Contents

1. T8 CT failure Broken or shorted wires to the Service intervention is needed temperature sensor of the heat pump condenser T9 ET and CT Broken or shorted wires to Service intervention is needed failure these temperature sensors TA SUT and CT Broken or shorted wires to Service intervention is needed failure these temperature sensors TB ET SUT and CT Broken or shorted wires to Service intervention is needed failure these temperature sensors TC AT and CT Broken or shorted wires to Service intervention is needed failure these temperature sensors TD ET AT and CT Broken or shorted wires to Service intervention is needed failure these temperature sensors TE SUT AT and Broken or shorted wires to Service intervention is needed CT failure these temperature sensors TF ET SUT AT Broken or shorted wires to Service intervention is needed and CT failure these temperature sensors An error is indicated when the temperature measured by these temperature sensors is lower than 50 C or when the temperature measured at the compressor outlet ET is higher than 135 C or when the temperature measured at the heat pump outlet OT compressor suction SUT heat pump evaporator CT or ambient outdoor temperature AT is higher than 90 C When any of the temperature sensors of the heat pump is shorted the display of the heat pump or the connected PC shows the temperature of 150 C when the temperature sensor is broken
2. Use the dial knob to set the required temperature in the range from 0 to 65 C After confirmation the prompt appears Save Y N XX Press the confirmation button to save the settings The confirmation message Saved OK briefly appears and then the display returns one level back Use the dial knob to set the other temperatures or select and confirm the Return option to exit this menu 30 Heat pump operation User level v 1 04 Setting the Stop Temperature for Heating the HeW This menu allows to set the maximum temperature of the heating water in the HeW tank If the higher temperature than the set stop temperature is not required when using the equithermal control mode the heat pump stops heating When the status line is displayed press the confirmation button to enter the main menu and use the procedure described in chapter 7 1 2 on page 28 to open the Temperature settings menu After opening this menu use the dial knob to select the HeW stop temp option Temperature settings HeW stop temp Hew After opening this menu display shows HeW stop temp Hew XX Use the dial knob to set the required temperature in the range from 0 to 65 C After confirmation the prompt appears Save Y N XX Press the confirmation button to save the settings The confirmation message Saved OK briefly appears and then the display returns one level back Temperature settings H
3. If the module is not installed or is not functioning properly the LAN WAN settings menu can not be opened 56 Heat pump operation User level v 1 04 After opening the LAN WAN settings menu you can use the dial knob and the confirmation button to select and edit required parameters to connect the heat pump to LAN WAN network Assigned IP Displays the assigned IP address of the heat pump address Preset IP Setting the method for allocating IP address of the heat address pump If dynamic allocation of IP address is used the IP is assigned by DHCP server if the static IP address is set this item is used to enter the static IP address Network mask lf dynamic allocation is used the Network mask is assigned by DHCP server if the static IP address is set this item is used to enter the Network mask Gateway Ifdynamic allocation is used the Gateway address is assigned by DHCP server if the static IP address is set this item is used to enter the Gateway address DNS If dynamic allocation is used the DNS address is assigned by DHCP server if the static IP address is set this item is used to enter DNS address FTPS Setting the address to which the data about the heat pump operation will be transferred This is needs to remote access to the heat pump PING address Setting the IP address to verify the connection of the heat pump to Internet network MAC address Displays the MAC address of the he
4. 16 Heat pump operation User level v 1 04 Daily Heating Temperature Corrections This menu allows to set up to 8 daily corrections of the heating water temperature in one or two heating circuits for the equitherm control mode or up to 8 daily corrections of the air temperature in the reference room for the reference room temperature control mode All set corrections are entered into the pre selected current temperature correction register The temperature corrections of the heating water temperature used in the equitherm control mode and the temperature corrections of the air temperature used in the heating control mode according to the reference room are stored separately in two sets of registers which are switched automatically when the heating mode is changed This means that all the operations described here will be carried out only in one set of registers corresponding to the currently used control mode When the status line is displayed press the confirmation button to enter the main menu and use the procedure described in chapter 7 1 1 on page 14 to open the Heating settings menu Use the dial knob to select the option for temperature correction programming Heating settings Temp corr program After opening this menu use the dial knob to select the option for daily temperature correction programming Temp corr program Daily After opening this menu Daily moves to the top line of the displa
5. 3 1 Heating in Normal Mode According to your settings the heat pump can heat the domestic hot water the heating water for one or two heating circuits and the water in the pool The heating control method depends on the heating mode heating can be controlled according to the outdoor temperature equitherm control weather compensated control according to the temperature in the reference room or in the Emergency mode The heating mode can by set in the menu Heating settings Please see the chapter 7 1 1 on page 33 for description of the different heating modes When the equitherm control is selected the required heating water temperature in heating circuits is determined by equitherm curves according to the outdoor temperature The control electronics sets the heating water temperature according to the outdoor temperature to ensure a desired thermal comfort and to avoid unnecessary overheating of the building The shape of the equitherm curves depends on the heating system and the thermal insulating properties of the building For this reason you may need to adjust the preset equitherm curves during the first heating season The equitherm control controls the heating water temperature therefore the time and manual temperature corrections regulate the heating water temperature When the control according to the temperature in the reference room is selected the equitherm controls is also partly used to ensure the adequate response of the heating
6. Heat pump operation User level v 1 04 2 Heat Pump Main Menu After initial tests the display will enter the default state with the status line displayed From this default state you can enter the main menu by pressing the confirmation button in the centre of the dial knob If the display is not in the default state you must first use the dial knob in order to restore the default state and then you can enter the main menu by pressing the confirmation button Select the menu items by turning the dial knob and confirm the selected item by pressing the confirmation button This takes you to the next level of the menu submenu You can proceed in the similar way to enter the other embedded levels To exit the menu after setting the desired parameters or to exit the menu without making any changes each menu contains Return item to leave the menu When you select and confirm Return item you will move one level back to the previous level You can repeat this to return to the default state To quickly return to the default state you don t need to go back level by level as described above Just hold down the confirmation button for about 3 seconds When the default state of the heat pump is displayed CFP OFF 10 52 AT 2 4 CT 6 8 press the confirmation button to enter the Main menu Menu Heating When an error is detected after entering the menu the red LED lights up on the display and the menu contains only item
7. Use the dial knob to select the Setup option Menu Setup 51 Heat pump operation User level v 1 04 After opening this menu Setup moves to the top line of the display Use the dial knob to select the Info option on the bottom line Setup Info After opening this menu Info moves to the top line of the display Use the dial knob to select the HP Errors list option on the bottom line Info HP Errors list After opening this menu the display shows HP Errors list New errors Using the dial knob and the confirmation button you can select and view the following options to display the error lists New errors Displays the last 96 errors of the heat pump operation which have occurred since the last reset of the register of new errors All errors Displays the last 96 errors of the heat pump operation which have occurred since the commissioning of the heat pump Return Exits the displaying of the heat pump errors Viewing the List of New Errors Use the procedure described in the beginning of this chapter on page 51 to open the menu for displaying the new errors If no error has occurred the display shows New errors No errors If an error was detected the display shows New errors yy mm dd hh mm xx The bottom line contains from left to right the date and time when the error was detected and its sequential number representing its position i
8. Reset From Resets the registers of heat produced and electricity consumed register in the time interval after their the last reset Return Exits the heat pump statistics menu Compressor total time This menu allows to view the total running time in hours of the compressor since the heat pump was made 54 Heat pump operation User level v 1 04 Defrosting total time This menu allows to view the total time in hours of defrosting the evaporator since the heat pump was made Bivalence total time This menu allows to view the total running time in hours when the auxiliary heater was used together with the heat pump compressor Emergency total time This menu allows to view the total running time in hours in Emergency mode since the heat pump was made Compressor starts count This menu allows to view the total number of compressor starts since the heat pump was made 4 way valve switches count This menu allows to view the total number of 4 way valve switchings since the heat pump was made Total heat produced This menu allows to view the total heat in gigajoules GJ produced by the heat pump since the heat pump was made Total power consumed This menu allows to view the total electricity in kW consumed by the heat pump since the heat pump was made Heat produced since the last reset of registers This menu allows to view the heat in gigajoules GJ produced by the heat pump since the last res
9. Setting the outdoor temperature below which the auxiliary heater start temp can be used to heat the water Bivalence Setting the outdoor temperature under which the auxiliary heater stop temp can t be used to heat the water Bivalence Setting the time interval after which the auxiliary heater will be delay used if the heat pump power is not sufficient Return Exits the bivalence setting Enabling the Auxiliary Heating of the Water This menu allows to set the outdoor temperature below which the auxiliary heater can be used to heat the water When the status line is displayed press the confirmation button to enter the main menu and use the procedure described in chapter 7 1 4 on page 39 to open the Bivalence settings menu After opening this menu its first option is displayed Bivalence settings Bivalence start temp 39 Heat pump operation User level v 1 04 After opening this menu display shows Bivalence start temp XX X Use the dial knob to set the required temperature in the range from 30 0 C to 30 0 C After confirmation the prompt appears Save Y N xx xN Press the confirmation button to save the settings The confirmation message Saved OK briefly appears and then the display returns one level back Bivalence settings Bivalence start temp Use the dial knob and the confirmation button to select and set the other bivalence settings or you can sel
10. After setting and checking all parameters on the line press the confirmation button for a longer time to save all values Prompt Save Y N appears and after confirmation the message Saved OK briefly appears Menus for parameters setting are divided into several levels according to their influence on the heat pump performance Common settings can be freely accessible or can be protected by an optional user password Settings with a decisive influence on the heat pump performance where the improper setup would cause a malfunction are located on the service level of the menu and they can be changed only after entering a password The use of password is compulsory on the service level and this password can not be changed The most important settings are located on the manufacturing level that is only accessible to the heat pump manufacturer Heat pump operation User level v 1 04 Heat Pump Service Settings Basic 1st level 2nd level 3rd level 4th level Page menu of Manual Heating page 8 Cooling page 10 Defrost page 10 Comfort page 11 Setup Parameter Heating DHW min reserve page 15 user settings settings Temp corr Current register page 16 password program Daily page 17 Weekly page 21 By Date page 24 Return Equitherm Equitherm point 1A 2D page 26 curve Return Runtime priorities pa
11. Setting the Backlight of the Heat Pump Display This menu allows to adjust the level of the backlight When the status line is displayed press the confirmation button to enter the main menu and use the procedure described in chapter 7 2 2 on page 43 to open the Display settings menu After opening this menu its first option is displayed Terminal settings Backlight set After opening this menu the display shows Backlight set Pt The number of characters m 1 to 16 indicates the set intensity of the display backlight Use the dial knob to set the intensity and press shortly the confirmation button to save it Display returns one level back Terminal settings Backlight set Use the dial knob to select and set the other parameters of the display settings or you can select and confirm the Return option repeatedly to exit the heat pump settings and return to the default state 43 Heat pump operation User level v 1 04 Setting the Contrast of the Heat Pump Display This menu allows to adjust the contrast of the heat pump display When the status line is displayed press the confirmation button to enter the main menu and use the procedure described in chapter 7 2 2 on page 43 to open the Display settings menu After opening this menu use the dial knob to select the Contrast set option on the bottom line Terminal settings Contrast set After opening this menu the display
12. Setting the parameters needed for the operation of the heat settings pump Terminal Setting the time and parameters for the heat pump display settings Info Displaying information about settings and operation of the heat pump Connection Setting the parameters for connecting the heat pump to LAN settings WLAN networks when using the GSM module it is also possible to connect to the GSM network User password Enabling disabling the user password and setting the user password Service settings The service settings of the heat pump protected by the service password Return End of the heat pump setting and exit from the menu 13 Heat pump operation User level v 1 04 7 1 Parameter Settings This menu allows to set the parameters needed for the operation of the heat pump When the status line is displayed press the confirmation button to enter the main menu and use the dial knob to select the Setup option Menu Setup After opening this menu Setup moves to the top line of the display and the bottom line shows the Parameter settings Setup Parameter settings After opening this menu Parameter settings moves to the top line of the display and the display shows Parameter settings Heating settings Using the dial knob and the confirmation button you can select and open following options for setting parameters of the heat pump Heating Setting the priorities a
13. When the status line is displayed press the confirmation button to enter the main menu and use the procedure described in chapter 7 1 2 on page 28 to open the Temperature settings menu After opening this menu use the dial knob to select the Pool stop temp option Temperature settings Pool stop temp After opening this menu display shows Pool stop temp XX X Use the dial knob to set the required temperature in the range from 5 0 C to 35 0 C After confirmation the prompt appears Save Y N XX X Press the confirmation button to save the settings The confirmation message Saved OK briefly appears and then the display returns one level back Temperature settings Pool stop temp Use the dial knob and the confirmation button to select and set the other temperatures or you can select and confirm the Return option repeatedly to exit the settings and return to the default state Setting the Temperature Difference for Connecting Solar Heating System to HP This menu allows to set the required difference between temperature of the media in the solar heating system and the temperature of the water in the tank to use the solar heating system for heating water in the heat pump tank When the status line is displayed press the confirmation button to enter the main menu and use the procedure described in chapter 7 1 2 on page 28 to open the Temperature settings menu After opening this m
14. the displayed temperature is 60 C 63 Heat pump operation User level v 1 04 Fig 6 Heat pump menu 64 Heat pump operation User level v 1 04 9 Contents Heat Pump Control 1 1 Heat Pump Control Board 1 2 Heat Pump Control Panel Heat Pump Main Menu Heating 3 1 Heating in Normal Mode 3 2 Emergency Heating Cooling Manual Defrosting of the Heat Pump Evaporator Comfort 6 1 Quick Temperature Adjustment in the Equitherm Control Mode 6 2 Quick Temperature Adjustment in the Reference Room Mode Heat Pump Setting 7 1 Parameter Settings 7 1 1 Heating Settings 7 1 2 Setting the Temperature Parameters of the Heat Pump 7 1 3 Setting Heat Pump Tariffs 7 1 4 Bivalence Settings 7 2 Terminal Settings 7 2 1 Setting the Real Time Clock 7 2 2 Display settings 7 2 3 Setting the Display Mapping 7 2 4 Setting the Language Version of the Heat Pump Control Program 7 3 Information about the Configuration and Operation of HP 7 3 1 Mains Voltage 7 3 2 High Tariff Duration 7 3 3 Configuration and Program Version of the Heat Pump 7 3 4 List of the Heat Pump Errors 7 3 5 Statistics of the Heat Pump Operation 7 4 Settings the Connection to LAN WLAN and GSM Network 7 4 1 Settings the Connection of the Heat Pump to LAN WLAN 7 4 2 Settings the Connection of the Heat Pump to GSM network 7 5 Setting the User Password 8 Summary of hea
