Installation of the Opener

image

Contents

1. Auto close time of the gate opener is 30 60 90 seconds DIP Switch 8 Left Right open r OFF Right open For gate to open toward right and close toward left ON Left open factory default setting For gate to open toward left and close toward right eee 2 Potentiometers Potentiometer A and B are used to adjust the stall force of the gate opener Both two potentiometers of factory default force have been set to at 15 00 o clock Turn the potentiometer clockwise to increase the stall force Turn the potentiometer counter clockwise to decrease the stall force 13 Potentiometer A Potentiometer B Control Board MAX MIN Test the reversing sensitivity For the sake of safety it is very important to test the reversing sensitivity as soon as the control board set is finished The reversing sensitivity adjustment is inverse correlation with stall force adjustment in potentiometer A and B In other word the stall force level is higher the reversing sensitivity level is lower Put an immobile object along the gate path and then operate the gate to strike it during the open and close cycles The gate must reverse as soon as object is struck with it If the gate doesn t reverse please increase the reversing sensitivity by turning the potentiometer in counter clockwise direction Turning the stall force potentiometer toward to MIN position to increase the reversing sensitivity Note
2. 1 If the sensitivity setting is too higher the gate will stop or reverses very easy by itself while there is little obstruction or resistance such as strong wind or heavy snow sometimes Note 2 Always check the gate reversing function every each time of control board set or restart after power off How to learn or erase the remote REM LED PWRLED Learn the remote Press and release the learn button the REM LED light will be on then press the key in the remote twice Learn Button in 2 seconds the REM LED light will flash for 4 eo seconds Now the remote has been learnt successfully Erase all the remote codes Press and hold the learn button until the REM LED light is off Now all remote codes have been erased How to use the remote to control the opener KeyA REMOTE Key 8 Key A is used to operate the opener to work alternately open stop close stop open When the Pedestrian Mode function is enabled Key B is used to achieve the Pedestrian Mode function open the gate for the pre setting time When the Pedestrian Mode function is disabled the opener works alternately open stop close stop open by pressing Key B Troubleshooting Have a multimeter to check voltage and continuity Use caution when checking high voltage terminals Symptom Possible Solution s The opener does not run Power LED is OFF 1 Make sure that the power cord is properly plugged into the mains outlet 2 Check if the output vo
3. The RED wire of the alarm lamp should be connected into the 7 terminal 4 Photocell Use a 2 core cable to connect the terminal of the photocell s emitter to the 16 terminal the terminal to the 17 terminal Also the and terminals of the photocell s receiver should be connected to the 16 and 17 terminals in parallel Use another 2 core cable to connect the OUT terminal of the receiver to the 8 terminal the COM terminal to the 9 terminal 5 Push Button The push button should be wired to the 10 and 11 terminals The gate opener works alternately by pushing the button open stop close stop open 6 Loop Detector First insert the LOOP DETECTOR BOARD into the CONTROL BOARD and then connect the twisted pair to the 14 and 15 terminals 7 External Receiver The BROWN wire of the external receiver should be connected into the 11 terminal The BLACK wire of the external receiver should be connected into the 16 terminal The RED wire of the external receiver should be connected into the 17 terminal 8 Wired Keypad 24VDC The RED wire of the wired keypad should be connected into the 17 terminal The BLACK wire of the wired keypad should be connected into the 16 terminal The BLUE wire of the wired keypad should be connected into the 10 terminal The WHITE wire of the wired keypad should be
