1. GLAM LASER PROFESSIONAL LASER USER MANUAL Thank you for using our products For the sake of safety and better operation of this product please read this manual carefully before using and operating it 1 GENERAL INSTRUCTIONS a UNPACKING Thank you for purchasing this product Please read the user guide for safety and operations information before using the product They contain important information about the security of the facility and on the use and maintenance of equipment Keep this manual for future reference In case of sale of equipment to another user it is important that this manual is attached to the equipment to the new user has the necessary information to use and can read the warnings on safety It is essential that the user duly follows the safety instructions and warnings mentioned in that user manual The dealer won t be able be responsible for the defaults or any other problems due to the mishandling from the user and the non following of the instructions included in that user manual This product is suitable for creating perfect laser programs and high quality laser effects This unit is designed to produce decorative effect lighting and is used in light show systems This product is a so called show laser emitting radiation with a wavelength spectrum and producing lasers for shows Please refer to the safety instructions specific for lasers Before any first use unpack the set and make sure there was no damage
2. of 4 meters radius from the public and visibly marked on the ground Only laser beams of wavelengths divergence concentrated their power at a large distance are authorized OPERATION OF THE UNIT The use of lasers is out of the reach of people when considering That the unit is situated at 3 meters above the floor at least That a safety area is defined within 5 meters radius The user takes the responsibility that the units under 3B class or 4 class are mounted by a qualified technician and experienced to the risks of lasers This technician must stay around during all the time the lasers work and he must be able to stop the units in case some technical problems would occur While the installation is on the technician should wear protective glasses Please remind the following remarks Laser light is different from any other light source with which you may be familiar The light from this product can potentially cause eye injury if not set up and used properly Laser light is thousands of times more concentrated than light from any other kind of light source This concentration can cause instant eye injuries by burning the retina Even if you can not feel heat from a laser beam it can still injure or blind you or the audience Never look at the laser aperture or laser beams Do not direct the laser beam to people Do not leave the device running without the presence of qualified professionals EXPELEC can not liable for dam
3. pt tfolx x xx x x o JAUTO ANIMATION ojojijxixixixixixj o stavemone SET DMX ADDRESS DMX MODE DMX ADDRESS CALCULATION In DMX mode the DIP switch from 1 to 9 should be set to record a DMX address The address ranges from 1 511 Each dipswitch represents a binarv value Please refer to table below DMX on 1 Each unit has 12 channels So each product may be receiving a 12 channel DMX address at least If you assign an address on 16 channels the DMX address is 16 N 1 N 0 1 2 3 One loop address 1 two loop address 17 three loop address 33 four loop address 49 Loop Address Binary Dipswitches 1 1 100000000 1 1 switch is ON the others are OFF 2 17 100010000 1 5 1 and 5 switches are ON 3 33 100001000 1 6 1 and 6 switches are ON 4 49 100011000 H 1 5 6 1 5 6 switches are ON The dipswitches setting for DMX address see the DMX Address Quick Reference Chart 5 OPERATION a STAND ALONE OPERATION Sound activation and AUTO This mode allows a single device to react to the sound of music 1 Place the device in a suitable and stable position 2 Set the dipswitch to select AUTO or Sound active mode 3 Turn onthe unit The unit resets then it begins to work 4 The unit will react to low frequencies through the internal microphone Adjust the sound sensitivity with the appropriate knob located at the rear of the unit The LED indicates whether the music mode is activated uote Wa AS A
4. units do not let the inexperienced people come around and operate the device Make sure that the area below the installation is free from unwanted persons The installation should be carried out qualified persons only according to the regulations for safety rules Do not remove the stickers placed on the unit It is forbidden to make any unauthorized modifications to the unit due to safety reasons If some parts are visibly damaged power cord lens plug casing brackets please do not use the unit and contact your dealer The unit does not have user serviceable parts inside Refer to qualified persons or contact your dealer Always use parts of same type Never repair a fuse or bypass the fuse holder Please use the original packaging for transporting the device In the event of serious problems stop using the device contact your dealer Do not open the cover Never look at the light source directly Do not use the unit effects in the presence of persons suffering from epilepsy c SAFETY INTRUCTIONS FOR LASERS According to EN IEC 60825 1 regulations this laser is classified under 3B class Direct eye exposure can be dangerous DANGER LASER RADIATION UNIT UNDER 3 B CLASS AVOID DIRECT EYE EXPOSURE LASER RADAITION CAN CAUSE EYE DAMAGE AND OR SKIN DAMAGE AVOID EXPOSTION TO LASER RADIATION ALL PROTECTIVE MEASURES MUST BE APPLIED FOR MAKING THE USE OF LASERS SAFE This product is a so called show laser emitting radiation with a wavelength s