15. AT 2 4 CT 6 8 The top line of the display shows the status line Individual symbols for the compressor character C the evaporator fan character F and the circulation pump character P are followed by rotating symbols dashes In the cooling mode the dash associated with the compressor rotates counterclockwise and the other dashes rotate in clockwise direction Indication Cool is displayed only until the compressor starts up then it is replaced by symbol of the cooled circuit accompanied by a star or symbol for heating the DHW or pool The bottom line of the display shows the selected pair of temperatures you can shift the displayed parameters in both directions using the dial knob The position of the temperatures on the display lines can be set in the Display mapping menu Cooling Return If the Cooling menu is opened when the heat pump is running in the cooling mode the display shows the option to stop the pump Cooling Stop After confirming the Stop option the heat pump stops according to the pre programmed algorithms and the display returns to the default state During the stopping of the pump only the Setup and Comfort menus are accessible no heat pump function can be set until the complete stop of the unit 5 Manual Defrosting of the Heat Pump Evaporator Due to the low temperature of the expanding refrigerant in the evaporator a frost is gradually build up on the evaporator fin wh
16. C to 4 9 C Example The first made correction for the equitherm control mode Edit EQ1 EQ2 00 05 30 2 0 4 0 can be stored to the current register by a long press of the confirmation button Edit Append Press the confirmation button The message Saved OK briefly appears and then the display returns one level back Daily View The current register now contains the first daily correction with number 01 In this example this means that from 05 30 the heating water temperature EQ1 in the first heating circuit TE1 is decreased by 2 0 C and heating water temperature EQ2 in the second heating circuit TE2 is decreased by 4 0 C To make another daily correction press the confirmation button The display shows the option to view the new correction with the set time and the temperature shifts from the previous correction The example applies again for the equitherm control if the heating control according to the temperature in the reference room is selected only one temperature shift value dT appears instead of two temperatures EQ1 and EQ2 View EQ1 EQ2 01 05 30 2 0 4 0 Press the confirmation button the display changes from View to Edit Edit EQ1 EQ2 01 05 30 2 0 4 0 If the current register contains any correction you can use the dial knob to also select the Delete option in addition to the Edit and Return options The Delete option is used to deleted the displayed co
17. both longer sides are terminals for connecting input output wires Outputs dedicated to switching mains voltage 230V power input terminals 3x400V 50Hz for powering the board and a terminal for a price tariff signal from an electricity meter are located on one side of the control board signal inputs outputs are on the other side of the board The connection with the external heat pump circuits is made through three separate terminal blocks which are also located under the top cover of the heat pump no wires are connected to the control board when mounting the heat pump at the user site B 5 a a SS 1e ana Fig 2 Heat pump control board Heat pump operation User level v 1 04 1 2 Heat Pump Control Panel The control board is equipped with a simple control panel located on the plastic cover of the heat pump indoor unit The control panel contains a backlit alphanumeric display with 2 x 20 characters to select menu items and to set them up a bi directional dial knob with confirmation button in its centre is used The control panel is mounted on a support plate of stainless steel coated with a cover plate The connection between the control panel and the heat pump control board is established via a flat cable 65 SINCLAIR Fig 3 Heat pump control panel After turning on the heat pump performs a self test and a initial message is displayed on the control panel display and a red LED lights during this test If you have al
18. dial knob and the confirmation button to select and set the other information about the heat pump configuration or you can select and confirm the Return option repeatedly to exit the settings and return to the default state 50 Heat pump operation User level v 1 04 Displaying the Control Board Program Versions This menu allows to display the program versions of each processor on the control board When the status line is displayed press the confirmation button to enter the main menu and use the procedure described in chapter 7 3 3 on page 50 to open the HW SW configuration menu After opening this menu use the dial knob to select the option for displaying the program versions HW SW configuration SW version After opening this menu the display bottom line shows four version numbers SW version a aa b bb c cc d dd Press shortly the confirmation button to return one level back Use the dial knob and the confirmation button to select and set the other information about the heat pump configuration or you can select and confirm the Return option repeatedly to exit the settings and return to the default state Displaying the Serial Number of the Heat Pump Control Board This menu allows to display the serial number of the heat pump control board When the status line is displayed press the confirmation button to enter the main menu and use the procedure described in chapter 7 3 3 on page 50 to open the
19. knob to select and set the other parameters of the display settings or you can select and confirm the Return option repeatedly to exit the heat pump settings and return to the default state 44 Heat pump operation User level v 1 04 7 2 3 Setting the Display Mapping This menu allows to set the order of the temperatures to be displayed on the first 16 positions i e on 8 lines of the display These temperatures are followed by 10 operation parameters which are displayed in the fixed order When the status line is displayed press the confirmation button to enter the main menu and use the dial knob to select the Setup option Menu Setup After opening this menu Setup moves to the top line of the display Use the dial knob to select the Terminal settins option on the bottom line Setup Terminal settings After opening this menu Terminal settings moves to the top line of the display Use the dial knob to select the Display mapping option on the bottom line Terminal settings Display mapping After opening this menu the display shows Display mapping Mapping set 0 Txl The cursor is blinking on the number that indicates the position to display the temperature After pressing the confirmation button the cursor moves to the label acronym of the temperature to be displayed on the position 0 Use thedial knob to select the required temperature for example the ambient o
20. line Setup Connection settings After opening this menu Connection settings moves to the top line of the display and the display shows Connection settings LAN WAN settings Use the dial knob to select the required option on the bottom line LAN WAN settings This menu allows to set parameters for connecting the heat pump to the LAN WLAN network GSM settings This menu allows to set parameters for connecting the heat pump to the GSM network it is available only when the GSM module is installed Return Exits this menu 7 4 1 Settings the Connection of the Heat Pump to LAN WLAN This menu allows you to set parameters for connecting the heat pump to the LAN WLAN and GSM network When the status line is displayed press the confirmation button to enter the main menu Use the dial knob to select the Setup option on the bottom line Menu Setup After opening this menu Setup moves to the top line of the display Use the dial knob to select the Connection settings option on the bottom line Setup Connection settings After opening this menu Connection settings moves to the top line of the display and the display shows Connection settings LAN WAN settings After opening this menu if the LAN module is installed and functioning properly LAN WAN settings moves to the top line of the display and the display shows LAN WAN settings Assigned IP address
21. menu Use the dial knob to select the Setup option on the bottom line Menu Setup After opening this menu Setup moves to the top line of the display Use the dial knob to select the Connection settings option on the bottom line Setup Connection settings After opening this menu Connection settings moves to the top line of the display Use the dial knob to select the GSM settings option on the bottom line Connection settings GSM settings 57 Heat pump operation User level v 1 04 After opening this menu if the GSM module is installed and functioning properly GSM settings moves to the top line of the display and the display shows GSM settings Phone numbers If the GSM module is not installed or is not functioning properly the GSM settings menu can not be opened After opening the GSM settings menu you can use the dial knob and the confirmation button to select and edit required parameters to connect the heat pump to GSM network Phone numbers Setting and editing phone numbers stored in the GSM module memory GSM switch off Setting the time delay between power failure and switching delay off the GSM module Return Exits connection settings Setting and editing the phone numbers in the GSM module GSM module memory can store up to 16 phone numbers at which the heat pump will send SMS message on the request or in case of power failure From these so called
22. opening this menu HW SW configuration moves to the top line of the display and the display shows HW SW configuration HW configuration Using the dial knob and the confirmation button you can select and view the following HW SW information about the heat pump HW Displaying the installed expansion modules of the heat pump configuration SW version Displaying the program versions of each processor on the control board Serial number Displaying the six digit serial number of the heat pump control board Return Exits the HW SW configuration menu Displaying the Installed Expansion Modules of the Heat Pump This menu allows to display the extending LAN and GSM modules which are installed on the heat pump control board When the status line is displayed press the confirmation button to enter the main menu and use the procedure described in chapter 7 3 3 on page 50 to open the HW SW configuration menu After opening this menu its first option is displayed HW SW configuration HW configuration After opening this menu the display shows the LAN a GSM labels which are followed by Y YES if the corresponding module is installed and functioning properly or N NO if the module is not installed or is not functioning properly Example the control board with only LAN module installed HW configuration LAN Y GSM N Press shortly the confirmation button to return one level back Use the
23. pump is unable to achieve the required temperature of the water in the tank within the set time at low outdoor temperatures auxiliary electric heater is switched on and heats the water until the required temperature is reached When the status line is displayed press the confirmation button to enter the main menu and use the procedure described in chapter 7 1 4 on page 39 to open the Tariff settings menu 40 Heat pump operation User level v 1 04 After opening this menu use the dial knob to select the Bivalence delay option Bivalence settings Bivalence delay After opening this menu display shows Bivalence delay XXX Use the dial knob to set the required time in the range from 0 to 250 minutes Press the confirmation button to confirm the set value and a prompt appears Save Y N XXX Press the confirmation button to save the settings The confirmation message Saved OK briefly appears and then the display returns one level back Bivalence settings Bivalence delay Use the dial knob and the confirmation button to select and set the other bivalence settings or you can select and confirm the Return option repeatedly to exit the settings and return to the default state 7 2 Terminal Settings This menu allows to set the real time clock display settings display mapping and language version of the heat pump program When the status line is displayed press the confirma
24. pump running is too short when the limit states are reached or at the high tariff of the supplied electricity if this condition is activated When the status line is displayed press the confirmation button to enter the main menu and use the procedure described in chapter 7 1 2 on page 28 to open the Temperature settings menu After opening this menu use the dial knob to select the Pool start temp option Temperature settings Pool start temp After opening this menu display shows Pool start temp XX X Use the dial knob to set the required temperature in the range from 5 0 C to 35 0 C After confirmation the prompt appears Save Y N XX X Press the confirmation button to save the settings The confirmation message Saved OK briefly appears and then the display returns one level back Temperature settings Pool start temp Use the dial knob and the confirmation button to select and set the other temperatures or you can select and confirm the Return option repeatedly to exit the settings and return to the default state 32 Heat pump operation User level v 1 04 Setting the Stop Temperature for Heating the Pool This menu allows to set the maximum temperature of the water in the pool When the temperature reaches the set value heating is stopped and if there is no other reason to run the heat pump DHW heating HeW heating evaporator defrosting it is turned off
25. restored GSM module is connected and logged to the network When heat pump stops for another reason than the power outage for example repeated exceeding the limit parameters SMS messages are sent to the selected phone numbers immediately after stopping the pump and GSM module remains connected to the network When the status line is displayed press the confirmation button to enter the main menu and use the procedure described in chapter 7 4 2 on page 57 to open the GSM settings menu After opening this menu use the dial knob to select the GSM switch off delay option GSM settings GSM switch off delay After opening this menu the display shows GSM switch off delay XXX Use the dial knob to set the delay in the range from 0 to 250 minutes Press the confirmation button to save the set value Save Y N XXX Press the confirmation button to save the settings A confirmation message Saved OK briefly appears and then the display returns one level back GSM settings GSM switch off delay Use the dial knob to select and set the other parameters for connection to the GSM network or you can select and confirm the Return option repeatedly to exit the heat pump settings and return to the default state 59 Heat pump operation User level v 1 04 7 5 Setting the User Password The parameter settings are divided into three levels according to their influence on the heat pump perf
26. shows Weekly View After opening this menu if the equitherm control mode is selected and the current register is empty the display shows View EQ1 EQ2 00Mo LD Heat pump operation User level v 1 04 In the heating mode according to the temperature in the reference room only one value of the temperature shift dT is diplayed instead of two temperatures EQ1 and EQ2 Number 00 means that no weekly correction is stored in the current register Press the confirmation button to edit the first weekly temperature correction Edit EQ EQ2 00Mo Press the confirmation button to select the day when the first correction should begin Use the dial knob to select the required day Press the confirmation button and use the same procedure to set hours and minutes when the first correction should begin In the equitherm heating mode you can set the heated water temperature correction in the first heating circuit Use the dial knob to set the correction in the range of 9 9 C to 9 9 C Press the confirmation button and you can set the heated water temperature correction in the second heating circuit In the heating mode according to the temperature in the reference room you can set correction dT in the range of 4 9 C to 4 9 C Example The first made correction for the equitherm control mode Edit EQ1 EQ2 00Mo 06 00 2 0 4 0 can be stored by a long press of t
27. the Terminal settings option on the bottom line Setup Terminal settings After opening this menu Terminal settings moves to the top line of the display and the display shows Terminal settings Time settings After confirmation the prompt appears Time settings 12 00 00 Blinking cursor on the Hour position indicates the sequence for setting the clock Use the dial knob to set the hours and press shortly the confirmation button to set the minutes Set the minutes and press shortly the confirmation button to set the seconds Check whether the set time is correct and press the confirmation button for a longer time to exit the time setting mode The display will show Save Y N hh mm ss and the cursor is blinking on the Y YES position Press the confirmation button to save the settings The confirmation message Saved OK briefly appears and then the display returns one level back Date settings 01 01 00 Use the similar procedure to set the required day month and year Press the confirmation button for a longer time to exit the date setting mode The display will show Save Y N dd mm yy Press the confirmation button to save the date The confirmation message Date settings Saved OK and then the display returns one level back in the menu Terminal settings Time settings Use the dial knob and the confirmation button to sele