4. connected into the 11 terminal 9 Battery The negative terminal of the battery should be wired to the 18 terminal The positive terminal of the battery should be wired to the 19 terminal 10 Solar panel Please refer to the manual instruction of solar panel and controller separated w Be Ge Go Ge G Ge Ge Ge Ge G Ge G Ge Ge Ge Ge Ge Ge G Hee Ee S TIPS a N The terminal 8 and 9 on control board should be shorted if the Si b photocell beam system optional does not use A wire jumper has eeo 6 been used for short to terminal 8 and 9 in factory Please check if this wire jumper is missing or keep the photocell in alignment when the gate amp can open but fails to close A D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D D Setting Of The Control Board WARNING Keep away from the gate during you set the gate opener system in case of the unexpected gate moving Carefully adjust the DIP switches to avoid the risk of machine damage and injury or death Always ask the help of professional technician electrician if you have any question Control Board DIP Switches uwe iias E PHOTOCEL PUSHBUTTON 9 9 9 R 1 DIP Switches The DIP switches are used to set the running time of the motor in pedestrian mode fine adjust the soft stop period of the motor auto close time of the gate opener and fast change the ope
5. e ee eeee ee ee ea eaeeeeeeeaeaeaeeeeeseunaees 9 Connecting of Power Supply cccccccec eee ee eee eect eee aiaa AA ae Aa i EAEE s 10 Connecting of the Control Board ccc cece cece cece ee eee eee eee e eects eee eee eee e eee ee rerna neeea eee eee 11 Setting of the Control Board cccce cece eee ee eect eee eee ects eee eee eee esses ease eeneesneaeaeaseeeeeeees 12 Test the reversing sensitivity 0 cece cece cere eee eee e ene eee eee eee c eee ence eae na ea eas aaesaaeaaaeenneees 14 How to learn or erase the remote cece cece cece eee eee eee eee cee ne ene nena deen e eee eee aetae 14 How to use the remote to control the Opener cccece cece cece cece ee eee eee eee eee ee tees tees eaeeeeaeaes 14 Trouble Shootings re n a a e a ade D a dein stag E die NEE agit ato 15 Maintenance seanar ataa ninnan aden A Gee ga OA AED ON EA a eee Bade dd dame pay a a Pani knee 16 Thank you for purchasing DSC 600 DSC 1000 sliding gate opener We are sure that the products will be greatly satisfying as soon as you start to use it The product is supplied with a user s manual which encloses installation and safety precautions These should be read carefully before installation and operation as they provide important information about safety installation operation and maintenance This product complies with the recognized technical standards and safety regulations General Safety A WARNI
6. Higher Magnet amp Concrete Pad Gate Operator Chain Lower Magnet amp U Bolt amp Photocell Magnet Bracket Magnet Bracket L Bracket amp Base Plate Chain Bolt Installation of the Opener Caution Be sure that the opener is installed in a level and paralleled position and is properly secured Improper installation could result in property damage severe injury and or death Before starting installation ensure that there is no point of friction during the entire movement of the gate and there is no danger of derailment Ensure that the Warning Signs are present pss A Necessary Tools The following tools may be I i i r i Gate O necessary to install the Gate opener You will H as E need screwdrivers an electric drill wire cutters _ Hex Boit ma 30 4 pos p am E Spring Washer 8 4 pes ez and a wire stripper a socket set and possibly P a n Washer 4 pcs A access to a welder When install the opener you should build a Socket Head Screw jij concrete pad to support the base plate of opener Spring Washer 6 4 pcs Plain Washer 6 4 pcs in order to maintain proper stability x i The installation proceeds are as follows AA k os 1 Dig a hole for a concrete pad which should be s U approximately 60 x 32 x 35cm 24 x 13 x 14 Sping Washer ey It may protrude 10 cm 4 above ground and sy pan Wate 25 cm 10 in depth underground Increase t
7. LockMaster Sliding Gate Opener User s Manual Model DSC 600 1000 Please read and follow all warnings precautions and instructions before installation and use Periodic checks of the opener are required to ensure safe operation For residential use only Save this manual www WholesaleGateOpener com Beenie Table of Contents General Safety esac vind deodoves sienna pave ea dada eed e AE die ited dca e ara s TREE wing dea vated sae Dade 2 Preparation Tor Installations sseivia ce ceases ne date dea eee cgeg se vars aa a pind nye vhe etal A Lee aga SAh 3 Pants List sosteisne sch chorale vag wiesa a a e Md bad etabsesn gud dash aa aaa aa aag Ana Taai EE 4 Optional Accessories Part List c ccccec eee c eee e cee eee eee eee ene eee ee ee ee eae ences ea ease ea eseeeaeaeaeaeeeeeseees 5 Technical Specifications amp Feature cccccccceeee eee eee ee eee eee eee nett nent eens ee eeeeeeeeeeeeeeeeeeeeeeeeeeeeasas 6 Installation Overview neiseina eran teste ea aa od ahead eta book tage ee oe 6 Installation of the Opener nireseta capecdedode shaded eased gga caus Seedag aaa aKa ENEE saaka a 7 Manual Operations ce sccc ascsdeastanceeser gena era eai cebbess petard aaeei ae seeds 7 Installation of chain and chain brackets cccccececeeee cece eee eee eeeeeeee ease essa ease ee eneeeeeeeeeeeeeees 8 Installation of Magnets for Limit Switches 0 ccc cece ec ec cence eee cece eee
