Home
HDSM USB-USB Plus - Horizon Global Electronics Ltd
Contents
1. USER MANUAL HDSM USB and USB PLUS Horizon Digital Satellite Meter HORIZON sr USB DIGITAL SATELLITE METER C Issue No KM996 1 3 Horizon Global Electronics Ltd www horizonhge com Horizon Part Number KM996 Contents Safety Page 2 Accessories Page 3 Your Meter Page 4 Battery Charging Page 5 Using Your Meter Page 6 HDSM USB Sub Menu Page 8 HDSM USB Sub Menu DiSEqC Page 11 USB Driver Installation Page 14 Transferring Data Page 16 FAQ Page 17 Specifications Page 18 User Notes Page 19 Warranty Page 22 Manufacturer s Statements Back Page Thank you for choosing to buy the Horizon Global Electronics HDSM USB USB PLUS satellite meter Please read through the instructions carefully before using your meter to familiarise yourself with all of the new features available The HDSM USB USB PLUS is a compact lightweight and easy to use satellite installation meter featuring an easy to read display that shows signal strength and digital signal quality Finding your satellite is easy use the left or right arrow keys to scroll through the selections and your HDSM USB USB PLUS will lock onto the satellite shown in the display when it is in range Everything you need is supplied with your meter which includes a mains charging lead in car charger and USB lead The rain cover and leather case are already fitted The HDSM USB USB PLUS can also be easily re programmed from the Horizon Global Electronics website www horizonhg
2. are ROHS compliant Technical Department Horizon Global Electronics July 2007 CONTACT DETAILS Horizon Global Electronics Ltd Unit 3 West Side Flex Meadow Harlow Essex CM19 5TJ Tel 44 0 1279 471 005 Fax 44 0 1279 417 025 Email sales horizonhge com Web www horizonhge com Producer ID for the purposes of WEEE regulations WEE BB0191UV
3. t E0 60Hz manual HORIZON 22 HDSM WARNING Serial number 9512xxxxxnn SHOCK HAZARD DO N EN TO PREVENT SHOCK BO NOT REMOVE COVER puis rh BLE PARTS INSIDE DO NOT EXPOSE TO RAIN OR MOISTURE AC SUPPLY 100 240V Before replacing 0 31A MAX battery please refor t 50 60Hz manual Manufactured in the U K Manufactured in the U K Battery Cover AN NiMH Battery fitted Only use Horizon replacement batteries Tamper Proof Warranty Label Side View Rear View D ru Input AC Mains Charge Input Enon age 4 100 2407 0 31A MAX 50 60HZ DC Charge lt lnput 12V DC 0 8A Page 4 Battery Charging The meter will NOT be fully charged when you receive it We recommend you charge it for an initial 24 hours before use If your meter is not being used for a long period of time we recommend disconnecting the battery The battery pack is replaceable To replace the batteries slide the meter out of its protective case open the cover on the bottom of the unit and disconnect the batteries If the pack has been disconnected the meter will indicate flat battery 0 You will still be able to use the meter in this state if the battery pack has been charged To restore the correct charge reading charge as shown below until Trickle or Float Charge is indicated You can also top up your battery from your vehicle with the DC Adapter supplied Charging with the mains lead On
4. the bottom of the case there is a small velcro flap which covers the AC Mains input for charging Charging from a vehicle The vehicle 12V DC charge port is on the right side of the unit Plug the car charger lead into the bottom socket and the other end to the vehicle s aux socket Please note that on certain vehicles the aux socket is switched off unless the vehicle is running For in vehicle charging only use the lead supplied The use of another lead may damage the meter and will void the warranty The HDSM can remain connected to either power source in Trickle charge state for an extended period of time If the meter is left on charge for over 24 hours the meter will switch to Float Charge this is a low cycle charge state and the meter can remain on charge without damaging any internal components or the battery pack Note The meter will not operate while the unit is being charged Page 5 Using Your Meter SI The HDSM USB USB PLUS keypad All of the meter functions are accessed from here Once your dish mounting has been securely installed in a suitable direction connect the LNB to your HDSM meter with a short length of cable 1 5m or 4 feet being ideal note that this cable is not supplied you should use a high quality satellite cable such as CT100 Tip Your dish clamp should be just nipping the metal work allowing you to adjust the dish position and it should hold when you release To tu