28. the low tariff If the outdoor temperature drops below the set limit the pool water is heated as necessary regardless of the current tariff When the outdoor temperature increases effect of the tariff is enabled only when the outside temperature exceeds the limit that enables the effect of the tariff see the next chapter The temperature limit that enables the effect of the tariff must be set about 2C higher than the temperature limit that disables the effect of the tariff hysteresis When the status line is displayed press the confirmation button to enter the main menu and use the procedure described in chapter 7 1 3 on page 34 to open the Tariff settings menu After opening this menu use the dial knob to select the option Pool tariff stop Tariff settings Pool tariff stop After opening this menu display shows Pool tariff stop XX X Use the dial knob to set the required temperature in the range from 30 0 C to 30 0 C After confirmation the prompt appears Save Y N XX X Press the confirmation button to save the settings The confirmation message Saved OK briefly appears and then the display returns one level back Tariff settings Pool tariff stop Use the dial knob and the confirmation button to select and set the other tariffs or you can select and confirm the Return option repeatedly to exit the settings and return to the default state Enabling the Effect of the Tariff on H
29. the point A of the 1st equitherm curve Equitherm curve 1 Equitherm point A The cursor is blinking on the position of point A Press the confirmation button Setting of the point A of the 1st equitherm curve appears Equitherm point 1 A Tai XXX X Twa XX X The cursor is blinking on the air temperature Tai Use the dial knob to set the air temperature for the first point The points are arranged in a fixed order The point with the lowest temperature is the first the temperature of the next points is gradually increased up to the positive values After setting the air temperature for the fist point press shortly the confirmation button to set the water temperature for the first point Set the temperature in a similar way and press the confirmation button for a longer time to exit setup of the first point of the equitherm curve You can set air temperature in the range of 30 0 C to 30 0 C water temperature in the range of 5 C to 60 C The display shows Save Y N Tai XXX X Twa XX X 26 Heat pump operation User level v 1 04 Save the settings The confirmation message Saved OK briefly appears and then the display returns one level back Equitherm curve 1 Equitherm point A Use the dial knob and the confirmation button to set the other points of the first and then the second equitherm curve After setting all the points of both curves use the Return option to leav
30. 4 Setting the Stop Temperature for Cooling the Hew This menu allows to set the minimum temperature of the heating water in the cooling mode When the temperature is below the set value the heat pump stops to cool HeW When the status line is displayed press the confirmation button to enter the main menu and use the procedure described in chapter 7 1 2 on page 28 to open the Temperature settings menu After opening this menu use the dial knob to select the Cooling stop temp option Temperature settings Cooling stop temp After opening this menu display shows Cooling stop temp XX X Use the dial knob to set the required temperature in the range from 5 0 C to 35 0 C After confirmation the prompt appears Save Y N XX X Press the confirmation button to save the settings The confirmation message Saved OK briefly appears and then the display returns one level back Temperature settings Cooling stop temp Use the dial knob and the confirmation button to select and set the other temperatures or you can select and confirm the Return option repeatedly to exit the settings and return to the default state Setting the Start Temperature for Heating the Pool This menu allows to set the minimum temperature of the water in the pool When the temperature drops below the set value the heat pump starts to heat The pump start may be delayed for example if the time since the last
31. CONTROL AND OPERATION MANUAL lt ERM SPLIT AIR TO WATER HEAT PUMPS SHP 140IRC SHP 140ERC SHP 180IRC SHP 180ERC AU HEAT PUMPS Heat pump operation User level v 1 04 1 Heat Pump Control Heat pump control circuits are located under the plastic cover in the upper part of the indoor unit cabinet A galvanized metal sheet carries a printed circuit board with control electronics a DIN35 mounting rail with electromechanical contactor for heat pump compressor an electromechanical contactor for auxiliary heater and a block for smooth start of heat pump compressor motor There are also auxiliary relays with 230V 10A closing contacts for switching an evaporator fan motor and a circulation pump motor Moreover there are terminals for power supply 3x400V 50Hz for signals from outdoor blocks of the heat pump and terminals for control signals and power supply for these blocks To set up and control the heat pump performance the control board is equipped with a simple control panel with a display and a dial knob located on the plastic cover of the indoor unit heat pump Location of the control circuits inside the heat pump indoor unit is shown in Fig 1 auxiliary relays power supply 3x400V 50 Hz CI smooth start of the compressor contactor for compressor contactor for auxiliary heater auxiliary terminals Fig 1 Location of the control circuits inside the heat pump indoor unit Heat pump operation User lev
32. HW SW configuration menu After opening this menu use the dial knob to select the option for displaying the serial number HW SW configuration Serial number After opening this menu the display bottom line shows six digit serial number of the heat pump control board Serial number 123456 Press shortly the confirmation button to return one level back Use the dial knob and the confirmation button to select and set the other information about the heat pump configuration or you can select and confirm the Return option repeatedly to exit the settings and return to the default state 7 3 4 List of the Heat Pump Errors This menu is designed to display errors that occurred during the heat pump operation When an error occurs the heat pump stops and after 5 minutes it automatically tries to restores the previous operation mode If the error persists the heat pump repeats this two more times with increasing intervals 10 and 15 minutes If even the third attempt to restore the operation fails the pump stops and waits for operator intervention When the status line is displayed press the confirmation button to enter the main menu If an error is detected after entering the main menu an error message is displayed together with up to five errors and their specifications See the Error list on page 61 for details If the heat pump is in an error state only Setup and Comfor menus are accessible Menu HP error PW
33. Heating is controlled using the equitherm control the Heating settings menu allows to set the equitherm curves for two heating circuits Eqt ctrl Ref room Heating is controlled using the equitherm control that is corrected according to temperature in the reference room Reference temp Setting the desired temperature in the reference room allowed range is from 15 0 to 30 0 C Emergency mode Activation of the emergency mode when selected the heat pump will heat in emergency mode Return Exits the heating mode setting After confirmation of the selected mode the prompt appears Equitherm control No You can use the dial knob to switch from No to Yes for the selected mode After confirmation the prompt appears Save Y N No Press the confirmation button to save the settings The confirmation message Saved OK briefly appears and then the display returns one level back Heating mode Equitherm control Use the same procedure when selecting the Eqt ctrl Ref room or Emergency mode Emergency mode has an AUTO option besides the YES NO options AUTO option allows the heat pump to automatically switch to the emergency mode when an error occurs during operation Use the dial knob and the confirmation button to select and set other parameters of the heating or you can select and confirm the Return option repeatedly to exit the settings and return to the default state 7 1 2 Setting t
34. Heating menu that allows you to run the heat pump In the Emergency mode the Cooling and Defrost menus are not accessible Menu Heating After opening this menu Heating moves to the top line of the display and if the pump is switched off the display shows Heating Start After confirming the Start option the control board performs a check of the parameters and then starts the heat pump in the emergency mode E F P TEL E DO 10 52 AT 2 4 CT 6 8 The top line of the display shows the status line Individual symbols for the emergency mode E the fan F and the circulation pump P are followed by symbols dashes which rotate in clockwise direction when the related parts run normally The following indication TE1 determines the heated circuit the character E means the Equitherm control and DO means the active Daily temperature correction according to the register 0 The bottom line of the display shows the selected pair of temperatures you can shift the displayed parameters in both directions using the dial knob The position of the temperatures on the display lines can be set in the Display mapping menu The Heating menu can be left without starting up the heat pump Heating Return If the menu Heating is opened when the heat pump is running the display shows the option to stop the pump Heating Stop After confirming the Stop option the heat pump stops accordi
35. Solar stop delta After opening this menu display shows Solar stop delta XX X Use the dial knob to set the required temperature difference in the range from 0 C to 25 0 C the typical value is about 5 0 C After confirmation the prompt appears Save Y N XX X Press the confirmation button to save the settings The confirmation message Saved OK briefly appears and then the display returns one level back Temperature settings Solar stop delta Use the dial knob and the confirmation button to select and set the other temperatures or you can select and confirm the Return option repeatedly to exit the settings and return to the default state 7 1 3 Setting Heat Pump Tariffs This menu allows to set the effect of low and high tariffs for electricity on the heat pump operation For example at higher outdoor temperatures you can use electricity to heating the DHW HeW and water in the pool at the low tariff only or when the outdoor temperature is below the set limit the heat pump can operate regardless of the current tariff Temperature limits for tariffs can be set individually for each heating circuit When the status line is displayed press the confirmation button to enter the main menu and use the dial knob to select the Setup option on the bottom line Menu Setup After opening this menu Setup moves to the top line of the display and the bottom line shows the Parameter s
36. Status in the binary format 0 0 0 0 0 0 0 1 Bit weights in the binary format 8 4 2 1 8 4 2 1 Significance of each bit TU LU TU LU TU LU pha tariff se seq Phase terminal no T 2 S 3 R 4 T U means that the voltage of the corresponding phase is higher than the allowed tolerances tolerance i U means that the voltage of the corresponding phase is lower or zero Example status 41 means the missing phase T Status on the display 4 1 hexadecimal Status in the binary format 0 1 0 0 0 0 0 1 Bit weights in the binary format 8 4 2 1 8 4 2 1 Significance of each bit TU lLU TU LU TU LU pha tariff se seq Phase terminal no T 2 S 3 R 4 Press shortly the confirmation button to leave the Mains voltage menu Display returns one level back Use the dial knob and the confirmation button to select and set the other options of the Info menu or you can select and confirm the Return option repeatedly to exit the settings and return to the default state 7 3 2 High Tariff Duration This menu allows to view the duration of the high tariff for electricity Their number and distribution during the day depends on the supplier of electricity and the agreed rate When the status line is displayed press the confirmation button to enter the main menu and use the dial knob to select the Setup option Menu Setup After opening this menu Setup moves
37. arts the defrosting of the heat pump evaporator C F P TE1 E DO 10 52 AT 2 4 CT 6 8 Individual symbols for the compressor character C the evaporator fan character F and the circulation pump character P are followed by rotating symbols dashes In the defrosting mode the dash associated with the compressor rotates counterclockwise and the other dashes rotate in clockwise direction The defrosting of the heat pump evaporator is terminated automatically when the conditions for its termination are met or you can terminate it manually During the defrosting operation when the Defrosting menu is opened the display shows Defrost Stop After confirming the Stop option the heat pump stops according to the pre programmed algorithms and the display returns to the default state During the stopping of the pump only the Setup and Comfort menus are accessible no heat pump function can be set until the complete stop of the unit CFP OFF 10 52 AT 2 4 CT 6 8 To exit the Defrost menu without making any defrosting operation use the Return option 6 Comfort This menu is designed for a quick correction of the temperature in the heated building without changing the heat pump settings Depending on the selected mode of the operation you can adjust the heating water temperature in the equiterm control mode or you can adjust directly the required air temperature in the reference room in the reference r
38. at pump Return Exits connection settings With dynamic assignment of IP address subnet mask gateway and DNS server you must use the dial knob to select the Preset IP address option confirm it and use dial knob to adjust the zero address After setting up the first part of the IP address to zero shortly press the confirmation button to set the next part of the IP address Set all parts of the IP addresses in asimilar way and the press the confirmation button for a longer time to save the zero IP address to memory After confirming the query Save the address is saved and and the display returns one level back If the zero IP address is set the heat pump IP address subnet mask gateway and DNS address is assigned automatically by DHCP server dynamic address allocation In the opposite case i e when the non zero IP address is set it is necessary to set subnet mask gateway and DNS address manually static address allocation If the FTPS address is set to non zero value it is possible to control the heat pump only using the remote access through the Internet it isn t possible to control heat pump from the local network from the local WEB server It is possible only when the FTPS address is set to zero 7 4 2 Settings the Connection of the Heat Pump to GSM network This menu allows you to set parameters for connecting the heat pump to the GSM network When the status line is displayed press the confirmation button to enter the main
39. ated and heating will be controlled according to the selected contro mode without using the daily temperature correction 20 Heat pump operation User level v 1 04 Weekly Heating Temperature Corrections This menu allows you to set up to 56 time corrections of water temperature in one or two heating circuits against the temperature determined by the control algorithms within one week All set corrections are entered into the pre selected current temperature correction register The temperature corrections of the heating water temperature used in the equitherm control mode and the temperature corrections of the air temperature used in the heating control mode according to the reference room are stored separately in two sets of registers which are switched automatically when the heating mode is changed This means that all the operations described here will be carried out only in one set of registers corresponding to the currently used control mode When the status line is displayed press the confirmation button to enter the main menu and use the procedure described in chapter 7 1 1 on page 14 to open the Heating settings menu Use the dial knob to select the option for temperature correction programming Heating settings Temp corr program After opening this menu use the dial knob to select the option for weekly temperature correction programming Temp corr program Weekly After opening this menu W
40. ation the prompt appears Save Y N XX X Press the confirmation button to save the settings The confirmation message Saved OK briefly appears and then the display returns one level back Tariff settings DHW tariff stop Use the dial knob and the confirmation button to select and set the other tariffs or you can select and confirm the Return option repeatedly to exit the settings and return to the default state Enabling the Effect of the Tariff on Heating the DHW by HP This menu allows to set the outdoor temperature limit under which the heat pump heats the domestic hot water according to the current tariff for electricity If the outdoor temperature drops below the limit that disables the effect of the tariff on heating the DHW see the previous chapter the heat pump heats the domestic hot water regardless of the tariff If the outdoor temperature is higher than the set limit that enables the effect of the tariff the DHW is heated only at the low tariff The temperature limit that enables the effect of the tariff must be set about 2 C higher than the temperature limit that disables the effect of the tariff When the status line is displayed press the confirmation button to enter the main menu and use the procedure described in chapter 7 1 3 on page 34 to open the Tariff settings menu After opening this menu use the dial knob to select the DHW tariff start option Tariff settings DHW tariff start Af
41. authorized numbers you can also switch the heat pump on off or request the information about its status Phone numbers must be stored in international format without the sign and 00 before the country dial Each number must consist of 12 digits Phone numbers are stored in memory at positions 0 through F If a phone number with the country dial code have less than 12 digits you must add zeros before the country dial code When the status line is displayed press the confirmation button to enter the main menu and use the procedure described in chapter 7 4 2 on page 57 to open the GSM settings menu After opening this menu its first option is displayed GSM settings Phone numbers After opening this menu Phone numbers moves to the top line of the display and if no phone number is stored in memory the display shows Phone numbers where on the first position from left is the position number to save the phone number followed by 12 digit phone number in international format without the sign and 00 before the country dial ode If there are some phone numbers already stored in certain positions you can use the dial knob to select the required position to store the phone number and confirm it The first option of the menu appears You can use the dial knob to choose the required operation with the phone number in the selected position You can create new number edit or delete the existing number or leave sel
