1. character 7 The pwd in the commands is means the password when you use it please instand of it by the digital number the capital letters PWD is the command letter use PWD directly 8 If you use this model for gate open you only need to change the password and setup the authorized numbers 9 In some GSM operators they use different SMS parameter the units can t return the SMS confirmation is normal is not product problem 10 Please write down the Authorized number list in a paper for review in further 11 The SMS commands that you will certainly use in the GSM Gate Opener are the following 6 1 Setup New Password if successful the unit will return Password modified OK For example the original password is 1234 you want change it to 6666 then you can send the command below 11234 PW D6666 PW D66664 6 2 Setup Authorized number E g if you want to setup 13570810254 as the first user number and the password is 1234 then you can send 1234 TEL13570810254 01 to the G Auto unit Tips 1 the authorized number means the one who can dial the G Auto unit to open it 2 We strongly recommend that the serial number of 01 and 02 are cellphone number because of the alarm message only send to the first and second position numbers 3 The Serial Number is the position to store the authorized number from 01 64 6 3 Inquiry the Serial Number s Authorized number E g If you want to know the authorized number at posit
2. 1 1 File No G Auto www securitywireless co za 1 Brief introduction The GSM Gate Opener G Auto is a very simple device which can be used for authorized door access controlling gates switching of remote equipments car parking systems Actually the GSM Gate Opener G Auto can be used in places which require to turn ON OFF your system machines equipments remotely with a FREE call from your mobile phone and protect your assets Just dial from Authorized User number then the Barrier and doors are opened or the machine are turn on or off by the GSM Gate Opener There are no call costs the GSM Gate Opener rejects the call from authorized number then carries out the turn ON OFF action Moreover the G Auto with 2 digital inouts for digital inouts when any one of the inputs triggered will start the siren or switch on the light in the meanwhile the G Auto will send SMS Alert the to owners immediately This is very useful if you need protect your assets with low cost solution 2 Safety Directions Safe Startup Do not use GSM Gate Opener when using GSM equipment is prohibited or might bring disturbance or danger Interference All wireless equipment might interfere network signals of GSM Gate Opener and influence its performance Avoid Use at Gas Station Do not use GSM Gate Opener at a gas station Power off GSM Gate Opener when it near fuels or chemicals Power it off near Blasting Places Please follow relevant restrictive regul
3. ations Avoid using the device in blasting places Reasonable Use Please install the product at suitable places as described in the product documentation Avoid signal shielded by covering the mainframe Use Qualified Maintenance Service Maintenance can be carried out only by qualified maintainer Page 3 of 11 Wireless alarm PageS3of1i Ver 1 1 File No G Auto www securitywireless co za 3 Standard Packing List Control Unit X1 GSM ANT X1 User Manual X1 Connetor X1 Optional Accessories Wired Sensors PIR Motion Sensor Glass Break Sensor Magnetic Window Sensor Temperature Sensor Infrared Beam Fence Vibration sensor Siren 4 Physical Layout 4 1 Control Unit physical layout eee Relay GSM Power GSM Gate Opener GSM Remote Controller Open gate or garage door with a FREE call Remote switc hing machines with a FREE call 12VDC gt zZ Interface Instruciton Relay Status calling in the relay will work this LED Indicator will on When the wired sensor triggered the LED indicator will on Otherwise is off When insert the SIMcard into the Solt will flash per0 5S with red color When registered GSM Network successful will flash per 0 58 with Yellow color When calling in the relay works will flash per 0 58 with red and yellow color External 12VDC Power LED indicator O1 Output 1 the relay rating is 3A 240VAC connect to the switch of the lock or devices Output 1 the relay rat
4. ing is 3A 240VAC connect to the switch of the lock or devices Page 4 of 11 Wireless alarm Page4of11 Ver 1 1 File No G Auto www securitywireless co za Siren connector connect to the Siren Positive lf need the siren start when the sensor triggered must connect this connector with 12VDC connector If not use the siren then needn t connect it Connect to the NA Point when sensor triggered will start the siren for 90Seconds 12VDC Also it can be connected to wired sensor to supply 12VDC power for sensors if need Common connect to Siren Negative another wire of the two wired sensors Digital input 1 connect to one wire of the first wired sensor Digital input 2 connect to one wire of the second wired sensor 12VDC The external power input 12VDC 1A 5 Features 1 No call charges the GSM Gate Opener rejects the call from authorized number then carries out the turn ON OFF action on the first ring 2 Multiple applications gates bollards barriers garage doors shutters and access doors or machines Secure Using caller ID for identification unknown callers are ignored Can be operated from anywhere no distance limit Add or remove users by SMS Text command No need to provide a remote control for different users Up to 64 authorized phone numbers can be configured Two Digital inputs for door sensor motion sensors or other sensors to protect your door and windows when any one of them triggered