5. transponder Frequency in MHz this is the measured frequency after pull in by the meter s AFC so the displayed value may differ slightly from the nominated value in the configuration file Symbol Rate in kiloBaud kiloSamples Second the data rate is critical in identifying and locking to the selected carrier FEC forward error correction value data on the selected carrier will conform to one of a short list of standard FEC values IQ Norm indicates that no IQ Swap is not present At bottom right there is a display of the charge state of the battery pack Tip The constellation diagram can be used down stream from the LNB to trace problems caused by faulty components that introduce noise and affect the quality of the digital signal 10713MHz 22000kBd This illustration shows how a typical FEC 5 6 QPSK constellation diagram would IQ Norm be represented TE Note The following feature is only available on the HDSM USB PLUS Histogram function 12345 6 7 89 The HDSM USB PLUS also has an additional feature of 80 a histographic display this can be used in SCR Single 70 Cable Router environments to measure up to 9 different 60 frequencies simultaneously Settings for this function can be downloaded from the Horizon Global Electronics web site The scale on the right hand side of the display gives an indication of level in dBuV Note The histographic function can only be selecte
6. website ee gt amp Product 0 Buehner Geese ee teen Serial Number 2 ccc ccereccccce ccc cncceecccccsecccceceeecccecsecccceeeecces Date Of Purchase sareni ean ar a a a BUVErSINAME a E E E ee ese COMI nn e a eae EEEE ee PRONONCE TS aa e a a e E Email AOC SSSR se ee a eee E E Address rence ec ce ce ccc cee ce cee ce ccc nun nn nun cece ce ccc cccccccccecccee Horizon Global Electronics Ltd Unit 3 West Side Flex Meadow Harlow Essex United Kingdom Phone 44 0 1279 417005 Fax 44 0 1279 417025 Email sales horizonhge com Web www horizonhge com ee di ee ee ee ee ee ee ee ee ee 4 Page 22 LIMITED WARRANTY Horizon will at our option repair or replace any HORIZON Digital Satellite Meter found to be defective in manufacture within the warranty period 1 year The warranty period is determined by the date of HDSM purchase Keep your receipt as proof of purchase Otherwise the warranty is determined by date of manufacture This warranty does not apply to damage caused by accident misuse or tampering with the unit or seals This does not affect your statutory rights DECLARATION OF CONFORMITY Manufacturer Horizon Global Electronics Ltd Address Unit 3 West Side Flex Meadow Harlow Essex CM19 5TJ Declares that the Horizon Digital Satellite Meter HDSM USB USB PLUS complies with the following directives and standards safety EN610 10 1 2001 EMC 61326 1997 All Horizon products
7. B USB PLUS is only compatible with DVB QPSK modulated carriers and will not show a lock on other types of modulation such as DigiCipher DVB S2 8PSK or turbo encoded services When using lower symbol rates less than 04000 it may take a few seconds to obtain a lock and it will require much slower motion when pointing your antenna Tip Common carrier configurations can result in a multiple lock situation For example carriers that have an FEC of 3 4 and a Symbol Rate of 27500 will probably lock on multiple satellites Where possible look for unique Symbol Rates that are unlikely to be duplicated on other satellites at the defined frequency LNB Cable Test The LNB Cable test is a quick function to check for possible fault conditions and will indicate if there is a problem LNB Cable test The test results will appear after a few seconds as indicated in the table below Please wait LNB Cable OK LNB Fault Exit LNB Cable Fault Note The above function is for indicative purposes only Page 10 HDSM USB Sub Menu DiSEqC The DiSEqC Switch functions are available from the sub menu of the HDSM USB and USB Plus Exit DiSEqC Custom Carrier Recall Custom LNB Cable test Exit Options Dual Horn SMATV switch Exit 4 Pos Switch Dual Horn SMATV switch Exit 4 Pos Switch Options SMATV switch From the sub menu DiSEqC function shown here you can select a variety of DiSEqC switch commands to s
8. Global Electronics Download website for HDSM for updates or to create your preferred list Go to www horizonhge com Please follow the steps illustrated below to upload new selections to your meter 1 Wait for the HSDM USB USB it PLUS to display Program ee Mode while establishing Cable 1 A communication the display el may flash and the sounder Program Mode 1 B 0 may beep This is normal E ES Li 3 Horizon Satellite Meter File ComPort Transfer Help lt gt Horizon Satellite Meter File Mae ces 2 Ensure that USB is ticked on the ComPort drop down menu as shown Transfer Help COMI COM COM COM After a few seconds a progress bar will appear Then click Transfer When complete you will see a popup window that says Transfer Complete Click OK and close the e program Jj Transfer Complete Horizon Satellite Meter fx Disconnect the meter from the computer power it up and it will be ready for use Trouble shooting file transfer problems x lt gt Horizon Satellite Meter File Re Transfer Help COMI COMe2 COMA od If you receive a Serial Interface error If you get this error message Error Ack Not Received Check that the USB interface check your COM port selection and select the correct COM port USB connection is correctly made and that the USB cable is undamaged Page 16 FAQ Ack Not Received Error 1 Incorrect Com Po