5. 0 472 504 409 441 473 505 410 442 474 506 411 443 475 507 412 444 476 508 413 445 477 509 414 446 478 510 415 447 479 511
6. ages caused by incorrect installations and unskilled operation 2 SPECIFICATIONS Voltage 230V 50Hz Fuse 2A 250V Rated Power 50W Scanner High speed optical scanner big angle scanning Laser Green 532 nm 100 mW Red 650 nm 200 mW Purple 405 nm 200 mw Working modes DMX 512 12 CH Sound activation Auto beam Auto animation Master Slave PC control Graphics amp Effects 256 128 beam show and animated graphics show patterns Interface 3 pin XLR jack for DMX or Master Slave linking Dimensions 263x 305x 155 mm Weight 4 08 kg 3 FEATURES Animation laser with high optical scanner to create animated graphics 256 128 beam show and graphics show patterns and with the function of unique blanking frequently flashing rotating moving split Zoom speed and color Including 6 working modes as DMX 512 sound active auto animation auto beam master slave for different applications The unit has 14 channels to control in DMX mode The unit has blackout function The unit will shut off if no DMX signal Design according to performance and security Master Slave mode DMX 512 mode and PC control mode will shut off laser automatically without trigger signal gt FRONT PANEL O Gy 1 Laser aperture N y wm O 3 2 Sound active microphone o Jo im O46 j 3 Sound active Indicated Blue LED Sa i GLAM LASER 4 Powerindicator Red LED hel gt REAR PANEL 3 7 5 2 Power Jack Cooling Fan Audio sensi
7. during transport Check for missing any part supplied with the laser 1x GLAM LASER 1x POWER CABLE 1x USER MANUAL b GENERAL SAFETY INSTRUCTIONS This fixture must be earthed to in order to comply with the safety regulations and to avoid any electrical shock Before using please be assure that the voltage is appropriate with the information mentioned at the rear panel of the unit Ot avoid any shock hazard do not open or remove the cover This unit is designed for indoors use Do not expose the unit to rain or moisture The working temperature of the unit is from 18 to 30 C Do not use it at higher temperature Do not switch on and off many times to avoid reducing the life duration of the fixture Do not use the unit for more than 4 hours in order not to decrease the life duration of your fixture Always unplug the unit when we do not use it for a long time or before servicing Do not place metal objects or spill liquids in over the unit If it occurs please disconnect the unit from the mains at once Keep the device away from flammable or hot sources The fixture should be placed in a ventilated area and fixed at 50 cm at least from the walls Do not cover the ventilation openings as it may result in overheating Do not use the unit id dusty environment Please use soft cloth to remove dust that would be place in the external lens Clean the unit regularly Keep away from children or any non qualified persons During the installation of the
8. o KO et m Oe Oe x Os amm Ce miz ag Tnm tt a er ag ma C6 es 1 Master Sound AUTO 2 Master Sound AUTO M Master Sound AUTO b MASTER SLAVE MODE This mode allows vou to connect up to manv together without controller 1 Install the unit in a suitable and stable position 2 Choose a unit to function as master mode set dipswitch to select AUTO or Sound active mode The others must be set in slave mode Set the DIP switch to slave mode 3 Use an XLR cable to connect devices together Taken at the rear of the unit 4 Turn on all units The devices reset and then begin to work The slave units will react the same as the master unit 5 The units respond to low frequencies through the internal microphone Adjust the sound sensitivity with the appropriate knob located at the rear of the unit The LED indicates whether the music mode is activated 1 Master Sound AUTO 2 Slave M Slave c UNIVERSAL DMX MODE This mode allows you to use the DMX 512 console to operate your devices 1 Install the unit in a suitable and stable position Use an XLR cable to connect devices together Taken at the rear of the unit Assign a DMX address for each device using the DIP switch Please refer to the chart on the last page Turn on all devices The units reset then begin to start working Ao o IS Use a DMX console to control your devices iam Cf Bi DMX Signal 1 DMX MODE 2 DMX MODE N DMX MODE NOTE 1 DMX console can n