42. ct and set the other terminal settings or you can select and confirm the Return option repeatedly to exit the settings and return to the default state 42 Heat pump operation User level v 1 04 7 2 2 Display settings This menu allows to set the backlight contrast and time interval to restore the default display if no operator action is taken When the status line is displayed press the confirmation button to enter the main menu and use the dial knob to select the Setup option Menu Setup After opening this menu Setup moves to the top line of the display Use the dial knob to select the Terminal settins option on the bottom line Setup Terminal settings After opening this menu Terminal settings moves to the top line of the display Use the dial knob to select the Display settings option on the bottom line Terminal settings Display settings After opening this menu Display settings moves to the top line of the display and the display shows Display settings Backlight set Using the dial knob and the confirmation button you can select and open the following options for setting the heat pump display Backlight set Setting the backlight of the heat pump display Contrast set Setting the contrast of the heat pump display Idle time Setting the time interval to restore the default display if no operator action is taken Return Exits the display settings
43. dividual registers one for equitherm regulation and one for regulation according to the reference room temperature These registers sets are switched automatically when the heating mode is changed The Comfort menu in the reference room mode looks like Comfort Ref T correc x x Use the dial knobe to set the shift of air temperature in the reference room in the range from 4 9 to 4 9 C Confirm the settings by long press of the confirmation button The display shows Save Y N Ref T correc X X and the cursor is blinking on the Y YES position Press the confirmation button to save the settings The confirmation message Saved OK briefly appears and then the display returns one level back in the menu By shifting the temperature in the Comfort menu the required temperature in the reference room is adjusted by the set value This shift of the temperature is valid until it is reseted in the Comfort menu or until reaching such date and time when the shift of the air temperature if the reference room set in the Comfort menu is cancelled 12 Heat pump operation User level v 1 04 7 Heat Pump Setting This menu is designed to set the parameters required for the proper operation of the heat pump Procedure to open this menu depends on whether the user password is enabled or not By default the user password is disabled user can enable using the password and set it If the user password is disabled you can d
44. e main menu and use the procedure described in chapter 7 1 3 on page 34 to open the Tariff settings menu 36 Heat pump operation User level v 1 04 After opening this menu use the dial knob to select the HeW tariff stop option Tariff settings HeW tariff stop After opening this menu display shows HeW tariff stop XX X Use the dial knob to set the required temperature in the range from 30 0 C to 30 0 C After confirmation the prompt appears Save Y N XX X Press the confirmation button to save the settings The confirmation message Saved OK briefly appears and then the display returns one level back Tariff settings HeW tariff stop Use the dial knob and the confirmation button to select and set the other tariffs or you can select and confirm the Return option repeatedly to exit the settings and return to the default state Enabling the Effect of the Tariff on Heating the HeW by HP This menu allows to set the outdoor temperature limit under which the heat pump heats the heating water according to the current tariff for electricity If the outdoor temperature drops below the limit that disables the effect of the tariff on heating the HeW see the previous chapter the heat pump heats the domestic hot water regardless of the tariff If the outdoor temperature is higher than the set limit that enables the effect of the tariff the HeW is heated only at the low tar
45. e the menu for setting the equitherm curve The display returns one level back Heating settings Equitherm curve Use the dial knob and the confirmation button to select and set the other heating parameters or you can select and confirm the Return option repeatedly to exit the settings and return to the default state Setting Priorities for Heating Circuits This menu allows to set heating priorities of each heating circuit Selection of heating circuits and their order on the display is specified by the service settings according to the heat pump configuration When the status line is displayed press the confirmation button to enter the main menu and use the procedure described in chapter 7 1 1 on page 14 to open the Heating settings menu Use the dial knob to select the option for setting priorities of the heat pump operation Heating settings Runtime priorities After opening this menu the display shows the heating circuits according to the heat pump configuration For example when using one or two heating circuits the domestic hot water heating and the pool water heating the display shows Runtime priorities TE1 x DHW x Pool x Character x represents the numbers 0 3 that specify the priority of each heating circuit Use the dial knob to set the priority of the first heating circuit press shortly the confirmation button to set the priority of the second circuit and in the similar way set pri
46. eW stop temp Use the dial knob and the confirmation button to select and set the other temperatures or you can select and confirm the Return option repeatedly to exit the settings and return to the default state Setting the Start Temperature for Cooling the HeW This menu allows to set the maximum temperature of the heating water in the cooling mode When the temperature is above the set value the heat pump starts to cool HeW When the status line is displayed press the confirmation button to enter the main menu and use the procedure described in chapter 7 1 2 on page 28 to open the Temperature settings menu After opening this menu use the dial knob to select the Cooling start temp option Temperature settings Cooling start temp After opening this menu display shows Cooling start temp XX X Use the dial knob to set the required temperature in the range from 5 0 C to 35 0 C After confirmation the prompt appears Save Y N XX X Press the confirmation button to save the settings The confirmation message Saved OK briefly appears and then the display returns one level back Temperature settings Cooling start temp Use the dial knob and the confirmation button to select and set the other temperatures or you can select and confirm the Return option repeatedly to exit the settings and return to the default state 31 Heat pump operation User level v 1 0
47. eat pump starts to cool HeW Setting the heating water temperature at which the heat pump temp stops to cool HeW Pool start Setting the pool water temperature at which the heat pump starts to temp heat pool water Pool stop Setting the pool water temperature at which the heat pump stops to temp heat pool water Solar start Setting the difference between the temperature of the solar heating delta system and the temperature of the water in the tank at which the solar heating system starts to heat the water in the tank Solar stop Setting the difference between the temperature of the solar heating delta system and the temperature of the water in the tank at which the solar heating system stops to heat the water in the tank Return Exits the temperature constants setting Setting the Start Temperature for Heating the DHW This menu allows to set the minimum temperature of the domestic hot water in the DHW tank When the temperature drops below the set value the control board evaluates the situation and if there are no restrictions the heat pump starts to heat DHW The pump start may be delayed for example if the time since the last pump running is too short when the limit states are reached or at the high tariff of the supplied electricity if this condition is activated In such cases the pump starts when all the relevant conditions are met When the status line is displayed press the confirmation button to enter the mai
48. eating the Pool by HP This menu allows to set the outdoor temperature limit under which the heat pump heats the pool water according to the current tariff for electricity If the outdoor temperature drops below the limit that disables the effect of the tariff on heating the pool water see the previous chapter the heat pump heats the pool water regardless of the tariff If the outdoor temperature is higher than the set limit that enables the effect of the tariff the pool water is heated only at the low tariff The temperature limit that enables the effect of the tariff must be set about 2C higher than the temperature limit that disables the effect of the tariff hysteresis When the status line is displayed press the confirmation button to enter the main menu and use the procedure described in chapter 7 1 3 on page 34 to open the Tariff settings menu After opening this menu use the dial knob to select the Pool tariff start option Tariff settings Pool tariff start After opening this menu display shows Pool tariff start XX X Use the dial knob to set the required temperature in the range from 30 0 C to 30 0 C After confirmation the prompt appears Save Y N XX X Press the confirmation button to save the settings The confirmation message Saved OK briefly appears and then the display returns one level back Tariff settings Pool tariff start 38 Heat pump operation User
49. ect and confirm the Return option repeatedly to exit the settings and return to the default state Disabling the Auxiliary Heating of the Water This menu allows to set the outdoor temperature under which the auxiliary heater can t be used to heat the water When the status line is displayed press the confirmation button to enter the main menu and use the procedure described in chapter 7 1 4 on page 39 to open the Tariff settings menu After opening this menu use the dial knob to select the Bivalence stop temp option Bivalence settings Bivalence stop temp After opening this menu display shows Bivalence stop temp XX X Use the dial knob to set the required temperature in the range from 30 0 C to 30 0 C After confirmation the prompt appears Save Y N XX X Press the confirmation button to save the settings The confirmation message Saved OK briefly appears and then the display returns one level back Bivalence settings Bivalence stop temp Use the dial knob and the confirmation button to select and set the other bivalence settings or you can select and confirm the Return option repeatedly to exit the settings and return to the default state Delayed Start of the Auxiliary Heater Bivalence Delay This menu allows to set the maximum runtime of the compressor to achieve the required temperature of the water in the tank without using the auxiliary electric heater If the heat
50. ected position using the Return option After confirming the previous option cursor is blinking on the first position of the phone number You can use thedial knob to set the first digit of the phone number in the international format Confirm the set digit by short press of the confirmation button Use the similar way to set all digits of the phone number Check the phone number and press the confirmation button for a longer time to save it Example Phone number 123456789 with the Czech prefix 420 at position number 0 Save Y N 0 420123456789 58 Heat pump operation User level v 1 04 Press the confirmation button to save the settings The confirmation message briefly appears Saved OK 0 420123456789 and then the display returns to Phone numbers settings GSM settings Phone numbers After re opening this menu the stored number is displayed on the position 0 Use can use the dial knob to select another position to enter the new phone number or delete the existing one You can store up to 16 phone number to GSM module memory Setting the Delayed Switching Off the GSM module at Power Failure GSM module supply is backed up by a Li Pol battery In case of power failure the GSM module is waiting for power restore and until the set delay time is over GSM module sends SMS messages about power failure to the selected phone numbers and disconnects from the backup battery After the power is
51. ed correction you can use the dial knob to select the View Delete Activate or Return option When you select the Delete option By Date Delete you can delete the stored temperature correction by date After confirmation of the prompt Save Y N Delete the temperature correction by date is deleted Activation of Temperature Correction by Date This option allows to activate enable the set daily temperature corrections by date to control the heating operation After confirming the Activate option By Date Activate a prompt with the default option NO appears Use the dial knob to select the YES option a confirm it Activate Yes Heat pump continues to operate and after the set time is reached the temperature is corrected by the set correction If the heat pump is in the standby state when the correction by date starts the heat pump is switched to the Heating mode the used heating mode is the same as it was in the time of activating the temperature correction by date and the heat pump starts to heat according to the specified program Deactivation of Temperature Correction by Date To disable the temperature correction by date select the Activate option in the menu for temperature correction by date Activate No After confirming the NO option the temperature correction by date is disabled and heating is controlled without using temperature correction 25 Heat pum
52. ed of running Service intervention is needed If the error is pressure at pump for heating the water to repeating when the water is heated to a high compressor outlet high temperature temperature then reduce the speed of running pump LP Too low Sensor failure EEV failure or Service intervention is needed evaporating evaporator fan failure pressure at the compressor inlet FR Protective thermal Long term increasing of Service intervention is needed compressor relay compressor input activated activated relay will remain disconnected until operator intervention IT Too low Sensor failure incorrect limits Service intervention is needed correct temp temperature of for heating or cooling of the limit for heating or cooling of the water The inlet water of heat water pump due to frost protection can not operate pump with water at a temperature below 7 C OT Outlet water Sensor failure incorrect limits Service intervention is needed correct temperature out of for heating or cooling of the temperature limit for heating of the water limits it is too low water The pump due to frost protection can not or too high operate with water at a temperature below 7 C and can not heats the water to a temp higher than 65 C FL Heat pump water Low or no water flow Check that the water circuit is bled the flow too low closures are opened and the pump speed is set to a reasonable value that can depend on the specific implementation
53. eekly moves to the top line of the display and the bottom line shows the first option for daily temperature corrections Weekly View Using the dial knob you can select the following options for weekly temperature corrections View This option allows to view and edit the weekly temperature corrections stored in the currently selected register Delete all This option allows to delete all the weekly temperature corrections stored in the currently selected register Activate This option allows to activate use the set weekly temperature corrections to control the heating operation Return Exits the temperature corrections setting Viewing and Editing the Weekly Heating Temperature Corrections For viewing activating and deleting the weekly temperature correction the same rules apply as for the daily correction that are described on pages 17 20 both menus have the same structure and their format depends on the heating mode When you open the View menu you can use the Edit option to create the first correction and then use the Append option to save it to the current register or you can use the Return option to exit editing without saving any changes If the current register contains any corrections menu View offers also the Delete option in addition to the Edit and Return options The Delete option allows you to delete the selected weekly correction After selecting the menu for weekly temperature corrections the display
54. el v 1 04 1 1 Heat Pump Control Board The heat pump control board is designed to control the heating of the water in one or two heating circuits heating of the domestic hot water heating of the pool water and to control the solar heating system This board is equipped with the necessary number of inputs for sensors used to measure temperature and pressure and to indicate the exceeding of the permitted values To control the compressor and auxiliary heater contactor heat exchanger fan circulation pumps and mixing and switching valves of the heating circuits the control board contains 18 relays that can switch voltage 230V with a maximum current of 2A In addition the board can control three stepper motors of electronically controlled expansion valves and it has four voltage outputs 0 10V to regulate the speed of evaporator fan and circulation pump Part of the control board is a switched mode power supply for powering the board and the other circuits of the heat pump The power supply contains control circuits to check the mains voltage and correct phase sequence and to distinguish between low or high price tariff for the supplied electricity The board can communicate with a superior system via RS485 serial interface On request it can be equipped with a LAN module for remote management and control via Ethernet and can also be extended by a GSM module for communication via a cellular network Dimensions of the control board are 267 x 125mm along
55. elect the Info option on the bottom line Setup Info After opening this menu Info moves to the top line of the display Use the dial knob to select the Pump statistics option on the bottom line Info Pump statistics After opening this menu Pump statistics moves to the top line of the display and the display shows Pump statistics Compr total time Using the dial knob and the confirmation button you can select and view the following statistics of the heat pump operation Compr total Displays the total time of compressor operation in hours time Defrost total Displays the total time of evaporator defrosting in hours time Bivalence Displays the total time of heat pump operation with auxiliary total time heater switched on in hours Emergency Displays the total time of operation in Emergency mode in total time hours Compr starts Displays the total number of compressor starts count AWV switches Displays the total number of 4 way valve switching count Total heat Displays the total heat produced by the heat pump in gigajoules produced GJ Total power Displays the total electricity consumed by the heat pump in kW consumed Heat from Displays the heat produced by the heat pump in gigajoules GJ dd mm yy since the last reset of registers Consum from Displays the electricity consumed by the heat pump in kW since dd mm yy the last reset of registers