9. TILL Page 6 Using Your Meter Setup Menu Continued To access the Setup Menu ensure your HDSM USB USB PLUS is off and press the UP key once The following options are available from this menu Backlight on By using the keypad as cursor keys you can navigate Clicking on through the set up menu using UP and DOWN and Brightness 10 change values by using LEFT and RIGHT keys Once you have made your selections return to the top of the Contrast 31 menu highlighting Exit and press the left or right key to Sleep 6M apply the changes and switch the meter off English AT CSUN Y back to the default setup by selecti re 7 ou can also go back to the default setup by selecting BER x xxE x Defaults This operation will not affect any of the BER Log satellite settings stored in memory C N LNB 13V 18V Defaults 1 0Ba 0030 n b The full menu is shown here whereas only four options are visible at any one time on the LCD display Alternative languages are available for menu items and on screen information The RF can be displayed in either dBuV or Linear modes The BER numerical display can be changed so that Found only is displayed BER can be measured in Linear mode for better sensitivity or Logarithmic form The 1 0Ba 0030 reference may vary it is for Horizon use only and does not affect any meter functions The HDSM USB USB PLUS supports many languages selectable from this menu page English French Spanish I
10. ar scale 256 steps Feature available in setup mode Input impedance 75 Ohms Symbol Frequency rate from 1Msps 45Msps C N carrier to noise is displayed in dB Signal Strength and BER displayed together The Quality indicator pre BER or bit error rate locks on faster making it easier to identify the satellite initially typically locks in less than 100mS Instead of Found to indicate the lock on correct satellites the actual BER can be displayed This Feature is available in set up mode Audible and visual tune in with selectable and adjustable display backlight and contrast Spares for your meter Description Part Numbers A Rain Cover ARSUSB A Car Charge Lead AW992CIG 2 Amp Fuse F CF2AGQB A Battery Pack Ni MH 7 2V 3 3Ah BP7233 2 USB Lead AW998 USB Leather Case ALOO1BK Page 18 User Notes User Notes Page 20 User Notes Warranty Thanks for taking the time to fill out your warranty card Horizon will at our option repair or replace any HORIZON digital satellite meter found to be defective in manufacture within the warranty period 1 year The warranty period is determined by the date of the HDSM purchase Keep your receipt as proof of purchase Otherwise the warranty is determined by date of manufacture This warranty does not apply to damage caused by accident misuse or tampering with the unit or seals This does not affect your statutory rights The warranty card is available for download from
11. are provided with the software as a printable PDF document Page 12 HDSM USB PLUS Menu Continued Note The following additional features are only available on the Sub Menu for HDSM USB PLUS Constellation diagram Provided the meter is locked to a DVB QPSK modulated carrier Constellation mode is available from the Sub menu press the UP button while the signal level or carrier noise display is on screen If there is no lock the option will be greyed out This type of diagram is almost meaningless when it cannot display formatted QPSK data dots would appear randomly in each quadrant and there would be no visible pattern In the Sub menu scroll down to highlight Constellation and press the RIGHT arrow The screen will change to the QPSK constellation display and a listing of the current transponder settings The graphic displays the 4 quadrants of a QPSK signal A good display will show a cluster of dots towards the outer corner of each quadrant The more concentrated the cluster the better the quality of the received signal dots straying from the cluster indicate noise on the signal phase errors and other unwanted artefacts The aim is to achieve the best result possible which a thorough alignment of the LNB should achieve With the constellation diagram you get reassurance that the adjustments have been done well At the right side of the screen is a list of the parameters for the currently chosen
