Installation and System Setup Anchorage Compatibility amp Warnings Quality Compliance amp Exceptions Inspection Sheet Issue 2 User Manual Page 2 ecoAnch or index Issue 2 User Manual Page 3 ecoAnchor Introduction to the Section 1 0 ecoAnch or amp Scope of Use Guardian Fall Protection Water Weight Anchor ECOANC h o r The Checkmate ecoAnch or has been designed for your safety when working at height The anchor is a totally unique concept in fall protection amp uses renewable resources for both manufacturer amp installation The ecoAnch or is compatible with a large variety of roof surfaces including composite amp mineral felts It has been independently tested amp exceeds the ANSI Z359 6 standard amp even works on roof pitches to 5 degrees For a full list of approved surfaces amp roof angles please see ecoAnch or supplement available on request from Guardian The anchor is safe to use on wet surfaces but NOT shiny or slippery surfaces When collapsed the ecoAnchor weighs just 18 lbs fits into a small bag for easy installation Principal Features Material Neoprene Coated Fabric Dimensions 4 75 x 4 75 x 8 Weights Empty 18 Ibs Full 948 lbs Pressure Loading 39 PSI Puncture Resisitance Meets FED S
5. e Install the device so that it is away from the edge so avoiding swing hazards minimum 8 feet Never install where there is a possibility of electric shock hazards When installing ensure that you are not subjecting your self to potential fall hazards wear a full body harness and shock absorbing lanyard anchoring yourself while installing Use Fall Protection Follow the inspection routine laid down in this manual Do not use the device in situations where there is less than 11 5 feet of ground clearance Connect a lanyard from the anchor to the Rear Dorsal D ring of a fall Protection Full Body Harness Ensure that the hook of the device is secure in the Harness D Ring and that the gate of the hook is locked Never run or jump while attached to the anchor Issue 2 User Manual Page 8 ecoAnch or Section 4 0 Compatibility The anchor is suitable for fall arrest when used in conjunction with a Full Body Harness to ANSI Z359 1 07 Suitable lanyards for connection are to be compliant with ANSI Z359 1 07 or ANSI Z359 13 07 This unit is not suitable for use in explosive environments Please contact Guardian Fall Protection for any questions you have in regards to product compliance Warnings Read and understand manufacturers instructions before inspection installation or use of this product Never use this product if you weigh more than 310 lbs Only use approved equipment with this product
6. etach the hose squeeze the spout remove the hose amp replace the bung The anchor should now be completely full of water any air that can be felt in the bag can be exhausted through the vent Installation amp System Setup Daily Inspection 5 If the anchor is left filled and in position for more than 24 hours it must be inspected for each working day for leakage by ensuring the material near the vent is taut If neccessary refill the bag until water is seen to come out of the vent After Use 6 Empty the bag by unscrewing the drain cap When almost empty lift the the bag to remove the remaining water 7 If the external surface of the bag is wet leave to dry before folding 8 Fold twice as shown in photo carefully expelling any remaining air until relatively flat 9 Roll lengthways until compressed into a small roll and secure with fitted straps 10 Store anchor back into its bag it is now ready for reuse Issue 2 User Manual Page 7 ecoAnch or Section 3 2 Anchorage Compatibility amp Warnings Installation The Device must not be installed where the following hazards may endanger the user or prevent the efficient operation of the system The area below the device must be free of obstruction that will prevent the free pay out of lanyard or rope or may obstruct the movement of the user The environment must be free of heavy solvents or acids that will degrade the devic
7. onnel or an approved installer Strict training is given and written exams are completed before full certification can be given to installers 5 2 Legislation and Standards The ecoAnchor has been designed to meet ANSI Z359 6 07 Issue 2 User Manual Page 9 ecoAnch or Section 5 0 For clarification on any certification issues contact Guardian 5 3 Exclusions Guardian will NOT be responsible for a users who are out of the scope of any written manuals of training given b any systems that have NOT been inspected under the current requirements c operators who do not use load limiting devices d devices that have been damaged e when the Max weight in lbs has been exceeded f devices that have NO serial number markings and the manufacturers name is not present Issue 2 User Manual Page 10 ecoAnchor Record Card Section 6 0 SERIAL NO DATE PRODUCT CODE USER DATE CONDITION OF SYSTEM INSPECTED BY Record Card continued CONDITION OF SYSTEM Issue 2 User Manual Page 11 ecoAnch or Section 6 0 INSPECTED BY Approved service company Guardian Fall Protection 26609 79th Ave S Kent WA 98032 Ph 800 466 6385 Fax 800 670 7892 www guardianfall com
8. reason the inspection of this device shows signs for concern or doubt the device must be quarantined and removed from service immediately Qualification should be sought from the competent person and if still concerned the device must be sent to the supplier an approved service agent or the manufacturer for service and recertification This device must only be serviced by a trained and competent individual Never attempt to service this unit or tamper with its function in any way Issue 2 User Manual Page 5 eco Anch or Installation amp System Setup Section 3 0 Before Use Only ONE person may be attached to the anchor at any time Minimum ground clearance 11 5 feet Minimum distance from edge 8 feet The anchor MUST NOT be used in the following conditions Where there is a risk of frost or in freezing conditions Where there is contamination of the roof surface and or anchor by oil grease or other lubricants or by algae The anchor is approved for use ONLY on the following surfaces at a maximum pitch of 5 degrees 1 in 12 within the scope of ANSI Z359 6 Concrete Tarmac Felt amp mineral EPDM membrane Felt amp chippings loose chippings must be removed For a full list of approved surfaces amp roof angles please see ecoAnch or supplement available on request from Guardian Before use ensure that the surface you are working on is capable of supporting the weight of the anchor The weight of the anchor when
Download Pdf Manuals
Related Search
Related Contents
20L-UM001 - Literature Library DSW218A-D Smoke Alarm User's Manual User Manual Manuel - Interfocos Untitled AVSI-IP2 Interview Room System Setup Guide Guia de instalação Manual de instalação Slider Comet GT/GTR 250 EDITAL 319 - RP - PI - equipamentos médicos Philips BDP3282 User Guide Manual NB-DMA2800 User Manual Copyright © All rights reserved.