5. ion 2 and the password is 1234 then you can send 12344 TELO2 ito check it 6 4 Remove the Authorized Number Page 6 of 11 Wireless alarm Page6ofi1 Ver 1 1 File No G Auto www securitywireless co za or you can overwrite with another number you wish to change it E g if you want to remove the authorized number at position 12 and the password is 1234 then you can send 1234 TEL 12 6 5 Disable the digital inputs Deflaut is disable Tips if you want to use the digital inputs please enable it firstly 6 6 Enable the digital inputs Tips if you enable the digital inputs function the sensors will enter Armed status after 10minutes of the lastest dial in in the first 10minutes when the sensor triggered will not alarm after 10minutes the unit in armed mode when any sensor triggered will start the siren if you connected or switch on the light if you connect it and send SMS to the Position 01 and 02 authorized numbers immediately This function is very useful for garage or other applications It can protect the assets for you by GSM Network 6 7 Inquiry Alarm Setting Reply Disable Aalrm jor Enable Alarm Tips Disable alarm means disable the digital inouts Enable alarm means Enable digital inputs 6 8 Setup allow all calling in numbers can access it Tips This command allows anybody calling the SIM number to access it Warning with the above command you allow free access to anybody calling 6 9 Setup only a
6. onnecting the Electronic Lock or Electricity equipments Page 9 of 11 Wireless alarm Page9of11 Ver 1 1 File No G Auto www securitywireless co za O1 01 Siren NA 12V gt Int In2 12VDC 220VAC 220VAC aw az ae Se 7 4 Install the Mainframe The mainframe should be installed in the postion that person can not get it and there re with a power source as well as enough GSM signal coverage 8 Technical specifications Rated Voltage 12VDC1A Page 10 of 11 Wireless alarm Page10of11 Ver 1 1 File No G Auto www securitywireless co za Working temperature 10 C 60 C Storage temperature 20 C 60 C Relative humidity 10 90 No condensation Work frequency 900 1800MHz Communication protocol GSM PHASE 2 2 include data service Wired Zones 2 Related Voltage of the Output Relay 3A 240V AC Net Weight 0 50Kg 9 Important information _ Please read the User Manual carefully before you install the Control Unit and set the Control Unit 2 Install the system in a hidden place 3 Avoid getting water into the Control Unit 4 Have a secure connection to the main power supply 10 Maintenance 1 Incase of failure please contact the distributor or manufacturer 2 If the remote control works but the Control Unit fails to send SMS texts switch the power of Control Unit off and switch it on after one minute Test this system after another minute or check the setting
7. s are correct and the GSM Signals are strong enough 3 If the Control Unit can run and sensors work but cannot send SMS texts please change SIM Card to check it 4 Ifthe problem cannot be solved please contact the distributor or manufacturer 11 Warranty 1 This system is warranted to be free of defects in material and workmanship for one year from the date of purchase 2 This warranty does not extend to any defect malfunction or failure caused by abuse or misuse by the Operating Instructions In no event shall the manufacturer be liable for any alarm system altered by purchasers The End Any questions please help to contact us feel free Email Us info securitywireless co za Hitp www securitywireless co za Hitp www securitywireless co za Page 11 of 11 Wireless alarm Pagei1ofi1 Ver 1 1 File No G Auto
8. type Tips when you set the digital inputs as NC if you don t use the input please connect the digital inputs by a wire to short it Otherwise it will alarm E g if you only use the input 2 then you should use a wire to connect the input and GND point to make it as Normal Close Modify the digital input type as NO if the sensor you used with this unit is NO the you should set the unit as NO type The default is NO 6 12 Check GSM signal quality Check GSM signal quality This command is useful to see what is the GSM network signal level your GSM Gate Opener is receiving If you send the command You should receive a SMS with signal quality in range 0 to 32 if it is O we doubt it will ever answer You should have a signal above 12 to be sure of being able to open the gate in any condition Better if above 16 You should add an external GSM antenna if this is not the case or eventually even change operator with another that serves your area better 6 13 Enable return SMS confirmation when Relay action Tips if you enable it when the relay action close or open the unit will return a SMS confirmation to you You can disable it by the following command pwd N deflaut is no return SMS confirmation when relay action This is very useful when you use the G Auto to control the equipments remotely To check the settings you can use the command jpwd M it will return Retrun SMS or Not Retrun 6 14 Modify the Alarm SMS message