12. d when downloaded as an additional setting Page 13 USB Driver Installation Found New Hardware Wizard Welcome to the Found New 1 Connect the meter for the first time to a PC Hardware Wizard equipped with USB port s If the USB drivers don t automatically load then the Found New Hardware Wizard will appear Select Yes this time only Windows will search for current and updated software by looking on your computer on the hardware installation CD or on the Windows Update Web site with your permission Read our privacy pobcy Can Windows connect to Windows Update to search for software Yes this time on C Yes now and every time connect a device Then click Next C No not this time Click Next to continue Next gt Cancel ound New Hardware Wizard F Welcome to the Found New Hardware Wizard This wizard helps you install software for Select Install the software automatically USB Serial Port Then click Next If your hardware came with an installation CD gt or floppy disk insert it now What do you want the wizard to do Install from a list or specific location Advanced Click Next to continue crea i Found New Hardware Wizard Please wait while the wizard searches Horizon HDSM 3 While your PC is searching for the gt 2 DRIVERS a window like this will appear 4 Found New Hardware Wi
13. e com with your choice of satellites or with the default file for your region Spare battery packs are available directly from Horizon Global Electronics and can be replaced without voiding your warranty Replacement leather cases rain covers USB leads mains charging leads and in car chargers are also available directly from Horizon Global Electronics Ltd Page 1 Safety Safety Instructions AN This symbol is intended to alert users of possible hazard or damage in operating this unit e Do NOT expose this meter to rain or moisture e Clean only with a dry cloth e Always use the protective case and cover provided e Read the instructions fully before operating your unit for the first time e Care should be exercised when using the carry strap as it can present a choking hazard only use when slipping or falling is not a possibility e Do not disassemble your unit or interfere with the internal components this will void your warranty and there is a possibility of electric shock If the equipment is used in a manner not specified by the manufacturer the protection provided by the equipment may be impaired e Only use the provided battery mains lead and DC car charger lead provided as using other types AN may cause damage to your unit which will void your warranty and may cause electric shock Replacement battery packs are available directly from Horizon Global Electronics Ltd Should repair or service be required co
14. evel or carrier noise display is on screen Scroll down to highlight Spectrum and press the RIGHT arrow The screen will change to display the spectrum The graphic will be centred on the frequency of the selected transponder in our example of a Low Band setting the display is centred on 10728MHz The span range of frequencies displayed on screen is set by default to 240MHZ which gives a display of 8 adjacent carriers at 30MHz spacing By pressing the DOWN button you can cycle through a range of spans from 60MHz to zoom in on one carrier in particular to 1200MHz Centre the chosen frequency on the display by pressing the LEFT and RIGHT buttons Note that you will not be able to go beyond the limits for each band which are indicated by arrows pointing right lowest frequency or left highest Note that the Low Band coverage extends from 10700MHz to 11600Mhz and the High Band from 11550MHz to 12750MHZ so there is some overlap between the Low and High Band for Universal LNB s RF level is shown by a solid band at each sampled frequency see image There will be areas of low level signal between the carriers and the bigger the distance between peaks and valleys the better the carrier to noise ratio Good C N ratio is important for trouble free reception The top line of the screen alternates between Centre plus the selected frequency shown at the dotted vertical line in the centre of the display and Span plus the fre
15. for its operational requirements Here we can select IQ unswapped Norm or Swap Sometimes IQ Swap is required to obtain a lock but for most of the time this is left selected to Norm Normal use the Swap selection if you failed to obtain a lock so far Press the right arrow key to step onto the Save and Exit screen once you have made your selection Continued HDSM USB Sub Menu Continued Using the Custom Carrier feature Now that all of your parameters have been set you have the option to save your custom carrier to memory that s separate from the predefined selections Save and Exit y Pressing the DOWN arrow on this screen will save your custom carrier to SOO memory and exit to searching mode where you can now use your S Pe ee ee DEP ee EP A OcByu custom carrier settings to find the desired service If you prefer not to Searching save your settings press the RIGHT arrow to step on to the Discard screen If you wish to use your custom carrier at a later installation this IT can be recalled by using the Recall Custom option from the sub menu Discard v By pressing the DOWN arrow on this screen all of the values you S PETTITT OcByu have set will be discarded and the meter will return to searching Se ee mode on the last satellite selected before entering Custom Carrier Searching mode Alternatively use the RIGHT button to cycle through the custom carrier options to set another carrier of your choice LR Note The HDSM US