8. NG An incorrect installation or improper use of the product can cause damage to persons animals or properties e Scrap packing materials plastic cardboard polystyrene etc according to the provisions set out by current standards Keep nylon or polystyrene bags out of children s reach e This product was exclusively designed and manufactured for the use specified in the present documentation Any other use not specified in this documentation could damage the product and be dangerous e The factory declines all responsibility for any consequences resulting from improper use of the product or use which is different from that expected and specified in the present documentation e Do not install the product in explosive atmosphere e The factory declines all responsibility for any consequences resulting from failure to observe Good Technical Practice when constructing closing structures door gates etc as well as from any deformation which might occur during use e Disconnect the electrical power supply before carrying out any work on the installation Also disconnect any buffer batteries if fitted e Fit an omnipolar or magnetothermal switch on the mains power supply having a contact opening distance equal to or greater than 3 5 mm e Make sure a residual current circuit breaker with a 30mA threshold is fitted before the power supply mains e Check that earthing is carried out correctly connect all metal parts for closure doors gates
9. chain brackets inai 1 i j p figure which shows U bolt L bracket a ee and chain bolt Picabrrne eau pe Use the U bolts square or round to attach Hex Nut M8 4 pes gt the chain brackets to gate frame l ee ia ia ee 2 If Both the square bolts and round bolts Ss os Hex Nut M10 2 pes are not fit for the gate frame use the as or hh appropriate bolts to attach the chain OaE i l brackets to gate frame E J Master Link Chain Bolt L Bracket 2 How to install the chain 1 Place the chain around the top of the idler wheels and under the drive sprocket in chain box 2 Connect a chain bolt to one end of chain from chain box by using master link Then insert the chain bolt to the L bracket and fix them each other by washers and nuts temporarily Nuts will be further adjusted for a proper chain tension later 3 Connect second chain bolt with another end of chain from chain box then attach bolt to the L bracket on opposite end of gate using the washers and nuts 4 Make sure that the chain is line up exactly with the position where the chain on the chain idler wheel 5 Get the desired chain tension by adjusting two chain bolts of the both end Cut the unwanted length of chain if necessary 6 Fix the base plate by tightening the washers and nuts rA 7 Insert the opener shaft into the drive sprocket of chain box Mount the opener by tightening th
10. e bolts and washers 8 Fix the chain box by tightening the four lax screws aAa Chain Bolt AT Orive Spreke pas EN ENN E s Bann idier Wheel Master Link Chain Thoroughly fasten the four nuts as well as spring washers onto anchor bolts tightly enabling the opener is firmly secured on the concrete pad during the whole gate travel 3 Check position of opener and chain brackets 1 The chain brackets must be mounted to the same height as the chain on the idler wheels 2 The opener must be parallel to the gate 3 Make sure there is 1 distance at least between the chain box and the gate after you position the base plate aa Chain Box Wall Wall L c i Gate f E Chain Box coe E Installation of Magnets for Limit Switches Before install limit switch make sure the gate opener is put in manual operation the clutch connected with gear shaft is disengaged and the mains power supply is disconnected Position the two Magnet Components approximately on the gate and move the gate by hand to fix them in place Fit magnets bracket Push the gate fully closed by hand Locate and install the magnet bracket so that the opener will stop at the desired close position when the close limit switch approaches it Push the gate fully open by hand Locate and install the magnet bracket so that the opener will