56. en the heat pump operates at low ambient temperatures This causes the deterioration of the heat transfer between the surface of the evaporator and the ambient air The control electronics of the heat pump continuously evaluates this situation and if necessary starts the automatic defrosting of the evaporator During the defrosting the four way valve is switched to deliver the hot refrigerant from the compressor outlet to the evaporator and the frost is melting rapidly If necessary use the Defrost menu to manually defrost the evaporator even if the conditions for automatic defrosting are not met The Defrost menu contains no adjustments and is accessible only when the heat pump is not in an error state If an error is detected when entering the main menu only 10 Heat pump operation User level v 1 04 the Setup and Comfort options are accessible and the message HP error the number of errors and the error specification are displayed in the main menu See the Error list on page 61 for details When the status line is displayed press the confirmation button to enter the main menu If there is no error state use the dial knob to select Defrost option on the bottom line Menu Defrost After opening this menu Defrost moves to the top line of the display and according to the heat pump operation the display shows Defrost Start After confirming the Start option the control board performs a check and then st
57. enu use the dial knob to select the Solar start delta option Temperature settings Solar start delta After opening this menu display shows Solar start delta XX X Use the dial knob to set the required temperature difference in the range from 0 C to 25 0 C the typical value is about 10 0 C After confirmation the prompt appears Save Y N XX X Press the confirmation button to save the settings The confirmation message Saved OK briefly appears and then the display returns one level back Temperature settings Solar start delta Use the dial knob and the confirmation button to select and set the other temperatures or you can select and confirm the Return option repeatedly to exit the settings and return to the default state 33 Heat pump operation User level v 1 04 Setting the Temperature Difference for Disconnecting Solar Heating System from HP This menu allows to set the required difference between temperature of the media in the solar heating system and the temperature of the water in the tank to stop using the solar heating system for heating water in the heat pump tank When the status line is displayed press the confirmation button to enter the main menu and use the procedure described in chapter 7 1 2 on page 28 to open the Temperature settings menu After opening this menu use the dial knob to select the Solar stop delta option Temperature settings
58. equitherm control mode and the temperature corrections of the air temperature used in the heating control mode according to the reference room are stored separately in two sets of registers which are switched automatically when the heating mode is changed This means that all the operations described here will be carried out only in one set of registers corresponding to the currently used control mode When the status line is displayed press the confirmation button to enter the main menu and use the procedure described in chapter 7 1 1 on page 14 to open the Heating settings menu Use the dial knob to select the option for temperature correction prgramming Heating settings Temp corr program After opening this menu use the dial knob to select the option for temperature correction by date Temp corr program By Date After opening this menu By Date moves to the top line of the display and the bottom line shows the first option for temperature corrections by date By Date View Using the dial knob you can select following options for temperature corrections by date View This option allows to view and edit the temperature corrections by date Delete all This option allows to delete the temperature corrections by date It is available only when any temperature correction by date exists Activate This option allows to enable use the set temperature corrections by date to control the heating ope
59. estored 47 Heat pump operation User level v 1 04 7 3 Information about the Configuration and Operation of HP This menu allows to view the configuration and operation of the heat pump When the status line is displayed press the confirmation button to enter the main menu and use the dial knob to select the Setup option Menu Setup After opening this menu Setup moves to the top line of the display Use the dial knob to select the Info option on the bottom line Setup Info After opening this menu the display shows Info Mains voltage Using the dial knob and the confirmation button you can select and open the following options Mains voltage This menu allows to view the voltage of each phase the mains status and the current tariff Current This menu allows to view the duration of the high tariff for tariff times electricity HW SW This menu allows to view the circuit configuration version of configuration the control program and serial number of the heat pump HP Errors This menu allows to view the list of the heat pump operation list errors Pump This menu allows to view the basic statistical data about the heat statistics pump operation Return Exits the Info menu 7 3 1 Mains Voltage This menu allows to view the voltage of each phase the phase sequence and the current tariff When the status line is displayed press the confirmation button to enter the mai
60. et of registers Electricity consumed since the last reset of registers This menu allows to view the electricity in kW consumed by the heat pump since the last reset of registers Resetting the temporary registers of produced heat and consumed electricity This menu allows to resets the registers of heat produced and electricity consumed in the time interval after their the last reset When the status line is displayed press the confirmation button to enter the main menu and use the procedure described in chapter 7 3 5 on page 54 to open the Pump Statistics menu After opening this menu use the dial knob to select the Reset From register option Pump statistics Reset From register After confirmation the prompt appears Reset From register Save Y N After confirming the temporary registers of produced heat and consumed electricity are cleared and display returns one level back 55 Heat pump operation User level v 1 04 7 4 Settings the Connection to LAN WLAN and GSM Network This menu allows you to set parameters for connecting the heat pump to the LAN WLAN and GSM network When the status line is displayed press the confirmation button to enter the main menu Use the dial knob to select the Setup option on the bottom line Menu Setup After opening this menu Setup moves to the top line of the display Use the dial knob to select the Connection settings option on the bottom
61. ete new errors option errors are deleted and the confirmation message Saved OK briefly appears The display returns to the HP Errors list menu HP Errors list New errors Viewing the List of All Errors Use the procedure described in the beginning of this chapter on page 51 to open the menu for displaying all errors HP Errors list All errors If no error has occurred the display shows All errors No errors If an error was detected during the heat pump runtime the display shows All errors yy mm dd hh mm xx The bottom line contains from left to right the date and time when the error was detected and its sequential number representing its position in memory 0 to 95 Cursor is blinking on sequential number You can use the dial knob to select another sequential number After confirmation of the selected number the bottom line shows the numeric code and abbreviation of the error Example If the position 0 contains the error that was caused by the mains failure the display may show All errors XX XX XX XX PW 0 Where xx xx xx xx is the numeric error code a PW is the abbreviation for power supply The list of displayed errors is given in the appendix on page 67 in this manual By short press of the confirmation button you can switch between displaying the error specifications and displaying the time when the error was detected Blinking cursor remains on position of
62. ettings Setup Parameter settings After opening this menu Parameter settings moves to the top line of the display Use the dial knob to select the Tariff settings option on the bottom line Parameter settings Tariff settings After opening this menu Tariff settings moves to the top line of the display and the display shows Tariff settings DHW tariff stop 34 Heat pump operation User level v 1 04 Using the dial knob and the confirmation button you can select and open the following options to set the effect of the tariffs on the heat pump operation DHW tariff Disables the effect of high tariff for electricity on heating stop the domestic hot water DHW tariff Enables the effect of high tariff for electricity on heating start the domestic hot water HeW tariff Disables the effect of high tariff for electricity on heating the heating stop water HeW tariff Enables the effect of high tariff for electricity on heating the heating start water Pool tariff Disables the effect of high tariff for electricity on heating the pool stop Pool tariff Enables the effect of high tariff for electricity on heating the pool start Return Exits setting the effect of the tariff on the heat pump operation Disabling the Effect of the Tariff on Heating the DHW by HP This menu allows to set the outdoor temperature limit below which the heat pump heats the domestic hot water regardless of the
63. f backup battery failure after the power is turned off the error message is displayed after the heat pump is turned on and the cursor blinking on the Hour position indicates the sequence for setting the clock Clock error set 12 00 00 Use the dial knob to set the hours turn it to the right to increase the value or turn it to the left to decrease the value After setting the hours press shortly the confirmation button to set the minutes After setting the minutes in a similar way press shortly the confirmation button to set the seconds Check whether the set time is correct and press the confirmation button for a longer time to exit the time setting mode The display will show Heat pump operation User level v 1 04 Save Y N hh mm ss and the cursor is blinking on the Y YES position Press the confirmation button to save the time The confirmation message Time settings Saved OK will be briefly displayed and then the display will show Date settings 01 01 00 Set the date DD MM YY in a similar way as the time setting Press the confirmation button for a longer time to exit the date setting mode The display will show Save Y N dd mm yy Press the confirmation button to save the date The confirmation message Date settings Saved OK will be briefly displayed and then the display will return to the default state with the status line displayed
64. f each heating cycle Temp corr This menu allows you to adjust the temperature shifts depending program on the time of the day on the day of the week or on the date Equitherm Setting the equitherm curve for one or two heat pump heating curve circuits Runtime Setting the priorities for the heat pump operation priorities Heating mode This menu allows you to set the temperature control mode for the heat pump Return Exits the heat pump parameters setting Setting the DHW Reserve at the End of the Heating Cycle of the Heating Pump This parameter allows to set the minimum amount of the domestic hot water DHW in that should be in the tank at the end of each heating cycle The value 0 corresponds to the DHW start temperature at which the heating pump starts the heating and the value 100 corresponds to the DHW stop temperature at which the heating pump stops the heating At the end of the heating cycle if the temperature of the DHW in the tank is lower than the preset value the pump doesn t stop and it switches to DHW heating mode and heats the domestic hot water to the preset stop temperature i e to 100 When the status line is displayed press the confirmation button to enter the main menu and use the procedure described in chapter 7 1 1 on page 14 to open the Heating settings menu After opening this menu its first option is displayed Heating settings DHW min reserve After opening this menu the display
65. fter confirmation the prompt appears Save Y N Delete all The cursor is blinking on the Y YES position Press the confirmation button The message Saved OK briefly appears and then the display returns one level back 22 Heat pump operation User level v 1 04 Activation of Weekly Temperature Corrections This option allows to activate enable the set weekly temperature corrections to control the heating operation When the status line is displayed press the confirmation button to enter the main menu and use the procedure described in chapter 7 1 1 on page 14 to open the Heating settings menu Use the dial knob to select the option for temperature correction programming Heating settings Temp corr program After opening this menu use the dial knob to select the option for weekly temperature correction programming Temp corr program Weekly Open this menu and use the dial knob to select the option for activating the weekly temperature corrections that are saved it the current register according to the selected heating control mode Weekly Activate After confirmation the prompt appears Activate No The cursor is blinking on the NO position Use the dial knob to change the option to YES and confirm with the confirmation button The message Saved OK briefly appears and then the display returns one level back Weekly Activate If the equ
66. ge 27 Heating mode Equitherm control page 28 Eqt ctrl Ref room Reference temp Emergency mode Return Return Temperatur DHW start temp page 29 e settings DHW stop temp page 30 HeW start temp HeW stop temp page 31 Cooling start temp Cooling stop temp page 32 Pool start temp Pool stop temp page 33 Solar start delta Solar stop delta page 34 Return Tariff DHW tariff stop page 35 settings DHW tariff start page 36 HeW tariff stop HeW tariff start page 37 Pool tariff stop page 38 Pool tariff stop Return Bivalence Bivalence start temp page 39 settings Bivalence stop temp page 40 Bivalence delay Return Return Heat pump operation User level v 1 04 Setup Terminal Time page 42 user settings settings password Display Backlight set page 43 settings Contrast set page 44 Idle time Return Display Display mapping 0 F page 45 mapping Return Language page 47 selection Return Info Mains voltage page 48 Current tariff times page 49 HW SW configuration page 50 HP Errors list page 51 Pump Compr Starts count page 54 statistics 4wy switches count page 55 Compr total time Reverz total time Bivalence total time Emergency total time Total heat produced Total power consumed Heat from dd mm yy Consum from dd mm yy Reset From register Return Return Connectio LAN WAN As
67. he Temperature Parameters of the Heat Pump This menu allows to set the temperature constants for the heat pump control When the status line is displayed press the confirmation button to enter the main menu and use the dial knob to select the Setup option Menu Setup After opening this menu the display shows Setup Parameter settings 28 Heat pump operation User level v 1 04 After opening this menu use the dial knob to select the Temperature settings option After opening this menu Temperature settings moves to the top line of the display and the display shows Parameter settings Temperature settings Temperature settings DHW start temp Using the dial knob and the confirmation button you can select and open the following options DHW start Setting the lower limit of the domestic hot water temperature in the temp DHW tank at which the heat pump starts to heat DHW DHW stop Setting the upper limit of the domestic hot water temperature in the temp DHW tank at which the heat pump stops to heat DHW HeW start Setting the lower limit of the heating water temperature in the HeW temp HeW tank at which the heat pump starts to heat HeW HeW stop Setting the upper limit of the heating water temperature in the temp HeW tank at which the heat pump stops to heat HeW Cooling start temp Cooling stop Setting the heating water temperature at which the h
68. he confirmation button and then by using the Append option Edit Append After re opening the menu for viewing the weekly corrections you can Edit another weekly corrections and Append them to the current register in the similar way up to total number of 56 When you open the View menu if there are several weekly corrections stored in the actual registry you can use the dial knob to select the desired correction confirm it by the confirmation button and Edit or Delete it Like in the case of daily corrections the edited correction is saved under a new number using the Add option when using the Save option the edited correction is saved under the same number and overwrites the original correction Deleting All Weekly Corrections from the Current Registry This option allows to delete all the weekly temperature corrections stored in the currently selected register When the status line is displayed press the confirmation button to enter the main menu and use the procedure described in chapter 7 1 1 on page 14 to open the Heating settings menu Use the dial knob to select the option for temperature correction programming Heating settings Temp corr program After opening this menu use the dial knob to select the option for weekly temperature correction programming Temp corr program Weekly Use the dial knob to select the option for deleting all the weekly corrections Weekly Delete all A