16. i OSD Searching E LNB Horiz 18V S i OcBu Searching E IQ Norm S aai OBH Searching E Page 9 You can set the desired frequency by using the UP and DOWN arrow keys to change the highlighted number and LEFT and RIGHT to step to the next one Once you have your desired frequency press the right arrow to step on to the Symbol Rate screen Note that you will not be able to select out of range values e g 20700MHZ in Ku band mode In much the same manner that you defined the frequency set the Symbol Rate to match the wanted signal highlight the numbers with the LEFT or RIGHT key and change the value with the UP and DOWN arrow keys Symbol rates from 01000 to 45000 can be set Once you have the desired symbol rate press the RIGHT arrow to step on to the FEC screen From this screen we can select the desired FEC If the FEC is unknown then select Any and the HDSM USB USB PLUS will try them all when searching from the Custom Carrier The FEC s available are show in the table to the right Press the RIGHT arrow to step on to the LNB voltage screen On this screen we can select the LNB voltage 18 Volts for Horizontal or 13 Volts for Vertical Press the RIGHT arrow button to step on to the IQ screen Note If you are using a block type LNB for VSAT installation 18 Volts is typically selected to power this kind of LNB as the polarisation is manually adjusted Consult your LNB documentation
17. ions At any time you can press and hold the UP button to switch the meter off When Exit is highlighted you can also use the RIGHT button to switch the meter off The DiSEqC LNB function allows you to send a DiSEqC switch command The DiSEqC menus are explained in detail on page 11 DiSEqC 4 Position switches Option A and B Dual Horn and SMATV Switch commands are supported Custom carrier mode is a new feature which enables you to specify your own carrier to lock on to This can be very useful for optimising a specific service once the satellite has been located and this feature can be used for VSAT installation too You can also store this selection separately from your predefined selections Select your local oscillator first by using the UP and DOWN keys Various local oscillators are available and some have 22KHz tone available also The Local Oscillators are shown in the table below Ka Band 22KHz tone on Ka Band Ka Band Ka Band Ka Band 22KHz tone on C Band C Band 22KHz tone on C Band 22KHz tone on 22KHz tone on Continued Page 8 HDSM USB Sub Menu Using the Custom Carrier feature Continued Now that the local oscillator has been set you can proceed to select your desired frequency Note The local oscillator selected will dictate the available frequency range Carrier 1 0700MHz Sitti 0BH Searching LUE Symb P7500kBd s TETTETETT OGL adlilililili lili Searching E FEC 3 4 S
18. ntact us directly at Horizon Global Electronics Ltd by calling us on 44 0 1279 417 005 or via our website www horizonhge com Page 2 Accessories Your HDSM USB USB PLUS is supplied with this Instruction Manual and these items below Please check if you have all the following If any items are missing please contact your supplier Only manufacturer s replacement parts should be used otherwise safety of the meter may be impaired DC Car Charger Lead Fitted with 2 Amp Fuse USB Lead A AC Mains Charger Lead A Battery Pack MiiH SC 3300mAh 7 24 amp amp Rain Cover should be fitted at all times Leather Case The mains lead should match your region If your mains charger lead is not correct for your region one can be obtained from Horizon or a local supplier importer Note The items shown above are subject to change without notice Please dispose of the packaging carefully and recycle where possible Page 3 Your Meter Front View Loop through connector L band output only DC blocked ar HORIZON sv USB DIGITAL SATELLITE METER P RF Coax Connection from 128 x 64 dot matrix LCD LNB with backlight Back View HORIZON HDSM WARNING Serial number 25126600nn SHOCK HAZARD DO NOT OPEN TO PREVENT SHOCK D NOT REMOVE COVER NO SERVICEABLE PARTS INSIDE DS HOT N TO RAIN OR MOISTURE Ac SUPPLY 100 240 AN replacing COs OSTA MAX battery please refer
