Home

User manual

image

Contents

1. 0 Not used White light 11 Troubleshooting Symptom Cause Solution Is the power ON Turn ON the power Is the supply fuse intact Replace the fuse Is the power cord properly connected Is the lid closed and the lock screw completely tightened interlock will Tighten the screw completely be activated Reinsert the power cord Check with the installation instructions Let it cool off for approx 5 minutes and try again Replace the lamp with a new one No light fan running Let light generator cool off for Was the power away shortly 5 minutes before switching OFF and then ON Is the light generator too hot while Check with the installation operating instructions Is the light generator too hot Is the lamp blown Light switches ON and OFF Is the fan blocked Clear the airways Replace the fan with a new one Replace the lamp with a new one Clean the filters with a damp Are the filters dirty cloth Finish by wiping off with a dry lint free cloth Clean the harness common Is the fiber harness common end end with a damp cloth Finish dirty by wiping off with a dry lint free cloth Is the fan not running Is the lamp old The light output has diminished Note When taking the power away shortly the light generator s ballast will try to reignite the lamp only once This means that if the lamp is too hot the
2. 99082036 rev 5 07 2006 FL 250 B C and F 250 W Metal halide light generator for fibre optic lighting systems User manual This mounting instruction describe installation and service of the following products Item no 01700010 01700050 01700055 01700020 01700030 01700035 01700040 FL 250 B FL 250 F Colour Wheel FL 250 F Twinkle Wheel FL 250 C DMX Dual Wheel FL 250 C DMX Colour Wheel FL 250 C DMX Dimmer Wheel FL 250 C Synchron Roblon 1 Introduction Your ROBLON Fiber Optics metal halide light generator type FL 250 is intended for indoor use in fibre optic lighting systems using either glass or PMMA fibres The metal halide light generator has been developed to meet the requirements of a Roblon fibre optic lighting system where the light output intensity and efficiency is optimised in order to ensure the best performance and safety This manual should serve as a guideline to how the system is operated in the safest way Following the recommendations in this guideline all contribute to e Enhanced functionality e Extended lifetime of components e Uninterrupted system illumination Contents Tas Nnirod cti iienaa aana aaran aeaaea aaae aaa aa aaa cnueenasancatusseassanaiuaenanssuwsiaeaseueaauauesenededses 2 2 Product Overview and Packing Listsvccicsiciiisvesctacosieisseieantasncedeteweresntaeneavieceussevanevesnanwien 3 Su Fechnical Infoeier aei aae esea auwaadebuwasntataniaaisGdenseueaunbuniuaawaunnad 3 4 In
3. 03 0066 DMX and Synchron line Male 9903 0065 Termination Roblon accepts no responsibility for possible errors in printed and electronic material Roblon reserves the right to alter or discontinue products without notice 2012 Roblon A S Roblon Roblon Lighting Nordhavnsvej 1 9900 Frederikshavn Denmark Tel 45 9620 3300 Fax 45 9620 3399 info roblon com www roblon com 12
4. changes between all the colours of the wheel Smooth colour changes between colours green and orange Colour changes at 50 dimming Smooth colour changes between colours blue and red Colour changes at 50 dimming Smooth colour changes between colours green orange blue red yellow and backward Colour changes at 50 dimming Full colour Use code wheel 2 to change colour 1 White 2 Green 3 Orange 4 Blue 5 Red and 6 Yellow Not used Not used Not used 8 Control Cabling of FL 250 C Connections with 5 pin XLR Max signal cable length of the whole installation is 120 meters 1 Connect the first light 2 If there are more than one light Generator to DMX controller generator they must be connected serially See drawing below 2 Inthe last light generator a line termination must be mounted in the DMX out Serial data connection of light generators 9 DMX 512 Control Features for FL 250 C When the light generator s address is defined it is possible to control it using a standard DMX console like the Linebacker or Alcorn McBride The lists below define the available features The numbers refer to the real DMX values of each channel Address is set with three 10 digit code wheels in the lid Each light generator take up 2 addresses and 3 addresses if they contain dimming wheel First channel is specified with the code wheel The second and possible third follow increasingly Address settings Code wh