69. high tariff for electricity If the ambient temperature is higher than the set limit the DHW is heated only at the low tariff If the ambient temperature drops below the set limit the DHW is heated as necessary regardless of the current tariff When the ambient temperature increases effect of the tariff is enabled only when the outside temperature exceeds the limit that enables the effect of the tariff see the next chapter The temperature limit that enables the effect of the tariff must be set about 2 C higher than the temperature limit that disables the effect of the tariff hysteresis To permanently disable the effect of the tariff you must set both the enabling and disabling temperature limits for heating DHW according to the tariff to the maximum possible value i e to 30 C Ambient temp 4 Tarif start i hysteresis Tarif stop Time Fig 5 Diagram of the disabling enabling the effect of the tariff When the status line is displayed press the confirmation button to enter the main menu and use the procedure described in chapter 7 1 3 on page 34 to open the Tariff settings menu After opening this menu its first option is displayed Tariff settings DHW tariff stop After opening this menu display shows DHW tariff stop XX X 85 Heat pump operation User level v 1 04 Use the dial knob to set the required temperature in the range from 30 0 C to 30 0 C After confirm
70. iff The temperature limit that enables the effect of the tariff must be set about 2C higher than the temperature limit that disables the effect of the tariff hysteresis When the status line is displayed press the confirmation button to enter the main menu and use the procedure described in chapter 7 1 3 on page 34 to open the Tariff settings menu After opening this menu use the dial knob to select the HeW tariff start option NTariff settings HeW tariff start After opening this menu display shows HeW tariff start XX X Use the dial knob to set the required temperature in the range from 30 0 C to 30 0 C After confirmation the prompt appears Save Y N XX X Press the confirmation button to save the settings The confirmation message Saved OK briefly appears and then the display returns one level back Tariff settings HeW tariff start Use the dial knob and the confirmation button to select and set the other tariffs or you can select and confirm the Return option repeatedly to exit the settings and return to the default state 37 Heat pump operation User level v 1 04 Disabling the Effect of the Tariff on Heating the Pool by HP This menu allows to set the outdoor temperature limit below which the heat pump heats the pool water regardless of the high tariff for electricity If the outdoor temperature is higher than the set limit the pool water is heated only at
71. irectly open the Setup menu if the password is enabled you must enter the password first and confirm it If you forget the password you can disable its use by turning off the heat pump and then turning it on again while holding the confirmation button You need to hold the confirmation button all the time while initialization of the heat pump is being performed i e until the display enters the default state The result is the same as when the user passwords is disabled in the User password menu in the heat pump setup Menu Setup When the password is enabled after pressing the confirmation button Setting moves to the top line of the display and the bottom line displays the prompt to enter the password Setup Password ae RR Use the dial knob to set the first character of your password and shortly press the confirmation button to set the next character Set the next character in a similar way and repeat this to set the whole password Press the confirmation button for a longer time to save the password If an incorrect password is entered the display shows Setup Incorrect input and then the display returns one level back in the menu If the correct password is entered the Setup menu and its first option appear Setup Parameter settings Use the dial knob to select the desired setting on the bottom line of the display and press the confirmation button to enter its menu Parameter
72. itherm heating control is selected the activated weekly temperature correction are added according to their start times to the required temperatures of the heating water If the heating control according to the temperature in the reference room is selected the activated weekly temperature corrections are added to the required air temperatures in the reference room Deactivation of Weekly Temperature Corrections To deactivate the weekly temperature corrections it is necessary to select the option for activation of the temperature corrections as described in the previous section and then confirm the default option Activate No After confirming the NO option the weekly temperature correction are deactivated and heating will be controlled according to the selected contro mode without using the daily temperature correction 23 Heat pump operation User level v 1 04 Heating Temperature Correction by Date This menu allows you to set the date and time from which the preset daily or weekly corrections will be used This allows for example to set lower heating before leaving for vacation and use the correction by date to set the time to restore the selected heating program before returning from vacation While setting up the correction by date you must also enter the register number and the type of program to contro heating from the specified date The temperature corrections of the heating water temperature used in the
73. l back Deleting All Daily Corrections from the Current Registry This option allows to delete all the daily temperature corrections stored in the current selected register When the status line is displayed press the confirmation button to enter the main menu and use the procedure described in chapter 7 1 1 on page 14 to open the Heating settings menu Use the dial knob to select the option for temperature correction programming Heating settings Temp corr program After opening this menu use the dial knob to select the option for daily temperature correction programming Temp corr program Daily Use the dial knob to select the option for deleting all the daily corrections Daily Delete all After confirmation the prompt appears Save Y N Delete all The cursor is blinking on the Y YES position Press the confirmation button The message Saved OK briefly appears and then the display returns one level back 19 Heat pump operation User level v 1 04 Activation of Daily Temperature Corrections This option allows to activate enable the set daily temperature corrections to control the heating operation When the status line is displayed press the confirmation button to enter the main menu and use the procedure described in chapter 7 1 1 on page 14 to open the Heating settings menu Use the dial knob to select the option for temperature correction programming Hea
74. level v 1 04 Use the dial knob and the confirmation button to select and set the other tariffs or you can select and confirm the Return option repeatedly to exit the settings and return to the default state 7 1 4 Bivalence Settings One part of the heat pump is an auxiliary electric heater with input power of 3kW which may be used to heat the water in case that the heat pump power is not sufficient to ensure the required temperature of the domestic hot water or heating water This auxiliary electric heater will be used also in case of compressor or evaporator failure to provide heating in the Emergency mode When the status line is displayed press the confirmation button to enter the main menu and use the dial knob to select the Setup option on the bottom line Menu Setup After opening this menu Setup moves to the top line of the display and the bottom line shows the Parameter settings Setup Parameter settings After opening this menu Parameter settings moves to the top line of the display Use the dial knob to select the Bivalence settings option on the bottom line Parameter settings Bivalence settings After opening this menu Bivalence settings moves to the top line of the display and the display shows Bivalence settings Bivalence start temp Using the dial knob and the confirmation button you can select and open the following options of the bivalence settins Bivalence
75. ly interval By Date Setting the date and time from which the time corrections prepared in the selected registry will be applied Return Exits the temperature corrections setting Selecting the Current Temperature Correction Register This option is designed to select the current temperature corrections register corrections made will be stored in this register Each register can contain up to 8 daily and 56 weekly corrections When the status line is displayed press the confirmation button to enter the main menu and use the procedure described in chapter 7 1 1 on page 14 to open the Heating settings menu Use the dial knob to select the option for temperature correction programming Heating settings Temp corr program After opening this menu the display shows Temp corr program Current register After opening this menu Current register moves to the top line of the display and the display shows the number of the current temperature correction register Current register x On the position of the character x you can select register number 0 3 Confirm the set value and a prompt appears Save Y N x Press the confirmation button to save the settings The confirmation message Saved OK briefly appears and then the display returns one level back Temp corr program Current register Using the dial knob you can proceed with setting up another temperature corrections
76. n memory 0 to 95 Cursor is blinking on sequential number You can use the dial knob to select another sequential number After confirmation of the selected number the bottom line shows the numeric code and abbreviation of the error Example If the position 0 contains the error that was caused by the mains failure the display may show New errors XX XX XX XX PW 0 Where xx xx xx xx is the numeric error code a PW is the abbreviation for power supply The list of displayed errors is given in the appendix on page 61 in this manual By short press of the confirmation button you can switch between displaying the error specifications and displaying the time when the error was detected Blinking cursor remains on position of the sequential number After reviewing the specification and time of the error you can select and view another recorded error if any exists It is possible to display up to 96 last errors If more errors have occurred the oldest ones are overwritten by the new ones Press the confirmation button for a longer time to exit the error viewing mode the display shows the prompt to delete the list of new errors New errors Delete new errors 52 Heat pump operation User level v 1 04 You can confirm the proposed option to delete the list of new errors or you can use the dial knob to select Return option and confirm it to leave the menu without deleting the list of new errors If you confirm the Del
77. n menu and use the dial knob to select the Setup option Menu Setup After opening this menu Setup moves to the top line of the display Use the dial knob to select the Info option on the bottom line Setup Info After opening this menu Info moves to the top line of the display and the display shows Info Mains voltage After opening this menu the display shows Mains voltage 01 235 5 236 8 234 4 where 01 is the two digit information about the mains status followed by the voltage of each phase in volts The sequence of voltages corresponds to the sequence of the power terminals on the board From left to right are shown the voltages of the phases R S and T connected to the terminals 4 3 and 2 of the heat pump control board 48 Heat pump operation User level v 1 04 Mains Status The mains status consists of two hexadecimal characters If all the phases have the nominal voltage and are connected in the correct sequence the first character is 0 and the second character is 0 at the low tariff or 1 at the high tariff If the first character other than 0 there is some voltage out of tolerance or incorrect phase sequence To decode the status it is needed to convert the hexadecimal number into the binary format where 0 OK or the low tariff and 1 incorrect voltage phase sequence or a high tariff Status on the display 0 1 hexadecimal
78. n menu and use the procedure described in chapter 7 1 2 on page 28 to open the Temperature settings menu After opening this menu its first option is displayed Temperature settings DHW start temp After opening this menu the display shows DHW start temp XX Use the dial knob to set the required temperature in range from 0 to 65 C After confirmation the prompt appears Save Y N XX 29 Heat pump operation User level v 1 04 Press the confirmation button to save the settings The confirmation message Saved OK briefly appears and then the display returns one level back Temperature settings DHW start temp Use the dial knob and the confirmation button to select and set the other temperatures or you can select and confirm the Return option repeatedly to exit the settings and return to the default state Setting the Stop Temperature for Heating the DHW This menu allows to set the maximum temperature of the domestic hot water in the DHW tank When the temperature reaches the set value heating is stopped and if there is no other reason to run the heat pump it is turned off When the status line is displayed press the confirmation button to enter the main menu and use the procedure described in chapter 7 1 2 on page 28 to open the Temperature settings menu After opening this menu use the dial knob to select the DHW stop temp option Temperature settings DHW s
79. nd the control modes for the heat pump settings heating Temperature Setting the temperature parameters of the heat pump settings Tariff Setting the operation of the heat pump according to tariff of the settings electricity Bivalence Setting the conditions for the use of auxiliary heating during the settings heat pump operation Return Exits the heat pump parameters setting 7 1 1 Heating Settings This menu allows to set the parameters for the heating operation of the heat pump When the status line is displayed press the confirmation button to enter the main menu and use the dial knob to select the Setup option Menu Setup After opening this menu Setup moves to the top line of the display and the bottom line shows the Parameter settings Setup Parameter settings After opening this menu Parameter settings moves to the top line of the display and the display shows Heating settings in the bottom line Parameter settings Heating settings After opening this menu Heating settings moves to the top line of the display and the display shows Heating settings DHW min reserve Using the dial knob and the confirmation button you can select and open following options for setting the heating operation 14 Heat pump operation User level v 1 04 DHW min Setting the minimum amount of the domestic hot water DHW in reserve that should be in the tank at the end o
80. ng to the pre programmed algorithms and the display returns to the default state During the stopping of the pump only the Setup and Comfort menus are accessible no heat pump function can be set until the complete stop of the unit Heat pump operation User level v 1 04 4 Cooling Cooling menu is designed to start or stop the cooling mode of the heat pump According to your settings the heat pump can heat the domestic hot water and the water in the pool and cools the water in the HeW tank The cooled heating water can be used in the summer to cool down the living spaces The Cooling menu contains no adjustments and is accessible only when the heat pump is not in an error state If an error is detected when entering the main menu only the Setup and Comfort options are accessible and the message HP error the number of errors and the error specification are displayed in the main menu See the Error list on page 61 for details When the status line is displayed press the confirmation button to enter the main menu If there is no error state use the dial knob to select the Cool option on the bottom line Menu Cooling After opening this menu Cooling moves to the top line of the display and if the pump is switched off the display shows Cooling Start After confirming the Start option the control board performs a check of the parameters and then starts the heat pump in the cooling mode C F P Cool 10 52
81. nguage version Error when transferring the selected language version from the non volatile memory to the working memory Error will be corrected automatically reloading the selected language version from the non volatile memory to the working memory or reselecting language version using the rotary selector or re switching on of the mains input of the heat pump 62 Heat pump operation User level v 1 04 Errors of the temperature sensors Code Description Possible cause Repairing TO OT failure Broken or shorted wires to the Service intervention is needed water temperature sensor at the heat pump outlet T1 ET failure Broken or shorted wires to the Service intervention is needed temperature sensor at the compressor outlet T2 SUT failure Broken or shorted wires to the Service intervention is needed temperature sensor of the compressor suction T3 ET and SUT Broken or shorted wires to Service intervention is needed failure these temperature sensors T4 AT failure Broken or shorted wires to the Service intervention is needed ambient outdoor temperature sensor T5 ET and AT Broken or shorted wires to Service intervention is needed failure these temperature sensors T6 SUT and AT Broken or shorted wires to Service intervention is needed failure these temperature sensors T7 ET SUT and AT Broken or shorted wires to Service intervention is needed failure these temperature sensors
82. of plumbing ET Too high Sensor failure EEV failure at Check the ET sensor If the error occurs temperature at the EVI heat exchanger or EEV repeatedly when heating of the water to compressor outlet incorrect setting higher temperatures check the EEV at EVI heat exchanger and setting of its control parameters PW Failure of three Voltage out of tolerance Service intervention is needed phase power interrupted connection of phase incorrect phase order FE Incorrect It is checked when powering When this error is detected first stored checksum for the heat pump error occurs when language version is automatically loaded current language a data breach in the working from the non volatile memory to the working selection memory memory and this is always English FF Incorrect list of It is checked when changing Service intervention is needed uploading of languagesin a the language version the error a new set of languages from an external non volatile occurs when the data error in computer via RS485 serial interface will be memory non volatile memory necessary FC Wrong language It is checked when changing Service intervention is needed uploading of selected the language version the error a new set of languages from an external PC occurs when the data error in non volatile memory via serial interface will be necessary 61 Heat pump operation User level v 1 04 FD Unsuccessful change of la