11. e is in good mechanical condition correctly balanced and opens and closes properly e Save these instructions for future use Preparation for Installation Before proceeding to your opener installation check if your gate structure is in accordance with the current standards especially as follows The gate sliding track is linear and horizontal and the wheels are suitable the gate should be mounted and moving freely Check that the structure is sufficiently strong and rigid and that its dimensions and weights conform to those listed in the specifications table of this document Make sure that the gate is plumb and level The fence posts must be mounted in concrete The gate does not bind or drag on the ground e The gate manual operation can be carried out smoothly along its entire run and there is no excessive side slipping e The opening and closing gate stops are positioned A WARNING Remember that control devices are intended to facilitate gate operation but can not solve problems due to any defects or deficiency resulting from failure to carry out correct installation or maintenance Take the product out of its packing and inspect it for damage Should it be damaged contact your dealer Remember to dispose of its components cardboard polystyrene nylon etc according to the current prescriptions Refer to the following Figures for gate installation Using the post or wall as a stop either directly or indirectly is not recom
12. e lower limit switch if the motor couldn t run in counter clockwise direction 3 Replace the control board Maintenance Every six months check the following items for proper operation of the unit Lubricate shafts and sprockets Keep opener clean at all times Check and tighten anchors bolts Check for loose or corroded wire Ensure the opener is well earthed and correctly terminated Always check the Stop Reverse in case of obstruction function when performing any maintenance If this function can t be made operable remove this opener from service until the cause of the malfunction is identified and corrected According to Waste of Electrical and Electronic Equipment WEEE directive WEEE should be separately collected and treated If at any time in future you need to dispose of this product please do NOT dispose of this product with household waste Please send this product to WEEE collecting points as where available www WholesaleGateOpener com 7106 S 220th St Kent WA 98032 USA sales WholesaleGateOpener com 2010 2012 LockMaster All Rights Reserved
13. emote control Replace the battery if necessary 2 The distance you use the remote is too far away from the opener Try it again closer 3 Remote control is not suitable for receiver After making sure the codes are correct erase remote controls and then re program the codes in the device 4 Replace the control board The gate starts but it is immediately stop or reverse 1 Check that the clutch is adjusted properly and is not slipping 2 The opening force or closing force is adjusted too small Turn the Potentiometer A to increase the force 3 Disconnect the gate from the gate opener and check that the gate slides freely without any binding 4 Replace the control board The gate opens but stops and will not return 1 Please note the two magnet brackets fixed plate are different one is higher and another is lower Please try to exchange the two brackets position 2 Please try to exchange the limit switch wires CL close and OP open 15 3 Maybe the magnet position was installed in the middle so it inducts both switches Adjust the magnet higher or lower The gate can open but fails to close 1 Photocell is obstructed Remove obstruction 2 The limit switch is failed Use a jumper wire to short terminal 4 with terminal 3 and 5 and then use a keying device to operate the opener replace the higher limit switch if the motor couldn t run in clockwise direction and replace th
14. etc and all system components provided with an earth terminal e Fit all the safety devices photocells electric edges etc which are needed to protect the area from any danger caused by squashing conveying and shearing e Position at least one visible indication device Alarm lamp and fix a Warning sign to the structure Moving Gate Can Cause Injury Or Death 1 Keep Clear Gate may move at any time s 2 Do not allow children to operate gate or e The factory declines all responsibility with respect to the automation safety and correct operation when other supplier s components are used e Only use original parts for any maintenance or repair operation e Do not modify the automation components unless explicitly authorized by the factory e Instruct the product user about the control systems provided and the manual opening operation in case of 2 emergency e Do not allow persons or children to remain in the automation operation area e Keep radio control or other control devices out of children s reach in order to avoid unintentional automation activation The user must avoid any attempt to carry out work or repair on the automation system and always request the assistance of qualified personnel e Anything which is not expressly provided for in the present instructions is not allowed e Before installing the gate opener check that all moving part as well as the sliding gat