5. eel 1 Towards the light port x100 Code wheel 2 In the middle x10 Code wheel 3 Towards the back x1 Control 1 channel 5 sec delay on all functions 000 018 Not assigned 019 039 Lamp OFF 040 050 Not assigned 051 070 Shortest mode 071 080 Not assigned 081 100 Linear mode 101 120 Not assigned 121 144 Reset colour and dimming wheels 145 160 Not assigned 161 179 Reset colour wheel 180 220 Not assigned 221 239 Lamp ON 240 255 Not assigned Colour wheel 2 channel 000 200 Position of colour wheel 201 205 Not assigned 206 230 Variable speed of rotation clockwise 1 rev min at 217 231 255 Variable speed of rotation counterclockwise 1 rev min at 242 Frames 1 through 6 at one 033 067 100 133 167 Colour White Green Orange Blue Red Yellow Dimming wheel 3 channel 000 200 Position of dimming wheel 000 is no light 167 is full light 201 205 Not assigned 206 230 Variable speed of rotation clockwise 1 rev min at 217 231 255 Variable speed of rotation counterclockwise 1 rev min at 242 Frames 1 through 6 at rn 033 067 100 133 167 Intensity 0 6 12 25 50 100 10 Controlling the FL 250 C synchron light generators Connect the synchron light generators into the line of light generators via a standard type DMX cable with a 5 pin male XLR plug For instructions see chapter 8 Set all the connected slave light generators to chan
6. ered from ROBLON Do not operate the unit unless top is closed and secured by screws SAVE THESE INSTRUCTIONS 2 Product Overview and Packing List Contents of this box Plastic bag Light generator FL250 series Allen key User manual Power cord 3 Technical Info Light port size O28 Fibre type PMMA Glass Supply voltage 100 240 V nominal 50 60 Hz Lamps 250W BLV type MHR 250 N 4200K Power consumption 288 300 W Fuse 5A Power cord Power cord W ground Data connection 5 pin XLR Ballast Electronic Thermal protection Auto reset Cooling system DC axial fan Fan noise level 38 db A Ambient temperature 30 C to 40 C Lamp type Metal halide Lamp life time 5000 hours Lamp colour temp 4200 K Material Aluminium anodised Dimensions L x W x H 414 x 234 x 160mm Weight 4 5 4 8 kg Safety approvals CE EMC comply FCC comply CB cULus 4 Installation Instructions Unpack the unit and make sure that the grounded power supply cord is suitable for your country The light generator is prepared for universal power input capable of running from 100 240 V nominal 50 or 60 Hz 1 Fully insert the fibre harness 2 Tighten the grille screw with 3 Connect the power cord at common end into the light the supplied Allen key the back of the light source port of the light generator NOTE Before switching on make sure that the requirements in the installation instructions are observed Place the li
7. ght generator Do not place the light generator Always place the light Do not place the light generators Too close to a wall The light generator on the feet on top of each other generator has too get rid of the The heat cannot come from heat from the lamp the light from generator Do not place the front of the light Make sure that hot air from one light generator generator too close to a wall does not blow directly into the air intake of the light generator next to it f Se 300 5 Changing lamp 1 Remove the locking screw at the back 6 Changing fuse 1 Use a screwdriver to loosen the fuse holder 2 Check the fuse 2 Open the lid 4 Loosen the thumb screw in the lamp bracket 8 install the new lamp in reverse order Orient the lamp such that the front wire points upwards close to mark Mark Front wire 3 Change the fuse if necessary and push the fuse holder back in place 7 DMX Stand Alone Mode for FL250 C Six built in programs for colour changing and choosing are available Code Wheel 1 Towards the light port 9 The light source is in stand alone mode Code Wheel 2 In the middle 0 9 Varies the pauses between the changes 0 is the shortest and 9 is the longest Code Wheel 3 Towards the back oOnm o aN oO ON Not used Colour changes between all the colours of the wheel Smooth 5 sec colour
