Home

7010BSLA sell sheet- 2pg

image

Contents

1. 300290054008429 2 Mounting Slots 3 Locking Pins 4 Hot Black AC Wire Pallet Information 5 Neutral White AC Wire Cases per layer 21 6 Interconnect Orange Wire Number of Layers 7 7 Pull out Battery Drawer 8 Quick Connect Plug Cases per Pallet 147 i Cube 45 29 ft3 Weight 516 29 Ib 2012 BRK First Alert Dicon Global Inc 88B East Beaver Creek Unit 6 Richmond Hill Ontario L4B 4W2 Customer Service 1 800 387 4219 All rights reserved First Alert is a registered trademark of the First Alert Trust BRK is a registered trademark of BRK Brands Inc THE PROFESSIONAL STANDARD brkelectronics com
2. K Model SC7010BSLA and shall provide at a Remote Alarm Ae alarm steady flashing strobe and Red LED minimum the following features and functions Latching Alarm Audio off and corresponding Red lights flashing 2 seconds on 2 1 A177 candela Xenon strobe Indicator seconds off after local alarm unless reset by test silence button 2 The strobe light shall be powered by 120V AC Low Battery Latch Green Power LED flashes green on for 2 3 The Smart Strobe shall have separate flash patterns to distinguish seconds off for 2 seconds between smoke heat and carbon monoxide dangers Sova ULCS531 4 A visual LED green power on indicator to confirm the unit is receiving SHIPPING SPECS O AC power 5 The unit shall be capable of operating between 40 F and 100 F 4 38 C and relative humidity of 10 and 90 i i n Individual Carton 6 The unit shall mount to any standard electrical box up to 4 octagonal Sp 5 25 Hx4 375 W x 5 25 D without screw removal and shall be listed for ceiling or wall mounting Dimensions 0 97 Ib 7 The unit shall have a plug in connector and be capable of Weight interconnection up to 18 multiple station alarms per NFPA 72 Cube 0 07 ft3 8 The unit shall at a minimum meet the requirements of UL1971 ADA UPC 029054008428 ANSI 117 1 CSFM NFPA 72 NFPA 101 and the ICC Master Carton THE PARTS OF THIS SMOKE ALARM oerpake 13 68 L x 5 68 W x 6 12 H Weight 3 07 Ib Cube 0 2759 ft3 1 Mounting bracket 120f5
3. Smoke Alarm with Strobe Light for the hearing impaired PHOTOELECTRIC TECHNOLOGY THE PROFESSIONAL STANDARD CAT 70 1 O BS LA 120V AC DC 60 Hz Wire in with 3V two 1 5V AAA Battery Backup BRK Model 7010BSLA is an ADA hearing impaired strobe light specifically designed for residential and institutional applications including sleeping rooms of hospitals hotels motels dormitories and other multifamily dwellings as defined in standard Smoke aa Batter Meets ADA Alarm Unit Back ip Requirements NFPA 101 BRK Model 7010BSLA is a state of the art Strobe Light designed to provide hearing impaired individuals with a visual warning of a fire or a carbon monoxide danger when used with smoke heat or carbon monoxide alarms The Smart Strobe has separate flash patterns to distinguish between smoke heat and carbon monoxide dangers These different patterns are to help a hearing impaired person better distinguish Smart Strobe the danger present Works with BRK smoke heat and CO alarms Separate flash patterns to distinguish between smoke heat or CO danger Integrated Photoelectric Smoke Alarm and Strobe Light One device includes both a photoelectric smoke alarm and a strobe light Requires only one electrical box Saves installation time The 7010BSLA operates on 120V AC and features a green LED that signals the unit is receiving power Interconnectable with up to 18 devices of which 12 can be 177 Candela Xenon Light smoke al
4. arms Model 7010BSLA was designed with quick and easy installation in mind Designed to cover most drywall cut outs the specially designed mounting bracket mounts on any electrical box up to 4 octagonal and does not require screw removal Connection to AC power is made with a Quick Connect wiring harness Powerful 177 candela xenon strobe light provides effective visual warning to awaken hearing impaired residents 1Hz Flash Rate 60 flashes per minute meets ADA ANSI 117 1 NFPA 72 and UL 1971 requirements for visual signaling devices Battery Backup Two AAA batteries provide backup for the smoke alarm during power outages Note will not power the strobe light Meets ADA Requirements Meets the requirements of the Americans with Disabilities Act ADA Two Latching Features Alarm Latch Visually identifies initiating alarm even after alarm condition is over Low Battery Latch Visually identifies which unit is in low battery condition Two Silence Features Temporarily silence low battery chirp for up to eight hours before replacing battery or silence an unwanted alarm for several minutes NOTE Photoelectric technology is generally more sensitive at detecting large particles which tend to be produced in greater amounts by smoldering fires NOTE lonization technology is generally more sensitive at detecting small fast moving particles which are produced by fast flaming fires Mast
5. er Carton Individual Carton Dimensions Master Cases per Numbers of Cases per UPC H w D Weight Cube I20f5 Pack Layer Pallet BRK First Alert 88B East Beaver Creek Unit 6 Richmond Hill Ontario Canada L4B 4W2 ot 2012 BRK Brands Inc All rights reserved 1 800 482 3720 www firstalert ca ai JOTOBSLA TECHNICAL SPECS Alarm Dimensions 5 0 dia x 4 0 H Weight 10 9 oz Operating Voltage 120V AC 60Hz two AAA battery backup Operating Current 04 1 0 amp standby alarm Smoke Hardwired Battery Meets ADA Temperature Range 40 F 4 C to 100 F 38 C Alarm Unit Back up Requirements RA f Humidity Range 10 to 95 relative humidity RH Audio Alarm 85dB at 10 feet Visual Alarm 177 candela Xenon strobe Flash Rate 1 Hz Smoke Alarm Constant approximately 1 flash per second TOP VIEW SIDE VIEW prota CO Alarm If Alarm is interconnected to BRK CO alarm or combo Co alarm the intermittent approximatley 1 flashper second for four seconds Alarm Reset Automatic when smoke and or CO clears 7 Press test silence button to silence manually S Interconnections Up to 18 units of First Alert or BRK Smoke CO cs andHeat Alarms Maximum of 12 smoke alarms lil See user s manual for details Smoke Sensor Photoelectric Indicator Lights Sounds AC Power Constant Green LED Local Alarm Audio alarm steadily flashing strobe and rapidly flashing Red LED The strobe light shall be a BR