15. existed short circuit of terminal 4 and 5 2 Solder the two wires to the terminals of the switch respectively Pa Spe NOTE The power supply cord is not included in the package 6 J NOTE Make sure a residual current circuit breaker with a30mA threshold is fitted before the power supply mains NOTE The protection class of the emergency stop switch should be at least IP44 pa Connecting Of The Control Board CONTROL BOARD GAGS CJZIEI GSLiED CALE MOTOR LL COM RL LAMP PHOTOCELL PUSHBUTTON LOCK LOOP 24VDCOUT BAT Reserved reserved reserved Limit Switches Battery LM125 Alarm Lamp LM140 1 RED Emitter Receiver ae OUT TERMINAL IN RECEIVER D nee TERMINAL IN RECI 716 A I Es aaa E l External Receiver LM138 Photocell LM102 TERMINAL IN EMITTER l OOOO Loop Detector LM154 Push Button LM145 Wired Keypad LM106 24 1 Motor The YELLOW wire of the motor should be connected into the 1 terminal The RED wire of the motor should be connected into the 2 terminal 2 Limit Switches The YELLOW wire of the limit switches should be connected into the 3 terminal The BLACK wire of the limit switches should be connected into the 4 terminal The RED wire of the limit switches should be connected into the 5 terminal 3 Alarm Lamp 24VDC The WHITE wire of the alarm lamp should be connected into the 6 terminal 11
16. he pa i 5 R pad height if necessary to protect the system 4 pes La J from flooding heavy snow etc SON N gt 2 Prepare one or more conduits for the electrical Be cables before pour concrete Remember that iL 5 cable conduits have to pass through the hole in Conduit Y the base plate 3 Pour concrete and before it starts to harden check that it is parallel to the gate leaf and NEN sata Bee perfectly level eS 4 The four anchor bolts must be set into the concrete when it is poured make sure the position of anchor bolts was placed according to the position of mounting holes on the base plate before concrete become harden 5 Mount the base plate to the concrete Pad It s only temporary installation Further adjustment will be required when install the chain 6 Mount the chain box to the base plate by using screws and washers don t make the four screws too tight Manual Operation The opener should be put in the manual emergency release position before fitting the chain installing the opener and limit switch The process is as follows 1 Take of the rubber stopple 2 Insert the Release Key provided and turn it in counter clockwise 180 to disengage the clutch between the gear shaft and power output Now the opener is in the manual operation Release Installation of chain and chain brackets Gate Frame 1 Chain Brackets i ZZETITIZZ TDS N A m z 1 Please refer to below
17. lar LM117 LM109 panel 1 pc LM115 Mounting post for keypad 1 pc LM107 Keypad wireless Wired Keypad 1 pc LM106 24 1 pc LM105 ID card LM170 me 250 PCS Max External Receiver 1 pc LM138 7 Video Intercom 1 set LM165 Wall push button 1 pc LM147 Bracket for solar panel 1 pc LM116 Loop Detector 1 pc LM155 Technical Specifications amp Features Specifications Power supply 230V 50HZ or 120V 60HZ Absorbed power 180W for DSC 600 350W for DSC 1000 Gate moving speed 0 2 m sec Max gate weight 600KGS for DSC 600 1000KGS for DSC 1000 Max torque 12Nm for DSC 600 24Nm for DSC 1000 Ambient from 15 C to 40 C Humidity max 75 Protection class IP44 Dimensions 396 x 190 x 555 mm Features Get the desired chain tension by adjusting the chain bolts Soft start and soft stop Midway mode Quick selection for gate open close direction Reliable rolling code technology Emergency release key in case of power failure Stop Reverse in case of obstruction during gate opening closing Built in adjustable auto close 0 30 60 90 seconds Built in max 90 seconds Motor running time MRT for multiple safety protection Reliable electromagnetism limit for easy adjustment Can be equipped with a wide range of accessories Installation Overview Sliding Gate Alarm Lamp __ f