8. lamp will not start immediately It will be nescesary to let the lamp cool off for about 5 minutes then take the power from the light generator and reinsert the power again to ignite the lamp Warning Only a properly trained person should undertake the work of servicing other than the above mentioned 12 Spare parts and accessories Description Model designation Roblon item no Lamp BLV 250W MHR 250N 6525 0003 Fan Papst 4212 NM 6412 0012 Dichroic Yellow colour filter with bracket 7800 0390 Calour titei Dichroic Green colour filter with bracket 7800 0391 Dichroic Blue colour filter with bracket 7800 0392 Dichroic Red colour filter with bracket 7800 0393 CTC filter 500K 7800 0397 CTC filter CTC filter 900K 7800 0399 CTC filter 1200K 7800 0398 Colour wheel Standard colour wheel 5100 0078 Dimmer wheel Standard dimming wheel 5100 0088 Twinkle Wheel Standard Twinkle wheel 5100 0084 Electronic ballast 250W 100 240 VAC 50 60 Hz 6708 0065 Motor for C DMX models Stepper motor 1 8 6400 4000 Gear motor for F models 1 rom 50sec 110 Vac 6400 1215 LineBacker 0160 0300 Broa Comore Alcorn McBride 0160 0301 DMX 512 Splitter Y distributor in a DMX system 0160 0310 Syncron control unit 0160 0325 Length 2 5m 9903 0056 DMX and Synchron Cable Length 5 m 9903 0052 Incl 2 plugs male and female Length 10m 9903 0057 Length 51 100 m Please state required length 9903 0058 Synchron Line Termination Female 99
9. nel 800 and they will be synchronized with your choice of program on the master light generator that should be set according to the following Set one light generator as Master by setting code wheel 1 to 9 Programs are set with the code wheel 3 1 Fast 0 2 sec colour changes between all the colours of the wheel 2 Smooth 5 sec colour changes between all the colours of the wheel Pauses in programs 1 and 2 Code wheel 2 0 1 2 3 4 5 6 7 Pause in sec 0 8 1 7 2 5 3 3 4 2 5 5 8 6 7 7 5 8 3 3 Smooth colour changes between colours green and orange 4 Smooth colour changes between colours blue and red 5 Smooth colour changes between colours green orange blue red yellow and backward Pauses in programs 3 4 and 5 Code wheel 2 0 1 2 3 4 5 6 7 8 9 Pause in sec 7 5 10 12 5 15 17 5 20 22 5 25 27 5 30 6 Fixed colour Colours in program 6 Code wheel 2 0 1 2 3 4 5 6 7 8 9 Colour White White Green orange blue red yellow White White white 7 Not used White light 8 Constant rotation clockwise 9 Constant rotation counter clockwise In programs 8 and 9 the speeds are equivalent to Code wheel 2 0 1 2 3 4 5 6 7 8 9 RPM 0 1 0 2 0 4 0 6 0 8 1 1 2 1 5 2 3
10. stallation Instructions annsssssnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn nnnm n nnmnnn nnmnnn 4 5 Changing lam periwivssiciviiisnncenecinisiwesansnnscinveiwesinssunseiwaeiwdeandvenssanntuedencdvinesansnuna anniennesineunneadnns 5 6 7 CHANGING MISC iia aaa e An eaaa ar aeae A aae EAEE EA E e EEA Ea aea EEE EE aE ES 5 7 DMX Stand Alone Mode for FL250 C cccccscccseeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeseeeeseneeeeeeeeeeeseeeeeeeeeaes 6 8 Control Cabling Of FL 250C ivvccisceciscscicsanceccncesenats swede weeaseveraneneiennweceusvenannuenacauederaneneuanuneusen 7 9 DMX 512 Control Features for FL 250 C ccsseeeeeeeeeeeeeneeeeeeeeeeeeeeeeeseeeeeeeeeeeeeeeeeeseeeeeeneees 8 10 Controlling the FL 250 C synchron light generators ccccccessseseeseeeeeeeeeeeeeeeeeeseeeeeeeeeees 9 11 Troubl esho ting sisson eas aeniea ao aaaea aaa aee aaaea Oaea E aeS EUa NE aaia 10 12 Spare parts and accessories ssssssnnnneenennnnnnnnnnrnnnnnnnnnnnnnnnn nn nnnnnnnnn nnn mn nnmnnn nnmnnn 11 IMPORTANT SAFETY INSTRUCTIONS Lighted lamp is HOT WARNING To reduce the risk of FIRE ELECTRIC SCHOCK EXPOSURE TO EXCESSIVE UV RADIATION OR INJURY TO PERSONS Turn OFF unplug and allow to cool before replacing bulb lamp Bulb lamp gets HOT quickly Only contact switch plug when turning ON Do not remain in light if skin feels warm Do not look directly at lighted bulb lamp Use only with bulb lamp provided by ord

Download Pdf Manuals

image

Related Search

Related Contents

Cat 5 High-Density Dual Rail LCD KVM Switch KL1508A / KL1516A  Manuale di installazione della piattaforma Business  HerboBelg_PE séminaires Paris 2012 OPTIMA Vert  ENFORCER® - Seco-Larm  Descarga pdf  Transmetteur pH/rédox 2050 e Manuel d`instructions  Design and Quality IKEA of Sweden  1771-6.5.74, Very High-Speed Counter Module User Manual  Carte Noces de Rubis  System Components  