9. uthorized number can access it Deflaut Tips With the above command you allow only people that are in the authorized number list can access the G Auto This is the standard and recommended option Inquiry this setting Relpy Allow all numbers can access it or Allow User Number can access it only 6 10 Setup the relay close time Tips The time should be in 0 9 5seconds This command is useful in case you need to keep the relay closed or button pressed longer The deflaut time is 0 5seconds 500 ms You can change it with the GOT command The relay colsed Page 7 of 11 Wireless alarm Page 7of11 Ver 1 1 File No G Auto www securitywireless co za time is twice as the number you set e g if you set pPwd GOT19 means the relay closed 19 2 9 5Seconds To check the value you can use the command jpwd GOT the unit will reply the current value If you want to let the relay always closed until you call it next time then you can set the time as 00 the format is jpwd GOTOO the relay will be always closed untill next time call in in this case only the 1 24 3rd authorized number can access it The other authorized numbers can not access the unit This is very useful for remote switch on or switch off the electricity appliance or equipment or device for a long time 6 11 Modify the digital input type Modify the digital input type as NC if the sensor you used with this unit is NC the you should set the unit as NC
10. when inputs triggered The user can modify the digital inputs alarm SMS message by the following command the SMS Alert Page 8 of 11 Wireless alarm Page8of11 Ver 1 1 File No G Auto www securitywireless co za message should less than 30 letters When the sensor triggered these SMS message will send to the Position 1 and Postion 2 cellphone numbers to alert the user the default SMS Alert message is Door Open Alarm The above command is use to modify the digital input 2 alarm SMS text message PWG TEXTZO000000000003 the digital input 1 alarm SMS text message E g Modify the digital inputi alarm SMS Text message as Left Windows Open If the password is 1234 then you can send Tips 1 This command includes two 2 The xxxxxxxx in this command is indicates the message contents 3 The TEXT1 is part of the command refer to the input 2 message 4 The TEXT2 is part of the command refer to the input message 7 Installation Before installing the contro unit and sensors and sirens please help to test the system firstly including wired sensor power supply gsm signal etc 7 1 Insert SiMcard into Control Unit In the backside of the control unit please install the GSM SIM card 7 2 Connecting the Wired Sensors Please help to see below wiring diagram then fixed the related wired sensors the sensors connect to the related digital inputs the siren should connect to the Siren and Com connection port 7 3 C
11. will send SMS alert message and start the siren immediately 9 One output with relay rating 3A 240VAC for connecting the switch of the door or machines 10 The relay action will return a SMS confirmation to the owner this function is editable by user 11 Based on GSM Network applied to many applications oo oe a 6 Settings 1 The deflaut Password is 1234 2 All the settings are through SMS commands please edit the below SMS commands in your cellphone then send to the G Auto Unit 3 You can program the GSM Gate Opener with SMS commands using your phone It is safe to do so because in addition to the fact that other people may not know the number of the Page 5 of 11 Wireless alarm Page5of11 Ver 1 1 File No G Auto www securitywireless co za SIM inserted in it we also use a Password that makes it impossible for anybody who doesnt know it to access the system by chance 4 The relay output will change the close or open status by every call in please note it Means the first time call it it will close the relay to switch on the lock if the second call in is in the setting time then the unit will ingore the setting time and open the relay to switch off the lock or machine 5 The functions of the two inouts are the same The two digital inputs will be in armed mode after 15minutes from the last call in 6 Remember that commands must be CAPITAL LETTERS It is PWD not pwd CAP not Cap etc Don t add spaces or any other
12. www securitywireless co za GSM Gate Barrier Shutter Garage Door and Door opener Open gate or garage door with a FREE call from your mobile phone Remote switching machines with a FREE call from your mobile phone Relay GSM Power GSM Gate Opener GSM Remote Controller Open gate or garage door with a FREE call Remote switc hing machines with a FREE call gt 12VDC GSM Gate Opener GSM Remote Switch G Auto User Manual Ver 1 1 Date Issued 2009 12 18 All rights reserved by Wireless Alarms Website Http www securitywireless co za Page 1 of 11 Wireless alarm Page1of11 Ver 1 1 File No G Auto 10 11 www securitywireless co za Table of contents Brief introduction 2 Safety Directions 3 Standard Packing list 4 PIYSICAN LAVOUL se e 4 fr UG esas cies eee 5 Settings 5 TRE CLE on e e g Technical specifications 9 Important information 10 Maintenance 10 Quality Warranty 10 Page 2 of 11 Wireless alarm Page2of11 Ver