19. patible Storage If you wish to store your unit for extended periods of time greater than 3 weeks disconnect the battery connectors When required reconnect and charge overnight prior to use Tip To keep your battery in good working order we recommend a full overnight charge at least once every two weeks for light usage For every day usage we recommend to put your unit on overnight charge prior to the next working day to ensure maximum battery power is available Page 17 Specifications Charging Universal Mains Battery Charger 100V 240V 0 31A MAX 50 60Hz Intelligent charger CE approved with delta V delta T detection Fast Charge then Trickle DC 12V Charger 0 8 Amps 1 3 Amps peak Figure 8 mains input connector 2 1mm female plug for external charge via 12 Volt DC 2 Amp fused car charger Run time with full charge average 5 hours from 3 3Ah NiMH battery Connections LNB input via F type female connector Impedance 75 ohms with short circuit protection 0 5 Amps automatic limiter Computer Interface USB port for updating satellite settings Operating Specifications RF input range 950 2150MHz 65dBm to 25 dBm LNB Supply Voltage 13V for V and 18V for H 250 mA nominal LNB Short circuit protection 500mA 64 Transponders or 32 Satellites horizontal amp vertical DVB C amp KU band QPSK VSAT compatible Input dynamic range 65dBm 25dBm RF Level can be displayed in dBuV general accuracy 1dB or line
20. quency span in MHz In Span view the polarisation of the carrier H orizontal or V ertical is shown If High Band is in use and 22KHz is enabled the tone symbol J L will appear next to the Polarity Centre 10728MHz Span 240MHz The Spectrum information bar at the top of this screen will alternate between the current frequency and span in use Note You can exit spectrum mode at any time by pressing the UP button once This will return you to the searching screen on the selection that you made previously In low signal level conditions use the L Be option to increase the amplitude so that carriers may be seen Tip If you have defined a custom carrier you can view it in spectrum mode too Logging Before using the logging function acquire the satellite that you have chosen ensuring that the received levels are as good as they can be Then access the Sub menu by pressing the UP button once navigate down and highlight the Log as 00000 line By pressing the right arrow at this point the levels from your satellite selection will be stored in to the memory and numbered this number will increment each time your store your measurements Note this number down on your job sheet as you will need to refer to it later wnen downloading the log information from your meter later The logging software required to extract the stored values is available from the Horizon Global Electronics download web page for HDSM products Instructions
21. rn the meter on press the once and the animated Horizon logo will appear The next screen will display the meter information including model version satellite list loaded and battery percentage The third line indicates the file loaded into the meter Use the LEFT or RIGHT arrow keys to cycle through the satellites available until the desired one is shown Point the dish in the approximate direction of the required satellite and slowly sweep the dish across the sky adjusting your elevation at the end of each sweep Whilst you are sweeping the sky the rate of beeps will change as you pass each satellite the scale on the meter will also change You may wish to use the auto ranging function whilst unlocked to re centre the displayed signal level Do this for example if the bar goes blank but there is still a good signal level To use the auto range function press the ON button once twice in Locked mode Once you have located your satellite the HDSM will change tone and Found will be displayed on the screen Peak up on your selected satellite by making fine azimuth elevation and polarisation adjustments to get the S and Q values as high as possible Securely tighten the fixing bolts whilst keeping an eye on the dispay to ensure the best performance from your antenna HDSM USB PLUS C 2007 V1 0B UK 706012 Battery 99 H Astra2A Hi 28E ST 1658p Searching ELITE H Astra2A Hi 28E Se 65Bp a i 100 QBER 8 34E 6