83. oom mode 6 1 Quick Temperature Adjustment in the Equitherm Control Mode In the equitherm control mode the heated water temperature depends on the outdoor temperature In addition the heated water temperature is adjusted by daily and weekly temperature corrections The set parameters especially during the first heating season may not be suitable and should be adapted to the building characteristics and user requirements The Comfort menu allows you to shift heated water temperature compared to equitherm curves with possible time corrections in one or two heating circuits After confirming the set shift the corrected equitherm curve is adjusted accordingly This shift of the corrected equitherm curve is valid until it is reseted in the Comfort menu or until reaching such date and time when the shift of the corrected equitherm curves set in the Comfort menu is cancelled The dependence between the change of the water temperature and the air temperature in the building will depend on the characteristics of the building and the outdoor temperature At low outdoor temperatures it will be necessary to set a greater shift of the heating water temperature in order to achieve the same shift of the internal temperature After verifying the set correction of the heating water temperature it is possible to adjust the equitherm curves When the status line is displayed press the confirmation button to enter the main menu and use the dial knob to select the Comfor
84. ority of the third circuit Off circuit is not heated z The lowest priority for heating the circuit The middle priority for heating the circuit T The highest priority for heating the circuit w N Be O After setting the required priorities press the confirmation button for a longer time to save the set priorities Save Y N TE1 x DHW x Pool x Press the confirmation button to save the settings The confirmation message Saved OK briefly appears and then the display returns one level back Heating settings Runtime priorities Use the dial knob and the confirmation button to select and set the other parameters of heating or you can select and confirm the Return option repeatedly to exit the settings and return to the default state 27 Heat pump operation User level v 1 04 Setting the Heat Pump Heating Mode This menu allows you to set the temperature contro mode for the heat pump When the status line is displayed press the confirmation button to enter the main menu and use the procedure described in chapter 7 1 1 on page 14 to open the Heating settings menu Use the dial knob to select the desired option Heating settings Heating mode After opening this menu the display shows Heating mode Equitherm control In this menu you can use the dial knob and the confirmation button to select and save the desired heat pump control mode Equitherm control
85. ormance The most important settings are located on the highest manufacturing level This level is only accessible to the heat pump manufacturer The important settings that adjust the heat pump performance according to the particular user conditions and their improper setup would cause a malfunction are located on the service level and protected by the service password The service password can not be changed and its use is mandatory It is available to authorized service and installation Other settings are accessible to the user of the heat pump and can also be protected against tampering by optional user password Menu User Password allows to enable disable the password and change it When the status line is displayed press the confirmation button to enter the main menu Use the dial knob to select the Setup option on the bottom line Menu Setup After opening this menu Setup moves to the top line of the display Use the dial knob to select the User Password option on the bottom line Setup User password After opening this menu User password moves to the top line of the display and depending on the use of password the display shows Password On or Password Off User password Password On After confirmation User password Password FR RR kk Cursor is blinking on the position of the first character Use the dial knob to set the first character of your password and shortly pre
86. p operation User level v 1 04 Setting the Equitherm Curve for Heat Pump Heating Control To achieve the maximum thermal comfort in heated rooms the heat pump adjusts the heating water temperature depending on the outdoor temperature To express the dependence of the heating water temperature on the outdoor temperature equitherm heating curve is used You can set the heating curve for one or two heating circuits Each curve is made up of four points that can be adjusted over a wide range to achieve the required thermal comfort Each point is specified by the outdoor air temperature Tai and the associated heating water temperature Twa This means that the outdoor temperature is always assigned to the heating water temperature For each value of the outdoor temperatures corresponding temperature of heating water is calculated using the four specified points of the equitherm curve and the linear approximation Shape of the curve is shown in Figure 4 Heating water temperature A Twa A lt gt Tai A Tai B Tai C Tai D OC j Ambient temperature Fig 4 Equitherm curve When the status line is displayed press the confirmation button to enter the main menu and use the procedure described in chapter 7 1 1 on page 14 to open the Heating settings menu Use the dial knob to select the option for setting the equitherm curve Heating settings Equitherm curve After confirmation the display offers setting of
87. ration Return Exits the temperature corrections setting Viewing and Editing of Temperature Correction by Date This menu allows you to view and edit the date time number of the register that contains the temperature corrections and the type of the correction daily or weekly to be used from the specified date and time You must select the register to be used and save the required daily or weekly corrections to this register in advance After selecting the option for temperature corrections by date the display shows By Date View After opening this menu if there is not any set correction the display will show yy mm dd hh mm date Da Rx After pressing the confirmation button you can use dial knob and confirmation button to select and set the year month day hour and minute when the temperature correction by date should begin Subsequently specify the type of the correction daily or weekly and number of the register at the position of the character x that contains the preset corrections 24 Heat pump operation User level v 1 04 For example enter yy mm dd hh mm date 13 02 10 08 00 Da R1 Press the confirmation button for a longer time The display shows By Date Save After confirmation the prompt appears Save Y N Save After confirmation the message Saved OK briefly appears and then the display returns one level back If you open the stor
88. ready set the real time clock and the heat pump is not in an error state the initial message is followed by displaying the status of the main parts of the heat pump and the current time on the top line of the display and the selected temperatures on the bottom line of the display This is the default state i e the display in the standby mode before any intervention of the operator CFP OFF 10 52 AT 2 4 CT 6 8 The display can show two lines each of 20 characters The first row that shows the heat pump status and the current time in hours and minutes is so called display status line In the case above the compressor character C the fan character F and the pump character P are off the symbol OFF The bottom line shows the selected temperatures in C In the case above it is the ambient temperature AT and the heat pump evaporator temperature CT The line shows two temperatures it is possible to display up to 16 temperatures Using the dial knob you can shift the displayed lines in both directions and sequentially check all the measured temperatures Displaying up to 16 temperatures and their placement in the individual lines of the display is given by heat pump display settings which can by configured by user Besides that the last five lines show the heat pump operating parameters their are displayed in a fixed format and designed to check the heat pump performance If the real time clock has not been set yet or in case o
89. rrection After confirming the Edit option cursor is blinking on the position of the correction starting hour You can set and save the new correction in the same way as the previous correction 18 Heat pump operation User level v 1 04 For example you can modify the original first correction Edit EQ EQ2 01 09 00 5 0 7 0 and press the confirmation button for a longer time to add the correction number 02 to the current register Edit Append You can continue in this way until creating the maximal number of the corrections If the daily corrections are made you can open the View menu and use the dial knob to select and view the individual correction You can Edit or Delete the selected correction or you can use the Return option to exit the selected item without making any changes To edit the selected correction press shortly the confirmation button to enter the edit mode and modify the correction Press the confirmation button for a longer time Now you must use the dial knob to switch from the Append to Save option and press the confirmation button to rewrite the selected correction Edit Save If you would confirm the Append option the adjusted correction would by added as a new correction to the current register and the the edited correction that you wanted to change would remain unchanged After confirmation the message Saved OK briefly appears and then the display returns one leve
90. s To select the current correction register the Current register option is provided all corrections made will be stored in the selected register The temperature corrections of the heating water temperature used in the equitherm control mode and the temperature corrections of the air temperature used in the heating control mode according to the reference room are stored separately in two sets of registers which are 15 Heat pump operation User level v 1 04 switched automatically when the heating mode is changed When the status line is displayed press the confirmation button to enter the main menu and use the procedure described in chapter 7 1 1 on page 14 to open the Heating settings menu Use the dial knob to select the option for temperature correction programming Heating settings Temp corr program After opening this menu the display shows Temp corr program Current register Use the dial knob to select the desired mode of the temperature corrections of the heat pump Current Selection of one of four temperature correction registers each register can hold up to 8 daily and 56 weekly temperature corrections Daily Setting the corrections of the heating water temperature applied to the temperature determined by the control algorithms with 24 hour interval Weekly Setting the corrections of the heating water temperature applied to the temperature determined by the control algorithms with week
91. s Comfort Setup HP Error and Return If the heat pump is not in an error state following menu items are accessible Heating This menu allows to turn on off the heat pump in the Heating mode or the Emergency heating mode Cooling This menu allows to turn on off the heat pump in the Cooling mode Defrost This menu allows to manually start the heat pump evaporator defrosting Comfort This menu allows quick adjustment of the temperature in the heated space in comparison to the temperature set by the selected heating mode Setup This menu allows to set all the necessary parameters for the heat pump operation Return Exits the parameters settings or heat pump management and returns to the previous level of the menu The value being set is increased by turning the dial knob to the right and decreased by turning the dial knob to the left If the line contains only one numerical parameter after setting the desired value and pressing the confirmation button the prompt Save Y N appears and after confirmation the message Saved OK briefly appears If the line contains several parameters such as hours minutes and seconds cursor is blinking on the position of the parameter being set To set up the next parameter press shortly the confirmation button Each short press will move the cursor one parameter to the right if the last parameter was selected cursor will move again to the first parameter This allows to correct wrong values
92. s O to 3 While waiting for the start of the temperature correction by date symbols for appropriate heating time correction DO to D3 or TO to T3 and symbol DA indicating the 8 Heat pump operation User level v 1 04 correction by date are alternately displayed in a time interval of about one second The bottom line of the display shows the selected pair of temperatures you can shift the displayed parameters in both directions using the dial knob The position of the temperatures on the display lines can be set in the Display mapping menu The Heating menu can be left without starting up the heat pump In this case select the Return option on the display bottom line and press the confirmation key Heating Return If the Heating menu is opened when the heat pump is running the display shows the option to stop the pump Heating Stop After confirming the Stop option the heat pump stops according to the pre programmed algorithms and the display returns to the default state During the stopping of the pump only the Setup and Comfort menus are accessible no heat pump function can be set until the complete stop of the unit 3 2 Emergency Heating If the Emergency mode setting have been changed from NO to YES according to chapter 7 1 1 on page 28 Heating menu allows to start heat pump in the Emergency mode In the default state press the confirmation button to enter the main menu The bottom line displays
93. shows Contrast set EERE The number of characters m 1 to 16 indicates the set contrast of the display Use the dial knob to set the contrast and press shortly the confirmation button to save it Display returns one level back Terminal settings Contrast set Use the dial knob to select and set the other parameters of the display settings or you can select and confirm the Return option repeatedly to exit the heat pump settings and return to the default state Setting the Idle Time to Restore the Default Display This menu allows to set the time interval to restore the default display if no operator action is taken If the operator performs no action during the set time interval display returns to the default state When the status line is displayed press the confirmation button to enter the main menu and use the procedure described in chapter 7 2 2 on page 43 to open the Display settings menu After opening this menu use the dial knob to select the Idle time option on the bottom line Terminal settings Idle time After opening this menu the display shows Idle time XXX Use the dial knob to set the required time in the range from 0 to 250 seconds Save Y N XXX Press the confirmation button to save the settings The confirmation message Saved OK briefly appears and then the display returns one level back Terminal settings Idle time Use the dial
94. shows DHW min reserve XX where xx indicates the value in to maintain the required DHW temperature Use the dial knob to set the value in the range from 0 to 99 Press the confirmation button to confirm the set value and a prompt appears Save Y N XX Press the confirmation button to save the settings The confirmation message Saved OK briefly appears and then the display returns one level back Heating settings DHW min reserve Use the dial knob to select and set the other parameters of the heating or you can select and confirm the Return option repeatedly to exit the heat pump settings and return to the default state Temperature Correction of the Heating Operation This menu allows you to adjust the temperature shifts in the building depending on the time of the day on the day of the week or on the date According to the stored corrections and the selected control mode the control electronics adjusts the temperature of the water in the heating circuits if the equitherm control mode is used or it adjusts the air temperature in the reference room if the reference room mode is used This allows to reduce the temperature for example during the night time in case of absence of people in the building leaving for work vacation etc To save the daily and weekly correction up to 4 temperature correction registers can be used Each register can contain up to 8 daily and 56 weekly correction
95. signed IP address page 57 as settings Preset IP address settings Network mask Gateway DNS FTPS PING address MAC address Return GSM Phone numbers page 58 settings GSM switch off delay page 59 Return Return User On Off page 60 password Return Return Return Heat pump operation User level v 1 04 3 Heating Heating menu is designed to start or stop the heating mode of the heat pump This menu contains no adjustments and is accessible only when the heat pump is not in an error state If an error is detected when entering the main menu only the Setup and Comfort options are accessible and the message HP error the number of errors and the error specification are displayed in the main menu See the Error list on page 61 for details In case of a compressor failure an evaporator failure a refrigerant leakage or other failure of the heat pump it is possible to provide an emergency heating and domestic hot water heating using an auxiliary electric heater bivalent source To run in the emergency mode the auxiliary electric heater the circulation pump and the heat exchanger must be operational To switch the heat pump into the emergency mode it is necessary to change the Emergency mode settings from NO to YES in the Heating settings menu see chapter 7 1 1 on page 28 With Emergency mode set to YES Heating option is accessible in the main menu even when error is detected and you can run the heat pump in the Emergency mode