9. ot be operated in Master Slave AUTO SOUND ACTIVE mode 2 There must be only 1 single master unit in Master Slave mode 6 TROUBLESHOOTING 1 If the power indicator does not lit up and the device does not work please check the power cable is properly connected and if the input voltage is compatible with that of the device 2 In Stand alone operation if the power indicator lights up and sound active indicator does not lit up and the light beam does not work a The sound is too low Increase the volume of music or sound sensitivity b Check if the device is in slave mode then set up in master mode 3 In Master Slave mode the slave units does not work a Make sure there is only 1 single unit in the master channel and the other units are set as a slave b Make sure you are not using a DMX console C Make sure the cables are of good quality and the connections are properly made 4 In DMX mode the beam does not work and the DMX signal is off a Make sure the DMX mode is activated b Make sure the cables are of good quality and the connections are properly made 5 In DMX mode the laser is not controlled by the DMX console DMX signal indicator flashes Make sure the console and the units have the same channel 6 Ifthe direction of the beam is not correct restart the machine 7 Ifthe unit does not work properly turn the unit off then back on If the unit meets other operational problems we recommend that you contact you
10. pectrum and producing lasers for shows A laser Light Amplification by Stimulated Emission of Radiation is a device that emits light trough a process of optical amplification and produce electromagnetic radiation of different wavelengths due to the controlled stimulated emissions process In addition to the secondary effects due to the operating laser conditions fire risks or burning hazards the most important danger comes from the light source The damages on eyes depend on the laser wavelengths specifications the eye distance and the elements linked to the eye specifications This danger is amplifies if the laser beams are focused to tiny spots that is why the effects on eyes are even more important while using lasers 3B class can be dangerous under specific conditions 4 class should be ruled under strict safety warnings INSTALLATION OF THE UNIT The units from 3B class and 4 class exclusively used in open air should be installed by experienced and qualified professionals trained to the specific risks of lasers and should handle a user manual The area reserved for the public should be limited up to 3 meters above the ground and to 2 5 meters from the public This zone should be indicated and marked on the ground In this area it is not possible to make pencil beams through the output being a narrow beam which is diffraction limited in the direction of people whatever the laser class is except if a determined area has been defined
11. r dealer TABLE SET DMX ADDRESS __ 32 64 96 128 160 192 224 286 288 320 352 384 416 448 480 1 33 65 97 129 161 193 225 257 289 321 353 385 417 449 481 2 34 66 98 130 162 194 226 258 290 322 354 386 418 450 482 3_ 35 67 99_ 131 163 195 227 259 291 323 355 387 419 451 483 4 36 68 100 132 164 196 228 260 292 324 356 388 420 452 484 5_ 37 69 101 133 165 197 229 261 293 325 357 389 421 453 465 6_ 38 70 102 134 166 198 230 262 294 326 358 390 422 454 486 7_ 39 71 103 135 167 199 231 263 295 327 359 391 423 455 487 8_ 40 72 106 136 168 200 232 264 296 328 360 392 9 41 73 105 137 169 201 233 265 297 329 361_ RE ga gja 8 5 als ja zje 88 afs HE 8 HE 23 5 87 119 151 183 215 247 279 311 343 375 2o 61 sa 2s rer wo arr om aes 317 3 31 63 95 127 159 191 223 255 267 319 447 424 456 488 393 425 457 469 394 426 458 490 395 427 459 491 396 428 460 492 397 429 461 493 398 430 462 494 399 431 463 495 400 432 464 496 401 433 465 497 402 434 466 498 403 435 467 499 404 436 468 500 405 437 469 501 406 438 470 502 407 439 471 503 408 44
12. tivity knob DMX or linking jack Built in program or ILDA mode conversion 1 See 2 e l 4 Pattern size knob IN rO A RoHS C ila Made in Ctina switch 7 Function of built in program setting dipswitch 4 FUNCTIONS AND SETTINGS a FUNCTIONS i MUSIC MODE The change in the shape of the laser is controlled by the music So the rhythm of the music controls the effect of changing program of the laser ii AUTO MODE Auto cycles the built in programs without being controlled by external sources It has no laser OFF iii DMX CONTROL The system only accepts the DMX 512 signal to control the system mode the laser pattern ON OFF the size the position and the speed DMX Control Parameters Chart Dimmer O 255 AL 600RGY closed red green yellow fixed color random single color random Pattern Select IM Moving X CH12 Drawing FUNCTION SETTINGS First setting Built in program or ILDA mode switch to Built in program or ILDA mode Second If it is setting to ILDA mode then use PC Rolling X Rolling Y Rotation CH1 CH2 CH3 CH4 CH5 CH6 CH7 CH8 H9 software to control laser light If the first step setting to Built in program mode setting built in program dipswitches to mode that include SOUND ACTIVE AUTO SLAVE mode see the Built In Program Function Chart O OFF 1 ON X OFF or ON DIPSWITCH CHART FUNCTION ofo fe x x x x x o sounn acne ateo p e xp x x x 0 arose