Home

User`s Mnual

image

Contents

1. TE lt Load operation of nightlight model gt When battery is connected the output power is supplied to the load If charging starts the output power is off after 5 minutes You can check the load operation in this timing If charging stops the load will turn on about 10 minutes after A Vand M D TURN OFF the LOAD SUNRISE DAY SUNSET NIGHT TURN ON the LOAD SUNRISE WARRANTY Thank you very much for your purchase To make a claim under the warranty confirm the User s manual to be certain that there is a problem with the product 1 Please keep your warranty document safe Without a valid warranty you cannot accept a warranty service Upon modifying contents of this warranty document the document is deemed to be invalid 2 DENRYO CO LTD warrants original purchase against defects in material and workmanship for a period of THREE 3 years from Shipment Date to buyer The extention shall in no case exceed THREE POINT FIVE 3 5 years in aggregate 3 DENRYO CO LTD shall not warrant product under the following conditions Damage by accident negligence at operation incorrect directions for use E g Damage by not using with the exact way User s manual and original label say Damage by other devices are connected to our product Unauthorized remodel by other than our serviceperson Breakdowns due to the effects of natural disasters pollution
2. n PE OFF OFF 30 OFF OFF Over D S Load OFF OFF i 50 ON ON CS oe YEL Temp OFF ON Low 20 ON ON YEL tas ON OFF High Voltage LED Solid The battery voltage has exceeded the maximum regulation limit of the controller Make sure the battery is applicable Over Load LED Flashing The load current exceeds the maximum load current rating The Load is reconnected automatically by every 3 seconds in 10 minutes If the overload remains LED becomes solid and disconnects x1 Solid There is a possibility of load wiring short circuit The fault must be cleared by removing and reapplying power High Temperature LED Flashing The controller temperature has become high The bulk charging current is limited to 80 gt lt Solid The controller temperature had become high The controller stop charging until the temperature becomes low Low Voltage LED Flashing The battery voltage is low Solid The load is disconnecting for Low Voltage Disconnection The load will automatically switch on when the battery recharges to the Low Voltage Reconnect threshold voltage 5 Safety Information 5 1 DO NOT short circuit AN 5 3 Explosion hazard O 5 2 Protect from direct rain Non invertible Non flat 5 6 DO NOT reverse polarity connection 5 5 Positive earth ground 8 Specifications Normal model SA BA10 SA BA20 SA BB10 Nightlight mode
3. salt damage Lack an original label includes serial number Made a claim after passing warranty period Damage by any transactional problems not attributable to DENRYO CO LTD E g Damage by accident during transportation without other than our packing 4 Buyer shall bear the shipping charge when return the defective products DENRYO CO LTD IS NOT RESPONSIBLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY KIND INCLUDING BUT NOT LIMITED TO LOST PROFITS DOWNTIME GOODWILL OR DAMAGE TO EQUIPMENT ORPROPERTY CY DENRYO DENRYO CO LTD Model Name SA BA10 SA BC20 SA BB10 28 5 Nishinippori 2 Chome SA BC10 SA BC20 SA BD10 Arakawa ku Tokyo Sreial No 116 0013 Japan TEL 81 3 3802 3671 Dealer FAX 81 3 3802 2974 Email info en denryo com Website www denryo com DM 4709 Sale Date a yyyy mm dd
4. Cf DENRYO Solar Charge Controller Solar Amp User s Manual Ver 1 03 C RoHS 1 Introduction Thank you for purchasing SolarAmp B solar charge controller This manual contains important safety installation and operating instructions for SolarAmp B solar charge controller in order to prevent the users from any damage Make sure to read all of the instructions and cautions in the manual before beginning installation DENRYO CO LTD 2 Product Overview SolarAmp B is very compact design and very simple to use which has full electronic protections lt Product Line up gt Normal model Load Always ON SA BA10 SA BA20 SA BB10 Nightlight model Load Dusk to Dawn SA BC10 SA BC20 SA BD10 7 Operation 7 1 Appearance SolarAmp CE MAYO a 2 MO 8 14 2 7 2 State of Charging LED LED Color Indication Status k g s Flashing Charging Solid Full Battery Charging Charging LED Charging LED is flashing while charging the battery Flashing LED becomes solid when the battery is full charge 3 Features 3 stage Charging Bulk Absorption Float Discharged Battery Recovery Full Electronic Protections High Voltage Protection Over Discharge Protection Over Load Protection High Temperature Protection Reverse Polarity Protec
5. l SA BC10 SA BC20 SA BD10 System Voltage 12V 24V Max Input Voltage 25V 50V Min Input Battery Voltage 6V 8V Max Input Current 10A 20A 10A Max Load Current 10A 20A 10A 2mA Typical 3 stage Bulk Absorption Float Model No Self consumption Current Charging Algorithm Charging Voltage 14 4V 28 8V Float Charging Voltage 13 7V 27 4V High Voltage Protection 18V 36V Over Warning 11 8V 23 6V Discharge Error 11 5V 23V Protection Recovery 12 5V 25V 60 C Warning 80 C Error 60 C Recovery Battery Type Lead Acid Battery Wire Size 12AWG to 18AWG 10AWG to 12AWG 12AWG to 18AWG High Temp Protection Grounding Positive Ground 30mv C 20 to 60 C 80 to 70 C Humidity 5 to 95 RH non condensing 29x91 x 55mm Weight 65g 70g 65g C RoHS This Document must not be copied photocopied reproduced or converted to any electronic or machine readable form in whole or in part without prior written approval of DENRYO CO LTD C 2013 2014 DENRYO CO LTD All Rights Reserved 60mV C Temperature Coefficient Operation Temperature Storage Temperature Dimensions D x W x H Certifications 6 Connection Connect each wire in order 1 LOAD 2 BATTERY 3 PV panel as the below figure and screw tightly not to loosen Cf DENRYO HA a i BATTERY G
6. tion Load Short Circuit Protection Surge Protection Current Regulation Caused High Temperature Positive Earth Ground Status LED Indications State of Charging High Voltage Over Load High Temperature Low Voltage 4 Precaution Cover the PV panel Photovotaic panel Solar panel with cloth not to generate electricity during installation It is recommended to install an external fuses less than rated current between controller and battery controller and load Connect battery to earth ground if necessary positive earth ground If you need negative earth ground connect only one terminal battery or PV panel or load terminal to the earth ground Do not connect device which has big input capacity such as DC AC inverter to the load terminal Do not use PV panel or Load which specification is out of the ratings The PV panel Voc should never exceed Max Input Voltage of the product The PV panel Isc should never exceed Max Input Current of the product The peak current of Load should never exceed Max Load Current of the product Charging will start when PV panel voltage exceeds battery voltage Reverse Polarity Protection and Over Load Protection is not effective in every possible condition thus please take care in wiring and confirm the specifications of PV panel and Battery and Load 7 3 Warning and Error LED LED Color Indication Charging Status Load Status 7 High

Download Pdf Manuals

image

Related Search

Related Contents

Manual del Usuario - YAMAKI sonido profesional  Nikon 6mm User's Manual  Manual de instalación para módulos solares  Programación Aplicada y Lab. - Coordinación de Ingeniería en  Bedienungsanleitung für das Bull's Dartforce - Get  Manual Del Propietario  Workforce Supply Assessment Tool user guide  GE AHG50LB / AHG50LD Dehumidifier  Samsung S22B360HW 用户手册  

Copyright © All rights reserved.
Failed to retrieve file