22. rt selected Check to make sure USB Com Port is selected 2 Battery low USB Port Error 1 Drivers not found drivers available from website 2 Check that the USB Lead is connected correctly 3 USB Lead may become damaged or a poor connection may cause communication errors 4 USB Port Damaged I2C Error Indication An I2C error indicates that the internal electronics are not receiving correct communication with the internal tuner Generally caused by 1 Low battery power if the meter has been left In a cold environment this will reduce the battery life 2 Connecting the LNB hot i e while the meter is switched on can cause a surge which will result in an I2C error You should always connect the LNB with the meter switched off Meter Shutting Down 1 Low Battery Charge 2 Sleep timer check timer setting in the Setup menu 3 LNB short circuit or drawing excessive current Meter does not show a lock Make sure you have a current download of files in your meter if it s been a while since you have downloaded you should do so again Also try toggling between BER Linear amp BER Log with meter off hold UP button down until setup display appears scroll down to the bottom amp you will see BER on left side press the RIGHT arrow amp the right side will change between linear amp log Also confirm in the setup display that you have the meter set to display FOUND Apple Mac The software is not MAC com
23. talian German Dutch Polish and Scandinavian Note MER measurements can also be made by changing C N to MER in the setup menu Results will be logged as C N Carrier to Noise ratio or MER modulation error ratio according to this setting HDSM USB PLUS only LNB Voltage This feature enables you to switch the LNB supply voltage off Whist the LNB Voltage is set to 0 Volts the Satellite name on the top line of the display will alternate with LNB OV to indicate that no LNB voltage is applied This selection will remain active until it has been changed back to LNB 13V 18V even if the meter is switched off H Astra2A Hi 28E LNB OV se 01 05 1 65 BU Searching Searching E E Note While the LNB Voltage has been selected as OV then the top line of the display will alternate as illustrated above Page 7 HDSM USB Sub Menu Your HDSM USB has new extras available from the sub menu These features and more are also available on the HDSM USB PLUS Exit DiSEqC Custom Carrier Recall Custom LNB Cable test Exit gt DiSEqC Custom Carrier Recall Custom LNB Cable test Exit DiSEqC Recall Custom LNB Cable test Using the Custom Carrier feature LNB 9 75 VA Seed OBU Searching Ce Once you have made your selection press the right arrow key to set your frequency To access the sub menu press the UP button once from the searching screen Using the keypad as cursor keys you can select the various opt
24. uit the needs of your installation Press the right arrow button to access the the different options available Once a DiSEqC command has been selected with the right arrow key the command will be sent and you will be returned to the last satellite selected The 4 Position Switch option gives you the selections of A B C and D and these selections can be used with a conventional 4 way DiSEqC switch Selecting Exit here will take you back to the sub menu The Options selection enables you to send Tone Burst commands A or B Selecting Exit here will take you back to the sub menu Exit st The Dual Horn option is for use with dual feed LNB assemblies SAT A_Ver_Low enabling you to select the band SAT A_Ver_High and polarisation available SAT A Hor Low individually Selecting Exit here a will take you back to the sub menu The following selections are available from the Dual Horn menu For SMATV switch systems the following DiSEqC command options are available Exit 4 Pos Switch Options Dual Horn gt SMATV Switch Page 11 SMATV switch 1 The SMATV switch option is for use with systems with up to 16 SMATV switch 2 inputs Selecting Exit here will SMATV switch 3 take you back to the sub menu HDSM USB PLUS Menu Note The following additional features are only available on the Sub Menu for HDSM USB PLUS Spectrum mode Spectrum mode is available from the Sub menu press the UP arrow while the signal l
25. zard Completing the Found New j 5 i Tr er The first stage of the driver installation is now The wizard has finished installing the software for complete your computer will NOW proceed to VSP Seil Convene download the additional driver required Click the Finish Button Click Finish to close the wizard Page 14 USB Driver Installation Continued Found New Hardware Wizard 5 Welcome to the Found New Hardware Wizard This wizard helps you install software for To complete the installation of the new additional USB Serial Port driver for the USB Serial Port click the Next Button If your hardware came with an installation CD 29 or floppy disk insert it now What do you want the wizard to do C Install from a list or specific location Advanced Click Next to continue 6 While your PC is searching for the drivers a CREER window like this will appear Please wait while the wizard searches I oy USB Serial Port 7 Found New Hardware Wizard Completing the Found New The Horizon USB driver installation is now Hardware Wizard complete You can now visit the The wizard has finished installing the software for www horizonhge com website for downloads F USB Serial Port Click the Finish Button Click Finish to close the wizard Page 15 Transferring Data Now that your USB drivers are installed you can download selections from the Horizon