18. ltage of the transformer is 24VAC If the voltage measures 0 the transformer may be overheated or damaged Turn power off and allow board to cool for several minutes then reset Replace the transformer if the symptom still exists 3 Check the fuse in the control board Replace the fuse if it was burnt out 4 Check the control board Replace the control board if necessary The opener does not run Power LED is ON 1 Check to be sure the beam is not blocked if a photocell is used as a secondary entrapment prevention device If a photocell is not used terminal 8 should be shorted with terminal 9 by a jumper wire 2 Check the motor Release the clutch then disconnect the wires of the motor from terminal 1 and 2 Connect the wires to the terminal 16 and 17 directly the motor should run and then exchange the wires the motor should run in the opposite direction If the motor runs in both directions please check the other parts listed below 3 Check the limit switches Use a jumper wire to short terminal 4 with terminal 3 and 5 and then use a keying device to operate the opener replace the higher limit switch if the motor couldn t run in clockwise direction and replace the lower limit switch if the motor couldn t run in counter clockwise direction 4 Replace the control board if the motor runs in all steps above Remote control does not work 1 The indicator light of remote control is not on Check the battery in your r
19. mended so as to protect the post or wall against damaging shock from the sliding gate Closing gt l incorrect J In sake of safety a positive stop must be mounted on the two end of ground track Th Positive Stop in fully closed position Keep the 3 distance at least between operator and chain s B A bracket if the roller hit Positive stop in an accident A B23 pee Parts List Magnet bracket 2 pcs Magnet Assembly 2 pes M8x70 Bolt 4 pcs M8 x30 Bolt 4 pcs It is suggestion that there is a 4 10cm distance at least between the gate edge and the gate wall when the gate is fully open ee Positive Stop in fully opening position Keep the 3 distance at least between operator and chain bracket if the roller hit Positive stop in an accident Remote Control Chain 20ft Master Link 3 pcs O 6 Washer 4 pcs C tA 10 Lock Washer 8 Lock Washer 6 Lock Washer 8 pcs 24 pcs 4 pes oer Socket Head Screw M10 Nut 8 pcs M8 Nut 20 pcs M6x40 4 pcs Optional Accessories Parts List Optional Back up battery 1 set LM125 Battery emergency charger 2 5 Video Intercom 1 pc LM135 1 set LM162 Back up battery box 1 pc Alarm Lamp 1 pc Photocell Beam System LM130 LM140 1 set LM102 Solar Controller 1 pc Solar panel 1 pc Supporting frame for so
20. n close direction which is determined by the position of the gate opener installed 12 DIP Switch 1 2 Running time of the motor in Midway Mode DIP Switch 1 ON 2 Seconds OFF 0 DIP Switch 2 ON 4 Seconds OFF 0 NOTE The midway mode function would be disabled if both DIP switches are turned off Factory default setting is disabled 12 3456 7 8 Running time of the opener in pedestrian mode is 2 4 6 seconds DIP Switch 3 5 Fine adjust the soft stop period of the motor DIP Switch 3 ON 1 Second OFF 0 DIP Switch 4 ON 2 Seconds OFF 0 DIP Switch 5 ON 4 Seconds OFF 0 NOTE Every time you restart the gate opener after power off you should use the access control device such as remote push button and etc to operate the gate opener to run for a complete opening cycle and a complete closing cycle to get the full opening time and the full closing time You would achieve the soft stop in your next opening closing cycle Factory default soft stop time is 0 Second You can turn the DIP switches on off to fine adjust the soft stop time to meet your actual needs 12345678 DIP ON The soft stop period of the motor is 1 2 3 seconds DIP Switch 6 7 Auto close time of the gate opener DIP Switch 6 ON 30 Seconds OFF 0 DIP Switch 7 ON 60 Seconds OFF 0 NOTE The auto close function would be disabled if both DIP switches are turned to off factory default setting
21. stop at the desired open position when the open limit switch approaches it The higher magnet component must be installed at left side and lower magnet component must be installed at right side from the view inside of property Finally adjust the magnet to the proper position by moving the gate with the motor The magnet should be 39 59 away from the magnetic limit switch If it is too far away the switch will fail to work The distance between the magnet and the opener should be 1 2 12mm with the opener cover on Adjust the position of the magnet until the positions of the opening and closing meet the requirement 9 10 15mm Magnet Bracket F Higher Magnet 2 pcs f Component Lower Magnet Component la H A Hex Bolt M8 70 4 pes B Plain Washer 8 E J 4 pcs Spring Wahser 8 4 pcs Hex Nut M8 4 pes ae x n nr Gate Operator Chain Box Connecting Of Power Supply ea The power supply cord should be at least HO5R1V F 3x0 75mmz2 i Connect the live wire neutral wire and earth wire to the L N and PE terminal respectively It is strongly recommended that an emergency stop switch is installed in the electrical system which can be used in case of the remote control failure You can connect the switch by the following steps B 1 Cut off the wire which has been connected between terminal A 4 and 5 in factory to deactivate the