96. splay shows View EQ1 EQ2 00 In the heating mode according to the temperature in the reference room only one value of the temperature shift dT is diplayed instead of two temperatures EQ1 and EQ2 If there is no correction made 00 appears in place of the correction serial number and the data about the beginning and the value of the correction for the first and second heating circuit are also empty Press shortly the confirmation button to edit the first time correction the display changes from View to Edit If the daily correction register is empty you can use the dial knob to select Return instead of Edit confirm it and exit the editing of the first correction Edit EQ EQ2 00 Press the confirmation button to confirm the Edit option cursor is blinking on the position of the first correction starting hour Use the dial knob to to set the desired hour press shortly the confirmation button use the dial button to set the minutes and press shortly the confirmation button In the equitherm heating mode you can set the heated water temperature correction in the first heating circuit Use the dial knob to set the correction in the range of 9 9 C to 9 9 C Press shortly the confirmation button to set the heated water temperature correction in the second heating circuit In the heating mode according to the temperature in the reference room you can set correction dT in the range of 4 9
97. ss the confirmation button to set the next character Set the next character in a similar way and repeat this to set all six characters of the password After setting the last character press the confirmation button for a longer time to save the password The prompt appears User password Save Y N Press the confirmation button to save the settings The confirmation message Saved OK briefly appears and then the display returns one level back Setup User password Use the dial knob to set the other settings or select and confirm the Return option to exit this menu If the user password is enabled it is required each time you access the Setup menu of the heat pump If you forget the password you can disable its use by turning off the heat pump and then turning it on again while holding the confirmation button You need to hold the confirmation button all the time while initialization of the heat pump is being performed i e until the display enters the default state 60 Heat pump operation User level v 1 04 8 Summary of heat pump errors When the status bar is displayed pressing of the button shows the main menu If heat pump error is detected when entering the main menu an error message will display codes up to five errors Meaning of detected errors is shown in the following table Code Description Possibly causes Repair method HP High condensing Excessive spe
98. t option si Heat pump operation User level v 1 04 Menu Comfort After opening this menu Comfort moves to the top line of the display and the bottom line shows the heating water temperature shifts compared to the equitherm temperatures of the heating circuits Comfort EQ1 x x EQ2 x x Use the dial knob to set the temperature shift in the range from 9 9 to 9 9 C in both circuits the setting of the second circle can be accessed by short press of the confirmation button Confirm the settings by long press of the confirmation button The display shows Save Y N EQ1 x x EQ2 x x and the cursor is blinking on the Y YES position Press the confirmation button to save the settings The confirmation message Comfort Saved OK is displayed for 2 seconds and then the display returns one level back in the menu 6 2 Quick Temperature Adjustment in the Reference Room Mode When the heating temperature is controlled according to the reference room temperature the temperature corrections directly regulate the air temperature in the reference room This means that in the heating mode according to the temperature in the reference room you can t use the same time temperature correction as in the heating mode with equithermal control where corrections of the temperature adjust the heating water temperature It is necessary to prepare two sets of the temperature correction in the in
99. t pump errors 9 Contents 65 Manufacturer Sinclair Corporation Ltd 1 4 Argyll Street London W1F 7LD UK Supplier and technical support Nepa spol s r o Purkynova 45 612 00 Brno Czech Republic WWW nepa cz Toll free info line 420 800 100 285
100. t the heat pump inlet Outlet temperature water temperature at the heat pump outlet Domestic hot water temperature Heating water temperature Reference room temperature Output water temperature in the circuit TE1 radiators Output water temperature in the circuit TE2 underfloor heating Pool temperature Solar heating system temperature Compresor outlet temperature EVI exchanger outlet temperature Besides these temperatures the last five lines display 10 operation parameters their order is fixed and can t be changed PQ1 PQ2 P07 T07 P18 T18 EkW TkW Q m COP Required output water temperature in the circuit TE1 radiators Required output water temperature in the circuit TE2 underfloor heating Compressor suction pressure Evaporation temperature at the compressor inlet EVI compressor suction pressure at the inlet Evaporation temperature at the EVI compressor inlet Input power of the heat pump Heat power of the heat pump in kW Water flow through the heat pump in litres sec Coefficient of performance of the heat pump 46 Heat pump operation User level v 1 04 7 2 4 Setting the Language Version of the Heat Pump Control Program This menu is designed to select the language version of the heat pump control program and is accessible only when the heat pump is in the stop state When the status line is displayed press the confirmation button to enter the main menu and use the dial knob to select the Se
101. ter opening this menu display shows DHW tariff start XX X Use the dial knob to set the required temperature in the range from 30 0 C to 30 0 C After confirmation the prompt appears Save Y N XX X Press the confirmation button to save the settings The confirmation message Saved OK briefly appears and then the display returns one level back Tariff settings DHW tariff start Use the dial knob and the confirmation button to select and set the other tariffs or you can select and confirm the Return option repeatedly to exit the settings and return to the default state Disabling the Effect of the Tariff on Heating the HeW by HP This menu allows to set the outdoor temperature limit below which the heat pump heats the heating water regardless of the high tariff for electricity If the outdoor temperature is higher than the set limit the HeW is heated only at the low tariff If the outdoor temperature drops below the set limit the HeW is heated regardless of the current tariff When the outdoor temperature increases effect of the tariff is enabled only when the outside temperature exceeds the limit that enables the effect of the tariff see the next chapter The temperature limit that enables the effect of the tariff must be set about 2 C higher than the temperature limit that disables the effect of the tariff hysteresis When the status line is displayed press the confirmation button to enter th
102. the sequential number After reviewing the specification and time of the error you can select and view another recorded error if any exists It is possible to display up to 96 errors If more errors have occurred the oldest ones are overwritten by the new ones Press the confirmation button for a longer time to exit the error viewing mode The display returns to the HP Errors list menu HP Errors list All errors In contrast to viewing the list of new errors you cant delete the list of all errors new Recorded errors remain saved until all 64 memory positions are filled If more errors have occurred the oldest ones are overwritten by the new ones Use the Return option to exit the HP Errors list menu The display returns one level back You can select and confirm the Return option repeatedly to exit the settings and return to the default state To return to the default state from any level of the menu you can also press and hold the confirmation button until the display returns to the default state 53 Heat pump operation User level v 1 04 7 3 5 Statistics of the Heat Pump Operation This menu allows to view the basic statistical data about the heat pump operation When the status line is displayed press the confirmation button to enter the main menu and use the dial knob to select the Setup option Menu Setup After opening this menu Setup moves to the top line of the display Use the dial knob to s
103. ting settings Temp corr program After opening this menu use the dial knob to select the option for daily temperature correction programming Temp corr program Daily Open this menu and use the dial knob to select the option for activating the daily temperature corrections that are saved it the current register according to the selected heating control mode Daily Activate After confirmation the prompt appears Activate No The cursor is blinking on the NO position Use the dial knob to change the option to YES and confirm with the confirmation button The message Saved OK briefly appears and then the display returns one level back Daily Activate If the equitherm heating control is selected the activated daily temperature correction are added according to their start times to the required temperatures of the heating water If the heating control according to the temperature in the reference room is selected the activated daily temperature correction are added to the required air temperatures in the reference room Deactivation of Daily Temperature Corrections To deactivate the daily temperature corrections it is necessary to select the option for activation of the temperature corrections as described in the previous section and then confirm the default option Activate No After confirming the NO option the daily temperature corrections are deactiv
104. tion button to enter the main menu and use the dial knob to select the Setup option Menu Setup After opening this menu Setup moves to the top line of the display Use the dial knob to select the Terminal settings option on the bottom line Setup Terminal settings After opening this menu Terminal settings moves to the top line of the display and the display shows Terminal settings Time settings Using the dial knob and the confirmation button you can select and open the following options for setting the heat pump terminal Time settings Setting the hours day month and year of the heat pump clock in the format hh mm ss and dd mm yy Display Setting the backlight contrast and time interval to restore settings the default display if no operator action is taken Display Setting the content and order of the displayed parameters mapping Language Setting the language version of the heat pump control program selection Return Exits the heating pump terminal setting 41 Heat pump operation User level v 1 04 7 2 1 Setting the Real Time Clock This menu allows to set the time and date of the heat pump clock When the status line is displayed press the confirmation button to enter the main menu and use the dial knob to select the Setup option Menu Setup After opening this menu Setup moves to the top line of the display Use the dial knob to select
105. to the outdoor temperature but the goal is to achieve the required air temperature in the selected reference room Therefore in this case the time and manual temperature corrections adjust the air temperature in this room When the status line is displayed press the confirmation button to enter the main menu The bottom line displays Heating menu which allows you to start the heat pump Menu Heating After opening this menu Heating moves to the top line of the display and if the pump is switched off the display shows Heating Start After confirming the Start option the control board performs a check of the parameters and then starts the heat pump C F P TEL E DO 10 52 AT 2 4 CT 6 8 The top line of the display shows the status line Individual symbols for the compressor C the evaporator fan F and the circulation pump P are followed by symbols dashes which rotate in clockwise direction when the related parts run normally At the high tariff of the supplied electricity the characters C F and P are uppercase letters while at the low tariff they are lowercase letters The following indication TE1 determines the actually heated circuit this can be TE1 TE2 DHW or POOL the character E means the Equitherm control R means the Reference room and DO means the active Daily temperature correction according to the register 0 WO to W3 are Weekly temperature corrections according to the register
106. to the top line of the display Use the dial knob to select the Info option Setup Info After opening this menu Info moves to the top line of the display Use the dial knob to select the Current tariff times option Info Current tariff times After opening this menu you can view start times and durations up to four last time intervals with the high tariff An example when three recorded intervals with high tariff are displayed hh mm ddd hh mm ddd hh mm ddd where hh mm is the time of the beginning of the high tariff in hours and minutes and ddd is the duration of the time interval in minutes Press shortly the confirmation button to leave the menu 49 Heat pump operation User level v 1 04 7 3 3 Configuration and Program Version of the Heat Pump This menu allows to view the installed expansion modules program versions of each processor on the control board and serial number of the contro board When the status line is displayed press the confirmation button to enter the main menu and use the dial knob to select the Setup option Menu Setup After opening this menu Setup moves to the top line of the display Use the dial knob to select the Info option Setup Info After opening this menu Info moves to the top line of the display Use the dial knob to select the HW SW configuration option Info HW SW configuration After
107. top temp After opening this menu the display shows DHW stop temp XX Use the dial knob to set the required temperature in the range from 0 to 65 C After confirmation the prompt appears Save Y N XX Press the confirmation button to save the settings The confirmation message Saved OK briefly appears and then the display returns one level back Temperature settings HeW stop temp DHW Use the dial knob and the confirmation button to select and set the other temperatures or you can select and confirm the Return option repeatedly to exit the settings and return to the default state Setting the Start Temperature for Heating the Hew This menu allows to set the minimum temperature of the heating water in the HeW tank When the temperature drops below the set value the heat pump starts to heat HeW If the equithermal control requires a higher temperature than the preset start temperature the heat pump will maintain this higher HeW tank temperature regardless of the start temperature for heating HeW When the status line is displayed press the confirmation button to enter the main menu and use the procedure described in chapter 7 1 2 on page 28 to open the Temperature settings menu After opening this menu use the dial knob to select the HeW start temp option Temperature settings HeW start temp Hew After opening this menu the display shows HeW start temp HeW XX
108. tup option on the bottom line Menu Setup After opening this menu Setup moves to the top line of the display Use the dial knob to select the Terminal settings option on the bottom line Setup Terminal settings After opening this menu Terminal setup moves to the top line of the display Use the dial knob to select the Language selection option on the bottom line Terminal settings Language selection After opening this menu the set language version is displayed Language selection English Use the dial knob to select the required language version and press the confirmation button to save it Save Y N English Press the confirmation button to save the settings The confirmation message Saved OK briefly appears and then the processor reads the data corresponding to the set language version from the external memory This process can take a few seconds After loading the data the heat pump automatically restarts The initial test is performed and then display enters the default state showing the state line in the selected language Language version can only be selected from the predefined language pack which is programmed in the heat pump This pack can contain up to five language versions After loading the selected language version the test of its integrity is performed and when an error is detected the first language version from the language pack is automatically r
109. utdoor temperature AT Display mapping Mapping set 0 AT Confirm the selected temperature and a prompt appears Save Y N Mapping set 0 AT Press the confirmation button to save the settings The confirmation message appears Display mapping Saved OK Display returns one level back in the menu Display mapping Mapping set 0 Tx1 Use the dial knob to select the next positions 1 to 9 and A to F and assign them the required temperatures using the similar procedure After setting all the displayed temperatures leave the menu using the Return option Display returns one level back in the menu Terminal settings Display mapping 45 Heat pump operation User level v 1 04 You can select and confirm the Return option repeatedly to exit the heat pump settings and return to the default state The bottom line of the display now shows the temperatures assigned to the positions 0 and 1 You can use the dial knob to display the another temperatures on the selected positions List of the temperatures that can be displayed on positions 0 to F is shown in the following table AT CT CCT SUT IT OT DHW Hew EQ1 EQ2 POL SOL ET EOT Ambient outdoor temperature Condenser evaporator temperature Compressor cover temperature Suction temperature of the compressor measured at the evaporator outlet Reserve Inlet temperature water temperature a
110. y and the bottom line shows the first option for daily temperature corrections Daily View Using the dial knob you can select the following options for daily temperature corrections View This option allows to view and edit the daily temperature corrections stored in the current selected register Delete all This option allows to delete all the daily temperature corrections stored in the current selected register Activate This option allows to activate use the set daily temperature corrections to control the heating operation Return Exits the daily temperature corrections setting Viewing and Editing the Daily Temperature Corrections This option allows to view and edit the daily temperature corrections stored in the current selected register When the status line is displayed press the confirmation button to enter the main menu and use the procedure described in chapter 7 1 1 on page 14 to open the Heating settings menu Use the dial knob to select the option for temperature correction programming Heating settings Temp corr program After opening this menu use the dial knob to select the option for daily temperature correction programming Temp corr program Daily After opening this menu the display shows Daily View 297 Heat pump operation User level v 1 04 After opening this menu if the equitherm control mode is selected for the heating the di